Loading...
Report (40) 9 .t s ri azt III City of Tigard l 76.3 aijrc, vi a Building DivisionRECEIVED 13125 SW Hall Blvd, Tigard, OR 97223 Phone: 503.718.2439 F APR TIGARD Inspection Line: 503.63 41 X03 598.1960 2014 www.tigard-or.gov CITY OF TIGAIt BUILDING DIVISION 2010 Oregon Solar Installation Specialty Check List for Prescriptive Installatiof p ty Code Installation ofRoof-Mounted PhotoVoltaic Solar Panel System Installation Address: 10763 Property Information SW RIVER DR City: TIGARD Zjp 97224 Owner's Name: Trautman, Michael Date: 04-01-201410763 SW Contractor's Name: SOLAR CITY River Dr CCB #: 180498 Design Parameters of the Property/Structure Flood Hazard Is the installation If"Yes" Located in a flood , does not Area ❑ Yes qualify for the plain/flood way? prescriptive path, follow ® No OSSC or ORSC for design re.uirements. Wind Exposure Is the wind exposure ® Yes "C"or less? If"Yes", qualifies for 0 No the prescriptive path. Installations on detached single/two-family Is the Ground Snow Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes and/or their accessory ® Yes the prescriptive path. Ground Snow Load structures. ❑ No Is the Ground Snow Installations on all Load 50 psf or less? structures other than above ® Yes If"Yes", qualifies for the prescriptive path. ❑ No I:Building/Forms/Photo Voltaic-Checklist.docx 1 Is the construction Type of material wood and does ® Yes . Construction the construction qualify If"Yes", qualifies for as "conventional light No the prescriptive path. frame"construction? • Is the spacing 24 inches or less? " Pre-engineered trusses. If Yes" q ® Yesqualifiesfor Roof framing Ci] No members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight of the PV modules and ® Yes racking less than or If"Yes", qualifies for Solar equal to 4.5 psf? ❑ No the prescriptive path. installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ NO the prescriptive path. Code? ❑ Metal RoofingSingle layer Check the type of ❑ of wood If roofing material is material roofing material shingle/shake one of the three types checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Connections of Is the roof mounted the solar tionsoassemblysolar assembly ® Yes connected to roof If"Yes", qualifies for to the roof framing or blocking ❑ No the prescriptive path. directly? I:Bui Iding/Forms/Photovoltaic-Checklist.docx 2 Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ the prescriptive path. s forNo 60 inch 115 lb spacing or less? ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? ❑ Yes If"Yes", qualifies for the prescriptive path. Attachment of ❑ No roof mounted Minimum 24 inches solar systems Spacing of clamps? If the spacing falls directly to inches within 24 inches and 60 standing seam Maximum 60 inches inches, qualifies for the metal panels prescriptive path. Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of fastener? ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Is the roof decking of WSP min. %"thickness, decking connected to ❑ Yes framing members If"Yes", qualifies for ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the solar modules module to the roof ® Yes If"Yes", qualifies for surface. ❑ No the prescriptive path. I.Bui Iding/Fonns/Photo Voltaic-Checklist.docx 3 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system rackin_ attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: GAThotAfaxt. OS' Model Number: C S - cD Listing Agency: UL1073 4 I:Building/Forms/Photovoltaic-Checklist.docx