Loading...
Report (6) GESCADE FRONMENTAL July 18,2016 r— RE,101:1 id. CD Cassie Eirelemeabl LLC Dr.Gene Davis AUG 29 2016 4346 NE 730 Avenue E-V Development LLC ParlErid,Oregon WM 10875 SWE 89Avenue CITY OF Tie 1" ARD Tigard,Oregon t3t W DNDIVIMN1 Mae MIR WV uslicaloniewittcom Rs: Pre-Damotilion Asbestos Containing Material Survey Residence 8735 SW Spruce Avenue Tigard,Oregon Cascade Environmental Project No.:07122016-02 Dear Dr.Davis: Cascade Environmental has prepared this Pre-Demolition Asbestos Containing Material (ACM) Survey report for the location referenced above. SCOPE OF WORK The purpose of this survey was to determine the presence of asbestos-containing material that may be impacted during the planned demolition activities at the location referenced above. Cascade Environmentafs Asbestos Hazard Emergency response Act(AHERA)Certified Asbestos Inspector,Mr. Robert Bums,conducted the survey on July 12,2016. ASBESTOS SURVEY Sampling and Analysts Cascade Environmentals asbestos survey was performed following the sampling protocols outlined under applicable United States Environmental Protection Agency (EPA) and Oregon Department of Emironnriental Quality(DEQ)regulations. Bulk samples of suspect ACMs were collected and sent to QuanTEM Laboratories for analysis using Polarized Light Microscopy(PLM) in accordance with EPA"Method for the Determination of Asbestos in Bulk Budding Materials" (EPA/600/R-931116, July 1993). QuanTEM Laboratories is located in Oklahoma City, Oklahoma, and is registered as an American Industrial Hygiene Association-accredied and National Voluntary Lab Accreditation Participation (#101959)- accredited laboratory. Routinely, the amount of asbestos is determined using a semi-quantitative technique, which involves calibrated visual area estimation. This quantitative method expresses the amount of asbestos as percent area and has a ink of detection of less than one percent When required, the amount of asbestos can be estimated using another semi-quantitative area estimation technique called point counting. In combination with gravimetric sample reduction procedures, point counting can achieve limits of less than one percent(<1%),when 400 points are counted and less than a tenth of a percent(<0.10%)if at least 1,000 points are counted. 1 2 Aa� Pie-Demolition Asbestos Containing al Sunre�r !1 , I QN ?ENTAL ACM's as defined by the EPA and the State of Oregon are materials with an asbestos concentration greater than one percent(>1%). However, the Occupational Safety and Health Administration (OSHA) regulates aft materials containing any detectable levels of asbestos. FINDINGS A summary of Cascade Environmentals asbestos inspection, including analytical results, sample numbers, material descriptions, and sample locations is provided in the following table. The analytical results and chain-of- custody documentation is included in Appendix A. ACM Sample Results Residence 8735 SW Spruce Avenue Tigard,Oregon Sample I Asbestos mus Material Sample Location Co twit SA-01 Wa$board/Joint Compound and Black Foam North Bathroom ND Insulation SA-02 12'x 12'Vinyl Floor Tile,Black and White Hallway ND Sheet Flooring,Off-white,Squares and SW Bathroom NO Flowers SA-04 Sheet Flo orilvzLight Gray Squares N.Bathroom ND SA-05 Ceiling Texture,Flat N.Bedroom ND SA-06 Blown in Insulation Attic ND SA-07 Roof Shingle&Tar Paper Roof ND ND=Non-Detect Sold—indicates at least one layer of the material sampled contains greater than one percent asbestos. ResuitslDiscuss The laboratory analytical results for this survey indicated that none of the samples collected during this survey contained greater than one percent asbestos and are not considered ACMs. Caution should be used during renovation activities as concealed building materials, that have not previously been analyzed for asbestos' may be encountered. If suspect ACMs located in accessible andior inaccessible areas of the facility are encountered during renovation activities, further sampling will be required to characterize those materials, prior to any disturbance. Other Miscellaneous Materials Cascade Environmental sampled all suspect asbestos containing materials identified in the areas to be impacted during demolition activities. Materials that are considered non-suspect asbestos containing materials may be included in the waste stream from the renovation activities. These materials may include wood, metal and fiberglass insulation. wear a Pre-Demation Asbestos C Material Survey , SCADE E; '1PONMENTAt LWTATIONS Reasonable effort was made by Cascade Environmental personnel to locate and sample suspect materials at the location. However,the existence of unique or concealed ACM, other hazardous materials or associated debris is a possbdity within any facility. If additional suspect ACM or other hazardous material is discovered during demolition it should be assumed to be hazardous until sampling and analysis proves otherwise. Cascade Environmental does not warrant, guarantee or profess to have the ability to locate or identify all hazardous materials within a facility. If you have any questions regarding this report or require further clarification,please do not hesitate to contact our office at(503)984 9737 or via email at bobacascadenviro.com. Sincerely, Cascade Environmental LLC Robert Burns Principal AHERA Inspector#IR-15-4095A Appendices: Appendix A—Laboratory Analytical Results&Chain-of-Custody Documentation APPENDIX A LABORATORY ANALYTICAL RESULTS &CHAIN-OF-CUSTODY DOCUMENTATION LABORATORIES 2033 HERITAGE PARK DR, OKLAHOMA CITY, OK 73120 1 . 8 0 0 . 8 2 2 . 1 6 5 0 Polarized Light Microscopy Asbestos Analysis Report QuanTEM Lab No. 266463 Client t'Ascn a Environmental LLC Account Number: C059 4346 NE 73rd Ave Portland,OR 97218 Date Received: 01/13/2016 Received By: Peyton Awbrey Date Analyzed: 07/16/2016 Project: 8735 SW Spruce Ave Analyzed By: Carter Cox Project Location: N/A Methodology: EPA/600/R-93/116 Project Number. NIA QuanTEM Client Color! Non-Asbestos Non Fibrous Sample ED Sande ID Composition Description Asbestos(%) Fiber(%) 001a Layered Black Asbestos Not Present NA Foam Insulation , 002 SA-02 Homogeneous Black Asbestos Not Present NA Vinyl Floor Tile CaCO3 003 SA-03 Layered Beige Asbestos Not Present Cellulose 25 Vinyl Sheet Vinyl Binder 003a Layered Yellow Asbestos Not Present NA Glue Mastic 004 SA-04 Layered White Asbestos Not Present Cellulose 20 Vinyl Sheet Vinyl Synthetic 5 Binder 004a Layered Tan Asbestos Not Present NA Glue Mastic 005 SA-05 Homogeneous White Asbestos Not Present NA CaCO3 Ceiling Texture Paint Unless otherwise noted.upon receipt the condition of the sample was acceptable for analysis. QuanTEM is a NVLAP accredited PLM laboratory(Lab Code:101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA//600/M4-82-020 and EPA/600IR-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full,without the written approval of the laboratory. Page 1 of 2 T., LABORATORIESTE 2033 HfitrTAGf PARK OR, OKLAHOMA Cry, OK 73120 1 . 8 0 0 . 8 2 2 . 1 6 5 0 Polarized Light Microscopy Asbestos Analysis Report QuanTEM Lab No. 266463 Client Cascade Ertifimenamud LLC Account Number: 0059 4346 NE 73rd Ave Portland,OR 97218 Date Received 07/13/2016 Received By: Peyton Awbrey Date Analyzed: 07/1612016 Project: 8735 SW Spruce Ave Analyzed By: Carter Cox Project Location: N/A Methodology: EPA/WO/R-93/116 Project Number. N/A QuanTEM Client Color I Noe-Asbestos Non amass Sample LD Sample ID Composkton Description Asbestos(%) Fier(9 6) 006 SA-06 Homogeneous Brown Asbestos Not Present Cellulose 100 Insulation 007 SA-07 Layered Gray Asbestos Not Present Glans Bret 20 Ta: Shingle QUIWIZ 007a Layered. Black Asbestos Not Present NA Tar Tar 007b Layered Black Asbestos Not Present Cellulose 60 Tar Tar Paper JY /vim g; Cox, 7/1612016 OReportuter A_ , ._.st of Unless otherwise noted,upon receipt the condition of the sample was acceptable for analysis. QuanTEM is a NVLAP accredited PLM laboratory(Lab Code:101959-0). This repot relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be repnodnced except in full,without the written approval of the laboratory, Page 2 of 2 CASCADE 1----LA "‘-`k.-LI U.';'-.-._:) PROJECT INFORMATION Turnaround: Same Day Next Day 06 day t tt: /Customer Cascade Environmental 4' Name: 3S S44) cif)rt.re, Ave Address:4346 NE 7 Avenue Collection Date: ./al .4;, e5c,,(149-k Address:Portland,Or 97218 Customer Number/P.O.: Phone:503.984.9737 Collection Address: Customer Contact Bob Burns Email:liobQcascadenviro.com Special Instructions: PLM(EPA 60WR 93/116,Please composite all WaObtard/Joint Compound samples (Sample lis S/4-i t 1 BULK SAMPLE LOCATION Page ) of Acc/ Sample Number Sample Material Sample Location Rej /" L i SA - Oo? l vrxi,1`'vrrl 7 ,4,, Ate Qc-(it 6 4-)Ink 41 Se -U 3 beet f h G , CT cok' t s (toe/Yt-(014eig('-) ✓` Pt- e A --a9 - k lc ., o ,ti , - t _ — r ( dt i U c: ( t # � r.i c. AA„..-:0-‘ ! rt',�c* t,,,i. Si _ 1)r . ?(� F�.,_-_.mss ‘,,_/_ei_4/ A4-c___-- -, r. . 5A - 01 . (.(0c4--,) A f , ,,../- j" c f„..)- r-_ `f'c Vit;I Sample collector is responsible for ensuring that all samples have been preserved and prepared to the appropriate and applicable methodology.If package has sustained damage during transit,notify collector and shipper.Turnaround time begins upon receipt of sample(s)by laboratory.Cardno AIC:will not be responsible for errors or omissions in calculations from inaccuracy of original data. CHAIN OF CUSTODY s t : : Date: Time: Received By: Date: Time: -.2.1145,...,6._. y T," e_