Plans (38)
Aik Ur • General Notes: G..„0'"" Wel Chemical Suppression 1.System Design and maintanance to be in accordance with TO MANUAL NFPA 17A,96,any other applicable NFPA standards as RELEASE I SIBLE required for a particular application and design and KIDDE TOFU LINKS 1 FIRE SYSTEMS Manual P/N 87-122000-001 I AM 2. This drawing shows protection of the appliances,plenum and duct. Ili 0 b0 3.Agent cylinder to be located next to hood.Alternative ELECTRIC SHUTDOWN---,-,,, HFF locations acceptable within the design limitations of the PLUG' j;�''�' system. 0 - - all, i 4.All piping will be schedual 40 black and securly fastened. • �� 6.Manual Release shall be located a minimum of 10'and a ,/ , 0 1t") maximum of 20'from the kitchen exhaust system at 48"off 0 >,, •*••-. ground level. t ‘ __ O 7.Exhaust air shall remain on and make up air shall shut down during discharge, }o.{ O ri 8.Upon discharge all sources of fuel and power to all appliances and outlets located under the hood shall be shut til C ' C) tri *4 down s) 9.Fusible link to be located above each appliance and below 0 :: 0g duct 10.Electrical connections shall not be made inside XV ® control head f Bill Of Materials . N Item Qty Part Number Description {'�1 m 1 1 87-120006.001 WHDR-400M Cylinder(4 Gal-12 Flow Points) *V 2 1 83-844908-000 Discharge Adapter Kit HAZAt1DIMENSIONS&NOZZLE CHART 3 1 60-9196984-000 Vent Plug APPLICATION NOZZLE HEIGHT SIZE NOZZLE QUANTITY FLOW COUNT _ 4 1 87-100013-001 Shelf Bracket,4 Gal M Cyl HOOD 10'max length 8'-0" ADP I i H U S E 5 1 87-120099.001 XV Control System 6 1 87-120045-001 High Pressure Hose 7-112" DUCT Sates 8 Service Inc. 9 ( ) 0-6"inside 18"ROUND ADP 2 2 Portland,OR 7 115031248-1948 WK-875572-000 Mechanical Remote Manual Release OPEN RANGE 13"to 48' 2 BURNERS R 1 1 GCB 116821 8 1 87-120014-001 R Nozzle GRILL 13"to 48° 36' ADP 1 1 ,. 9 4 87-120011-001 ADP Nozzle l38I5 Gyro's FRYER 27.5°to 45" 14 x 21 F 1 2 { '°'• 13815 SW Pacific Hwy 10 3 60-120064.001 Universal Link Housing Heard OR 97223 11 3 G450ML Fusible Link-Globe 450°F TOTALS 6 12 1 87-120012-001 F Nozzle - `"- ' ''t °"" Kidde 4 Gal 13 1 87-10000.000 4"Mechanical Gas Valve � .. 712616 I o 00 Wet Chemical Suppression ,ADP ADP i 3/811 ADPQ R < ,>. ADP 1111001.117/2" Gyro F Table 7 \ Open ' .-- Hood one Range Gas GrillRc. R.,cr,nA1.. • Gas `' 1 —us Fryer Sales&Service Inc. 14 n Portland,OR 150248,1948 \ / CC88t116821 \ n99s, Brazing Gyros 13815 SW Pacific Hs Tigard OR 97223 Kidde4 Gal kk 7/26/16 2 NA Kidde XVTM Control System a',;Y. Kidde Fire a Systems • P/N: 87-120099-002 Effective: August 2013 K-87-027 FEATURES • For Use in: • Operates 2 Gas Valves • WHDR TM Commercial Cooking Fire • Available 24 V Electrical Actuation Suppression Systems • Multiple Remote Release Options • IND TM Industrial Fire Suppression Systems • Rugged,Die-Cast Aluminum Body • Pneumatic Release of up to 20 Agent Cylinders • Tamper/Lock Port for Cover • Two Discrete Mechanical Detection Lines • Easy to Install and Maintain • Cylinder or Wall Mount • UL&ULC Listed • Up to 400 ft.Mechanical Detection Cable • FM Approved for IND Systems DESCRIPTION The Kidde XV Control System is a compact, versatile unit discharging the WHDR wet chemical or IND dry chemical used to actuate agent cylinders on Kidde WHDR and IND suppression agent. The XV can be mounted on a wall or Pre-Engineered fire suppression systems. The control directly to an SVA mounted on the cylinder. head can be operated via: The XV Control System is UL and ULC Listed with • Two Distinct Automatic Mechanical Detection Lines WHDR Wet Chemical and IND Dry Chemical Fire (fusible links or thermo-bulb links) Suppression Systems. The XV is FM approved with the • Optional Electrical Solenoid IND Dry Chemical Systems. • Remote or Local Manual Mechanical Control The XV comes ready to install, with three EMT . Upon actuation, the XV Control System discharges the connectors, one System Valve Actuator (SVA), two nitrogen System Cartridge, pressurizing the actuation microswitches, one nitrogen System Cartridge, and one lines and System Valve Actuators (SVA) mounted on the nitrogen test cartridge. cylinder valve(s). The SVA(s) open the cylinder valve(s), zKidde Fire Systems, y, f SUPPNESSEON SYSTEM Figure 1. XV Control System, P/N 87-120099-002 TECHNICAL DATA Table 1. Mechanical Cable Parameters for WHDR & IND Systems XV Cable Line Max. Cable Max. Corner Max. Max. Tee Length Pulleys Detectors Pulleys Detection and Manual Release-to-Trip Line 1 200 ft. (60.96 m) 50 40 Detection and Manual Release-to-Trip Line 2 200 ft. (60.96 m) 50 40 Pull-to-Trip Remote Manual Release Line 100 ft. (30.48 m) 30 - 1* Mechanical Gas Valve Line 100 ft. (30.48 m) 30 - 1* *Tee pulleys count as two Corner Pulleys. Maximum is from XV Control, through the pulley,to each device. Table 2. Actuation Parameters for WHDR Wet Chemical Systems Operating Number of Maximum Total Length Minimum Total Length of Copper Temperature Extinguishing Copper Actuation Tubing Actuation Tubing Range System Cylinders 0°F to 120°F 1-12 106 ft. (32.30 m) (-18°C to 49°C) 13-20 91 ft. (27.73 m) 5 ft. (1.52 m) Table 3. Actuation Parameters for IND Industrial Dry Chemical and Open-Face Spray Booth Systems 11, Operating Number of Maximum Total Length Minimum Total Length of Copper Temperature Extinguishing Range System Cylinders Copper Actuation Tubing Actuation Tubing -40°F to 120°F 1-14 166 ft. (50.60 m) (-40°C to 49°C) 15-20 121 ft. (36.88 m) 5 ft. (1.52 m) Table 4. Actuation Parameters for IND Dry Chemical for Vehicle Spray Booths Operating Number of Maximum Total Length Minimum Total Length of Copper Temperature Extinguishing Copper Actuation Tubing Actuation Tubing Range System Cylinders 1-8 200 ft. (60.96 m) 0°F to 120°F (-18°C to 49°C) 9-15 160 ft. (48.76 m) 5 ft. (1.52 m) 16-20 140 ft. (42.67 m) NOTES 1. Braided high pressure nitrogen tubing (P/N 87-120045-00X), is required to connect the XV Control System to the System Valve Actuator(SVA)when the XV Control System is cylinder mounted. 2. Copper tubing shall be 1/4-inch O.D. x 0.031-inch wall high pressure tubing. 3. When Control System is cylinder mounted and two or more cylinders are being actuated, a minimum of 5 ft. (1.52 m) of 1/4-inch O.D. x 0.031-inch wall tubing shall be used for actuation lines. • -2- 4. Wbe hen Controlusedthe Systemoverall isactuation wall mountedl , a minimum of 5 ft. (1.52 m)of 1/4-inch O.D. x 0.031-inch wall tubing shall in 5. High pressure nitrogen tubing (P/N 87-120045-00X) may be used in place of copper tubing, not to exceed a max- imum length of 30 feet(9 m). 6. In every system, either single cylinder or multiple cylinder, a 1/8-inch NPT plug or vent check (P/N WK-877810- 000) shall be used in the outlet port of the last System Valve Actuator(s) in the actuation line. 7. A maximum of 2 Pressure Switches(P/N 486536) may be used in the actuation line. SYSTEM NITROGEN CARTRIDGE, P/N 87-120043-001 The XV Control System uses a nitrogen cartridge for actuating the system cylinders and is charged with dry nitrogen (see Figure 2). The cartridge is mounted inside the XV Control System to protect it from tampering and provides the date of manufacturing and space(gray band)for recording the installation date. 5-1/8 in. (130 mm) *tis S �s w » ,: 4 1-9/16, 6 n. i �"p( p (40 mm) 4 2 )r Ill �h/. 3 GRAY BAND Figure 2. System Nitrogen Cartridge, P/N 87-120043-001 IIITEST CARTRIDGE, P/N 87-120044-001 The Test Cartridge is used for functional testing of the Kidde WHDR Wet Chemical System and IND Dry Chemical System*. The cartridge has a red band and is labeled "TEST CARTRIDGE"as shown in Figure 3. *Note: The System Nitrogen Cartridge P/N 87-120043-001 is required for actuation and full discharge or"puff'tests, and when a time delay is included (as in systems protecting.Vehicle Spray Booths). 4 in. i- (102 mm) 0 I --"'' 1 in. TEST (25 mm) CARTRIDGE la,�d(+; Figure 3. Test Cartridge, P/N 87-120044-001 • -3- 110 SYSTEM VALVE ACTUATOR(SVA), P/N 87-120042-001 A System Valve Actuator(SVA) must be mounted to every system cylinder valve assembly (see Figure 4). The SVA has ports for low profile tubing runs, and is also equipped with a spring loaded plunger that locks the piston in the discharged position, ensuring complete discharge of the cylinder(s) contents. 5/16-18 UNC /'—THROUGH HOLE(TYP) (NOT SHOWN) WS) A � ( NPT 11 'k� P F `\•sl �yi L 1-3/4 in I-{� � k � (44 mm) i 1/8 in.NPT PLUG �� � (IF APPLICABLE) SVA PISTON IN SPRING LOADED SET POSITION PISTON IN ACTUATED PLUNGER POSITION(TOWARDS CYLINDER VALVE) Figure 4. System Valve Actuator(SVA), P/N 87-120042-001 HIGH-PRESSURE NITROGEN TUBING, P/N 87-120045-0OX The High-Pressure Nitrogen Tubing is used to connect the XV Control System to the SVA on all installations in which the XV Control System is mounted to a wet or dry chemical cylinder. (see Figure 5).A 1/8-inch NPT(male)x 3/8-24 JIC Adapter is included with the High Pressure Nitrogen Tubing. • 1/8 in.NPT 1/2 in.HEX, SEAT 1/4 in.37 DEGREE THREAD FLARE,SWIVEL ANNOO JOIN1/8 in.NPT A (END TO SEAT) (MALE)x 3/8-24 JIC ADAPTER Figure 5. External Tubing for XV Control System, P/N 87-120045-OOX Table 5. External Tubing for XV Control System Part Number Length "A" 87-120045-001 7-1/2 in. (191 mm) 87-120045-002 24 in. (610 mm) 87-120045-003 60 in. (1524 mm) • -4- 1111 SOLENOID, P/N 83-100034-001 WIRE TYPE KEY ALARM WIRES TO XV —'—'—'—.—'—' SOLENOID AND/OR OTHER An optional solenoid can be installed into the XV Control DEVICES MICROSWITCH(INTERNAL) System, just under the actuation latch. The solenoid operates directly on the actuation latch to activate the ALARM WIRES FROM CONTROL PANEL system. This installation allows simultaneous usage of mechanical detection lines, or the lines can be lockedPIN 83-100034-001 OPEN TERMINAL T4 VOC ONLY FLAG ENGAGED TERMINAL 2NOT USED out. The solenoid includes two mounting bolts, the bracket and a push plate which mounts onto the solenoid \ l BY XV body (Figure 6). The solenoid coil is 24 Vdc at 1.5 Amp \ • l ' and at 70°F(21°C). Refer to Figure 7 for Release Wiring with Terminal Type Microswitch. I! iiATTACH SOLENOID LEAD TO When actuating the XV Control System with an optional _ , _ TERMINAL 1 OF MICROSWITCH RELEASING CIRCUIT COMMON solenoid, a UL Compatible and Listed fire control panel INCOMPATIBLECONTROL TERMINAL1 PANEL(24 VDC ONLY) ATTACH RELEASING CIRCUIT TO with a supervised power supply is required, such as the TERMINAL 40F MICROSWITCH Kidde AEGIS or Kidde ARIES. SPLICE SOLENOID LEAD CLOSED TERMINAL TO RELEASING CIRCUIT PUSH PLATE _.,.P+ sms .. 9/64 in.ALLEN SCREWS(2) SWITCH POSITION WHEN XV FLAG/CAM IS IN SET POSITION (DO NOT REMOVE) 'h`s""P - a" MOUNTING BRACKET Figure 7. Release Wiring with Terminal Type Microswitch ' l-(DO NOT REMOVE) Note: Where electric detection and/or actuation is pro- vided, supervision shall be provided in accor- ELECTRICAL LEADS /�24 in.(610 mm) dance with NFPA 72, National Fire Alarm and , �d Signaling Code. Alarms and indicators, along – -= with a supervised power source, shall be pro- SOL ENOID BODY ,, vided in accordance with NFPA 72. Electrical wir- ing and equipment shall be provided in accordance with NFPA 70, National Electric Code.All installations are subject to the approval of the Authority Having Jurisdiction (AHJ). Figure 6. Solenoid, P/N 83-100034-001 KEEPER PIN, P/N 60-9197108-000 The Keeper Pin (P/N 60-9197108-000) is used to prevent actuation while installing the system. / i Figure 8. Keeper Pin, P/N 60-9197108-000 Ask 11, -5- 0 ORDERING INFORMATION Description Part Number XV Control System includes: (1) 87-120042-001 System Valve Actuator (1) 87-120043-001 System Nitrogen Cartridge (1) 87-120044-001 Test Cartridge 87-120099-002 (1) 87-120058-001 EMT Connector Kit (1) 87-120039-001 Microswitch Kit (1) 87-120039-501 Microswitch Kit System Valve Actuator 87-120042-001 System Nitrogen Cartridge 87-120043-001 Test Cartridge 87-120044-001 High Pressure Hose for Cylinder Mount 87-120045-001 EMT Connector Kit 87-120058-001 Solenoid Electric Actuator Kit 83-100034-001 Microswitch Kit(SPDT), Solid Color Leads 87-120039-001 Microswitch Kit(SPDT), Striped Color Leads 87-120039-501 Terminal Type Microswitch Kit(SPDT) 87-120047-001 REFERENCE INFORMATION is • WHDR Systems designed and installed according to • Vehicle Spray Booth Systems designed and installed manual P/N 87-122000-001. according to manual P/N 83-100036-001. • IND Systems designed and installed according to manual P/N 220423. MOUNTING MOUNTING HOLE �— 140 mm)—n. i HOLE ( 1'.'•', .-- 2 41).) ,t A \: .0-Kidde , '- F'Irc Systems 0o 110,, ,\ w.E r '` -}-- r -:-3--- 7-5/13in. + y ,; . fit tri 9314„ m 2 °t ti (248 mm) (194 ) 1 {I� /"^Y.'' JURN HANDLE, \'' -'� i N \ S '+ as ,, /-"� i � FIRE SUPPRESSION SYSTEM {VA r ., 3/4in. .' I 't# (19 mm) _..T,71"'`Z-., s°,, aeai .ePIP 4 8-1/2" � 3-3/4" MOUNTING 14---,...4____4-3/0/n. '' (95 mm) (216 mm) HOLE (112 mm) MOUNTING 1-5/16 in. HOLE (34 mm) Figure 9.XV Control System Dimensions Kidde is a registered trademark of Kidde-Fenwal,Inc. WHDR,IND,XV,AEGIS,and ARIES are trademarks of Kidde-Fenwal, • This literature is provided for informational purposes only. KIDDE-FENWAL,INC. 4 • assumes no responsibility for the product's suitability for a particular application.The ' Kidde Fire e System s product must be properly applied to work correctly. . If you need more information on this product,or if you have a particular question,contact KIDDE-FENWAL,INC.,Ashland,MA 01721.Telephone:(508)881-2000. 400 Main Street Ashland,MA 01721 Tel.:508-881-2000 K-87-027 Rev AG ©2013 Kidde-Fenwal Inc. Fax:508-881-8920 www.kiddefiresystems.com 0 y A s TOP OF CENTER OF CYLINDER VALVE ;.,z DISCHARGE PORT r IA =-.I NOMINAL CYLINDER DIAMETER Figure 2-1. Dimensions of Cylinder and Valve Assembly, P/N 87-12XXXX-001 Refer to Figure 5-26 for Cylinder Valve details. STable 2-1. Cylinder and Valve Assembly Specifications Cylinder and Valve Dimensions Assembly Part Model Maximum Flow ow Number A B C 87-120001-001 WHDR-125 4 15-1/4 in. 13-3/4 in. 8 in. (387 mm) (349 mm) (203 mm) 87-120002-001 WHDR-260 8 21 in. 19-5/S in. 9 in. (534 mm) (498 mm) (230 mm) 87-120003-001 WHDR-400S 12 19 in. 17-1/2 in. 12-1/4 in. (483 mm) (444 mm) (311 mm) 87-120006-001 WHDR-400M 12 24-3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) 87-120005-001 WHDR-600 18 35-1/8 in. 33-3/4 in. 10 in. (892 mm) (857 mm) (254 mm) 87-125001-001 WHDR-5EU 4 15-1/4 in. 13-7/8 in. 8 in. (381 mm) (352 mm) (203 mm) 87-125002-001 WHDR-10EU 8 21 in. 19-5/8 in. 9 in. (533 mm) (498 mm) (229 mm) 87-125003-001 WHDR-S15EU 12 18-7/8 in. 17-1/2 in. 12 in. (479 mm) (445 mm) (305 mm) 87-125006-001 WHDR-M15EU 12 24-3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) 87-125005-001 WHDR-23EU 18 35 in. 33-1/2 in. 10 in. (889 mm) (851 mm) (254 mm) • i CYLINDER STRAP C. A x' Figure 2-3. Shelf Bracket, P/N 87-100013-001 Table 2-3. Mounting Bracket Dimensions Dimensions Part No- Model A B C 87-100013-001 WHDR-600,WHDR-400M, 11 in. 10-1/8 in. 21-1/8 in. WHDR-M15EU, WHDR-23EU (279 mm) (258 mm) (537 mm) S • • Component Description 2-3.11 1/2-inch Vent Plug, P/N 60-9196984-000 A 1/2-inch Vent Plug is used in the discharge piping near a Kidde cylinder to prevent pressure build-up in the discharge pipe system, caused by heat, from rupturing the foil seals on each nozzle. The 1/2-inch Vent Plug is to be installed in the discharge piping so that it faces the ceiling or the wall. CAAoN NEVER INSTALL IT FACING DOWN OR AT THE FLOOR. UTI 112 in. 113 mm) NPT *ate".«'""' 1.1/8 in. (25 mm) Figure 2-50. 1/2-inch Vent Plug, P/N 60-9196984-000 4 0 DISCHARGE ADAPTER KIT, P/N 83-844908-000 The Discharge Adapter provides a means to connect agent distribution pipe to all Kidde Wet Chemical Cylinder and Valve Assemblies. The Discharge Adapter Kit consists of a 3/4-inch NPT external thread and 1/2-inch NPT internal thread adapter and a steel flange plate (Figure 2-5). Note: The nuts and bolts used to secure the Anti-Recoil Plate to the discharge valve should be retained and used for mounting the Discharge Adapter to the valve outlet. The Discharge Adapter can also be used as a recharge adapter to pressurize the cylinder with nitrogen after filling with wet chemical. Note: This part must be ordered separately. It is not included with the Cylinder and Valve Assembly. FLANGE PLATE III 912 in.NPT s , � ' ,'4-'m 44 (INTERIOR) rL gl� h r 0 ADAPTER 314 in.NPT " z R, a- , (EXTERIOR) `" 0-RING Figure 2-5. Discharge Adapter Kit, P/N 83-844908-000 • • Component Description 2-2.4 Remote Manual Releases 2-2.4.1 REMOTE MANUAL RELEASE, P/N 875572 (XV ONLY) The Remote Manual Release, shown in Figure 2-35, is provided as a means of manually actuating the system from a remote location. The Remote Manual Release is attached to the XV Control System with 1/16-inch control cable.To actuate the system at the Remote Manual Release, pull out the safety pin and pull hard on the handle. Each Remote Manual Release is supplied with a separate nameplate.This nameplate must be attached to the mounting surface 1-inch above or below the Remote Manual Release. ... s 3-5/8 in. � g w (92.2 mm)410 ;" ' { '�, l 1 ti . 1-1/2 in. - 438 mm) Figure 2-35. Remote Manual Release, P/N 875572 P/N 87-122000-001 2-31 April 2009 Kidde WHDRTM Agent400 . Discharge Nozzles• I' Kidde Fire Systems A UTC Fire&Security Company Effective: June 2010 P/N 87-1200)0C-001 ----,, K-87-011 FEATURES ... ".°" • For Use in WHDRT'"Commercial Cooking • Grooved Rings for Easy Identification Fire Suppression Systems • Foil Seal Prevents Clogging from Grease • Stainless Steel Internal Strainer • Available Swivel Adapter for Easy Aim Adjustment • Nickel-Chrome Plated Brass Body DESCRIPTION There are seven agent discharge nozzles available for use with the Kidde WHDR Wet Chemical Suppression System. Each nozzle has a specific flow number which is an indication of the discharge rate. Nozzle types are selected based 0 upon the specific hazard being protected.All nozzles have a 3/8-in. NPT female thread and are stamped with the noz- zle type(see Figure 1). INTERNAL THREAD 3/8 in.NPT -\4 ilot 7 7/8. o` 4 ----.....,v 41, { r leV 13/16 in.(21 mm) 1 GROOVE 9/16 in.(14 mm) Figure 1. ADP Nozzle A swivel adapter(P/N 87-120021-001) may be used with each nozzle to facilitate proper aim (see Figure 2). F2-1/106 in.(52 mm) 3/8 in.(10 mm)NPT �`• _�� 3/8 in.(10 mm)NPT ,trit. . �- (INTERNAL THREAD) 1 in.(25 mm)HEX J \-- 7/8 in.(22 mm)HEX Figure 2. Nozzle Swivel Adapter 0 * TECHNICAL DATA Table 1: Nozzle Application Information Nozzle Reference in WHDR Wet Type Part Number Flow Chemical DIOM Manual Application (P/N 87-122000-001) Split Vat Deep Fat Fryer(Low Proximity) Paragraph 3-4.6 Max. Hazard Area: 14 in.x 15 in. (356 mm x 381 mm) Max.Appliance Area: 14 in.x 21 in. (356 mm x 533 mm) Krispy Kreme Model 270 d/h Doughnut Fryer 8 ADP Nozzles Required,8 Total Flows, Dedicated Paragraph 3-4.8 WHDR-600 Cylinder Max. Depth (front-to-back): 33 in. (840 mm) Max. Length(left-to-right): 93 in. (2362 mm) Upright Broiler Paragraph 3-4.13 Max. Internal Broiler Compartment: 30-1/4 in.x 34 in. (768 mm x 864 mm) Natural or Mesquite Charcoal Charbroiler Paragraph 3-4.16 Max.Cooking Surface:24 in.x 24 in.(610 mm x 610 mm) 87-120012-001 Max Fuel Depth: 6 in. (152 mm) Chain Broiler(Closed-Top) ADP ilia- i 1 Paragraph 3-4.18 Max. Internal Hazard Area:28 in x 29 in. (711 mm x 737 mm) 1 Groove Chain Broiler(Open-Top) Paragraph 3-4.19 Max. Internal Hazard Area.:28 in x 29 in. (711 mm x 737 mm) Griddle-Flat Cooking Surface With or Without Paragraph 3-4.20 Raised Ribs Max. Hazard Area:30 in.x 42 in. (762 mm x 1067 mm) Plenum No Filter: 10 ft.x 4 ft. (3 m x 1.2 m)Max. Paragraph 3-6.1 "V" Filter: 10 ft.x 4 ft. (3 m x 1.2 m)Max. Per Nozzle Single Bank Filter: 10 ft.x 4 ft. (3 m x 1.2 m)Max. Per Nozzle Duct Paragraph 3-6.1.1.1 Up to 50 in. (1270 mm)perimeter per nozzle Max.Throw: 11.78 in. (300 mm) Unlimited duct length 87-120013-001 Gas Radiant/Electric Charbroiler Paragraph 3-4.15 Max. Cooking Surface: 21 in.x 24 in. (533 mm x 610 ., mm) GRW �� 010101 1 Wok Paragraph 3-4.21 Diameter: 14 in.to 28 in. (356 mm to 711 mm) 3 Grooves Depth: 3 in.to 8 in. (76 mm to 203 mm) • -2- • Table 1: Nozzle Application Information (Continued) Nozzle Reference in WHDR Wet Type Part Number Flow Chemical DIOM Manual Application (P/N 87-122000-001) Single Vat Deep Fryer Paragraph 3-4.1 Max. Hazard Area: 18 in.x 18 in. (457 mm x 457 mm) Max.Appliance Area: 18 in.x 23 in. (457 mm x 584 mm) 18-1/2 in.x 24-1/2 in.(470 mm x 622 mm)Deep Fat Fryer Paragraph 3-4.2 (2) F Nozzles Required,4 Total Flows Max.Hazard Area: 18-1/2 in.x 18 in.(470 mm x 457 mm) Max.Appliance Area: 18-1/2 in.x 24-1/2 in. (470 mm x 622 mm) Split Vat Deep Fat Fryer 87-120012-001 Paragraph 3-4.3 Max. Hazard Area: 14 in.x 15 in. (356 mm x 381 mm) Max.Appliance Area: 14 in.x 21 in.(356 mm x 533 mm) F 2 14 in.x 14 in.(356 mm x 356 mm)Deep Fat Fryer Paragraph 3-4.4 Max. Hazard Area: 14 in.x 14 in. (356 mm x 356 mm) Max.Appliance Area: 14 in.x 24-1/2 in. (356 mm x 622 2 Grooves mm) Single Vat Deep Fryer with Drip Board less than 1 in. Paragraph 3-4.5 (25 mm) • Max. Hazard Area:24 in.x 24 in. (610 mm x 610 mm) Max.Appliance Area:24 in.x 25 in. (610 mm x 635 mm) Charbroiler(Lava,Pumice,Ceramic,or Synthetic Paragraph 3-4.14 Rock) Max.Appliance Area:22 in.x 23 in. (559 mm x 584 mm) Paragraph 3-4.22 Tilt Skillet(Braising Pan) Max. Hazard Area:24 in.x 24 in. (610 mm x 610 mm) Four-Burner Range 87-120014-001 Paragraph 3-4.9 Max. Hazard Area: 28 in.x 28 in. (711 mm x 711 mm) Shape of Burner Not Important R 11 ,, 1 Two-Burner Range Paragraph 3-4.10 Max. Hazard Length:28 in. (711 mm) Shape of Burner Not Important 4 Grooves Paragraph 3-4.11 Single-Burner Range Shape of Burner Not Important 87-120015-001 Mesquite Log Charbroiler DM 3 Paragraph 3-4.17 Max Cooking Surface:30 in.x 24 in. (762 mm x 610 mm) Max. Fuel Depth: 10 in.(254 mm) May Use Wood Chips, Chunks, Logs or any Combination 0 Grooves • -3- ..-.. .-. _- Table 1: Nozzle Application Information (Continued) • Nozzle Reference in WHDR Wet • Part Number Flow Chemical DIOM Manual Application Type (P/N 87-122000-001) 87-120022-001 Deep Fat Fryer(Low Proximity) LPF ®®PMax. Hazard Area: 14 in.x 15-1/2 in. (356 mm x 394 mm) 2 Paragraph 3 4.7 Max Appliance Area: 14 in.x 23-1/4 in. (356 mm x 591 mm) 1 &4 Grooves 87-120024-001 a s LPR ISal I 1 Paragraph 3-4.12 Four-Burner Range(Low Proximity) Max. Hazard Area:24 in.x 24 in. (610 mm x 610 mm) Disc&Core ORDERING INFORMATION Description Part Number ADP Nozzle 87-120016-001 (10-pack of 87-120011-001) • F Nozzle 87-120017-001 (10-pack of 87-120012-001) GRW Nozzle 87-120018-001 (10-pack of 87-120013-001) R Nozzle .87-120019-001 (10-pack of 87-120014-001) DM Nozzle 87-120020-001 (10-pack of 87-120015-001) LPF Nozzle 87-120023-001 (10-pack of 87-120022-001) LPR Nozzle 87-120025-001 (10-pack of 87-120024-001) Swivel Adapter 87-120021-001 (each) Foil Seals 60-9197054-000(10-pack) Disc Cap 60-9197290-001 (10-pack, not for LPR nozzle) Disc Cap,LPR 87-120026-001 (each,for LPR nozzle only) Kidde is a registered trademark of Kidde-Fenwal,Inc. WHDR is a trademark of Kidde-Fenwal,Inc. • This literature is provided for informational purposes only. KIDDE-FENWAL,INC. j Kidde Fire Systems assumes no responsibility for the product's suitability fora particular application.The product must be properly applied to work correctly. If you need more information on this product,or if you have a particular question,contact A UTC Fire&Security Company KIDDE-FENWAL,INC.,Ashland,MA 01721. 400 Main Street Ashland,MA 01721 Ph:508.881.2000 K-87-011 Rev AE ©2010 Kidde-Fenwal Inc. Printed in USA Fax:508.881.8920 www.kiddefiresystems.com • System Design 3-6 VENTILATION 3-6.1 Plenums Table 3-29. Plenum Protection Items Parameters ADP Nozzle No Filter 1 10 ft.x 4 ft.( 3 m x(2 m)Max, 1-located at one end of the plenum Filter 10 ft.x4 ft.(3 m x 12 in) 1-located at one end of the plenum 20 ft.x 4 ft.(6 m x(2 in) 2-located at end of plenum pointing inwards Single Bank Filter 10 ft.x4 ft.(3 m x 1.2 in) 1-located at one end of the plenum 20 ft.x 4 ft.(6 m x 1.2 m) 2-located at end of plenum pointing inwards When no filters are present,the nozzle protecting the plenum is used to,discharge the wet chem- ical on the underside of the hood.In this case,the hood.may not exceed a length,of 10 ft. (3 in) or a width 014 ft. (1.2 m). Plenums larger than 10 ft. (3.0 m)x 4 ft.(1.2 m)may be protected by adding additional ADP nozzles for each additional 10 ft. (3.0 m)of plenum length and each additional 4ft.(1.2 m)of plenum width.Nozzles may be installed pointing in the same direction,and/or at the ends of the plenum pointing toward each other(see Figure 3-28). Each nozzle will provide coverage for a maximum of 10 ft. (3 m)of plenum length and 4 ft.(1.2 m)of plenum width. ADP nozzles must be centrally located in the plenum with their discharge directed along the length of the plenum and located in relation to the filters as shown in Figure 3-28. Refer to Figure 3-28 for filter height. • • • System Design 4 St AoisL1.2snii. DUC;r100.000000,711110.1"-.... 14 St aticr 141411111.' • —.'1111111111°I 4 c 4., poi. ..,..„,.. i . .azz-LE .0000," 4ft. , ir„,,,-716m1 / fl..2.4.0:yr LVeiVIVA ig "V"FILTER BANK COVERAGE 'V'FLIER BANE COVERAGE 10 tt.(3 m)PLENUM 20 ft.(6m)PLENUM `. 1,40771 V ... 3,414 1..k,...e'riAili I AIM "V"FILTER BANK COVERAGE(EfLi VIEW) .,..4r, 41L 1110 Aoloii.-14o) Ewer . 14,0. 101•00,••jor. I, , {14;:t) NCGM12-1 ., . . . 4 ,... . '' .......---- ,..."4, V 4 tt 4 S1.2 asi>/le 141027-1-E SINGLE ALTER BANK COVERAGE SINGLE FILTER BANK COVERAGE 10 ft(3 in)PLENUM 20 ft.(6 na)PLENUM -0-Iv3044- -4- • ft '46, 1- 14"w-el SINGLE BANK FILTER COVERAGE(ENO VIEW) Figure 3-28, ADP Protection Nozzle,P/N 87-120011-001 Apr it 2009 3-34 PIN V-122000-00/ • System Design 3-6.1.1.2 Ducts 50 to 100 inches in Perimeter • Two ADP nozzles, P/N 87-120011-001, pointing in the same direction are required for protection of ducts with perimeters greater than 50 inches and less than or equal to 100 inches. Ducts can be of unlimited length (refer to Figure 3-30). For other option of ducts up to 75 perimeter inches (See Figure 3-32). Note: All Kidde systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT HOOD 14 X X � '/?X ( , yo( '/d '/d MAX.DIAMETER 31.83 in.(809 mm) E--� 4X • NOZZLES TO BE ALONG ONE 25 . mm) CENTERLINE AT THE 1/4 POINTS. MAX.MXSIDE • NOZZLES TO BE 0-6 in.(0-152 mm) UP FROM ENTRANCE OF VERTICAL DUCT MAX.DIAGONAL 11.78 in.(300 mm) • MAX.DIAGONAL TY P•(2)ADP NOZZLES 11.78 in.(300 mm) SQUARE RECTANGULAR ROUND ADP NOZZLE 0 to 6 in. (O to 152 mm) 4 DUCT ENTRANCE l— it is OF VERTICAL DUCT LL OF HORIZONTAL DUCT .4i i 2-4 in.(51 mm-102 mm) A ADP NOZZLE )1i/ ` AIM POINT NOZZLE TIP TO DUCT HIP VERTICAL/HORIZONTAL DUCT Figure 3-30. Duct Protection Using Two ADP Nozzles, P/N 87-120011-001 • April 2009 3-36 P/N 87-122000-001 0 System Design 3-4.4 14 in.x 14 M.(356 mm x 356 mm) Deep Fat Fryer Table 3-5.F Nozzle Coverage Area Items Parameters Maximum Hazard Area: 14 in.x 14 in. (356 mm x 356 mm) Maximum Appliance Area(with drip board) 14 in.x 24-1,12 in.(356 mm x 622 mm) Nozzle Aim Midpoint of hazard area Nozzle Location(from bap of appliance at an angle of 450 or 27-112 in. (686 mm)MM. more from the horizontal) 45 in.(1143 mm)Max. AN F INDEELE WAX SE LOCKED ANYWHERE worm THE ME ,VIN F NOZZLE AlW SE I LOCATED ANYWHERE WORRY THE GRID 46 5n 41143 awn) DAGONAL FROW MAX ANA POINT o ka- ieleritifilihNINis 4, 014-1,.FAA 4am..rtuatn,..,1 MAX "11111111111111// NCE2LE LOCATCAN 4,5"OR WORE FROZ ''s / • . ,, Irv: Z7412'.- teeliatAVAA: ,,"--HAZ443DMIPC"TACcL HON AA AN SAN Val rel. /71( \ NAZAR614°PCINTMAIOP°AREA7F vozoals‘ 0 sweA/ 14 fa.4166 rum) wAx ZA,112 W. 1402 HAW WAX .1 \ ORIP BOARD A MARCHED 4 I. 14 An.gm Angrt)MAX. I 24.1.7 lin-eiz2 Alm)WAX AFPL1ANCE AREA w 14 in.pos Num)WAX--• FRotir'view SIDEPIEW Figure 3-5. 14 in.x 14 in. (356 mm x 356 mm) Deep Fat Fryer • • System Design 3-4.20 Griddle— Flat Cooking Surface(With or without Raised Ribs) Table 3-26.ADP Nozzle Coverage Area items Parameters Maximum Hazard Area 30 in.x 42 in.(762 mm x 1067 mm) Nozzle Aim At a paint 3 in.(76 mm)from the midpoint of hazard area • Nozzle Location—any point on the perimeter of 13 in. (330 mm) appliance 48 in. (1219 mm)Max. Note: Positioning the nozzle directly over the appliance is not permitted. 44/ 4310. 4 11213 nim) • MAX ‘1‘' / / 30 M.. dk t (?2mm) lir 13I. MAX. Annv) / IOC Y TOP 00APPLIANCM 42 Id. 0047 frans) THEMMPLICIND403414,0Fat jamomen)P.A80USmerCill MAX. Figure 3-22. Griddle- Flat Cooking Surface • 1110 °el System Design 3-4.10 Two Burner Ranges Nozzle Aim LengTithable 3-14. R Nozzle Coverage Area —Two Burner Range Items 28 in. (711 mm) Midpoint of hazard are Para Nozzle Location-Anywhere within the area of a circle 20 in. (508 mm)MM. generated by a 9 in.(229 mm)radius about the midpoint Note:Shape of burner not important. 42 in. (1067 mm)Max. 18 In..(457 mm)DiA. (FROM TOP OF RANGE) I THE SHADED AREA 20 lit(508 mm)INN. I (FROM TC 28 (711 mm)MAX. HAZARD A.REA 42 ln.(1087 min)MAX. LOCATED M. OF RANGE) — 11111111E1149 01111 r 1114PrgiliF 1/1111( Pm eters Maximum Hazard AIM POINM MIDPOINT OF HAZARD AREA 14 kL(356 mm)MAX_BURNER LENGTH CENTERLINE TO CENTERLINE Figure 3-11. R Nozzle Coverage for a 2-Burner Range Kidde Heat Detector Links 4using Kits rKidde Fire Systems A UTC Fire&Security Company Effective: June 2010 K-87-012 FEATURES • For Use in: • Wide Selection of Link Types and • WHDRT""Commercial Cooking Fire Temperature Ratings Suppression Systems • Rapid Response Links Available for • INDT"'Industrial Fire Suppression Systems Increased Spacing on IND Systems • For Use with Alfrm Control System and KRS-50 • Low Cost Reliable Detection Control Box DESCRIPTION Heat Detector Links There are two types of mechanical heat detector links available for use with Kidde WHDR and IND fire suppression systems: • Thermo Bulb links, available in Standard Response(KGS)and Rapid Response (KGR) (Figure 1) • Fusible metal alloy links, Model KML(Figure 2)and Model KFA(Figure 3) RAPID RESPONSE STANDARD RESPONSE THERMO-BULB LINK THERMO-BULB LINK • iplimp all Ole Figure 1. Thermo Bulb, P/N 87-12009X-XXXxsFigure 2. KML Heat Detector Links, P/N WK-282661-XXX,I Ill° Figure 3. KFA Heat Detector Link, P/N 87-120060-001 • Standard Response and Rapid Response Thermo Bulb Detector Links are available in six different temperature ratings (Table 1). KFA Detector Links are available in a 360°F(182°C)temperature rating only(Table 2). Thermo Bulb and KFA Detector Links can be used with the XV Control System or the KRS-50 Control Box. KML Detector Links are available in four different temperature ratings (Table 2) and are listed for use with the XV Con- trol System only. Detector selection is based on the maximum expected exposure temperature determined via heat survey during nor- mal operating conditions (refer to Table 1 and Table 2). Detector load ratings are shown in Table 3. Table 1. Thermo Bulb Detector Link Ratings Rapid Response Detector Standard Response P P Temperature Color Maximum Part Number Part Number Exposure Temperature Rating 87-120090-165 87-120095-165 165°F (74°C) Red 100°F (38°C) 87-120090-212 87-120095-212 212°F (100°C) Green 150°F (65°C) 87-120090-286 87-120095-286 286°F (141°C) Blue 225°F (107°C) 87-120090-360 87-120095-360 360°F (182°C) Mauve 300°F (149°C) 87-120090-450 87-120095-450 450°F (232°C) Black 375°F (191°C) 87-120090-500 87-120095-500 500°F (260°C) Black 435°F (224°C) • Table 2. KML and KFA Detector Link Ratings Fusible Metal Detector Detector Temperature Maximum Exposure Link Part Number Ratin Color 9 Temperature Model KML WK-282661-000 165°F (74°C) Yellow 100°F (38°C) WK-282662-000 212°F (100°C) White 150°F (65°C) WK-282664-000 360°F (182°C) Unpainted 300°F (149°C) WK-282666-000 500°F (260°C) Orange 440°F (226°C) Model KFA 87-120060-001 360°F (182°C) Unpainted 300°F (149°C) Table 3. Detector Link Load Ratings Detector Type ' Minimum Load Maximum Load Thermo Bulb 0 lb. (0 kg) 50 lb. (22.7 kg) ML 10 lb. (4.5 kg) 40 lb. (18.1 kg) A 3 lb. (1.4 kg) 45 lb. (20.4 kg) III -2- • 1/16 in.CABLE TO CONTROL SYSTEM "S"HOOKS CRIMP SLEEVE mml THERMO-BULB LINK ��_112�n'�2g2 :12,'..- LOCKNUT OR FUSIBLE-LINK , * . 16" THERMO-BULB LINK OR FUSIBLE-LINK CRIMP SLEEVE 1/ in.EMT EXAMPLE OF END-OF-LINE / CONNECTOR EXAMPLE OF IN-LINE UNIVERSAL HOUSING `S"HOOK UNIVERSAL HOUSING Figure 5. Universal Detector Link Housing (for use with XV or KRS-50 Control Box) Table 5. Universal Detector Link Housing Kit, P/N 60-120064-001 Description Quantity • 11-1/2-in. (292 mm) Link Housing 1 Crimp Sleeve 2 "S" Hook 2 REFERENCE INFORMATION • WHDR systems designed and installed in accordance with manual P/N 87-122000-001 • IND systems designed and installed in accordance with manual P/N 220423 • Vehicle Spray Booth Systems designed and installed in accordance with manual P/N 83-100036-001 • -4- Wet Chemical v • Kidde Fire Systems . Corner PulleyA UTC Fire&Security Company Effective: May 2007 K-87-019 P/N: 844848 DESCRIPTION The Corner Pulley can be used in both low and high tem- perature environments. The pulley contains steel ball bearings and the body is cast aluminum. A 1/16-inch (2 mm) diameter stainless steel 7x7 strand cable is used for the detection line. It is installed using 1/2-inch (13 mm) EMT. STAINLESS STEEL CABLE 2-1/2 in. Iiuh/aipr I 11E7' Fire Systems ) O 1/2 in. (13 mm)i EXPANSION Al EMT FERRULE 1111111111111 INTERNAL __r111M CORNER PULLEY 1110.11_, BEARING 4— STAINLESS STEEL CABLE This literature is provided for informational purposes only. KIDDE-FENWAL,INC.assumes• Kidde Fire Systems no responsibility for the product's suitability for a particular application. The product must be A UTC Fire&Security Company properly applied to work correctly. 400 Main Street If you need more information on this product,or if you have a particular problem or question, contact KIDDE-FENWAL,INC.,Ashland,MA 01721. Telephone:(508)881-2000. Ashland,MA 01721 Ph:508.881.2000 K-87-019 Rev AB ©2007 Kidde-Fenwal Inc. Printed in USA Fax:508.881.8920 www.kiddefiresystems.corn . . Component Description 2-3.3 Mechanical Gas Valve, P/N 87-100001-XXX A Mechanical Gas Valve is required on systems used to protect gas-fueled appliance(s). Upon system actuation, the control stem closes,stopping the gas flow to the appliance(s). Note: Only Mechanical Gas Valves that are specifically UL listed and identified by part number in this manual may be used with the Kidde system. 1— ICONTROL STEM . Allot' 1 I I NVI I I I I I 11 I 1 It INLET ii „irmuilm,_, :: it . ouThEr \\ I 4.1 1%1 il - , 411 Figure 2-42. Mechanical Gas Valve, P/N S7-100001-XXX Table 2-17. Mechanical Gas Valve Sizes Pipe Size Part Number 3/4 in. (19 mm) 87-100001-001 1 in. (25.4 mm) 87-100001-002 1-1/4 in. (32 mm) 87-100001-003 1-1/2 in. (38 mm) 87-100001-004 2 in. (51 mm) 87-100001-005 2-1/2 in. (64 mm) 87-100001-006 3 in. (76 mm) 87-100001-007 April 2009 2-38 P/N 87-122000-001