Report (9) Michael K. Brown, S.E. 5346 E. Branchwood Dr. Boise, ID 83716 208-850-7542 n 4 Mikebrown.se0gmail.com (T Andy Thomas 12 ` ( ) Stonebridge Homes0® IA- 4230 Galewood St., Suite 100 '"s Lc f Lake Oswego, OR 97035 Re: Tigard, OR Lateral Drawings: Strap Beam/Girder Truss to Wall Stonebridge Job Number: Engineer Job Number: Dear Andy: It's my understanding that straps were not added at the Girder Truss Beams to wall top plates. The following is the proposed correction: 1. In place of the ST6224 straps to be used at the Girder Truss to wall connections as called out in the plans and detail 7/S2, a TS22 (or greater) may be used. The twist strap has a capacity of 1215 pounds which is greater than the actual calculated values (maximum calculated value is at the lower floor, 918 pounds). If you have any questions, please do not hesitate to contact me. Sincerely, s j.4 • Michael K. Brown,'S.E.