Loading...
Plans (2) BUP2016 - 00022 RECEIVET) ! " 20 2016 CITY OF 11GARDD1 • • BUILDING DIVISIONPLATINUM LEN NG SOLUTIONS cl�, TIGARD , OREGON PLATINUM LENDING SOLUTIONS TENANT DEFERRED SUBMITTALS N z N 7360 SW HUNZIKER RD, SUITE 100 MECHANICAL K TIGARD, OR 97223 ELECTRICAL w Uj Uj FIRE ALARM a a.. *DESIGN-BUILD CONTRACTOR SHALL COMPLETE, AS NECESSARY, REQUIRED w PORTIONS OF THE OREGON ENERGY COMPLIANCE FORMS a N N t0 N O co J W ROBINSON CONSTRUCTION CONTRACTOR Q DESCRIPTION OF WORK N N rn SCOPE OF WORK FOR SUITE 100 CONSISTS OF DEMOLISHING ALL INTERIOR WALLS AND DOORS AND 21360 NW AMBERWOOD DR CONTACT: RANDY ROBINSON LU -N' 3 REBUILDING NEW INTERIOR PARTITIONS, DOORS, CASEWORK, AND ADDING A DISHWASHER. SUITE 100 IS AN D_ EXISTING OFFICE, GROUP B OCCUPANCY, AND WILL CONTINUE TO BE USED AS OFFICES. ' HILLSBORO, OR 97124 00 TELEPHONE: 503.645.8531 W W UJI so FAX: 503.645.5357 <n P CL N D- 8 Of w 1004 OCCUPANT LOAD TABLE ARCH,!TECTU RT > H 0 O U+ w � ce _ U_ V04 � CIDA, INC. ARCHITECT NAME OCCUPANCY TYPE LDMNG AREA LOAD . V 0 % I- 1- 101 RECEPTION BUSINESS 100 270 3 0 . 102 OFFICE BUSINESS 100 87 1 .. 1 01.06.16 PRELIMINARY SET • • • 103 OFFICE BUSINESS 100 103 1 15895 SW 72ND AVE, SUITE 200 CONTACT: KELLY SANFORD 3 01.12.16 PERMIT SET • . • 104 OFFICE BUSINESS 100 161 2 15695 sw 72ND AVE SUITE 200 PORTLAND, OREGON 97224 PORTLAND, OR 97224 105 OFFICE BUSINESS 100 98 1 T E L : 5 0 3 . 2 2 6 . 1 2 8 5 106 BREAK ROOM ACCESSORY 100 181 2 F A X : 5 0 3 . 2 2 6 . 1 6 7 0 TELEPHONE: 503.226. 1285 W W W C I D A I N C C OM FAX: 503.226. 1670 107 OFFICE BUSINESS 100 120 1 TOTAL FOR OCCUPANT LOAD 900 9 BUILDING CODE SUMMARY Z GOVERNING CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE O OCCUPANCY TYPE: GROUP B SPRINKLERED VS. NON-SPRINKLERED: NON SPRINKLERED CONSTRUCTION TYPE: V-A PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN OCCUPANCIES AND LOCATIONS AS REQUIRED BY Q THE OREGON FIRE CODE AND THE FIRE MARSHALL O OCCUPANCY LAD (OSSC II WQL W GROSS FLOOR AREA (SUITE 100): 1057 SF / 100 = 11 OCCUPANT LOAD Ld o (SEE ALSO OCCUPANT LOAD TABLE ON THIS SHEET) co MEANS OF EGRESS ILLUMINATION W= 1006)_ (n N ILLUMINATION LEVEL (OSSC 1006.2): N MINIMUM 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL ILLUMINATION EMERGENCY POWER (OSSC 1006.3): Z r�l EMERGENCY POWER SHALL BE PROVIDED FOR A DURATION OF 90-MINUTES MINIMUM W cr 0) [ICE , AREAS REQUIRED TO BE ILLUMINATED BY EMERGENCY POWER x - CORRIDORS AND EXIT PASSAGEWAYS Uj z - INTERIOR EXIT AREA OF WORK - EXTERIOR LANDINGS DISCHARGE ELEMENTS � Y 0 EMERGENCY POWER FOR ILLUMINATION (OSSC 1006.3): N 0 SUITE OO INITIAL ILLUMINATION: __ _ __ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 1 FOOT-CANDLE AVERAGE W/ 0.1 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL Z Z ■ END OF EMERGENCY LIGHTING PERIOD: < w = Q _ ■ ,-, \ 0.6 FOOT-CANDLE AVERAGE W/ 0.06 FOOT-CANDLE MINIMUM AT ANY POINICJNI'ACQtLE�ISh W = 0 / ■ / REVIEWED FOR CODE COMPLIANCE sw DARTMOUTH UG OR. EXIT SIGNS (OSSC 1011)_ J 3 ~ ■ 1 �HOEN at SEE 5/T1.2 FOR LOCATIONS OF EXIT SIGNAGE Approve* 0 (D - OTC: _ O sw HURST w ILLUMINATION (OSSC 1011.3): / / ■ a SW NERMoso w r EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED Pcrmitwo Gt l'-2Qto a ry e. Q � / / ■ a7 ,� SW NKLIN S `� AJdreeei �i � ` )L ICJI,2I , ■ m O r x eLVELAND o EXIT ACCESS"TRAVEL DISTANCE (OSSC 1016): Suite#t I ck= •��r � ■ '� � � h a a � � g SW (TABLE 1016.2) g ■ O TREEC w „ NON—SPRINKLERED BUILDING, B OCCUPANCY: 200'-0" ALLOWED -" Sw oN sr. N 1 MAX DISTANCE = 98'-0" o HUry1110ER RD `° r a { EGRESS (TABLE 1021.2) / f / ■ sw cREslwLws� TOTAL OCCUPANTS: OCCUPANTS 1 EXIT REQUIRED CITY OF TIGARD H ■I : d� SW VARNS ST m 9} ° , 1 EXIT PROVIDED Approved by Planning ■ - 7h EGRESS WWTN REQUIRED (TABLE 1005.1) Date: i 7,17 /.� _- a i SUITE 203 PASSAGEWAY EGRESS WIDTH REQUIRED (9 x .2) = 1.8" Initials: N ■ m A g 5 SUITE 203 PASSAGEWAY EGRESS WIDTH PROVIDED = 36" J ■ J ^ O / SIN SANoeuRc ST _(OSSC 04APIM 11 AND ANSI CHAPTER 0- SW TECH CENTER D L SEE FLOOR PLANS FOR REQUIRED CLEARANCES AT DOORS, TOILET ROOMS (EXISTING) AND FIXTURES. JO T. ALL SIGNAGE GRAPHICS, LOCATION AND MOUNTING TO COMPLY WITH OSSC CHAPTER 11 CT. S "DMARK OFFICE COPY COVER SHEET ZONING CODE INFORMATION s NORTH NIMTH 1 EGRESS PLAN -- FIRST FLOOR 2 VICHTY MAP TAX MAP & LOT. 2S101DBO0103 CS1 m0 CS1 1/8"=1'-0" NO SCALE JOB NO. 150197.07 ZONING: C-P PROFESSIONAL COMMERCIAL ©2016 OOA P.O./MA ALL Wn RESD6'D1 p9 lJ �1 11y/^yII I X11 1 ud DEMO FLOOR PLAN LEGEND z (E) FRAMED WALL TO DEMO / 4'-0" PROVIDE METAL STUD BRACE AT i (E) FRAMED WALL TO REMAIN / / 6'-0" O.C. TO STRUCTURE ABOVE OR SOUND ATTENUATION BATT ABOVE � 2 / TOP OF WALL i o 1 SUSPENDED CEILING DEMO FLOOR PLAN KEYNOTES A FLUSH CONT. TOP TRACK- ATTACH TO CEILING GRID W/ 1" TYPE "S" DEMO (E) RELITE & FRAME, SALVAGE FOR RELOCATION IF FEASIBLE. SCREWS AT 2'-0" O.C. AND TO TOP �l PLATE OF PARTITION W/ (2) 1" 2 ii 2 DEMO (E) DOOR, HARDWARE AND FRAME, SALVAGE FOR RELOCATION. 2 DOOR TYPES TYPE 'S' SCREWS - TRIM PANEL AS n REQUIRED 1/4"=l'-O" w u w 2„ 2+, 2" 3,_8" 2„ �`--------- 'I I' FULL THICK SOUND ATTENUATION `D BATT z METAL STUD PARTITION PER PLAru N � V) Dip6R PER ~ D R PER n t= CD < V) 3 w3: w BASE ? SCHEDULE � z x SCHCH EDULE T z 2 � � BOTTOM TRACK TO FLOOR WITH w � a o < o ANCHORS AT 4'-0" O.C. (MAX) AND a- w DEMO FLOOR PLAN GENERAL NOTES AT CORNERS AND ENDS W 1. SEE SHEET T1.2 FOR ADDITIONAL CEILING DEMOLITION. FINISH FLOOR T `* cNo cN1 '- 2. DEMO ALL (E) FLOORING. PREP FOR NEW MATERIAL. SEE 9/T1.1 FOR o °w ADDITIONAL INFORMATION. 1 RECITE RECITE o 0 U) N T = TEMPERED GLASS NORTH 1 , DEMO FLOOR PLAN 3 RELITE TYPE rWA WALL TYPE - INTERIOR PARTITION ' T1.1 1/8" = 1'-O" T1.1 1/4"=l'-O" Tt1 3/4" = l'-0" 092900-03 WALL TYPES FLR PLAN KEYNOTES DOOR SCHEDULE OO -- -- I N T E R 1 • DOOR # DOOR HARDWARE OPENING WIDTH 9DOOR DOOR DOOR FRAME NOTES DOOR # �— NON RATED PARTITION WALL - 3-1/2", 25 1 ALIGN NEW WALL WITH EXISTING. TYPE GROUP x HEIGHT THMATERIAL FINISH MATERIAL • GFCI A A GAUGE METAL STUDS ® V-4" O.C. W/ ONE 2 RELOCATED RECEPTION DESK. PATCH AND REPAIR EXPOSED SURFACES 15895 SW 72ND AVE SUITE 200 LAYER 5/8" GYPSUM BOARD EACH SIDE TO AS NEEDED. MATCH (E) PL-3 AND PL-4 FINISHES. (E) 100-A (E) -- -- -- -- -- -- (E) 100-A PORTLAND, OREGON 97224 OFFICE THE UNDERSIDE OF THE CEILING. PROVIDE 3 RELOCATED (E) RELTTE, IF FEASIBLE. SEE 1/Tt.t, KEYNOTE 1. 102-A A 1 3'-0"x7'-0" 1 SC WD STAINED HMK == 102-A TEL : 5 0 3 . 2 2 8 . 1 2 8 5 T1 1 BREAK 107 0 SOUND ATTENUATION INSULATION. SEE DETAIL FAX : 5 0 3 . 2 2 8 . 1 6 7 0 ROOM 4/T1.1 103-A A 1 3'-0"x7'-0" 1 3/4- SC WD STAINED HMK 103-A W W W . C I D A I N O . C O M los 9'-8 1/2" -- 10 104-A A 1 3'-0"x7'-0" 1 3/4" SC WD STAINED HMK 104-A FEC 1 0 0 2 FLOOR PLAN GENERAL NOTES 105-A A 1 3'-0"x7'-0" 1 3/4" SC WD STAINED HMK -- 105-A 8 FO 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE VERIFIED BY 106-A A 2 3'-0"x7'-0" 1 3/4" SC WD STAINED HMK -- 106-A A I 3 so (E)10o—A FLOOR PLAN LEGEND __ 2 -N THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT / ENGINEER OF 107-A A 1 3'-0"x7'-0" 1 3/4" SC WD STAINED HMK 107-A OFFICE RECEPTION CORRIDOR ANY DISCREPANCIES PRIOR TO THE START OF WORK. O o 101 ROOM NAME & NUMBER FEC FIRE EXTINGUISHER CABINET GENERAL NOTES: O , i � 2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD UNLESS NOTED OTHERWISE. HAI�WPM SCHEME -11 i/2" 10'-0" 8'-11" 107-A DOOR NUMBER FOF FACE OF FINISH 3. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED AS REQUIRED ALL NEW DOORS TO MATCH EXISTING, SPECIES, STAIN, FINISH, & O BY APPLICABLE STANDARDS. TYPE 1 TYPE 2 HARDWARE. < < < (E) EXTERIOR WALL 1 RECITE TYPE 1 1/2 PAIR BUTTS 1 1/2 PAIR BUTTS THE OPENING FORCE SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS, A 1 0 IQ 1 0 1 (N) INTERIOR WALL 4. THE HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS, 8.5 LBS FOR EXTERIOR DOORS, AND THE MINIMUM FORCE REQUIRED TO DATA DISPENSERS, ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS CLOSE AND LATCH THE DOOR FOR FIRE DOORS. OSSC 1109.9.9 OFFICE OFFICE OFFICE {E) FRAMED WALL QUAD OUTLET AND OTHER OPERABLE EQUIPMENT SHALL BE WITHIN AT LEAST ONE OF THE 1 EA. OFFICE LOCKSET 1 EA. PASSAGE LOCKSET +60" REACH RANGES SPECIFIED IN SECTION 1109.2, AND NOT LESS THAN 36" ABOVE 104 TV los 102 THE FLOOR. ELECTRICAL AND COMMUNICATIONS SYSTEM RECEPTACLES ON WALLS ALL HARDWARE HALL COMPLY WITH THE REQUIREMENTS OF THE ADA. A FFnll� COPY MACHINE DUPLEX OUTLET SHALL BE MOUNTED NO LESS THAN 15" ABOVE THE FLOOR (1109.3.2). 1 SET SILENCERS 1 SET SILENCERS O A DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OFA O (E) EXISTING 5. PROVIDE OUTLETS PER PLAN. NO MORE THAN SIX 110 OUTLETS ON ANY ONE 1 EA WALL STOP 1 EA WALL STOP KEY OR SPECIAL KNOWLEDGE OR EFFORT. e- CIRCUIT. ALL WALL PLATES WILL BE WHITE UNLESS OTHERWISE NOTED. EXISTING DOORS, FRAMES, AND HARDWARE TO BE RELOCATED IF FEASIBLE. O W 6. ELECTRICAL OUTLETS TO BE PROVIDED BY SUBCONTRACTOR TO MEET ELECTRICAL SEE DEMO PLAN 1/T1,1. PROVIDE NEW DOOR PER SCHEDULE AS0) CODE. CONTRACTOR TO VERIFY WITH TENANT EXACT LOCATIONS AND NECESSARY. — REQUIREMENTS OF ELECTRICAL AND PHONE/DATA OUTLETS. TENANT RESPONSIBLE � N M FOR CONTRACT FOR LOW VOLTAGE DESIGN AND INSTALLATION. 0 N NORTH N5 FLOOR PLANz o � 0 W ELEVATION KEYNOTES a --,z o FINISH FLOOR PLAN LEGEND ROOM F 'I SCHEDULE 1 PAINTED GYP. BOARD PER SCHEDULE - N 0 -- - -- ROOM # ROOM NAME FLOOR BASE N WALL E WALL S WALL W WALL CEILING HEIGHT NOTES 2 4" RUBBER BASE PER SCHEDULE Z Z Z o:: W = � + CORRIDOR 101 RECEPTION CPT-1 B-1 W-1-A W-1-A W-1-A W-1-8 C-1 (E) 3 PL-1 CABINET WITH ADJUSTABLE SHELVING Z = 0 `; 101 ROOM NAME & NUMBER WHERE SHOWN W 102 OFFICE CPT-1 B-1 W-1-A W-1-A W-1-A W-1-8 C-1 (E) O PL-2 COUNTERTOP WITH BACK AND SIDE OF,IC .•, 103 OFFICE CPT-1 B-1 W-1-A W-t-B W-1-A W-1-A C-1 (E) SPLASH WHERE SHOWN >N 5 ADA ACCESSIBLE SINK NEW CPT-1 FEET I F) NEW VCT-1 104 OFFICE CPT-1 B-1 W-1-A W-1-B W-1-A W-1-A C-1 (E) `> 6 ADA HEIGHT DISHWASHER BY TENANT 0 _•: .� r•."••:: ; '':: 105 OFFICE CPT-1 B-1 W-1-B W-1-A W-1-A W-1-A C-1 (E) CD 106 BREAK ROOM VCT-1 B-1 W-1-A W-1-A W-1-A W-1-A C-1 (E) 7 REFRIGERATOR BY TENANT10 M W,m Ift=,>WF •.... •�� ��• , ..• . . 107 OFFICE CPT-1 B-1 W-1-A W-t-B W-1-A W-1-A C-1 (E) E 'o F �` R ' EPTION MIISH FLOOR PLAN GENERAL NOTES ROOM FNSI'ES INDEX'RE 4 5 �.• '101 T7.2 T7.2 Ti c . .. n 1. PATCH AND REPAIR (E) FINISHES TO MATCH WHERE DAMAGE HAS FLOOR FMIISl S WALL. R1�5 CASEWORK 3'-4" 2'=1 2'-10 1 OCCURRED DUE TO DEMOLITION. CPT-1 CARPET; BIGELOW: SKETCHPAD W-1 PAINTED GYPSUM BOARD; PL-1 VERTICAL SURFACES (BREAK BT296, WILDERNESS 7848 W-1-A BENJAMIN MOORE ROOM): NEVAMAR, MARRAKESH 3 2. PAINT ALL NEW WALLS U.N.O. FIELD COLOR W-1-A. KINGSPORT GREY HC-86 EXPRESS TEXTURED KH2O01T - \ 3. VERIFY All FINISH SELECTIONS WITH TENANT AND OWNER. VCT-1 VCT; MANNINGTON: ESSENTIALS FIELD U.N.O. PL-2 COUNTERTOPS (BREAK ROOM): - ;:•., •. ..` .1 FLAX 143 W-1-B BENJAMIN MOORE WILSONART, ANTIQUE BRUSH SMOKE GREY 2120-40 4823-60 5 FF E'`:,: ' .'. , , `..1 ,..': '•GfFI F :. :OFFICE'. :'.; 1 4: fos : 1az. BASE CEMM FNS" PL-3 VERTICAL SURFACES 1 •. M1: :; : .; .: , ;-',� : • ; ?:.; B-1 FLEXCO 4" RUBBER BASE, C-1 (E) 2x2 ACOUSTICAL LAY-IN (RECEPTION): PIONITE, CEILING CORIANDER FIBER AT981 / \ i BARK 02 REPLACE DAMAGED TILES (RECEPTION): 3 COUNTERTOPS as WILSONART, MORRO ZEPHYR EC6)] 7O � : ;..: ••.; „ .... . .. ... ... ... .,:• ... .• .. � .;. � .�. .;. . . MATCH EXISTING 2 \ / FLOOR OOR PLANS & DETAILS E CLEAR NOT11 I3,H s FINISH FLOOR PLAN 12 CASEWORK: BREAK ROOM 106 Tld 1/4" = 1'-0" JOB N0. 150197.01 9 o - ©2016 COk P.C./0DA ALL RKIM R6DtJFD 0 w I' Ln DEMO RCP GENERAL NOTES PLASTIC LAMINATE AT ALL EXPOSED PLASTIC LAMINATE AT ALL EXPOSED 1. SEE SHEETS T1.1 FOR ADDITIONAL DEMOLITION WORK. EXTERIOR SURFACES TYP. EXTERIOR SURFACES TYP_ 2. SALVAGE AND REUSE EXISTING CEILING TILES/LIGHTING FIXTURES c SHELF PIN HOLES ® 1" O.C. TYP. W/ ADJ. ® SHELF PIN HOLES ® 1" O.C. TYP. W/ ADJ. WHERE POSSIBLE. czmmm== PLASTIC LAMINATE (TYPE TBD) SHELVES cmmmm== PLASTIC LAMINATE (TYPE TBD) SHELVES 0 0 N " WIRE PULLS - LOCATE 1-1/2" FROM N C WIRE PULLS - LOCATE 1-1/2' FROM VERTICAL EDGE (TYP.) ° VERTICAL EDGE (TYP.) DEMO RCP LEGEND� ., � MELAMINE ALL INTERIOR SURFACES TYP. MELAMINE ALL INTERIOR SURFACES TYP. (E) 2X2 LAY IN ACOUSTICAL CEILING GRID 1'-1" 1'-1" I i PLASTIC LAMINATE COUNTER TOP W/ 4" PLASTIC LAMINATE COUNTER TOP W/ 4" SIDE AND BACKSPLASH, FLAT EDGE, TYP. SIDE AND BACKSPLASH, FLAT EDGE, TYP. 1 m (E) 2X4 LAYIN FLUORESCENT LIGHT FIXTURE o 0 cli t2'-1° PROVIDE FIRE TREATED BLOCKING AT V 2 -1 PROVIDE FIRE TREATED BLOCKING AT ---_'1 (E) 2X4 LAYIN FLUORESCENT LIGHT FIXTURE TO BE Z'�: LOCATIONS SHOWN LOCATIONS SHOWN RELOCATED WIRE PULLS — LOCATE 1-1/2" FROM TOP CABINET BEYOND LLiE — __ _ EDGE (TYP.) MELAMINE AT ALL CABINET INTERIORS TYP. — — — — DISHWASHER -- TENANT PROVIDED, En CONTRACTOR INSTALLED PLASTIC LAMINATE AT ALL VERT. EXTERIOR I i o —_ _ _ — SURFACES TYP. o z cn II II ca — 1 T S 4" RUBBER BASE PER SCHEDULE N 4" RUBBER BASE w� w (L a CABINET NOTES w `a `O 1. VERIFY DIMENSION IN FIELD PRIOR TO a N N FABRICATION a to N `r 2. FILLER PANELS TO MATCH CABINET FACE 'IF w o .- MATERIAL o 0 N NORTH U) N /yi1 DEMO RCP WALL AND BASE DRAWER SECTION r4'), WALL AND BASE SECTION @ D/W T12 1/8" = 1'-0" T12 3/4" = 1'-0" 064023-07 T1, 3/4" = 1'-0" 064023-07 1 RCP GENERAL NOTES 1. THIS DRAWING IS DIAGRAMMATIC AND FOR DESIGN PURPOSES ONLY. , ALL CONDITIONS TO BE FIELD VERIFIED. NOTIFY A/E OF ANY PLASTIC LAMINATE AT ALL EXPOSED DISCREPANCIES. EXTERIOR SURFACES TYP. 2. ELECTRICAL CONTRACTOR TO VERIFY MINIMUM EMERGENCY EXIT WIRE PULLS - LOCATE 1-1/2" FROM ILLUMINATION WITH BATTERY BACKUP AT EGRESS PATH OF TRAVEL - CLCL VERTICAL EDGE (TYP.) PROVIDE 1 F.C. MIN. EMERGENCY LIGHTING AT PATH OF TRAVEL. THIS LEVEL MAY DIMINISH TO NOT LESS THAN 06 F.C. OVER 1.5 HOURS OF ' MELAMINE ALL INTERIOR SURFACES OPERATION. � 3 3. CEILING HEIGHT TO MATCH EXISTING — 8'-6"f U.N.O. (VERIFY) 15895 SW 72ND AVE SUITE 200 PORTLAND, OREGON 97224 BR AK 4. CONTRACTOR TO PATCH CEILING ABOVE DEMO WALLS AND AT 1 -1 T E L : 5 0 3 . 2 2 6 . 1 2 8 5 1 s 1 7 RELOCATED LIGHTS AS NECESSARY. REPLACE DISCOLORED TILES. F A X : 5 0 3 . 2 2 6 . 1 6 7 0 PLASTIC LAMINATE COUNTER TOP W 4' w W W . C I D A I N C . C 0 M 5. WHEN POSSIBLE, USE SALVAGED LIGHTING FIXTURES. LOCATE ACCORDING TO 5/T1.2. SIDE AND BACKSPLASH, FLAT EDGE/TYP. 6. CONTRACTOR TO COORDINATE LIGHTING WITH EXISTING HVAC. LOW PROFILE SINK - PROVIDE DRAIN PIPE 105 7. RELOCATE (E) HVAC CONTROLS AS NECESSARY AND PROVIDE (N) HVAC INSULATION COVER. CONTROLS AS REQUIRED. 2'-1" RCP LEGEND PROVIDE FIRE TREATED BLOCKING AS O �- RCETI N REQUIRED. INSULATED EXPOSED DRAIN & HOT WATER CORRIDOR SUPPLY PIPINGS 101 ROOM NAME & NUMBER PLASTIC LAMINATE AT ALL EXPOSED (E) 2X2 LAY IN ACOUSTICAL CEILING GRID EXTERIOR SURFACES TYP. OF ICE OF--ICK OF--ICOF IC - VERIFY SUPPORTS. SEE DETAIL 9/T1.2. o MELAMINE AT ALL INTERIOR SURFACES TYP. 1 z N N HATCHED AREA INDICATES ADA CLEARANCES O (E) 2X4 LAYIN FLUORESCENT LIGHT FIXTURE O 2X4 LAYIN FLUORESCENT LIGHT FIXTURE 4" RUBBER BASE x _ W NOTE: PROVIDE A MINIMUM 30" 0) '-- 2X4 2X4 LAYIN FLUORESCENT LIGHT FIXTURE WITH 3" 6' 6 CLEAR WIDTH UNDER SINK WHEN NORTH BATTERY BACKUP 1'-5" DOORS ARE OPEN O N th 5 REFLECTED CEILING PLAN o E (NEW) ILLUMINATED EXIT SIGN s CABINET SECTION AT ADA SINK N �` N T12T12 3/4" = 1'-0" 064023-04 11.— 3 0 P--W m Lai INT. OR EXT. WALL ROOF OR FLOOR DECK — 12 GA. HANGER WIRES ® 4'-0" W 0 O.C. (TYP.) d Q SCHEDUS ION BRACE, SEE N 0 OTE 5 i 12 GA. SPLAYED BRACE WIRES z Q Q 00 (TYP.) MAXIMUM ANGLE FROM Z HORIZONTAL IS 45 DEGREES W NOTE 2 NOTE 6 I F" H CROSS TEE DUCT I 1 MAIN TEE NOTE 1 NOTE 4 NOTE 8 NOTE 7 I I N NOTE 3 FASTENER SCHEDULE m CONSTRUCTION TYPE FASTENER REQUIREMENTS 8 MAX WOOD 1/4" X 3" SCREW EYES 6'-0" MAX. 4'-0" O.C. MAX. (#12 WIRE) STEEL DECK PRE DROP WIRES, CMI OC1 OR DC, 2-1/4" MLTFAL DECK NOTES: SCREW LYES 1. LATERAL BRACING: 12 GA WIRE ® 12'-0" O.C. EACH WAY, MAIN RUNNER TO STRUCTURE. POST TENSIONED CONCRETE PRE DROP WIRES EMBEDS 1/4" X 3/4" METAL HIT ANCHORS BEGIN BRACING WITHIN 4'-0" OF PERIMETER AND 2" FROM CROSS MEMBERS. CAST IN PLACE CONCRETE PRE DROP WIRES, EMBEDS, 1/4- X 3/4- METAL HIT ANCHORS 2. ADDITIONAL 12 GA. HANGING WIRE WITHIN 8" OF PERIMETER. 3. STABILIZER BAR BETWEEN ALL MEMBERS ® PERIMETER. COMPRESSION STRUT SCHEDULE 4. TRAPEZE DUCTWORK AND OTHER LARGE OBSTRUCTIONS, COUNTER SLOPE. HANGER WIRES AND MAX. LENGTH OF STRUT STRUT REQUIREMENTS BRACING CANNOT TOUCH DUCTWORK OR PIPES. 5. CONNECTION DEVICE TO HAVE 200# CAPACITY. OR 3 TIMES CEILING DESIGN LOAD PER 5'-10" 1/2' DIA. CONDUIT EMT MANUFACTURER. SEE SCHEDULE. 7'-8" 3/4" DIA. CONDUIT EMT g REFLECTED CEILING g 6. VERTICAL STRUTS AT 12'-0" O.C. E.W. 9'-9" 1" DIA. CONDUIT EMT PLANS & DETAILS 7. 2" WALL ANGLE WITH #6 SCREW AT 2'-0" OC MIN. 12'-0" SINGLE 1-5/8" X 20 GA METAL STUD 8. ATTACH END OF GRID FRAMING TO WALL ANGLE ON TWO SIDES OF ROOM. PROVIDE 3/4" 15'-0" BACK TO BACK 1-5/8" X 20 GA METAL STUDS CLEARANCE AT FREE ENDS OF GRID FRAMING. 13'-6" SINGLE 2-1/2" X 20 GA METAL STUD T1,2 SUSPENDED CEILING SUPPORT AND 15'-0•' BACK TO BACK 2-1/2" X 20 GA METAL STUDS 8 LATERAL BRACING PROVIDE HEAVY DUTY CEILING SUSPENSION SYSTEM CONFORMING TO THE REQUIREMENTS OPF ASTM C-635-00. JOB N0. 150197.01 'g REFER TO STANDARD FOR ADDITIONAL INFORMATION. COPIES ARE AVAILABLE AT ARCHITECT'S OFFICE ©2D16 ODI, P.C./Mk ALL RIMM RLSD✓B B T1. 3/4" = l'—O" mommmmm 095123-016 w