Plans MILBRANDT ARCHITECTS Bulletin
25 Central Way, Suite 210 • Kirkland, WA 98033
Tel: (425) 454-7130 • Fax: (425) 646-0945
Bulletin#: MA-12 Date: 8-17-2016 ATTACHMENTS: MA-12
Job Name: RIVER TERRACE Job No: 15-03
This bulletin is in response to a request from the City of Tigard regarding a 1/2"P.T. plywood
spacer strip being installed behind the deck ledger as shown on the attached MA-12 detail.
The attached MA-12 detail is approved by Milbrandt Architects to be used for the deck ledger
installation on the River Terrace project.
OF SCE COPY
CITY OF TIGARD
REVIEWED FOR CODE COMPLIANCE
Approved: [v)
OTC: [ I
Permit#: h- c-f' QC/ 000 67
Address: L,s1.3 70, S w S e i n e or
Suite#:
By: ' Date: 8 - )
REVISION
Distribution: From: David Burnett
Polygon Northwest
Attn: Chris Walther
Phone: (360)695-7700
EVISI N OFFICE COPY
i
BUILDING PAPER
0111 `' PRE-FLASHING, EXTEND 6"
gie
. ABOVE LEDGER, MIN.
METAL Z-FLASHING TYPE B
/� SEE DETAIL 19/15
SPACED DECKING
iiiii� iiiii� iiiiii ilii«
P.T. 2x JOISTS
- ]- SEE STRUC. FOR U
I CONNECTION DETAILS
-1 P.T. 2x LEDGER
�� I P.T. PLYWOOD FUR STRIPS
12" x 112"-2" AT EVERY LAG.
� TYPE A FLASHING
SEE DETAIL 19/15
4 i•, N PRE-FLASHING, EXTEND 2" BELOW LEDGER, MIN.
SIDING
BUILDING PAPER OR PRE-FLASHING;
EXTEND TO ABOVE DECK-TO-WALL FLASHING
DECK TO WALL FLASHING
SPACED DECKING
} 1-1/2" = 1'-o» SECTION
R317.1.1.1 Field treatment/ Field-cut ends, notches and
drilled holes of preservative-treated wood shall be treated in
the field in accordance with AWPA M4
PROJECT NAME: RIVER TERRACE ARCH. JOB NO.: 1503 BULLETIN
DATE: 08-16-16 SCALE: 1 1/2" = 1'-0" PAGE:
PREPARED BY: DAVID BURNETT ,REF. SHEETS: DETAILS MA-12
This bulletin is a stand-alone document. Referenced sheets posted at online plan center have NOT been updated typically.
t
C T ENGINEERING
1 N C 180 Nickerson St.
Suite 302
Seattle,WA 98109
(206)2854512(V)
(206)285-0618(F)
asolomon@ctengineering.com
BULLETIN
Date: August 17,2016 Number:CT-11 Project#: 15238
Project Name: River Terrace Attached: None
Subject: Deck Connection Detail(Spaced Decking)
Drawings Affected:
Description/Action:
This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River
Terrace' project located in Tigard, Oregon.
Based on our review of Bulletin MA-12 (Deck to Wall Flashing—Spaced Decking), this is an
acceptable deck connection detail provided the fasteners attaching the ledger to the structure have
the required penetration to the rim/blocking per the structural deck details.
4GIN ! �j
60 Cr
'44
ilivvREGoqi
' 22 ,\c'5<c��PlFS T. G0(`
08/17/2016
CALL WITH ANY QUESTIONS
Issued by: Arnold R. Solomon Date: Aug. 17,2016
Distribution:
Contact Information:
Chris Walther Polygon Northwest Company •
Angela Graiewski Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace\Bulletins\15238_2016.08.17 CT11 Deck Connection Detail(Spaced Decking).doc
Structural Engineers
/tL S T.-O/ L , OUvC7
(C-3 7Z St SziNz ./JIB
%II 4,
1-
1- A U
CI! G22hii
616
l rJ�, � "° ; r`s' Mifbrandt
�rc(� Itects.
�,.,,.. . .,....._________ ...: r-I I I Central Smte 211
If 1;�
,� KI4 11 E 4,4A
�� r R4543f_71 r.4215513=211
1111
IIM
MIIIIMININ
II II S9e7e'xwae77lhre�IstxAcael
—Iimimin 'Ism— Illm— 11 AUG c--,
�m L
-� KIRKLAN5558 WA
OF 00
IN
II_limmnimim nm
minnom ow
L
.. ...1111,ii
==III= DECKMINiMIMI
ZILI
—� DECK
MINIMS
nimism
IMIIM
iiimium
INIMEN
MIliMom
� IIIIIIIIII IIIIIIilllllll _ _ I l III II I DOCK .n _ _
-.mommi —FonLI
�iil iI�II IIIc I IIIIII�
,.
—guqi___________
i :?-4 .4,," li ,isi, i, r
(Ii r
4111%.,, N. \c,:, ,,.., 1 r, , ,r,.• o „.
. .,
,,
~ rJJ.� �yL,L____, , ,, II ....,,3 ;1!
s O
DROP DISTAND VCE
FOR SINGLE FAMILY DECK
SINGLE FAMILY DECK FOOTINGS AND VER CAL DROP DISTANCE FOR FOOTINGS
SIDE ELEVATION LENGTH of DECK;AZT REAR ELEVATION AND VERTICAL LENGTH OF DECK SINGLE FAMILY DECK SIDE ELEVATION - ”
7/4'=1'-0'
VARIES. 1/q•=1'-0• POSTS VARIES.
0
1/4,1,0• R a
m
IL
R e
0E.
W .E
0 R m'
LL. 25 0
6'-0'
_R
16'-0' d
I.9-0' g•_0• o
/ MANUF.RAILING SYSTEM (3)2x8 P.i.& O rte'
SURFACE OR FACE-ATTACHED (i)2x8 TRIM �Cirl� ��� RAIL POST _ n
O
o
78"x18"x70"FTG. ----------- --'------=-------------
: �-.; LJ. N a
® ® �` SUPPORT POST BELOW
/(2) & I ioniccati. it- A Ac,POST CAPppTosprorA '.v
Deck _
SPACED DECKING
III
4i+SDTTZZ _il
I • 11114--o°,,2
ECK ABOVE ___Z
)2x8 P.SI& mtv
(1)2x8TRIM m(3)2x8 P.T& ' (62x8 TRIM QoI Eo
P.i.1x6 V
P 2x LEDGER BRACE,TYP. c�DIAGONAL MI
(�)
SINGLE FAMILY DECK FLOOR PLAN SINGLE FAMILY DECK FRAMING PLANCU r
1/4'61'"0• 1/4•-1'0•
LL o
z
cu c
a) 0
C >.
0
Cl') a
Joh No_ 12-11
Sheet No_
Al
Sheet Order: A S D '°
I
/
'two x z �1p
-'yo S ,x$ � fi 6m� �' F-3A�NPoP PAS+,.,m4, ._.
; m �r?• Rmin ppl, vov,- mi