Loading...
Specifications } 1 /TM 7650 S. W.Beveland I TM RIPPEY Tigard,Oregon 9722 CONSULTING ENGINEERS Phone. (503)443-3900 Fax: (503)243;3700 STRUCTURAL CALCULATIONS PROJECT: 11501 SW PACIFIC HWY-RTUs �v 1 N �a Ltez, 0 LOCATION: 11501 SW PACIFIC HWY % l , TIGARD,OREGON 97223 GU b CLIENT: WILLAMETTE HVAC 'r6 t• 19, c?'-' KYLE DATE: AUGUST 26,2016 Eat 6 Jae/j, PROJECT NUMBER: 16239 PROJECT DESCRIPTION: THIS DESIGN PACKAGE INCLUDES SKETCHES AND CALCULATIONS FOR INSTALLATION OF(2)NEW ROOFTOP MECHANICAL UNITS(5-TON AND 6-TON). WEIGHT OF CURB AND SLEEPERS ARE TAKEN INTO ACCOUNT.SKETCHES PROVIDE ATTACHMENTS OF UNIT TO CURB AND CURB ON SLEEPERS TO EXISTING ROOF STRUCTURE. TABLE OF CONTENTS: ITEM SHEET NUMBER GENERAL NOTES Ni DETAIL SK1-SK3 CALCICflT 'OP TIGARD Ci-Ci0 REVIEWED FOR CODE COMPLIANCE Approved: THE ACTIVATION OF A DUCT OTC: 1 SMOKE DETECTOR SHALL Permit#: M�C�of —OO �� ACTIVATE A VISIBLE AND Address: !/so/ w PAF c l Y AUDIBLE SUPERVISORY Suite :'' SIGNAL AT A CONSTANTLY By: ,---*11147/1110 Date: 'i( ((, ATTENDED LOCATION Mir" OMSC 606.4.1 OFFICE COPY GENERAL STRUCTURAL NOTES CODE REQUIREMENTS: CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS AMENDED BY THE 2014 OREGON STRUCTURAL SPECIALTY CODE,REFERENCED HEREAFTER AS IBC. DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE IBC. IN ADDITION TO THE DEAD LOADS,THE FOLLOWING LOADS WERE USED FOR DESIGN: NEW 5-TON UNIT WEIGHT=569 LBS.(BRYANT 580J-06A) NEW 6-TON UNIT WEIGHT=652 LBS.(BRYANT 580J-07A) BASIC WIND SPEED(3-SEC GUST,ULTIMATE): 120 MPH WIND EXPOSURE:B SEISMIC IMPORTANCE FACTOR Ie: 1.0 SITE CLASS:D(ASSUMED) SDS=0.726 ap=2.5 Rp=6.0 EXISTING CONDITIONS: THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS,DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NO 111,Y THE ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS PRIOR TO THE START OF THE WORK. TEMPORARY CONDITIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. CARPENTRY: SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION,LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. UNLESS NOTED OTHERWISE ALL LUMBER SHALL BE 19%AT TIME OF FABRICATION AND DRIED TO A MAXIMUM OF 15%BEFORE INSTALLATION OF GYP.BOARD AND OF BRICK VENEER AND VERIFIED BY THE GENERAL CONTRACTOR.ALL NEW HEADERS SHALL BE D.F.142 UNLESS NOTED OTHERWISE ON THE PLANS. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY(OR ENGINEER APPROVED EQUAL)AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTHERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF ST7.F RECOMMENDED FOR MEMBER. ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX NAILS ALLOWED. FASTENERS AND ACCESSORIES IN CONTACT WITH PRESERVATIVE TREATED WOOD MUST BE HOT DIPPED GALVANIZED OR HAVE ZMAX COATING. MECHANICAL: THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF ELECTRICAL EQUIPMENT,MECHANICAL, PLUMBING,FIRE SPRINKLER,MACHINERY,AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE NOT CONFORMING TO SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIQNAL ASSOCIATION (SMACNA),OR SPECIFICALLY DETAILED ON THE MECHANICAL ENGINEER'S DRAWINGS,SHALL BE DESIGNED IN ACCORDANCE OF THESE GENERAL NOTES,BY AN ENGIN k. IsG)ST1 ED IN TIDE STATE OF OREGON,,AND SHALL BE SUBMITTED TO THE NGINE ,�R PRIOR TO FABRICATION. FL') inti �! t.. •t,fie I �� AL F II • 4C4FING SHAL BE BY OTHERS UNTESS NOTED OTHERWISE ON THE PLANS. By: VL Date: 76 0 SW F w..IP L ITTE HVAC chk By Date: St e 100JE Wit: •• . „A 11501 SW'PACIFIC HWY Job#:_16239>„ Ti:arrd on 9712 Phone: )44r- 0 C D,OR Sheet: N1 Of UNIT w2& E04E. AG/4 N uN r t GtJge W/ 1x/2 MEM6:AS. A I l?L i (A/0.6 ID St r effL p � I Ist�3 Arrn&li 51 Fee - 7'0 lloo r 5112-ucl ugh w/ srMvsoAo '146,' TIE , DiP• (u) PLAt4- A5. spowiJ. lam. fV 13.vICO A &ox. wi Oi(/2 P.T. hEM-File 02 CIMPSoN °q 35' CLtP, T•110, MEMBI`US. Cov,v eT Ar '----41"---- — •t I=1 -i ini toE caitikde S wif ' MP O1' .436' GurP5 AT ('i) COLA�fi` S P�oV IDE L1 w� P,?, ' I i i Q �' al-61 . ear1 'f2. 13L,k HEM FIt!' 2 1 I G,s/ r/2" fL,YfOP. ME(�PE UNp t i LQNf, ©e, Li YlZ jkAPARAS UNIT" curt(?. NAND I I M. IN �+S�� SPRN (W0� s(s M • A-T EA-t ( FMS 14 L —c-;1--,- * _' 6imPscio `LIJs4t't' EXIST1 N4 2o" TTI 144N4E4y Dip. to t s rs @ V- 8" ole (2) P1.-14-;6 ‘ y (eoNTIl-ALrD yreIpi , SK3 e-' N NFw 2TU A-mi) GUKB L17TA;�h SLEEP Y� 70 F3`/ o 1-i 6( ' , /17TA{Lt t 2ooP S'MEATm 1104 w/ 7o 60P6 = 1151 3 SI1.1.P6c IJ 'A 35' ' LIP Li)/ PAX o.(3849 x Ye PAN FIFA© UtitpflvF lAi000 SGrt.GwS i TVP. (6) PL CE-s ci CUIZIS fTT (_ItMENr Pt, d�1/�I 5c6G6; 3lg =(! M ECHANICAL UNIT Ems. SPACES I C TH WATS BY OTHERS T'YP Igo GA. CLIPS I.U! (8) *IC 'MIS SCREWS PER 16 GA. CLI .. CLIP, (4) CLIPS REQ1D. iM SEE PLAN Yl W POR (J. CLIP LOCATION loop BLOCKING CLIA' RE C11111 LOCATION 1 . TOTAL FLASWIN0 ANO INSULATION N.-- MEOW UNIT NOT SHOUL*# FOR CLARITY' OUTL NE tlIATERPROOPING By OT 1 1 S PLAN vI EUJ SLEEPER PER PLAN PROVIDE#10 SCREWS @ 1'-0" :... 0/C AND AT 6"FROM ENDS OF CURB.MINIMUM 2" EXISTING ROOF EMBED.INTO WOOD. SHEATHING (4)MIN.PER SIDE. PROVIDE 2x8 D.F. #2 " SIMPSON TIE EACH SIDE OF WEB AT � • ! + � PER PLAN EACHTIEW/ (6)TOTAL 16d'N'AILS, (3)NAILS TO + — • EACH 2x8. INSTALL < EXISTING JOIST TIGHT TO TOP CHORD. PER PLAN SECTION AT CURB SK3 N T.S 11\iIKTM RIPPEYr' is BY VL DATE CONSULTINGENGIWII.,LAMET'1'h HVAC CHIC BY DATE 7650 S.W.Beveland St,Suite 100 11501 SW PACIFIC HWY _ JOB NO 16239 Tigard,Oregon 97223 TIGARD, OR Phone(503)443-3900 SHEET SK3 of , 04,14 Weems a: 4 �->aVITLf loAD AA/Ri,y1 5 58®S-06A : 5-6g F)05 -11�vijoin . ' Zo" `TSL 3Si C) 32�'Df coria tic 4 (aS w,a, , 760# wGi65l,v,� 3.11 �I1 ± = /,215-- p“ z 4 K.6 5 6194 _ 29 -8" > kG+44( -p ZS,/' t i from TR US JQI ST cfT1G aC -A✓ Sim pie 53 DS01, ', 6524.' I �i , fi �PR� , rn�k �4� �J J 16 I 0+ 5 GL44 =,- .1i5- (4.55(44/1 .1, 823 � r 5(e g - 56 A Mgltow _ 106 ,it ligl 08xl1/49en = 11. 1/43 ii.- 1i ' ) � Val/0c., - JOG 2 /000 1.S' / k T 31j � (2q ,s, •• Fo✓ 5feoa - ©6A.: -/ I, _ ifs ` l3 = 2og, pll s,( b 1 1 (' ,L I. L> see s ?k 194 a �ee cuv(o �i)iehs eNS ON p, C3- A II 1 ,i- 5 - 25- p 13' wp 1t (34112) c, 21 33 el Ws L 2c (32" //1) m 66- Gpi M = l 1. 692 1G-Ti- -> y, q to we 5.0 7a, 011- _j_ St, P6,0 5E6, 114114,w ' MI 'FT') V= 1 s 7,•' !i- 'U,Ati w - 1.537 0/ (rev 1 6e1� Se,4i'av► 3403,3 , 11, G)tte�/4�i -c Key'41. o Foy 5305- D��) ' /453(404e (2) wtiidolie joys-s • , AP 19 _ S23 /3 = 2 ft .--t ait !i3 or( la 4 (2) c9be1 D+s ©;Sts '141L-E I/6 of (.0441 k _ w. - Z f. 33 19 ; 1 SIS - 66. 6,1 p1e 21 5' 6' M = IL IY3 11,11. MAIi. ° mil-13 1t.k (2(4- EWfgG41-e- v = 1.S2? > VR(10,.,) /:53ik (3,3 % d IlGvt4/, a. <S%) dl.... 1M KT I RIPPEY BY V L DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St,Suite 100 JOB NO ió 2 3 J Tigard,Oregon 97223 Phone(503)443-3900 SHEET C 1 OF___. F (. .0A d 4 S • Esf wiai le 147, o goof-4'6/1j 2 eS Ghee Xy hei„,1 !.S Pst Mak , log4 /(2 siA e 3,5'} l (- 1,0 I' ( (0 4,3 p I ( etirZi (dyer sH �T sior wee g � ( H/ 5� 2 a•4 M Z. 66 14,In 1.275 pS/ - 860 psr ( 1,1c) (1,3)' = /.270 '05; (Nen —Fi✓ /LiisG, 0.5 e5/ � Cr Itz) z la, 3?-5 es s llaw = 6 /2 (.1/(6) //aao = q, 02 k.111 M � S4 j rl p S U, 1'0 . ( 16 //2) 2 = 2.06 LOS 44/ A4,116/ G41aer1`j �' r18019 0v-- TM RiPPEY BY - DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St,Suite 100 JOB NO r6 Zai Tigard,Oregon 97223 Phone(503)443-3900 SHEET C 2 of R62�A '1201prtetl1639 W1iiiRteHVAC 1501WEcFaar�c;H RTU,0-kvcc.-ryACLCst623e6 G@n@raeatInaIySJS ENRCALCs1019&3-20168ui1d6:1667, Vr6151231 : . tensee fm rppey o suitingengineers: :Lic.#.,KW060026 Description: Joist Analysis(580J-06A)(new) GeI a(Bearn Properties:: Elastic Modulus 29,000.0 ksi Span#1 Span Length = 28.90 ft Area= 10.0 in^2 Moment of Inertia = 100.0 in^4 o(o.47) kk0.02933,;(0.06667)1 2 Span=28.90 8 2 Appil,Pd;Loads Service loads entered.Load Factors will be applied for calculations. Uniform Load: D=0.02933, S=0.06667 kilt, Tributary Width=1.0 ft Point Load: D=0.2470 k @ 13.0 ft,(RTU(6A)) DESIGN;SUMMARY Maximum Bending= 11.692 k-ft Maximum Shear= 1.523 k Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span 13.294ft Location of maximum on span 0.000 ft Span#where maximum occurs Span#1 Span#where maximum occurs Span#1 Maximum Deflection Max Downward Transient Deflection 0.364 in 953 Max Upward Transient Deflection 0.000 in 0 - Max Downward Total Deflection 0.597 in 580 Max Upward Total Deflection 0.000 in 0 Maximum Forces.&Stresses for'Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma-Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/0mega Overall MAXimum Envelope Dsgn.L= 28.90 ft 1 11.69 11.69 1.52 +D+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+L+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+Lr+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+S+H Dsgn.L= 28.90 ft 1 11.69 11.69 1.52 +D+0.750Lr+0.750L+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+0.750L+0.750S+H Dsgn.L= 28.90 ft 1 9.97 9.97 1.28 +D+0.60W+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+0.70E+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+0.750Lr+0.750L+0.450W+H Dsgn.L= 28.90 ft 1 4.80 4.80 0.56 +D+0.750L+0.750S+0.450W+H Dsgn.L= 28.90 ft 1 9.97 9.97 1.28 +D+0.750L+0.750S+0.5250E+H Dsgn.L= 28.90 ft 1 9.97 9.97 1.28 +0.60D+0.60W+0.60H 0.34 Dsgn.L= 28.90 ft 1 2.88 2.88 +0.60D+0.70E+0.60H Dsgn.L= 28.90 ft 1 2.88 2.88 0.34 Overall',Maximum Deflections Load Combination Span Max."-*Defl Location in Span Load Combination Max."+"Deft Location in Span +D+S+H 1 0.5973 14.450 0.0000 0.000 63 General �ea Analysis pi 20tf}prolectstJ623$ N4NametteHVAG 11501 SW#?acifiroMv�y RTU s1STRUCTURALICALCSt16239eo6 Lw ##` KW 06002662 . ENERCALC,INC:1963 2016,Bmki 616 6 ZVer6.15.12;31..' _ . Lrc�nsee:tm rippey:cnnsuit�ng engmesr�.. Description: Joist Analysis(580J-06A)(new) Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.523 1.498 Overall MINimum 0.336 0.321 +D+H 0.560 0.535 +D+L+H 0.560 0.535 +D+Lr+H 0.560 0.535 +D+S+H 1.523 1.498 +D+0.750Lr+0.750L+H 0.560 0.535 +D+0.750L+0.7505+H 1.282 1.257 +D+0.60W+H 0.560 0.535 +D+0.70E+H 0.560 0.535 +D+0.750Lr+0.750L+0.450W+H 0.560 0.535 +D+0.750L+0.7505+0.450W+H 1.282 1.257 +D+0.750L+0.7505+0.5250E+H 1.282 1.257 +0.60D+0.60W+0.60H 0,336 0.321 +0.60D+0.70E+0.60H 0.336 0.321 D Only 0.560 0.535 Lr Only L Only S Only 0.963 0.963 W Only E Only H Only Cl' 1 P 12016 P[oteds\1623 W19amette HVAC 11501 SW Pacippif RTU�sFSTRUCTURQt.1CALCSt16239 eo6 @(11e..' � �E;c�,:„. AnalySi EtJERCALC INC 19&32016 emk161667 Ve0,1 1231 Lc ## KW0600266Z Licensee;Unrippeyconsulting.engineers.i Description: Joist Analysis(580J-07A)(new) General:Beam Properties:: Elastic Modulus 29,000.0 ksi Span#1 Span Length = 28.90 ft Area= 10.0 inA2 Moment of inertia = 100.0 in^4 S(0275) D(0,02933�5(0.06687) * 2 Span=28.90 4 2 AppliedLoads Service loads entered.Load Factors will be applied for calculations. Uniform Load: D=0.02933, S=0.06667 k/ft, Tributary Width=1.0 ft Point Load: D=0.2750 k @ 21.0 ft,(RTU(7A)) filDea0k$00.10ARYINIMIllitiiiiiiINERMINiiiiii Maximum Bending= 11.138 k-ft Maximum Shear= 1.587 k Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span 15.173ft Location of maximum on span 28.900 ft Span#where maximum occurs Span#1 Span#where maximum occurs Span#1 Maximum Deflection Max Downward Transient Deflection 0.364 in 953 Max Upward Transient Deflection 0.000 in 0 Max Downward Total Deflection 0.585 in 592 Max Upward Total Deflection 0,000 in 0 Maximum Forces&Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma-Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Overall MAXimum Envelope Dsgn.L= 28.90 ft 1 11.14 11.14 1.59 +D+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+L+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+Lr+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+S+H Dsgn.L= 28.90 ft 1 11.14 11,14 1.59 +D+0.750Lr+0.750L+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+0.750L+0.750S+H Dsgn.L= 28.90 ft 1 9.40 9.40 1.35 +D+0.60W+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+0.70E+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+0.750Lr+0.750L+0.450W+H Dsgn.L= 28.90 ft 1 4.24 4.24 0.62 +D+0.750L+0.750S+0.450W+H Dsgn.L= 28.90 ft 1 9.40 9.40 1.35 +D+0.750L+0.750S+0.5250E+H Dsgn.L= 28.90 ft 1 9.40 9.40 1.35 +0.60D+0.60W+0.60H Dsgn.L= 28.90 ft 1 2.55 2.55 0.37 +0.60D+0.70E+0.60H Dsgn.L= 28.90 ft 1 2.55 2.55 0.37 MOVet0111 Maximum Deflections. Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span +D+S+H 1 0.5851 14.739 0.0000 0.000 G5 C7rvCl0t'0) B �tl/1t1�11j/SIS P12016Pro1ectst16239 Wi9amotleHVAC-115018WRabflcM c;RTUstSTRUCTURAL%ALCS116239eo8 Et4EROALC I. 1983 2016;Butkt 6.16.6.7',Ver6.1812;31.. Lac # Ki1V 060026lit Licensee.Cm r►ppey consulting engineers Description: Joist Analysis(580J-07A)(new) Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.462 1.587 Overall MINimum 0.299 0.374 +D+H 0.499 0.624 +D+L+H 0.499 0.624 +D+Lr+H 0.499 0.624 +D+S+H 1.462 1.587 +D+0.750Lr+0.750L+H 0.499 0.624 +D+0.750L+0.7505+H 1.222 1,346 +D+0.60W+H 0.499 0.624 +D+0.70E+H 0.499 0.624 +D+0.750Lr+0.750L+0.450W+H 0.499 0.624 +D+0.750L+0.750S+0.450W+H 1.222 1.346 +D+0.750L+0.7505+0.5250E+H 1.222 1.346 +0.60D+0.60W+0.60H 0.299 0.374 +0.60D+0.70E+0.60H 0.299 0.374 D Only 0.499 0.624 Lr Only L Only S Only 0.963 0.963 W Only E Only H Only G6 LA AL tioilD Al /I1/1SIS • (,n,'+ PioienSians' Se(51,,,A4e,_'. b5 c 0.324 (v545) 5ia-e Cf4SS `0') I-, See t ac e cl 9/104 o(44 SSo i-06A : 1 evi5ll, 761_h ^ w X63 : v r. 120wipi, E)y. a lit d - 6/6.7s" Neljl,,d = 33.671' Fvbvh /-4444 6/.1 54 ea primioGti'S' 5'803 -03A1 5sba -06A . V = X35 wit/P (.116-°)//e6,13' = 311.1/`' T; 5504 61911c°e w1GI = 146,3-5" 5ZbZ-- 01-) U = 8$3 , won) I1e15t�4" - 41.11" T = 682# i 4ov6e. �4sn) Flo 5 cve w (5l ►eav, /6 44 l.5 peh . ivy� D,F. ) • Cc,I /19 Dir eo si obis 00041,41) 1-> GAPAe►TY' = 1. 6 (HO(-1-5-) --' /116 ° rtv 580.T o&el . ./4h = H't # 0 *fa 50/61,615 veei',I 82,3 tif/lf6At , 6,ns >(. ) VII'A ,1 . 113' 1 682 l'/y6 # - 19,6'1" _? ( ) kGag +- = 1611,1 25.2.5 =� Uni-1 -4 - GN✓6 Oje �i�lz t3ox (67) 4110 5e,tiem/5 Ago to SIOF or Cu tz 6. Vov1-Ae- 0j Stvvlss WCO /-0'' Q/c . 1 c4r4w41I 6,11 ( 10): n�i(i. k l0 54t� rf 5i col loo (1 0(1.5pepi•) . Ztta 221 /Zitoo = 2.8ct '> (3) Elt acarb - moo1 5IYGt.Lmv 5161 es00 A356l pS 44 5tie-ot✓ g13 41-/ ti 25 _ 2 o 2 =? (3) wtiti• > O5e (6) A35 G1 y 4M1 " F✓ 4M—SiQ,i, pvbwJe (ti) l .S Oo 41 (2) rev 3 L : 6324/2 3q1' use -- S(11p3oN '116 ' cerpe�i'J 9s--e 4— Oje L Y i y 3. TM RIPPEY BY V t DATE ---_. _---, �[ CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St,Suite 100 JOB NO 16 2 Tigard,Oregon 97223 Phone(503)443-3900 SHEET C OF Wind and Seismic Loads on Mechanical Unit 6T°P U0`)►"f Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based on the ASCE 7-10. H old down forces are calculated based on 0.6D + (0.6W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed:= 120mph Exposure:= "B" Vasd'= "no" (Is wind speed ASD?) Seismic Parameters SDS:_ .726 ap:= 2.5 Rp:= 6.0 IE:= 1.0 Building Dimensions Category:_ "II" Roof Elevation:= 24ft Building_Width:= 128ft Building Depth:= 3111 Mechanical Unit Dimensions Displacement:_ "Fan Unit" Weight:= 7401b UnitHeight:= 33.4in Width:= 46.75in Length:= 74.4in Curb:= 25.25in Curb Width:= 43in (Dimension for Calculating Overturning Uplift) SUMMARY(ALL VALUES ARE ASD) Method Used= "ASCE 7-10 Section 29.5.1" D=740 lb — WWindUpliftASD=487 lb Displacement= "Fan Unit" (From ACSE 29.5-3) EASD= 188 lb hseismic= 3.496ft WWindASD =7751h (From ACSE 29.5-2) X= 3.583 ft hWtnd= 2.444ft TWind'1'ota1ASD= 5501b Notes: lseismicASD=—39 lb 1.Positive sign convention shown.Negative values indicate opposite direction 2.X equals the width between attachment points for overturning ��� Wind and Seismic Loads on Mechanical Unit -3--TON UNI'( Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based • on the ASCE 7-10. Hold down forces are calculated based on 0.6D + (0.6W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed:= 120mph Exposure:= "B" Vasd'= "no" (Is wind speed ASD?) Seismic Parameters SDS:= .726 ap := 2.5 := 6.0 RP IE:= 1.0 Building Dimensions Category:= "II" Roof Elevation:= 24ft Building_Width:= 128ft Building Depth:= 60ft Mechanical Unit Dimensions Displacement:_ "Fan Unit" Weight:= 8231b UnitHeight:= 41.4in Width:= 46.75in • Length:= 74.4in Curb:= 25.25in Curb_Width:= 43in (Dimension for Calculating Overturning Uplift) - SUMMARY(ALL VALUES ARE ASD) Method Used= "ASCE 7-10 Section 29.5.1" D = 823 lb — WWindUpliftASD=4891b Displacement= "Fan Unit" 1 (From ACSE 29.5-3) EASD= 2091b hseismic=3.829ft fib WWindASD =883 lb (From ACSE 29.5-2) \ 1 hWind 2.77711 i X= 3.583 fl, = TWindTotalASD= 682 lb Notes: TseismicASD=—23 lb 1.Positive sign convention shown.Negative values Indicate opposite direction 2.X equals the width between attachment points for overturning /1Eirlk C /o V e c) y_ 7v SgzJ GAS HEAT/ELECTRIC COOLING b Y SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS o Heating&Cooling Systems Product Data T AF.GACYTM LIN E iii; ';;; \ y\- 'te-r ''''':::14171 %%i',';''... %�:� a 6�y Y Cam_ \ate!�Q 3 ''',13..:::-' ''' / .,,o,:,:,;,,, ,,..,i,:;,„,\?y��Efi- ,F . ...,,.t,l,,,,, ,,, ,,,,,„,:,,,,,:*,,,,4;,,,,, ,,,-,.,f,- ' '' ;',1;,';•.",:-.,-*41.;,414.,,,,,,,-,k,-**'''' C08515$` � �� - _ yr\� (Shown with optional Louvered Hail Guard) 111111 'T ' ! puron COMPLIA) FEATURES AND BENEFITS • Single cooling stage models • SEER up to 14.1. • EER's up to 12.0. •Up to 28%lighter than similar industry units.Lighter rooftops make easier replacement jobs. • Utility connections are the same because 3 5 ton units fit on existing Bryant rooftop curbs.This saves time and money on replacement jobs. • Standardized components and layout.Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units.This makes service,stocking parts,replacement,and troubleshooting easier. • Field convertible airflow.Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. • Standard Direct Drive - ECM indoor motor with optional belt drive system to meet nearly all applications. • Provisions for bottom or side condensate drain. •Capable of thru-the-base or thru-the-curb gas line routing. CO • Single-point gas/electrical connection. • Sloped,composite drain pan sheds water;and won't rust. • Standardized controls&control box layout.Standardized components&controls make stocking parts&service easier. •Tool-less filter access door. • Clean,large,easy to use control box. • Color-coded wiring. •Large,laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single,central terminal board for test and wiring connections. •Fast-access,handled,panels for easy access on normally accessed service panels. • "No-strip"screw system guides screws into the panel &captures them tightly without stripping the screw,the panel,or the unit. •Mechanical cooling(115°F to 40°F or 46°C to 4°C)standard on all models.Winter Start Kit allows cooling operation down to 25°F(-4°C)and MotorMaster to-20°F(-29°C). •High efficiency,gas heat with induced-draft flue exhaust design. • Induced draft motor ensures no flue gas can escape into the indoor air stream. • Bryant designed naturally draining heat exchanger,unlike positive pressure heat exchangers,do not need to be periodically,manually drained. This saves labor and maintenance expense. •2-in(51mm)disposable filters on all units. • Refrigerant filter-drier on each circuit. •Each circuit is protected with a high and low pressure switch. • Many factory-installed options ranging from air management economizers,2 position dampers,plus convenience outlets,disconnect switches and smoke detectors. • Standard(parts only)Warranty: 15 yr. Stainless steel, 10 yr. aluminized heat exchanger,5 yr.compressor, 1 yr. parts. •Factory-installed Perfect Humidity'° dehumidification system on all sizes, includes MotorMaster I controller. 3 MODEL NUMBER NOMENCLATURE Position: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Example: 5 8 2 J E 0 6 A 0 7 2 A 0 B 0 AA Unit Type Packaging and Control 582-Gas Heat RTU,Legacy Series A= Standard Packaging,electro mechanical controls that require W7212 EconoMi$er IV Model B= LTL Packaging,electro mechanical J - Puron®(R-410A)Refrigerant controls that require W7212 EconoMi$er IV C= Standard Packaging,electro mechanical controls that require W7220 EconoMi$er X Voltage F= LTL Packaging,electro mechanical E= 460-3-60 controls that require W7220 EconoMi$er X J = 208/230-1-60 P= 208/230-3-60 T= 575-3-60 Factory Installed Options OA =None NOTE:See the 582J 3 to 5 ton Price Pages Cooling Tons for a complete list of factory installed ci 04- 3 tons options. 1.0 05-4 tons 06- 5 tons Outdoor Air Options A= None Refrig.System/Gas Heat Options B= Temperature Economizer,Barometric Relief, A= Standard One Stage cooling models/Nat.Gas Heat Standard Leak(W7212 or W7220) B= Standard One Stage cooling models/Low NOx Heat E= Temperature Economizer,Barometric Relief, C= Standard One Stage cooling models/SS HX Heat Standard Leak w/CO2(W7212 or W7220) G= One-Stage cooling models/Alum Heat Exchanger H= Enthalpy Economizer,Barometric Relief, with Perfect Humidity TM Standard Leak(W7212 or W7220) H = One-Stage cooling models/Low NOx Heat L = Enthalpy Economizer,Barometric Relief, with Perfect Humidity Standard Leak w/CO2(W7212 or W7220) J = One-Stage cooling models/Stainless Steel Exchanger Q= Motorized 2 Position Damper with Perfect Humidity U= Temperature Economizer,Barometric Relief, Ultra Low Leak(W7220) Heat Level Input W= Enthalpy Economizer,Barometric Relief,Ultra Low Leak Standard/Stainless Steel (W7220) 072=72,000 115=115,000 Indoor Fan Options 15C=150,000 0 = Direct Drive ECM Low NOx 2 = Medium Static Option • 060=60,000 3 = High Static Option 090=90,000 120=120,000 Coil Options(RTPF)(Outdoor-Indoor-Hail Guard) A= Al/Cu-Al/Cu B= Precoat Al/Cu-Al/Cu Note:On single phase(-J)voltage code)models,the C= E-coat Al/Cu-Al/Cu following are not available as a factory installed option: D= E-coat Al/Cu-E-coat Al/Cu -Perfect Humidity E= Cu/Cu-Al/Cu -Coated Coils or Cu Fin Coils F= Cu/Cu-Cu/Cu Louvered Hail Guards M= Al/Cu-Al/Cu—Louvered Hail Guard -Economizer or 2 Position Damper N= Precoat Al/Cu-Al/Cu—Louvered Hail Guard -Powered 115 Volt Convenience Outlet P= E-coat Al/Cu-Al/Cu—Louvered Hail Guard Q= E-coat Al/Cu-E-coat Al/Cu—Louvered Hail Guard R= Cu/Cu-Al/Cu—Louvered Hail Guard S= Cu/Cu-Cu/Cu—Louvered Hail Guard C14337 4 Table 2-AHRI COOLING RATING TABLE NET NOM. TOTAL . UNIT COOLING CAPACITY COOLING POWER SEER EER STAGES (TONS) CAPACITY O (MBH) 582J*04 1 3 35.4 3.0 14.0 12.00 582J*05 1 4 47.5 4.0 14.0 12.00 582J"06 1 5 58.5 4.9 14.1 12.00 LEGEND NOTES: AHRI - Air Conditioning,Heating and Refrigeration 1. Rated in accordance with AHRI Standard 210/240. Institute Test Standard 2. Ratings are based on: ASHRAE - American Society of Heating,Refrigerating Cooling Standard:80°F(27°C) db, 67°F(19°C) wb indoor and Air Conditioning,Inc. air temp and 95°F(35°C)db outdoor air temp. EER - Energy Efficiency Ratio 3. All 582J units comply with ASHRAE 90.1 Energy Standard for SEER - Seasonal Energy Efficiency Ratio minimum SEER and EER requirements. 4. 582J units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes. csiC kjim I� II RADII CERTIFIED,., co in y Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the SHeli program For verification "�`1.1c of certification for individual 7/ products,go to \ 7 ;-, www.ahridirectory.org. COMPLIANT;, Table 3-HEATING RATING TABLE-NATURAL GAS&PROPANE AL/SS HEAT EXCHANGER THERMAL UNITS GAS HEAT TEMP RISE EFFICIENCY AFUE INPUT/OUTPUT INPUT/OUTPUT (DEG F) (%) (%) STAGE 1 (MBH) STAGE 2(MBH) LOW - 65/50 25-55 82.0% 81.0% 04 MED - 90/73 45-85 82.0% 81.5% HIGH - - - - - a co LOW - 65/50 20-55 82.0% 81.0% t a d 05 MED - 90/73 30-65 82.0% 81.2% c c HIGH - 130/105 45-80 82.0% 81.0% in LOW - 65/50 10-55 82.0% 81.0% 06 MED - 90/73 25-65 82.0% 81.2% HIGH - 130/105 35-80 82.0% 81.0% LOW - 72/56 25-55 82.0% N/A 04 MED 82/66 115/89 55-85 80.0% N/A HIGH - - - - - a tu LOW - 72/56 25-55 82.0% N/A a 05 MED - 115/90 35-65 81.0% N/A d t HIGH 120/96 150/117 50-80 80.0% N/A ~ LOW - 72/56 20-55 82.0% N/A 06 MED - 115/90 30-65 81.0% N/A HIGH 120/96 150/117 40-80 80.0% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m).For information on propane or altitudes above 2000 ft (610 m),see the Application Data section of this book.Accessory Propane/High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft(610m)must be derated by 4%for each 1000 ft(305 m)above sea level.In Canada, the input rating must be derated by 10%for altitudes of 2000 ft(610 m)to 4500 ft(1372 m)above sea level. 8 Table 6—MINIMUM -MAXIMUM AIRFLOW RATINGS-NATURAL GAS&PROPANE HEAT COOLING AL HX HEATING SS HX HEATING VOLTAGE UNIT LEVEL — MINIMUM MAXIMUM MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 900 1970 900 1970 582J*04 MED 900 1500 800 1520 800 1520 HIGH — — — — LOW 900 2470 900 2470 SINGLE 582J*05 MED 1200 2000 1050 2280 1050 2280 PHASE HIGH 1230 2190 1230 2190 LOW 900 3290 900 3290 582J*06 MED 1500 2500 1050 2730 1050 2730 HIGH 1230 2820 1230 2820 LOW 990 2190 990 2190 582J*04 MED 900 1500 1000 1550 1000 1550 HIGH — — — — —D LOW 990 2190 990 2190 cv TH REE in PHASE 582J*05 MED 1200 2000 1330 2460 1330 2460 � HIGH 1390 2220 1390 2220 LOW 990 2730 990 2730 582J*06 MED 1500 2500 1330 2880 1330 2880 HIGH 1390 2780 1390 2780 10 Table 7-PHYSICAL DATA (COOLING) 3 - 5 TONS . 582J*04 562J*05 582J*06 Refrigeration System #Circuits/#Comp./Type 1/1/Scroll 1/1/Scroll 1/1/Scroll Puron®refrig.(R-410A)1 phase (lbs-oz) 7.1 10.5 16.0 . Puron®refrig.(R-410A)3 phase (lbs-oz) 7.1 10.5 14.5 Perfect Humidity Puron®refrig.charge(lbs-oz) 10.4 15.3 26.0 Metering Device(A) Acutrol Acutrol Acutrol Perfect Humidity Metering Device(B) Acutrol+TXV Acutrol+TXV Acutrol+TXV High-press.Trip/Reset(psig) 630/505 630/505 630/505 Low-press.Trip/Reset(psig) 54/117 54/117 54/117 Compressor Capacity Staging(%) 100% 100% 100% Evap.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 3/15 3/15 4/15 Total Face Area(ft2) 5.5 5.5 7.3 Condensate Drain Conn.Size 3/4-in 3/4-in 3/4-in Perfect Humidity Coil Material(Tube/Fin) Cu/Al Cu/AI Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 3.9 3.9 5.2 Evap.Fan and Motor Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct a) Max BHP 1 1 1 LC) Standard RPM Range 600-1200 600-1200 600-1200 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.2 1.2 1.2 Medium RPM Range 560-854 560-854 770-1175 Static Motor Frame Size 48 48 48 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor.Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.5 1.5 1.5 High RPM Range 770-1175 770-1175 1035-1466 Static Motor Frame Size 56 56 56 1 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Direct 1/Direct 1/Direct Max BHP 1 1 1 Standard RPM Range 600-1200 600-1200 600-1200 Static . Motor Frame Size 48 48 48 3 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10 x 10 11 x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 1.7 1.7 2.9 Medium RPM Range 770-1175 920-1303 1035-1466 Static Motor Frame Size 48 56 56 3 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10 x 10 10x 10 10x 10 Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt Max BHP 2.9 2.9 2.9 High RPM Range 1035-1466 1208-1639 1303-1687 Static Motor Frame Size 56 56 56 3 phase Fan Qty/Type 1/Centrifugal 1/Centrifugal 1/Centrifugal Fan Diameter(in) 10x 10 10 x 10 10 x 10 Cond.Coil 1 phase Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 Total Face Area(ft2) 16.5 16.5 21.3 3 phase Material(Tube/Fin) Cu/Al Cu/AI Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows..Fins/in. 1/17 2/17 2/17 Total Face Area(ft2) 16.5 14.6 18.8 Cond.fan/motor Qty/Motor Drive Type 1/Direct 1/Direct 1/Direct Motor HP/RPM 1/8/825 1/4/1100 1/4/1100 , Fan diameter(in) 22 22 22 Filters RA Filter#/Size(in) 2/16 x 25 x 2 2/16 x 25 x 2 4/16 x 25 x 2 OA inlet screen#/Size(in) 1/20x24x1 1/20x24x1 1/20x24x1 11 Table 9—PHYSICAL DATA (HEATING-THREE PHASE UNITS) 3 - 5 TONS 582JE/P/T04 582JE/P/T05 582JE/P/T06 Electrical Three Phase Three Phase Three Phase Gas Connection #of Gas Valves 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4—13/0.18—0.47 4—13/0.18—0.47 4—13/0.18—0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#ofburners(total) 1or2/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT N CO MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 #of stages/#of burners(total) 1 or 2/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 • #of stages/#ofburners(total) — 1or2/3 1or2/3 Connection Size — 1/2—in NPT 1/2—in NPT I HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 50—80 40—80 Low NOx Gas Heat #of stages/#of burners(total) 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT LOW Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 20—50 20—50 15—50 #of stages/#of burners(total) 1/3 1/3 1/3 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT MED Rollout switch opens/closes 195/115 195/115 195/115 Temperature Rise 30—60 30—60 25—60 #of stages/#of burners(total) — 1/3 1/3 Connection Size — 1/2—in NPT 1/2—in NPT HIGH Rollout switch opens/closes — 195/115 195/115 Temperature Rise — 40—70 35—70 — Not applicable 13 582J NOTES: UN[TED P.O B01 ABBE THIS DOCUMENT IS IN[PROPERTY OI CARRIER CORIORAl10N SUBMISSION OF THESE DRAWINGS OR DOCUMENTS TUNETEDLOO IES SIRRCUER 80 D IS xMO UPON INF FNPRFBS[ONDI110X 1NAI 1rh,01 DB SUBMISSION CONS I IIUIF PARI AN OR MAXCE OR 1. DIMENSIONS ARE IN INCHES, DIMENSIONS _ UNIT J K I1 PHASE) K 13 PHASE) /CARRIER 1471( TDNIFNT [0 wt B[/A4LOSED OR USED WITHOUT CARRIER ACEFraz DF cONIRAct. IN[ I ARE IN MILLIMETERS. 33 3/8 14 7/8 14 7/8 CORPORATION'S WRITTEN COW.. 2.& CENTER OF GRAVITY _582J 04 [8471 13771 [3771 • 33 3/8 TA 7/8 18 5/8 CONNECTION SIZES 582J OS 18471 1317] 18721 A 1 3/8' 135]DIA FIELD POWER SUPPLY HOLE 3.00,DIRECTION OF AIR FLOW dt 318 f1 1/8 18 5/8 582J D6 [10511 [311] [4721 B 2' 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' 151]DIA GAUGE ACCESS PLUG D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE 33-3/8 [8481 E 3/4'-11 NPT CONDENSATE DRAIN F 1/2'-14 NPT GAS CONNECTION • I G 2 1/2' [641 DIA POWER SUPPLY KNOCK-OUT - 32-1/4 I ECONOMIZER HOOD 16 [818] /OPTIONAL) [4061 FILTER ACCESS PANEL I iXAU-iHE-BASE CNARi (TOOL-LESS) ((MRp. lir THESE HOLES REOUTAED FOR USE • ACCESS CONDENSER �--K •PANEL I COIL CRBTMPWR001A01, 003A01 `--1 THREADED WIRE REO'D HOLE INDOOR COIL '—_� I CONDUIT SIZE USE SIZES MX./ ACCESS PANEL I ��. W 1/2" ACC. 7/8' [22.2] I= IV���\� CA 25-5/e 10.7/8 ♦ X 1/2' 24V 7/8' [22.2] [6521 [2771 ~ i y �� RE7UflN AIR •_ RETURN Y * 3/4' (OOI,DD3) POWER 1 1/8" (28.4] BC. ��1\�/ AIR Z** (0037 1/2' FPi GAS 1 3/i6' [30.01 �y6 I [11171 \ �/ • FOR'THAU-THE-BASEPAN'FACTORY OPTION, p.$/g.! \� - _ FITTINGS FOR ONLY X,Y, d Z ARE PROVIDED g. �F��� M BACK 1671 U E ALT J * SELECT EITHER 3/4"OR 1/2" I1 `, TYP CURB 'W • CONDENSATE ^ FOR POWER, DEPENDING ON WIRE SIZE 61 3/dMIIIIII WIDTH I Y DRAIN BASEPAN 18511 29-3/8 ** 1001)PROVIDES 3/4"FPT TNRU CURB Y�1 ' _ SUPPLY 26-i/2 FLANGE d FITTING. 1T1 ti 18-1/8 Z AIR [6731 [711] SUPPLY �NYI{ [4591 _ AIR C4 ! 16-1/8 id-1/4 12-111 _. N [4111 [363] [3721 R SEE STHRUEC ATHERT 6-1/4 CA 0 ' BASE CN AAi _ •• [157 Rp A 12-1/8 --- [851 00 L E —_ 25 FLUE [3071 OS [6361 [1001 HOOD —18-1/2— E1 '4, K TOP 1/101 A 4-5/8 [26512 1-1/4 dRNwN6 .•R [1181 [321 l'A N ELECTRICAL p •� —= DISCONNECT Py -- I LOCATION .. r---7 CA N.+ CONDENSER -- E �, COIL =A. w II ACCESS LPANEL ACCESS BLOWER CONDENSATTE : FILTER I�I __8• � } DRAIN __ 11110 _ J •i `� • _- —_ ' 25. 25-1/8 I OUTSIDE O OPTIONAL = ——_=l . 16-3/1 RETURN INSTALLED == ,•k ==— F HANDLE [ SUAIR I441141 CON _-D ===OUTLET -__ DISCONNEti =--== ,I 21-1/4 0 -- 153191 ��.[ [ ..� [1681 I .1(](] =. 0() [1551 1 3-314 HANDLE 8-3/8 6-5/8 7 6 [95] 46-3/4 - 30-1/8-- [2131 [1691 11711 [1521 [11871 17641 26-7/8 74-3/8 [6821 BAROMETRIC [1888] 31-1/4 RELIEF [7931 FLOW SUPPLY RETURN LEFT FRONT AIR ♦ RIGHT AIR SHEET DATE SUPERcmEs 582J 04-06 SINGLE ZONE ELECTRICAL RIO 1OF 2 08-14-14 - COOLING WITH GAS HEAT 48KC000284 _ 0 NA V O -- UNITED P.O.905 4808 NIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SUBMISSIOND THESE DRANI G OR DOCUMENTS TECHNOLOGIES 55540501,NTAMD IS 001)00505 UPON THE(SPREES CONDITION THAT TNF DOES NO000X511EEE RAWINPER ORDOCUE OR STD. UNIT CORNER CORNER CORNER CORNER C.G. HEIGHT CARRIER 13221 CORPORATION'S WRITTEN CONSENTD DR USED nrx5ur uRR IER A[G EPrucE Or CONSRACI. UNIT WEIGHT WEIGHT (A) WEIGHT(B) WEIGHT IC) WEIGHT (D1 LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 582J 04 490 222 120 54 111 50 125 56 135 61 35 3/4 [9081 24 3/4[6281 18 7/8[479] 582J 05 544 246 130 58 126 57 142 64 146 66 36 3/4 [933] 24 3/4[6281 18 7/8[479] 582J 06 597 270 141 64 156 70 158 71 142 64 39 1/8[9931 23 1/2[5971 20 1/8[511] A STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER 8 1 • � 611."-- Ii til PIl 0 Z 4. VI Cli _ R, COD CORNER D N a CORNER C I-' O X ul A ll TOP 0 oN yrii m z N ll C OPy z ::oo i 1• i 'i•: •. ooh FRONT SHEET DATE SUPEHCEDES 582J 04-06 SINGLE ZONE ELECTRICAL REP 2OF2 08-14-14 - COOLING WITH GAS HEAT 486C000284 _ o A N J 582J 4 't4jr A N 03 LO C08337 LOCATION DIMENSION CONDITION 48—in(1219 mm) Unit disconnect is mounted on panel A 18—in(457 mm) No disconnect,convenience outlet option 18—in(457)mm Recommended service clearance 12—in(305 mm) Minimum clearance 42—in(1067 mm) Surface behind servicer is grounded(e.g.,metal,masonry wall) B 36—in(914 mm) Surface behind servicer is electrically non—conductive(e.g.,wood,fiberglass) Special Check sources of flue products within 10—ft of unit fresh air intake hood C 36—in(914 mm) Side condensate drain is used 18—in(457 mm) Minimum clearance 48—in(1219 mm) No flue discharge accessory installed,surface is combustible material D 42—in(1067 mm) Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) 36—in(914 mm) Surface behind servicer is electrically non—conductive(e.g.,wood,fiberglass) Special Check for adjacent units or building fresh air intakes within 10—ft(3 m)of this unit's flue outlet NOTE: Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or for vertical clearances. Fig.3 - Service Clearance Dimensional Drawing 16 ROOF CURBA NOTES'. CONNECTOR PKG.ACC. GAS CONNECTION TYPE GAS FITTING POWER WIRING CONTROL WIRING ACCESSORY CONVENIENCE ACCESSORY# 1.ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. FITTING FITTING OUTLET WIRING CONNECTOR 2.INSULATED PANELS'25.4[11 THK.POLYURETHANE FOAM,44.5[1-3/41#DENSITY. CRRFCURBOO1A01 14' 3.DIMENSIONS IN[]ARE IN MILLIMETERS. CRBTMPWROO1A01 THRU THE CURB 3/4"[19]NPT [356] 4.ROOFCURB:18 GAGE STEEL. 5.ATTACH DUCTWORK TO CURB.(FLANGES OF DUCT REST ON CURB). 3/4"[19]NPT 12"[12.7]NPT 1/2"[12.7]NPT CRRFCURROO2A01 [610] 6.SERVICE CLEARANCE 4 FEET ON EACH SIDE. CRBTMPWROD3A01 THRU THE BOTTOM 1/2"[12.7]NPT 7.=Or DIRECTION OF AIR FLOW. 8.CONNECTOR PACKAGE CRBTMPWRODIA01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWR003A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. 1-3/4" { [44.5] 1 I_1.00" 25.4] 5.42" 11.96" 11 3/4"[298.5]WIDE [137.7] ~_ [303.8] INSULATED DECK PANELS, 21.74" I [552.'2] >•/) �. 89/16"12170]WIDE v r INSULATED DECK PANEL I`I 1-3/d" I 1 . �'`� ` [44.4] 1'4-13/16" SEE NOTE#2 M .1•.• -i 11141I ' SECTION E-E ' 4.96" / GAS SERVICE PLATE [427]INSIDE SCALE 0.250 2-3/8" O [126.0] [1600.2] IY, THRU THE CURB I [61 yy 1 DRILL HOLED I I• ] 1M111/ C 11.1111111 . ASSEMBLY(IF �� I W �'9 REQUIRED) et yCr75.19" Iøh/341445uiVj [385.8] E E up d [7s.2] [554.7] ...' 32.19" Il , i 1624.6] VIEW"B' ISI Vr. CORNER DETAIL /`/ 14.00" SUPPLY AIR 16.03" RETURN AIR .�� 1-3/4" (n [355.fi] OPENINGCC [407 2] /"IN \ 144.4] 314" _[44.5] [7.75" L r-[20.41^] 40.fi9" �[35?0] (SUPPLIED WITH CURB) / UNIT NAIL(FIELD SUPPLIED) „ �I! A 44.5] A" CZN 5 7-3/8" O [1033.5] DVC 1,4 , TYPICAL(4)SIDES /�\ [17113] Z(FIELD SUPPLIED) 7/16" SCI) [111 3'-1 3/16" - ?UNTO FLASHING - 944.6] �- (FIELD SUPPLIED) _ /5.51 et ROOFING FELT SEE VIEW"B" Q (FIELD SUPPLIED) P.'1° CERTIFIED DRAWING I/4 CANT STRIP [7 01 , 1 (FIELD SUPPLIED) DRAWING RELEASE LEVEL: PRODUCTION a e/tR^ ]tls.sl 7 O ` ROOFING MATERIAL O ,� k` (FIELD SUPPLIED) Al UNLESSOTHERWISEARE INSPECIFIED S I PHIRD ROJECTIONEiD DIMENSIONS NCE IN INCHES / / I / \_ \`\\\\\ PROJECTION TOLERANCES srxoINFORWOON CONTAINED THERM MATERWL IDECAU„DEL 3OEC ANG wirrvourrx[WRIT.w�awuip o�cawa Fn copaoRAnox. }- A- A- t- -% / ` _ AUTHORIZATION NUMBER TITLE o a RETURN RIGID INSULATION - 1941738 CURB ASY,ROOF _ /////////////z SUPPLY AIR �\��'StS��\\ (FIELD SUPPLIED) - ENGINEERING MANUFACTURING x (0 REV07) ENGINEERING REQUIREMENTS - -- - SIZE DR j `\ OVERALL DIM.5'-7 3/8"WAS 5'-7 7/8:18GA T-005,Y-002 DRAFTER CHECKER DRAWING \ A MATERIAL WA 16 GA.,NAIL FIELD SUPPLIED WAS 04/22/13 MMC 1067898 WEIGHT:- MMC RA 06/17/11- - D s s B WITH CURB SURFACE FINISH MFGIPURc (INTERNAL USE ONLY) NEXT DRAWING OF REV REVISION RECORD DATE BY SHE'D APPS ECU No. PURCHH N/AE MMC _n CO W 0 582J OPTIONS &ACCESSORY WEIGHTS - OPTION/ACCESSORY WEIGHTS OPTION/ACCESSORY 04 05 06 lb kg lb kg lb kg Perfect Humidity1 50 23 50 23 55 25 Power Exhaust—vertical 45 20 45 20 45 20 Power Exhaust—horizontal 30 14 30 14 30 14 EconoMi$er(IV,X or 2) 35 16 35 16 35 16 Two Position damper 39 18 39 18 39 18 Manual Dampers 12 5 12 5 12 5 Medium Gas Heat 12 5 9 4 9 4 High Gas Heat — — 17 8 17 8 Hail Guard(louvered) 13 6 13 6 17 8 Cu/Cu Condenser Coil2 37 17 74 34 95 43 Cu/Cu Condenser and Evaporator Coils2 75 34 112 51 165 75 WRoof Curb(14—in.curb) 115 52 115 52 115 52 Roof Curb(24—in.curb) 197 89 197 89 197 89 CO2 sensor 2 1 2 1 2 1 Flue Discharge Deflector 7 3 7 3 7 3 Optional Indoor Motor/Drive 6 3 6 3 17 8 Motor Master Controller 9 4 9 4 9 4 Return Smoke Detector 7 3 7 3 7 3 Supply Smoke Detector 7 3 7 3 7 3 Non—Fused Disconnect 5 2 5 2 5 2 Powered Convenience outlet 36 16 36 16 36 16 Non—Powered Convenience outlet 4 2 4 2 4 2 Enthalpy Sensor 2 1 2 1 2 1 Differential Enthalpy Sensor 3 1 3 1 3 1 NOTE:Where multiple variations are available,the heaviest combination is listed. — Not Available 1 For Perfect Humidity add MotorMaster Controller. 2 Where available. 18 -7( 6,-_ ,t,..., vim, • 580J GAS HEAT/ELECTRIC COOLING `. } PACKAGED ROOFTOOP y ` 3 TO 15 NOMINAL TONS a Product Data I 4EG GTM 1 a a �r /� ... .. r� c \� 5 tib>. /i iiii ,,4,4;:j.e.kr-,,,,,,,,,,-:,,, ,,':,,,ir.,i,11:,,,,,‘,S,c17'.7.;,. ,,,,,7::;,r,..711.- -tra,A.74:174111,,g IltitiiiiMilkil 11;:--215,11F,',..liin s \ FsK i*i 'r � .\f r\fi,•• ,,W ' r , 1i4bv 01,� ,' rw Pc C08515�� �� k ...,ItolL.::4;,.-,.."--44-risil...„41)),/4'1:1'4,1, 4'. ma (Unit shown with louvered hail guard.) (!_s-) ,, HME Duron COMPLIAMI FEATURES AND BENEFITS • • Single cooling stage models are available from 3 - 10 ton. •Two cooling stage models are available from 7.5- 15 ton. • SEER up to 13.0. • EER's up to 11.1. • IEER's up to 11.8 with single speed indoor fan motor and up to 12.8 with 2-speed/VFD indoor fan motor. • Up to 28%lighter than similar industry units.Lighter rooftops make easier replacement jobs. •Utility connections are the same because 3 - 12.5 ton units fit on existing Bryant rooftop curbs.This saves time and money on replacement jobs. • Standardized components and layout. Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units.This makes service,stocking parts,replacement,and troubleshooting easier. • Field convertible airflow(3 - 15 ton).Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical to horizontal. • Easy-adjust,belt-drive motor available. • Provisions for bottom or side condensate drain. • Capable of thru-the-base or thru-the-curb gas line routing. • Single-point gas/electrical connection. • Sloped,composite drain pan sheds water;and won't rust. • Standardized controls&control box layout.Standardized components&controls make stocking parts&service easier. •Tool-less filter access door. • Clean,large,easy to use control box. • Color-coded wiring. •Large,laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single,central terminal board for test and wiring connections. • Fast-access,handled,panels for easy access on normally accessed service panels. •"No-strip"screw system guides screws into the panel&captures them tightly without stripping the screw,the panel,or the unit. • Mechanical cooling(115°F to 40°F or 46°C to 4°C)standard on all models.Winter Start Kit allows cooling operation down to 25°F(-4°C)and MotorMaster to-20°F(-29°C). • High efficiency,gas heat with induced-draft flue exhaust design. •Induced draft motor ensures no flue gas can escape into the indoor air stream. •Bryant designed naturally draining heat exchanger,unlike positive pressure heat exchangers,do not need to be periodically,manually drained.This saves labor and maintenance expense. • 2-in(51mm)disposable filters on all units. • Refrigerant filter-drier on each circuit. • Each circuit is protected with a high and low pressure switch. • Many factory-installed options ranging from air management economizers,2 position dampers,plus convenience outlets,disconnect switches and smoke detectors. • Standard(parts only)Warranty: 10 yr. aluminized heat exchanger,5 yr.compressor,3 yr. Novation condenser coil, 1 yr. parts. • Factory-installed Perfect Humidity dehumidification system on all sizes with round tube/plate fin condenser coils, includes MotorMaster I controller. • Optional 2-Speed Indoor Fan Motor System utilizes a Variable Frequency Drive(VFD)to automatically adjust the indoor fan motor speed between cooling stages.Available on 2-stage cooling models 08-16 with electromechanical controls or RTU Open. 3 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516 17 580 J E 06 A 072 A 1 B OA A Packaging and Indoor Fan Motor Speed Options A-Standard Packaging,electro mech controls that require W7212 EconoMi$er IV B-LTL Packaging,electro mech controls that require Unit Type W7212 EconoMi$er IV Gas Heat RTU C-Standard Packaging,electro mech controls that require Legacy Series W7220 EconoMi$er X Model D-Standard Packaging and 2-Speed Indoor Fan Motor J-Puron Refrigerant NFD)Controller Voltage indoor fan motor E=460-3-60 E-LTL Packaging and 2-Speed Indoor Fan Motor(VFD) Controller J=208/230-1-60 F-LTL Packaging,electro mech control that require W7220 P=208/230-3-60 EconoMi$er X T-575-3-60 Cooling Tons Factory Installed Options 04-3 ton 09-8.5ton 05-4ton 12-10 ton 06-5 ton Outdoor Air Options 07-6ton 14-12.5 ton A=None 16-15 ton B=TempEcono,Baro Relief,Standard Leak(W7212 and 08-7.5 ton W7220) E=Temp Econo,Baro Relief,Standard Leak w/CO2(W7212 or W7220) Refrig.System/Gas Heat Option H=Enthalpy Econo,Baro Relief,Standard Leak(W7212 or W7220) A=Standard One Stage cooling L=Enthalpy Econo,Baro Relief,Standard Leak w/CO2(W7212 or W722) models/Nat.Gas Heat Q=Motorized 2 Position Damper B=Standard One Stage cooling U=Temp Econo,Baro Relief,Ultra Low Leak,(W7220) models/Low NOx heat W=Enthalpy Econo Baro Relief,Ultra Low Leak,(W7220) C=Standard One Stage cooling Indoor Fan Options models/SS HX Heat 1 =Standard Static Option D=Two stage cooling models 08-16 2=Medium Static Option G=One-stage cooling models/Alum 3=High Static Option Heat Exchanger with Perfect Humidity(04-07) C=High Static Option w/High Effy Motor-Belt H=One-stage cooling models/Low NOx Drive(16 size only) Heat with Perfect Humidity(04-07) J=One-stage cooling models/Stainless Coil Options For Round Tube/Plate Fin Condenser Coil Models Only Steel Exchanger with Perfect (outdoor-indoor-hailguard) Humidity(04-07) A=Al/Cu-Al/Cu F=Two stage cooling models and Stainless B=Precoat Al/Cu-Al/Cu Steel gas heat exchanger(08-16) C=E-coat Al/Cu-Al/Cu K=Two stage cooling models/Alum gas heat D=E-coat Al/Cu-E-coat Al/Cu • exchanger with Perfect Humidity(08-16) E=Cu/Cu-Al-Cu M=Two stage cooling models/Stainless steel F=Cu/Cu-Cu/Cu gas heat exchanger with Perfect M=Al/Cu-Al/Cu-Louvered Hail Guards Humidity(08-16) N=Precoat Al/Cu-Al/Cu-Louvered Hail Guards P=E-coat Al/Cu-Al/Cu-Louvered Hail Guards Heat Level Input Q=E-coat Al/CU-E-coat Al/Cu-Louvered Hail Guards Standard/Stainless Steel R=Cu/Cu-Al/Cu-Louvered Hail Guards 072-72,000 224=224,000 S=Cu/Cu-Cu/Cu-Louvered Hail Guards 115=115,000 240=240,000 120=125,000 250=250,000 150=150,000 350=350,000 Coil Options For All Aluminum-Novation Condenser Coil Models Only 180=180,000 (outdoor-indoor-hailguard) G=Al/AI-Al/Cu Low Nox H=AI/AI-Cu/Cu 060=60,000 J=AI/AI-E-Coat Al/Cu 090=90,000 K=E-coat AI/AI-Al/Cu 120=120,000 L=E-coat AI/AI-E-coat Al/Cu T=AI/AI-Al/Cu,Louvered Hail Guards Note:On single phase(-J voltage code)models,the U=AI/AI-Cu/Cu,Louvered Hail Guards following are not available as a factory installed option V=Al/AI-E-coat Al/Cu,Louvered Hail Guards -Perfect Humidity W=E-coat AI/AI-Al/Cu,Louvered Hail Guards -Coated Coils or Cu Fin Coils X=E-coat AI/AI-E-coat Al/Cu,Louvered Hail Guards -Louvered Hail Guards -Economizer or 2 Position Damper -Powered 115 Volt Convenience Outlet C14177 4 Table 2-AHRI COOLING RATING TABLE NET IEER WITH IEER WITH NOM. TOTAL UNIT COOLING CAPACITY COOLING POWER SEER EER SINGLE SPEED 2-SPEED STAGES CAPACITY ,,,, INDOOR INDOOR - (TONS) (MBH) IMOTOR MOTOR 04A 1 3 34.6 3.1 13.0 11.00 N/A N/A 05A 1 4 45.0 4.0 13.0 11.00 N/A N/A 06A 1 5 59.0 5.5 13.0 10.75 N/A N/A 07A 1 6 70.0 6.4 N/A 11.00 11.2 N/A 08A 1 7.5 88.0 8.0 N/A 11.00 11.2 N/A 08D 2 7.5 83.0 7.5 N/A 11.00 11.7 12.8 09A 1 8.5 97.0 8.8 N/A 11.00 11.2 N/A 09D 2 8.5 99.0 9.0 N/A 11.00 11.7 12.8 12A 1 10 117.0 10.6 N/A 11.00 11.2 N/A 12D 2 10 114.0 10.3 N/A 11.10 11.8 12.8 14D 2 12.5 140.0 12.9 N/A 10.80 11.0 11.8 16D 2 15 174.00 16.1 N/A 10.80 11.7 12.4 LEGEND NOTES: AHRI - Air Conditioning,Heating and Refrigeration 1. Rated in accordance with AHRI Standard 210/240 or Institute Test Standard 340/360,as appropriate. ASHRAE - American Society of Heating,Refrigerating 2. Ratings are based on: and Air Conditioning,Inc. Cooling Standard:80°F(27°C)db, 67°F(19°C) wb indoor EER - Energy Efficiency Ratio air temp and 95°F(35°C)db outdoor air temp. IEER - Integrated Energy Efficiency Ratio IEER Standard: A measure that expresses cooling part- N/A - Not Applicable load EER efficiency for commercial unitary air conditioning SEER - Seasonal Energy Efficiency Ratio and heat pump equipment on the basis of weighted opera- tion at various load capacities. 3. All 580J units comply with ASHRAE 90.1 Energy Standard for minimum SEER and EER requirements. as 4. 580J units comply with US Energy Policy Act(2005).To eval- "' uate code compliance requirements, refer to state and local C PI USc codes. COMPPPIANT 1 CERTIFIED Use of the AHRI Certlfietl TM Mark intlicates a nufaclurer's participation in the C US pprogram Fo verficafion t certification fpr intlivitlual pr°dThs,go to tISTS0 www.ehntlirectory.org. 9 • Table 3-HEATING RATING TABLE-NATURAL GAS&PROPANE AL/SS HEAT EXCHANGER TEMP RISE THERMAL AFUE UNITS GAS HEAT INPUT/OUTPUT INPUT/OUTPUT (DEG F) EFFICIENCY (off) (%)1 (MBH) STAGE 2(MBH) LOW - 72/56 25-55 82% 79.1% 04 MED - 115/89 55-85 80% 78.5% a, HIGH - - - - - a $ LOW - 72/56 25-55 82% 79.1% a 05 MED - 115/90 35-65 81% 79% ar C HIGH - 150/117 50-80 80% 78.8% in LOW - 72/56 20-55 82% 79.1% 06 MED - 115/90 30-65 81% 79% HIGH - 150/117 40-80 80% 78.8% LOW - 72/56 25-55 82% N/A 04 MED 82/66 115/89 55-85 80% N/A HIGH - - - - - LOW - 72/56 25-55 82% N/A 05 MED - 115/90 35-65 81% N/A HIGH 120/96 150/117 50-80 80% N/A LOW - 72/56 20-55 82% N/A 06 MED - 115/90 30-65 81% N/A HIGH 120/96 150/117 40-80 80% N/A LOW - 72/59 15-55 82% N/A 07 MED - 115/93 25-65 81% N/A v HIGH 120/96 150/120 35-80 80% N/A uu LOW - 125/103 20-50 82% N/A a 08 MED 120/98 180/148 35-65 82% N/A 22 HIGH 180/147 224/184 45-75 82% N/A r I- LOW - 125/103 20-50 82% N/A 09 MED 120/98 180/148 30-65 82% N/A HIGH 180/147 224/184 40-75 82% N/A LOW 120/98 180/148 25-65 82% N/A 12 MED 180/147 224/184 30-65 82% N/A HIGH 200/160 250/205 35-70 80% N/A LOW 120/98 180/148 20-65 82% N/A 14 MED 180/147 224/184 25-65 82% N/A HIGH 200/160 250/205 25-70 80% N/A LOW 144/118 180/146 15-55 81% N/A 16 MED 192/156 240/195 20-60 81% N/A HIGH 280/224 350/280 35-65 80% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft(610 m).For information on propane or altitudes above 2000 yt(610 m),see the Application Data section of this book.Accessory Propane/High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft(610m)must be derated by 4%for each 1000 ft(305 m)above sea level.In Canada, the input rating must be derated by 10%for altitudes of 2000 ft(610 m)to 4500 ft(1372 m)above sea level. 10 Table 7-PHYSICAL DATA (COOLING) 3 - 6 TONS 580J*04A 580J*05A 580J*06A 580J*07A Refrigeration System #Circuits/#Comp./Type 1/1/Scroll 1 /1/Scroll 1 /1/Scroll 1 /1 /Scroll Puron 8 refrig.(R-410A)(lbs-oz) 5-10 8-8 10-11 14-2 Perfect Humidity Puron®refrig.charge NB(lbs- 8-11 14-13 16-0 22-5 oz) Metering Device Acutrol Acutrol Acutrol Acutrol High-press.Trip/Reset(psig) 630/505 630/505 630/505 630/505 Low-press.Trip/Reset(psig) 54/117 54/117 54/117 54/117 Compressor Capacity Staging(%) 100% 100% 100% 100% Evap.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 2/15 2/15 4/15 4/15 Total Face Area(ft2) 5.5 5.5 5.5 7.3 Condensate Drain Conn.Size 3/4-in 3/4-in 3/4-in 3/4-in Evap.Fan and Motor o Motor Qty/Drive Type 1/Belt 1 /Belt 1/Belt - in w Max BHP 1.2 1.2 1.2 - 12 r RPM Range 560-854 560-854 770-1175 - -as a Motor Frame Size 48 48 48 - m Fan Qty/Type 1 /Centrifugal 1 /Centrifugal 1 /Centrifugal - io Fan Diameter(in) 10 x 10 10 x 10 10 x 10 - Motor Qty/Drive Type 1/Belt 1/Belt 1/Belt - .iU> Max BHP 1.2 1.2 1.5 - ELRPM Range 770-1175 770-1175 1035-1466 - o n Motor Frame Size 48 48 56 'a- Fan Qty/Type 1/Centrifugal 1 /Centrifugal 1 /Centrifugal - M Fan Diameter(in) 10 x 10 10 x 10 10 x 10 - y Motor Qty/Drive Type 1 /Belt 1/Belt 1 /Belt 1/Belt Id Max BHP 1.7 1.7 1.7 2.4 w a) v 0 RPM Range 560-854 560-854 770-1175 1073-1457 L Motor Frame Size 48 48 48 56 ao a Fan Qty/Type 1 /Centrifugal 1/Centrifugal 1/Centrifugal 1 /Centrifugal w Fan Diameter(in) 10x10 10x10 10x10 10x10 v Motor Qty/Drive Type 1 /Belt 1 /Belt 1 /Belt 1/Belt _m a, Max BHP 1.7 1.7 2.4 2.9* 0 RPM Range 770-1175 770-1175 1035-1466 1173-1518 7 a Motor Frame Size 48 48 56 56 0 m Fan Qty/Type 1 /Centrifugal 1/Centrifugal 1/Centrifugal 1 /Centrifugal M Fan Diameter(in) 10 x10 10 x 10 10 x 10 10 x 10 Motor Qty/Drive Type 1/Belt 1 /Belt 1 /Belt 1/Belt 0Max BHP 2.4 2.4 2.9 3.7 co w 0 RPM Range 1035-1466 1035-1466 1303-1687 1474-1788 s a Motor Frame Size 56 56 56 56 0c, xFan Qty/Type 1 /Centrifugal 1/Centrifugal 1/Centrifugal 1 /Centrifugal Fan Diameter(in) 10 x 10 10 x 10 10 x 10 10 x10 Cond.Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Cu/Al Coil type 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF 3/8-in RTPF Rows/FPI 1/17 2/17 2/17 2/17 Total Face Area(ft2) 14.6 16.5 16.5 21.3 Perfect Humidity Coil Material(Tube/Fin) Cu/Al Cu/Al Cu/Al Cu/Al Rows..Fins/in. 1/17 2/17 2/17 2/17 Total Face Area(ft2) 3.9 3.9 3.9 5.2 Cond.fan/motor Qty/Motor Drive Type 1/Direct 1/Direct 1/Direct 1/Direct Motor HP/RPM 1/4/1100 1/4/1100 1/4/1100 1/4/1100 Fan diameter(in) 22 22 22 22 Filters RA Filter#/Size(in) 2/16x25x2 2/16x25x2 2/16x25 x2 4/16x16x2 OA inlet screen#/Size(in) 1 /20x24x1 1/20x24x1 1/20x24x1 1 /20x 24x1 NOTE:Perfect Humidity is not available with Novation condenser coil models,only Round Tube/Plate Fin(RTPF). * 575V motor utilizes 3.7 BHP. • - Not applicable 13 r . Table 8—PHYSICAL DATA (HEATING) 3 - 6 TONS 580J*04 580J*05 580J*06 580J*07 Gas Connection #of Gas Valves 1 1 1 1 Nat.gas supply line press(in.w.g.)/(PSIG) 4-13/0.18-0.47 4-13/0.18-0.47 4-13/0.18-0.47 4-13/0.18-0.47 LP supply line press(in.w.g.)/(PSIG) 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 11 —13/0.40—0.47 Heat Anticipator setting(Amps) 1st stage 0.14 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 0.14 Natural Gas Heat #of stages/#of burners(total) 1 /2 1 /2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT 1/2—in NPT 8 Rollout switch opens/closes 195/115 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 15—55 #of stages/#of burners(total) 1 or 2/3 1/3 1 /3 1/3 o Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT 1/2—in NPT Lu 2 Rollout switch opens/closes 195/115 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 25—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 2/3 = Connection Size — 1/2—in NPT 1/2—in NPT 1/2—in NPT = Rollout switch opens/closes — 195/115 195/115 195/115 Temperature Rise — 50—80 40—80 35—80 Liquid Propane Heat #of stages/#of burners(total) 1/2 1/2 1/2 1/2 Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT 1/2—in NPT 8 Rollout switch opens/closes 195/115 195/115 195/115 195/115 Temperature Rise 25—55 25—55 20—55 15—55 1 #of stages/#of burners(total) 1 or 2/3 1 /3 1 /3 1 /3 Lu Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT 1/2—in NPT 2 Rollout switch opens/closes 195/115 195/115 195/115 195/115 Temperature Rise 55—85 35—65 30—65 25—65 #of stages/#of burners(total) — 1 or 2/3 1 or 2/3 2/3 = Connection Size — 1/2—in NPT 1/2—in NPT 1/2—in NPT . 2 Rollout switch opens/closes — 195/115 195/115 195/115 Temperature Rise — 50—80 40—80 35—80 Low NOx Gas Heat #of stages/#of burners(total) 1 /2 1/2 1 /2 — Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT — 9 Rollout switch opens/closes 195/115 195/115 195/115 — Temperature Rise 20—50 20—50 15—50 — #of stages/#of burners(total) 1/3 1 /3 1 /3 — Lu Connection Size 1/2—in NPT 1/2—in NPT 1/2—in NPT — 2 Rollout switch opens/closes 195/115 195/115 195/115 — Temperature Rise 30—60 30—60 25—60 — #of stages/#of burners(total) — 1/3 1 /3 — = Connection Size — 1/2—in NPT 1/2—in NPT Rollout switch opens/closes — 195/115 195/115 — Temperature Rise — 40—70 35—70 - - Not applicable 14 NOTES: I, DIMENSIONS ARE IN INCHES, DIMENSIONS UNIT 1 N IN I I ARE IN MILLIMETERS. 580J-OAR 33 3/8 18 518 2. S CENTER OF GRAVITY 3[;43 IS 1[447218 CONNECTION SIZES 580J-05A 18411 ,3771 A 1 3/8" (351 DIA FIELD POWER SUPPLY HOLE 3.y DIRECTION OF AIR FLOW 5801-ERA 33[Sdi/8 3 1143777]/8 8 2" [501 DIA POWER SUPPLY KNOCKOUT l 5801-OIA 4[11 05/A 3lA1371]1/8 C 1 3/4' 1511 DIA GAUGE ACCESS PLUG 11 D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE 33-3/8 18481 E 3/4"-74 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION • —{ 0 2 Ill" 1641 DIA POWER SUPPLY KNOCK OUT 32-1/4 ECONOMIZER HOOD 161 [8181 (OPTIONAL] 14061 FII TR EOOL-LESACCESS S]PANEL COMPI iNRUTHE-BASE CHART (T . THESE HOLES REQUIRED FOR USE Fwd • • ACCESS CONDENSER (A CRBTMPWROOIA01, 003A01 '(w�] PANEL •.. - • •• •• •s COIL '�`' •-8 d • 4; I THREADED WIRE REO'D HOLE INDOOR COIL * CONDUIT SIZE USE SIZES IMAX.) '^ ACCESS PANEL I . T� \ W 112" ACC. Ile" 122.21 V1 I— \\ 25-5/8 70-718 ♦ % t/2' 2dV 7/8" 122.21 ___ II. tllll(l�l/(��� RETURN LAIR • [2771 RETURN Y. 3/a' 1001,0031 POWER I 1/8" [28.d1 (•I• ---��j�]II$1 d4 NN `1�y,` - N AlR Z*" 10031 1/2'FPT GAS 1 3/16• [30.01 ~ 2-5/8.d 111111 \`�,,:`\ f FOR INGSDFORE-NLYEPAN'FACTORY OPTION, tt 1 BACK [671 \�\;�i p}Q - FITTINGS FOR ONLY%.Y, d I ARE PROVIDED �/y�l C P E ALO. J i FOR POWSELEER,CT EDIEPENDING ON WIRETHER 3/4.OR I2 SIZE CURB { t �W CONDENSATE 17.3/4 SI' *" WIDTH % DRAIN OPENING [4571 10011 PROVIDES 3/4'FPI THRU CURB !9 Y IN BASEPAN SUPPLY 26-1/2 29 718 FLANGE 6 FITTING. 0 18-1/8 } I AIR [6731 [7471 SUPPLY y [4591 , AIR r� O 16-118 14-114 12-1/d _ t V1 ,6111 13631 [7121 1 SE BASE RCHART fil 00 I� 3-3/8 25 UE Cq [3011 8 [851 Oli A [6361 -~, 11001i8-112 —.3TOP 1101 O K I� 0 1!2 �1 4-5/8 1-114 2651 11181 32, • • m ELECTRICAL . .. --- DISCONNECT ' LOCATION 7 t CAiwi CONDENSER ��II CONTROL BOX INDOOR BLOWER E STD FILTER O COIL —=_. —A, ACCESS PANEL ACCESS CONDENSATE _ . DAA[N —_=G —_ - —__ 1 ZS-1 l8 �� 1 _ RETU1 OUTSIDE V1 OPTIONAL = ( _—_ _ 16-3/4 RETURN AIR FACTORY == IIII, OPTIONAL ——— •— INS7ALLED =_ 19-112 FACTORY —__— = F ac: zHANDLE 117/8 SUPPLY IR AIR CONVENIENCE _=D I 14941 INSTALLED =-..---.....-...=...-- I _ (2891 'I \ �� I OUTLET _ • ,I 6-5/8 DISCONNECT I=__ `a =.._ Q _J ,� 153914 7___ 11681 q n 6-1/8 '"' .''.''"'7"----""'"'"" '"'' ' El:.[.. .ri.:� IR 00 .r .�: 00 1,55] C 1 3.3/4 HANDLE 8.3/8 6.5/8 7 6 1951 46-3/4 30-1/8 1213] 11681 11771 [7641 [1521 111811 263/4 74-3/8 [681] BAROMETRIC 118881 31.1/4 RELIEF 17931 FLOW SUPPLY RETURN LEFT FRONT AIR i RIGHT AIR 0 N • N 01 4 . CURBS, WEIGHTS & DIMENSIONS (cont.) STD UNIT CORNER CORNER CORNER CORNER C.G. HEIGHT UNIT WEIGHT WEIGHT (A) WEIGHT (Al WEIGHT (C) WEIGHT (D) LBS. NO LBS. KG. LDS. KG. LBS. KG. LBS. KG. A Y 2 • 580J-04A 483 219 111 50 125 57 131 59 116 53 39 1991] 23 [564] 16 3/6 [1161 5905-059 537 244 124 56 139 63 145 66 129 59 39 [9911 23 1584] 17 [432] 580J-06A 569 258 131 59 147 67 154 70 137 62 39 [991] 23 15841 17 1/4 14381 580J-074 652 296 150 68 169 76 176 80 157 71 39 [991] 23 [584] 20 1/8 [511] CORNER A CORNER B O kr =.....-... =_ g A-- : m= 1 o l . . . foo .i. .i. o : : oo CORNER D � - -__-- - --___--' CORNER C FRONT N TOP C101226 Fig.2- Dimensions 580J 04-07 , '� D '. • „.-.--• 0 . - i GIr C08337 Fig.3- Service Clearance LOC DIMENSION I CONDITION 48-in(1219 mm) Unit disconnect is mounted on panel A 18-in(457 mm) No disconnect,convenience outlet option 18-in(457 mm) Recommended service clearance 12-in(305 mm) Minimum clearance 42-in(1067 mm) Surface behind servicer is grounded(e.g.,metal,masonry wall) B 36-in(914 mm) Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special Check for sources of flue products within 10-ft of unit fresh air intake hood C 36-in(914 mm) Side condensate drain is used 18-in(457 mm) Minimum clearance 48-in(1219 mm) No flue discharge accessory installed,surface is combustible material D 42-in(1067 mm) Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) 36-in(914 mm) Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special Check for adjacent units or building fresh air intakes within 10-ft of this unit's flue outlet NOTE: Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. 20 ROOF CURB NOTES: ACCESSORY# A 1.ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2.INSULATED PANELS:25.4111 THK.POLYURETHANE FOAM,44.511-3/4)#DENSITY. CONNECTOR PKG.ACC. GAS CONNECTION TYPE GAS FITTING POWER WIRING CONTROL WIRING ACCESSORY CONVENIENCE CRRFCURB001A01 14" 3.DIMENSIONS IN 1 I ARE IN MILLIMETERS. FITTING FITTING OUTLET WIRING CONNECTOR [3561 4.ROOFCURB:18 GAGE STEEL. 24" 5.ATTACH DUCTWORK TO CURB.(FLANGES OF DUCT REST ON CURB). CRBTMPWR001A01 THRU THE CURB 3/4"[19]NPT CRRFCURB002A01 6.SER CE CLEARANCE 4 FEET ON EACH SIDE. [610) 7. DIRECTION OF AIR FLOW. 3W[19]NPT 1/21[12.7]NPT 1/2"[12.71 NPT 8.CONNECTOR PACKAGE CRBTMPWROO/A01 IS FOR THRU-THE-CURB GAS TYPE CRBTMPWR003A01 THRU THE BOTTOM 1/2"[12.7]NPT PACKAGE CRBTMPWR003A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. 1-4.5- II [25] 113/4/298.51 WIDE V SA] 31.96' t- INSULATED DECK PANELS [137.]] [303.81 CM tt A 21.74" ~ ^ 1 [552.2] y 1 89/165217.$]WIDE L OINSULATED DECK PANEL / 4.4 OII" ` [44.41] SEE NOTE#2 1'4-13116' SESCAL E-E GAS SERVICE PLATE [427]INSIDE 2-318" CA SCALE 0.250 I [61] Ki 4.96 70 Or THRU THE CURB tr [126.0] 11800.21 lIlla011. 20 22[50[ .\ L ASSEMBLY(IF �� REQUIRED) .N-. K (SEE NOTE#e) I� 1 I RETURN AIR u y OPENING �' S 15.19" q}1/3/4"146.4 1 1385.8] E E `� 1110-,..- l J 1 r .00" 21.84' -A N ' 1 1 [76.21 1554.71 ez L t.-.� 32.19" z # le17s1 VIEW"B" ...''''..4111.1110,""----- %"/ r^ 1 CORNER DETAIL A 14.00" I SUPPLYAIR [107.21 \' RETURN AIR �j4144.41 [355.6] 1 OPENING 4 / / O 4" 7 � 1 � 1 �\ 144.5] Cr 1 v� 1,75" 20.41" -� 3.00' GASKE UNIT "A" [44.5] [518.31 [762] (SUPPLIED WITH CURB) ....13.78" v �I^ NAIL(FIELD SUPPLIED) I v 7-3/6- l 40.69" 1350.01 DUG TYPICAL VI)SIDES [17131 0 (FIELD SUPPLIED) 7/16" ►•i 111J 3'-1 3lifi' rr OUNTER FLASHING [944.6] (FIELD SUPPLIED) ♦ \� S. ROOFING FELT SEE VIEW"B" (FIELD SUPPLIED) CERTIFIED DRAWING CNT STRIP p ELD LIED) 118581 1'01 I�lll , \\ (FIELD SUPPLIEp�AL ( ELD SUPPLY AIR RETURN AIR RIGID INSULATION DRAWING 48TC400427 B (FIELD SUPPLIED) n A -4 YCC060-SF-1 A SERVICE Library Service Literature Product Section UnitarA FACTSProduct Model Packaged Gas/Electric: YCC 1110 Literature Type Service Facts Contains wiring and service information Sequence 1A Date January 1992 File No. SV-UN-RT-YCC060-SF-1A 1192 Supercedes New Model: YCC060F1 MOA Single Packaged Gas Electric YCC060F1 MPA - Convertible 5 Ton IMPORTANT- This Document is customer property and is to remain with this unit. Please return to service information upon completion of work. PRODUCT SPECIFICATIONS MODEL YCC060F1 MODEL YCC060F1 RATED Volts/Ph/Hz 208.23011x'60 OUTDOOR FAN—TYPE Propeller RATINGS(COOLING) E No.Used/Dia.(in.) 1/22 BTUH 60000 Type DriveiNo.Speeds Direct/1 Indoor Airflow(CFM) 2000 No.Motors—HP 1—1/2 Power Input(KW) 6.87 Motor Speed R.P.M. 1080 EER/SEER(BTU/Watt-Hr.) 8.83/9.70 Volts/Ph/Hz 200.230/1/60 Noise Rating No.( 8.4 F.L.Amps—LB.Amps 3.3/3.9-8.5 RATINGS(HEATING) a INDOOR FAN—TYPE Centrifugal (HIGH)Input BTUH 125000 Dia x Width(in.) 11x 11 Capacity BTUH 4 100000 No.Used 1 Temp.Rise @ Rated Airflow 46 Drive/Speeds(No.) Direct/2 (LOW)Input BTUH 100000 No.Motors—HP 1—3/4 Capacity BTUH 4 80000 Motor Speed R.P.M. 1080 •Type of Gas Si Natural Volts/Ph/Hz 200-230/1/60 POWER CONN.V/Ph/Hz 208-230/1/60 F.L.Amps—LR.Amps 5.0/4.3-9.7 Min.Brch.Cir.Ampaaty 41.5 COMBUSTION FAN—TYPE Centrifugal Fuse Size—Max.(amps) 60 Type Drive Direct COMPRESSOR No.Used—No.Speeds 1—1 - No.Used 1 Motor HP—RPM 1/35—3480 Volts/Ph/Hz 200-230/1/60 Volts/Ph/Hz 208-240/1/60 R.L.Amps—L.R.Amps 26.1—141 FLA .6 OUTDOOR COIL—TYPE Plate Fin FILTER/FURNISHED? No Rows/F.P.I. 3/15 Type Recommended Throwaway Face Area(sq.ft) 92 Miry.Face Area 6.67 sq.in. Tube Size(in.) 0.375 REFRIGERANT INDOOR COIL—TYPE Plate Fin Charge(lbs of R-22) 3 10.1 Rows/F.P.I. 4/15 GAS PIPE SIZE 1/2" Face Area(sq.ft.) 5.4 DIMENSIONS H X W X D Tube Size(in.) 0.375 Crated(in.) 39-3/8 x 47 x 66-1/4 Refrigerant Control TXV BLEED Uncrated See Outline Drawing Drain Conn.Size(in.) 3/4 FEMALE WEIGHT Duct Connections See Outline Drawing Shipping(Ibs.)/Net(lbs.) 610/558 T Rated in accordance with ARA.Standard 210.Noise rated in accordance with A.R.I.Standard 270. Al Models am American Gas Association Certified.Ratings shown are for elevations up to 2000 ft.For higher elevations, reduce ratings ata rate of 4%per 1000 ft.elevation. Convertible to LPG. This value is appoximate.For more precise value,see Unit Nameplate. Based on U.:.Government Standard Tests. `. WARNING ! IMPORTANT VICES THUS INFORMATE ION IS INTENDED FOR USE BY INDIVIDUALS HAZARDOUS VOLTAGE ALL PARTS OFRECONNECTLL TH IS PRODUCTING CAPABLE OF POSSESSING ADEQUATE BACKGROUNDS OF ELECTRICAL AND DISCONNECT POWER CONDUCTING ELECTRICAL CURRENT ARE MECHANICAL EXPERIENCE.ANY ATTEMPT TO REPAIR A CEN- GROUNDED.IF G ROUNDING WI RES,SCREWS. 0TRALAIRCONDITIONINGPRODUCTMAYRESULTINPERSONAL BEFORE SERVICING. STRAPS,CLIPS,NUTS OR WASHERS USED TO INJURYAND/OR PROPERTY DAMAGE.THE MANUFACTURER OR Failure to DISCONNECT POWER before COMPLETE A PATH TO GROUND ARE ITE- SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRETATION servicing can cause severe personal injury or MOVED FOR SERVICE, THEY MUST BE IRE- OF THIS INFORMATION, NOR CAN IT ASSUME LIABILITY IN death. TURNED TO THEIR ORIGINAL POSITION AND - CONNECTION WITH ITS USE. PROPERLY FASTENED. NOTICE: Since the manufacturer has a policy of continuous product improvement, Page G-588-305 it reserves the right to change specifications and design without notice. Dwg.No.21X661049 P01 ®American Standard Inc. 1992 CM 1/30/92 INDOOR FAN PERFORMANCES HIGH SPEED LOW SPEED AIRFLOW Press. Pwr. BHP Press. Pwr. BHP ID CFM In. W.G. Watts In.W.G. Watts 1600 0.92 778 .652 0.70 684 .498 (FACTORY SETTING 1650 0.87 793 .664 0.64 703 .499 AT LOW SPEED. 1700 0.83 809 .676 0.57 724 .497 ®WETCOIL,NO FILTER. 1750 0.78 825 .688 0.49 748 .488 1800 0.73 841 .701 0.39 776 .468 ®WATER BLOW-OFF LIMIT 1850 0.68 857 .714 0.30 816 .441 1900 0.63 874 .727 0.22 866 .405 1950 0.57 891 .741 2000 0.51 909 .756 2050 0.45 927 .772 1 2100 0.38 946 .788 2150 0.31 966 .806 © 2200 0.24 987 .825 From Dwg.21A730904 Rev. 1 • . • : 2 • Sequence of Operations Operation of the unit heating or cooling cycles is controlled by the setting A second retry is then attempted. If this attempt at ignition is . unsuof the system switch on the room thermostat.Once the system switch is ccessful, a third retry will be attempted after a prepurge placed either in the "HEAT" or "COOL" position, unit operation is period.If this third attempt at ignition is unsuccessful,the con- automatic.A fan switch on the thermostat also provides for continuous trol will lock out. operation of the evaporator fan when desired. The fan switch "ON" The temperature limit switch(TCO)protects against overheat- position provides continuous operation while the"AUTO"position pro- ing if the indoor motor(IDM)fails to operate.Also,a fusible link vides operation during the heating or cooling cycles. (FS)protects against flame rollout due to flue blockage.These switches will interrupt the operation of the unit by de-energizing HEATING CYCLE the ignition control module(IGM)if overheating occurs. The temperature limit switch(TCO)is located in the gas corn- On call for heat by the room thermostat,the heating relay(H)is energized. partment.This automatic reset device protects against exces- The combustion fan motor(CFM)operates and as the motor reaches full sive leaving air temperature. speed,the pressure switch(PS)is closed.This completes the circuit to The fusible link(FS)is located in the gas compartment near the the ignition control module(IGN)through the normally closed tempera- burners.This is a single use device designed to protect against ture limit switch(TCO)and the fusible link(FS).After a prepurge of ap- any form of flame rollout. proximately 30 seconds the gas valve(GV)and the igniter probe(IP)are energized and the burners are lit. COOLING CYCLE The flame detector(FD)at the burner senses the presence of flame and With the room thermostat system switch in the "COOLING" de-energizes the igniter probe 2 seconds after flame is sensed.A fan position and the fan switch in the'AUTO"position,the corn switch(FS)causes approximately 30 second delay in energizing and de- pressor contactor(CC)and the indoor fan relay(F)are ener- energizing the indoor fan motor(IDM)by means of the indoor fan relay. gized. The energized compressor contactor(CC)completes the cir- SAFETY SEQUENCES AND LIMIT CONTROLS cuit to the compressor (CPR) and a secondary circuit to the During the main burner operation,if gas is interrupted or discontinued,the outdoor fan motor(ODM).If the compressor safety controls are gas valve (GV) is de-energized instantly. The ignition control module closed,the compressor(CPR)will operate with the outdoor fan (IGN)then enters the retry mode. motor (ODM). The indoor fan motor(IDM) will operate. The thermostat will continue to cycle the compressor and fans to The retry mode allows the control (IGN) to purge for 90 seconds. maintain the desired temperature. Following this time period the valve is energized and the spark is started. With the thermostat fan switch in the"ON"position,the indoor If the flame is not sensed by the flame detector(FD)within 8 seconds,the fan motor(IDM)will continue to run regardless of compressor .valve is de-energized and the spark is stopped. and condenser fan operation. SUPERHEAT CHARGING CHART CHART BASED ON 400 CFMJTON INDOOR AIR FLOW AND 50%RELATIVE HUMIDITY. v-INDOOR DRY BULB TEMPERATURE NOTES: "111201111:11:1111111" mm 11111111""' ■■■■■■■■n 1. MEASURE INDOOR DRY BULB '` ■■■��■■■ ■anlaaln TEMPERATURE. IIHIh'I.N1;1111 IHUIIHW11H11H11HlIHHIIHIIIHI 45 •�a■1unu�u111 ■■■a■■■■■■1■■■■■■uu■■■■■■ 2. MEASURE OUTDOOR DRY BULB ■11■n■a�1■1 � ■1� nn■11nn1■■m■m1■1ni11n1 11■11■■MMUSWO ffm1M.EMEMUMMEQNEUE �111amlO IIIENEENIFIEEEEEEIRESIESES 111■11■■1■1Oml TEMPERATURE. 40EM RuW■u■w-�Ru■ URT:1uu nu■nn■ml 3. MEASURE SUCTION PRESSURE n1■111\'Q■1 ■►.\il■0\■i_ 'tel■■■■■i■■1■O■1 ■ na..u0■ ■11■■a■3cuu■■:pm_Q■1nn■■a.... ■nao ■®a■ni■u■■ID AT PRESSURE TAP ON OUTDOOR EREEEMEEREEEEER u■'�Eaau■oC\W■■■■E.tln■■MENEZMln :, ■1u■■w.a.a UNIT. 35 HIJI ,I i i 1 1 � SIL = �IiII1 4 I ��IHm 4. MEASURE SUCTION TEMPERA- ■n■ ` 11� e- B�H� TORE NEAR PRESSURE TAP ON npl�■i■imUi`s■li■a�lic.■1■■nim•szilnnvrn lbi;;a1nn111i■nn LL 30■� i�41■auii1all m iV ■!�W 4.11 s•Un aeuilomill OUTDOOR UNIT • n■ • ■ml�■n■■■C\n ■ ■■11n■AQ1l■ �n■nn F- 1.a■■n\m■■■■sdn■■REMICR ■■ r\■■o■■unuiilsrn■■ 5. DETERMINE DEGREES SUPER- 251111®Ils11111 ilum1 rmilmermi. hiHimmrHH�111118 PRESSURE CHARTHEAT FROM EMP ERATURE OR LOW SIDE 1111HIIIIIaHIIIh�i111i11`LI1111HIi:11H111H1 iHNHIHIH MANIFOLD GAUGE. a O■11n■■n1■ON•WI■1.1 C ►'.a1■■■u■■nul�QII■n1 20�i1=■n■ZiIMWO.\ d■1%�1��1�ni ■1t■�A■0�1►\O■■11ZMUI11�I (0 mu1=1n■nlow=o 6. FIND THE INTERSECTION WHERE Nu nn■11"Vnun l•nrmn.uo r�■no.a�mmnou THE OUTDOOR TEMPERATURE ■n1 ■l11 ■►a111■11■■Ca .n 11n111m 15 u1■1■un_m1■im u■ �u ni Enumm■mg. U�` AND INDOOR TEMPERATURE mu■1nm■■■■.....■ .�■■u■W\�■■■■n■■■��nnm■tan■lila.. MEET AND READ DEGREES SU- 10 1111101111111111111 �»�ilii� �""�n ��; �� M RHEAT. IF UNIT SUPERHEAT IS 1� `,■� ■t■] I�1' MORE THAN 5° ABOVE CHART ■EEEERR1Aa■■ 11x1■■ ENEMII1■A•■■■■■■1nl■a a=■1■■ 1■1■ VALUE, ADD R-22 UNTIL WITHIN ' limn' > 5°. IF UNIT SUPERHEAT IS MORE 5 ' l �,,: I'CHARGE ;,, , �_ ' �� i'� � THAN 5° BELOW CHART VALUE, aa1 DO NOT ADD CHARGE fF LIMIT LINE f Ns - ■■■1111!.1 REMOVE R-22 UNTIL WITHIN 5'. S POINT FALLS BELOW THIS LINE ■11\'a111nn...■ncamnnl■l0'� ■ n■1i■■■■■■■1�■■1■■■■■111■\. ■ 5■lunl■ua u1118111a85 V1■■ ■ anminn 7. IF SUPERHEAT IS BELOW THE 5° 55 60 65 70 75 80 85 90 95 100 105 Ito 115 LIMIT LINE,DO NOT ADD R-22. OUTDOOR TEMPERATURE°F From Dwg.No.21Bi23511 3 PERFORMANCE CURVES - PACKAGE COOLING YCC060F-M-A - • 400 INDOOR ENTERING , O WET BULB F _ ` (/1 350- UPPER CURVE I S 71°F , , � LOWER CURVE I S 59°F, r'� 250 %0 ', w200 ✓�� •! I `"" O 150 � . . 100 1H ' I H F 65 75 85 95 105 115 OUTDOOR TEMPERATURE ( °F) 100 INDOOR ENTERING WET BULB F FROM TOP DOWN ! _.95 -H CURVES ARE: 71°F, 67°F, 63°F, 59°F �� • 0 90 ��-, � Cl- 85 _ , LAJ 80 ice^ . w 75 i cl- 70 z ---^ o -0.-' - 65 1 i . I- - . o . 60F 55 1 . ' 50 , , 65 75 85 95 105 115 OUTDOOR TEMPERATURE ( °F ) NOTE:The following is high speed data only. COOLING PERFORMANCE CAN BE CHECKED WHEN THE OUTDOOR TEMP.IS ABOVE 75'. TO CHECK THE COOLING PERFORMANCE,ALLOW PRESSURES TO STABILIZE AND MEASURE INDOOR WET BULB TEMP.—OUTDOOR TEMP.—HEAD AND SUCTION PRESSURE.LOCATE OUTDOOR TEMP.a')LOCATE INDOOR WET BULB®FIND INTERSECTION OF OD TEMP.&ID W.B.3 READ HEAD OR SUCTION PRESSURE IN LEFT HAND COLUMN T. III ACTUAL HEAD PRESSURE SHOULD BE±10 PSIG OF CHART SUCTION PRESSURE SHOULD BE±3 PSIG OF CHART . From Dwg.No.21C730396 4 WIRING DIAGRAM • INDOOR SECTION- CONTROL BOX - HEATER SECTION OUTDOOR SECTION r IGN CFM < a_ ,_, I IGN•o•n•l L ODM . , a MV FPTH u • • • )c— 1 (G81 m 1 j w Y rr 1C 0_,w CN-54 • CN-4 PS a_Z j mmm Zmm CN-16 ceL'm <<< ¢}w Y o Y �rn rNO 0-m aM 5i m - _ o - w re-- 7A(OR) FTBA w N mm PURPLE - CI • 20A(RDI m 3C(RD) BLACK C1 — 35BIRD1'' CPR 2B(BK1 47A(BKI PURPLE 48810K) o o_'a w 3BIRD) •• • BROWN RED ID CN-14 CN-15 C -0:cecc 4BA(BK) S • R w m n m YELLOW • • BROWN • ES Q • r 0. - o 35C(RD) •IFAN7 • WHITE CN-2 2D(BK) 0 ce - n ico FLS _ o i ORANGE CN-7 m U - 37AlBRiIL NIi1' - ( RED CM-1 1D(RD) rrIF �rri 38AIBR)-� aN "�38A(BR) TNS1 BLACK/RD CN-3 35A I RD IIII -- J F L '35B(RDI 10 © III , BLACK/BL LN_6 o �, m 39A(BR1— L 368(BL) m i �36C(BL1 °T5 0 4. (GR) n n a 36J(BL) a2A(BR) 1 -- 36D,F(BLI 1A,B.C,D(RD) • 3A,B,C(RD) _ 1 BROY.+'1 • 2A,B,C.D(BK) • • • 4A(BK) BLACK 44A(YLl 45A(BK) --4 (GRIFD (CR) 1 I w 0 0 C_' Y J -, Z Ce CO CO 5- m < < < < < m o �IP N - n * CO I =U RWGYB INSET B Q5 DEVICE DESCRIPTION LINE F T"?4 CC COMPRESSOR CONTACTOR COIL 45 PURPLE CF1 OUTDOOR FAN CAPACITOR 20 1 20A(RD) B 1 CF2 INDOOR MOTOR CAPACITOR 22 I BLACK ICN CONNECTOR OR WIRE NUT CFM COMBUSTION FAN MOTOR 27 RED p ABBR COLOR ABBR COLOR 28(BK) _ BK BLACK PR PURPLE BL BLUE RD REO BR BROWN WH_WHITE GR GREEN YL YELLOW F INDOOR FAN RELAY COIL 43 NOTES: OR ORANGE FD FLAME DETECTOR 39 CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT. FL FUSEABLE LINK 35 SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER FLS FAN LIMIT SWITCH IFS &TCOI FTB FAN TERMINAL BLOCK 23.25 CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY BE NEC FS FAN SWITCH 42 CLASS 2 AND MUST BE A MIN. OF 18 A.W.G. GV GAS VALVE 35 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) H HEATING RELAY 40 BETWEEN "B" AND „R„ OF 0.5 AMPS. 24 VAC IS IDM INDOOR FAN MOTOR 23 AVAILABLE IN THE COOLING MODE ONLY. IGN IGNITION CONTROL MODULE 34-35 Q FOR 208 VOLT OPERATION MAKE THE FOLLOWING WIRING IOL INTERNAL OVERLOAD CHANGES: IP IGNITOR PROBE 37 A: AT TNS1 MOVE 1DIRD) FROM RED WIRE AND CONNECT ODM OUTDOOR FAN MOTOR 19 TO ORANGE WIRE. THE RED WIRE MUST BE RE- PS PRESSURE SNITCH 35 TERMINATED TO AVOID ACCIDENTLY SHORTING. TOO TEMPERATURE LIMIT SWITCH 35 B: AT IDM MOVE 2DA(RO) LEAD FORM FTBA-B TO YELLOW I TNS1 CONTROL POWER TRANSFORMER 32 illLEAD AT CF2. 4. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105' C. • <23INDOOR BLOWER MOTOR CONNECTIONS SHOWN ARE FOR THE YC•024F1,-036F1, -04211, AND -06011 UNITS. FOR INDOOR BLOWER MOTOR CONNECTIONS FOR THE YC•018F1,-030F1, AND -048F1 UNITS SEE INSETS A From Dwg. No. 21D756911PO4 AND B. 5 vi CI . Z m CAUTION-NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150 VOLTS TO ®WARN I NG n GROUNDOD IDN: NE CONVIENT PAS POUR HAZARDOUS VOLTAGE! 5 LESDISCONNECT ALL ELECTRIC POWER INSTALLATIONS DE PLUS DE 150V. A TERRE. BEFORE SERVICING. FAILURE TO DISCONNECT POWER SUPPLY G BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH DUE TO — UNI T FACTORY W I RED ELECTRICAL. SHOCK. INSET A 2_ FOR 230V ®AVERT I SSEMENT YELLOW U 73 SEE WIRING DIAGRAM NOTES FOR VOLTAGE HASARDEUX! 1IC� 3 REQUIRED WIRING CHANGES WHEN OECONNE9TEZ TOUS LES INTERRUPTEURS W�? BROWN D INSTALLED ON A 208V POWER SUPPPLY. AVANT D EFFECTUER L'ENTRETIEN. 20A(RD) —B ���"' PURPLE IDM- E 4 - FAUTE DE DECONECTER LA SOURCE I • ELECTRIOUE AVANT D'EFFECTUERC BLACK IOL 5 __ POWER SUPPLY PER LOCAL CODES L'ENTRAINER DES BLFSSURES CORPORELLES HI 0-C SEE NAMEPLATE FOR LINE VOLTAGE. SEVERES DU LA MORT PAR ELECTROCUTION. 2BIRK) D RED &IMPORTANT LOW B 7 -- A USE COPPER CONDUCTORS ONLY B- TO PREVENT EQUIPMENT DAMAGE. UNIT TERMINALS ARE NO) DESIGNED - 9 - TO ACCEPT ANY OTHER WIRING. 10-_ (� ,� r---1 1, i t I • 12 -- 2 ami - �_ . 13— < A.e /77 2A,R,C.DIBK) CC-2 BLACN 15- ♦ .. -__� - ... 3CIRD) CR 7AIOR)o CPR 16- CC-1 IOL 17- •--__ )n,H,C.17(RDlp+l 3A,C1RD) 3AIR0) R 18-- ..-.- __-..... -__-- --- BLACK s 19 - 38(RDI 3 —__ 381 RD 1 PURPLE )p__. 7 • 22— CF1 BROWN2 21 — a YELLOW 22- F Q �1/o-_.BROWN - 18(ROI �.Ilo 2CAIR0) 20AIRD) 7-5 1 PURPLE IDM 23 • 24- • 28(8K) 1_ 3 28IBKI H O c BLACK 101 25 LOW O-D RED 26-- , LC_LI__;,_H13 21A(RDI__- -_ F 261A(RD)CN-4 RED • 27-- 1 3 CN-16 PURPLE CFM 28--- • 2CIBK1 _ 2CIBKICN-5 BLACK " / 29- 2D(8K) C 12 WHITE COM • • 30— I CN-7• ORANGE 2OHv. I - 31— •IDIRD) CN-1 RED 230V. Cil 32 1..,.-., TNS 1 • • • , • • • (CR) /17 33- - 35AI RO) CN-3 BLACK/RD _(ti,"7� BLACK/BL 36D,C(BL) 24 V. 34 CN-6 ` C PS 37AIRRITCO FL GV 35-_ _ N__,0 AIBR) 39A1BR 1 ..__ 39AIDR).TH Mv• 47A(:RI ) _LIN 36— m ._ P m FD 454181(1 •FION BROWN 3 RED 2 37_. 2 _ v1-4.-_._ LA y (CR 1 •CND ION.ORANGE • • I P 38— n n 7� COM • `7,7 3n • 363(DLI 9-- _.36EIBLI 36EIBLI, II 40— --- —_- _. 4181861 flo36F E(BL)__ H-26 41— I 41AIBR1 41A13R! I 35BIRDICN-14 35CIRD1 35C(RDI --�. -- H 42-• I ) J -- -.. p Kl CN.15486(BK)4:01-1. n o36C,OIBU 43— I o OOL -- I li 474.(131() UU F-23 ii 474.(131(1 44— T RH...ol..o OFF HEAT I I L 1 HEAT wt F-3 CC 45— ■■■•,C ) 'ONIFAN1 1 ,p __44AIYL1 44A1YLI op,. 36D,F(BLI CC-15, 46— I ) • •• •AUTO G ( _1 17 47— it°NEA7 1 48— I Q 36BIBLI I COOL COOL 1J _ ..... 49 -- • -FF �` Yi -- I 50 HEM COOL.2 51— Y2 v TYPICAL ROOM THERMOSTAT Q DEVICE DESCRIPTION LINE CC COMPRESSOR CONTACTOR COIL 45 CFI OUTDOOR FAN CAPACITOR 20 CF2 INDOOR MOTOR CAPACITOR 22 CN CONNECTOR OR WIRE NUT CFM COMBUSTION FAN MOTOR 27 CPR COMPRESSOR 15 CR COMPRESSOR RUN CAPACITOR 15 F INDOOR FAN RELAY COIL 43 FO FLAME DETECTOR 36 FL FUSEABLE LINK 35 I T _FLS FAN LIMIT SWITCH (FS & TCO) 3 FTB FAN TERMINAL BLOCK 23,25 3 FS FAN SWITCH 42_ E GV GAS VALVE 35 co H HEATING RELAY 40 Z _-_ IDM INDOOR FAN MOTOR 23 P ICN IGNITION CONTROL MODULE 34-38 • nt IOL INTERNAL OVERLOAD p IP IGNITOR PROBE 37 .4 ODM OUTDOOR FAN MOTOR 19 • m PS PRESSURE SWITCH 35 TCO TEMPERATURE LIMIT SWITCH 35 "p TNS1 CONTROL POWER TRANSFORMER 32 0 A • REFRIGERANT CIRCUIT ---_ OUTDOOR • SECTION MIL 1 ^ INDOOR ^ SEC"ION 1 Su.ION s ff DI4C sue:oo— :Dm CAP T:f From Dwg.No.21C730676 ,'401S DITECTIp1 t�ralcswwr vLw COOLING REFRIGERANT CYCLE TROUBLESHOOTING CHART—WHAT TO CHECK • SYSTEM FAULTS ``� yg ' iAf`$ 9Cti . ` 140 0 %41%Cr° %%t%IAN tis C'y "tV4t. AE FRIGERANTCIRCUT _ Liquid Pressure Too High P S P S S Liquid Pressure Too low S P S S S Suction Pressure Too High S P P S P Suction Pressure Too low S S P S Liquid Retrig.Floodback(TlN System) S S liquid Retrig.Floodback(Capillary Tube System) P SS SP I.D.Cog Frosting P P S Compressor Runs Inadequate a No Cooling S P P S S P S ELECTRICAL r — Compressor&O.D.Fan Do Not Start P P SPPP Compressor Will Not Start But OD.Fan Runs P SP P P S O.D.Fan Won't Stan P P Compressor Hums But Wont Start P PPPS S Compressor Cydes on IOL PSPPPS P S P S S S S S • I.D.Bower Wont Start P S S P P P Primary Carps S Secondary Cases Cs American standard Inc.,1991 Technical Literature Printed in U.S.A. 8 . , TRANE YCDO75SQ216.04 Tag: SUBMITTAL All dimensions are in inches Standard Efficiency TOP PANEL 61/4 EVAPORATOR SECT Ton ACCESS PANEL CONDENSER FAN Packaged 5 115/1 6" Gas/Electric 1 _ Downflow f (�l(r«< _Win►►.-- YCD075C 1/2 NPT ', GAS j; CONNECTION \ ` / 41 13/16" j CONDENSER COIL r / � �,.s. 2" DIA. HOLE 1 7 8 (UNIT POWER WIRES) 87 1/16" �� / 2 3/8" r CONTROL & COMPRESSOR /' / 7/8" DIA. HOLE ACCESS PANEL 49 9/16" (UNIT CONTROL WIRES) 8 5/16" 6 3/32" /4 6 171 5' { 42'� 1 13/16" 'I, 81 17q„ CLEARANCE 36" %"1',„, CLEARANCE 18" HORIZONTAL 1 13/16" gE�J�N 51>.*. 1r 36" DOWNFLOW 14 '� 6�6 ROOF ,„,TYPICAL ROOF OPENING /* 14" OPENING , 81 5/8" Y ' 2 N�l 0 `•�,` 46 3/8 CLEARANCE 48 �� CLEARANCE 36" 81 5/g 2" 2' 46 3/8 Table 1 Unit Wiring Unit Minimum Circuit Maximum Fuse Size or Unit Operating Ampacity Maximum Circuit Breaker' Model No. Voltage Range (Standard/Oversize) (Standard/Oversize) YCD075C3 187-253 36.6/39.5 50/60 YCD075C4 414-506 17.7/18.9 25/25 YCD075CW 517-633 14.2/14.7 20/20 Note: 1.HACR type circuit breakers per NEC. 2.MCA values do not include Power Exhaust accessory. Table 2 Electrical Characteristics—Power Exhaust Accessory Accessory Amps Accessory Operating Model Number Voltage Phase HP RPM FLA LRA BAYPWRX013A 208-230 1 3/4 1100 6.6 13.5 BAYPWRX015A 460 1 3/4 1100 3.1 6.4 BAYPWRX014A 575 1 3/4 1100 2.4 5.2 Table 3 Accessory Net Weights(lbs)' Oversized All LPG Economizer Outside Air Damper Roof Motor Power Zone Conversion Net Manual Motorized Curb Adder Exhaust Sensors Kit 40 32 35 82 5 65 1 5 Notes: 1. Net weight should be added to unit weight when ordering tactory installed accessories. Table 4 General Data 61%Ton Downflow Units • YCD075C3,C4,CW Cooling Performance, Gross Cooling Capacity 75,000 EER, 9.00 Nominal CFM/ARI Rated CFM 2,500/2,188 ARI Net Cooling Capacity 72,000 System Power(KW) 8.00 Heating Performance' Heating Models Low High Heating Input(Btuh) 120,000 205,000 1st Stage(2 Stage Only) — 150,000 Heating Output(Btuh) 97,000 166,000 1st Stage(2 Stage Only) — 122,000 AFUE%4 81 81 Steady State Efficiency(%) 81 81 No.Burners 1 No.Stages 1 2 Gas Connection Pipe Size(in.) 1/2 Compressor No.!Type 1/Climatuff® Sound Rating(BELS) 8.8 Outdoor Coil—Type Hi-Performance Tube Size(in.)O.D. .375 Face Area(sq ft) 11.32 Rows/FPI 2/16 Indoor Coil—Type Hi-Performance Tube Size(in.) .375 Face Area(sq ft) 7.00 Rows/FPI 2/15 Refrigerant Control Short Orifice Drain Connection No./Size(in.) 1/3/4"PVC Outdoor Fan—Type Propeller No.Used/Diameter(in.) 1/24 Drive Type/No.Speeds Direct/1 CFM 4,870 No.Motors/HP 1/.50 Motor RPM 1075 Indoor Fan—Type FC Centrifugal No.Used 1 Diameter x Width(in.) 1/12 x 9 Drive Type/No.Speeds Belt/1 No.Motors 1 Motor HP(Standard/Oversized) 1.0/2.0 • Motor RPM(Standard/Oversized) 1725/1725 Motor Frame Size(Standard/Oversized) 56/56 Filters—Type/Furnished? Throwaway/Yes (No.)Size Recommended(in.) (3)16 x 25 x 1 Refrigerant Charge(Lbs of R-22)6 9.1 NOTES: 1. Cooling Performance is rated at 95°F ambient,80°F entering dry bulb,67°F entering wet bulb.Gross capacity does not include the effect of fan motor heat.ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to±20%of nominal cfm. Rated in accordance with ARI Standard 210. 2. EER and SEER is rated at ARI conditions and in accordance with DOE test procedures. 3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2,000 feet. For elevations above 2.000 feet, ratings should be reduced at the rate of 4%for each 1,000 feet above sea level. 4. AFUE and Steady State Efficiency are rated in accordance with DOE test procedures. 5. Sound is rated in accordance with ARI Standard 270. 6. Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. '..,'@:-.'- '''''' UL (4-, • ,,i,2 All dimensions Are in Inches . 11/2 „ 334 „ 1 41 1� „ 11//7-.' 167,6 '' 1/2 r ,J1355�„ 41 4 O� Fresh Air Hood I � (Manual) 1 i I LIIIIWp...._.._........ 19 1/" Lc ' Q ., '•I 1 11 1�`, STANDARD END PANEL OF UNIT ECONOMIZER HOOD '141/2" 4 CENTER OF GRAVITY . - LENGTH A A r---7 B } CENTER OF GRAVITY r l 1 WIDTH R + S E lJ 1 T 42 7/8" P 35 1/4" U P R L N Y L L I L --J 1 3 3/8" D o 1 [— —c ► 22 1/2"- --� CENTER OF GRAVITY r7 � M LnN 3/4" PVC CONDENSATE LOCATION Table 5 Maximum Unit and Corner Weights(Lbs)and Center of Gravity Dimensions(In.) Maximum Weights(Lbs)2 Corner Weights(Lbs)1 Center of Gravity „ Shipping Net A B C D Length Width 938 750 238 192 144 176 39 21 Note: 1. Corner weights are given for information only. 2.Weights are approximate. 3 Table 6 Gross Cooling Capacities(MBH) Ambient Temperature 85 95 105 115 Enter. Dry Entering Wet Bulb CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (F) MBH SHC MBH SHC MBA-SAC MBP-SRC MBH SRC Vf81-S7C MBH SNI, MBH QAC MBH SHC, MBH SHC MOH SHC, MBH SHC, 75 70.2 55.7 77.3 45.8 81.3 29.6 65.2 53.0 73.6 43.9 78.7 28.0 60.0 50.2 68.9 41.6 75.2 26.0 54.5 47.3 63.0 38.9 70.8 24.0 80 70.8 66.1 77.7 53.1 81.9 40.2 66.1 63.4 73.9 51.4 79.3 38.4 61.1 60.7 69.1 49.0 75.6 36.3 55.9 55.9 63.3 46.2 71.0 34.1 2250 85 73.1 73.1 78.1 62.8 82.6 48.5 69.2 69.2 74.2 61.4 79.7 47.5 64.9 64.9 69.4 59.2 75.9 46.0 60.4 60.4 63.8 56.5 71.3 44.1 90 76.7 76.7 78.7 72.4 83.4 57.0 73.4 73.4 74.9 71.4 80.4 56.5 69.5 69.5 70.5 69.6 76.5 55.5 65.0 65.0 65.1 65.1 71.6 53.9 /2 /1.8 08.8 /8.3 44.0 81.8 29.8 00.0 00.0 /4./ 42.0 /0.3 20.3 61.0 03.2 /U.2 4U.0 /5.9 20.2 55.9 20.3 04.5 31.8 /1.5 24.3 80 72.6 70.1 78.7 55.1 82.5 41.5 68.0 67.5 75.0 53.7 79.9 39.7 62.8 62.8 70.4 51.6 76.3 37.7 58.2 58.2 64.7 48.9 71.8 35.5 2500 85 75.4 75.4 79.2 65.5 83.2 52.7 71.8 71.8 75.4 64.5 80.5 48.9 67.6 67.6 70.8 62.8 76.8 47.7 62.9 62.9 65.3 60.2 72.2 46.1 90 78.8 78.8 80.0 75.7 84.2 58.6 75.6 75.6 76.4 75.2 81.3 58.5 71.8 71.8 71.9 71.9 77.4 57.9 67.5 67.5 67.6 67.6 72.6 56.7 /5 /3.1 61.5 79.0 40.5 82.2 30.3 08.1 59.9 75.6 44.5 79.8 28.8 62.7 55.0 71.1 42.1 76.4 26.9 57.0 53.1 65.6 39.2 /2.1 24./ 80 74.1 73.7 79.5 56.9 83.0 42.8 69.4 69.4 75.9 55.9 80.4 41.0 64.9 64.9 71.3 54.1 76.9 39.0 60.1 60.1 65.8 51.5 72.5 36.8 2750 85 77.1 77.1 80.1 67.9 83.8 50.6 73.8 73.8 76.4 67.3 81.2 50.1 69.7 69.7 71.9 66.0 77.6 49.3 65.0 65.0 66.6 63.7 72.9 47.9 90 80.3 80.3 81.1 78.6 84.8 60.1 77.3 77.3 77.4 77.4 82.0 60.3 73.6 73.6 73.7 73.7 78.2 60.1 69.4 69.4 69.5 69.5 73.4 59.2 /5 /4.0 04.1 /9.b 4/.0 02.5 JU./ 00.3 b1.1 /02 40./ 80.1 29.2 03.9 26.6 1I.8 43.6 /0.5 21.2 26.1 25.5 bb.4 41.0 /2.0 20.1 80 75.0 75.0 80.2 58.4 83.3 44.0 71.3 71.3 76.7 57.8 80.9 42.3 66.8 66.8 72.1 56.3 77.4 40.3 61.9 61.9 66.6 53.9 72.9 37.7 3000 85 78.6 78.6 80.9 70.0 84.3 51.5 75.3 75.3 77.3 69.9 81.7 51.2 71.4 71.4 72.9 68.9 78.1 50.6 66.8 66.8 67.7 67.1 73.5 49.5 90 81.6 81.6 82.0 81.2 85.3 61.3 78.7 78.7 78.7 78.7 82.6 61.9 75.1 75.1 75.2 75.2 78.8 62.0 70.9 70.9 71.0 71.0 74.1 61.5 NOTES: 1. All capacities shown are gross and have not considered indoor fan heat.To obtain net cooling subtract indoor fan heat. 2. MBH=Total Gross Capacity 3. SHC=Sensible Heat Capacity Table 7 Electrical Characteristics-Evaporator Fan Motor-60 Cycle Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Unit Amps Amps Model No. No. Volts Phase HP FLA LRA No. Volts Phase HP FLA LRA 14 YCD075C3 1 208-230 3 1.00 5.9 32.2 1 208-230 3 2.00 8.8 53.0 • YCD075C4 1 460 3 1.00 3.2 16.1 1 460 3 2.00 4.4 26.5 • YCD075CW 1 575 3 1.00 2.6 13.2 1 575 3 2.00 3.1 18.4 Table 8 Electrical Characteristics-Compressor Motor and Condenser Motor-60 Cycle Compressor Motor Condenser Fan Motor Unit Amps Amps Model No. No. Volts Phase HP RPM RLA LRA No. Phase HP FLA LRA YCD075C3 1 208-230 3 6.25 3450 21.8 124.0 1 1 .50 3.4 10.8 YCD075C4 1 460 3 6.25 3450 9.7 64.0 1 1 .50 2.4 5.4 YCD075CW 1 575 3 6.25 3450 7.8 51.0 1 1 .50 1.8 4.1 Table 9 Combustion Blower Motor Data Heating Amps Heat Stages HP RPM Volts Phase FLA LRA Low 1 1/20 3350 208-230 1 0.4 1.00 High 1 1/20 3500 208-230 1 0.4 1.40 r 4 Table 10 Evaporator Fan Performance External Static Pressure(Inches of Water) Unit .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.25 1.50 Tons Model No. CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1 HP Standard Motor&Field Supplied Low Static Drive' 1 HP Standard Motor&Sheaves 2000 597 .39 646 .44 692 .50 739 .55 782 .60 825 .66 868 .71 907 .76 947 .81 986 .86 1082 .98 - - 614 YCD075C-L,H 2250 659 .53 705 .59 1745 .65 787 .72 829 .78 867 .84 905 .90 944 .96 982 1.02 1017 1.08 1104 1.22 1190 1.35 2500 723 .711 765 .78 802 .85 839 .92 877 .99 914 1.05 950 1.12 984 1.19 1019 1.26 1054 1.32 1134 1.49 1213 1.64 2750 789 .93 826 1.01 862 1.08 895 1.15 928 1.23 963 1.31 997 1.38 1030 1.45 1061 1.5311092 1.60 1171 1.79 1244 1.97 3000 855 1.19 887 1.27 922 1.36 953 1.44 983 1.52 1014 1.60 1046 1.68 1078 1.76 1108 1.85 1137 1.93 1209 2.13 - - 2 HP Oversized Motor&Sheaves Data includes pressure drop due to filters and wet coil. ', Fan motor heat(MBH)=3.53 x Fan Bhp. Trane's factory supplied motors,in commercial equipment,are definite purpose motors,specifically designed and tested to operate reliably and continuously at all cataloged conditions.Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure.Our product's warranty will not be affected. NOTES: 1. Field supplied Browning fan sheave AL74 and Belt A48 required. Table 11 Standard Motor and Sheave/Fan Speed(RPM) 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Open Open Open Open Open Closed 735 805 875 945 1015 1085 Table 12 Oversize Motor and Sheave/Fan Speed(RPM) 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Open Open Open Open Open Closed 840 910 980 1050 1120 1190 Table 13 Static Pressure Drops Through Accessories (Inches Water Column) Economizer With OA/RA Dampers' CFM Filters2 100%OA 100%RA 2500 0.07 0.13 0.02 3000 0.10 0.15 0.03 notes: 1. OA=Outside Air and RA=Return Air. 2. 1"filter. Table 14 Gas Fired Heating Capacities Air Temperature Unit Model No. Heating Input MBH Heating Output MBH Rise Range YCD075C-L 120 97 25-55 YCD075C-H' 205/150 166/122 35-65 NOTE: 1. Second Stage is total heating capacity. Second Stage/First Stage. ■ 5 M Specifications General Compressor ignition attempts, the entire heating The unit shall be dedicated downflow system shall be locked out until airflow. The operating range shall be Unit shall have a direct-drive hermetic, manually reset at the thermostat. Unit between 115°F and 0°F in cooling as reciprocating type compressor with shall be suitable for use with natural standard from the factory. Cooling centrifugal oil pump providing positive gas or propane (field installed kit)and performance shall be rated in accor lubrication to moving parts. Motor also comply with California require- dance with ARI testing procedures. shall be suction gas-cooled and shall ments for low NOx emissions. Unit Unit shall be factory assembled, have a voltage utilization range of plus shall have either a single stage low or internally wired,fully charged with R- or minus 10 percent of unit nameplate a two stage high heat option. 22 and 100%run tested to check voltage. Crankcase heater, internal Outdoor Fan cooling operation,fan and blower temperature and current-sensitive motor overloads shall be included for rotation and control sequence before maximum protection. Compressor The outdoor fan shall be direct-drive, leaving the factory. Wiring internal to statically and dynamically balanced, the unit shall be colored and num- shall have internal spring isolation and draw through in the vertical discharge sound muffling to minimize vibration The fan motor shall be bered for simplified identification. position. transmission and noise. Low pressure permanently lubricated and have built- Units shall be UL listed and labeled, switches shall be standard. p y classified in accordance to NSIZ21.47 in thermal overload protection. for gas fired central furnaces and UL Refrigerant Circuit Indoor Fan 1995/CAN/CSA No. 236-M90 for Central Cooling Air Conditioners. Refrigerant circuit shall have fixed Unit shall have a belt driven, FC, Canadian units shall be CSA certified. orifice expansion device, service centrifugal fan with adjustable motor Casing pressure port and refrigerant line filter sheave.. Motor shall be thermally drier factory-installed as standard. An protected. Optional oversized motor Unit casing shall be constructed of area shall be provided for replacement shall be available for high static zinc coated, heavy gauge, galvanized suction line driers. operations. steel. Exterior surfaces shall be Evaporator and Condenser Coils Controls cleaned, phosphatized and finished with a weather-resistant baked enamel Internally finned 3/8" copper tubes Unit shall be completely factory wired finish. Unit's surface shall be tested mechanically bonded to configuredwith necessary controls and contactor 500 hours in a salt spray test in aluminum plate fin shall be standard. pressure lugs or terminal block for compliance with ASTM 8117. Cabinet Coils shall be leak tested at the power wiring. Unit shall provide an construction shall allow for all mainte- factory to ensure the pressure external location for mounting fused nance on one side of the unit. Service integrity. The evaporator coil and disconnect device. Micro-processor panels shall have lifting handles and condenser coil shall be leak tested to controls shall be provided for all 24 shall be removed and reinstalled by 200 psig and pressure tested to 450 volt control functions. The resident removing only a single fastener on the psig. control algorithms shall make all units while providing a water and air Gas Heating Section heating, cooling and/or ventilating tight seal. The unit base pan shall decisions in response to electronic have no penetrations within the The heating section shall have a drum signals from sensors measuring perimeter of the curb other than the and tube heat exchanger design using indoor and outdoor temperatures. raised 1 1/8" high supply/return corrosion resistant steel components. The control algorithm maintains openings to provide an added water A forced combustion blower shall accurate temperature control, mini integrity precaution should the supply premixed fuel to a singlennizes drift from set point and provides condensate drain back up. The base burner ignited by a pilotless hot of the unit shall have provisions for surface ignition system. In order to better building comfort. A centralized forklift and crane liftin provide reliable operation, a negative Micro processor shall provide anti g pressure gas valve shall be used that short cycle timing to provide a higher Unit Toprequires blower operation to initiate level of machine protection. The top cover shall be one piece to gas flow. On an initial call for heat, prevent water leakage. the combustion blower shall purge the Filters heat exchanger 45 seconds before ignition. After three unsuccessful One inch,throwaway filters shall be standard. Filter rack can be converted to two inch capability. r 6 Ntec�nical Specifications Accessories Oversized Motor—Factory or field installed oversized motor shall be Roof Curb-Downflow—The roof available for high static application. curb shall be designed to mate with the downflow unit and provide support Coil Guards Coil guards shall be and a water tight installation when field installed for condenser coil installed properly. The roof curb protection. design shall allow field-fabricated Control Options rectangular supply/return ductwork to Trane Communication Interface be connected directly to the curb. (TCI)—Shall be provided to interface Curb design shall comply with NRCA with the Trane Integrated ComfortTM requirements. Curb shall ship System. knocked down for field assembly and include wood nailer strips. Zone Sensors—Shall be provided to interface with the Micro equipped Economizer-Downflow—This Voyagers and shall be available in accessory shall be either field or either manual, automatic program- factory installed. The assembly mable with night setback,with system includes: fully modulating 0-100 malfunction lights or remote sensor percent motor and dampers, baromet- options. ric relief, minimum position setting, preset linkage, wiring harness with Conventional Thermostat Interface plug, and fixed dry bulb control. The (CTI)—This field installed circuit barometric relief damper shall be board shall provide interface with standard with the downflow econo- electro-mechanical thermostats or mizer and shall provide a pressure automation systems. operated damper that shall be gravity Electronic Time Clock—This field closing and prohibit entrance of installed accessory allows up to 4 outside air during the equipment"off' units night set-back and unoccupied cycle. Solid state enthalpy and functions when using a standard (Dual differential enthalpy control shall be Setpoint) zone sensor module. factory supplied, field installed option. Differential Pressure Switches— iv Powered Exhaust—This optional This field installed option allows field installed accessory shall assist individual fan failure and dirty filter the barometric relief damper in the indication. The fan failure switch will economizer in relieving building disable all unit functions and "flash" pressurization. the Service LED on the zone sensor. Remote Potentiometer—The The dirty filter switch will light the minimum position setting of the Service LED on the zone sensor and economizer shall be adjusted with this will allow continued unit operation. accessory. Input/Output Expansion Accessory Manual Outside Air Damper—Field —This kit allows Integrated ComfortTM installed rain hood and screen shall Systems to read Supply Air Tempera- provide up to 25 percent outside air. ture, Return Air Temperature, Return Air Humidity, and direct indication of Motrized Outside Air Damper— fan failure without the use of an Manually set outdoor air dampers economizer or motorized outside air shall provide up to 50 percent outside accessory. air. Once set, outdoor air dampers shall open to set position when indoor fan starts. The damper shall close to the full closed position when indoor fan shuts down. a 7 • • • Since The Trane Company has a policy of continuous product improvement,it reserves the right to change Library Product Literature design and specification without notice. Product Section Unitary Technical Literature Printed in USA Product Packaged Gas/Electric Rooftop Model YCD075C—6Y<Ton The Trane Company LiteratureType Submittal 2701 VViIma Rudolph Blvd. Sequence 216.04 Clarksville,TN 37040 Date February 1994 http://www.trane.com File No. PL-UN-RT-YCD075-SQ-216.04 2/94 Supersedes YCD075-SQ-216.00 1 ©American Standard Inc. 1996