Report (2) Is the construction Type of material wood and does Yes If"Yes", qualifies for the construction qualify Construction El No the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. 2rYeS If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for [ Yes the prescriptive path. ❑ No Is the combined weight RrYes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation ,_.,� layout in accordance �eS If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for �,�ax. two layers the prescriptive path. 12 .1\ of composition shingle. Is the roof mounted yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roofElNo the prescriptive path. to the roof framing or blocking directly? 2 1:/Building/Forms/Photo V oltaie-Checkl ist.docx ❑ YesIf"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch ,7 spacing or less? "Yes", qualifies for E] Yes I the prescriptive path. ❑ No ,:,' Minimum Up\eft rating /r of Clam ? 75 lbs for 48 incks spacing or less? ,/ If"Yes", qualifies for \\ ElYes the prescriptive path. Attachment of ,ty a No roof mounted \ {r. If the spacing falls Spacing of clamps? Minimum 24 inches within 24 inches and 60 solar systems p g p directly to inches aximum 60 inches inches, qualifies for the standing seam 1/: prescriptive path. metal panels Width of roofing / If the width of the panel panels? 18 i hes or less is less than 18 inches, inches rqualifies for the prescriptive path. ,/ Minimum�J90 at 24 / inches o'c? Size and sp "ing of If"Yes", qualifies for faste er? ❑ Yes the prescriptive path. ❑ No Is th- roof decking of WSP ` in. '/2"thickness, ❑ Yes d= king connected to "Yes", qualifies for framing members ❑ No th- prescriptive path. w/min. 8d nails @ 6"112" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the ,--�, If"Yes", qualifies for solar modules module to the roof I� Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/PhotoVoltaic-Checkl ist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: G � Model Number: 6-2,,0,2.70 Listing Agency: Ui. l-7 03 4 (:/Building/Forms/Photo Voltaic-Checklist.docx