Report T7.0) cr)a-/
City of Tigard 13 IS) S6k) lodeoh 1íc-C
III Building Division
13125 SW Hall Blvd, Tigard, OR 97223 %can
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175
www.tigard-or.gov APR2014
CITYOF icimi
Boom wimp
imm
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 13150 SW Falcon Rise Dr
City: TIGARD Zip: 97223
Owner's Name: KRISTI KIENBORTS Date: 04/04/14
Contractor's Name: SOLAR CITY CCB #: 180498
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® No OSSC or ORSC for
design requirements.
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load
Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
®
above Yes the prescriptive path.
❑ No
I:/Building/Forms/Photovoltaic-Checklist.docx 1
Is the construction
Type of• material wood and does Yes
the construction qualify If"Yes", qualifies for
Construction as "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes", qualifies for
the prescriptive path.
No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
Z Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ® Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
the prescriptive path.
Max. two layers
of composition
shingle.
Is the roof mounted
Connections of solar assembly ® Yes
the solar assembly connected to roof If"Yes", qualifies for
to the roof framing or blocking ❑ No the prescriptive path.
directly?
I:Building/Forms/Photovoltaic-Checklist.docx 2
❑ Yes If"Yes" u
Is the gauge 26 or less? , q alifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted If the spacing falls
solar systems Spacing of clamps? Minimum 24 inches
y p within 24 inches and 60
directly to inches inches, qualifies for the
Maximum 60 inches
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 1/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
I:/Building/Forms/Photovoltaic-Checklist.docx 3
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: CANADIAN SOLAR
Model Number: CS6P 250PX
Listing Agency: UL1073
4
I:Building/Forms/Photovoltaic-Checklist.docx