Specifications (10) /14 5t (3 —cc�j RECEIVED 4.4 05-70 sGcJ JUN 10 2013 JDlaIgt y CITY OFTIGARD BUILDINGDIVISION 3055 Clearview Way San Mateo,CA.94402 (8881 SOL-CITY(765-24891 www solarcity.com April 23,2013 Project/Job#9721441 RE: COVER LETTER Project: Pugsley Residence 10570SW Park St Tigard,OR 97223 To Whom It May Concern, A jobsite survey of the existing framing system was performed by an audit team from SolarCity. The attached structural calculations are based on site observations and design criteria listed below: Design Criteria: -Applicable Codes= 2010 OSISC&2010 OSSC,ASCE 7 05,and 2005 NDS -Roof Dead Load = 7 psf(All MPs) -Roof Live Load = 20 psf(All MPs) -Ground/Roof Snow Load = 25 psf - Risk Category= II,Wind Speed = 95 mph, Exposure Category C -Solar modules =As indicated in attached drawings. On the above referenced project,the structural roof framing has been reviewed for loading from the PV system on the roof.The structural review, including the plans and calculations only apply to the section of roof that is directly supporting the PV system and its supporting elements.After review it was determined that the existing structure requires a structural upgrade.The required upgrade is shown in the structural drawings on the SolarCity drawing set. The structural roof framing including the specified upgrades and the new attachments that directly support the gravity loading from PV modules have been reviewed and determined to meet or exceed requirements of the 2010 OSISC&2010 OSSC. Please contact me with any further questions or concerns regarding this project. Sincerely, ��q�ED PROFF G ' Ne 4kr Yoo Jin Kim, P.E. Civil Engineer Q '9 Main: 888.765.2489,x5743 email: ykim@solarcity.com loNsso%4:4:70R;•3': tEXPIFISt JUNE XL...u►U' Digitally signed by Yoo Jin Kim Date:2013.04.23 16:12:23-07'00' *i� 04.23.2013 Version# 10.4 SolarCity SleekMountT'" Calculator PROJECT INFORMATION Project Name: Pugsley Residence AHJ: Tigard Job Number: 9721441 Building Code: 2010 OSISC&2010 OSSC System Size: 6.860 kW PV System Pugsley,Camie L Based On: 2009 IBC/IRC Customer Name: ASCE Code: ASCE 7 05 Address: 10570 SW Park St Tigard Upgrades Req'd? Yes City/State: OR Stamp Req'd? Yes Zip Code 97223 45.441080 PV Designer: Luis Robles Latitude: Calculations: Yoo Jin Kim, P.E. Longitude: -122.775048 Reviewer: Yoo Jin Kim, P.E. SC Office: Portland EOR: Yoo Jin Kim, P.E. MOUNTING STRUCTURE & PV SYSTEM INFORMATION Mounting Structure Information Risk Category II Framing Type Stick Frame PV System Type SolarCity SleekMountT" Roofing Material Comp Roof Tile Reveal Tile Roofs Only NA Roof Slope 180 Rafter Spacing 24"O.C. PV System Information PV Module Trina Solar TSM-245PC Total Number of Modules 28 PV Module Orientation Landscape Spanning Vents No Total Area of Array 493 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C Minimum Eave End Setback 12" Minimum Ridge Setback 12" Spanner Bar Direction Tile Roofs Only NA Optimal Standoff Y-Spacing Tile Roofs Only NA 2 5 psf PV System Weight PV Module Weight Hardware Assembly Weight 0.5 psf Total PV Module&Assembly Weight 3 psf SEISMIC CONSIDERATIONS Seismic Design Criteria (per USGS) Seismic Design Code ASCE 7-05 Latitude 45.4411 Longitude -122.7750 SRA at Short Period Ss 0.971 USGS SRA at is Period S1 0.347 USGS Soil Site Class D IBC 1613.5.2 Seismic Design Category SDC D USGS Seismic Check Required(Ss>_ 0.4q&SDC D)? Yes IBC 1613.1 ALTERATION LATERAL DESIGN 10% EXCEPTION CHECK, PER IBC SECTION 3404.4 Weight of Proposed PV System Area Dead Load Weight PV System Weight 493 sf 3 psf 1479 lbs Total Weight of PV System Wa 1479 lbs Weight of Roof on Existing Building Sum Area of MPs with PV 1033 sf Portion of Roof Weight Area Dead Load Weight Roof 1,033 sf 7.0 psf 7,233 lbs _ Ceiling 1,033 sf 7.0 psf 7,233 lbs Interior Walls(Top Half) 514 sf 6.0 psf 3,086 lbs Exterior Walls(Top Half) 514 sf 11.0 psf 5,658 lbs Net Weight of Roof Under PV W(exist) 23,211 lbs Check%Increase of Roof Weight/ Seismic Shear Load %Increase of DCR of Lateral 6.4% IBC Sect. Force Resisting System W("v)/M@"inq Increase Seismic Shear Load<10%,-> [GOOD] 3404.4 Note: Seismic base shear is directly proportional to roof weight. • CALCULATION OF DESIGN WIND LOADS Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Least Horiz. Dim.of Building LHD 37 ft Effective Roof Slope 18° Effective Rafter Spacing 24"O.C. Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Roof Wind Zone Width a 4 ft Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Section 6-3 Topographic Factor Ka 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Section 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 16.7 psf Wind Zone Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) Ext. Pressure Coefficient(Up) GC,(Up) -0.9 -1.6 -2.5 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) GCp(Down) 0.5 0.5 0.5 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GCP) Equation 6-22 Wind Pressure Up P(up) -14.6 psf -26.3 psf -40.9 psf Wind Pressure Down P(down) 10.0 psf 10.0 psf 10.0 psf COMP ALLOWABLE ATTACHMENT SPACING (IN.)AND TRIBUTARY AREA (FT^2) Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) Max Allowed Foot X-Spacing Landscape 48" 48" 48" Max Allowed X Cantilever Landscape 24" 24" 20" Max Standoff Tributary Area TribCL 13 sf 13 sf 13 sf PV Assembly Dead Load WPV 3 psf 3 psf 3 psf DLPV PCL 39 lbs 39 lbs 39 lbs WLUP-0.6 DLPVcos(9) TCL -168 lbs -320 lbs -510 lbs Attachment Uplift Capacity Tallow 637 lbs 637 lbs 637 lbs TCL/Tallow DCRLand 26.3% 50.2% 80.0% CALCULATION OF ROOF DEAD AND LIVE LOADS Roof Dead Load Material Load Roof Category Description All MPs Roofing Material Comp Roof 2.5 psf # Layers(Comp Roof Only) 1 Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None 0.0 psf Rafter Size and Spacing 2 x 6 @ 24 in.O.C. 1.1 psf Vaulted Ceiling No 0.0 psf Miscellaneous Miscellaneous Items 1.4 psf Total Roof Dead Load 7 psf(All MPs) 7.0 psf Reduced Roof Live Load Symbol Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 4/12 Tributary Area Reduction R1 1 Section 4.9 Sloped Roof Reduction R2 1 Section 4.9 Reduced Roof Live Load Lr 4= Lo(R1)(R2) Equation 4-2 Reduced Roof Live Load Lr 20 psf(All MPs) 20.0 psf Ceiling Dead Load Material Load Ceiling Joist Size and Spacing 2 x 6 @ 16 in.O.C. 1.7 psf Insulation Yes 1.4 psf - Finish 1/2"Gypsum Board 2.2 psf Miscellaneous Miscellaneous Items 1.7 psf Total Ceiling Dead Load 7.0 psf Interior Walls Material Load Finish(Side A) 1/2"Gypsum Board 2.2 psf Wall Studs 2 x 4 @ 16 in.O.C. 1.1 psf Insulation No 0.0 psf Finish(Side B) 1/2"Gypsum Board 2.2 psf Miscellaneous Miscellaneous Items 0.5 psf Total Interior Wall Load 6.0 psf Exterior Walls Material Load Exterior Finish Wood Siding 5.0 psf Wall Studs 2 x 4 @ 16 in.O.C. 1.1 psf Insulation Yes 1.4 psf Interior Finish 1/2"Gypsum Board 2.2 psf Miscellaneous Miscellaneous Items 1.3 psf Total Exterior Wall Load 11.0 psf • GROUND/ROOF SNOW LOADS Ground Snow Load Effective Roof Slope 180 Ground Snow Load pg 25.0 psf ASCE Table 7-1 3 Snow Load Reductions Allowed? No Code Design Roof Snow Load Over PV Modules Ps-pv 25.0 psf Design Roof Snow Load Over Surrounding Roof Ps-roof 25.0 psf • COMPANY PROJECT S'I WoodWorks® 30 5Clety Corporation 9721441-Pugsley 3055 Clearview Way MP1A.wwb San Mateo,CA 94402 SOFTYARI FOR WOOD DESIGN Apr.23,2013 16:03 Design Check Calculation Sheet Wood Works Sizer 9.21 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End DL Dead Full Area No 7.00 (24.0)* psf SL Snow Full Area Yes 25.00 (24.0)* psf PV1 Dead Point No 4.42 20 lbs PV2 Dead Point No 7.75 39 lbs PV3 Dead Point No 11.00 20 lbs PV4 Dead Point No 14.33 39 lbs *Tributary Width (in) Maximum Reactions(lbs), Bearing Capacities (lbs)and Bearing Lengths(in) : 18'-8.5" 15'-3.9" 3'-1.7" 0 3' 17'-7" Unfactored: Dead 218 Snow 528 160 359 Factored: Total 747 - Bearing: 518 F'theta 667 Capacity 667 Joist 1752 Supports 1055 1001 Anal/Des 1055 Joist 0.43 Support 0.71 0.52 Load comb 0.49 Length 0.50* 0* Min req'd 0.50* 0.50* Cb 1.75 0.50* Cb min 1.75 1.00 Cb support 1.13 1.00 Fcp sup 625 1.13 625 *Minimum bearing length setting used: 1/2"for end supports and 1/2"for interior supports Lumber n-ply,D.Fir-L,No.2,2x6,2-ply(3"x5-1/2") Supports:All-Timber-soft Beam,D.Fir-L No.2 Roof joist spaced at 24.0"c/c;Total length: 18'-8.5";Pitch:4.0/12; Lateral support:top=full,bottom=at supports;Repetitive factor:applied where permitted(refer to online help); WARNING:Member length exceeds typical stock length of 18.0[ft] Analysis vs.Allowable Stress(psi)and Deflection(in)using NDS 2005: Criterion Analysis Value Design Value Analysis/Design Shear fv = 45 Fv' = 207 fv/Fv' = 0.22 Bending(+) fb = 1484 Fb' = 1547 fb/Fb' = 0.96 Bending(-) fb = 231 Fb' = 1547 fb/Fb' = 0.15 Live Defl'n 0.81 = L/228 1.02 = L/180 0.79 Total Defl'n 1.19 = L/155 1.54 = L/120 0.77 WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN MP1A.wwb WoodWorks®Sizer 9.21 Page 2 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cf rt Ci Cn LC# Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 4 Fb'- 900 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S, V = 526, V design = 498 lbs Bending(+) : LC #4 = D+S (pattern: sS), M = 1870 lbs-ft Bending(-) : LC #2 = D+S, M = 291 lbs-ft Deflection: LC #4 = (live) LC #4 = (total) Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASCE 7-05 / IBC 2009 CALCULATIONS: Deflection: EI = 33e06 lb-int/ply "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection. Design Notes: 1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the National Design Specification(NDS 2005), and NDS Design Supplement. 2.Please verify that the default deflection limits are appropriate for your application. 3.Continuous or Cantilevered Beams:NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5.SLOPED BEAMS:level bearing is required for all sloped beams. 6.The critical deflection value has been determined using maximum back-span deflection.Cantilever deflections do not govern design. ' i P O R T E MEMBER REPORT Level MP18 PASSED 1 pieces) 2 x 6 Douglas Fir-Larch No. 2 @ 24"OC Oman Sloped Langer 14'13418' �._ ���. . .0 0 12 ,. t it IF 4' vu.. I. T D x IR All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results Actual CO Location Allowed Result LDF Load:Combination(Pattern) System:Roof Member Reaction(lbs) 589 @ 3' 2352(3.50") Passed(25%) -- 1.0 D+1.0 S(All Spans) Member Type:Joist Shear(lbs) 357 @ 3'6 15/16" 1139 Passed(31%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential Moment(Ft-lbs) 847 @ 8'1/8" 975 Passed(87%) 1.15 1.0 D+1.0 S(Alt Spans) Building Code:IBC Live Load DeFl.(in) 0.335 @ 8'1" 0.527 Passed(L/377) -- 1.0 D+1.0 S(Alt Spans) Design Methodology:ASD Total Load Dell.(in) 0.492 @ 8'1" 0.703 Passed((/257) -- 1.0 D+1.0 S(Alt Spans) Member Pitch:4/12 •Deflection criteria:LL(1./240)and TL(1./180). •Overhang deflection criteria:LL(21/240)and TL(21./180). •Bracing(Lu):All compression edges(top and bottom)must be braced at 7'2 9/16"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. •A 15%increase in the moment capacity has been added to account for repetitive member usage. •Excessive upward deflection has occurred at the end of the overhang. •Applicable calculations are based on NDS 2005 methodology. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Snow Total Accessories 1-Beveled Plate-SPF 3.50" 3.50" 1.50" 166 422 588 Blocking - 2-Beveled Plate-SPF 3.50" 3.50" 1.50" 108 249 357 Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Dead Snow Loads Location Spacing (0.90) (1.15) Comments 1-Uniform(PSF) 0 to 13'2 1/2" 24" 7.0 25.0 Roof — 2-Point(Ib) 4'5" N/A 20 - PV DL 3-Point(lb) 7'9" N/A 39 - PV DL 4-Point(lb) 11' N/A 20 - PV DL Member Notes Section B Weyerhaeuser Notes (Z3)SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator ' Forte Software Operator Job Notes 4/23/2013 4:08:43 PM voo Jin Kim I one v4.0, Design Ermine:V5.6.1.203 SolarCity (650)963 5100 x 5743 972144-1.47 F. ',. ykim@solarcity.com Page 1 of 1 el FV R T E MEMBER REPORT Level,MP2 PASSED • 2 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 24" OC Omni Sloped Length:tf 2 31r + + ,1. 0 a, 0 r * .. r rr ' ,1 it.1T x 1 All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Roof Member Reaction(lbs) 698 @ 3' 4704(3.50") Passed(15%) -- 1.0 D+1.0 5(All Spans) Member Type:Joist Shear(lbs) 446 @ 3'6 15/16" 2277 Passed(20%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential Moment(Ft-lbs) 1216 @ 9'4 15/16" 1950 Passed(62%) 1.15 1.0 D+1.0 S(Alt Spans) Building Code:IBC Live Load Defl.(in) 0.360 @ 9'3/4" 0.632 Passed(1/421) -- 1.0 D+1.0 S(Alt Spans) Design Methodology:ASD Total Load Defl.(in) 0.516 @ 9'1 1/4" 0.843 Passed(L/294) -- 1.0 D+1.0 S(Alt Spans) Member Pitch:4/12 •Deflection criteria:LL(L/240)and TL(1/180). •Overhang deflection criteria:LL(21/240)and TL(21/180). •Bracing(Lu):All compression edges(top and bottom)must be braced at 16'3/8"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. •A 15%increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS 2005 methodology. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Snow Total Accessories 1-Beveled Plate-SPF 3.50" 3.50" 1.50" 229 469 698 Blocking 2-Beveled Plate-SPF 3.50" 3.50" 1.50" 133 301 434 Blocking - •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Dead Snow Loads Location Spacing (0.90) (1.15) Comments 1-Uniform(PSF) 0 to 15'2 1/2" 24" 7.0 25.0 Roof 2-Point(Ib) 6" N/A 20 - PV DL 3-Point(Ib) 3'10" N/A 39 - PV DL 4-Point(lb) 7 1" N/A 20 - PV DL 5-Point(Ib) 10'5" N/A 39 - PV DL 6-Point(Ib) 13'8" N/A 20 - PV DL Member Notes Section B Weyerhaeuser Notes ( /� �)SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator • Forte Software Operator Job Notes 4/23/2013 1:09:25 PM Yoo Jin Kim I orte v4.0,Design Engine:V5.6.1.203 SolarCity (650)9635100 x 5743 97?144-1.411- ykim@solarcity.com Page 1 of 1