Plans (2) BUP2015 - 00232 RECEIVEP 2ss AUG 4 2015 ARTEMU 'L !ROSIA y TENANT IMPROVEMENT FOR CODE SUMMARY CITY OF CIGARD ORTLAND, OREGON BARNARD COMMERCIAL REAL ESTATE ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE BUILDINGDIVISION `� �) 6650 S.W. REDWOOD LANE, SUITE 330 WITH STATE AND LOCAL CODE REQUIREMENTS THAT APPLY, 6) PORTLAND OR 97224 INCLUDING BUT NOT LIMITED TO: OF 1 O •�9 2014 OREGON STRUCTURAL SPECIALTY CODE PROJ # 15590 THIS IS A TENANT IMPROVEMENT REMODEL TO ACCOMODATE A NEW TENANT. PROJECT TI • 2014 OREGON MECHANICAL SPECIALTY CODE(GMSC) � M �� • 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) 9 • 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT • 2014 OREGON FIRE CODE (OFC) ( 1-5 TO PORTLAND AREA OF WORK FIRE PROTECTION SPRINKLERING • ASCE-7-10 U I-5 TO SALEM HEATING, VENTILATION &AIR CONDITIONING WORK • ICC/ANSI Al 17.1-2009 (236) 237) 239) EXIT #291 --) ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE Q 4 -- u�l—iso 1. rJ s 72 ,;13 C 0 1 (240} nnD Q Q cc '. ;, � - z —N� ��++ o � A3 BUILDING INFORMATION 0 N O it) m �—uu 1 1 17i . ' �I�rr 18 (LL24� 9� BUILDING OWNER: PACIFIC REALTY ASSOCIATES, L.P. � a- � (Or1 r, (235) ' (241) nRm1V � OO 15350 SW SEQUOIA PKWY #300 Q Q O r PORTLAND, ORE 97224 0 NN 0/1, a o o�9 J 0C - w (503) 624-6300 (PHONE) U) w (j K (503) 624-7755 (FAX) c L O Q (232) (231); (22$ (226) lA z V1 (0211 i," BLDG. #: POC BLDG. 16(PTR #240) UjO W O (227) (226 L 0 PGP A CONST. TYPE : TYPE II-B O r' a 0- STORIES: 3 (229 "B<'': 72 D AVENUE AREA: 18,848 sf FIRST FLOOR 22,879 sf SECOND FLOOR 22,977 sf THIRD FLOOR W 64,704 sf TOTAL rc 1 VICINITY MAP z Q � W A2 SCALE 1 " = 300' N a TENANT INFORMATION W a TENANT: BERNARD COMMERCIAL REAL ESTATE O L OCCUPANCY: B W 0 OFFICE AREA: 1,498 sf Q LU LL m Q DRAWING INDEX Q �. Al VICINITY MAP, OVERALL BUILDING PLAN, PROJECT INFORMATION A2 PLANS AND DETAILS // AREA OF WORK A3 SPECIFICATIONS 0 M 1 15_0" -0" - - W - - - - - e o a LL a ° I U w U) wz r I z - - - - - - - Lo - - - - - d" E r U J N F O _ _ _ CE Q 0 Qcc0 0 ICE z m LL 0 ¢ 0 U (A H b CITY OF TIGARD 0- Q too O a LEM REVIEWED FOR CODE COMPLIANCE (A a- (° a Approved: [ I� ' OTC: REVISIONS O Pettttlt#: �U��n tS—oOa2��1 1 b Address: (orb �ZwR� )pp1 Suite #: 7 ,-30 2. Qo By: `.�..:.L . I< Date: � 3. 4. OFFICE COPY 5. 6. 2 )i BUILDING PLAN 7. Al SCALE 1 " = 20' 8. DRAWN BY: A.L.D. DATE: 7-22-2015 PERMIT/BID SET ��`S A14 CEILING PLAN LEGEND tAMIRTEML DEROSIAEXISTING LIGHT FIXTURE TO REMAIN OREGON GENERAL NOTES �p \" (E) LIGHT FIXTURE TO BE RELOCATED FILEOF CLEAN CARPETS 307 111- REMOVE ® RELOCATED LIGHT FIXTURE I OFFICE OFFICE OFFICE EXISTING PAINT ALL WALLS MILLER 8711 W SALIN p—) F3075 -4 303 DOOR LATEX PROJ # 15590 (N) RUBBER BASE TO MATCH EXISTING EXISTING SUPPLY AIR DIFFUSER 6-0- NEW DOOR SEE "A" ADD AN AI ® EXISTING RETURN AIR GRILL '2-2' (N) U) RETURN N 46" HIGH WALL ALIGN (N) COUNTER PROVIDE NEW +48 U DOOR TO MATCH _ EXISTING FIRE SPRINKLER HEAD ggqi BREAK +04P8E 302 FICE q' _p� EXISTING +�- (E) CABINETS ? ® ® LITHONIA LDN6 35/10 LW6 AR LD 277 TRW TO REMAIN +48' N OPEN OFFICE +48. +48' QCo +,�. (N) WALL FLOOR PLAN LEGEND L ' -- -J 4+48"$'_p• 48' ® (N) WALL OrY N O 48• L.L N O LLo - FTUI db, ® (N) DEMISING WALL SEE A2 0 Q O (O r IGH FI < RE 7 W o- I,- CO r 5 44 Oli! , RECEPTION b (E) DATA J fr R 300 ► (N) DATA (n W 0 ()Ch _ ) zQ (E) DUPLEX RECEPTACLE Cz -- PROVIDE (2) RECESSED CAN LIGHTS G 0 Q 111 r J (N) DUPLEX RECEPTACLE W O z LITHONIA LDN6 35/10 LW6 AR LD 277 TRW ~ M 0 x REMOVE DESK (N) DBL DUPLEX RECEPTACLE W t 0 = Q NEW DOOR SEE"B" Q r 0- 0- � i Lu 1 REFLECTED CEILING PLAN z 2 FLOOR PLAN z A2 SCALE 1/8" = 1' - 0" A2 SCALE 1/8" = 1' - 0" Q 0 W 17\1 Q � O U) � a (DF Q z :j W o o r El m � a Q a U w O 8.. $„ 2 2 (y) O w A WOOD DOOR B STOREFRONT U W U) WITH LIGHT KIT (ALUM) DOOR Q W z g N 1EfQ O lw— < cc< 0 0 rr (L 0 Z Cc 3-1/2"24 GA METAL STUDS AT 10'-0'0.0. LL OLL Cc z TO BLDG. STRUCTURE ABOVE FOR w (� u) -I WALLS LONGER THAN 12'-0" WITHOUT STEEN EACH END W/(G WALLS < FA ) #8 SHEET METAL SCREW QMM 0 l� R-11 BATT INSULATION 4'CENTERED OVER WALL U W a- (D a BLOCKING TYP. @ FASTENING POINTS METAL EDGE BEAD REVISIONS EXISTING SUSPENDED CEILING MOVE PACO TRIM O _ 1 c 2. 2 x 6 SOLID BLOCKING 3 3-1/2"BATT INSUL 12 x 12 CARRERA TILE TOP AND EDGE 12 x 12 MARBLE TILE - 4. -- -35/8"MTL. STUDS @ 24"O.C. 5 �IM 2 0 5 (TIGHT JOINTS) - - 5 5/8"GYPSUM BOARD BOTH SIDES CENTER UNE OF STUD A2 9 5 11-821 A2 6. 7. 8. O E , -- O (2) LAYERS a'PLYWD ito 12'x12"ANGLE DRAWN BY: Igo N A.L.D. "' ") ILII it DATE: ?-22-2015 3-1/2"BATT INSUL IN SOUND ATTENUATION WALLS 7 - - PERMIT/BID SET 4"RUBBER BASE-TYP. ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN ANCHORS AT 12"O.C. 1 x 1 STEEL TUBE KNEE BRACE -SCREW INTO METAL FINISH FLOOR STUD WITH#8 SMS @ 6"O.C. - PROVIDE ENOUGH BRACES SO THAT THE DISTANCE BETWEEN THEM IS NEVER MORE THAN 36"-MIN OF(3)-PAINT TO MATCH WALLA2 7 RACO WALL SECTION W/ SOUND INSUL. 8 ELEVATIONS — COUNTER 9 SECTION/ELEVATION COUNTER 10 END SUPPORT A2 SCALE 1" = V-0" A2 SCALE 1/2" = V — 0" A2 SCALE 1/2" = 11 - 01, — 0" AZ SCALE 3" = 1' — 0" A14 225 ARTEMU DEROSIA f�'2 P TLA D, OREGON OF 00 PROJ # 15590 SPECIFICATIONS C6 0100 00 GENERAL DATA GENERAL REQUIREMENTS 14.DISTRIBUTION DUCTWORK b 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OFTHE OREGON 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND a. SPIRAL ONLY IF EXPOSED. STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY, 8, DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR RAGS AT THE END OF EACH DAY. b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. Q 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING c. WRAP CONCEALED SUPPLY DUCTWORK IN NON�ONDRIONED AND SEMI-CONDITIONED SPACE WITH - NOTIFY ARCHITECT OFANY DISCREPANCIES PRIOR TOSTARTING THE WORK APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. MINIMUM R4.2 SU PONWITHFSKBARRIER. SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS Q O 3. CONTRACTOR PRIORAND SUBCONTRACTORSSHALLL.SUB PERFORM DUE DILIGENCEINSPECTIONSHALL C NSIDE STING e. PROTECT WORK OF OTHER TRADES. PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD CONDITIONS PRIOR TO SUBMITTAL IOA PROPOSAL. DE, N D N OFA PROPOSAL SHALL BE CONSIDERED SAMPLE. I. PROVIDE"WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. HANGERS AND FULL DIAMETER STRAP UP TO 18"D. LARGER THAN 10'MUST HAVE SADDLE TYPE � CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE CLAMP. Q (h THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 10 4416 FIRE EXTINGUISHERS 4k 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH ASCHLAGE MORTISE DOUBLE 1. EXISTING FIRE EXTINGUISHER TO REMAIN e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 - EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH 12 00 00 FURNISHINGS DEGREES. co N O DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMBED TO WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. O��y1�-- ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 11,TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. LL- Y N0 � LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. W Q r, co n SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEANUP. 09 00 00 FINISHES 15.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING GENERAL 12 2316 CABINET SPECIFICATIONS 16.DIFFUSERS: � 1 STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS It 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. (T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN O WORK COUNTER TOPS-CARRERA TILE OVER PLYWOOD. PROVIDE FABRICATED STEEL KNEE BRACES AS a. SUSPENDED CEILING SYSTEM N (r N INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. INDICATED. TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. (D (D 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 0 0 2100 00 FIRE SUPPRESSION : DESIGN I BUILD b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN W Cl) (() T COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING a. PAINT 1. ADJUST SPRINKLER HEADS AS REQUIRED TO ACCOMODATE NEW CONFIGURATION.PROVIDE SPRINKLERS TITUS 350;EXHAUST-METAL OR ALUMINUM-12"x 12"EGG CRATE DESIGN TITUS 50F. vJ W 00 CARPETS. b. TILE,MARBLE,GRANITE,STONE,AND GROUT BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2X2 CEILING TILE. c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED INDUCT AT/OR NEAR CLOSEST > Z Lo LO 8. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 09 2100 GYPSUM BOARD LAYOUT OF SPRINKLERS BY CONTRACTOR. WYE BRANCH. AREAS AND COMMON AREA. FLOORS TO BE SWEPTOR VACUUMED DAILY. GENERAL 23 00 00 HVAC : DESIGN/BUILD d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT W 0 W O COMPLETION. Z 9. PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT CONTRACTOR 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 518"THICK VERTICALLY ATTACHED TO METAL STUDS 24'O.C.WITH GAS METER L COMMON CORRIDORS AND STAIRS, OFA ANY DAMAGES TO SUITEENTRANCES,ETC. THECONTRACTOR WILL 17.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE r (h 0 BE RESPONSIBLE FOR THE REPAIR OFANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 1"TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL T19822O/100 WHERE POSSIBLE. Lo 0 = ACTIVITIES. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTATMODELNO.P374-28W -7 DAY Q r m D- LL 10.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING FINISHCOATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. TO TENANTS MOVE-IN. PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY RESTROOM FACILITIES. 3. ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHTANGLES OR PARALLELTO FRAMINGON EACH HVAC-BID PROCEDURE REQUIRE CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM 11.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH l"TYPE S DRYWALL SCREWS B"O.C.TO VERTICAL 1. FORBIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN THERMOSTATS AND BALANCE SYSTEM. PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL PROPER WORKING ORDER. 18.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. COMMON BUILDING AREA BE USED FOR STORAGE. AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING),EACH SIDE ANDOPPOSrrE SIDES. ` 4ATALL EXISTING WALLSREMOVE ALL NAILSSCREWSFASTENERSETCLEFT BY PREVIOUS TENANT AND 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH 19.HVAC TESTING. } 12.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. . , , , , . UNIT PATCH HOLES READY FOR PAINT. a. CONTROLSYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, `r 13.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 3. LIST TONNAGE OF EACH UNIT. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH WALL CONSTRUCTION MATERIALS APPROVED PLANS AND SPECIFICATIONS. 14. ELECTRICAL AN PLUMBINGFALL WORK PRIOR FOR MING OR CUTTING FOR INSTALLATION. HVAC-DESIGN PROCEDURE ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE b. SEQUENCES E WITH APPROVED SHALL N AND SPECIFICATIONS. TESTED TO ENSURE THEY OPERATE IN INSTALLATION. USE EXISTING AND/OR NEW TE THIS SPACE DESIGN MECHANICAL SAC SYSTEM PER DESIGN STANDARDS ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. It 15.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. LISTED BELOW.SEPARATE THIS SPACE FROM THE ADJACENT SPACES.MODIFY THE EXISTING SSTEM TO w 2. FRAMINGMEMBERSBE NOT INDICATED, HE THEY SHALL RAL BE AS NECERTIESSSARY INDICATED WHERE PHYSICAL STRUCTURAL ACCOMODATE THE NEW COFIGURATION.PROVIDE A RETURN AIR GRILL IN ROOM 307. c. ACOMPITH PACTRUST. COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND (\I LL 16.CLEAN THE RETURN AIR GRILLS AND THE SUPPLY AIR DIFFUSERS. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. FILED WITH PACTRUST. O 17.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TOARCHTTECT FOR � 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMINGTO ASTM A446/A 446MGRADEA 33000 REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 22.PROJECT CLOSE OUT DOCUMENTS REQUIRED: 18.FILL ALL PAPER AND SOAP DISPENSERS IN BREAK ROOM. ( NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. V 1 PSI)G60. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. J 19.PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' INCLUDE THE FOLLOWING: DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR a. DUCTING AND SIZES b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. a EL PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS AN APPROVED EQUAL. c. HARD COPY OF AutoCAD FILE ABOVE. SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/6'THICK WITH TAPERED EDGES CONFORMING TO ASTM b. SUPPLY AND RETURN LOCATIONS AND CFM d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS. CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 08 M MANUALS HAVE BEEN RECEIVED C-36. c. ROOF EQUIPMENT,SIZES AND LOCATIONS � r AND APPROVED. eCOLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATEDM 6. TRIM ACCESSORIES SHALL COMPLY WITH ASTM G . .1047, d. UNITS REQUIRING DUCTED SMOKE DETECTION � W 201T IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, e. THERMOSTAT LOCATIONS AND ZONENNIT ASSOCIATED THEREWITH 26 00 00 ELECTRICAL : DESIGN I BUILD FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED WALL CONSTRUCTION EXECUTION z TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING 1. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS GENERAL ` Z WHETHER OR NOT SHOWN ON THE DRAWINGS. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. g. ZONE DIAGRAM W 21.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. J MATERIALS LIGHTER THAN 18 GA. HVAC DESIGN STANDARDS 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOWSILLS TO BE ROUTED THROUGH BUILDING 2.AS USED IN THESE DOCUMENTS,MEANS TOALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 2 PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. m Y PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. 23.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. FASTENERS SHALL BE AT LEAST 3INCHES FROM THE EDGE OF CONCRETE SLABS. 1. 350 SQUARE FOOT PER TON. 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. 24.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSTNON 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY 3. PROVIDE TYPED UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. TENANT PRIOR TO CONSTRUCTION: 4. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO 1-FOOT TWO WEEKS OF PROJECT AWAR D.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE IAT O REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE a. EXTERIOR EXPOSURE AREAS CANDLE. REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS ASUBSTITUTION BY THE JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE b. INTERIOR AREAS,SIZE AND USE 5. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, Q CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS ATTOP WITH BATTERY BACKUP. DIRECTED AT CONTRACTOR'S COST. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. c. CONFERENCE/TRAINING ROOMS 25.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL AND ELECTRICAL 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION 6. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE. (INCLUDING FIRE PROTECTION SYSTEMS), SUBMIT A MINIMUM OF TWO COPIES OF ALL SHOP DRAWINGS FOR THE PROJECT. AND 24-HOUR USE. 208V/120V POWER FROM THE 48OV277V SYSTEM. SIZE TOBE BIDDER DESIGN. REVIEW AND APPROVALTOTHE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE COPY AND ONE COPY 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. a. TRANSFORMERS TO BE ENERGY STAR LABELED. WILL BE RETURNED TOTHE CONTRACTOR. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 6FINISH QUALITY: PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN STONS SHALL BE SPLIT INTO MULTIPLE ZONES. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR: rr . 26.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OFTHE FIRE PROTECTION SYSTEMS VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3TONS SHALL BE SPLIT INTO MULTIPLE c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C W CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BYA PROFESSIONAL ENGINEER AREA PROCESS TRADE NOMENCLATURE ZONES. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENTLASS H INSULATION, AT FULL LOAD CONTINUOUS LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN CT. HISAL TYPE OF SYSTEM. COORDINATE OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. OPERATION. EQUIP WITH 2-12 PERCENT ANFC TAPS AND FOUR 2-12 PERCENT BNFCTAPS. MAXIMUM C INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE J CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE USG"FIRST COAT" 'SAND AFTER TAPE/FINISH COAT(S) 5. UNITS: LENNOX,TRANE,YORK OR CARRIER-712-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 71/2 SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL ASSEMBLY AND CASE. G APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. THE ARCHITECT PRIOR TO INSTALLATION. 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 6. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE 9. TELECOMMUNICATION SYSTEM BY FUTURE TENANT. SHOWN ON PLANS. (7 CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. 27.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE 10.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 09 30 33 C'ARRERA TILE � 7. ROOFTOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLEUNITS 11.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. 01 73 29 CUTTING AND PATCHING 1. PROVIDE: 12 x 12 CARERA TILE TOP AND EDGE AS INDICATED ON DRAWINGS. SHALL BE PLACED SYMMETRICALLY INA UNE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. 12.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT LU 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK 2. USE LATICRETE THIN SET MORTAR. 8. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND BEING UNDERTAKEN. 3. FOLLOW LATICRETE,FLORIDA TILE AND TCNA PRINTED INSTRUCTIONS FOR TCNA C512 COUNTERTOPS. ROOFING. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THAY OPERATE m USE MOST STRINGENTINSTALL TILES TIGHT WITH NOJOINTSIN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. , . . a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF (J,J 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. WHERE INSTRUCTIONS CONFLICTU (n 09 53 00 SUSPENDED ACOUSTICAL CEILING CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. 13.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. 3. PERFORM CUTTING USING METHODS LEAST LIKELYTO DAMAGE ELEMENTS LY BE RETAINED. b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. 14.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA Z 0 4. SURFACES ESI NG MATERIALS EXTENT POS EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT 1. EXISTING STACEILINEDOR DAMAGED BOXES UNDER WINDOWSILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. Q LU Z SURFACES TO THE FULLEST EXTENT POSSIBLE 2. REPLACE STAINED OR DAMAGED TILES. C. CONDENSATE MUST BE TRAPPED AT UNIT. () 7. SEISMICALLY ATTACH UNITTO CURB IN CODE-APPROVED METHOD. 15.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TOTH E (V 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. 3. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TOTHE SPACE ABOVE THE CEILING. A SECTION W 6. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO 4. BENT OR DAMAGED T-BARS TO BE REPLACED. 8. ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OFA PULL STRING If I- Q I'-N ADDITIONALCOST. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND OFFICE LIGHTING < 0 0) 09 9123 PAINTING CLAMPED(S.S.WORM GEAR). 08 10 00 DOORS AND WINDOWS 0 INTERIOR: S. ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUSTAND 1. GROUP RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUT U.N.O. O m 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE CORROSION WITH OIL BASED PAINT(COLOR GREY). 2. OFFICE LIGHT FIXTURES-RE-POSITION FIXTURES AS INDICATED J ( Q 0 1. WALLS: !/ 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 10.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND 3. RECESSED LED DOWN LIGHT: LITHONIA LDN635/10 LW6 AR LD 277TRW m a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. RADIUS MANUFACTURER'S GUIDELINE. 0 W a. BAXTER AND FLAMING. (503)225-0486 0 (] m b. D&D DOOR (503 205-5533 b. NEW AND EXISTING ROLLER LIP LE FINISHEDSH. RESTROOM FI UNIFORM COVERAGE WITH LATEXMILLER'S 6200 ENAMEL. R 11.ECONOMIZER TO MEET CODE AND AS FOLLOWS: U- cc > Z 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. c. BENSON INDUSTRIES (503)907-2200 a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. O 2. DOORS AND FRAMES: LLI m d. GRANTSUPPLY b. BAROMETRIC RELIEF ON 5-712 TON UNITS. (360)887-0647 a. NEW WOOD-MATCH EXISTING. 0 O � 3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS c. 8TONS AND ABOVE MUST HAVE POWER EXHAUST. Q Q LO 0 (FINIS CUSTOM COLOR. b. EXISTING WOOD-TOUCH UP STAIN,SEAL AS REQUIRED,ANDRE-VARNISH WITH SATIN VARNISH. d In REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. d. 1 12 THRU 4-TON OSA INTAKE WITH DAMPER. m 3. GENERAL NOTES: 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, a. KEEP ALL HARDWARE,HINGES,AND DOORKNOBS CLEAN OF ALL PAINTSPLATTERS,DRIPS,OR ROLLER 12.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. SPRAY. 13.DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WITH SUPPLY AIR. EDGES OFSUPPLY REVISIONS 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. AIR SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. REVISIOI 1�V S 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. 2. 3. 4. 5. 6. 7. 8. DRAWN BY: A.L.D. DATE: 7-22-2015 PERMIT/BID SET