Loading...
Plans (66) CITY OF TIGARD ECI Approved „. [t]------ PROJECT INFORMATION Conditionally Approved [ ] JAN 2 2 2.014 See Letter to:Follow [ ] OWNER LE RESIDENCE CONTRACTOR ADVANCED ENERGY SERVICES I Attached ` ;y p 10733 SW LADY MARION DRIVE 14755 SE 82ND DRIVE �T {, r ,-, k`^'IT� ° +�j"` �J TIGARD.OR 97224 CLACKAMAS,OR 97215 Perilllt lv ♦��ir I, F. v MAIN: CT:RON 5-0117 Addre s: ' Kiri L�i11�►�����j �� >,• BUILDING DIVISION BUILDING SINGLE FAMILY RESIDENTIAL CONTACT: -E0BURDEN DATA PHONE:503.606-3719 By: '�i, ,a NM■` ROOF SPECS ASPHALT COMPOSITION ROOF /��/�y//� e J I d ` •j=,l APPLICABLE 2010 OREGON SOLAR INSTALLATION W/2X6 TRUSSES DOUGLAS FIR#2`24'O.C. '` "'�' et ` CODES SPECIALTY CODE 0 VL' �1��> ,. ROOF TILT:32 DEGREES I 1" AZIMUTH:175 DEGREES i SYSTEM SOLARWORLD270W � � b E.J' on job 3?.q ' (12 MODULES) ROOF AREA(PLAN VIEW).2,490 SF i (12)X 270W.3.24kW ARRAY AREA. 226 SF, ARRAY IS<25%OF ROOF AREA .`II • (12)ENPHASE M250 INVERTERS MODULE O DEC9 SPECS SUNMODULE SW 270W OFFICE�CO J 1 INVERTER AT EACH MODULE \v/ 8 (L)66'X(W)39.5'X(H)1.34'WEIGHT:47.6'LBS '{ COMBINED WEIGHT OF MODULES AND RACKING IS< � ❑ _ 4,5 PSF. i' PROJECT NOTES i i �� I _ 303.2.PV SYSTEMS AND SUPPORTING STRUCTURE �m'nEna 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED ..-MLN PANEL SHALL COMPLY WITH REQUIREMENTS OF OSSC WOOD CONSTRUCTION WITH 2X6 TRUSSES AT 24"O.C. Area of Work • CHAPTER 6 OR THE ORSC AS APPLICABLE. MAX.EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS PV array owvtwev i 2. 303.3.ALL PV MODULES TO BE UL 1703 LISTED, IN TABLE 305.4.1. 3. 303.5-PV SYSTEM SHALL HAVE A FIRE 8. 304.9.5-DISCONNECTS,3-BOXES,COMBINER BOXES OR • CLASSIFICATION THAT IS EQUAL TO OR GREATER GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED THAN THE ROOF ASSEMBLY REQUIRED BY OSSC PATHWAY OR CUTOUT. F j SECTION 1505.1, 9. ROOF MATERIAL IS ASPHALT COMPOSITION ROOF, 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE 10, PER 305.4 ITEM 3:TOTAL SYSTEM WEIGHT SHALL NOT RATED FOR THEIR USE, EXCEED 4,5 PSF.PV MODULES AND RACKING SHALL BE SW LADY MARION DRIVE 5. 303.4.304.8-PV LAYOUT SHALL NOT RESTRICT DIRECTLY ATTACHED TO ROOF FRAMING AS SHOWN IN EGRESS,LIGHT,VENTILATION,OR ROOF DRAINAGE CONNECTION DETAIL*2.ATTACHMENT SPACING WILL REQUIREMENTS. BE 48"O.C.MAX,AND WHEN ATTACHMENT LOCATED 6, 304.9.1 GENERAL PATHWAY REQUIREMENTS- WITHIN 3'OF ROOF EDGE,HIP,EAVE,RIDGE SHALL BE AOI N1,1:ON STRUCTURES AL WITH A PV ARRAY MAX MAX. ------ AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF 11, MAMODULE HEIGHT<12"OFF ROOF SURFACE. �, WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN 12. SECTION 304.7-MECHANICAL EQUIPMENT f INTERSECTING ADJACENT ROOF AND WHERE NO CLEARANCES:NOT APPLICABLE,THERE IS NO 1 SECTION IS LARGER THAN 150 FEET MEASURED IN MECHANICAL EQUIPMENT WITHIN OR ADJACENT TO LENGTH OR WIDTH. AREA OF WORK, p EXCEPTION IA:WHERE PV ARRAY DOES NOT EXCEED fgR 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A MINIMUM OF 12" UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED ' ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. NORTH (11) 1. SITE PLAN ADVANCED ENERGY SERVICES DATE, JANUARY 17,2014 PROJECT it; LE scale: 1" . 30'-0" 14755 SE 82ND DRIVE o' is 30' so' CLACKAMAS,OR 97015 LE RESIDENCE 503-635-0117 10733 SW LADY MARION DRIVE CCB#180882 TIGARD,OR 97224 � ;Ei, DWG. 1 OF 3 . . ) 4V-3ilAYI "4...;•2C-1'..4l',. T<;? _ OF A ROOF .. .;":7, a ) T siG�. , 2X6 ROOF TRUSS 024'D.C. TYP.---- ' -,...0. , , .N1/4 I' . EXISTING ROOF , 1 i . . I ji 1 1 .___,../I ail i , io...__A 1 I____ ..........,--.00 ••- ---„,---00 ••• 1 - " -- , r"--4--,-- , 1 SKYLIGHT,Ty,. I , i .z.' , , , \ ____.. i , I 1 1 1 \ • 1 0 1 1 I 1 1 i I 1 1 1 I , , I i I I 1 SOLAR , ARRAY , I , t l I I I I l—_1 L__1,1 • I 1 1 ) I I / I 1 i 1 j 1 1 I 1 1 / j I 1 1 i I i I i ' 4 I 1 I 1 i 1 I I 1 ' I 4 4De ,/ I I 1 i 1 i , 1 i 1 I / I I ()11' • , , I I I I 1 IP 1 I T 1 i I CONNECTION ATTACHMENT / , T01 ROOF RAtLS,TYP, I ( TtUSS,TYP. . r r / SUNEVE , READING,lYP. ' , / . I , r I I / REFER TO DRAWING 3 • FOR ROOF SECTION,TYR. Area of Work N ADVANCED ENERGY SERVICES DATE: JANUARY 17, 2014 IPROJECT#: LE 1. ENLARGED ROOF PLAN - 14755 SE 82ND DRIVE Scale: 1/4".1.0 CLACKAMAS,OR 97015 LE RESIDENCE 503-635-0117 10733 SW LADY MARION DRIVE CCB#180882 TIGARD,OR 97224 DWG. 2 OF 3 SOLAR COLLECTOR MODULE MODULE(4.5 PEE,MAX,) DIMENSI•N VARIES I .2tiiigiiiiigii:.i:iiiiiitiiiiiiiiiiii tiiii:i: ••...••.•••4 ••••••4.0.••••• MODULE DIMENSION .•, •`.:4 OM•v•••V IC'MAX SECTION A :11%.1'i}r vow' 17:Xi:vi' ,i' :::vis l SECTION A 'I,'f I:f:i.••••.•.• •e '�I CONNECT SOLAR MODULE TO 1':•.i• ''I RAILS WITH 1 CONNECTOR •� •I FOR EACH 8.SO FT.OR %;;:} LESS OF MODULE SURFACE i1 io CORROSION RESISITANT K.i};: EQUIPMENT SCHEDULE/NOTES: Le Residence NEC PV LABELING REQUIREMENTS (7)PVARRAY,1250LARWORLD'170WMODULES (2)EACH MODULE CONNECTED TO ONE M255 ENPHASE MICRO-INVERTER 13.24 kW Solar PV System ( )( ) II 10AWGMICRO-BARE COPPERERS EGC E UP ONE PHASE CIRCUIT. AC CIRCUIT BREAKER:NEC 705.12 D 7 &690.54 (3)10 AWG BARE COPPER EGC ENPHASE MZSO NOUTPUT F WIRES (4)SOLADECK ROOFTOP JUNCTION BOX.TRANSITION TO THWN-2 AWG CONDUCTORS WARNING:CIRCUIT BREAKER IS ENERGIZED FROM (5)ENPHASE ENVOY DATA MONITORING DEVICE PV Array (12) Solarworld SW 270 Watt PV Modules TWO SOURCES-SOLAR SYSTEM AND UTILITY GRID, (6)UTILITY GRADE METER TO MEASURE PV OUTPUT LOCATED IN GARAGE ADJACENT TO MAIN PANEL (7)GRID INTERCONNECTION BY ISA TWIN TWO POLE BREAKER (1)(2) MAIN SERVICE PANEL 705.12(0)(4) (8)200A THOMAS&BETTS SERVICE PANEL LOCATED IN GARAGE WITH 2O0A MAIN BREAKER o l7 O O D D CO 1:1001:71 (9)UTILITY METER LOCATED ON EXTERIOR WEST WALL OF GARAGE POINT OF CONNECTION (10)GROUNDING ELECTRODE CONDUCTOR CONNECTED TO AC SOLARPOI ELECTRIC SYSTEM EXISTING BUILDING GROUNDING ELECTRODE. AC OUTPUT CURRENT:12A NOTES: NOMINAL AC VOLTAGE:240V -THE SUM OF THE RATINGS OF BREAKERS FEEDING ANY PANEL MUST NOT EXCEED 120%OF THE RATING OF THE PANEL BUS BARS WARNING NEC 705.12(D)(2) INVERTER OUTPUT CONNECTION /31 DO NOT RELOCATE THIS OVERCURRENT DEVICE AC Voltage Drop Calculation 11 // 10 AWG USE-2/RHW-2 1,Internal Voltage drop within cabling:12 micro.inverters=.36% Nip Sunlight Resistant Wire plus THIS PANEL IS FED BY TWO SOURCES OF POWER 2.Voltage drop from OCPD to Main Service Panel One#6 AWG Bare Copper EGC 1-UTILITY 2-PV INVERTER %Vdrop=(1A.12).(2•4oft) =(9601.00124ohms/ft))/240V =0.00496•100 =0.50%AC Voltage Drop PRODUCTION METER(ETO PV REQUIREMENT 2.7.3) TOTAL AC VOLTAGE DROP:0.50%+0.36%=0.86% CUSTOMER OWNED SOLAR GENERATOR OUTPUT (4)SolaDeck Junction Box -- — -- -- House Exterior House Interior — --- --- --- - Project:10733 SW LADY MARION DR Approximate distance from TIGARD,OR 97224 roof top array to Main Electrical Panel is 40 feet. 3.24 kW SOLAR PV SYSTEM 3/4"EMT with (2)#10AWG Solar Contractor: 10-3 MC from Output meter TH W N-2 conductors w/(1)a 10 P THWN-2 Neutral and(1)010 EGC to Main Electrical Panel. Conduit runs through attic and down chase Distance less than 10'. 200A Main Panel Advanced Energy Services to main electrical panel located in garage. 77p�o / PV (8) Production Meter Utility Meter 120/240 Volt, Title: three-wire,single-phase Single Line Diagram,Grid Tied Solar PV System 1 Utility (10) DATE:1/7/14 DRAWN BY:Ron Burden r 1 (7) """ T PROJECT/Customer Name: — �� 4 �I� (9) Envoy 15A Tw)nTwo Grounding Drawing#:1 Le Residence (5) (6) Pole Backfeed Bkr '"""""''" ""' """""""""""""""""""""""""'"-""" Electrode REVISION HISTORY DATE NOTES #6 bare copper GEC