Loading...
Plans (46) RWEI Y ED JUL 02 2013 CITY OFTIGARD CITYOFTIGARD Approved *,),:t..6-&-:-.-.....—....[� BUILDINGDNISION Conditionally Approved......----[ j PROJECT INFORMATION See Letter to:Fol low... [ -------------_AttaAed- ---------..1---1-,_-— ____- OWNER SKACH RESIDENCE CONTRACTOR ADVANCED ENERGY SERVICES PermltN mbeL' `b • 0 / 1/ /./.,3 10260 SW HOODVIEW DRIVE 14755 SE 82ND DRIVE Ad. ,,:s: O _./ `'=•_•'A►it ,� I. / ((V// TIGARD,OR 97224 CLACKAMAS,OR 97215 MAIN:503-635-0117 By: 11Erigh. Date: JIM C ""'S CONTACT:RON BURDEN BUILDING SINGLE FAMILY RESIDENTIAL PHONE:503-806-3719 \_, DATA APPLICABLE 2010 OREGON SOLAR INSTALLATION ROOF SPECS ASPHALT COMPOSITION ROOF(SINGLE LAYER) ,>, "roved plans SW HOODVIEW DRIVE W/2X6 COD ES SPECIALTY CODE ROOF TRUSSES TILT: DEGREES ATILT TO SOUTH:10 DEGREES shall be on lob site AZIMUTH:189 DEGREES SYSTEM SOLARWORLD 270W (11 MODULES) ROOF AREA(PLAN VIEW)= 2,570 SF (11)X 270W=2.97kW ARRAY AREA= 185 SF, ARRAY IS<25%OF ROOF AREA OFFICE COPY DRIVEWAY (11)ENPHASE M215 INVERTERS, • "r 1 INVERTER AT EACH MODULE MODULE SOLARWORLD SUNMODULE SW 270W MONO twgNMEr.. SPECS (L)66°X(W)39.5'X(H)1.34' WEIGHT:47.6"LBS COMBINED WEIGHT OF MODULES AND RACKING IS< • •� • IN , 4,5 PSF. PROJECT NOTES EEO ' 1 1. 303,2-PV SYSTEMS AND SUPPORTING STRUCTURE 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED i. m SHALL COMPLY WITH REQUIREMENTS OF OSSC WOOD CONSTRUCTION WITH 2X6 TRUSSES AT 24" 0,C, i I CHAPTER 6 OR THE ORSC AS APPLICABLE. MAX. EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS L J 2. 303,3-ALL PV MODULES TO BE UL 1703 LISTED. IN TABLE 305,4,1, - 3. 303.5-PV SYSTEM SHALL HAVE A FIRE 8, 304,9.5-DISCONNECTS,J-BOXES,COMBINER BOXES OR CLASSIFICATION THAT IS EQUAL TO OR GREATER GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED Area:of Vdprk . THAN THE ROOF ASSEMBLY REQUIRED BY OSSC PATHWAY OR CUTOUT. `PV.array.. . — SECTION 1505.1. 9. ROOF MATERIAL IS ASPHALT COMPOSITE ROOF. 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE 10. PER 305.4 ITEM 3:TOTAL SYSTEM WEIGHT SHALL NOT ' .. • RATED FOR THEIR USE, EXCEED 4.5 PSF, PV MODULES AND RACKING SHALL BE 5. 303.4. 304,8-PV LAYOUT SHALL NOT RESTRICT DIRECTLY ATTACHED TO ROOF FRAMING AS SHOWN IN EGRESS, LIGHT,VENTILATION,OR ROOF DRAINAGE CONNECTION DETAIL#2.ATTACHMENT SPACING WILL REQUIREMENTS. BE 48" 0.C. MAX,AND WHEN ATTACHMENT LOCATED ` ' ' 6. 304,9,1 GENERAL PATHWAY REQUIREMENTS- WITHIN 3'OF ROOF EDGE,HIP, EAVE, RIDGE SHALL BE • • EXCEPTION 1: ON STRUCTURES WITH A PV ARRAY 24"O.C. MAX. AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF 11. MAX MODULE HEIGHT< 18"OFF ROOF SURFACE. WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN 12. SECTION 304,7-MECHANICAL EQUIPMENT INTERSECTING ADJACENT ROOF AND WHERE NO CLEARANCES: NOT APPLICABLE,THERE IS NO SECTION IS LARGER THAN 150 FEET MEASURED IN MECHANICAL EQUIPMENT WITHIN OR ADJACENT TO LENGTH OR WIDTH. AREA OF WORK. EXCEPTION 1A: WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF I lar I� AREA OFA STRUCTURE,A MINIMUM OF 12" UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. NORTH0 � — 1 . SITE PLAN ADVANCED ENERGY SERVICES DATE: JUNE 26, 2013 PROJECT 4: SKACH Scale: 1" • 30'-0" 0' 15' 30' 60' 14755 SE 82ND DRIVE CLACKAMAS, OR 97015 SKACH RESIDENCE • 10260 SW HOODVIEW DRIVE 503-635-0117 rIGARo,OR s7zza CCB# 180882 DWG. 1 OF 3 Ar'ACHMENTS SHALL BF SPACED NO i . . GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS LOCATED WITHIN 3 FEET OF A ROOF EDGE,HIP,EAVE OR!RIDGE, , . . . . , , . . . . , . , • , . ' . . ; . . , . ' ; . . . . , , . . , . . , . . . . . , . . . . . . . . , . . . . . . . . . . . . : ISISC:305.4,.3(B,. . , . . : . i , 1 \ , i , ! , ; 1 i , I I 1 . , . 1 , . . . ! :2X6 ROOF TRi1S5 . . ' : ' • . . , . , . . . : ; . . . 0 24 C., t!f) '' . . . . : , . • . . . . . . . . . , . . . , • . . : ! ! , . • : ! ; ' . . . . . 19r-0" . . , , ! • 12" ; ! , . . . . : . ' ! , ' ' • ; ' , ! I i ' I . ' ! 1 I • '" '''' ..4'. ."'". .'1". 7 7 --"! i , 71*-7"--H: 1 I __I ! ; . . , . i I ....7 t.• , i, t I , . ; I • . , ; NI ; ___I i ..•.r. 111',,,,-,---4-- ',,,-4.-, , ; . ,/ .....ip,—..—:4.---.4......... , t ' ‘1 I ' s o LAP,' . 1 • , A RRAY . : ' ' -1 - IT - 4 ': •',---,4.4 ,-,, _,,,-1. - ,. . • ;.i , , , 1E 1... . I- „.- . 1 . . . . EXISTING ! ; . . . ! . , ,, ! CHIIMNEY ! ! - "1! ' :.1,- ' '' l'..,!`-':!,"! , . ' . .... 1 : ! / -,,,!"-,-.**-4-----,--.. -----40,---,, ! . . . ! . ! . --- :!1' -- 4.. I ,c) 1 : . : . , , , ' ,.. • . : . . N '-' ; : . . EYE SUN 1 , .. . ,. .,.. :, ..'r . , READNG,TYPJ. , 1 , : . , • / ...;,...,,,,...,..„.„......., , ;ATTACHMENT I CONTNOECTRoIONdF :RAILS,TYP ., 1 - .-, '',..'.,;-' - •!:- "!-- - , . * . ' . : ! TRUSS,TYP. . . , I - . nf,i1 . . . ., . i 1 ,• ' , • . , , . . . ; i' 0 , • . --, --1 ,,,-- 4,-..` 7 sc- #---- ''''7t4-------4.11r."----, ,„.1, -t, ".,,..1"!!' --' t.'.. I! _ I - 4-!..,I - „ ,'4 i •Ig„ • TN- t- Ir-.:6.4,.........„+.....„1„..,. 1--..--.., ,., 1 L , z. • . . • • , . • -\ . • , ...J . . • . • Area of . • 0 REFER TO . . . . • ' DRAWING 3 , • • ., FOR ROOF . Work . • . • . . . SECTION,TYP. . ' . • • • • • . . • , . ! . . . N ADVANCED ENERGY SERVICES DATE: JUNE 26, 2013 PROJECT #: SKACH 1. ENLARGED ROOF PLAN = ' 14755 SE 82ND DRIVE s,aie: 1/4" 1 -0" CLACKAMAS, OR 97015 SKACH RESIDENCE 10260 SW HOODVIEW DRIVE 503-635-0117 CCB# 180882 TIGARD,OR 97224 DWG. 2 OF 3 SOLAR COLLECTOR MODULE MODULE(4.5 PSF,MAX.) DIMENSION i VARIES � ` _ �*.nrrf -.i, lid I .. , II 1 c • f0 y , MODULE DIMENSION I ,, X. . 10'MAX I hin... ' i SECTION A I 1 N►'I. � I " SECTION A H � _r 010,t` 11 CONNECT SOLAR MODULE TO +44 " RAILS WITH 1 CONNECTORO'WI i FOR EACH 8.SQ FT.OR t LESS OF MODULE SURFACE 1 I q I I I e� it 1 CORROSION RE5ISITANT METAL RAIL ANCHOR I .. , ' TO ALTERNATE ROOF FRAMING 48"MAX.ON ,..�. ce CENTER PER SECTION A-A 11 n "�, ''� TYPICAL,PROVIDE A Nn 1 MINIMUM OF 2 RAILS I I 1I PER MODULE 1 I I1 NEW SOLAR MODULE 1 I ROOF Fyzp,M51NG �^ ARRAY AND ATTACHMENT --,1.------r-0 48"t'Ip(ON CENTER I SYSTEM TO EXISTING ROOF TRUSSES,TYP. .1$¢ 2. CONNECTION DETAIL r / _ Scale: NTS COLLECTOR MODULE CONTINUOUS SUPPORT RAIL AND CONNECTION POST BV RAIL — Aiiiiihopp", / FLASHING MANUFACTURER INSTALLED PER 10' EXISTING 2X6 MANUFACTURER'S r.. TRUSSES INSTRUCTIONS ' ®24"O.C.,TYP. <s, ,, AlliV 1 . SECTION EXISTING WOOD 5/16"HANGER BOLT ROOF RAFTER Scale: NTS OR TRUSS SUNMODO ALUMINUM STANDOFF 024"O.C. 1 1/2"DIA.,OR APPROVED EQUIVALENT AND SUNMODO TILT UP ATTACHMENT,TIP, 3. CONNECTION DETAIL ADVANCED ENERGY SERVICES DATE: JUNE 26, 2013 PROJECT #: SKACH Scale: NTS 14755 SE 82ND DRIVE CLACKAMAS, OR 97015 sKACH RESIDENCE 10260 SW" 503-635-0117 TIGARD OR 972EW24EW DPIVE cm 180882 DWG. 3 OF 3 . Skach Residence NEC PV LABELING REQUIREMENTS EQUIPMENT SCHEDULE/NOTES: 2.97 kW Solar PV System AC CIRCUIT BREAKER(690.64) {1)PV ARRAY,it SOLARWORLD 270W MODULES (2)EACH MODULE CONNECTED TO ONE M215 ENPHASE MICRO PV Array (11) Solarworld SW 270 Watt PV Modules ARNING:CIRUIT BREAKER IS ENERGIZED FROM TVWOSOURCES CSOLAR SYSTEM AND UTILITY GRID. INVERTER. PPERS GEc/EUPNONENPHASEMH RCUIT. 36AWGBARE VERTERGEC/EGCANDEBRANC M215OUTPUT CIRCUIT WIRES (4)SOLADECK ROOFTOP JUNCTION BOX.TRANSITION TO THWN-2. (5)UTILITY GRADE METER TO MEASURE PV OUTPUT MAIN SERVICE PANEL (6)GRID INTERCONNECTION BY 15ATWO POLE BREAKER (1)(2) (8)UTILITY MET RY ELPANELAIN SERVICE ASEMENT OCATED ON EA TEXTERIOR WA B 0 0 o AC POINT OF CONNECTION (9)GROUNDING ELECTRODE CONDUCTOR CONNECTED TO 0 0 SOLAR ELECTRIC SYSTEM EXISTING BUILDING GROUNDING ELECTRODE. AC OUTPUT CURRENT:9.9A NOTES: NOMINAL AC VOLTAGE:240V 0 0 -THE SUM OF THE RATINGS OF BREAKERS FEEDING ANY PANEL MUST NOT EXCEED 120%OF THE RATING OF THE PANEL BUS BARS WARNING (NEC)690.64) 0000 INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 10 awg USE-2/RHW-2 (3) ' Sunlight Resistant Wire plus THIS PANEL IS FED BY TWO SOURCES OF POWER One#6 AWG Bare Copper GEC/EGC 1-UTILITY 2-PV INVERTER AC Voltage Drop Calculation 1.Internal Voltage drop within cabling:11 micro inverters=.35% Roof Exterior(4) 2.Voltage drop from branch circuit to dedicated OCPD:N/A , PRODUCTION METER 3.Voltage drop from OCPD to Main Service Panel ` %Vdrop=(0.9A*11)*(2*4Oft) CUSTOMER OWNED SOLAR GENERATOR OUTPUT =(864*(.00124ohms/ft))/240V =0.0045*100 =0.45%AC Voltage Drop LB TOTAL AC VOLTAGE DROP:0.35%+0.45%=0.80% Exterior South Wall Approximate distance from Project: 10260 SW Hoodview Dr roof top array to Main Electric Panel is 40 feet. Tigard, OR 97224 3/4"EMT outdoors with 2.97 KW SOLAR PV SYSTEM (2)#10 AWG THW N-2 conductors w/(1)#10 Solar Contractor: THWN-2 Neutral and(1)46 3/4" EMT from Output meter Advanced Energy Services GEC/EGC to Main Electric Panel. Conduit runs down exterior south wall and Distance less than 10'. 200A Main Panel penetrates house at first floor utility room. / Pv (7) Production Meter No Main Utility Meter Breaker 120/240 Volt, Title: � v� three-wire,single-phase Single Line Diagram,Grid Tied Solar PV System House Exterior House Interior ' I 4 / 1'Utility (9) DATE: 6/13/13 DRAWN BY: Ron Burden (6) M PROJECT/Customer Name: 15ATwoPole � Grounding (8) Drawing#:0001 Skach Residence [� (5) Backfeed Breaker """'"""ti"'` Electrode REVISION HISTORY DATE NOTES #6 bare copper GEC