Specifications (14) A(.s To1-OIL^ )c 2� j,„ • `c. (S-S- c LJ /e?t-d� RECEIVED 10/25/2012 9721168-Lock.xlsx NOV 272012 CITYOBTIGARD BUILDING DIVISION SoIarCit.y 3055 Clearvie,v Way, San Mateo, CA.94402 23861 'Ali LIT', t;, 2489; v ir,...lultt',$t�.,r,ai STRUCTURAL DESIGN CALCULATIONS by YOO JIN KIM, P.E. PROJECT: Lock Residence - Project # 9721168 8.4 kW Roof Mount Solar PV System 14155 SW 103rd Ave Tigard, OR. 97224 REPORT PREPARED FOR: SolarCity, Inc. 3055 Clearview Way San Mateo, CA. 94402 888-765-2489 cogs PROP ct+G N F' 1• 1. OWNER: 82285PE r- Lock, Richard D 14155 SW 103rd Ave v oRj=oNce Tigard, OR. 97224 �ti, 13,2°0 503-849-6935 i% I :Juivo.3.•l3 PROJECT DESIGNED BY: SolarCity, Inc. Digitally signed by Yoo Jin Kim Date:2012.10.25 10:42:34 3055 Clearview Way -07'00 San Mateo, CA. 94402 888-765-2489 10/25/2012 9721168-Lock.xlsx SolarCity 3055 Ciearvie;w way Sal Mateo.CA,94402. 8881 SUL (t( 'i 745 /469' sala':,tv.tiiri Calculations by: JS Reviewed by: YK Table of Contents 1 Wind Load Calculations for Partially/Fully Enclosed Structures 2 Solar PV System a Rack Dead Load Determination 3 Roof Dead Load Determination 4 Determination of 2009 IBC[ASCE)-051 Seismic Loads 5 Rafter/Beam Calculations 6 Appendix - Image from Google Earth showing Wind Exposure a Lat/Lon - Seismic Spectral Response data from USGS web site Design Criteria: Designed to 2010 OSISC a 2010 OSSC Dead Load=10.5 psf(All MPs) Roof Live Load=20 psf Basic Wind Speed=95 mph Exposure Category B Roof Snow Load=25 psf 10/25/2012 9721168-Lock.xlsx Wind 3 ASCE7-2005 C&C Partially/Fully Enclosed Structure Wind Design Input Variables Calculations and Values Required Variables Design Wind Pressures based upon: mean roof height,ft 13 ASCE 7-05 Chapter 6 Wind Loading Exposure Category(6.5.6.3) B Basic Wind Speed(Figure 6-1 or local data) 95 Equation 6.5.12.4.1: h<60 ft Comp.and Cladding Elements Importance Factor(1 for residential) 1 Wind Pressure P=qh*(G*Cp) Roof Shape Gable/Hip 6.5.10:Velocity Pressure Panel Tilt(degrees) 18.0 deg qh= 0.00256*Kz*Kzt*Kd*VA2*I Roof Zone 3 contiguous sq.feet of array 67 From Table 6-3: least width of the building 34 Kz= 0.70 From Figure 6-4: Kzt= 1.00 Local Topographical Features From Table 6-4: (choose"standard"or refer to pictures right,and below) Kd= 0.85 type of hill none From figure 6-1: Hill Height(h)(ft) V= 95 slope of hill(degrees) From table 6-1: horizontal distance from hilltop to house(x) I= 1 height from bottom of hill to mean roof height(z) From Velocity Pressure Equation: qh= 13.75 Design Wind Pressures From Figure 6-19A P(lbs.per sq.ft.)=qh*Cn*G Cn(down)= 0.34 Pd(downforce pressure)= 4.73 Cn(uplift)= -1.31 Pu(uplift pressure)= -18.02 From 6.5.8.1 G= 0.85 Max Tributary Area Max Uplift Force on a Single Standoff Individual Rows in Portrait Pmax(lbs.)=Amax*Pu+0.6*PL*COS0 Trina TSM-240PC Pmax= -177 Amax(sq.ft.)=0.5*L*X Factor of Safety=FI*D*NI/Pmax L(length of panel in ft. perpendicular to rail 5.41 Fastner Type:Hex Lag Screw(Per Plans) X(distance between standoffs in ft.) 4.00 Fastener Diameter:5/16"-2.5"Min Embed Y(distance between standoffs in ft.) 2.67 250 =Fl(pullout capacity of fastener(lbs/inch)) Amax= 10.83 2.5 =D(minimum fastener thread depth) 1 =NI(number of fasteners per standoff) 3.53 =Factor of Safety Dead Load Calculations DL(lbs/sq.ft.)=(Mm+Mh)/(L*W) Point Load Calculations L(length of Trina TSM-240PC modules) 5.41 PL(lbs)=Amax*DL W(width of Trina TSM-240PC modules) 3.09 PL= 33 Mm(weight of Trina TSM-240PC modules) 43.00 Mh(weight of hardware per module)= 7.20 DL= 3.01 I B (Version 1_8 10/25/2012 9721168-Lock.xlsx Flush DL 4 CALCULATION OF SOLAR PHOTOVOLTAIC ROOFTOP SYSTEM DEAD LOAD All MPs MODULE AND STAND-OFF CHARACTERISTICS Module Make& Model: Trina TSM-240PC Panel Configuration: Rows in Portrait Nmod= 35 Quantity of Trina TSM-240PC modules Lmod= 5.41 ft Length of one Trina TSM-240PC module Wmod = 3.09 ft Width of one Trina TSM-240PC module Amod = 16.71 sf Area of one Trina TSM-240PC module Wtmod = 43.00 lb Weight of one Trina TSM-240PC module DLmod = 2.57 psf Unit dead load of Trina TSM-240PC modules Solar Rail Make& Model: SolarCity Rail Solar Rail Configuration: X-X Solar rails running in X-X direction Wtrad= 0.68 plf Unit weight of aluminum solar rail, plf Stand-off Make& Model: SolarCity Yeti - 1 Lag Wtstandoff= 1.75 lb Unit weight per stand-off assembly PANEL AND RACK SYSTEM GEOMETRY 0= 18.0 deg Tilt of panel system from horizontal ()roof= 18.0 deg Slope of roof mounting surface hmin= 0.33 ft Least panel height above roof surface(vertical dimension) hmax= 0.33 ft Greatest panel height above roof surface(vertical dimension) h = 0.33 ft Mean panel system height above roof surface(vertical dimension) Lx-X= 21.61 ft Array length in X-X Direction SX-X= 4.00 ft Standoff spacing in X-X Direction Ns,X-X= 6 Number of standoffs in X-X Direction Ly_y= 27.07 ft Array length in Y-Y Direction(actual dimension at panel tilt 0) 25.74 ft Horizontal projection of array length in Y-Y Direction Sy_,= 2.67 ft Standoff spacing in Y-Y Direction Ns,y-y= 10 Number of standoffs in Y-Y Direction 10/25/2012 9721168-Lock.xlsx Flush DL 5 DETERMINATION OF SYSTEM DEAD LOAD FOR SEISMIC ANALYSIS COMPONENT AREAS, LENGTHS,AND QUANTITIES Asystem = 585 sf Gross area of solar PV system Amodules= 585 sf Net area of solar modules only Nraii= 10 Number of solar mounting rails Lraii= 216 ft Approximate total length of solar mounting rail Nstandoff= 60 Number of stand-off assemblies DEAD LOAD CALCULATION Length or Unit Component Component Quantity Weight Weight, lb Solar Modules 35 x 43.00 lb = 1505 Solar Rails 216 ft x 0.68 plf = 147 Stand-off Assemblies 60 x 1.75 lb = 105 Subtotal for Hardware= 252 lb Total System Seismic DL= 1757 lb Weight of Hardware per Solar Module= 7.20 lb Weight of Modules per square foot of PV System = 2.57 psf Weight of Hardware per square foot of PV System = 0.43 psf Total Seismic System Weight per square foot= 3.00 psf 10/25/2012 9721168-Lock.xlsx Roof DL 6 DETERMINATION OF DEAD AND LIVE LOADS: All MPs DEAD LOAD LIVE LOAD Element Materials Wt. (psf) IBC 1607.11.2 Roof: Comp Shingle 6.00 Lo= 20 psf Roofing Paper 0.50 Ao-;b= <=200 sf 1/2 in. Plywood or OSB 1.50 R1 = 1 2 x 6 @ 24 in. o.c. 1.15 (Rafter) R2= 1 Miscellaneous 1.35 L,= Lo* R1 *R2= 20 psf 10.50 Roof Pitch 4:12 1.051 18.0 deg Dead Load @ Roof Pitch = 11.04 10/25/2012 9721168-Lock.xlsx Seismic 7 SEISMIC DESIGN CALCULATIONS FOR SOLAR PV ROOF MOUNT SYSTEM per 2009 IBC Section 1613 and ASCE 7-05 Chapter 13 SEISMIC DEAD LOAD System Configuration: Flush Mount W,= 1757 lb See Dead Load Worksheet PROJECT SITE DATA Street Address: 14155 SW 103rd Ave Tigard, OR. 97224 Latitude and Longitude from Google Earth Latitude: 45.42 deg Longitude: -122.78 deg Soil Site Class : D Default assumption per IBC 1613.5.2 SEISMIC GROUND MOTION VALUES USGS Earthquake Ground Motion Parameter Calculator http://earthquake.usgs.gov/hazards/designmaps/ Fa = 1.129 site coefficient from USGS web site F„= 1.729 site coefficient from USGS web site Ss= 0.928*g Spectral response acceleration at short periods from USGS web site Si = 0.335*g Spectral response acceleration at periods of 1 second, USGS web site SMS= Fa*Ss (2009 IBC 16-37, ASCE 11.4-1) SMs= 1.048*g SMI - F„*Si (2009 IBC 16-38, ASCE 11.4-2) SMI = 0.579*g SDs =(2/3)*SMS (2009 IBC 16-39,ASCE 11.4-3) SDs= 0.698*g SDI = (2/3)*SMI (2009 IBC 16-40,ASCE 11.4-4) 5D1 = 0.386*g COMPONENT FACTORS FOR ASCE SECTION 13.3.1 ap= 1.0 component amplification factor, ASCE Table 13.6-1 Rp= 1.5 component response modification factor, ASCE Table 13.6-1 1p= 1.0 component importance factor, ASCE Section 13.1.3 10/25/2012 9721168-Lock.xlsx Seismic 8 SEISMIC DESIGN FORCE, PER ASCE SECTION 13.3.1 0.4apSDSWP(1 +2z/h) Horizontal seismic design force FPt _ (Rp/Ip) (ASCE Equation 13.3-1) where: z= 13.00 ft h = 13.00ft Fp1 = 0.559 Wp = 982 lb Governs Fp is not required to be taken as greater than Fp2= 1.6SDSIPW (ASCE Equation 13.3-2) Fp2= 1.12 Wp = 1963 Ib and Fp shall not be taken as less than Fp3= O.3SDSIpWp (ASCE Equation 13.3-3) Fps= 0.21 W, = 368 lb GOVERNING SEISMIC DESIGN FORCE Fp= 982 Ib ALTERATION DESIGN CHECK, PER 2009 IBC SECTION 3403.2.3.2: (Seismic base shear is directly proportional to building mass) Building Mass for Partial Building: Arearoof= 1150 sf DI-Roof= 11.04 psf Woof= 12697 lb Areao,9= 1150 sf DLcig= 7.99 psf Wo,g = 9183 lb LengthEXt.wau= 170 ft DLExtwa��= 12.20 psf WExt.wall= 8296 lb Lengthint.wall= 170 ft DLInt.wall= 6.40 psf WInt.waii= 4352 lb Plate height? 8 ft WRoof= 34528 lb (Existing) Wsystem= 1757 lb Wproposed= 36285 lb Percent Increase= 5.09% <=10% Therefore, okay Gil F 0 R T E MEMBER REPORT PV Design Check,Section A:MP1(Rafter with Sister) PASSED 2 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 24" OC imampamtOverall Sloped Length:15'2 3/8" + + o 0 12 n 3.91--- " ,r rr 2'2" 6 72 I El All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results Actual 0 Location Allowed Result LDF Load:Combination(Pattern) System:Roof Member Reaction(lbs) 637 @ 2'2" 6900(3.50") Passed(9%) -- 1.0 D+1.0 S(All Spans) Member Type:Joist Shear(lbs) 439 @ 2'9" 2277 Passed(19%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential Moment(Ft-lbs) 1384 @ 8'3 13/16" 1950 Passed(71%) 1.15 1.0 D+1.0 S(Alt Spans) Building Code:IBC Live Load DeFl.(in) 0.365 @ 8'2" 0.628 Passed(L/413) -- 1.0 D+1.0 S(Alt Spans) Design Methodology:ASD Total Load DeFl.(in) 0.585 @ 8'2 1/8" 0.837 Passed(L/258) -- 1.0 D+1.0 S(Alt Spans) Member Pitch:3.9/12 •Deflection criteria:LL(L/240)and TL(L/180). •Overhang deflection criteria:LL(21/240)and TL(21/180). • Bracing(Lu):All compression edges(top and bottom)must be braced at 15'9/16"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. •A 15%increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS 2005 methodology. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Snow Total Accessories 1-Beveled Plate-DF 3.50" 3.50" 1.50" 221 417 638 Blocking 2-Beveled Plate-DF 3.50" 3.50" 1.50" 176 304 480 Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Dead Snow Loads Location Spacing (0.90) (1.15) Comments 1-Uniform(PSF) 0 to 14'3 3/4" 24" 10.5 25.0 Roof Dead and Snow Load 2-Point(Ib) 6'2" N/A 33 - PV Load 3-Point(lb) 8'8" N/A 17 - PV Load 4-Point(lb) 10'10" N/A 21 - PV Load 5-Point(lb) 12'4" N/A 11 - PV Load Weyerhaeuser Notes Y /�� SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes 10/24/2012 3:33:31 I'M Jesus Santiago 9721168-Lock I ortc v4.0. Design Lnginc:V5.6.1.203 solarclty 9/71168-i ock.4te (650)653 5726 jsan5ago@solarcity-corn Page 1cf1 'aFORTE ' MEMBER REPORT PV Design Check, Section C:MP1A(Rafter with Sister) PASSED 2 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 24" OC Overall Sloped Length:12'11 13/16" + + o O 12 3.9T-- 11'11" 1 / 0 All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Roof Member Reaction(lbs) 482 @ 12' 6563(3.50") Passed(7%) -- 1.0 D+1.0 S(All Spans) Member Type:Joist Shear(lbs) 430 @ 11'5 3/4" 2277 Passed(19%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential Moment(Ft-lbs) 1406 @ 6'2 3/16" 1950 Passed(72%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC Live Load Deft.(in) 0.361 @ 6'1 1/4" 0.620 Passed(L/412) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD Total Load Def.(in) 0.584 @ 6'1 1/4" 0.827 Passed(1/255) -- 1.0 D+1.0 S(All Spans) Member Pitch:3.9/12 •Deflection criteria:LL(L/240)and TL(11180). • Bracing(Lu):All compression edges(top and bottom)must be braced at 12'10 1/16"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. •A 15%increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS 2005 methodology. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Snow Total Accessories 1-Beveled Plate-DF 3.50" 3.50" 1.50" 173 305 478 Blocking 2-Beveled Plate-DF 3.50" 3.50" 1.50" 177 305 482 Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Dead Snow Loads Location Spacing (0.90) (1.15) Comments 1-Uniform(PSF) 0 to 12'2 1/2" 24" 10.5 25.0 Roof Dead and Snow Load 2-Point(Ib) 3'10" N/A 33 - PV Load 3-Point(lb) 6'5" N/A 17 - PV Load 4-Point(Ib) 8'6" N/A 21 - PV Load 5-Point(Ib) 10' N/A 11 - PV Load /� Weyerhaeuser Notes (Ij)SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes 10/24/2012 3.37:23 PM esus Santiago 9721168-Lock I orte v4.0, Design Lngine:V5.6.1.203 solarcty 9/21168-1 ock.411e (650)653 5726 jsantiago@solarcity.corn Page 1 of 1 MEMBER REPORT PV Design Check,Section D:MP2(Rafter) PASSED F® RTE 1 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 24" OC iiiOverall Sloped Length:7'2 5/8" + + o O 12 u 343 .rrr n SI I- 2 2" ', 4'6" Q ( 0 All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. Design Results Actual®Location Allowed Result LDF Load:Combination(Pattern) System:Roof Member Reaction(lbs) 374 @ 2'2" 3413(3.50") Passed(11%) -- 1.0 D+1.0 S(All Spans) Member Type:Joist Shear(lbs) 176 @ 2'9 1/16" 1139 Passed(15%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential Moment(Ft-lbs) -169 @ 2'2" 975 Passed(17%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC Live Load Dell.(in) 0.018 @ 0 0.225 Passed -- 1.0 D+1.0 S(Alt Spans) Design Methodology:ASD (2L/999+) Member Pitch:3.43/12 Total Load Defl.(in) 0.017 @ 0 0.300 Passed -- 1.0 D+1.0 5(Alt Spans) (21/999+) •Deflection criteria:LL(1/240)and TL(L/180). •Overhang deflection criteria:LL(21/240)and TL(21/180). • Bracing(Lu):All compression edges(top and bottom)must be braced at 7'1"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. •A 15%increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS 2005 methodology. Bearing Length Loads to Supports(lbs) Supports Total Available Required Dead Snow Total Accessories 1-Beveled Plate-DF 3.50" 3.50" 1.50" 128 246 374 Blocking 2-Beveled Plate-DF 3.50" 3.50" 1.50" 52 108 160 Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Dead Snow Loads Location Spacing (0.90) (1.15) Comments 1-Uniform(PSF) 0 to 6'9 3/4" 24" 10.5 25.0 Roof Dead and Snow Load 2-Point(Ib) 3'2" N/A 21 - PV Load 3-Point(Ib) 4'9" N/A 11 - PV Load /� Weyerhaeuser Notes (Zj)SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Forte Software Operator 7-- Forte —Forte Software Operator Job Notes 10/24/2012 4:15:47 I'M Jesus Santiago 9721168-Lock I ode v4.0, Design Lnginc:V5.6.1.203 SolarCity 9/21168-1 ock.4(e (650)653 5726 jsantlago@solarcity.com I'age 1 of 1 10/25/2012 9721168-Lock.xlsx USGS 10 Conterminous 48 States 2005 ASCE 7 Standard Latitude=45.417606 Longitude=-122.783316 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B- Fa = 1.0 ,Fv= 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 0.928(Ss, Site Class B) 1.0 0.335(S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude=45.417606 Longitude= -122.783316 Spectral Response Accelerations SMs and SM1 SMs= FaxSsand SM1 = FvxS1 Site Class D- Fa = 1.129 ,Fv= 1.729 Period Sa (sec) (g) 0.2 1.047(SMs, Site Class D) 1.0 0.580 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude=45.417606 Longitude= -122.783316 Design Spectral Response Accelerations SDs and SD1 SDs=2/3 x SMs and SD1 =2/3 x SM1 Site Class D- Fa = 1.129 ,Fv= 1.729 Period Sa (sec) (g) 0.2 0.698(SDs, Site Class D) 1.0 0.387(SD1, Site Class D)