Report (2) Is the construction
Type of material wood and does Yes If"Yes", qualifies for
the construction qualify
Construction El No the prescriptive path.
as "conventional light
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. 2rYeS If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
[ Yes the prescriptive path.
❑ No
Is the combined weight RrYes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation ,_.,�
layout in accordance �eS If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
�,�ax. two layers the prescriptive path.
12 .1\
of composition
shingle.
Is the roof mounted yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roofElNo the prescriptive path.
to the roof framing or blocking
directly?
2
1:/Building/Forms/Photo V oltaie-Checkl ist.docx
❑ YesIf"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch ,7
spacing or less?
"Yes", qualifies for
E] Yes I the prescriptive path.
❑ No ,:,'
Minimum Up\eft rating /r
of Clam ? 75 lbs for 48 incks
spacing or less?
,/ If"Yes", qualifies for
\\ ElYes the prescriptive path.
Attachment of ,ty
a No
roof mounted \ {r. If the spacing falls
Spacing of clamps?
Minimum 24 inches within 24 inches and 60
solar systems p g p
directly to inches aximum 60 inches inches, qualifies for the
standing seam 1/: prescriptive path.
metal panels Width of roofing / If the width of the panel
panels? 18 i hes or less is less than 18 inches,
inches rqualifies for the
prescriptive path.
,/ Minimum�J90 at 24
/ inches o'c?
Size and sp "ing of If"Yes", qualifies for
faste er? ❑ Yes the prescriptive path.
❑ No
Is th- roof decking of
WSP ` in. '/2"thickness, ❑ Yes
d= king connected to "Yes", qualifies for
framing members ❑ No th- prescriptive path.
w/min. 8d nails @
6"112" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the ,--�, If"Yes", qualifies for
solar modules module to the roof I� Yes the prescriptive path.
surface. ❑ No
3
I:/Building/Forms/PhotoVoltaic-Checkl ist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: G �
Model Number: 6-2,,0,2.70
Listing Agency: Ui. l-7 03
4
(:/Building/Forms/Photo Voltaic-Checklist.docx