Plans (7) BUP2015 - 00086
X25
ARTEMUS DEROSIA y
TENANT IMPROVEMENT
J � PORTLAND, OREGON
for
OF Og
QPROFESSIONAL EYE CARE PROS # 15290
AREA OF WORK ASSOCIATES OF AMERICA
B _ = _ = PROJECT NARRATIVE4-1
Q
�
— -- _ PROJECT CONSISTS OF A TENANT IMPROVEMENT TO 4,864 SF Q
A _
(82) _ uJ OF EXISTING OFFICE SPACE TO ACCOMODATE A NEW
j — - �80) = Q TENANT. WORK SHALL INCLUDE BUT NOT BE LIMITED TO Q
> DRYWALL/METAL STUDS, CABINETS, DOORS/FRAMES, CO o
t_ PAINTING, MECHANICAL AND ELECTRICAL. ALL WORK TO o
C. COMPLY WITH ALL CURRENT CODES AND MEET ADA r
- - — REQUIREMENTS. W
i
N
ql�l
� (A WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT Orn oLOUI� � I I a0mr I¢ Til+� PLUMBING WORK o co i.
FIRE PROTECTION SPRINKLERING (D0 N N
— ( HEATING, VENTILATION & AIR CONDITIONING WORK (0 0
ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE W w� �j-
IBJ I I 11 I I1 I IT1T _ LID Lc)m
! II IIII — Q Ln O Z X
! I I I II r a a LL
BUILDING INFORMATION
N OWNER: PACIFIC REALTY ASSOCIATES, L.P.
15350 SW SEQUOIA PKWY #300
1
VICINITY
MAP PORTLAND, ORE 97224 U a
Al _
C (503) 624-6300 (PHONE)
(503) 624-7755 (FAX) W
000 [E
BLDG. #: BLDG. B (ttC082) �E a 0.
--- -------- --- CONST. TYPE.: II-B Q m
ILL
---------- --------
THIS IS AN EXISTING FOUR STORY OFFICE BUILDING OF 87,890 SF. 0 (5 3
THE BUILDING HOUSES MULTIPLE TENANTS AND IS FULLY W z_ (t
SPRINKLERED. EACH FLOOR IS LESS THAN 23,000 SF m
Qm
v
AREA OF WORK TENANT INFORMATION — �-
I TENANT: PROESSIONAL EYE CARE O Q
ASSOCIATES OF AMERICA
OCCUPANCY = B
I I ,
AREA = 4,864 SF Q
OCCUPANT LOAD = 49 OCCUPANTS W
I I # OF EXITS REQ'D = 1 EXIT
I I Q
- - U o
W1 . '
I I r
- i W
cc N
Q h o rn
Z
Hai
- ---- z cc o
' O Qaw
U 0o
! w
LL
O LL acnQ
U
I
® w O
OO J
CITY OP TIGARD can a N Oa
REVIEWED FOR CODE COMPLUNCB
Approve* REVISIONS
I
I Perna#:
I 15
Addwsat 1 .
2.
1 I
I I
Suite#t 190 3.
- I - By: I Date: 1�� (15 4.
I I5.
YY
OFFICE COPY 6.
I I
I I
I I
I I
I I
I I
I I
DRAWN BY:
I I
A.L.D.
DATE: 3/19/2015
PERMIT/BID SET
I I SHEET NUMBER
I I
L _J
N A 1
2 BUILDING PLAN
Al SCALE 1 " = 20' OF 4
FINISH SCHEDULE �`� %
- - - - - - - - - - - WALLS CLG.
ARTEMUS DEROSIA�7
H GENERAL NOTES: RM# NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING HT REMARKS RM# y
1O ALIGN 101 WAITG CPT RB (N)GB/PT1 (N)GB/PT1 (E)GB/PTI (N)GB/PT1 (E)S.A.T. 9'-0" -- 101PORTUaN , OREGON
102 RECPT CPT RB (N)GB/PTI (E)GB/PTI (E)GB/PT1 (E)GB/PTi (E)S.A.T. 9'-0" -- 102
2 PROVIDE BACKING IN WALL TO SUPPORT LARGE FLAT SCREEN TV 103 WORK CPT RB (N)GB/PT1 (E)GB/PT1 (E)GB/PT1 (N)GB/PT1 (E)S.A.T. 9'-0" -- 103 A
1 104 CONF CPT RB -- , OF O�
� O PROVIDE CEILING MOUNT FOR TENANTS PROJECTOR (E)(N)GB/PTi (E)GB/PTi (E)(N)GB/PT1 (N)GB/PT1 (E)S.A.T. 9'-0" 104
OFFICE H H 105 I.T. VCT RS N)GB/PTi (N)GB/PTi N)GB/PTi (E)GB/PT1 (E)S.A.T. 9'-0" -- 105
O4 PROVIDE 45"X 80"RECESSED MOTORIZED SCREEN 106 HALL CPT RS OPEN (N)GB/PTi OPEN (N)GB/PT1 (E)S.A.T. 9'-0" -- 106 PROJ # 15290
120 i 107 OFFICE CPT RB (N)GB/PT1 (N)GB/PT1 (N)GB/PT1 (N)GB/PT1 (E)S.A.T. 9'-0" -- 107
O RELOCATE (E) ELECTRICAL PANEL 108 OFFICE CPT RS (N)GB/PT1 (N)GB/PT1 (E)(N)GB/PT1 (E)GB/PT1 (E)S.A.T. 9'-O" -- 108
OFFICE OFFICE I 109 OFFICE CPT RB (N)GB/PT1 (N)GB/PT1 (N)GB/PT1 (E)GS/PT1 (E)S.A.T. 9'-0" -- 109
I DEACTIVATE FLOOR RECEPTACLES - REMOVE TRIM, INSTALL COVER PLATE AND PATCH U)
119 118 I O CARPET. IDENTIFY SOURCE(PATH OF FEED ON AS BUILT DRAWING FOR FUTURE 110 OFFICE CPT RB (N)GB/PT1 (N)GB/PTi (N)GB/PT1 (E)GB/PT1 (E)S.A.T. 9'-0" -- 110 f ,
111 BREAK VCT RB (N)GB/PTi (N)GB/PT1 (N)GB/PT1 (E)GB/PT1 (E)S.A.T. 9'-0" -- 111 lJ
1 I O7 SAWCUT FLOOR AND PROVIDE FLOOR RECEPTACLES FOR POWER AND DATA 112 OFFICE CPT RB (N)GB/PTi (N)GB/PT1 (N)GB/PT1 (E)GB/PT1 (E)S.A.T. 9'-0" -- 112
120 I 114 OFFICE CPT RB (N)GB/PT1 (N)GB/PTi (N)GB/PTI (E)GB/PT1 (E)S.A.T. 9'-0" -- 114
VEST,
118 O PROVIDE POWER AND DATA RECEPTACLES FOR TENANTS PROJECTOR ABOVE CEILING (E)(N)GB/PT1 (N)GB/PT1 (N)GB/PT1 (E)GB/PTi (E)S.A.T. 9'-0" -- 115 Q
115 OFFICE CPT RB
116 10'-0' I 116 VEST CPT RB (N)GB/PT1 (N)GB/PTi (N)GB/PTI (E)GB/PT1 (E)S.A.T. 9'-0" _= 116
10'-6" I 1117 OPEN OFFICE CPT RB (N)GB/PT1 (E)GB/PT1 (N)GB/PT1 (N)GB/PT1 (E)S.A.T. 9'-0" 117 Q
118 OFFICE CPT RB (E)GB/PT1 (E)GB/PT1 (N)GB/PTI (N)GS/PT1 (E)S.A.T. 9'-0"
1 i 119 OFFICE CPT RB (E)GB/PT1 (N)GB/PT1 (N)GB/PT1 (N)GB/PT1 (E)S.A.T. 9'-0" -- 119 U) O
OFFICE I 120 OFFICE CPT IRS (E)GB/PT1 (E)(N)GB/PT1 (N)GB/PT1 (E)GB/PT1 (E)S.A.T. 9'-0" -- 120 0 M
Lo
115 I W
115
AqPLEGEND: DOOR SCHEDULE QN
{ � J I-
b H DOOR DATA FRAME DATA HARDWARE Remarks Mark O O O U)
N OFFICE (N) 3j "STUDS @ 24"O.C. TO CEILING Mark Door Size Thk Core Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function U) ()fr
I
114 CNO I 101 3'-0"x 9'-0" 1 3/4" SC SAPELE CHERRY Right TIMELY it 4 7/8" LEVER/LOCWCLOSER SCHLAGE 605 POLISHED BRASS ND92PD E.T.R. 101
O (E) DUPLEX RECEPTACLE 103 3'-0"x 9-0" 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S == 103 >z N(�t
114 104 3'-0"x 9'-0" 1 3/4 >" SC SAPELE CHERRY Right TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S 104 O O
(N) DUPLEX RECEPTACLE w (A J
105 3'-0"x 9'-0' 1 3/4' SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL80PD -- 105 L�
(N) DOUBLE DUPLEX RECEPTACLE 107 3'-0"x 9'-0' 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 107 err- �� �to
OFFICE 108 3'-0"x 9'-0" 1 3/4" SC SAPELE CHERRY Right TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 108 LL C)0 2 X
n (E) PHONE/DATA 109 3'-0"x 9-0" 1 3/4" SC SAPELE CHERRY Right TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 109 Q r 0 d LL
n 112 I 110 3'-0"x Y-0" 1 3/4" SC SAPELE CHERRY Right TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 110
112 OPEN OFFICE I Q (N) PHONE/DATA 111 3'-0"x 9-0" 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S 111
117 I i� POWER INPUT FOR FURNITURE 112 3'-0"x 9'-0" 1 3/4" SC SAPELE CHERRY Left TIMELY 11 4 7/8" LEVER LATCH SCHLAGE 505 POLISHED BRASS AL10S 112
rF
I 114 3'-0'x 9'-0' 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 114
I
(N) PHONE /DATA INPUT FOR FURNITURE 115 &-0'x 9-0' 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 115
_
116 3-0'x 9'-0" 1 3/4" SC SAPELE CHERRY Left TIMELY II 4 7/8" LEVER/LOCK/CLOSER SCHLAGE 605 POLISHED BRASS ND92PD E.T.R. 116
BREAKS 6w FLOOR RECEPTACLE TO BE REMOVED 118 3'-0"x 9-0' 1 3/4" SC SAPELE !CHERRY Left TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S -- 118 ! , W119 3-0"x 9'-0" 1 3/4" SC SAPELE ERRY Left TIMELY 11 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S 119f7(N) FLOOR RECEPTACLES (1) ELECT(1) DATA 120 3'-0'x 9-0" 1 3/4" SC SAPELE ERRY Right TIMELY II 4 7/8" LEVER LATCH SCHLAGE 605 POLISHED BRASS AL10S 120 m ^ LOi
O I ® LL 0
FIRE EXTINGUISHER W/CABINET
1 111 — E.T.R. = EXISTING TO REMAIN W O Q
U
H H Q Q
110 36" 36" F
OFFICE LL 4k (n
°) 11 O I RACO HEAD
0'76 Z
ILL
I FINISH MATERIALS- (TAN) W
ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION.
109 o
OCARPET LOOP PILE: w
OFFICE * I CPT PATCRAFT 10129 - NIGHT MOVES, 29703 LIONS TIGERS &BEARS, DIRECT GLUE Z-O" U PROVIDE HC SIGNAGE FOR
LL
109 Cf ALL NEW AND EXISTING H U
1 VINYL COMPOSITION TILE w RR'S KROY#2835207 O
VCT ARMSTRONG STANDARD EXCELON 51899 COOL WHITE, 12'k 12"x 1/8" BLACK(MEN) KROY
Z Z 2 #2835209 BLACK(VVOME ) U)
P 107 d H BASE o E //�
108 RB BURKE MERCER 4' RUBBER BASE, 597 MOCHA Q U)
HP LL' OFFICE CONF /;� I FLAT AT ALL CARPET AREAS, COVE AT ALL HARD SURFACES.
b OFFICE los 107 104 a,7 a TEMP O
T 108 2 ;% I GLASS O LL ADDITIONAL
rn n 5 `3� �7 u;'/ b � PAINT: (3 w O SWITCH GANG W
4'-0" v rt L ''S PT-1 MILLER 4480 PREMIUM SATIN 8721 W CLAY BEIGE, SATIN LATEX. Z_ J LOCATION Cc
1 � L PT-2 MILLER 4480 PREMIUM SATIN 8724M MEADOWLARK, SATIN LATEX (ACCENT COLOR) T U 5"
OR 0
_j ( l
I•T• 105 I
LAMINATE:WILSONART 1530-60 BEIGE,AT ALL FACES w F Q w `� O
105 104 0 - 1 PL-2 WILSONART 4669-60 NATURAL TIGRIS COUNTER, B.S. AND SELF-EDGE. w w O W 07
WAITG
O ELECTRICAL w C '-
H 1 101 103 CAB PULLS 65 POLISHED BRASS OR J-BOX p = ¢ Z
DOORS, HARDWARE AND FRAMES UNDERCUT DOOR (1)00 = O W N
WORK \ AS REQUIRED TO F o
RECPT DOORS RIBBON SAPELLE WITH CHERRY FINISH p ao -1
102 1 103 ♦ HARDWARE 605 POLISHED BRASS FINISH I— Q 0)
b CLEAR FLOOR r� v � m � W }�
FRAMES TIMELY II, PAC RED z
101 I z wZ
fivCONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. U Cc 0
II 2 ELEVATION - DOOR W/ SIDELIGHT 3 MOUNTING HEIGHTS Q = w
1 -1 " I NOTE: THE EXISTING CARPET IS TO REMAIN EXCEPT WHERE VCT IS SPECIFIED. A2 SCALE 1/2" = 1' - 0" A2 SCALE 1/2" = 1' - 0" /�
REMOVE CARPET WHERE NECESSARY AND PATCH BACK TO ACHIEVE SEAMLESS REPAIR. vJ0
I 00
W Q "D
I o LL o � Q
I w 0 [z 0)
I EXISTING WINDOW WALL MULLION C Qd @10
SAWCUT FOR UTILITY TRENCH ACTUAL SHAPE AND SIZE MAY VARY
N FILL OVER CUTS WITH EPDXY (MM80) FROM EXTRUSION SHOWN
EXISTING GLAZING REVISIONS
ALIGN TOP OF(N) SLAB WITH TOP OF(E)
1 FLOOR PLAN SLAB USE 3,000 PSI CONCRETE MIX AND
A2 SCALE 1/8" = 1' - 0" PROVIDE SMOOTH HARD TROWEL FINISH.
_? 32" ROCKWOOL SOUND CURTAIN FROM TOP 2.
OF WALL TO ROOF STRUCTURE ABOVE.
%j ATTACH ABOVE WITH STUD TRACK 3.
„ #4 REBAR, 12" LONG @ 24"O.C. WITH 6"
3/16"x 1/2" BLACK FOAM INSULATION TAPE
' EMBED EACH SIDE - LOCATE IN CENTER 20 GA 3 5/8" METAL STUD BRACING TO ROOF 4.
" —STRUCTURE AT 10'-0"OC WHERE REQUIRED
a OF SLAB 5.
SECURE EACH END W/(1) #8 SHEET METAL
SCREW
td� ���
PACO STYLE RECESSED REVEAL 6.
TRACK, CONCEPT WALLS EXISTING SUSPENDED ACOUSTICAL CEILING TILE
#1-487RDT CENTER ON WINDOW t`='
RESTORE VAPOR BARRIER IF PRESENT MULLION AND SECURED BY GYP `j' RACO STYLE RECESSED REVEAL HEADER.
BOARD. DO NOT SCREW INTO CONCEPT WALLS #1-487RDT
( WINDOW MULLION 1 =? 3-1/2" ROCK WOOL INSUL.
2" CONDUIT FOR DATA i'.
^` 3-5/8" MTL. STUDS @ 24"O.C.
DRAWN BY:
1" CONDUIT FOR POWER I 5B"GYP. BD. BOTH SIDES A.L.D.
i Z? CENTER LINE OF STUD
EXISTING WINDOWSILL
COMPACTED 3/4"MINUS CRUSHED ROCK 3-1/2" ROCKWOOL INSULATION DATE: 3/19/2015
;/ -
COMPACT TO 95%ASTM 1557 WALL STUD FLUSH WITH WINDOW SILL PERMIT/BID SET
GYPSUM BOARD 4" RUBBER BASE-TYP. SHEET NUMBER
UNDISTURBED SUB-GRADE _ ATTACH BOTTOM TRACK TO FLOOR WITH
POWDER DRIVEN ANCHORS AT 12"O.C.
FINISH FLOOR
A2
4 UTILITY TRENCH / CONCRETE SLAB REPAIR rFNWALL TO MULLION CONNECTION 6 WALL SECTION W/ SOUND INSUL.
A2 SCALE 1" = 1' - 0" A2 SCALE 3" = 1'-0" A2 SCALE 1 " = 1'-0"
OF 4
225
225
- - - �' 2L.
ARTEM L DERGSIA y
108^ T ND, OREGON �1
(3) EQUAL SECTIONS OF O�
I,' ': L�l ' - - - - - -
�R. PROJ # 15290
/A/DJ. HELP,, I ///DJ. HELF\ I �DJ. HELF�
� _ _ = = = = � L _ _ _ _ _ _ � � _ _ _ _ _ _ �
V /I V V /I io
fiH
I/ \I P -1 P -1 P -1
1 - - _ _ - - � � - - _ _ - - � Q
1 \ T II \ T II 1 1 Q
- - - ' - - -
I m Q
U) O
/\� /\I 1 a ® I ® ® O m
CcW
— o Go
AT PINK- 110 Q N
—cl) J. SHEL� DAN \ PL-1 ADJ. SH— O 0
0 Lo
AI L-1
PL/ U Q 0 p r
U)
— — — — — — — — In
OPEN BASE >Z
2
24l„ W
2 0 g (y)cr)
n / 4" 4 36" 24" I— p 00
cl
y jto to
1084" LL Lo0 2X
Q
r� a-LL
I
1 2 BREAK ROOM CABINET ELEVATION
A3 SCALE 1/2" = 1' - 0"
I� \I W
LEGEND: 0
(E) LIGHT FIXTURE TO REMAIN w N O
CW °0
/\ j �x�JI (E) LIGHT FXTURE TO BE REMOVED/RELOCATED Q a
PIC
�- m IA
j i RELOCATED LIGHT FIXTURE (18 CELL PARABOLIC) �O//�� Z
v!
LIGHT FIXTURE(WITH STEADY BURN BALLAST) C
;\ W
J
1 \ - 40. LED WALL WASHER (RECESSED CAN) Q
� I
(1) (E) EXIT LIGHT77
v
jkl \% \ /I \%I i\% f0fnn
O (E) SENSOR !v!nJ
e � vJ
\I I (E) SPRINKLER HEAD
/ r� W
Ir
/I I\ /I \\� \ i (E) SUPPLY AIR DIFFUSER
E
/ \I
/ \I L\1
T . �R (E) RETURN AIR GRILL O
°'
® (N) RETURN AIR GRILL > 111
H / _ W 5d
— I'�; N
�, I SHADED AREA INDICATES EXIT PATHWAY —I I N
2��/ \I / \I \ \ � REQUIRING EMERGENCY LIGHTING EQUAL Q FW— Q r-
� `1 TO l FOOT CANDLE z z Z
i0 cr Q a c°��
U) =
c/) 0
i < �
W
I O u- UIQ
O LL O J
U d 0 cc
r d
N REVISIONS
1 FLOOR PLAN 1 .
A3 SCALE 1/8" = 1' - 0" 12.
3.
4.
5.
6.
DRAWN BY:
A.L.D.
DATE: 3/19/2015
PERMIT/BID SET
SHEET NUMBER
A3
OF 4
�2 5 `�
• ARTEMU1 DEROSIA y
PORTLAND, OREGON,
9 OFS [mijECIFIk,%� AT11%,,� Nti
PROJ # 15290
FD
U
0100 00 GENERAL DATA Q
GENERAL REQUIREMENTS 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 2. DOORS AND FRAMES: HVAC-DESIGN PROCEDURE
1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. a. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS
STRUCTURAL SPECIALTY CODE AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX LISTED BELOW. _
2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. CAULK,AND FINISH WITH SATIN OIL ENAMEL. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR
NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. b. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SATIN OIL REVIEW AND APPROVAL FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH
ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,AND RE-VARNISH WITH SATIN NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE.
3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR VARNISH. INCLUDE THE FOLLOWING: U)!n
) O
CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OFA PROPOSAL SHALL BE CONSIDERED HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OFTHE FINISHED DOOR SKIN W/STAIN AND FINISH
CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 3. GENERAL NOTES: a. DUCTING AND SIZES O m
THE CONTRACTOR FOR CLAIMS ARISING ASA RESULT OF FAILURE TO PERFORM SUCH INSPECTION. SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IFTHIS a. KEEP ALL HARDWARE,HINGES,AND DOORKNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER b. SUPPLY AND RETURN LOCATIONS AND CFM ry'
4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL SPRAY. c. ROOF EQUIPMENT,SIZES AND LOCATIONS L.L
EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSALALL WORK NECESSARY TO COMPLETE THE WORK SAMPLE. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. W
DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO g, ALL INTERIOR GLAZING SHALL BE TEMPERED. d. UNITS REQUIRING DUCTED SMOKE DETECTION
ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OFALL PAINT MATERIALS,RUBBISH,CANS,AND e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH
LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OFSUBSTRATE 10.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK RAGS ATTHE END OF EACH DAY. a_It
SURFACES PRIOR TO INSTALLATION,AS WELL AS FINALCLEAN UP. 09 00 00 FINISHES d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS Q N
5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDINGAND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. g. ZONE DIAGRAM Tl-
STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OFA DISCREPANCY TOTHIS GENERAL e. PROTECT WORKOF OTHER TRADES. HVAC DESIGN STANDARDS 0 O O L
INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. fr CO r
f. PROVIDE"WET PAINT'SIGNS AS REQUIREDTO PROTECTNEWLY PAINTED FINISHES. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS:
6. FURNISH ALL NEW MATERIALS EXCEPTINHERE W HERE SPECIFICALLY NOTED OTHERWISE. 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 0 f�
EXTERIOR: 1. 350 SQUARE FOOT PER TON. d.
I
7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO PROTECT EXISTING a. FLOOR COVERINGS AND BASE
CARPETS. b. PLASTIC LAMINATES 1. WASHING: 2. ADDRESS LOADS 8Y SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY � �> O CV CU
a. ALL SURFACES TO BE PAINTED ARE TO BE PRESSURE WASHED USING A PRESSURE WASHER WITH A TENANT PRIOR TO CONSTRUCTION: >z (Do
8. MEMBRANEALL ROOF AS
NEEDED.
PENETRATIONS FROM ABANDONED EQUIPMENTTO BE REMOVED. PATCH AND REPAIR ROOF c. ALL NATURALWOOD(INCLUDING DOORS AND CASEWORK) MINIMUM PRESSURE OF2500PSI. a. EXTERIOR EXPOSURE AREAS W u)Q
MEMBRANE AS NEEDED. � L'7(�
9. ALL ROOF WORKTO BE PERFORMED BY PACTR UST APPROVED ROOFING COMPANIES. APPROVED d. PAINT b. AFTER WASHING: b. INTERIOR AREAS,SIZE AND USE L0 I-
00
COMPANIES INCLUDE: e. HARDWARE 2. DO NOT PAINT OVER DIRT,RUST,SCALE,GREASE,AND MOISTURE. SCRAPE ALLSURFACESTO REMOVEANY c. CONFERENCE/TRAINING ROOMS L,L, Cel Lo Lr)
a. ARROW ROOFING, ALFONSO PEREZ (503)460.2767 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK SCALE. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5TON UNITS BASEDON USE&EXPOSURE CRITERIA. to 0 =X
b. PACIFIC ROOFING, GUY BELT (503)640-3163 092100 GYPSUM BOARD 3. ALL IRREGULAR SURFACES TO BE FEATHERED OUTAT EDGES BYSANDING. PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5TONSSHALL BESPLITINTOMULTIPLEZONES. rd Ll IL
4. ALL METAL SURFACES WITH VISIBLE SOILING TO BE WIPED WITH APPROPRIATE THINNER TO CLEAN. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3TONS SHALL BE SPLIT INTO MULTIPLE
c. GRIFFITH ROOFING, GREG STONE (503)643-1596 GENERAL ZONES.
10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 1. ALL GYPSUM BOARD TO BEA MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 5. SPACKLE ANY IMPERFECTIONS IN SURFACE WITH EXTERIOR SPACKLE,SPOT PRIME PRIOR TO INSTALLATION 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES EXCEPT I.T.CLOSETTO
AREAS AND COMMON AREA. FLOORS TO BE SWEPTOR VACUUMED DAILY. V TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. OF FINISH COATS. HAVE DUCTED RETURN AIR ONLY(NO SUPPLY)TO MAINTAIN AMBIENT TEMPERATURE.
11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT UMITEDTO 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COATAND TWO FINISH COATS WITH SANDING BETWEEN S. CAULK SEAMS ATJUNCTION OF ADJOINING SURFACES WHERE OPENINGS ARE VISIBLE TO THE EYE. 5. DISTRIBUTION DUCTWORK: F
COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 7. CONCRETE WALLS: d. 26 GAUGE OR TO SMACNA STANDARDS II��
BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 3. ONE LAYER 518"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR PARALLELTO FRAMING ON EACH
ACTIVITIES. a. NEW-PRIME WITH KRILL PRIMER SEALER AND FINISH WITH HIGH SHEEN KRILL TO ACHIEVE UNIFORM e. WRAP CONCEALED SUPPLY DUCTWORKIN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH
SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES DRYWALL SCREWS 8"O.C.TO VERTICAL COVERAGE. MINIMUM R4.2 INSULATION WITH FSK BARRIER.
12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND INTERMEDIATE STUDS. STAGGER ALLVERTICAL b. EXISTING-SPOT PRIME WITH KRILL PRIMER SEALER AND FINISH TO HIGH SHEEN KRILLTO ACHIEVE U
RESTROOM FACILITIES. AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING),EACH SIDE AND OPPOSITE SIDES. UNIFORM COVERAGE L HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD n
�j
13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITEDTO AREAS AS DESIGNATED AT 4. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. HANGERS AND FULL DIAMETER STRAP UP TO18"0. LARGER THAN WMUST HAVE SADDLE TYPE
PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 10 00 00 SPECIALTIES CLAMP. O
COMMON BUILDING AREA BE USED FOR STORAGE. 5. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND
PATCH HOLES READY FOR PAINT. 10 1100 VISUAL DISPLAY SURFACES g. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NOOCTOPUS). TEES SHALL BE MAXIMUM OF 45 1 I I O
14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALLTIMES. WALL CONSTRUCTION MATERIALS 1. PROJECTOR SCREEN: USE DA-LITE BOARDROOM ELECTROL,GLASS BEADED. SEE PLAN FOR SIZE. DEGREES. LJJ
15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. O
EL
1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE 10 28 13 BREAK COUNIER h. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. O
i. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FII4ISH CEILING. Q
16.ECON LEC RICALIZES AND
ALL OPENINGS REQUIRED FOR TNG ORINSTALLATION CUTTING
STRUCTURAL,MECHANICAL, INSTALLATION. ` 0-
ELECTRICAL
ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 Ci .,,.
2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 2. CUP DISPENSER-BOBRICK B-235 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. \
17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARYTO WITHSTAND ALL IMPOSED LIVE LOADS. 19.DIFFUSERS: i I In
18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 10 4416 FIRE EXTINGUISHERS LL
3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A4461A 446 M GRADE A(33000 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED ORINSEMI RECESSED CABINET AS INDICATED ON PLAN a. TITUSPSUSPENDEDCEILYANDTITUING (f-BAR)-PERF ORATED FACE ADJUSTABLE CURVED BLADES-DESIGN
19.FILL ALL PAPER AND SOAP DISPENSERS IN BREAK AREAS. ) TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL
PSI)G60. 2. FIRE EXTINGUISHER CABINET: A INDUSTRIES ACADEMY SERIES MODEL#C1027V10. b. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCTAT/OR NEAR CLOSEST z a
20.DRAWIN S MAY
I DRAWINGS OF THE WORK AT THE CONCLUSION OFCONSTRUCTION.MON.ED-BUILT' 4, PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONALGYPSUM OR
DRAWINGS MAY BE IN THE FORM OFTWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 1100 OD EQUIPMENT WYE BRANCH.
PEN.DELIVER RECORD DRAWINGS TOTHE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS AN APPROVED EQUAL. c. CLEAN OR REPLACE ALL SUPPLY RETURN Al GRILLS AND THEIR HOUSINGS AT PROJECT III 6 rm
1. DISHWASHER: GE GLDA690FWW WHITE,OR EQUAL APPROVED BY PACTRUST. L11 r'
SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5/9'THICK WITH TAPERED EDGES CONFORMING TO ASTM COMPLETION. Y
CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 08 M MANUALS HAVE BEEN RECEIVED C36. 12 00 00 FURNISHINGS 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEWTHERMOSTATS TO BE ED
AND APPROVED. 6. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 1. CLEAN/REFURBISH ADJUST BUILDING STANDARD BLINDS TO ACCOMODATE NEW WALLS AT ALL EXTERIOR HONEYWELL COMMERCIAL GRADE VISIONPR08000 TOUCH SCREEN MODEL TS8220U1003 WHERE POSSIBLE.
21.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, GLASS. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY
WALL CONSTRUCTION EXECUTION
FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED PROGRAMMABLE WITH LOCKOUT FU NCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY a
2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL ENTRY DOORS.
TO FU LFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM
WHETHER OR NOT SHOWN ON THE DRAWINGS. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW 12 23 16 CABINET SPECIFICATIONS THERMOSTATS AND BALANCE SYSTEM. U
22.ITEMS OR WORK NOTTO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD O
MATERIALS LIGHTER THAN 18 GA. 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR ATALL RESILIENT FLOORING LOCATIONS. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. `n
23."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 2 PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTERTOPS U.N.O 24.HVAC TESTING. )
V
PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS.
24.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. FASTENERS SHALL BEAT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 3. .M(MATCHING
SURECAMINABLE),TE FIN LAM HPL)
DOALL RS,ANDLGHTRIOR ACES,INCLUDING4"TOE CABINICK ET
BOT BANDING a. EQUIPMENCONTROL T
SSEMSHALL AREBE CA TESTED TO ENSURUSTEDE THAT ANDCONOPERATEIROL DEVICES,COMPONENTS, U)
(MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH V�
25.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OFTOP AND BOTTOM TRACKS. POSITION OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD APPROVED PLANS AND SPECIFICATIONS.
TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT MELAMINE FINISH. b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN
REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 1
REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE - LJJ
CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE NON-CONFORMING STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16'PARTICLE BOARD WITH MATCHING P-LAM OR c. A COMPLETE COMMISSIONING REPORT OFTEST PROCEDURES AND RESULTS SHALL BE PREPARED AND
PRODUCTS AS DIRECTED AT CONTRACTOR'S COST. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TOTHE TRACKS. PVC EDGES. FILED WITH PACTRUST. Cc
26-SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED:
PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMITA MINIMUM OFTWO COPIES OFALL THE PROJECT.AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALLTHE GYPSUM BOARD(OR 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. <
SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE AUQATOUGH) WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR. v
COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. S. HINGES-BLUM#75M3580,110 DEG.SELF CLOSING CLIP ON(OR EQUAL). b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. O
0)
27.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILTTYOFTHE FIRE PROTECTION SYSTEMS 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. c. HARD COPY OF AutoCAD FILE ABOVE. L
CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 6. FINISH QUALITY: ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS. LLl w
LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OFTHISTYPE OFSYSTEM. COORDINATE AREA PROCESS TRADE NOMENCLATURE 10.PULLS-96 MM C-TOC WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. i-
INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE WAREHOUSE TAPEIFINISH COAT" TIGHT DOUBLE
CENTERED IN CEILING TILE. LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN 11.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. 26 00 00 ELECTRICAL : DESIGN/BUILD ui
WRITING BY THE ARCHITECT PRIOR TO INSTALLATION. OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACKSPLASH IS INSTALLED IN ALL u) CJ
CASES TOALLOWCUTOUTTO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUTOUT AND BACK SPLASH GENERAL
28.COOROINATE ALL CONSTRUCTION SEQUENCINGWITH PACTRUST AND SCHEDULE ALL SERVICE USG"FIRSTCOAT" 'SAND AFTER TAPE/FINISH COATS) TOBESEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CLIT OUT TO J � N
INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. W } 1�
7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. Q Q O
29.CLEAN ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT COMPLETION SHOWN ON PLANS. 12.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOWSILLS TO BE ROUTED THROUGH BUILDING z
GENERAL 09 53 00 SUSPENDED ACOUSTICAL CEILING SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12"DX36'H-ATTACH TO WALL SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. W Z
WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 26"D. P-LAM AT TOEBASE. ALL SHELVES ADJ.HOLES
1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 1. THE SUSPENDED CEILING IS EXISTING.REPAIR ANY DEFECTS. AND POSTS(1 AT BASE,2AT UPPERS). 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. O 0 Q 0
TO INSTALLATION OF NEW FLOORING. 2. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES,INC.
01 73 29 CUTTING AND PATCHING 2100 DO FIRE SUPPRESSION :DESIGN/BUILD 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. Q = W
3. CO-ORDINATE CEILING WORKWITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO 1. PROVIDE SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2 4. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO I-FOOT
1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK INSULATION,GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. CANDLE. W S2 � 0
BEING UNDERTAKEN. SPRINKLERS �1 J
22 00 00 PLUMBING 5. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, CE
2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. 4. PRODUCTS: GENERAL REQUIREMENTS WITH BATTERY BACKUP. CC W Q O Q
3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. a. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) 6. FOR FLOOR POWER AND DATA ACCESS USE RACO#5511,2AT EACH LOCATION TO SEPARATE POWER AND 0 W D- > Z
4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT b. TILES-ARMSTRONG FISSURED ITEM#705,24 x 24x 518"W/ANGLEOTEGULAR EDGE 1. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE LL
INSULATED. DATA WITH 1"CONDUIT FOR POWER AND FOR DATA. (� (n Q
SURFACES TOTHE FULLEST EXTENT POSSIBLE 7. TELECOMMUNICATION SYSTEM BY TENANT. W O ~
c. ACCESSORIES-MANUFACTURERS'STANDARD 2. POINT OF DE MAN D WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER 0 �r�' I'L- O J
5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUTITRIM TILE EDGE TO CREATE TEGULAR EDGE FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR 8. LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. Q I.c U 0 cl
6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3x12"LONG REBAR DOWELS AT 24"O.C. MIN.WITH CONDITION SO THAT CEILING TILES LAY FLAT. AVAILABILITY,(503)236-4148. 9. OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WAIT STOP. D- Q N 0
MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN.OF 6'EXPOSURE INTO POUR BACK CENTER 7. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. 3. PLUMBING-BREAK ROOM FIXTURES 10.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT W r d
DOWEL IN SLAB.
ANCE WITH APPROVED PLANS AND
7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO 8. TUNE UP GRID SYSTEM TO WITHIN PLUS ORMINUS 0.5INCHES OFLEVEL 1. BREAK ROOM SINK ELKAY GECR2521 AND SYSTEMS SPECIFICATIONS. SEQUENCES OFOPERATONS ALL BEOPERATE
UINCTIONALLYTES ET DTOENSURE T AY OPERATE REVISIONS
ADDITIONALCOST. 9. BENT OR DAMAGED T-BARS TO BE REPLACED. 2. KITCHEN FAUCET DELTA 100-DST IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS.
08 10 OD DOORS AND WINDOWS 09 65 19 RESILIENT FLOORING-VINYL COMPOSITION TILE 3. 1/4"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF II.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE.
REQUIRED.
1. EXTEND FINISH FLOORING UNDER CASEWORK.
1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 23 00 00 HVAC : DESIGN/BUILD 12.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA
2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 2. INSTALL TILES IN QUARTER TURN PATTERN. BOXES UNDER WINDOWSILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH.
a. BAXTER AND FLAMING. (503)225-0486 09 9123 PAINTING HVAC-BID PROCEDURE OFFICE LIGHTING 2.
b. D 8 D DOOR (503)205-5533 INTERIOR: 1 FORBIDDING PROPER
PUR OSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN 1' OFFICEBALLASLIGHT 3
FIXTURES- LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL(NO SYLVANIA
c. BENSON INDUSTRIES (503)907-2200 1. WALLS: 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECTA CONDITIONS REPORT OF EACH
d. GRANT SUPPLY (360)887.0647
a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. UNIT 2. RECESSED LED DOWN LIGHT: LITHONIA LDN635/15 LW6 AR LS 277 TRW 4
3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(NIIM),ALPHA ALUMINUM b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 62000R 3. LIST TONNAGE OF EACH UNIT. 5
PRODUCTS,INC.(AAP),TIMELY 11,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING MATERIAL.NEW 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL
FRAMES TO BE FACTORY FINISH CUSTOM COLOR.
6.
[SHEET
RAWN BY:
A.L.D.
ATE: 3/19/2015
ERMIT/BID SET
NUMBER
A4
OF 4