Loading...
Plans CE 2 6 2013IVEI CITY OFTIGARI) BUILDING DIVISION PROJECT INFORMATION OWN ER MEATH RESIDENCE CONTRACTOR ADVANCED ENERGY SERVICES 12445 SW BELL COURT 14755 SE 82ND DRIVE TIGARD,OR 97223 CLACKAMAS,OR 97215 MAIN:503-635.0117 CONTACT:JORDAN WEISMAN BUILDING SINGLE FAMILY RESIDENTIAL PHONE:503-407-6820 DATA i ROOF SPECS ASPHALT COMPOSITE SHINGLE ROOF(SINGLE LAYER) % W/2X4 TRUSSES DOUGLAS FIR#2 Q 24'O.C. ✓h APPLICABLE 2010 OREGON SOLAR INSTALLATION TILT:18 DEGREES III COD ES SPECIALTY CODE AZIMUTH:260 DEGREES ROOF AREA(PLAN VIEW)- 2,025 SF ARRAY AREA= 185 SF. ARRAY IS<25%OF ROOF AREA SYSTEM SOLARWORLD255W MONO 10 X 255W-2.295kW MODULE SOLARWORLD SUNMODULE 255W MONO (10 MODULES) SPECS MNNMET6t r.:' (10)ENPHASE M215 INVERTERS, (L)66°X(W)39,5"X(H)1:34' WEIGHT:47.6"LBS MAIN PANEL „. 1 INVERTER AT EACH MODULE COMBINED WEIGHT OF MODULES AND RACKING IS< AWAY 4.5PSF. PROJECT NOTESD „ ... _ ... .. .... _ ,. .. . 1. 303.2-PV SYSTEMS AND SUPPORTING STRUCTURE 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED gn . ,• SHALL COMPLY WITH REQUIREMENTS OF OSSC WOOD CONSTRUCTION WITH 2X4 TRUSSES AT 24"0,C, • ill CHAPTER 6 OR THE ORSC AS APPLICABLE. MAX.EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS 2. 303.3-ALL PV MODULES TO BE UL 1703 LISTED. IN TABLE 305.4.1. r. r 3. 303.5-PV SYSTEM SHALL HAVE A FIRE 8. 304,9.5-DISCONNECTS,J-BOXES,COMBINER BOXES OR r: r "' CLASSIFICATION THAT IS EQUAL TO OR GREATER GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED i • THAN THE ROOF ASSEMBLY REQUIRED BY OSSC PATHWAY OR CUTOUT, i. SECTION 1505.1. 9, ROOF MATERIAL IS ASPHALT COMPOSITE SHINGLE. i 4, 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE 10. PER 305.4 ITEM 3:TOTAL SYSTEM WEIGHT SHALL NOT (,: r RATED FOR THEIR USE. EXCEED 4,5 PSF.PV MODULES AND RACKING SHALL BE �-..: 5. 303.4.304,8-PV LAYOUT SHALL NOT RESTRICT DIRECTLY ATTACHED TO ROOF FRAMING AS SHOWN IN EGRESS, LIGHT,VENTILATION,OR ROOF DRAINAGE CONNECTION DETAIL#2.ATTACHMENT SPACING WILL Area of Work REQUIREMENTS. BE 48"O.C.MAX,AND WHEN ATTACHMENT LOCATED PV array • 6. 304.9.1 GENERAL PATHWAY REQUIREMENTS- WITHIN 3'OF ROOF EDGE,HIP,EAVE,RIDGE SHALL BE EXCEPTION 1:ON STRUCTURES WITH A PV ARRAY 24"O.C. MAX. AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF 11. MAX MODULE HEIGHT< 12"OFF ROOF SURFACE. WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN 12. SECTION 304.7-MECHANICAL EQUIPMENT INTERSECTING ADJACENT ROOF AND WHERE NO CLEARANCES: NOT APPLICABLE,THERE IS NO SECTION IS LARGER THAN 150 FEET MEASURED IN MECHANICAL EQUIPMENT WITHIN OR ADJACENT TO LENGTH OR WIDTH. AREA OF WORK. EXCEPTION 1A: WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A MINIMUM OF 12" UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. NORTH ADVANCED ENERGY SERVICES DATE: FEBRUARY 18, 2013 PROJECT #: AES MEATH O 1. SITE PLAN Scale: 1" - 30'-0" rimiiimimmdimisiii 14755 SE 82ND DRIVE 0' 15' 30' 60' CLACKAMAS, OR 97015 MEATH RESIDENCE 12445 SW BELL COURT 503-635-0117 TIGARD,OR 97223 CCB# 180882 CITY OF TIGARDDWG. 1 OF 3 Approved ` [�01� Conditionally Approved [ 1 Approved plans See Letter to:Follow [ 1 shall be on job site Attached Permit Number: ._?.i-6447i Add -ss: -y OFFICE COPY By: reA Date: 2- 4 , (e/d'a 3 l /f3o?/L,2 r I 2X4!ROOFTIUSS (�24j"O.C." P SOLAR 12 ARRAY �- _ ! -- -- -- 77;7 -7 -- : -- E)KISTING ROOF RIDGE - ;,„,,,,, „j, , , ',, .! I•,. t t 1 t 1 rMCIff,Th i S'!A1? EE SPACED F:C! t'. iES iEATE i" ":� ;:i•. i€� OF CEN NEER [ 4-:-,--,,,,,--,, f QA RNr u'r: 'r is °d tE1 ARRd0.Y i3! LOCATED W T I:V F 1 O A flQO yp :I /�y0CiAli..P4P tAvE C)Fi iSlt.�t3E, N ,O) i % '1� '� 1 4, '.V3ISC 38 ..I 3 its\ BUN EYE - READING i s i ! 41 I :� T. -,-,,:! -,:l!!...;.''':,'-',',-zI 4 2 ': I i iATTACHMENT CONNECTION ih RAILS,TYA TO ROOK i i TRI�5S,TYP; 1 L Ari Of IWork SECTION,TYP. N ED1. ENLARGED ROOF PLAN Scale: 1/4" ■ 1'-0" ADVANCED ENERGY SERVICES DATE: FEBRUARY 18, 2013 PROJECT #: AES MEATH 14755 SE 82ND DRIVE CLACKAMAS, OR 97015 MEATH RESIDENCE 12445 SW BELL COURT 503.635.0117 rIGARD,OR 17223 CCB# 180882 DWG. 2 O F 3 SOLAR COLLECTOR MODULE MODULE(4.5 PSF,MAX.) DIMENSION VARIES 1 4s '.a +st.tri 4 I y 1 MODULE DIMENSION s4 4:$tt.+ 10'MAX '`" SECTION A I ; A . .:4%. 1 14443N, .F4 SECTION A 'p*v 4 ;.,'ys 1t CONNECT SOLAR MODULE TO I .10:4s- s+a-. -.a *. .1;. I RAILS WITH I CONNECTOR * 1 I FOR EACH 8.SQ FT.OR ' '*.A � LESS OF MODULE SURFACE � '• +'0�#_.. �1 .co ;h CORROSION RESISITANT I 1 I METAL RAIL ANCHOR I '� R TO ALTERNATE ROOF %I I FRAMING 48"MAX.ON i..'4 CENTER PER SECTION A-A II .'+ �?, . n w*. t:Iii TYPICAL.PROVIDER 1 � '. MINIMUM OF 2 RAILS I I I NEW SOLAR MODULE PER MODULE ARRAY AND ATTACHMENT SYSTEM TO EXISTING I 1 ROOF TRUSSES G ROOF FRAMIN �"� -moi —4----i--0 48"MAX ON CENTER I 1 2. CONNECTION DETAIL Scale: NTS 11111166. EXISTING 2X4 COLLECTOR MODULE TRUSSES 4B 24'O.C.,TYP, MIN,2 X 4 RAFTER OR TRUSS CONTINUOUS SUPPORT CHORD cD 2'MAX,ON CENTER RAIL AND CONNECTION POST BY RAIL MANUFACTURER 1. SECTION SUNMODO EZ ROOF MOUNT AND FLASHING Scale: NTS WITH 3"STAINLESS LAG B TST AND L FEET .IINSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 3. CONNECTION DETAIL ADVANCED ENERGY SERVICES DATE: FEBRUARY 18, 2013 PROJECT #: AES MEATH Scale: NTS 14755 SE 82ND DRIVE CLACKAMAS, OR 97015 MEATH RESIDENCE 12445 SW OURT 503.635.0117 TIGARD ORE 97223 CCB# 180882 DWG. 3 OF 3 ' ''-, EQUIPMENT SCHEDULE/NOTES: NEC PV LABELING REQUIREMENTS (1)PV ARRAY,8 SOLARWORLD 255W MODULES 2.04 KW SOLAR PV SYSTEM (2)EACH PANEL CONNECTED TO ONE M215 ENPHASE MICRO • AC DISCONNECECTS&INVERTER(690.54): INVERTER.8 INVERTERS MAKE UP ONE BRANCH CIRCUIT. _ ' (3)6 AWG BARE COPPER EQUIPMENT GROUNDING CONDUCTOR M215 OUTPUT CIRCUIT WIRES. PV Array-8, 255-Watt S01arworld PV 'a s SOURCES:SOLAR SYSTEM AND UTWARNING:DISCONNECT ISILITY GRID.TWOED FROM (4)NEMA 3RANDSJUNCTION OTRANSITION WIRE FROM ENPHASE ENGAGE CABLETO THWN-2. MAXIMUM AC VOLTAGE 240 Vac (5)UTILITY GRADE METER TO MEASURE PV OUTPUT . . MAXIMUM AC CURRENT 0.9 Aac/inverter (6)GRID INTERCONNECTION BY 15ATW0 POLE BREAKER (1) (7)200A MAIN SERVICE PANEL WITH 200A MAIN BREAKER * - . -Iiiiii M (8)GROUNDING ELECTRODE CONDUCTOR CONNECTED TO AC CIRCUIT BREAKER(690.64) EXISTING BUILDING GROUNDING ELECTRODE. WARNING:CIRCUIT BREAKER IS ENERGIZED FROM NOTES: (2) -THE SUM OF THE RATINGS OF BREAKERS FEEDING ANY PANEL TWO SOURCES-SOLAR SYSTEM AND UTILITY GRID. MUST NOT EXCEED 120%OF THE RATING OF THE PANEL BUS BARS (NEC)690.64) MAIN SERVICE PANEL No 0 // 10 awg USE-2/RHW-2 4°" AC POINT OF CONNECTION \3J Sunlight Resistant Wire plus SOLAR ELECTRIC SYSTEM One#6 AWG Bare Copper Equipment Ground AC OUTPUT CURRENT:7.2A NOMINAL AC VOLTAGE:240V AC Voltage Drop Calculation ` 1.Intemal Voltage drop within cabling:8 micro inverters=.19% WARNING 2.Voltage drop from branch circuit to dedicated OCPD:N/A INVERTER OUTPUT CONNECTION 3.Voltage drop from OCPD to Main Service Panel DO NOT RELOCATE THIS OVERCURRENT DEVICE %Vdrop=(0.9A*8)*(2*30ft) (4) Junction Box to Transition wire ` =(432*(.00124ohms/ft))/240V THIS PANEL IS FED BY TWO SOURCES OF POWER =0.0022*100 1 "' 1-UTILITY 2-PV INVERTER =0.22%AC Voltage Drop Roof Top TOTAL AC VOLTAGE DROP:0.19%+0.22%=0.41% ti Ground METER CUSTOMER OWNED SOLAR GENERATOR OUTPUT Approximate distance from PROJECT 12445 SW BELL CT. roof top array to Main Electric Panel is 30 feet. IPTIGARD, OR 97223 2.04 KW SOLAR PV SYSTEM 3/4"EMT outdoors with . two #10 awg 2OOA Main Panel Solar Contractor THWN-2THWN-2 conductors rn #I a#10awg, 3/4"EMT from meter Equipment Neutral,and#6owg Meter Advanced Energy Equipment GND conductor to Main Electric Panel. 120/240 Volt, from array AC Disco to output meter Distance less than 10'. three-wire,single-phase r located next to main service panel. Services PV CD (7) Output Meter 200A Main Breaker TITLE: Single Line Diagram,Grid Tied Solar PV System I-----,1 e# 4 ]t utility (8) / DATE: 2/6/13 DRAWN BY: Jordan Weisman -I PROJECT/Customer Name: (5i Vi/ - oDrawing#:0001 l J 15ATwo Role� ; f� Grounding MEATH .. Backfeed'Breaker ---J Electrode —REVISION HISTORY DATE NOTES REVISION:00 2/6/13 #6 bare copper t