Loading...
Report (40) Is the construction El material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. /1 Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes",qualifies for ❑ Yes the prescriptive path. n No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for r]the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for framingblockin ❑ NO the prescriptive path. to the roof or g directly? 2 I:Building/Fonns/PhotoVoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? El No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. t/z"thickness, 0 Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. 0 No 3 I:/Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SolarWorld Model Number: SW270 Plus Listing Agency: UL 1703 4 I:Building/Fonns/PhotoVoltaic-Checklist.docx , , . . , SunmoduIe.Ypj5 SW 270 mono TUV Power controlled: i TOVRh I...d E. Lowest measuring tolerance in industry --"--4 - --4- #-�- ♦- - O.t. 1 ��_' Every component is tested to meet 3 times IEC requirements 4 # ___+_ - 4.._ RELIABLE O 111 Designed to withstand heavy #.__ 4.- - 4--- —♦- Ax o4accumulations of snow and ice 10o O4 Px j 0 Sunmodule Plus: Positive performance tolerance ♦ '4 -0/*5 Wp/51 -- �. -- _ ' ._4'---- - i IP 25-year linear performance warranty and 10-year product warranty WARRANTY O World-class quality I•fed I5E 1 5 Fully-automated production lines and seamless monitoringof the process and material 5,3 d ensure the quality that the company sets as its benchmark for its sites worldwide. s SolarWorld Plus-Sorting /----N, a Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules that - us have greater than or equal to the nameplate rated power. �.../ UL 1703 25 years linear performance guarantee and extension of product warranty to 10 years /" E — ssoot SolarWorld guarantees a maximum performance degression of 0.7%p.a.in the course of ` isoo 1ao01 Certified 25years,a significant added value compared to the two-phase warranties common in the industry.In addition,SolarWorld is offering a product warranty,which has been extended to 10 years.* in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty 111 SOLARWORLD MININIMIIIIIMIIMIIMMINSEIV MADE IN USA V solarworld.com We turn sunlight into power. SunmoduIeYpi5 SW 270 mono PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)* PERFORMANCE AT 800 W/m2,NOCT,AM 1.5 Maximum power P.,.,, 270 Wp Maximum power P,",, 201.3 Wp Open circuit voltage Vp, 39.2 V Open circuit voltage Vp, 35.9 V Maximum power point voltage V,,pp 30.9 V Maximum power point voltage V,"pp 28.3 V Short circuit current 1„ 9.44 A Short circuit current I,, 7.63 A Maximum power point current I,,,, 8.81 A Maximum power point current Imo, 7.12 A 'STC:1000 W/m',25"C,AM 1.5 Minor reduction in efficiency under partial load conditions at 25°C:at 200 W/m',100% 1)Measuringtolerance(P.)traceabletoTUVRheinland:+/-2%(TUVPowerControlled). (+/-2%)of the STC efficiency(1000W/m')isachieved. COMPONENT MATERIALS THERMAL CHARACTERISTICS NOCT Cells per module 60 46°C Cell type Mono crystalline TC/s 0.004%/K Cell dimensions 6.14 in x 6.14 in(156 mm x156 mm) TC v., -0.30%/K Front Tempered glass(EN 12150) TCPmpo -0.45%/K Frame Clear anodized aluminum Operating temperature -40'C to 85°C Weight 46.7 lbs(21.2 kg) SYSTEM INTEGRATION PARAMETERS Ix moo W/m2 Maximum system voltage SC II 1000 V Max.system voltage USA NEC 600 V 800 W/m' Maximum reverse current 16 A F. 600 W/ma Number of bypass diodes 3 E UL Design Loads' Two rail system 113 psf downward V 64 psf upward 400 W/m' UL Design Loads' Three rail system 170 psf downward 64 psf upward 200 W/m= I113 psf downward IEC Design Loads' Two rail system 100 Wm'/ 50 psf upward ` 'Please refer to the 5unmodule installation instructions for the details associated with these load cases. Module voltage[VI V« ADDITIONAL DATA rx4 37.44(951) Power sorting' -OWp/+5Wp J-Box 1P65 NM Connector MC4 11.33(288) Module efficiency 16.10% Fire rating(UL 790) Class C • -r 0.6 15.3 41.30(1050) VERSION 2.5 FRAME • Compatible with both"Top-Down" Version and"Bottom"mounting methods 2.5 frame 65.94(1675) —bottom ;,,, n • ♦Grounding Locations: mounting -4 corners of the frame LI holes -4 locations along the length of the module in the extended flanges INENUMMI 0 0 0 0 0 0 0 0 NEYr!a,, ---x4 Independently created PAN files now available. .- I 1 1 4.20(107) Ask your account manager for more information. --11--) �.�I[ 1.22( ) F 39.41(1001) 1 All units provided are imperial.SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-6004U5 08-2013 Enphase®M215 Microinverter//DATA INPUT DATA(DC) M215-60-2LL-S22/523 and M215-60-2LL-S22-NA/S23-NA(Ontario) Recommended input power(STC) 190-270 W Maximum input DC voltage 45 V Peak power tracking voltage 22-36 V Operating range 16-36 V Min./Max.start voltage 22 V/45 V Max. DC short circuit current 15 A Max. input current 10.5 A OUTPUT DATA(AC) @208 VAC @240 VAC Rated(continuous)output power 215 W 215 W Nominal output current 1.0 A (Arms at nominal duration) 0.9 A(Arms at nominal duration) Nominal voltage/range 208/183-229 V 240/211-264 V Extended voltage/range 179-232 V 206-269 V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 57-60.5 Hz 57-60.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles; 1.04 Arms over 5 cycles EFFICIENCY CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted,reference EN50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes, reference EN50530) 99.3% Night time power consumption 46 mW MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8"x 6.45"x 1.0")without mounting bracket Weight 1.6 kg(3.5 lbs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor- NEMA 6 FEATURES Compatibility Pairs with most 60-cell PV modules Communication Power line Monitoring 1 ree lifefili�e .nitoring via Enlighten software Compliance UL1741/IEEE15, FCC Part 15 Class B CAN/CSA-C 2.2 NO.0-M91,0.4-04,and 107.1-01 To learn more about Enphase Microinverter technology, ] enphasea visit enphase.com ENERGY ©2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. • SoLARMOuNT Technical Datasheets :ES U NI RAC SolarMount Beam Connection Hardware SolarMount L-Foot Part No, 304000C, 304000D • L-Foot material: One of the following extruded aluminum alloys:6005- T5,6105-T5,6061-16 • Ultimate tensile:38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized L-Foot weight:varies based on height:—0.215 lbs(98g) Allowable and design loads are valid when components are Bea ' ;,r assembled with SolarMount series beams according to authorized „. #` Bolt UNIRAC documents 1 I L-Foot • For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one ''" errated ASTM F594%"serrated flange nut Flange Nu •Use anti seize and tighten to 30 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-partytest y results from an IAS accredited laboratory A NOTE: Loads are given for the L-Foot to beam connection only; be ►X sure to check load limits for standoff,lag screw,or other attachment method IN Applied Load Average Safety Design Resistance 3"'"01°"° Direction Ultimate Allowable Load Factor, Load Factor, "`iLrafnmAPT lbs(N) lbs(N) FS lbs(N) 0 ' Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664