Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (38)
PITCH: 26 ARRAY PITCH:26 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories 12968 SW Kostel Ln Front Of House (E)DRIVEWAY K I I OI D ; _'J A/C Unlocked Gated LEGEND 0 (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO Lc ® & WARNING LABELS si 125.1 DC DISCONNECT & WARNING LABELS — _ 12" FSB _ _ �H AC DISCONNECT & WARNING LABELS ® �- aM — DC JUNCTION/COMBINER BOX & LABELS 0 DISTRIBUTION PANEL & LABELS W Lc LOAD CENTER & WARNING LABELS CO O DEDICATED PV SYSTEM METER —____ 0RAPID SHUTDOWN II STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR I CONDUIT RUN ON INTERIOR GATE/FENCE A 0 HEAT PRODUCING VENTS ARE RED it ;i INTERIOR EQUIPMENT IS DASHED L_J SITE PLAN N TOTAL ARRAY AREA (SF): 580 TOTAL ROOF AREA (SF): 2258 Scale: 3/32" = 1' W m E TOTAL ARRAY AREA IS a 25.69 01' 10' 21' PERCENT OF TOTAL ROOF AREA "- " s CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9723387 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MIKE COOPER Mike Cooper RESIDENCE Michael Hart N►�`�„ • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: _� ,SOIar�'1 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 12968 SW KOSTEL LN �•.�r y PART TO OTHERS OUTSIDE THE RECIPIENTS 8.32 KW PV ARRAY r�� ORGANIZATION, EXCEPT IN CONNECTION NWTH MODULES TIGARD, OR 97224. THE SALE AND USE OF THE RESPECTIVE (32) REC # REC260PEZ 3055 teo, CAw Way 440 SOLARCITY EQUIPMENT, WITHOUT NE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE San Mateo, 94402 PERMISSION OF SOLARCITY INC. T:(650)638-1028 F:(650)638-1029 ABB # PVI-3.6-OUTD-S-US-Z-A SITE PLAN PV 2 8/22/2016 (888)-SOL-CITY(765-2489)www.sdorcitycom (E) 2x4 PRE—MANUFACTURED TRUSS STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS ® OF THE OSSC SECTION 3111 fi--------.0" --3 \I /B , 7-9" / 5-7' '-4" 5-6" (E) LBW O SIDE VIEW OF MP1 NTS. MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" TOP CHORD 2x4 @ 24"OC ROOF AZI 180 PITCH 26 STORIES:2 ARRAY AZI 180 PITCH 26 BOT CHORD 2x4 @24"OC Comp Shingle PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) — HOLE. 4 SEAL PILOT HOLE WITH ZEP COMP MOUNT C —AsTO )I POLYURETHANE SEALANT. J ZEP FLASHING C `� is �_ (3) INSERT FLASHING. J (E) COMP. SHINGLE !fit ----- (4) PLACE MOUNT. (E) ROOF DECKING V AikVil — INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES —) INSTALL LEVELING FOOT WITH WITH SEALING WASHER (2-1/2" EMBED, MIN) BOLT & WASHERS. (E) RAFTER STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9723387 0 0 PREMISE OWNER: DESCRIPTION: SIGN: CONTAINED SHALL NOT BE USED THE MIKE COOPER Mike Cooper RESIDENCE Michael Hart �a�`,, NOR BENEFIT OF ANYONE EXCEPT SOLARCITYDFORT INC., MOUNTING SYSTEM: SoIarCit''PARTS TO OTHERS OUTSIDDETHE RD IN ECIPIEN E OR INComp Mount Type C 12968 SW KOSTEL LN 8.32 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TICARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (32) REC # REC260PEZ 3055 CleaMew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REN. DALE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A T:(650)636-1028 )638-1029 STRUCTURAL VIEWS PV 3 8/22/2016 (668)-S«-GITY(765-2F4.696)5°,rv„r.solarclty.con, UPLIFT CALCULATIONS #. 08.22.2016 ----'' ' '' YsSolarCity PV aStructural Version#61.7 Design Sof are Mout ntfirl nne Information RoofingMaterialCampf Roof Slope 26° Rafter 53ng 24'"0.C. Framing Type/Direction Y-Y Rafters PV System Type SolarCity SleetkMt tt's -- Zen System Type ZS Comp Stanl,Ahment Hardware) :' Camp Mount Type C' Spanning Vents No Wind and aridSnowlirasion Criteria____ -,---- Wind Design Code ASCE 7-10 " Wind Design Method _ Pa itially/Fully Enclosed Method Ultimate Wind Speed V-Ult 95 mph ' Fig.1609A EinOSure Category C ' ':Section 26.7 Ground Snow Load pg 25.0 psf ASCE Table 7-1 Surrounding Roof Snow 25.0 psi ', ASCE Eq:44-1- Roof Snow Over PV Modules 25.0 psf ASCE Eq:7.4-1 Wind Pressure Priaiiirof-Alculation Coefficients ` " " Wind Pressure Exposure 1(z 0 95 - Table 30.3-1 Topographic Factor KKzt on 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh=0.00256(1(z)(Kzt)(Kd)(V^2) 18.6 psf Equation 30.3-1 Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fe.30.4-2A/eic-sA/8 Exi-Pte$5ure, t oeffident tD T `r '(town) ., X3.45 r.4-�c-We Design Wind Pressure p p=qh(GCp) Equation 30.4-1 VindPrecsurep pp11p) _, 4, F Mint Pnessiire Vii: . r)" 16.41 .st AML- `ANDOFF'SPACINGS ; k jA= Max Allowable Standoff Spacing Landscape 72 39" Ali ti +er Landscape :24' NA. Standoff Configuration Landscape Staggered Max Standofftary.Ar Trib :20.sf PV Assembly Dead Load W-PV 3.0 psf ht Wind'tl Standoff T-al t . , , 3;59"l Uplift Capacity of Standoff Tallow 637 lbs Standoff i mandl/�t OCR ` 24.9% 1t- „3 Imo . Max Allowable Standoff Spacing Portrait 48". 66" Max All+ i e-t ntilev Portrait. - ;N '" Standoff Configuration Portrait Staggered naxstaAdattT " -Area -. ..T . a 22.4 - PV Assembly Dead Load IN-PV 3.0 psf lie Watt Uplift at ado ' 'i.- '-1 ±s Uplift Capacity of Standoff Tallow 637 lbs idoffem C ty '—-27.9°4_.. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9723387 0 0 PREMISE OWNER: DESCRIP11ON: DESIGN: CONTAINED SHALL NOT E USED FOR THE MIKE COOPER Mike Cooper RESIDENCE Michael Hart NOR SH OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM `IttSOlarCitY NOR SHALL IT BE DISCLOSED IN WHOLE oR IN Comp Mount Type C 12968 SW KOSTEL LN =PART TO OTHERS WTSIDE THE RECIPIENT'S8.32 KW PV ARRAY % ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECT1VE (32) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 3055 leo,CleaCA Way PERMISSION OF SOLARCITY INC. VERTEPAGE NAME SHEET: REN DATE: Sm MaeoCA 94402 INR: ABB # PVI—3.6—OUTD—S—US—Z—A UPLIFT CALCULATIONS PV 4 8/22/2016 T:(650)638-1028 F:(650)638-1029 (888)-SOL-CITY(765-2489)www.sdurcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:BR3040B200 Inv 1: DC Ungrounded OR 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:IN27503671 Inv 2: DC Ungrounded INV 1 -(1)FCBinverter;3Zigbee3600WS240V 96X PV A -(32)REC #Module; PEZ # Underground Service Entrance PV 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled RGC, CGC1 INV 2–(1)ABB#PN-3.6–OUTD–S–US–Z–A LABEL: B FCI Inverter; Zigbee 3600W, 240V, 96% Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E 200A MAIN SERVICE PANEL E) 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING CUTLER-HAMMER BRYANT Inverter 1 IND Disconnect (N) 125A Load Center I 200A/2P Q ABB T DC+ Vstart= 200V •R (E) LOADS A B 20A/2P PVI-3.6-OUTD-S-US-Z-A I Dc- MP 1: 1x8 • /TT`• /1 — - n •. _ /A a 240V i t EGC 11 11 / - N _--71_,...--- 4OA 2P _-__ GNDv. _EGC/ DG 1 2 Vstart = 200V IR 14 ~— I I W E I GEC i© �� DG JG MP 1: 1x8 • • 6 I Z 1 I GND I- EGC -GC J VADJUST MIN. ACTIVATION VOLTAGES! -L — N Inverter 2 IND Vo ––– EGC/GEC – © ABB "i DC+ Vstart = 200V —� — 20A/2P G MP 1: 1x8II T n PVI-3.6—OUTD—S—US—Z—A DGEC rI -n-•i•- I' Li 1240Vj 1 t EGC 3 I TO 120/240V I I I • L2 ._--- Dc+ I SINGLE PHASE I N Z�� DG I 1:,C+ Vstart= 20OV UTILITY SERVICEL_�v` _ Eca ____ Dc+� GEC 1N �� DG- G MP 1: 1x8 I 1 I GND ____EGC_ - GC m I I I Voc* = MAX VOC AT MIN TEMP POI—(1)cnER–HAMMER#BR240 PV BACKFEED BREAKER A —(1))CUTLER–HAMMER DG222URB D t.r Breaker; 40A 2P, 2 Spaces Disconnect; 60A, 240Vac, Non–Fusible, NEMA 3R I –(2)Groyrtd Rod –(1)CUTLER–HAMMER #DG100NB 5/8 x 8, Copper Ground/Neutral Kit; 60-100A, General Duty(DG) B I-(1)BRYANT#BR48025RP Load Center; 125A, 120/240V, NEMA 312 –(2)CURER–HAMM #BR220 Breaker, 20A/22P, 2 Spaces —(1)AWG#8, THWN-2, Black ----(--....\----- _ __.__ _. __ ._._ (1)AWG#I0, THWN-2, Black __ __ _ _ ___ _ __ -C– §–(1)AWG#8, THWN-2, Red (1)AWG#10, THWN-2, Red v (2)AWG#10, PV Wire, 600V, Black Voc* =245.43 VDC Isc =9.01 ADC O�, - O –(1)AWG#10, 3/4'HWN-2, Green EGC Vmp =245.6 VDC Imp=$.5 ADC (1)AWG#B, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 MC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 MC (1 Conduit Kit; 3 4 EMT . . . . . , .-(!)AWG#8,.THWN-2,,Green . . EGC/GEC.-(1)Conduit.Kit;.3/4".EMT. . . . . . . . . . . . . . . . .7(1)AWG#8,_1H.W1-2, Green . . EGC/GEC.-(!)Conduit.Kit;.3/4".EMT. . . . . , . . —(2)AWG#10, PV Wire, 600V, Black Voc* =333.43VDC 'Sc =9.01 ADC (!)AWG#10, THWN-2, Black © –(!)AWG#10, THWN-2, Red O –(1)AWG#10, THH –2, Green EGC Vmp =245.6 VDC Imp=8.5 ADC (!)Conduit Kit; 3/4/4"EMT (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 MC (2)AWG#10, PV Wire, 600V, Black Voc* =333.43VDC Isc =9.01 ADC 7.(1)/!WP#8,.TH.WN-2,.Green . . EGC/GEC.-(1)Conduit.Kit;.3/4".EMT. . . . . . . . . . O (1)AWG#10, THHN/THWN-2, Green EGC Vmp =245.6 VDC Imp=8.5 ADC (1)Conduit Kit; 3/4"EMT ®�(2)AWG#10, PV Wire, 600V, Black Voc* =333.43 VDC Isc =9.01 ADC (1)AWG#10, THHN/THWN-2, Green EGC Vmp =245.6 VDC Imp=8.5 ADC III���(1)Conduit Kit: 3/4"FMT CONFIDENTIAL– THE INFORMATION HEREIN JOB NUMBER: JB-9723387 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MIKE COOPER Mike Cooper RESIDENCE Michael Hart �`,r COlar,�l} BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 12968 SW KOSTEL LN "'"J L NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8.32 KW PV ARRAY i\ PART TO OTHERSTHE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTIONHATH MODULES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (32) REC # REC260PEZ 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV DATE: T:(650)San Mateo, CA 638-1028 F:(650 638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A THREE LINE DIAGRAM PV 5 8/22/2016/ (868)–SOL–q1Y(765-2489)www.sdorcitycaun C AUTION': SOLAR CIRCUIT Label Location: Label Location: Label Location: (C)(IC)(CB) MAXIMUM AC 11111111111 (AC)(P01)AWARNING (P01) )Per Code: Per Code: Per Code:ode:IFC 605.11.1.4 OPEF [ NT M#XIMUMAC v NECVERTER OUTPU C 690.54OPERATING VOLTAGECONNECTION_: NEC 690.64.6.7 Label Location: DO NOT RELOCATE PHOTOVOLTAIC DC (DC)(INV) THIS ODEVICE ENT DISCONNECT Per Code: DEVICE NEC 690.14.C.2 �--;` Label Location: wA RN1NG (AC)(P01) Per Code: � � ��� Label Location: Label Location: �F TE �.. NEC 690.17(4) ARN I N (DC)(INV) MAXIMUM POWER- (DC) MINALS ON BOTH �� 4 A � Per Code: POINT CURRENT(I+rtP) 0 S VA' ELECTRIC SHOCKHAZARD MAXIMUM POWER- Per Code: THE DC CONDUCTORS OF THIS NEC 690.35(F) POINT VOLTAGE(Vmpp)w NEC 690.53 �.,>��� _ F�HOTOUOLTA[G SYST> AA ARE TO BE USED WHEN UNGROUNDEDANI MAXII U rI SYSTEM= INVERTER IS VOLTAGE(Vac} MAGI ENERGIZED UNGROUNDED SHORT-CIRCUIT CURRENT(Isc)11111111A Label Location: PV SYSTEM (AC) DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (POI) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION IN THE OPEN POSITION . Per Code: WARNING'ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 DC VOLTAGE 1S FIAZARD.DO NOT TOUCH ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGiZED IN THE OPEN POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE R ^+ Label Location: MAXIMUM AC A A N1 N (DC)(INV) OPERATING CURRENT MAXIMUM AC Mill Per Code: OPERATING VOLTAGE V ELECTRIC SHOCK HAZARD NEC 690.5 C IF A GROUND FAULT IS INDICATED ( ) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUN DEEB AND ENERGIZED Label Location: CAUTON (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 Label Location: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC AC (AC)(POI) (AC): AC Disconnect DISCONNECT Per Code: (C): Conduit NEC 690.14.C.2 (CB): Combiner Box Label Location: (D): Distribution Panel CAUTION (D) (POI) (DC): DC Disconnect PHOTOVOLTAIC SYSTEM Per Code: (IC): Interior Run Conduit CIRCUIT IS BACKFED NEC 690.64.6.4 (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED jay IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, }40t,`r 3055 Clearview Way Label Set s ■ San Mateo,CA 94402 EXCEPT IN CONNECTION I WITH THE SALE AND USE OF THE N OF SOLA/?CITY � SoIaiIiy T:(650)638-1028 F:(650)638-1029 EXCEPTIIN CONNECTI T, WITHOUT THE WRITTEN PERMISSION E SECTIVE TY INC. (888)-SOL 0)63(765-2489)50)ww638larcity.com i • ZS Comp Edge Zone Calculations 1 of 4 4Z, ZS Comp Edge Zone Calculations 2 of 4 ZepSatar3/26/15 % 3/26/15 ZeriSotar This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is beingdown force spacing= module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 Comp Mount Allowable Loads GCN portrait= 0.4 0.9 0.9 Load Duration Wind Snow design load iandscape= 15.35 27.64 27.64 psf Uplift= 656 lbs N/A " - , design load portrait= 12.28 27.64 27.64 psf Lateral= 357 lbs 290 lbs .818 note:use 10 psf minimum Down Force= 1074 lbs 771 lbs ,. OEG Snow Calculations To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing Calculations '£ Y a _4 Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 Uplift Spacingdegrees. Allowable Uplift Load FOR PAGES 1-4 uplift spacing= Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qh GCN (snow load spread over the length of the rafter) qi,=0.00256K,K,tKdV2 Basic Wind Speed= 120 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof Kzt= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.755 31.59 31.91 'psf Vorst Case Roof Pitch= 14 degrees Ko= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force iscape effective area= 13.0 ft2 GCN portrait=-1.5 771lbs in iortrait effective area= 21.7 ft2 landscape down force spacing= 39"x 31.91psf x 144f-t2 44 ft2 =89" PIandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 7711bs in portrait down force spacing= 65"x 31.91psf x 144 ft2 = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf lbs landscape uplift spacing = 39"656 27 73 psf x 144f-t2 =87" xportrait uplift spacing = 65"x 25 89 psf x 144 =56" e ZS Comp Edge Zone Calculations 3 of 4Avoto ZS Comp Edge Zone Calculations 4 of 4 ZepSotar3/26/15 3/26/15 p ` Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-0.8182 x Maximum Uplift or Down Force Pressure+79.909 lateral spacing = module width x design load Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf Ps=Cs Pf Roof Pitch= 31 45 degrees pf=0.7 Ce Ct I pg C landscape module spacing=-1.4545 x 31.91 psf+120.7273 =74" e= 0.9 Cs= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf I= 1.0 Ps= 16.1 10.2 psf portrait module spacing= -0.8182 x 31.91 psf+79.909=54" Calculation Summary Roof Pitch Spacing Check Calculated Edge Zone Spacing 27 30 31 45 Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral Force Component Lateral 30° 27° 30° 74" 48" 44" Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". a lateral spacing_ 2901bs in landscape p g 39"x14.49psf x144ftz =74" ortrait lateral s 2901bs in p spacing g _ 65"x14.49psf x144ftz =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees portrait lateral spacing_ 2901bs in p g 65"x 13.50 psf x144ftz =48" 0., '�+SoIafClty ZepSolar Next-Level PV MountingTechnology 9Y 0 `4SoiarCity ZepSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofsIII ,.% 1,2. Leveling Foot ` ' arm ud1ep ` TDteriock p d r.ea,--,t wsnr ^' - .` -r — zing Fact Part No.850-1172 , , ETL listed to UL 467 "' W.r' .-----,----:1,.--,___,,,,,„ „ ,_ ___ � of m -1 i -= Rant Attachment ,. . Away Skirl �� Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 Q`aMPAT'e , a ,,,,,,,A Nkl" ti� �F Description .- PV mounting solution for composition shingle roofs ..,� ~Fp°oMvwTev Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 • Designed for pitched roofs Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Installs in portrait and landscape orientations Illiit • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 ihr • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 iF • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps zepsolar.com Part Nos.850-0113,850-1421, zepsolar.com 850-1460,850-1467 Listed to UL 1565 This document does not create env express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Ze Solar's sol each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solei P e warranty is contained in the written product warranty for responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps.zspats.com. y each product.The end-user documentation shipped with Zep Soleac puoductp Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Solar inverters Additional highlights — RS-485 communication interface (for connection to laptop or data logger) ii / ; — Available with the optional VSN300 � ` Wifi Logger Card for easy and ' affordable wireless monitoring '°" r , — Compliant with NEC 690.12 when � ' used with ABB's Rapid Shutdown = " device r; - Comes standard with DC Arc Fault Circuit Interruptor(AFCI)to comply l with NEC 690.11 '" Technical data and types Type -� -. ---�.f,-� yA code Pitt-3.0-OUTD-US PV!-3.6-OUTD-US PVI-3.8-OUTD-US PV[-4.2-OUTD-US General speed ea#ian5 Nominal output power 3000W 3600W 3300 . 4200W ,�, a Maximum output power wattage W 3000 3300 3300 36004000 4000 3300 420080042004200 4600 4600' W.. W W W a'. Ratedgrid AC voltage W W W W W W W W 9 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input side(DC) -I : Number of independent MPPT channels 2 2 ' Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) Start-up voltage(Vstart) .._.. ..... .... ..., ..... 200V....(adj.120-350V) Full power MPPT voltage range 160-530V 120 530V OV140:530y. .€ ` �• OperatPTvoltagerange ....... ........ entx) 0.7 x Vstart 580V(>gp�53 ;Operating MPnge ,,; Maximum current(Idcmaj for both MPPT in ........... €� n d parallel, 20A 32A 32A 32A Maximum usable current per channel 10A 16A 16A16A Maximum short circuit current limit per 125A channel 20.0A 20.0A 20.0A ' ,;.. Number of wire landing terminals per channel --- - - - -- - � 2 pairs Array wiring termination , .... ........ w `� "� Terminal block,pressure clamp,AWG20 AWG6 Output.t.q�w e,+l - .Q Side(AG) Grid connection type 10/ : Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ ..........._.. .................. .. ........... 2W 0/3W 2W : 2W 0/3W : 2W 2W..... 0/3W 2W . 2W ' 0/3W 2W_. Adjustable voltage range(Vmin Vmax)(V) 183- : 211- 244- ; 183- •• 211 244- 183- 211- . 244- , 183- : 211- 244- . .......... ........... 228V 264V 304V 228V ,264V 304V . 228V ' 264V 304V i 228V : 264V . 304V Grid frequency .. 60Hz Adjustable grid frequency range Maximum current(I.,;„.;) 14.5A . 14.5A 12.0A j 17.2A ' 16.0A ' 16.0A 16.0A 16.0A 16.0A 20.0A : 20.0A : 20.0A This family of single-phase string The high-speed MPPT offers real- Highlights Power factor >0 995(adjustable to 0 8) Total harmonic distortion at rated power inverters complements the typical time power tracking and improved — Single-phase and three-phase output Grid wiring termination type Terminal b-lock, Pressure clamp,AWG20 AWG6 number of rooftop solar panels energy harvesting• grid connection ir#psrtpertee#ian devices - s enabling homeowners to get the most The flat efficiency curve ensures high- — Wide input-voltage range for Reverse polarity protection Over-voltage protection type ,..... r efficient energy harvesting for the size efficiency at all output levels allowing increased stringing flexibility and PV arra varistor 2 for each channel y ground fault detection Pre start-up R,G,and dynamic GFDI(requires floating arrays) of the property a consistent and stable performance energy harvesting Output proteci5cartdevices Anti islanding protection Meets uLl741/IEEE1547 requirements across the entire input voltage and — The high-speed and precise MPPT Over voltage protection type Varistor,2(L L,/L,'G) This inverter offers a dual input output power range. algorithm offers real-time power Maximum AC OCPD rating section that processes two strings The transformerless operation 20A 20A 15A 25A 20A 20A 20A 20A 20A 25A 25A 25A p gives the tracking and improved energy Etfciency with independent Multiple Power Point highest efficiency of up to 97.0 percent. harvesting Maximum efficiency 96.9% 97% 97% 97% tracking(MPPT). The wide input voltage range makes Outdoor NEMA 4X rated enclosure CEC efficiency 96° This is especially useful for rooftopthe inverter suitable to low-power for unrestricted use under any Ntgnd me consuting mption p y p e consumption <0 6Wema installations with two different installations with reduced string size. environmental conditions y consumption <8W orientations from two sub-arrays This rugged,outdoor inverter has — Integrated DC disconnect switch sm- terfa e Uem interfone 6 characters x 2 lines LCD display oriented in different directions,or been designed to be a completely in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger unbalanced strings(for example:East sealed unit,to withstand the harshest Standards(-S Version) Environmental. (opt.),VSN300 Wifi Logger Card(opt.) Ambient air operating temperature range 13 F to i 140°F(25 C to 60°C)with derating above 122°F(50°C) and West). environmental Conditions. Ambient air storage temperature ran e The dual-input sections with g. 40°F to+176°F t 80°C Relative humidity 0-100%RH 2(L-L,/to n Acoustic noise emission level dependent MPPT enable a more <50 db(A)a1 m Maximum operating altitude without derating optimal in energy harvesting condition. 9 6560ft(2000m) Power and productivity miimiIsm Capability enabled at nominal AC voltage antl with sufficient DC power available. for a better world"' 2 ABB solar inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Block diagram of PV€-3,813,613, 14.2-T'L-OU'T'D Support and service For more information please contact ©Copyright 2015 ABB.All rights ''"i • woINVERTER a," A9A6 ABB supports its customers with a your local ABB representative or visit: reserved.Specifications subject to dedicated,global service organization/� ,re..L 0 r, 9 change without notice. dill, I o„ in more than 60 countries,with strong www.abb.com/solarinverters ",.co.E ❑ o o o ..rye ",• II ( _.„_ U � regional and national technical partner 0 k.,-.Km I " 4— a = f__ networks providing a complete range of www.abb.com yam,}r • Rfdi ; 999 --� SF • °� life cycle services. o p ❑ 0 ❑ tonitil RESIDUAL El k , °•! oi ■ o _EQ II ■.Tr9 WIRING BOX ---v 9,ry o : .,,,.„ k t ArIR< Emo9E<o"rao�• TI1VRheiNand � °ErECT r up ■-n C US L,! usa o Mil: :c. This inverter is marked with one of the m "nE°9E"T •• two certification marks shown here(TuV E. 'Remote control function not available on-A version or CSA). PVI-4 2-OUTD-US PVI.4.2 OUTD-USS 'r - le+`P 3LWY e� m .,t94,Yx _ — — — `F a 3SM,4_ _I.__ 1 _...r te; i —200000 �.� 340V2C ,seas I ' ss 9� u �� fu 094 10% 1096 9p16 -09Ne= 50% 20gb xm6 2596 YO% _J00% �`�� %!T10 0ri0000 PGWBr +frWuwM Technical data and types Type code PVI..).0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4,2-OUTD-US Mechanical:specifications Enclosure rating NEMA 4X Cooling Natural....... atu convection Dimensions H x W x D �������� 33.8 x 12.8 x 8.7in(859 x.325 x 222mm)� Weight ....., Shipping weight Mounting system.............. ..............._. ............... � ..Wall bracket .....Bottom 2fpre-drilled( e-drilled opening for 3/i inch conduits and concentric markings for 1 inch (both sides)and 11/2 inch conduit(DC side only) Conduit connections' Sides:(2)pre-drilled opening for e/inch conduits with concentric markings for 1 inch (both sides)and 11/2 inch conduit(DC side only) Back (2)concentric markings for 3 inch and 1 inch conduits DC switch rating(per contact)(A/V) 25/600 Safety and„Compliianos Isolation level Transformerless(floating array) Safety and EMC standard UL1741,UL1741SA(draft),IEEE1547,IEEE1547.1,CSA-022.2 N.107.1-01 UL1998 UL .. .. .............__ ......... 1699B,,.FCC Part 15Class B Y ........ Safety approval pr oval ............ CSA or TUVs Regional Compliance Rule 21,HECO,NEC 2014 690 11,NEC 2014 690.12 with ABB Rapid Shutdown device Availabte models With DC switch,wiring box,arc fault detector and PVI-3.0-OUTD-S PVI-3.6-OUTD-S PVI-3.8-OUTD-S- PVI-4.2-OUTD-S- interrupter US-A US-A US-A US-A 2.When equipped with optional oc switch and wiring box. • All data is subject to change without notice II 11 ID Power and productivity Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD I ABB solar inverters 3 for better world'" ir \ ENERGIZING LIFE TOGETHER ��� 1 \E C ^ _ „"y ,, .... _ , ,.-1-;,.., - ! ! Tera r ,� 3,? € T „4.,,,,i; , d � • 3 N ''''''4,,' t r= —vim t TEMPER ATURE RA'FIh1GS a "' "` -7'<7''''' s� ; t bESeh�tt a7 1 � 3 , ph. c etc nCof .cr a ' t t mea ,--;',,;.',.."777--,,,,,----6-, , 1",,:;:.,,....L.,:„,,:,,,,, suremen s in nc es All — �� Q a�(�,s�5 � 9 3 i . .. � M v € ¢gs $ : ,'. t,. �, E1.EC7RICAC.DAp ;,;WTC REC260,50 6ENEftlaL DATA ' Nominal Power-PMvv(WP) 260 � 1 i r "' c (, !'. � �go '4 `2 ' C a '""fltU(k �r. ., : Watt ClassSorting_(WP) 5i r Ge 5 :::-:''''7;:4'-' :-*l'":.---'1 j t'''1:1'''''''0-.';';';'7''''''' yj s � s t ! t( " ss Nomina(PowerVoltage-V (V) 30.7 ,,,,— ,,,"�^° mss EK n . ,.1i:r,#( 07 fflcS11 t r° +,::'.1!-P'4 1 `" • $` . NominaipowerCurrent-IM;,;,(A) 8.50 SU �7 h sir �y • � a� s Open Circuit voltage-V (V) 0,r hl t rrtprxly€ester ntgxab � •gyp Short Circuit Current-Isc(A) 9.01 eta � G 1 �s Panel Efficiency(% 15.8 n fax P � :. rneeie�o-i<al�l a<terSucsarewunin._€ o 6.1 1',-,, ,'', 1a :J / 0 t the indicate)val 000 Vt L''2.'and Pti„�,a[standard fest conditions(STC. 4 s En 6€'. \€ r( . �°.,`�,\\\ Values at standard test conditions STC(airmass AM 1.5,irradiance 000 W/m',cell tem erasure 7TF 25"C �.� q \,... w irraAiance of 200 W/m`(AM 15&cell temperature 77°F(25 C))ar least 97%of rhe STC panel efficiency will €tit� '.. E l IPY�d(J 1 3';''''''' ''''' .54: ' �` ' ELECTRICALDATA(k?NDC7 - -\ �* REC260PEZ isfP.XIPdUP-1RAlF1G5 ° 1 `\ \ Nominal Power-P W . ', •+ s ` wrr( P) 197 4 �'1'a, a, T @ rs..® i Nominal Power Voltage-VMvv(V) 290 1®. : -\\,,, � l„� Nominal PowerCurrent-IM�,v(A) 6 81 � t8 � .�, r'lee,' � a .°: \ \ Open Circuit Voltage-Vor(V) 357 , , ` z ShortCtrcwtCurrent Isc(A) pera g ce pe (800pee ,I >€ No nlr alo tin Il tem rature NOCTw in',AMIS,winds dlm s an Ment temperature 68 F(20°C). t [ , SF6TIF CATION ARRANTv tn1 c 1ANscALDArA 0 earproduc warrant \''''\ \ \ //\'''' y v t v +lm s€ x y „ Fa ,� �, I \ � ���eDas 25yearlinearpoweroutputwarranty i IrWt (max.degression in performance of 0.7%p.a.). - UL 1703,Fire rating:Type 1,Class C REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing i:s_':',,,,,'.4'7r7::..i;:.j::,:::;',::..ti'lr,miart;:::::7:::t17:i'.1_,3::!,i,7e,p,ji!:,,r4,,4:7„.P:;::ittH'.,,,,j4.,,,,lit,\\:.'4717T \ z.,,,\/:\ \,...\\,..,.\\\,,,,,,,,, products,services and investments for the solar industry.Together with our partners,ex create value by providing solutions that better ''''-e," C C r- \,,,,,,,4,,._;:kiZier.'43'''''' ' \\\ meet the world's growing, \\N ‘ \ \ \ \ \ \ energy needs.REC is headquartered in Norway andlistedonthe0s(oStockExchange(ticker.RECSOL).Our1,600 `q empl0yees worldwidegenerated revenues of USD 647 million in 2013. \ \ ' \ .- \ . \,'"-- \ s www.recgroup.com • A>, '"^SolarCity ZepSolar Next-Level PV Mounting Technol ___ DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE ____________.---- CI � DWV DEBRIS GUARD —.- COMP ROOF MOUNT :����/�/ COMP ROOF ������ i 9 ' , DWV Debris Guard Construction Detail Debris Guard,close up l...0: �GOMPgp4`� Prevent blockages and keep vents open with the DWV Debris Guar . 0 . Protects against: ~FA 4; • Leaves • Rain c'OMPPZ • Pine needles • Insects • Snow • Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. 0 ...44. zepsolar.com tv This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The c lely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1677-001 Rev A Date last exported:April 3,201