Plans (47) l G 1 GENERAL NOTES PROJECT INFORMATION VICINITY MAPRECE\\JEO Zz ° W a w > . 12°13 CD (0 0 MAS W Z2M � z�^ R�® O °�'N PROJECT LEGAL: OFTtG z. 1. ALL WORK SHALL BE DONE IN CONFORMANCE WITH ALL APPLICABLE CODES AND TO THE , ,� w4. } o HIGHEST STANDARD OF WORKMANSHIP FOR ALL TRADES INVOLVED. , � ► �w co= OWNER: HUYNH, LEN ' S 1 .L 2. TYPICAL DIMENSIONS AT NEW WORK ARE TO FACE OF STUD AND/OR FACE OF CONCRETE, 4 u) 0 3 UNLESS OTHERWISE NOTED. DIMENSIONS AT EXISTING CONDITIONS ARE TO FACE OF FINISH, ADDRESS:8144 SW STEVE ST n J x AND ARE SHOWN FOR REFERENCE.WHERE NEW WORK MEETS EXISTING WORK, ALIGN NEW TIGARD OR, 97223 :: 71 :14z-241g1j10' '''''' 11:j 'i :11j , a-14:1 ' I WORK FINISHES WITH EXISTING FINISHES,TYP. ; STATE ID: 1S136CB07800 , 3. IN THE EVENT THERE IS A DISCREPANCY IN THESE DRAWINGS WITH THE ACTUAL FIELD PROPERTY ID: R977811 CONDITION,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY DESIGNER FOR DIRECTION PRIOR IA I i i TO THE CONTINUATION OF THE WORK. COUNTY: WASHINGTON COUNTY : .,, 42 ZONING: R-4.5 �, Z 4. DO NOT SCALE WORKING DIMENSIONS FROM DRAWINGS. IT SHALL BE THE CONTRACTOR'S i ALLOWED USE: SINGLE FAMILY w > { (— RESPONSIBILITY TO CROSS CHECK DETAILS AND SHOWN ON THE DESIGN DRAWINGS WITH r - RELATED REQUIREMENTS ON THE CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING i Q AND OTHER DRAWINGS AS APPLICABLE, NOTIFY DESIGNER OF ANY DISCREPANCIES BEFORECC 4 PROCEEDING WITH WORK. SITE COVERAGE DATA: = 0 LOT NUMBER: 31 Z 5. CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS Z SPECIFICALLY INDICATED OTHERWISE.TYPICAL DETAILS NOT REFERENCED ON DRAWINGS LOT AREA:7,500 SOFT. Q APPLY UNLESS OTHERWISE NOTED BY SPECIFIC NOTES AND DETAILS.WHERE NO SPECIFIC BUILDING CLASS: DETACHED SINGLE-FAMILY HOMES CC DETAIL IS SHOWN,THE CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO WHAT IS W INDICATED FOR THE TYPICAL CONSTRUCTION ON THE PROJECT. FOUNDATION TYPE: CONCRETE IZ HVAC TYPE: FORCED AIR a6.WHERE NO SPECIFIC STANDARDS ARE APPLIED TO A MATERIAL OR METHOD OF CONSTRUCTION TO BE USED IN THE WORK, ALL SUCH MATERIALS AND METHODS ARE TO TOTAL LIVING SPACE: 1,080 SOFT. MAINTAIN STANDARDS OF THE INDUSTRY. ELEVATION: PROJECT DIRECTORY A- 1 : INFORMATION SHEET '_ 7. MATERIALS, EQUIPMENT, NOT INDICATED ON OR SPECIFIED HEREIN BUT REQUIRED FOR YEAR BUILT: 1979 THE SUCCESSFUL AND EFFICIENT COMPLETION OF THE INSTALLATION SHALL BE HELD TO BE ROOF COVER TYPE: COMPOSITION A-2 : SITE PLAN IMPLIED AND SHALL BE FURNISHED AND INSTALLED FOR NO ADDITIONAL COST. CD N A-3 : AS-BUILD FLOOR PLAN N MINIMUM SET BACK: > 0) 8. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS OR A 4 : PROPOSED FLOOR PLAN W ROOF, LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. FRONT: 20 FT. O SIDE FACING STREET ON A-5 : ELEVATIONS 9. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL,AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS,AND PRIOR TO CORNER&THROUGH LOTS: 15 FT. A-6: ELECTRICAL PLAN Q CONSTRUCTION. SIDE YARD: 5 FT. ' C. S- 1 : FOUNDATION & ROOF FRAMING c0 R. 10.WHERE EXISTING CONSTRUCTION IS CUT, DAMAGED OR REMODELED, PATCH WITH REAR YARD: 15 FT. MATERIALS TO MATCH KIND, QUALITY AND PERFORMANCE. DISTANCE BETWEEN PROPERTY S-2: SECTIONS CITY OF TIG e D ,� LINE AND FRONT OF GARAGE 20 FT. S 3 : DETAILSApProved 7�pf �� ��J [til PERMIT SET x MAXIMUM HEIGHT 30 FT. Conditionally Approved [ ] A, DEMOLITION NOTES See Letter to:Follow [ I MINIMUM LANDSCAPE REQUIREMENT:20% Attached. ] REVISIONS: w 1. ALL DEMOLISHED MATERIALS ARE TO BE SALVAGED FOR REUSE WHEN POSSIBLE. IF Permit I bey- kl `�?_dt't ` MATERIALS CAN NOT BE REUSED ON SITE, MAKE THEM AVAILABLE TO OTHERS FOR REUSE. 4freid Address* 0 ( .4A) I- PROJECT CONSISTS OF: i J t ( • CHECK SHEET By: ��i. Date: 1 2. PROTECT ALL EXISTING ELEMENTS TO REMAIN FROM DAMAGE DURING DEMOLITION WORK. ATTACHED WHOLE UNIT INCLUDING: ONE BEDROOM, c13\\3 DATE: 03/19/2013 3. INSTALL TEMPORARY SHORING AND BRACING TO REMAINING STRUCTURES AS REQUIRED LIVING ROOM,CLOSETS, BATHROOM,WINDOWS, 1 Approved ins DURING DEMOLITION DOOR, PORCH COVER, FLOOR AND ROOF ETC. shall be on job side A - 1 0. OFFICE COPY SCALE: VARIES J C Z o 0 U J W >a 2 23n OWN W _ _ _ F07 • w LU m 27'-8" / I I W Ci zo - iN, r4 �. 29' 6" .GRASS . . . jj *-15.-2" \ I '/1 EXISTING \ ( A ) . . . . ....-- iN ;re. / I GRASS Ai I0/ 0 J . (._/ — — — —G- — 24'-4" H u) i �1 , o i. / EXISTING EXISTING LLJ iii \) . ..-)1\\\ 41 • - • - ADDITION co 4401, **- --\. -- Nk \ T M N d Q � � F GRASS GRASS 'QV ~Iio \' PERMIT SET �`� - ' IZ � ��1 - • v \ • ,I� �IIi►1 �� -AN CHECK SHEET ,;,..,� DATE: 02/26/13 SITE PLAN AW TC.1 01111." Scale: 1"= 10'-0" A - 2 SCALE: 1"=10'-0" 1 C F 1 45'-4" / t zo 0' U Z J W ra 70 2 za^ O O L a LT; = UWv O 1- $ 2 M W mo in W z= ?� w co ¢w o� o 00 11 r,- n • Pri Z v EXISTING ROOMS Q Zn :1- \ N cc O o> J LL 0 \ J_ D \ CO io r� 5'-2" a) Q 114° • T • • t ro / 12' / 15'-5.. 2' Jr r_ 1— co L (A N l' W N 30'-2" N. > 0)) / W H CC '0o Ln p r o co CC EXISTING GARAGE 'v 't 0 EXISTING PATIO N N • co I— N N PERMIT SET REVISIONS: (4 01) N `� C CHECK SHEET DATE: 03/19/2013 \ \ \ AS-BUILT FLOOR PLAN 12'-2" 20'-4" A - 3 Scale 3%6"= 1'-0" SCALE: 3/16"=1'-0" J 13'-6" i / Zo o U 0 ,f,_,i W }< -=,�;{�'''� In W Z5) \ \ \ 0 60"x 36" Lu z 0 M 2 Z6n _ - it Oz ocp,o. ill I- >- TABLE N1101.3 m o SMALL ADDITION ADDITIONAL MEASURES(Select one) W Z o aw Increase the ceiling insulation of the existing portion of o v BEDROOM 1 the home as specified in Table N1101.2. a O •\ x �F r 13'x 10' 2 Replace all existing single-pane wood or aluminum windows to the U-value as specified in Table N1101.2. in Insulate the floor system as specified in Table N1101.2 3 &install 50 percent of permanently installed lighting fixtures as CFL or linear fluorescent or a min.efficacy of -N.,- 40 lumens per watt as specified in Section N1107.2. z N CL J EXISTING WINDOW 4 Test the entire dwelling with a blower door and exhibit J 3 '4" no more than 7.0 air changes per hour @ 50 Pascals. 0- \ \ \ / EXISTING RO( 5 Seal and performance test the duct system. � �,� 6 Replace existing 78 percent AFUE or less gas furnace O with a 92 percent AFUE or greater system. 1>::A N NZo \ 7 Replace existing electric radiant space heaters with a LI- N I ductless mini split system with a minimum HSPF of 8.5. W 8 Replace existing electric forced air furnace with an air U) \ \ source heat pump with a minimum HSPF of 8.5. 0 0- io 9'-8" 9 Replace existing water heater for a natural gas/propane 0 '� BOOKSHELF water heater with a minimum EF of 0.67. CC M0- `A10 Install a solar water heating system with a minimum of \ 40 ft2 of gross collector area. Ili CO CO LIVING ROOM 16'x 8' \ s. -- v 0 11.7 1 1 NN 1 2 CO C_ W (.;L 2 cLFmaiiii V) O 60"x 60" \ \ \ �� \ -� U) Q ''� 0 411$ ® ® EXISTING PATIO EXISTING GARAGE 1— I— EA 5,-9.. 4'-3" 3' 3 1' 6" , PERMIT SET /-i / / / / . p....__47 1, 10' 1, 6' 1;1' 6"I REVISIONS: 17'-6" I CHECK SHEET /i 1 1' y �— `� DATE: 03/19/2013 PROPOSED FLOOR PLAN A - 4 Scale 346"= 1'-0" SCALE: 3/16"=1'-0" r r 1 ® Zo 0 U Co W Q ±15'-2" NEW SIDING TO MATCH EXISTING ASPHALT SHINGLES TO MATCH EXISTING z Co m 2 O r- ±1 3P-5" O o(N - - t 1 I , 12 1 1 1 1 , 1 I , 1 1 I 1 2 U`7 I I I 1 1 I I I I I I W 1 I I I I 1 l I 1 I f F- YmM 1 r til I I I I I I f 1 1 1 1 1 1 1 1 1 I 1 1 1 1 W m 0 Fri I I f I I I I I 1 I I 1 I 1 I 1 I 1 I LU z H 6 I �� w 1 1 1 t I I I 1 1 I Q l 1 1 1 I 1 I I I I 1co 1 1 1 1 1 1 1 1 1 1 1 I I I 1 1 I I I 1 1 X I * : ' ' : 'iHH I I 1 I 1 I I 1 1 I I t6'-6" NEW PORCH COVER • NEW 4"x 4" POSTS (J) ±0'-0" .- 3 W NEW 60"x 48"WINDOW SOUTH ELEVATION NEW 36"x 36"WINDOW i I Scale:3/6" = 1'-0" .11 ASPHALT SHINGLES TO MATCH EXISTING 2-2 2-2 ASPHALT SHINGLES TO MATCH EXISTING S-2 EXISTING EXISTING S-2 ±15'-2" t15'-2" 111111111 1 1 1 1 1 1 1 1 II I 1 1 1 I 1 1 1 1 1 1 — 1 1 I 1 1 1 1 1 1 111111111 1 I I I I I I I 1 1 I 1 1 I 1 1 1 1 , 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1. , 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I , I , ' I , I , 1 , 1 1 1 1 , 1 , 1 , 1 , 1 I 1 1 (-1) ^ M ±13'-5"— — — 1 1 1 I I I I I I 1 I I I 1 1 1 1 1 1 1 1 11 I I I 1 I 11111111111 I V I N —N 11211I1I1I1 IIIIIIIIIIIIIIIII1III1III1. 11i W 1 I I I I 1 III 1 1 1 1 1 1 /\> C) -----� Irmo= -- 1 1 I I 1 I I I I I I I I --- 6` I 1 I 1 I I I 1 I I I I I 1I J 1 I 1 ' 1 1 I 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 ''/�^� L.L MMI MINIM/. `__ l I I I 1 I I 11111111 VJ O �� ��� J 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 �� 12 -.1 II I 1 1 1 1 1 1 1 1 1 1 1 0 C II '� I I I 1 1 1 I I I I I I I I 1, ±8'-6" r- 1._ ( I 1 1 1 1 1 1 1 1 1 1 1 ±8'-6" Cl') cC — — — — 6 IN1701%444,410 — — — Q / fr .1- 0 CO I— r I ' - PERMIT SET REVISIONS: - t0'-0" f0'4)" )_ CHECK SHEET NEW 60"x 60"WINDOW NEW ADDITION NEW ADDITION — NEW 60"x 36"WINDOW DATE: 03/19/2013 EXISTING WINDOW NEW SIDING TO MATCH EXISTING A - 5 NEW SIDING TO MATCH EXISTING EAST ELEVATION WEST ELEVATION Scale: X6"= 1'-0" Scale: 3%6"= 1' -0" SCALE: 3/16"=1'-0" r \� 18"x 6" SCREENED %"CDX PLYWD. SHEATHING %"CDX PLYWD. SHEATHING z o VENTS TYP. STAGGERED LAYOUT TYP. STAGGERED LAYOUT TYP. w >a 13' 6" "o 3Ys"x 6"GLULAM BEAM 20 3' 1' o max B 0 >2� / _ '� w mom —, — w Z=-- 17 / A VA— — — _ r�� I-- — ------- .W co E % I 3%"x 6" GLULAM HDR. X \ia g a T o ' N EXISTING ROOF 1 Lu ATTIC ACCESS 22"x 30" U) 2"x10" CO 16"O.C.TYP. /, _ Q {' - —J EXISTING FOUNDATION ri OL d L - J Z CUTMIN24"x16" HOLETHRU a ' Q EXIST CONCRETE FOUNDATION pc I. < N WALL TO ALLOW FOR FURNACE w T U_ co DUCT WORK AND ADDITIONAL z i EXISTING ROOF CRAWL ACCESS I 3 Ye"X 6" GLULAM HDR. ...5 , it I 8" 4% 24"x 24"x 12" CONCRETE PAD = ucLii PROVIDE 1 FOUNDATION IGIRDERTRUSS 'r' ® II _ VENT WITHIN 3 FEET OF EACH 1 / , i— co 6' 5" CV II- 6'-5" L ��— \ CORNER OF THE BUILDING / / / W j > rn „ I / w 3Ye"x 9" GLULAM BEAM 8 �� PROPERTY LINES SHALL BE PRE-ENGINERRED GA3LE TRUSSES 24"O.C. _ Cl) Q 22°x 30°CRAWL ACCESS _, I I 00 CLEARLY IDENTIFIED PRIOR RED / I / I—� TO FOOTING INSPECTION . Q1 �J, 3Ye"x 6" < xis L GLULAM HDR. 1 0E 1 JAI co L �///////h--F�// //�(////A_- // �� _— - maxax �/ NEW FOUNDATION WALLS r 1' 17'-6" - — — - /- - PERMIT SET ® \181 ao 18"x 6" SCREENED - — — - `� VENTS TYP. EXISTING FOUNDATION WALLS --N-- REVISIONS: - — — - 1" x 6" FASCIA 8' CHECK SHEET 11111111111111111111111111111 FOUNDATION WALL TO BE CUT THRU 2"x 6" RAFTERS DATE: 03/19/2013 FOUNDATION FRAMING PLAN ROOF FRAMING PLAN Scale:=%6"= 1' -0" Scale: =3%6"= 1' -0" S - 1 SCALE: 3/16"=1'I .0" f r 1 ASPHALT SINGLES OVER 30#TAR EXISTING ROOF z PAPER OVER%a"CDX PLYD. TYP. Z I I I 1 1 1 1 1 1 1 1 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 W i MI IMIIIIIIIIII MI=11111111111111111111•11111111111111 MI=MOM= IMIIMI=MIIIIIIIIIII CD (_,02 MIIIMIIINIM R-38 BATT INSULATION TYP. 011��������� 1I 2 MIINM MIN IMM W z O m -�----�—_— ,� ��I �� INIM 2 6 n PRE-ENGINERRED TRUSSES @ 24" O.C. 1����� �� _ W CI.I. ��������� M ��� I— i-M o -.1111M1= W MOS 6" SHIPLAP SIDING OVER RAINSCEEN. Ni1' 1' EXISTING SIDING - OVER BLDG. WRAP. OVER Y2"CDX 7 PLYWD. ON 2"x6" STUD @ 16"O.C. II W/R21 BATT INSULATION ao 2"x 10" FLOOR JOIST @ 16" O.C. LIVING ROOM fve'.0 Cyt .4yt 4y pp pp,4pI !40 pp 4y� y — w i, Et iZ Op - 0;:•:...;.:;,..•:..91 a, I ( 4"x 4" POST �a4 , 6" SHIPLAP SIDING OVER RAINSCEEN. 0 Z0� ' T _l / _Atli O//O,/� OVER BLDG. WRAP. OVER Y2"CDX I- /✓/✓✓/ ✓ /✓ `�✓;?" � �� '�/ / y,/ ; / ' �OU .006 BLACK VAPOR BARRIER PLYWD. ON 2"x6" STUD @ 16"O.C. w 3 y8"x 9 GLULAM BEAM W/R21 BATT INSULATION U) UNDISTURBED SOIL 24"x 24"x 12"CONCRETE PAD TYPICAL 1 - 1 DETAIL Scale: 3%6"= 1'-0" ASPHALT SINGLES OVER 30#TAR PAPER OVER 5/"CDX PLYD. TYP. 12 GIRDER TRUSS PRE-ENGINERRED TRUSSES @ 24"O.C. 6 PRE-ENGINERRED TRUSSES @ 24"O.C. \ i •. a r a (A N R-38 BATT INSULATION TYP. W N 2"x 6" RAFTER 40010110 WE- OC `6� �.,�,'�1�����������k��,��������� CM-y �� _ I-� /r 4"x 4" PRESSURE TREADED POST 0 IA ® s l 1' �! _I Q BOOKSHELF • �. 0. 6" SHIPLAP SIDING OVER RAINSCEEN. —N1/4. 1 ,j, 00 1- OVER BLDG. WRAP. OVER Y2"CDX coEil0 T PLYWD. ON 2"x6" STUD @ 16"O.C. 00 I I I I 4, 36'' W/R21 BATT INSULATION __ — — BEDROOM LIVING ROOM \-6-. PERMIT SET zo 2"x 10" FLOOR JOIST @ 16" O.C. co 1 _ _ I� r �� �� ����I��������� REVISIONS: Iani 4 ^���� , 4 N 1 M R I � •� 4"x 4" POST �! i`�!i`�!i`�ii`�,/�ii`��i`�. Too ww.',• .,.-,..•2, .006 BLACK VAPOR BARRIER _ow a, ; �✓/✓/✓/✓/✓/•//✓/�j✓/• CHECK SHEET °°4' .'. .�.,�►q I Jul .%��%��%�%��%��%��#��%�,. • . .*J.''-i 71, ^'� .�. .�. ..�. i i i g q i i q i i i i i i i•.-i i i' i �i �`�I�`�/���/�`�/�`Q�`�I�`�/�`�/�`�%. /��/��/ ���i ��//�� �� *�� ������/Q/ ��/��/��/ ��/��/�/���������/����/�i�� .� �� - .� .� .� . ��/�������������������� DATE: 03/19/2013 — 4"CONCRETE PAD UNDISTURBED SOIL 3 Y8"x 9" GLULAM BEAM TYPICAL 2 - 2 DETAIL S - 2 B-B 24"x 24"x 12" CONCRETE PAD S-3 Scale: 346"= 1' -0" SCALE: 3/16"=1'-0° -9 C . - 1 12 0 o EXISTING WALL Cl) ;a 2"x 6" RIDGE BOARD ASPHALT SHINGLES OVER 30#TAR 6 �� o 0 [IF PAPER OVER%"CDX PLYWD.TYP. / wzz2"x 6" RAFTER j = 0 o TrO OcoaPRE-ENGINERRED TRUSSES @ 24 O.C. W-- M\ �1 3/s" HARDWOOD �- w m o 8: :: " " BEAM I�II ? FLOOR % o WR7= : /4" PLYWD. R-38 BATT INSULATION TYP. ��/ oxi 3' SHEATHING /-- i g " P.T. POST 11" --. INSUL. BAFFLE TYP. �� , ' �II.II, DRIP FLASH __________ -101101.„-- 1‘11 METAL BRACKET 1 ,i'' 2 x 10" FLOOR 1 1 HURRICANE TIES EA. TRUSS TYP. 1 GUTTER TYP. ►� JOIST @ 16 O.C. ' 1� 12"x 12"x 24 FOOTINGNI1111 = 2"x 6" DOUBLE TOP PLATE° �� 1"x 6" FASCIA TYP. J �'w*' ' ,.,.,_.,.,. 2 x LEDGER W/Y2" DIA. ✓/��/�/�/��� ��\�/��/�\�/�\�/�% EXPANSION ANCHORS Ii a �i\\O\\moi\\�i:�� \\>p�\\�\\�\� I— OOO� ��!�/�O�O STAGGERED AT SPACING 6" SHIPLAP SIDING OVER RAINSCREEN. OVER 1� W !/\\!iii�!/����i���\!/�\!/�/�\!/�\!/.'� bila � Y2" 4' CONCRETE SLAB. :\�i����li�\!i�\//�\!i�\!i�\!i�\Q��� � W/MIN. 2%2" EMBEDMENT BLDG. WRAP.OVER Y2"CDX PLYWD. ON 2"x 6" 1� GYPSUM BOARD FOR INTERIOR TYP. i�Q�!/?~~W/</</</</N STUD @ 16"O.C. W/R21 BATT INSULATION i . EXISTING FOUNDATION WALL TYPICAL A - A DETAIL . - COVERED PORCH TYP. Scale:Y2"= 1' o" t LEDGER BOARD TYP. y2"GYPSUM WALLBOARD TYP. FOR INTERIOR WALLS 6" SHIPLAP SIDING OVER RAINSCREEN. OVER r32 x 10 FLOOR JOIST BLDG.WRAP. OVER/ CDX PLYWD.ON 2"x 6" HARDWOOD FLOOR I— M3Y8"x 9" GLULAM BEAM STUD C4) 16"O.C.W/R21 BATT INSULATIONN/4" PLYWOOD SHEATHING LLI i 2"x 10"CONT. RIM JOIST TYP. W � R-38 BATT INSULATION TYP. : I- O 2"x 6" P.T. SILL PLATE 4"x 4" POST l'�, ♦♦ ♦` ♦♦ ♦♦ ( < FINISH GRADE II. ♦♦ II •ii41I •♦♦ II M 11' M SII 't 0 I I 4" DIA PERF. DRAIN PIPE ,Zo 2"x 10" FLOOR JOIST @ 16"O.C. .006 BLACK VAPOR BARRIER I I Y2 PLYWD. SPLICES (3)8d INTO BEAM& \ r ��i.'...'' Y2" DIA. x 12"ANCHOR BOLT Z • • I (3) 8d INTO POST ; 4-', /)'' !,�!�S ;4 \� W/7" EMBED © 6'O.C. TYP. Z9 PERMIT SET 24 x 24"x 12" CONCRETE PAD ;..4 . - i• '• �.;,a � ,�� o0 jai';i�` I', .006 BLACK VAPOR BARRIER { UNDISTURBED SOIL �•� >;;AV,',' iA _gyp - '.' 4i. •:•1;,‘- k, ,,,,441," ' REVISIONS: /�/�/' /�/�/� TOP FILL SOIL &,8 \ #4 VERT. @ 48 O.C. TYP. 1v i / // // // // // // 4,/' ��L \ \6'/!/ems/.r /r�/.rY/!Y/.rl�/X/T�/rY/* azt CHECK SHEET \\\ \ \ \ \\\\\\\\\\\\\/\ \\\\\\\\\\ UNDISTURBED SOILS 1'-4"., \#4 TOP AND BOTTOM TYP. d \i\\,\\,\\,\\,\\r\\r\\,\\,\\,\\,\\,\\,\\r\\,\ "2 � Y. /45 ���'�1`", .44 \ DATE: 03/19/2013 . L POST FOOTING AND BEAM TYP. TYPICAL B - B DETAIL S - 3 Scale: /4"= 1'-0" Scale:%"= 1'-0" SCALE: VARIES r G 1 -1FD ,' -.r 1' - .r ELECT. AND MECH. SYMBOL LEGEND 0 Z J W >a 0 C7O W z 6 8 ZzLr, t O 120V DUPLEX OUTLEX O o co N • W 2 Dov I— - W m0Ei {0- CEILING MOUNTED FIXTURE z~ `'' a w � �W ---� E-' \ a BEDROOM \\ SD SMOKE DETECTOR 13'x 10' \ I SD _O`_ LIGHT/FAN UNIT I L L Q 120V DUPLEX OUTLET(GROUND FAULT INDICATOR) GFCI CL lDA 1 EXISTING Q �\\ �` TELEPHONE OUTLET -�I J moi I 3 TYPICAL WALL THREE WAY SWITCH U '- I I I- /67) J SINGLE POLE SWITCH w IDJ W r n TIVI OUTLET XIV IGENERAL MECHANICAL AND ELECTRICAL NOTES I- CO �� �' 1. LOCATIONS OF DEVICES AND FIXTURES SHOWN ON THE DRAWINGS ARE APPROXIMATE.THE CONTRACTOR N LJJ N. , ___ �/- Ef3 IS TO INSTALL ALL DEVICES AND FIXTURES IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. i THE CONTRACTOR IS TO PROVIDE THE OWNER AND ARCHITECT A DIAGRAM SHOWING THE REVISED W • r LOCATIONS OF ALL FIXTURES AND DEVICES PRIOR TO COMMENCEMENT OF INSTALLATION FOR REVIEW. w CC O \ ti \I 2.ALL EXTERIOR OUTLETS AND OUTLETS IN BATHROOMS AND KITCHENS AREA TO BE GFI PROTECTED. CC LIVING ROOM -.// 3. ALL EXTERIOR OUTLETS TO BE IN WEATHERPROOF BOXES. _ 16'x8' <\\ � 4. ALL DISHWASHER, REFRIGERATOR, HOT WATER HEATER AND HEATER CIRCUITS TO BE DEDICATED. 1 I 5. ALL DETECTORS TO BE HARD WIRED AND TO HAVE AN AUDIBLE SIGNAL < / PERMIT SET 6. THE FOLLOWING MOUNTING HEIGHTS WILL BE USED THROUGHOUT THIS PROJECT: \ Si_ SWITCHES 48"ABOVE FINISH FLOOR REVISIONS: 1 ELECTRICAL OUTLETS 18"ABOVE FINISH FLOOR TELEPHONE JACKS 44" IN KITCHEN CHECK SHEET �� 18"ABOVE FINISH FLOOR • ������� IV'��a ������\\\���.._ - `V ® ® CABLE TV JACKS 18"ABOVE FINISH FLOOR DATE: 03/19/2013 �� CIRCUIT BREAKER PANEL TOP OF PANEL @ 72"ABOVE FINISH FLOOR DOOR CHIME 48"ABOVEFLOOR ELECTRICAL PLAN ELECTRICAL METER BUTTON PER UTIILITYINISH REGULATIONS A - 6 Scale:Y4" = 1'-0" SCALE: 1/4"=1'-0" J