Report (41) i cgt—ie 54) City s Of Tigard , _ Building ivision a 13125 SW Hall Blvd, Tigar , OR 97223 ('' ) TIGARD Phone:503.718.2439 Fax: 03.598 1960 Inspection Line: 503.639.4175 ' www.tigard-or.gov , • 2010 Oregon Solar Installation Specialty Code . Check List for Prescriptive Installation oofRoof-Mounted PhotoVltaic Solar Panel Syst Property Information Installation em Z' i Owner's • e: t c ••. - - --"- Date:* c Contractor's Name: SolarCity Corporation CCI3 : Design Paramet # 180498 ers of the Property/Structure ------------'' ' "Yes" does not Is the installation i qualify for the Flood Hazard 8 Yes Located in a flood ' prescriptive path, follow Area piain/tlood way? .., No OSSC or ORSC for desi z. re.tlirenients, Is the wind exposure I f"Yes" qualifies for Wind Exposure l' "C"or less? 0 No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Yes / the prescn'ptive path. and/or their accessory / Ground structures. 0 No Snow Load Is the Ground Snow I Load 50 psf or less? . I Installations on all structures other than XYes If"Yes", qualifies for /the prescriptive path. above 0 No 1/Bodding/Forms/Photo Voitalc-Checklist docx Is the construction ir Yes material wood and does • Type of If"Yes", qualifies for the construction qualify Construction No the prescriptive path. as "conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. E Yes If"Yes", qualifies for the prescriptive path. No Roof framing members Is the spacing 24 inches or less? Nominal lumber. Yes If"Yes", qualifies for the prescriptive path. n No Is the combined weight C Yes of the PV modules and If"Yes", qualifies for racking less than or No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of E No the prescriptive path. the 2010 Oregon Solar Code? Li Metal Single layer If roofing material is Roofing Check the type of P of wood one of the three types material roofing material shingle/shake checked, qualifies for the prescriptive path. Max. two layers sohficongmleposition Is the roof mounted Connections of solar assembly Yes the solar assembly connected to roof — If"Yes",qualifies for No the prescriptive path. to the roof framing or blocking directly? 2 liBuilding/Forms/PhotoVoltaic-Checklist.docx [] Yes If"Yes", qualifies for Is the gauge 26 or less? No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for El Yes the prescriptive path. / No Minimum Uplift rating , of Clamps? 75 lbs for 48 inches spacing or less? , If"Yes", qualifies for E} Yes the prescriptive path. yr No Attachment of roof mounted Minimum24 iIf the spacing falls solar systems inches Spacing of clamps? within 24 inches and 60 inches inches, qualifies for the directly to Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel \A CI\ 1 panels? ' inches Minimum um l8 inches or less I nim #10 at 24 inches o/c? is less than 18 inches, qualifies for the prescriptive path. Size and spacing of — If"Yes", qualifies for G fastYes faster? — the prescriptive path. O'L) [ - No Is the roof decking of — WSP min. '/2"thickness, .__. Yes decking connected to If"Yes", qualifies for framing members f] No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? 1 Is the height less than or Maximum 18 inches equal to 18 inches? . Height of the from the top of the If"Yes", qualifies for 0.. Yes solar modules module to the roof the prescriptive path. surface. C No 3 11Building/Forms/PhotoVoltaic-Checklist.docx ____ • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: ---10 ‘t\ SOes-q_ - Model Number: ;3-5 D 4VO5 K Listing Agency: UL1703 4 liBuilding/Forms/PhotoVeltaic-Checklistdocx