Plans (8) BUP2015 - 00011 COPYRIGHT NOTICE: These drawings and specifications am copyrighted and subject to copyright protection as an "architectural work' under sec. 102 of the copyright act, 17 u.S.C. As EGRESS PLAN amended december 1990. This protection Includes, without limitation, the ,mrall form, arrangement and composition of spaces. and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure. .nd/or monetary liabllity. RECEIVED icpenney as 210 SM SF JAN 2 6 2015 CrTY OF TIGARD BUILDING DIVISION 0 o -7-il IDICK'S 4 -.-= SPORTING IS I N C E GOODS go,000 w Cr EM CITY OF TIGARD FOR CODE COMPLLki REVIEWED I i It Appmved. 0 j. L-V OTC'. 14 CD LM Pcmdt yxIPzC(:;7 Addreer. C-11 7C A)COAi.- `;L� M L-15;? S" MACY'S suite #: 24Z605 SF J ' By. Date: IM NO STROM OFFICE COPY cc Fr is ; I #I- I I WASHINGTON SQUARE 0 LU LU 9585 S.W. WASHINGTON SQUARE SPACE F09 1w :09 0 Md .----_-_,- V111 w M PORTLAND, OREGON 97223 w1w Milt M coo V) KEYPLAN PROJECT LOCATION PROJECT DATA INDEX OF DRAWINGS REVISIONS 1. PROJECT NAME:...........................................KIEHL'S i 2. SCOPE OF WORIIQ.............................................................INTERIOR RENOVATION OF AN EXISTING,MALL RETAIL SPACE. THIS SCOPE INCLUDES INTERIOR WORK AND NEW STOREFRONT AT THE MAIN MALL CONCOURSE. 1 T TITLE SHEET ri��jw_i . BUILDING: NEW INTERIOR PARTMON WALLS, NEW FLOOR FIXTURES & FINISHES, NEW CEILING S I N C E 1 8 5 1 L.00A-10%4 AND STOREFRONT. PECIFICATIONS . ELECTRICAL: NEW ELECTRICAL PANEL, LIGHTING, POWER OUTLETS AND PERIMETER TRACK 2 SP1 S LIGHTING. . MECHANICAL: NEW HVAC SYSTEM. 3 SP2 SPECIFICATIONS PLUMBING: NEW RESTROOM. FIRE: RE-WORK AS NECESSARY TO MAINTAIN INTEGRITY OF EXISTING SYSTEMS. 4 SP3 RESPONSIBILITY SCHEDULE & GENERAL NOTES 3. PROJECT LOCATIOft...................................WASHIIINGTON SQUARE 9585 S V� I W. WASHING-ON SQUARE SPACE F09 5 SP4 GENERAL NOTES & FINISH SCHEDULE PORTLAND, OREGON 97223 4. TENANT:....................................................... .................KIE�LS - SIINCE 1851 6 D1 DEMOLITION PLAN CONTACT: ADAM PECK PHONE: 917-606-2796 7 Al DIMENSIONED AND FINISH PLAN z ...........WASHIINGT(M SQUARE z & LANDLORD....................———---------- 0 9585 S.W. WASHINGTON SQUARE 8 A2 FIXTURE PLAN & FIXTURE/MILLWORK SCHEDULES z SPACE F09 PORTLAND, OREGON 97223 CONTACT:ROGER OTT 9 A2.1 FINISH PLAN AND DETAILS PHONE:(503) 639-5612 CO E Q 0) N N 0 6. TENANTS ARCHITECT:.................................................AAD+TrCK M. 10 A3 REFLECTED CEILING PLAN L) ; L0 tN- 16435 NORTH SCOTTSDALE ROAD, SUITE #195 .9 `,0 0 a ca) SCOTTSDALE, ARIZONA 85254 U) C 0) PHONE: (480) 998-4200 0 FAX: (480) 998-7223 11 A4 STOREFRONT PLAN, ELEVATION & SECTION Sr, L) < CONTACTS: + BLAIR S. LEACH, AIA, NCARB M LL ARCHITECT OF RECORD: 12 A4.1 SECTIONS AND DETAILS CL blaideach0ritch.com PROJECT MANAGER: NICHOLAS RUSH (PRIMARY CONTACT) nick.rush0fitch.com 13 A5 INTERIOR ELEVATIONS 72 U) N TS 14 A5.1 ENLARGED TOILET RM PLAN, ELEVATIONS & DETAILS z 0) RK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, THE REQUIREMEN 7. GOVERNING CODES.......................................ALL WO O� --7 FOLLOWING: 00 15 A6 SECTIONS AND DETAILS Uj BUILIDINI(k 2014 OREGON STRUCTURAL SPECIALTY CODE I + 2014 OREGON MECHANICAL SPECIALTY CODE MECHANICAL: v ELECTRICAL: 2011 OREGON ELECTRICAL SPECIALTY CODE 16 M1 MECHANICAL PLAN Ilesse a PLUMBING: 2011 OREGON PLUMBING SPECIALTY CODE M IBILITY: OSSC CHAPTER 11 ACCESSABILITY 0 ACCESS L) ENERGY: 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE 17 M2 MECHANICAL NOTES AND SCHEDULES In FIRE: 2007 PORTLAND FIRE CODE ULI 0 Ile— �x Neese 18 El ELECTRICAL POWER PLAN 0 AND ANY OTHER STATE AND LOCAL CODES HAVING JURISDICTION. IGHTING PLAN - 8. CONSTRUCTION TYPE. ..................—"--'TYPE II—B, SPRINKLERED 19 E2 ELECTRICAL L L) > 3: 9. OCCUPANCY: ...........................................-'—.M (MERCANTILE) 20 E3 ELECTRICAL PANELS & RISER DIAGRAMS 0 z 10. GROSS LEASED PREMISES...................................1,032 SQ. FT. 41 2=1E 4� ELECTRICAL SPECIFICATIONS lt OCCUPANT LOAD,.........................................................TOTAL NUMBER OF OCCUPANTS 27 SALES AREA: 752 S,F. 30 = 26 I WO STORAGE / TOILET AREA: 280 S.F. 300 = I N110 A,#C* TIME TOTAL NUMBER OF EMPLOYEES AT ONE 22 P1 PLUMBING PLAN BLAIR S. 12. EXIT REQUIREMENTS:....................................................1 (1) EXIT DIRECTLY FROM SALES, (1) EXIT FROM NON-SALES — LEACH te, 13. EXIT ILLUMNATION................................................_EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON SHEET E2. 23 P2 PLUMBING SCHEDULE 14. PLUMBING FIXTURE REQUIREMENT&-_TOTAL NUMBER OF OCCUPANTS = 27 WATER CLOSETS REQUIRED: 1 PER 50 PROVIDED: 1 SC TTSDALE.AZ U LAVATORIES REQUIRED: 1 PER 50 PROVIDED: 1 60.34 15. MISCELLANEOUS NOTES:.......................................TENANT'S GENERAL CONTRACTOR SHALL MST THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCIFION AND SHALL REPORT ALL DISCREPANCIES TO OF TENANT'S ARCHITECT. TENANTS GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD. 16. FIRE SPRINKLER SYSTEM..................................A FIRE SUPPRESSION SYSTEM IS EXISTING WITHIN THE SPACE. MODIFY AS MAY BE REQUIRED DATE: 12/23/14 SHEET: FOR NEW ALTERATIONS. ALL WORK SHALL BE PERFORMED BY A QUALIFIED & LICENSED FIRE 7 kii�E SPRINKLER CONTRACTOR. SEPARATE APPLICATION & PERMITS SHALL BE SUBMIT-FED AS AS N01i REQUIRED BY GOVERNING AUTHORITY. TENANT SHALL TAP INTO LANDLORDS MAIN LINE. ALL DRAWN By". VICINITY MAP WORK IS NEW AND BY TENANT. N.R. 17. DEFERRED SUBM11ITTALS...............--.FIRE ALARM PROJECT No.: 5201054`15 (UNDER SEPARATE PERMIT) FIRE SPRINKLER SIGNAGE COPYRIGHT NOTICE: SPECIFICATIONS These drawings and specifications are copyrighted .and ander to copyright protection as an "architectural work" under see. 102 be the copyright act, on uinclu As amended december 1990. The pro#eciion includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. GENERAL REQUIREMENTS 7. Substitutions: DIVISION SIX - WOOD AND PLASTICS C. Flashing and Sheet Metal under such protection, unauthorized use of these drawings and specifications may result in cessation of I 7a. Unless otherwise noted in the Contract Documents, substitutions will be considered if submitted in 1. Scope of Work: Provide and install galvanized sheet metal or lead flashing at any roof penetrations, construction, building seizure, and/or monetary liability. I Includes all materials, labor, equipment, tools, and operations necessary for the furnishing and installation writing to the Architect for rovol. A. Rough Carpentry P Y 9 9 PP exterior door and window heads, and at any other locations where required to prevent water intrusion into I of all items shown on the drawings end specified items herein, except for materials noted to be provided 7b. Contractor shall investigate proposed product and determine if it is equivalent to that specified. 1. Scope of Work: Provide miscellaneous blocking at metal framed walls, and b the Owner and installed b the Contractor. Refer to the Responsibility Checklist on SP3 for details. 7c. Include cost and/or time benefits for substitutions. Failure to include cost or time benefit is P 9 plywood sleeperficati ns. building. Provide and install sealants used in conjunction with flashing s. Y Y P Y / systems as described in the Drawings, the flooring manufacturer, and Division 9 of the Specifications. justification for rejection. 2. Standards: All sheet metal and flashing work to comply with the recommendations of the following For the purpose of this contract, the term "Owner" shall refer to Kiehl's Since 1851 and the term 7d. Architect shall be the judge of acceptability and reserves right to reject proposed substitution 2. Installation: standard: "Architect" shall refer to FITCH unless otherwise identified in lease documents. based on insufficient information. 2a. Plywood sheathing nails shall be driven flush but shall not fracture the surface of the sheathing. a. Sheet Metal and Air Conditioning Contractors' National Association (SMACNA) 'Architectural Sheet COfIdtl0na 2b. All nailing not specifically called out on the plans shall be per the building code. Metal Manual', 3rd edition. I Germ" 8. Contractor to provide certificate of Underwriter's Laboratory flame spread finishes and materials as 2c. Provide 2x solid blocking and backing for millwork, casework, display fixtures, bathroom accessories and AIA Document A201, "General Conditions of the Contract for Construction" dated 1987, shall govern required by local agencies and applicable codes. similar items attached to walls and ceilings. b. National Roofing Contractors Association I 'Roofing and Waterproofing Manual', 3rd edition. Work. Copy available from Architect upon request. 2d. Frame all stud walls full height, continuous to the bottom of floor joists or rafters, unless otherwise D. Banda and insurance S. Additional LaborWe noted in the Drawings. 3. Products: 1. Tenant shall employ only contractors licensed and workable in Pleasanton, CA. and shall require its The General Contractor is to include cost of the following in bid: 2e. Do not notch beams, joists, or studs unless otherwise noted or approved b Architect. 3a. Minimum gauge at all sheet metal flashing re be 24 gauge, unless otherwise noted in the Drawings, or Go p y y q g y where a heavier gauge is recommended by the referenced standards. contractor to provide labor and material payment, end performance bonds. Submit roof of bondabilit 2f. Provide double joists under all new parallel partitions. P P Ym P p Y 3b. Lead flashing to be four pound (1/16") lead with 6% to 7% antimony content. to owner upon request. 1. (4) Day Laborers for a total of (2) days to assist with fixture installation. The Millworker will provide a 29. Machine bolts and anchor bolts shall conform to ASTM A-307. Provide washers under head and nut LM manager to oversee installation. where bearing is against wood. Bolt holes in wood shall be 1/16" larger than bolt sizes. Nuts shall be 4. Installation: to 2. Insurance: As required by owner. Contact Managing Agent's representative for additional information tightened when placed and re-tightened before closing in. 4a. Do not start sheet metal work until substrate conditions are satisfactory to receive work. on insurance requirements and clarifications. Insurance to include the following unless otherwise 2. 2h. Solid block under all beams and posts to provide continuous support to foundation or post below. q g (2) Day Laborers for a total of (2) days to assist with product delivery and display. 4b. Protect dissimilar metals subject to galvanic corrosion from contact with each other and from other specified by Managing Agent; surfaces which cause corrosion of metal. 3. 2 Carpenters through one week after construction completion to cid in store fixturing and 3. Standards: Comply with requirements of American Institute of Timber Construction (AITC), local 4c. Allow for movement of components without cousin buckling, failure of joint seals, undue stress on 2a. Provide comprehensive personal and public liability and ( ) P 9 P g product P 9 9. p p p y property damage insurance policies for authorities, and the conventional construction, provisions of the building code, unless detailed otherwise. fasteners or other detrimental effects, when subject to 100 year seasonal temperature ranges.Y 9 P delivery. 1 Y P 9 $5,000,000.00 or as required. 4d. Use concealed fasteners, continuous cleats, except where specifically approved by Architect. Will T. Contract Closeout4. Products: 4e. Hem exposed edges on underside 1/2". Provide. fire-retardant treated material for all framing, g, plywood plywood4f. Install sealants where re 2b. All liability policies shall name the following as "additional insured": 402x blockinlwood sleeers and haired UL tprevent water penetration. rM 1. Notify Owner and Architect when work has been substantially completed. Submit list of items to be sheathing. Each unit of fire-retardant material shall be marked with classification marking, or other 4g. Completed installation shall be free of rattles or noise due to thermal and air movement and wind ompg aninspection agency es. leted to Owner and Architect, who will review and supplement list with items considered to be testing itinacceptable to local authorities. O FITCH cwhistles. unacceptable based on a site action with the Contractor. incomplete or ins Kiehl's Since 1851 P P P 4b. Plywood to be 3/4" MOO EXT. 4c. Unless otherwise noted, all framing lumber shall be Douglas Fir and meet or exceed the following 5. Warranty provide ten (10) year warranty for correcting failure of metal flashing to resist penetration of 40 2. Final Cleaning: At completion of Work or prior to Owner move in, employ skilled workers for final commercial grades: Al Y Such policies shall provide that they may not be terminated until at least 10 days after written notice 9 water and damage from wind. IV M cleaning, include glass, glossy surfaces, floors, and finishes. Perform the work under this Section so as to i. Studs less than 10', lutes and blocking Standard or better. to the owner. All insurance costs to be included in price. P 9 Lo keep affected portions of the building and site neat, clean, and orderly. Upon completion of the workD. Saalanta and Cam"under this Section, remove immediate) all surplus materials, rubbish, and equipment associated with or ii. Joists, rafters, beams and posts, studs greater than 10' No.2. y Piii. 6x beams and posts No.1. 1. Scope of Work: Provide and install sealants and caulking as shown on the Drawings and as otherwise E. COOrdinatlon used in the performance of this work. Failure to perform such cleanup operations within 24 hours of 4d. Wood in contact with concrete shall be pressure treated Douglas Fir conforming to the AWPB LP-2 required to prevent water infiltration into building. 1. Coordinate the work of various trades. notice by the Architect or Managing Agent shall be considered adequate grounds for having the work done •NOW![ standard. Wood embedded in concrete or earth shall be pressure treated to the AWPB LP-22 standard. by others at the Contractor's expense. 4e. All lumber shall be air or kiln dried to a moisture content not less than 7% and not more than 19X 2. Products: 2. Cooperate with owner and Managing Agent when scheduling time and locations for deliveries, building 4f. Fasteners to be galvanized type at pressure treated wood; provide washers for nuts and bolts. 2a. Caulk: DAP or Tremco Acrylic Latex Caulking compound Primer and Backup: As recommended by access, and building facilities. Verify all work required to be performed on premium time; no extras will 3. Manuals: Provide Project record documents, material, finish data, o eration Instruction manuals, manufacturer, compatible with caulk and sealants. u be allowed. 1 P / 4g. Pressure treat all wood in roofing, concrete, or areas subject to moisture. P N warranties, and bonds at Project completion. Submit bound in 8 1/2" x 11" three-ring binder with durable 4h. All wood blocking to be fire retardant. 2b. Glazing Compound: By glazing manufacturer. plastic covers. Arrange in CSI format similar to Specifications. 4i. Nails shall be common wire. Where wood tends to split, replace member and pre-drill holes. 2c. Silicone Sealant: Dow Corning Corporate #790. M O 3. Do not disrupt operations in adjacent areas. 4j. Joists, hangers, metal connectors and other miscellaneous timber connectors shall be per Simpson 2d. Fire-rated Products: 30 4. The installer of each major unit of work shall inspect the substrate to receive the work and the 4• Instruction: Instruct Owner in operation, adjustment, and maintenance of equipment and systems, using Company, San Leandro, CA or equal. Nail or bolt at all pre-drilled holes, per manufacturers specifications. I. Flommadur E-473, high strength, nonshrink, inorganic filter at rigid assemblies. - 1 P operation and maintenance data as basis of instruction. ii. Flammadur A-107, water based, non-toxic caulk at flexible assemblies. O conditions shall be reported to the Contractor and work shall halt until any unsatisfactory conditions P 4k. Subfloor plywood sheathing to be APA Sturdifloor, 3/4" thick, unless noted otherwise. O have been corrected. iii. Minimum F and T ratings: to match fire-rating of assembly being penetrated (1 hour min.). 5. Warranty of Construction: B. Finish Carpentry and M ork Available through: Flammadur Corporation, P.O. Box 2731, La Jolla, CA 92038, (858) 551-1236. 0 5e. The Contractor shall warrant that the work performed under this contract conforms to the contract 2e. Butyl Sealant: Tremco or approved equal. T 1. Scope of Work: Finish carpentry and millwork includes carpentry work that is exposed to view, is F. Conflicts requirements and is free of any defects of equipment, materials, design furnished, or workmanship by the 2f. Materials shall be free from impurities and defects and shall be the products of one manufacturer �� O non-structural and which is not specified as part of other sections. 1. Do not scale drawings, written dimensions govern. Contractor or any of his subcontractors or suppliers. insofar as practical. All materials shall be compatible for use with the materials and surfaces with which Ma 6 5b. Such warranty shall continue for a period of one year, in the case of floshing's and sky fights ten they are in contact. r ELJO 2. Verify dimensions and conditions at jobsite. years, and in the case of waterproofing and roofing, two years, from the date of final acceptance of the 2• Standards: Finish carpentry and millwork shall conform to AN, 'Architectural Woodwork Quality 1A LIL rn work. Under this warranty, the Contractor shall remedy at his own expense any such failure or defect in Standards, Custom Grade, typical. 3. Installation: •.... 3. Notify Architect of conflicts or discrepancies in the Contract Documents, before proceeding with the Work. 3a. Surfaces to receive sealant or caulk shall be in accordance with the manufacturers recommendations � ' A Work. Should a conflict occur in or between the Drawings and the Specifications, the Contractor shall Sc. Manufacturer3. Certification: The millwork produced as part of this work is expected to be of the highest possible craft = Manufacturer's guarantees or warranties still in effect shall be given to the Owner at the expiration of and shall be completely dry and cleaned of all dirt, dust, mortar, oil and other foreign matter that would _ ■ V and quality. The referenced quality codes and standards ore to be considered the minimum acceptable V comply with the Architect's interpretation. the guarantee period specified above. impair the product installation or adherence. y standards. All exposed finish wood paneling or cladding is to meet the surface burning characteristics of 3b. Sealant or caulk shall be applied by pressure gun equipped with proper sized nozzle to provide a � W ASTME-84, class 1 materials, with Flame spread index not to exceed 25. C* � O W G. Field F- DMSION TWO - SITEWORK / DEMOLITION continuous, smooth, solid bead, filing all voids and joints. Where using pressure gun is impractical, proper Provide field engineering services as required; establish grades, lines and levels by use of recognized 4. Products: hand tools shall be used to produce similar results. Feathering joints will not be allowed. engineering survey practices. Locate and protect control and reference points. a Selective Dern0�tion 4a. Trim and Moldings: Premium Grade, clear, kiln-dried, plain-sawn, S4S, AN grade: Premium Stock 3c. Sealed joints on flush surfaces and at internal corners shall e neatly filled and fully pointed with Roo CA V) 0 V) se profiles only as indicated on Drawings. Coordinate with Architect concerning cost and availability. tools designed for such purposes. All exposed sealant shall free of wrinkles and uniformly smooth. 1. Comply with applicable local, state, and federal codes and regulations pertaining to safety of persons, Areas not to be sealed and areas adjacent to those to be sealed shall be protected by masking from H. Periodic Cleaning and Protection property and environmental protection. stains, marks, or other damage. Finishes: 1. Remove debris caused by or resulting from operations as Work progresses. 5. 3d. Seal penetrations of fire-rated wall or floor-ceiling assemblies with fire-rated sealants or caulk, as 5e. Finger-jointed paint hardware, shop primed, at opaque finish. ® ' 2. Remove existing conditions as shown on Plans, taking care to protect adjacent improvements to appropriate, to maintain fire rating of total assembly. Install fire rated products in strict accordance with Apply protective 9 q P 9 y q Y 5b. Solid hardwood at transparent finish. 2. Alecovering as qu installed work where required to protect from damage or deterioration. remain. If the Contractor has an question on the extent of items to remain, he shall notify the Architect manufacturers instructions. t Maintain installed work as required through the remainder of the construction period to ensure and request a clarification before proceeding. 5c. Opaque Paint Finished Wood: Finger-jointed paint hardware or super refined MDF at interior, as noted /' on drawings. Fill all nail and screwholes, sandpaper all finished wood surfaces to produce a uniformly V operability at project completion. 4. Schedule: smooth surface. 3. Provide bracing and support as required to maintain structural integrity of portions of existing building 4a. Exterior and interior joints in masonry, including control joints: Silicone sealant. 5d. Wood veneer or Plastic-Laminate-Finished Wood: Custom Grade. 3. Take all reasonable precautions during the duration of the work to avoid damage or deleterious to remain. 46. Exterior and interior joints at perimeter of storefronts: Silicone sealant. ®®e.,® exposure to the wohf rk from unprotected storage, theft, vandalism, and improper shipping or handling. 5e. Duraflake FR: The corestock and/or substrate for all interior finish of architectural paneling requiring a 4c. Typical interior joints and seams a abutting and adjacent materials: Acry is-latex caulking compound. �� 4. Coordinate utilityInterruptions if necessary, with utility company, local authorities, Managing Agent, and Class I or II Fire Rating shall be Duraflake FR (Fire-Rated Particalboard) as manufactured by the Duraflake 4d. Joints in exterior flashing: But sealant. P Y Y P Y. 9 9 9 9� N L Cutting wild Patahtng neighboring properties. Provide temporary services if required. Division of Willamette Industries, Inc., Albany, Oregon, or approved equal, meeting Underwriter's 4e. Penetrations at fire-roted assemblies: Fire-rated rigid and/or flexible products as specified above. $ C E1851 1. Cut and fit components for alteration of existing work and installation of new work. Patch Laboratories, Inc., Std. Tests for surface burning characteristics of building materials (UL 723). disturbed areas to match adjacent materials and finishes. Cutting holes in Managing Agent installed 5. Asbestos: DIVISION EIGHT - DOORS AND WSDOWS floor, slabs, walls or roof is prohibited unless written approval is provided by the Managing Agent. 5a. If existing materials ore known to contain asbestos, remove, handle, store, and dispose of as required 6. Installation: by the Environmental Protection Agency, OSHA, and all other applicable Codes and ordinances. 6a. All millwork to be installed plumb and level; provide all necessary blocking and backing support A. Steel Doors and Frames 2. Penetrations in existingflooring must be approved b the Architect and Owner prior to execution. 5b. If existing materials are suspected of containing asbestos, notify the Architect and do not proceed material. 9 PP Y P 1. Scope of Work: Provide and install steel doors and frames as indicated and scheduled in Drawings. See with removal and disposal until directed by the Architect. 6b. Scribe and cut work to fit adjoining work and refinish cut surfaces or repair damaged finish at cuts. Finish Hardware section below for related work. I Cod" and Standards 6c. Paint or stain as specified in Division 9. See Paint Schedule for color selections. 6. Provide all necessary temporary enclosures, barricades and fences to adequately protect persons from 6d. Ease all exposed edges of interior millwork; set all finish nails for putty stopping. Hammer marks, 1. Comply with Code requirements for construction. Inform Architect of discrepancies observed or noted 2. Standards: by others. possible injury due to demolition operations. marred surfaces or edges are not acceptable.6e. Provide millwork in lengths as long as available. Where joints are unavoidable, scarf such joints and 20. Doors and frames shall comply with the Steel Door Institute 'Recommended Specifications-Standard 2. Com with standards referenced, except when more stringent requirements are required b Code. The 7. Items to be salvaged shall be removed in the most careful manner possible to avoid damages. stagger locations of joints on adjacent pieces. Steel Doors and Frames (SDI 100) and as herein specified. Comply P 9 q q y 6f. Machine finish edges on all MDF. 2b. Where fire-rated assemblies are indicated or required, provide fire-rated door and frame assemblies c date of the standard is that in effect as of the date on the drawings, except when otherwise indicated. 8• See Drawings for additional requirements related to demolition work. 6g. Any exposed surfaces showing tool marks, bruises or imperfections of any sort shall be rejected. that comply with NFPA 80 'Standard for Fire Doors and Windows' and have been tested, listed and labeled z 6h. Provide late joint MDF installation, typical. Glue and screw MDF at ends. in accordance with ASTM E152 by an independent testing and inspection agency acceptable to the local W 3. Contractor to comply with all Managing Agent requirements. C. authorities. Fn B. Site Utsfi" z K T" v � See engineering drawings for removal and re-use of any utilities and related equipment. 1. Scope of Work: The Work that includes the furnishing and installing of casework as shown on the 3. Submittals: Provide shop drawings of all steel doors and frames for Owner's approval prior to � z Provide testing as required by Specifications and by applicable codes. Contractor to verify all required Drawings and specified herein. Accurate field verification of dimensions is the responsibility of the casework fabrication. D 6 special inspection end deputy inspection prior to start of construction. DIVISION THREE - CONCRETE (Not Used) manufacturer. Z 4. Products: 2 L. Parmlts DIVISION FOUR - MASONRY 2. Standards: Casework shall be fabricated and installed in accordance with the standards established in 40. Acceptable manufacturers for steel doors and frames include Kowneer Corporation, Steelcraft, or Contractor shall obtain all permits necessary for completion of work. the AN 'Architectural Woodwork Quality Standards'; Custom Grade; flush overlay type. approved equal. A. Brick 4b. Door faces to be 16 gauge galvanized steel sheets, mill phosphatized. e A rn 3 N E 1. When new brick is required. Contractor to match existing adjacent bricks in color, size, etc. 3. Certification: AN certificate is not required; Owner reserves the right to contact AN for certification if 4c. Frames to be cold rolled steel, 14 gauge (min.) for exterior walls, 16 gauge (min.) for interior wells, I � � � M. Work by Others a 9 1 quality is questionable. galvanized. Corners to be mitered and welded. Except on weatherstripped frames, drill stops to receive 3 !0 m oe Contact the Managing Agent for work required to be performed by their specified subcontractors. I silencers on strike jamb of single swing frames and 2 silencers on heads of double swing frames. J O" n M rn 2. All existing brick to remain to be repainted with nonshrinking grout (color to match existing) and q. Products: 4d. Supports end anchors to be 18 gauge (min.) galvanized sheet steel. E N o N. Item Provide! by Owner sealed (sealant to have a flat finish). 4a. Material: 3/4" Medium Density Fiberboard; finish varies, see Finish Materials Schedule. 4e. Steel door and frame units to be rigid, neat in appearance and free from defects, warp or buckle. J Oco of Q a The following items shall be furnished by the Owner and installed by the Contractor. (Contractor shall DIVISION FIVE - METALS 4b. Adhesive: Phenol, resorcinol, or melamine base, FS MMM-A-181-b; type, grade and class best suited Field assemble. V mai+ provide Owner with ordering requirements): for the intended use. 4f. Exposed screws and bolts to have countersunk flat Phillips heads. a A .0 m L A. Miscellaneous Matti 4c. Hardware: 4g. Doors and frames to be prepared to receive mortised and concealed hardware in accordance with I. All light fixtures. Finish at exposed hardware: zinc, steel and stainless steel Hardware Schedule and templates provided by the hardware supplier. 1. Scope of Work: Provide and install of miscellaneous metal work as shown in the Drawings and specified Pulls: Verify with Architect. 4h. Pairs of doors to be provided with astragal at meeting stiles. Attached in field if specified. 72 (8 L) a ii. All metal / wood storage shelving. m herein. Hinges: Concealed European e, HAFELE or equal. 4i. Doors and frames to be factor rimed with one coat of rimer. W t n iii. (Consult with Owner for additional items.) 9 P q y P P •- r v Shelf supports: 5mm diameter chrome shelf pins with tilt prevention. J Z Go O. 2. Products: Drawer slides: Side mounted, full extension type, heavy duty, white. 5. Installation: a 0)2a. Fasteners, anchors, inserts, plugs, and like items required for the instollotion of products shown on 5o. Set frames accurately in position, plumbed, aligned and braced securely until permanent anchors are " o 1. Contractor shall review and approve submittals prior to submitting to the Owner for approval. the Drawings or otherwise specified shall be galvanized iron or stainless steel. 5. Fabrication: set. After wall construction is completed remove temporary braces and spreaders leaving surfaces smooth W w I v 1a. Inform Architect in writing at the time of submission of any proposed deviations from requirements 2b. Fasteners exposed to weather shall be hot-dipped galvanized or stainless steel only. Back prime all 5a. Make job measurements as required for proper fabrication of the work. and undamaged. Install fire-rated frames in accordance with NEPA Standard 80. N - of the Contract Documents. metals. 5b. Provide shop drawings of all casework for approval by Architect, prior to fabrication. 5b. Fit doors accurately in frames. Place fire-rated doors within clearances as specified in NFPA Standard 4i W E F 1b. Submittal by the Contractor represents that field measurements, field construction criteria, materials, 5c. Work Countertops: 0.050 inch high-pressure plastic laminate on 3/4" plywood; use marine grade 80• J catalog numbers, and similar data have been determined by Contractor and that each has been checked 3. Installation: Miscellaneous metal items shall be installed in accordance with the arrangements shown on plywood at all counters at wet areas, see Plastic Laminate Schedule below for finishes. 5c. Immediately after erection, sand smooth any rusted or damaged areas of prime coat and apply touch and coordinated with requirements. the Drawings and per standard construction practice. 5d. Adjustable shelves shall be supported by chrome shelf pins adjustable at 1-1/2" in 5mm system holes up of compatible air-drying primer, leaving doors ready for finish painting. n W 1c. Review of submittals shall be for design concept only and shall not be constructed as approving 5d. See Painting section of Division 9 for finishing requirements. r_ departures from Contract Documents. B. Ornamental Metal drilled in cabinet ends. Unless otherwise notes, all shelves to be 3/4" MDF with solid paint grade 1-1/2" lip for strength. 5e. Check and adjust operating finish hardware items, leaving doors and frames undamaged and in O complete and proper operating condition. 1. Submittals: Provide shop drawings for all miscellaneous metol items, prior to fabrication. yu 2. Product Data: 5f. Rehang or replace doors which do not swing or operate freely. Protect doors after installation to 6. Installation: M Provide for each stock-manufactured item. 1 2aensure they will be without damage or deterioration at time of completion. FM • 2b. Submit two copies; indicate item to be used where data for more than one product is indicated. 2 Products: Ornamental metal items to be custom fabricated as shown in the Drawings; see architectural 6a. Install cabinetwork plumb and level. Shim as necessary with concealed shims. Accurately scribe and W w details. closely fit all faceplates, filler strips, and trim strips to irregularities of adjacent surfaces. B. Wood Doors and Frames 6b. Fasten cabinets to floor at toe space and elsewhere at 24 inches on center maximum. � `O 3. Shop Drawings: C. LI ht GaY a Metal Framl 1. Scope of Work: Provide and install wood doors and frames as indicated and scheduled in Drawings. See 9 9 6c. Secure cabinets to walls with screws penetrating studs or blocking at least a inches. d 3a. Provide for custom-fabricated products and products not fully identified by product data. Finish Hardware section below for related work. ■ ■ 6d. After installation, touch up shop applied finishes to restore damaged or soiled areas, wipe finished 3b. Submit three shop drawings copies for Architect to process and retain one copy for the project file. 1. Scope of Work: Furnish and install light gouge metol framing as shown on the Drawings, including = Y P 9 9 9 9 9 9 surfaces to remove marks of handling, and leave in perfect condition. i punched channel studs, tracks, and 'C' shaped assts and furring. 2. Standards: P P 1 9• 6e. Casework shall be protected to ensure that work will be done without damage or deterioration at time � O 4. Samples: Provide two samples of each exposed finish, minimum dimension 6 of acceptance. 2a. Wood Sliding Door System: Comply with 'Architectural Woodwork Quality Standards' (AN). >- P. Construction Posits" 2. Standards: At fire-rated assemblies, provide framing units approved by the local authorities for the 6f. Install hardware and adjust for proper alignment and operation. 3 rating required. 6g. Any exposed surfaces showing tool marks, bruises or imperfections of any sort shall be rejected. 3. Submittals: Provide shop drawings for wood sliding door system for Architect's approval prior to A/ Provide temporary facilities as required for completion of work. Existing facilities may be used as allowed 6h. At wet areas, completely seal all plastic laminate edges to prevent water penetration. fabrication. 1i� m by Managing Agent. Clean all facilities daily or as required. 3. System Components: qIL W 3a. Acceptable manufacturers include Ceco Corporation, Inryco-Milcor, U.S. Gypsum, or approved equal. DIVISION SEVEN - THERMAL AND MOISTURE PROTECTION 4. Products: 3b. With each type of framing required, provide manufacturer's standard steel tracks, blocking, lintels, clip 4a. Wood doors noted to receive paint finish to be shop primed with one coat of wood primer as specified angles, shoes, reinforcements, fasteners, and accessories as recommended by the manufacturer for the A. Roofing in Division 9. intended application. 1. Contractor to survey existing conditions at all roof leak locations. Provide cost effective solutions to 4b. Prefit and premachine wood doors at factory for mortised and concealed hardware, in accordance with 3c. All framing components to have galvanized finish. repair roof at each location. the hardware schedule and templates provided by the hardware supplier. ��➢ A/� 3d. Channel studs to be load-bearing, 16 gauge, 6", unless otherwise noted on Drawings herein. (' 3e. Joists to be 25 gouge, 6", unless otherwise noted on Drawings. B. Thermal Menllatl0n 5. Installation: C_ f� 9 9 9 BLAIR S. Sa. Condition doors to averse prevailing humidity in installation areas prior to hanging. R. Material and Equipment 3f. Attach components by welding, bolting, or screw fasteners as recommended by manufacturer. Wire 1. Scope of Work: Provide and install as shown on the Drawings and as required at any roof penetrations 5b. See Painting section in Division 9 for finishing requirements. P �� LEACH e6 1. Materials and equipment shall be new and of type intended for usage indicated. Like components tying of framing components is not permitted. and as directed by Owner and specified herein. � shall be by one manufacturer and component parts shall be interchangeable. 4. Installation: C. Finish Hardware 2. Standards: 4a. Install continuous tracks sized to match studs. Secure tracks as recommended b manufacturer; do 2. Workmanship: Com with industry standards, except when more stringent tolerances are required b y 20. For new rigid insulation of roofs, cam with Factor Mutual Standard 4450 4470 for Class 1 1-90 a Scope a Work: Provide and install finish hardware as indicated in the Drawings t and hardware schedule, l/5/l5 Comply Y P 9 q Y 9 comply Y / / SCOTT60.34 'AZ not exceed 24" o.c. spacing for nail or power driven fasteners, or 16" o.c. for other types of attachments. and as specified herein; coordinate with door suppliers for premachining of doors to receive mortised or � the Contract Documents. Windstorm Classification; refer nt FM Approval Guide for details. Provide manufacturer's standard 20 year ;A by;q O'er Provide fasteners at corners and ends of tracks. concealed hardware. limited R-value retention warranty. 3. Perform Work b persons qualified to produce workmanship of special quality. 4b. Set studs plumb, except as needed for diagonal bracing or required for non-plumb walls or warped `�� Y P q P P P a Y 2b. Flame spread/Smoke Developed Ratings: � surfaces. Where stud system abuts structural columns and walls (including masonry walls), anchor ends of 2. Standards: Hardware for fire-rated openings to comply with NFPA Standard 80 and the requirements of G Op O� I. Insulation materials, including facings, such as vapor barriers or breather papers installed within 1' 4. Secure products in lace with positive anchorage devices designed and sized to withstand stresses, stiffeners to supporting structure. the local authorities. Provide hardware tested and listed by UL of FM for types and sizes of doors and P P P 9 9 floor-ceiling assemblies, roof-ceiling assemblies, walls, attics or crawl spaces, shall have a flame spread vibration, and rocking. Allow for expansion and building movement as required. 4c. Install supplementary framing, blocking, and bracing, where required to support fixtures, equipment, frames required. P 9 9 rating of 25 or less and o smoke developed rating of 450 or less. accessories, trim and similar work requiring attachment to walls or ceilings. ii. Contractor shall provide documentation as required by local inspection agency to verify compliance DATE: SHEET: 5. Manufactured items: transport, handle, store, protect, and install manufactured items in strict 4d. Secure studs at top and bottom tracks at both inside and outside flanges. Frame well openings larger 3. Submittals: 12/23/14 P P with the above referenced standards. accordance with manufacturer's recommendations. than 2'-0" square with double stud at each jamb or frame, unless more than two studs are 3a. Submit final hardware schedule for Architect's approval prior to door machining; coordinate hardware SCALE:recommended by manufacturer. Install tracks and jack studs, at same spacing as full height wall studs, 3. Products: with doors, frames, and related work to ensure proper size, thickness, hand, function and finish of AS NOTED 6. Should conflict exist between construction and manufacturer's instructions, notify Architect prior to above and below well openings. 3a. Exterior Walls: Foil faced fiberglass batt insulation, Owens-Corning or equal, with R value of 19, typical. hardware. DRAWN BY: w ..L proceeding. 4e. Install horizontal stiffeners in stud system spaced vertically at not more than 4"-6" o.c. 3b. Provide manufacturer's catalog cuts of any item of hardware which is proposed as a substitution to N.R. spi p g. 3b. Install wall and raised roof area batt insulation per manufacturer's recommendations. the items s stifled in the Hardware Schedule below. 0A 4f. Install joists level and plumb, with not less than 1-1/2" end bearing. Reinforce ends as recommended 3c. Bathroom Walls: Foil faced fiberglass batt insulation, Owens-Corning or equal, with R value of 11, typical. P PRO1ECr No.: t� by manufacturer. Secure joist to interior support systems to prevent lateral movement of bottom flange. 32O1O34Q8 LLS -- SPECIFICATIONS ABBREVIATIONS COPYRIGHT NOTICE: These drawings and specifications aro copyrighted and ander ec copyright protection as an 17 u.S.C. As work" under sec. ce be the copyright act, on uincl es amended december 1990. The profit/ion includes, without limitation, the overall form, arrangement and composition of spans, and elements of the design. DIVISION EIGHT - DOORS AND WIDOW$ (Continued) 3. Installation: C. Restroom Accessories Under such protection, unauthorized use of these 3a. Examine areas to receive wood flooringano conditions under which it will be installed. Do not A C AIR CONDITIONING MACH. MACHINE proceed drawings and building may result in cessation of 4. Products: 1. Scope of Work: Contractor to provide and install restroom accessor'es as shown in the Drawings and A.F. ADJUSTABLE MAX. MAXIMUM nnatruetion, evading se zu e, and/or maraca n with installation until conditions are satisfactory to per manufacturer's recommendations including monetary liability. 40. Obtain each type of hardware from only one manufacturer. y P g specified herein. A.F.F. ABOVE FINISHED FLOOR MTL. METAL recommended slab moisture receive work content. Le Hardware should comply with applicable building codes and with applicable ADA access requirements. 3b. Install vapor barrier over new and existing concrete slab subfloors; la ALUM. ALUMINUM MIN. MINIMUM Lever hardware or equal with Slbf maximum operating force shall be used on doors. P 9 p joints at least 6" and seal 2. Products: ARCH. ARCHITECTURAL N.I.C. NOT IN CONTRACT 4c. Drawings show direction of swing or hand of each door leaf; furnish hardware for using compatible caulking. g g proper operation of 20. All restroom accessories are by Bobrick and American Specialties. BD. BOARD N.T.S. NOT TO SCALE doors as shown. 3c. New concrete subfloors to be fully cured before installation of wood flooring and should be tested for 2b. Refer to Plumbing and Accessory Schedule on Sheet A5.1 for details. BLK. BLOCK 0/ OVER 4d. Furnish screws for installation of all hardware items; provide Phillips flat head screws, LION. content. ON. Finish at BLKG. BLOCKING O.D. OUTSIDE DIAMETER exposed screws to match hardware finish. 3d. Install sleepers, flooring and accessories in accordance with manufacturer's recommendations. See 3. Installation: C.G. CORNER GUARD OFC. OFFICE 4e. Hinges: Provide number of hinges indicated, but not less than 3 hinges Drawings for running directions for flooring. 3a. Coordinate blocking requirements with framing installers to ensure adequate support 9 g g per door leaf for doors 90" or 9 q g q apart for all accessories. CLG. CEILING OPP. OPPOSITE less in height, and one additional hinge for each additional 30" of height. C. CMnft Tu 3b. Locations of accessories shown on Drawings comply with ADA accessibility requirements; do not COMP. COMPUTER P PROFILE 4f. Hinge pins: Provide as follows: relocate without Architects approval. CONC. CONCRETE PL PLASTIC LAMINATE Steel hinges: Steel pins. 1. Scope of Work: Provide and install ceramic tile, accessories as shown in the Drawings and specified DIA. DIAMETER PLYWD. PLYWOOD herein. Apply waterproof membrane between concrete and new tile work. D. EnWayes Lockers Exterior doors: Non-removable pins. DIM. DIMENSION QTY. QUANTITY Interior doors: Non-rising pins. 1. Scope of Work: Provide and install employee lockers as shown in the Drawings and specified Products: herein. DR. DOOR REF. REFERENCE Tips: Flat button and matching plug. 2. DTL. DETAIL RCP REFLECTED CEILING PLAN L I Em 4g. Locksets and Keys: All locksets to be 'Schlage'; no substitutions. Exit devices to be Van Duprin or 2b. Grout: Laticrete or equal, 42 platinum.2a. See Finish Plan A2.1 for details. 2. payee lockers are to be provided by the client. DWWI G. DRAWING REQ. REQUIRED approved equal. Levers pulls, cross bars, etc. to be mounted at 36" AFF, LION. Doors to be keyed using EA. EACH RM. ROOM Ye 9 2c. Waterproof membrane: equal m ti waterproofing sheet as manufactured by the Noble Company, 3. Installation: Install lockers per manufacturer's recommendations. Secure lockers at the floor and wall CS ELEC. ELECTRICAL R.O. ROUGH OPENING only.Schla 'Removable Core' system; all keys and cores to have visual key control; provide nickel silver keys 800.878.5788, or approved equal meeting the requirements of ANSI A118.10. required for secure anchorage structure. EQ. EQUAL SCHED. SCHEDULE only. Furnish 3 keys for each lock. q g F FIXTURE SHT. SHEET �I 4h. Strikes: Provide manufacturer's standard box strike for each latch or lock bolt with curved lip 3. Installation: E. Storne Rodes F.D. FLOOR DRAIN SIM. SIMILAR C/ extended to protect frame. Provide extended lip strikes where required to protect frame or trim from 3a. Examine areas to receive tile work, and conditions under which they will be installed. Do not proceed 1. Scope of Work: Install storage racks at Stockrooms as provided by client. F.F. FINISH FACE SF SPECIAL FINISHES / A damage from latch bolt. with installation until conditions are satisfactory to receive work. FLR. FLOOR SPEC. SPECIFICATION r / 4i. Closers: Size door closers in accordance with manufacturer's recommendations for size/weight of door, 3b. Install ceramic tile per TCA 'Tile Council of America' method F141-98 (thickset with reinforcing and 2, Installation: FT. FOOT OR FEET SPKR. SPEAKER exposure to weather and frequency of use. Closers to be painted to match adjacent door and trim finish cleavage membrane over wood substrate), as described in the 1998 Handbook for Ceramic Tile Installation. 2a. Install storagey racks as directed b the Owner. G GRAPHIC SQ. SQUARE at public areas. Control joints and cold joints should be addressed using Method EJ171. Fit floor tile neatly around all G.C. GENERAL CONTRACTOR S.S. SERVICE SINK 1 4'. Access-Free Manual Closers: Where manual closers are indicated for doors required to be handicapped 2b. See Sheet A2 for shelving count and layout. Verify locations in field prior to securing racks to floor O q aped floor penetrations and obstacles. and walls. GL. GLASS STD. STANDARD accessible, provide adjustable units complying with ANSI 117.1 provisions for door opening force and 3c. Grout joints to be minimum width suggested by manufacturer. G.W.B. GYPSUM WALL BOARD STL. STEEL delayed action closing. 3d. Apply clear matte sealer to all ceramic tile and grout areas after installation as recommended by tile DIVISION ELEVEN - EOUIPMENT GYP. GYPSUM T.B.D. TO BE DETERMINED 4k. Thresholds: If not specifically scheduled on Drawings, provide 'Pemko dark bronze anodized aluminum manufacturer. H HARDWARE TEL. TELEPHONE �\ M thresholds with oil rubbed bronze finish, not less than width of door frame, formed to accommodate D P HGT. HEIGHT TYP. TYPICAL r/ � � 1 attrtYlg A. Audio-Visual Equipment changes in floor elevation, with 1/2" maximum rise. Fabricate to accommodate door hardware and to fit H.V.A.C. HEATING, VENTILATING & AIR U.S. UNITED STATES L door frames. 1. Scope of Work: Provide and install all painting work as indicated in the Drawings and specified herein. 1. Coordinate all audio-visual low voltage and equipment requirements with Owners vendor. CONDITIONING V.I.F. VERIFY IN FIELD 4i. Provide continuous weatherstripping at the edge of every exterior door leaf and at all fire rated door INT. INTERIOR VT VINYL TILE ■� N framing assembles. 2. Submittals: Provide brushouts of oil paint colors/finishes for Architect's approval. 2. Install plasma screens within millwork units as detailed in the Drawings. Provide blocking and mounting J. BOX JUNCTION BOX WB WALL BASE hardware as required. LAM. LAMINATE WC. WALL COVERING 5. Hardware Schedule: (Note: see hardware schedule on Drawing Sheet Al). 3. Products: LAV. LAVATORY yy WITH 30. Products specified are b Benjamin Moore DIVISION TWELVE - FURNISHINGS D Vf p e y Jam oo a & Company. Substitution will not be accepted. See Painting LT. LIGHT WD. WOOD 6. Installation: Schedule on drawing A2.1 for types/colors. Paint products must comply with current State and local air JL WY1dow Treehnents1. Scope of Work: Provide and install window shades at locations indicated on Drawings. W/W/0 WEIGHT WITHOUT O 6a. Set all hardware items level, plumb and true to line and location. Adjust and reinforce the attachment quality standards for VOC emissions. substrate as required for proper installation and operation. 3b. All paint and coatings must be delivered to the job site in manufacturer's original containers. _ 6b. Set thresholds for exterior doors in full bed of butyl rubber or polyisobutylene mastic sealant. 3c. Commercial mildew wash formulated for removing exterior mildew/mold conditions. 2. Products: Sol-R-Shade, Architectural Series, Chain Operated. 6c. Where cutting or fitting is required to install hardware on surfaces which are to be painted or finished 3d. Product or paint additive to prevent further appearance of mildew/mold as recommended by and 2a. Shade Cloths: See Finish Plan for style and color per location. O O in the field, remove, store and reinstall hardware after finishing work is completed per Division 9. Do not compatible with the specified product. install surface mounted items until finishes have been completed on the substrate. 3. Installation: Install per manufacturer's specifications per location conditions. 6d. Clean adjacent surfaces soiled by hardware installation. 4. Installation: �� O 6e. Adjust and check all hardware items after installation a ensure proper operation or function of doors. 4a. Examine areas to receive painting materials and conditions under which they will be installed. Do not B Flyddrs and AeeessorlBs Replace items which cannot be adjusted to operate freely and smoothly as intended for the application. proceed with installation until conditions are satisfactory to receive work, per manufacturer's 1. Scope of Work: Instal. Owner provided furniture cnd accessories as indicated on Sheet A2. r ■ LJL recommendations. 4b. All paint shall be applied in a workman-like standard without visible defects or brush marks. Wherever DM$ION THRTEETI - SPECIAL CONSTRUCTION (Not Used) um DIVISION NINE - FINISHES possible, all corners shall be cut to an inside edge. Go M 4c. New plaster and other masonry surfaces shall not be primed until it has been determined that these DIVISION FOURTEEN - CONVEYING SYSTEMS (Not Used) A. Gypsum BOQd Lin Vsubstrates have dried sufficiently to safely accept paint. A reliable electronic moisture meter should be 1. Scope of Work: Furnish and install new gypsum board wall and ceiling finish as shown in the Drawings used to make this determination. Unacceptable moisture content should be reported to the Architect or DIVISION FIFTEEN - MECHANICAL and schedules, including installation of metal support systems where required, and including joint tape and his representative. Go to t UJ compound treatment. 4d. For existing masonry surfaces, remove all peeling g and scaling Ln a. O point to a sound substrate by hand See specifications in mechanical drawings for additional information. 2. Standards: scraping and/or high pressure spray equipment. Mildew and mold must be removed by scrubbing with a 2a. Conform to ASTM C754 and Gypsum Association GA-216 standards and recommendations. commercial mildew wash formulated for this purpose. All structural cracks and crevices must be filled with A. 1111 2b. Fire-rated Construction: Comply with Underwriter Laboratories certified fire tests and a licable code appropriate patching compounds. Old cracked and loose caulking is to be removed and replaced with a 1. Scope of Work: See Specifications in Mechanical Drawings. P Y pP high quality caulking compound. requirements. All gypsum board to be fire-roted. 4e. Paint exposed metal, metal doors and frames. Remove all existing paint to bare metal. Metal must be 2. Products: See Specifications in Mechanical Drawings. 3. Products: Acceptable Manufacturers include: clean, dry, and free of oil and grease; wipe bore metal with mineral spirits to remove any remaining oil ' film. Prime metal surfaces and material not indicated to be prefinished. 3. Installation: Install registers and thermostat according to locations given on the Architectural Drawings. t Metal Support Materials: 4f. Protect all surfaces not receiving paint from damage due to painting operations. Inform the Architect of any discrepancies between the Mechanical and the Architectural Drawings. /\ Chicago Metallic Corporation, United States Gypsum Company, 4g. Provide clearly labeled full cons of paint for the Owner, one gallon per color/finish.Gold Bond Building Products, 4h. Paint is to be installed as specified in Drawings. See finish schedule on Sheet A2.1 for details. EL Plush ig or approved equal. DIVISION TENTH - SPECIALTIES 1. Scope of Work: See Specifications in Plumbing and Fire Protection Drawings. ����•� Gypsum Board and Related Products: Georgia Pacific Corporation, A. Signage 2. Products: See Specifications in Plumbing and Fire Protection Drawings. United States Gypsum Company, 1. Scope of Work: Provide miscellaneous signage as shown on the Drawings and specified herein. S I N C E 1 8 5 1 Gold Bond Building Products, Coordinate installation of store name si nae at the storefront as shown on elevations with Owner'sDFVISIM - ELECTRICAL or approved equal. signae 3a. Metal framing and gypsum board ceiling systems: signage contractor. See specifications in electrical drawings for additional information. i. Conform to ASTM C840 and U.S. Gypsum Company SA-923 Section 1.3.4.4.: Direct A. Nk*o System Suspension System Erectionn specifications. specifications. 2. Submittals: Provide shop drawings of all signage for Architect's approval prior to fabrication. ii. Hot Channel System: Brace as required for lateral movement with #12 gouge wire, per 1. Scope of Work: Provide music system throughout the store sales area as shown on the Drawings and manufacturer's specification. 3. Signage Standards: specified herein. iii. Wall Partition Systems: see Division 5: Light Gauge Metal Framing. 3a. At all identification symbols, the geometric symbol shall be of a color and contrast distinctly different 3b. Gypsum Board Products: from the color and contrast of the door. 2. Products: Music system shall be provided by the Owner. Contractor to provide 10 GA. speaker wire and 3b. A permanent identification sign, including raised letters accompanied by Braille, shall be installed on shall provide labeling and termination as shown on the Drawings. I. Typical gypsum board to conform to ASTM C36; 5/8" thick, Type X, with tapered edges. P 9 9 the door at each sanitary facility. Signage must be mounted 60" minimum to centerline above finished ii. Water resistant gypsum board to conform to ASTM C630, 5/8" thick, Type X, with tapered �c edges. Provide at walls at all bathrooms, janitor areas, and where otherwise indicated on the Drawings. floor and 8" maximum from the edge of the strike side door jamb. 3. Installation: Music system supplier to provide complete and finished installation of store music system. a ill. Cement backerboard to be 1/2" thick Durock, or approved equal. 3c. Raised characters or symbols shall conform to the following: 3c. Ceiling Access Panels: I. Letters and numbers on the permanent identification sign shall be raised 1/32" minimum and shall IL Security % tw Z Braille. 2 B d G d b i t h if-seruppercase characters accompanied y Grade rae. I. Scope of Work: Provide and install ceiling access panels as shown on the Drawings and specified be sans 1. Scope of Work: Coordinate installation of store security system (consisting of ceiling mounted video Z herein. it. Raised characters or symbols shall be a minimum of 5/8" high and a maximum of 2" high. cameras and video recorder on a closed circuit tv system, see sheet A2.) to be supplied by Owners z ii. Products: Ceiling access panels to be U.L. listed, flush, L-DWC with grooved drywall bead for ill. Pictorial symbol signs (pictograms) shall be accompanied by the equivalent verbal description consultant. o application of joint compound over the flange as manufactured by Larsen's Manufacturing Company or placed directly below the pictogram. The border dimension of the pictogram shall be a minimum of 6" in z > approved equal. height. 2. Products: Security system shall be provided by Contractors sub-contractor. All security lines to be 3d. Contracted Grade 2 Braille shall be used on the permanent identification sign. Dots shall be 1/10" on category 6 cable. 3d. Accessories: center in each cell with 2/10" space between cells. Dots shall be raised a minimum of 1/40" above the I. Provide manufacturer's standard trim and accessories for gypsum board work, formed from background. 3. Installation: Contractor shall provide coordination as required with specified supplier for complete and is >` rn I N E galvanized steel unless otherwise noted. finished installation of store security system. r ' h 04 8 ii. All visible gypsum board edge conditions to receive metal edge trim U.S. Gypsum Series 200 or 3f. Characters and numbers on the permanent identification sign shall be sized according to the viewing �/ W m ao equal. All edges to be tapered and rounded. distance from which the are to be read. The minimum height is measured using on u a m rn q 9 P Y g g peer case X. Lower C. TeIspllsre Sy-to ") a 0) case characters are permitted. 0 o 0 dr 3e. Joint treatment materials: 3g. Characters and symbols shall contrast with their background, either light characters on a dark 1. Scope of Work: Provide and install telephone system as shown on the electrical drawings and specified C I. Joint treatment materials to conform with ASTM C475, and to manufacturer's recommendations for background or dark characters on a light background. herein. /� V Q the intended application. 2. Products: Telephone system to be supplied by Owner. All phone lines with the exception of the 3 lines [ L v m ii. For interior work, provide chemical hardening type joint compound for bedding and filling; vinyl 4. Products: for securityore to use RJ-11 type read mixed or powder) for topping. 4a. Store Identification Signage at Service Entries, to be provided b Contractor. Verify with Owner prior to jocks and to be labeled and terminated. All telephone lines to be category - x YP ( Y- P ) PP� 9• Y Y P 6 cable. o iii. Use special water resistant type joint compound at water resistant gypsum board areas. proceeding. Sign to say 'Kiehl•s Since 1851'. p ) e 4b. Signage at Sanitary Facilities, identification symbols to be located at the following locations: 3. Installation: Contractor shall provide coordination as required with specified supplier for complete and W r a 4. Installation: i. Doorways leading to men's sanitary facilities shall be identified by on equilateral triangle 1/4' thick finished installation of store telephone system. _J Z rn 4a. Comply with recommendations of gypsum board manufacturer for environmental condition before, with edges 12" long and a vertex pointing upward. rn during and after gypsum board installation. ii. Doorways leading to women's sanitary facilities shall be identified by a circle, 1/4" thick and 12" D' Deft Syudstil shim M m 4b. Cold weather protection: When outdoor temperatures are below 55 degrees F, maintain continuous in diameter. 1. Scope of Work: Coordinate installation of store data system to be supplied by Owners consultant. W _ v building working temperature of not less than 55 degree F for a minimum of 48 hours before, during and ill. Doorways into unisex sanitary facilities shall be identified by a circle 1/4" thick, 12" in diameter, � + after application of gypsum board and joint treatment materials. with a 1/4" thick triangle superimposed on the circle and within the 12" diameter. 2. Products: Data system shall be supplied by Owner. All data lines are to use RJ-45 jacks. All data lines t- 4c. Black iron metal support systems: (Note: all black iron installation to conform to local standards). 4c. Storefront Signage shall be furnished and installed by the Contractor's Graphic Designer. to be category 6 (UTP) cable and shall be labeled and terminated. J i. Secure hangers to structural support by connecting directly to structure wherever possible. Otherwise connect to inserts, clips or other anchorage devices or fasteners. 5. Installation: 3. Installation: Contractor shall provide coordination as required with specified supplier for complete and t0 C ii. Space main runners at 4-0 o.c., maximum, and space hangers at 4•-0" o.c., maximum, along 5a. For sanitary facility and store identification signage at service entries, install as recommended by finished installation of store data system. C runners, unless otherwise noted. Level main runners to a tolerance of 1.4" in 12'-0". Wire tie or clip manufacturer, centered on doors. I - ,0 furring members to main runners and to other structural supports. 51d. Mounting heights/locations: v iii. Attach perimeter wall track or angle wherever support system meets vertical surfaces. V! i. For service entry doors, top of sign to be 5'-6" above the finished floor. iv. Space furring members at 16" o.c., minimum, unless otherwise noted. Install auxiliary framing at W m openings for light fixtures and similar items, as required to support both gypsum board assembly and ii. For sanitary facility doors, height shall be 60' above the finished floor to the centerline of the sign and 8" maximum from the edge of the strike side door jamb. other work. iii. For sanitary facility wall-mounted signage, sign shall be installed on the wall space on the latch ` 4d. Gypsum board: side of the door. Where there is no wall space on the latch side, the sign shall be placed on the nearest ■ • CL L Install gypsum board in strict accordance with manufacturer's recommendations and per ASTM adjacent wall, preferably on the right. Mounting location shall be determined so that a person C84D and GA-216. on may = Y H. Apply gypsum board to supports with screws; space fasteners in accordance with referenced approach within 3" of the signage without encountering protruding objects or standing within the swing of Q p standards. the door. iii. Where indicated to receive paint finish, take special care with joints and fasteners so they are �•/ undetectable when pointed. Smooth wall finish below crown molding at sales areas and in storage rooms, 5c. Contractor shall provide coordination as required with Owner's storefront signage contractor for 3 at offices, and bathrooms. complete and finished installation of all storefront signage. Z 4e. Ceiling Access Panels: 5d. Signage shall comply with guidelines set forth in tenant criteria manual. Q I. Verify ceiling openings are dimensioned correctly to receive doors. Re EXttnglrellers ii. Install ceiling access doors in accordance with manufacturer's written instruction. iii. Tape-in fiberglass access panels. 1. Scope of Work: Provide and install fire extinguishers as required by local jurisdiction and specified 4f. Accessories: herein. I. Install metal corner beads at all external corners of gypsum board work. C ]� ii. Install metal edge trim wherever edge of gypsum board would otherwise be exposed. 2. Products: Unless otherwise required by local jurisdiction , fire extinguishers are to be multi-purpose dry iii. Install L-type trim wherever gypsum board is tightly abutted to other work. chemical type (A/B/C), 6 lbs. nominal capacity (minimum), with heavy duty steel cylinder, visual pressure 1S BLAIRS. f 4g. Finishing: gauge, upright squeeze grip operation, approved to -65 degrees. Acceptable manufacturers include: 44IQ� LEACH i. Apply joint treatment compound at gypsum board joints, flanges of trim, accessories, penetrations, J.L. Industries 612.835.6850. fastener heads, surfaces defects and elsewhere as required to prepare work for finishes. Prefill open joints Larsen's Manufacturing Company 800.527.7367. and rounded or beveled edges per manufacturer's recommendations. Apply joint tape at all gypsum board Modem Metal Products 507.451.7114. joints, except where trim accessories ore indicated. or approved equal. SCOTTSDALE,AZ �S ii. Apply joint compound in three coats, not including prefill. Sand before and after last coat. ill. In areas to receive ceramic tile finish, using organic adhesive, tape joints and apply 4" wide coat 3. Installation: J.9 6034 GO'ti of joint compound. 3a. Confirm number of extinguishers required and acceptable mounting locations with local authorities; provide as required. Extinguishers in sales (public) areas to be located out of view to the general public; OF Q B. Wood Fklortil0 review proposed locations with Architect prior to installation. 1. Scope of Work: Patch and repair existing slab as required to receive new flooring. 3b. Install fire extinguishers as recommended by manufacturer, using manufacturer's standard wall brackets, securely fastened to structure, square and plumb. Height of extinguisher above floor shall be 54" DATE: SHEET: 2/23/14 2. Products: (maximum) to top of unit, unless otherwise required by local governing authorities. SP2 �o2a. 1/2" x 4" transition strips/reducers to match new wood floor. 3c. Check extinguishers for proper charge and operation. Remove and replace damaged, defective or under SCALE:E: AS NOTED 2b. Vapor barrier to be 6 mil. polyethylene. charged units. ... DRAWN W. W N.R. zoo PRWECT NI 320103448 RESPONSIBILITY SCHEDULE GENERAL NOTES COPYRIGHT NOTICE: These drawings and specifications am copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, on Incl. As es 'mended december a ame The protection Includes, without limitation, the overall form, arrangement and RESPONSIBLE PARTIES 1 WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING: 5 PROVIDE A MINIMUM OF TWO 2A IOBC CLASSIFICATION FIRE EXTINGUISHER WITHIN 75' 2 ADMINISTRATION: PREPARE AGENDA, CONDUCT MEETINGS, AND COPY PARTIES AFFECTED composition of spaces, and elements of the design. D=DESIGN S=SUPPLIED 1=IMPLEMENT INSTALL Under such protection, unauthorized use of these / TRAVEL DISTANCE FOR EACH 6000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. BY DECISION MADE AT THE MEETINGS. drawings and specifications may result in ceasation of ul A THESE GENERAL NOTES UNLESS NOTED OTHERWISE ON PLANS OR SPECIFICATIONS. (U.F.C. ARTICLE 10. DIVISION III, U.F.C. STANDARDS 10-1 AND C.A.C. T-19, SECTIONS 3.29) construction, building seizure., and/or monetary liability. x o a INCLUDES NO LESS THAN 12 INSTALLED AT THE DIRECTION OF THE FIRE INSPECTOR 3 NOTIFICATION: GIVE PARTICIPANTS NO FEWER THAN THREE (3) DAYS NOTICE OF MEETINGS Y oZ B WORK TO COMPLY WITH THE FOLLOWING: NOT REGULARLY SCHEDULED. << n w 0 > o Ox 6 BUILDING OCCUPANT TO SECURE PERMITS REQUIRED BY THE FIRE DEPARTMENT FROM THE w i- w= _ 'z ?0 00 0 0 o CE 0 0 o a o 2014 OREGON STRUCTURAL SPECIALTY CODE FIRE PREVENTION BUREAU PRIOR TO OCCUPYING THIS BUILDING. FOLLOWING MAXIMUM FLAME 4 OWNER AND ARCHITECT: WILL ATTEND EACH PROJECT MEETING. ARCHITECT WILL Z Z w m 0 o 0 =z _1 z o z Z z v z Z z ow z w z 2014 OREGON MECHANICAL SPECIALTY CODE SPREAD CLASSIFICATION FOR FINISH ASCERTAIN THAT WORK IS EXPEDITED CONSISTENT WITH CONTRACT DOCUMENTS AND 0 00 0 o a a w � ¢ a vl in ?y REMARKS 2011 OREGON PLUMBING SPECIALTY CODE CONSTRUCTION SCHEDULE. DEIAOLJ7ION 2011 OREGON CHAPTER ELECTRICAL SPCIALTY CODE S7 ALL PREAD CLASSIC WFATNLLS ANFlNICSEING HUM FINIS SS SHALL BEAR THE FOLLOWING MAXIMUM FLAME CONTRACT CLOSE—OUT: — TEMP. WINDOW GRAPHICS D/S/I 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE 1 FILE FOLLOWING WITH OWNER PRIOR TO FINAL PAYMENT' _tJUILl 2007 PORTLAND FIRE CODE ENCLOSED VERTICAL — CLASS I F.S_ 0-25 — TEMP. BARRICADE GRAPHICS D/S/I G.C. DIATE_Y UPON COMPLET10N OTHER EXITWAYS — CLASS II F.S. 26-75 — TEMPORARY LIGHTING D/S/I AND ANY OTHER APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS. ROOMS OR AREAS — CLASS III F.S. 76-200 A WARRANTIES: AREQUIRED UNDER CONTRACT DOCUMENTS. E CONSTRUCTION C BUILDING CODE REQUIREMENTS TAKE PRECEDENCE OVER THE DRAWINGS AND IT SHALL 8 BUILDING NUMBER OR ADDRESS SHALL BE EASILY VISIBLE AND LEGIBLE FROM THE STREET B LIENS: RELEASE OR WAIVER AS REQUIRED UNDER CONTRACT DOCUMENTS. L BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT OR ROAD FRONTING THE PROPERTY. LOCATE AS DIRECTED BY THE FIRE INSPECTOR. NUMBERS C BONDS AND SPECIAL SERVICES MAINTENANCE CONTRACT: AS SPECIFIED. EXECUTED MECHANICAL S/I D D ANY DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THE CODE AND THE DRAWINGS. SHALL BE 8" HELVITICA FOAM CORE PAINTED IN CONTRASTING COLOR. BY EACH SUBCONTRACTOR, MANUFACTURER AND SUPPLIER AS APPLICABLE. to ELECTRICAL S/I D D — LIGHTING FIXTURES I S D D/S D SEPARATE PLANS FOR ELECTRICAL, PLUMBING AND HVAC SHALL BE SUBMITTED TO 9 BUILDING OR I PORTION . DESIGNATED SHALL COMPLY WITH U.F.C. ARTICLE 81 FOR 2 RECORDED DRAWING. KEEP AMARK—UP,AND DEVIATIONS SET OF BLUE LINE DRAWINGS ON LU THE RESPECTIVE BUILDING DEPARTMENTS FOR APPROVALS AND PERMITS. HIGH PILED COMBUSTIBLE STOCK. BUILDING OCCUPANT TO OBTAIN A SEPARATE PERMIT THROUGH SITE LL AN ACCURATE RECORD OF CHANGES AND DEVIAllONS BETWEEN WORK AS SHOWN AND Cr PLUMBING FIXTURES S/I D THE FIRE PREVEN110N BUREAU. INSTALLED. PLUMBING S/I D 2 ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY 10 FIRE DEPARTMENT ACCESS ROADWAY TO COMPLY WITH FPB POLICY A-85-3, AND 10.207 3 UPON COMPLETION OF WORK, FURNISH ARCHITECT WITH A COMPLETE SET OF MARKED—UP D PLUMBING FITTINGS S/I OF THE CONTRACTOR. NOTED DIMENSIONS TAKE PRECEDENT OVER SCALE. ARCHITECT TO BE U.F.C. REPRODUCIBLES WITH RECORD DOCUMENTS CLEARLY PRINTED IN LOWER RIGHT HAND CORNER Q NOTIFIED IMMEDIATELY OF ANY DISCREPANCY BEFORE PRECEDING WITH ANY WORK. OF EACH SHEET. TRANSFER CHANGES AND DEVIATIONS FROM PROGRESS SET TO FINAL SET. rn FIRE ALARM S/I D D 11 DRAFT STOPS SHALL BE INSTALLED IN FLOOR — CEILING ASSEMBLIES SO THAT THE AREA O 3 ALL DIMENSION SHALL HAVE PREFERENCE OVER SCALE, DO NOT SCALE DRAWINGS. LARGE OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET AND SO THAT THE 4 SIGN EACH FINAL RECORD DRAWING. NOTE THEREON THAT RECORD DOCUMENTS ARE Uj RETAIL MILLWORK D D S/ BLOCKING AS NOTED ON PLANS SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. HORIZONTAL DISTANCE BETWEEN STOPS DOES NOT EXCEED 60 FEET. WERE APPROVED BACK OF HOUSE MILLWORK S/I D D COMPLETE AND ACCURATE. _ 4 NO DEVIATION FROM THE STRUCTURAL DESIGN WITHOUT WRITTEN APPROVAL OF THE AUTOMATIC SPRINKLERS ARE INSTALLED WITHIN THE CONCEALED SPACE, THE AREA BETWEEN GENERAL FINISHES S/I D D AFTER INSTALLS STRUCTURAL AUTHORITY TO DEVIATE FROM THE PLANS OR SPECIFICATIONS. DRAFT STOPS MAY BE 3,000 SQUARE FEET AND THE HORIZONTAL DIMENSION MAY BE 100 FEET. CLEANING: M STORAGE ROOMS ELVING S/I D 5 ALL DIMENSIONS ARE TO THE FACE OF FINISH UNLESS NOTED OTHERWISE. DO NOT SCALE 12 DRAFT STOPS SHALL BE INSTALLED IN ROOF—CEILING ASSEMBLIES SO THAT THE AREA OF 1 THROUGHOUT THE CONSTRUCTION PERIOD, MAINTAIN THE CONSTRUCTION AREA IN A LNN THE CONCEALED SPACE DOES NOT EXCEED 3,000 SQUARE FEET AND THE GREATEST STANDARD OF CLEANLINESS AS DESCRIBED IN THIS SECTION. DRAWINGS. SHELF BRACKETS D S/ HORIZONTAL DIMENSION DOES NOT EXCEED 60 FEET. WHERE APPROVED AUTOMATIC SPRINKLERS GLASS SHELVES D S/ 6 CONTRACTOR SHALL PROVIDE PEDESTRIAN FENCE AND CANOPY AS REQUIRED. A PERMIT ARE INSTALLED THE AREA BETWEEN DRAFT STOPS MAY BE 9,000 SQUARE FEET AND THE 2 CONDUCT DAILY INSPECTION. GREATEST HORIZONTAL DIMENSION MAY BE 100 FEET. rw FLOOR PROTECTION S/I MASONITE AS REWIRED FROM THE DEPARTMENT OF PUBLIC WORKS IS REQUIRED FOR A PROTECTION FENCE OR CANOPY 3 USE ONLY THE CLEANING MATERIAL AND EQUIPMENT WHICH ARE COMPATIBLE WITH THE -1 ON OR OVER STREET OR PUBLIC SPACES. 13 DRAFTSTOPPING MATERIALS SHALL BE NOT LESS THAN 1/2 INCH GYPSUM BOARD, 3/8 SURFACE BEING CLEANED, AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL. APPLIANCES I S D G.C. ALL CONNECTIONS INCH PLYWOOD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. PROVIDE A M CASH WRAP COUNTER I D D S 7 TEMPORARY SANITARY FACILITIES FOR WORKMEN SHALL BE PROVIDED COMPLETE SEAL THE FULL HEIGHT OF THE SPACE. ED DURING 4 DO NOT ALLOW ACCUMULATION OF SCRAP, DEBRIS, WATER, MATERIAL AND OTHER ITEMS CONSTRUCTION. NOT REQUIRED FOR CONSTRUCTION OF THIS WORK. SOUND SYSTEM G.C. TO COORDINATE CONDUIT RUNS 14 PROVIDE A KNOX BOX FOR BUILDING KEY. VERIFY LOCATION WITH FIRE MARSHALL. O O — JUNCTION BOXES S/I D S/I CHOPPING IF REQUIRED 8 PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR 5 AT LEAST ONCE EVERY WEEK, AND MORE OFTEN IF NECESSARY, COMPLETELY REMOVE MECHANICAL, ELECTRIC AND PLUMBING EQUIPMENT. ALL LOCATIONS SHALL BE REVIEWED BY THE 15 ALL PENETRATIONS OF FIRE RATED WALLS SUCH AS FOR HVAC DUCTS, ELECTRICAL, ALL SCRAP, DEBRIS AND WASTE MATERIAL FROM THE CONSTRUCTION AREA. Uj — LOW VOLTAGE WIRE D/S/I G.C. TO PROVIDE WIRE PULLS ARCHITECT. PLUMBING , LTC. SHALL BE TREATED WITH A FIRE STOP SEALANT MEETING THE PROVISIONS OF SECTION 4308 OF THE U.B.C. HAVING F OR T RATINGS AS DETERMINED BY TEST CONDUCTED IN 6 DAILY, AND MORE OFTEN IF NECESSARY, INSPECT THE CONSTRUCTION AREA AND PICK UP �� O L I GBRACKEI S/I D S/I 'SCOPEVATHVEN9 COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL, ELECTRICAL, FIRE ACCORDANCE WITH U.B.C. STANDARD NO. 43-6 STANDARD METHOD E 814-83 OF THE ASTM. ALL SCRAP, DEBRIS AND WASTE MATERIAL. REMOVE SUCH ITEMS TO THE PLACE DESIGNATED - Md POWER S/I D SPRINKLER DESIGNS. WERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND INSTALLATION, ALL PRODUCTS USED SHALL HAVE ICBO NUMBER APPROVAL FOR THEIR STORAGE. Z W REVIEW WITH THE ARCHITECT BEFORE PROCEEDING WITH WORK. — EQUIPMENT SPEAKERS D D S/I 16. FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH SECTION 708.2.1 U.F.C. IN THE 7 PRIOR TO THE COMPLETION OF THE WORK, REMOVE FROM THE CONSTRUCTION AREA, ALL N C O G.C. TO COORDINATE CONDUIT RUNS 10 THE CONTRACTOR SHAL_ PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, FOLLOWING LOCATIONS: TOOLS, SURPLUS MATERIAL, EQUIPMENT, SCRAP, DEBRIS AND WASTE. CONDUCT FINAL to PONT OF SALE HANGERS, OR OTHER SUPPORT FOR ALL FIXTURES, EQUIPMENT AND CABINETRY. PROGRESS CLEANING AS DESCRIBED IN PARAGRAPHS 4 AND 5 ABOVE. Ln — JUNCTION BOXES S/I D DA. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, DOORS AND WINDOWS NOTES: 1AQ COILING AND FLOOR LEVELS. — POWER S/I p 11 CONTRACTOR SHALL PROVIDE A FIRE PROTECTION SYSTEM DURING CONSTRUCTION. AT THE C — LOW VOLTAGE WIRING D/S/I M SUPPLY AND MiALL L;UNDU1r_ 12 CONTRACTOR SHALL COORDINATE ALL SLAB AND WALL OPENINGS REQUIRED BY B. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, 1 ALL DOORS SHALL COMPLY WITH THE MINIMUM STANDARDS SET FORTH IN THE PROJECT Ir ) RUNS AND WIRE PULLS MECHANICAL AND ELECTRICAL DRAWINGS. AT 10—FOOT INTERVALS ALONG THE LENGTH OF THE WALL. SPECIFICATIONS. /� CL O W C. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES !H- — EQUIPMENT D D S/I SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVERED CEILINGS. 2 UNLESS NOTED OTHERWISE, DOORS AND OPENINGS NOT LOCATED BY DIMENSIONS SHALL (y — COMPUTER D/S/I 13 WHERE RECESSED OR NON—MODULAR FIXTURES, DIFFUSERS, SPEAKERS OR OTHER D. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE OPE EXPOSED DEVICES ARE USED, THEY ARE TO BE CENTERED IN THE CEILING TILE PATTERN UNLESS RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF STAIRS IF THE WALL BE CENTERED ON WALL OR SHALL BE LOCATED 5" FROM FINISH WALL TO EDGE OR BACK OF I D D S F7 TO UUUMUINAIL NOTED OTHERWISE. UNDER THE STAIRS IS UNFINISHED. DOOR. — TELEPHONES SCOPE — JUNCTION BOXES S/I D 14 ALL PIPE, DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS SHALL BE INSTALLED 3 INSTALL DOORS AND FRAMES PLUMB, STRAIGHT, IN TRUE ALIGNMENT AND RIGIDLY TELEVISIONS IN A MANNER THAT WILL PRESERVE FIRE RESISTIVE AND STRUCTURAL INTEGRITY OF THE SECURED TO WALLS. ERECT IN PROPER SEQUENCE WITH WORK OF OTHER TRADES. l BUILDING. /V�■ — POWER S/ D D ENERGY CONSTRUCTION STANDARDS: 4 SPECIAL LOCKING DEVICES IF SPECIFIED SHALL BE OF A CITY APPROVED TYPE. — BRACKETS S/ D D 15 ALL MECHANICAL DUCTS PENETRATING FIRE RATED PARTITIONS , CEILING AND SHAFT MATH AV VEN ENCLOSURES SHALL HAVE FIRE RATED DAMPERS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO 1 ALL EXTERIOR DOORS SHALL LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN IN A 5 ALL WINDOWS SHALL COMPLY WITH THE MINIMUM STANDARDS SET FORTH IN THE PROJECT — LOW VOLTAGE WIRING D/S/I FOR VENDORAND INSTA117CONDI COORDINATE WITH THE ARCHITECTURAL DRAWINGS PRIOR TO SUBMISSION OF THE SHOP CLOSED POSITION. SEAL OR ASTRAGAL SHALL BE PROVIDED AT HEAD, SILL, AND JAMBS. SPECIFICATIONS. DRAWINGS. DOORS MOUNTED ON THE INSIDE OR THE OUTSIDE OF EXTERIOR WALLS SHALL HAVE A MINIMUM — EQUIPMENT D/S/I 1" LAP AT JAMBS. MEETING PORTIONS OF SECTIONAL, BI—PARTING, OR DOUBLE DOORS SHALL 6 INSTALLATION OF GLASS SHALL CONFORM TO FEDERAL SPECIFICATION 16—CFR-1202 AND — TERMINATION & TAG S/I D 16 PROVIDE ACOUSTICAL BATT INSULATION AT ALL DUCTS, SHAFTS, TOILET ROOM WALLS AND BE PROVIDED WITH A WEATHER TIGHT ASTRAGAL OR SEAL. THE IBC AND ALL LOCAL CODES AND ORDINANCES. SAFETY GLAZING IN HAZARDOUS LOCATIONS S N C E 8 S MECHANICAL ROOM WALLS ADJACENT TO OCCUPIED TENANT SPACES. SHALL CONFORM TO IBC SECTION 2406. SECISiITY SYSTEM 2 ALL OPERABLE WINDOWS AND SLIDING DOORS SHALL LIMIT AIR LEAKAGE AND BE — WIRING D/S/I 17 IN SOUND RATED ROOMS, ALL WALL AND FLOOR PENETRATIONS FOR PIPE, DUCTS AND CERTIFIED AND LABELED TO COMPLY WITH THE STANDARDS: METAL WINDOWS AND DOORS ANSI 7 ALL DOORS AND OPERABLE WINDOWS TO BE COMPLETELY WEATHERSTRIPPED. INCLUDING OUTLETS SHALL BE SEALED WITH AN ACOUSTIC SEALANT AND CONCEALED OR RECESSED A 134.2-1972 AND WOOD WINDOWS AND DOORS NWMA 1 S-3. FIXED WINDOWS SHALL BE ROLL—UP TRUCK DOORS. — EQUIPMENT D/S/I FIXTURES SHALL BE COVERED OR BACKED WITH SOUND ATTENUATION BLANKETS. SEALED TO LIMIT AIR INFILTRATION 8 ALL MANUFACTURED WINDOW AND DOOR UNITS SHALL BE LABELED AS MEETING ANSI slam� 18 THE ARCHITECT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE GENERAL 3 CALCULATIONS SHALL BE SIGNED BY A OREGON LICENSED ENGINEER, ARCHITECT OR STANDARDS FOR AIR INFILTRATION. — INTERIOR SIGNAGE D D S/ CONTRACTOR OR SUBCONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE DRAWINGS CONTRACTOR. OPEN EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, BETWEEN WALLS OR SPECIFICATIONS UNLESS HE HAS IN WRITING, CALLED THE ARCHITECT'S ATTENTION TO SUCH AND FOUNDATIONS, BETWEEN WALLS AND ROOF, BETWEEN WALL PANELS, AT PENETRATIONS OF 9 INSULATION MATERIAL SHALL MEET THE MINIMUM INFILTRATION REQUIREMENTS PER — EXTERIOR D D S/ DEVIATIONS AT TIME OF SUBMISSIONS, NOR SHALL IT RELIEVE HIM FROM RESPONSIBILITY FOR UTILITIES THRU THE ENVELOPE, SHALL BE SEALED, CAULKED, OR WEATHER STRIPPED TO LIMIT SECTION 2.5312 B.E.E.S. — MOST CURRENT EDITION w — EXTERIOR LIGHTING I D D S ERRORS OF ANY SORT IN THE SHOP DRAWINGS. AIR LEAKAGE SHALL CONFORM TO U.B.C. SECTION 5406. 10 DOORS AND WINDOWS SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF i ARTWORK19 PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE APPLICANT SHALL HAVE EVIDENCE 4 PROVIDE COMPLETE CALCULATIONS AS REQUIRED FOR ENERGY ENVELOPE SECTION 2.5317 B.E.E.S. — MOST CURRENT EDITION 0 z a D/S OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE ON FILE WITH THE BUILDING 11 ALL EXTERIOR DOORS SHALL LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN INA i FREESTANDING GRAPHICS DEPARTMENT IN COMPLIANCE WITH THE GOVERNING LABOR CODE. 5 SPECIFY THE THICKNESS, THERMAL RESISTANCE (R VALUE) AND APPROPRIATE FEDERAL F WALL GRAPHICS D/S SPECIFICATIONS OF ALL INSULATING MATERIALS. CLOSED POSITION. SEAL OR ASTRAGAL SHALL BE PROVIDED AT HEAD, SILL AND JAMBS. � Z DOORS MOUNTED ON THE INSIDE OR THE OUTSIDE OF EXTERIOR WALLS SHALL HAVE A v0— 20 THE CONTRACTOR SHALL CONFORM TO CODES, ORDINANCES, ETC., WHICH HAVE MINIMUM 1" LAP AT JAMBS. MEETING PORTIONS OF SECTIONAL, BI—PARTING, OR DOUBLE C o W FLOJURISDICTION OVER THIS WORK. THE CONTRACTOR SHALL RETAIN RESPONSIBILITY FOR PRODUCT HANDLING: DOORS SHALL BE PROVIDED WITH A WEATHER TIGHT ASTRAGAL OR SEAL. U loc — WOOD FLOORING S/I D D COMPLIANCE WITH THE ORDINANCES, INCLUDING THE FOLLOWING: 1 EXCEPT AS OTHERWISE APPROVED BY THE ARCHITECT, DETERMINE AND COMPLY WITH SUBSTITUTIONS: — WOOD BASE S/I D D 2013 OREGON BUILDING CODE ' �+ Lo MANUFACTURER'S RECOMMENDATIONS ON PRODUCT HANDLING, STORAGE AND PROTECTION. a AN 1 SUBSTITUTION WILL BE CONSIDERED ONLY MEN LISTED AT TIME OF BIDDING, ON THE C N N — VINYL BASE S/I D D 21 EXPANSION ANCHORS BY HILT] SHALL BE AT 4'-0" O.C. MAX. TYPICAL & HAVE L.A. R.R. FORM PROVIDED THEREFORE IN CONTRACTORS SUBMITTAL OF REQUIRED DATA WITHIN 35 V W m m � — VCT S/I D D 2 DELIVER PRODUCTS TO THE JOB SITE IN THEIR MANUFACTURER'S ORIGINAL CONTAINER, rL o a #23272 & I.C.B.O. #1372 CALENDAR DAYS AFTER AWARD OF THE CONTRACT. WITH LABELS INTACT AND LEGIBLE. MAINTAIN PACKED MATERIALS WITH SEALS UNBROKEN AND J E to 0 0 — BRICK WALL TILE S/1 D D 22 SHOT PINS BY HILT] SHALL BE AT 4' — 0" O.C. MAX. TYPICAL & SHALL HAVE L.A. R.R. LABELS INTACT UNTIL TIME OF USE. SECURITY NOTES: J O � Q . — MOSAIC TILE I D/S D #2582 & ICC ES 2269 3 PROMPTLY REMOVE DAMAGED MATERIAL AND UNSUITABLE ITEMS FROM THE JOB SITE, V d 1 WOOD FLUSH DOORS SHALL BE A MINIMUM 1 3 8" THICK WITH SOLID CORE la+ 23 PROVIDE 2 COATS CLEAR INDUSTRIAL GLOSS ENAMEL OVER PRIMER ON ALL EXPOSED AND PROMPTLY REPLACE WITH MATERIAL MEETING THE SPECIFIED REQUIREMENTS, AT NO / 2C >+ m m a — MARBLE TLE I D/S D CONSTRUCTION. ADDITIONAL COST TO THE OWNER. SAFE S LOCKERS I S G.C. TO COORDINATE STRUCTURAL STEEL MEMBERS, STEEL SUPPORT, STRUCTURAL RAILINGS, PIPE CHANNELS AND _ �3 BRACING, UNLESS NOTED OTHERWISE 2 HOLLOW CORE DOORS OR DOORS LESS THAN A 1 3/8" IN THICKNESS SHALL O COVERED $ o 4 PROTECT FINISHED SURFACES, INCLUDING JAMBS AND SOFFITS OF OPENINGS USED AS C NG SYSTEMS ON THE INSIDE FACE WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT 6" ON CENTER 24 ALL CONCRETE SURFACES TO BE PAINTED SHALL RECEIVE A MINIMUM OF THREE COATS OR PASSAGEWAYS, AND FLOORS THROUGH WIHICH EQUIPMENT IS HANDLED. AROUND PERIMETER. r — 2x4 CEILING TILES S/I D TWO COATS ON PRIMER. TYPICAL UNLESS NOTED OTHERWISE. J o 5 IN THE EVENT OF DAMAGE, PROMPTLY MAKE REPLACEMENTS AND REPAIRS TO THE Z W — GYPSUM BOARD S/I D 3 WOOD PANEL TYPE DOORS SHALL HAVE PANELS FABRICATED OF NOT LESS 9/16" INCH 'sem n o APPROVAL OF THE ARCHITECT AND AT NO ADDITIONAL COST. CO — LIGHTING I D S 25 THE CENTER OF RECEPTACLE OUTLETS SHALL NOT BE LESS THAN 12—INCHES ABOVE THE THICKNESS, PROVIDED THE SHAPED PORTIONS OF THE PANEL ARE NOT LESS THAN 1/4" THICK. W w v FLOOR OR WORKING AREA. CONSTRUCT ON FACILITIES: INDIVIDUAL PANEL SHALL NOT EXCEED 300 SQ. INCHES IN AREA. STILES AND RAILS SHALL BE 1 WHEREVER GC HAS RESPONSIBILITIES TO INSTALL MATERIAL OR EQUIPMENT FURNISHED BY OWNER OR VENDORS, RESPONSIBILITY INCLUDES 26 THE CENTER OF THE OPERATING HANDLE GRIP OF SWITCHES INTENDED TO BE USED BY OF SOLID LUMBER WITH OVERALL DIMENSIONS OF NOT LESS THAN 1 3/8" AND 3" IN WIDTH. E F ) THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, 1 PROVIDE AND MAINTAIN EQUIPMENT SUCH AS SCAFFOLDS, STAGING, LADDERS, STAIRS, MULLIONS SHALL BE CONSIDERED A PART OF ADJACENT PANELS UNLESS SIZED AS REQUIRED J RECEIVING, UNLOADING, INSPECTING, INVENTORYING, STORING AND HANDLING THE MATERIAL. AV WILL UNLOAD THEIR OWN EQUIPMENT. RAMPS, RUNWAYS, PLATFORMS, RAILINGS, HOISTS, CRANES AND OTHER EQUIPMENT REQUIRED HEREIN FOR STILES AND RAILS EXCEPT MULLIONS NOT OVER 18" LONG MAY HAVE AN OVERALL APPLIANCES, OR COOLING, HEATING AND VENl1LAl10N EQUIPMENT, SHALL NOT BE LESS THAN TO ASSURE SAFETY OF PERSONNEL TO FACILITATE EXECUTION OF WORK. WIDTH OF NOT LESS THAN 2". CARVED AREAS SHALL HAVE A THICKNESS OF NOT LESS THAN �p G PLATFORM.. 3/8" 2) THIS MATRIX IS INTENDED TO HELP DEFINE THE VARIOUS RESPONSIBILITIES OF THE PARTIES INVOLVED. IT IS NOT INTENDED TO 3—FEET NOR MORE THAN 4—FEET ABOVE THE FLOOR OR WORKC BE AN EXCLUSIVE OR COMPLETE LIST, THE GC SHALL ABIDE BY THE CONTRACT DOCUMENTS AND PROVIDE SUCH SERVICES AND 2 EXECUTE WORK WITH A CONSTANT EFFORT TO ELIMINATE UNNECESSARY NOISE, DUST AND O_ MATERIAL AS REQUIRED TO PRODUCE A COMPLETE AND FINISHED JOB, WHETHER THOSE ITEMS APPEAR ON THIS MATRIX OR NOT. 27 THE CENTER OF THE FIRE ALARM INITIATION DEVICES (BOXES)(IF PROVIDED) SHALL BE OTHER ANNOYANCES. 4 GLAZED OPENINGS, WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED p LOCATED 48—INCHES ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY RESISTANT MATERIAL, ,p OR SIDEWALK. FIRE SPRINKLER NOTES: OR SHALL BE PROTECTED BY METAL BARS , SCREENS OR GRILLS HAVING A MAXIMUM OPENING W • OWNER / CLIENT —(KIEHL'S SINCE 1851) CONTACT: ADAM PECK OF 2' p STUDIO DIRECTOR — (FITCH ARCHITECTS) CONTACT: KEITH HEINEMANN / NICK RUSH (480) 998-4200 28 IF EMERGENCY WARNING SYSTEMS ARE REQUIRED THEY SHALL ACTIVATE A MEANS OF 1 THE MODIFICATION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SHALL COMPLY WITH THE PROJECT ENGINEER — (CONSOLIDATED MEP ENGINEERING) CONTACT. ELIAS MENDEZ (714) 893-6157 WARNING FOR THE HEARING IMPAIRED. FLASHING VISUAL WARNINGS SHALL HAVE A FREQUENCY LATEST EDITION OF CODES, AS ADOPTED BY LOCAL JURISDICTION. 5 DOOR STOPS OF IN—SWINGING DOORS SHALL BE OF ONE PIECE CONSTRUCTION WITH JAMB `r LIGHTING VENDOR — (CS ILLUMINATION) CONTACT: CHERYL PALMER (845) 228-9479 OF NOT MORE THAN 60 FLASHES PER MINUTE. TI — d OR JOINED RABBET TO THE JAMB. Y � MILLWORK VENDOR — (ORION RETAIL SERVICES) CONTACT: TOM MACKAY (401) 334-5000 2 DESIGN SPRINKLER SYSTEM AS REQUIRED = t_ AUDIO / VISUAL VENDOR — (ECI) BOB CROZER (908) 412-9500 29 FLOOR SURFACES SHALL BE SLIP RESISTANT MEETING THE REQUIREMENTS OF 6 ALL PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED AREA WHEN Q O 2014 OREGON STRUCTURAL SPECIALTY CODE 3 WHEN SERVING MORE THAN 100 SPRINKLER HEADS, AUTOMATIC SPRINKLER SYSTEMS POINT OF SALES VENDOR — (SPS) MARK BUDINGER THE DOOR IS CLOSED SHALL HAVE NON—REMOVABLE HINGE PINS. IN ADDITION THEY SHALL � SHALL BE SUPERVISED BY AN APPROVED CENTRAL PROPRIETARY OR REMOTE STATION SERVICE, SECURITY VENDOR RI (TRIAD SECURITY) CONTACT: GARY FALL (908) (410)2 4 OR SHALL BE PROVIDED WITH A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A HAVE 1/4'HAP DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM PROTECTION A UNLESS THE HINGES 3 SIGN VENDOR — (TRIANGLE SIGN & SERVICE) CONTACT: BOB NETHEN (410) 247-5300 30 IF TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH ARE REQUIRED, G.C. TO OBTAIN CONSTANTLY ATTENDED LOCATION. ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE HINGE PINS ARE REMOVED. d INFORMATION TECHNOLOGY SYSTEMS — (L'OREAL USA) CONTACT: MATTHEW BOUTILLIER (732) 951-4267 NECESSARY ISSUANCE OF A BUILDING OR GRADING PERMIT. Z TO TELEPHONE VENDOR — (L'OREAL USA) CONTACT: LINDA CARBLEY (732) 499-2684 4 CONTROL VALVES AND WATERFLOW ALARMS TO BE MONITORED BY A CENTRAL ALARM 7 THE STRIKE PLATES FOR HINGES AND l HOLDING DEVICE FOR PROTECTED DEAD BOLTS SAFETY CONTROL — (L'OREAL USA) CONTACT. DOUG PASTORE 31 THE CONTRACTOR SHALL CHECK AND VERIFY SIZE AND LOCATION OF DUCT OPENINGS MONITORING SERVICE. IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SHOPPERTRAK VENDOR — (SHOPPERTRAK RCT CORPORATION) JASON STEUBER (312) 529-5359 AND PLUMBING RUNS WITH MECHANICAL CONTRACTOR BEFORE FORMING WALLS, FLOORS, ETC. SCREWS NOT LESS THAN 2 1/2' IN LENGTH. 5 ELECTRICAL SUBCONTRACTORS TO INSTALL WIRING FOR FIRE SPRINKLER ALARM BELL AND 32 DEPUTY INSPECTOR SHALL BE REGISTERED WITH PORTLAND PRIOR TO INSPECTION OFTELEPHONE WARNING AS REQUIRED BY FIRE DEPARTMENT. 8 DEAD BOLTS WITH HARDENED INSERTS SHALL BE INSTALLED UNDER THE FOLLOWING WORK. CONDITIONS: DEADLOCKING LATCH KEY—OPERATED LOCKS ON EXTERIOR; LOCKS OPERABLE 6 � A WITHOUT KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT ON INTERIOR; AND TYPE THROW AND V� �Ct 33 FIRE BLOCK STUD WALLS (AT 10' INTERVALS [HORIZONTAL AND VERTICAL]), ENCLOSED 6 ALL FIRE ALARM SYSTEMS SHALL BE INSTALLED IN COMPLIANCE WITH CODES. EMBEDMENT OF DEAD BOLTS FOR SINGLE SWINGING DOOR, ACTIVE LEAF OR PAIRS OF DOORS, ~S� BLAIRS. �r� AND CONCEALED SPACES, AND AT OPENINGS AROUND VENTS, PIPES, DUCTS, AND SIMILAR 7 LOCATE HEAD CENTERED IN 2'x2' CEILING TILES, IN 2'x4' CEILING TILES, LOCATE OR BOTTOM LEAF OF DUTCH DOOR. �V LEACH tl' PLACES AT CEILING AND FLOOR LEVELS CENTERED IN THE 2' DIMENSION AND NO CLOSER THAN 1' TO EACH END IN THE 4' DIMENSION OR ALIGN WITH LIGHT FIXTURES. 9 STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF FIRE SAFETY NOTES: NOT LESS THAN 5/8". 1/S/l5 8 ALL SPRINKLER SYSTEM TO BE APPROVED BY BUILDING DEPARTMENT AND FIRE SCOTTSDALE,Az 1 FIRE DEPARTMENT FINAL INSPECTION REQUIRED. NOTIFY 24 HOURS IN ADVANCE. PREVENTION DEPARTMENT PRIOR TO INSTALLATION. 0 A HOOK SHAPED OR EXPANDING—LUG DEAD BOLT SHALL HAVE A MINIMUM THROW OF �� 61134 O� 3/4". 2 PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT INCLUDING FIRE SPRINKLER SYSTEM 9�C OF PLANS, SHALL BE SUBMITTED BY INSTALLING CONTRACTOR. SUCH PLANS SHALL BE APPROVED ARCHITECTS REVIEW: 11 CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE BY FIRE PREVENTION BUREAU PRIOR TO INSTALLATION. CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO 1 REVIEW BY THE ARCHITECT DOES NOT RELIEVE THE CONTRACTOR FROM ERRORS WHICH GRIPPING TOOLS. 3 FIRE HYDRANTS SHALL COMPLY WITH FIRE DEPARTMENT REQUIREMENTS FOR ON SITE MAY EXIST IN THE SUBMITTAL DATA. DATE' 12/23/14 SHEET' HYDRANTS. 12 UPPER LEAF OF DUTCH DOORS SHALL HAVE A SURFACE MOUNTED PIN BOLT WITH /� 2 REVISIONS: MAKE REVISIONS INDICATED BY THE ARCHITECT. IF THE CONTRACTOR MINIMUM 1/2" EMBEDMENT INTO COUNTER AT LOWER LEAF LOCATED ON THE INSIDE SURFACE SME: A5 NOTW ` �� 4 FIRE PREVENTION WATER SERVICE SHALL BE IN SERVICE PRIOR TO DELIVERY TO SITE OF CONSIDERS ANY REVISION TO BE CHANGED, HE SHALL NOTIFY THE ARCHITECT. OF THE DOOR. DRAWN COMBUSTIBLE BUILDING MATERIALS. �' PROJECT MEETINGS: 13 SCREEN BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDE HUMAN CLIMBING N.R. J "90 SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, BALCONY OR SIMILAR SURFACE PROJECT No.: 300 WHICH IS WITHIN 8' OF A UTILITY POLE OR SIMILAR STRUCTURE 1 PROJECT MEETINGS: SCHEDULE AND ADMINISTER THROUGHOUT PROGRESS OF WORK. 320103498 . LLSS GENERAL NOTES SHOPPERTRAK INSTRUCTIONS FINISH SCHEDULE COPYRIGHT NOTICE: These drawings and specifications am copyrighted and subject to copyright prole<tion as on 'architectural work" under sec. 102 of the copyright act. 17 u.S.C. N amended december 1990. The protection includes, PAINT compwithout tion limitation, the overall Corm, arrangement and OFF-SITE CONSTRUCTION NOTES: (IF APPLICABLE) 6 SCALE AND MEASUREMENTS: MAKE SHOP DRAWINGS ACCURATELY TO SCALE SUFFICIENTLY LARGE TO CABLING INSTRUCTIONS composition of ation, and elements of the design. SHOW ALL PERTINENT ASPECTS OF THE ITEM AND ITS METHOD OF CONNECTION TO THE WORK. PRE WIRING A STORE FOR SHOPPERTRAK ORBIT 5 drawings and specifications maynresult in ocessation of 1 ALL LABOR, EQUIPMENT AND MATERIAL REQUIRED FOR OFF SITE IMPROVEMENTS ARE THE SINGLE HOST OR TS100 INSTALLATIONS construction, buuding seizure, and/or monetary liability. RESPONSIBILITY OF THE DEVELOPER. 7 PROVIDE SAMPLE OR SAMPLES IDENTICAL TO THE PRECISE ARTICLE PROPOSED TO BE PROVIDED. IDENTIFY AS DESCRIBED UNDER "IDENTIFICATION OF SUBMITTALS" BELOW. BELOW IS A DESCRIPTION OF THE CABLING REQUIREMENTS FOR SHOPPERTRAK'S ORBIT 5 PRODUC-. BENJAMIN MOORE, COLOR: CHINA WHITE. SEMI-GLOSS AT BRICK. 2 THE OFF-SITE WORK SHALL BE DONE IN ACCORDANCE WITH THE "STANDARD SPECIFICATIONS / (SHOPPERTRAK WALL BE INSTALLING THE ACTUAL ORBIT UNITS AT A LATER DATE) P-1 PROVIDE SAMPL=S FOR TENANTS APPROVAL DRAWINGS FOR PUBLIC WORKS CONSTRUCTION", CURRENT EDITION AS AMENDED BY THE CITY OF PORTLAND, 8 NUMBER OF SAMPLES REQUIRED: ONE SAMPLE FOR OWNER'S RETAINAGE; AND NUMBER OF SAMPLES AND CITY OF PORTLAND STANDARDS. REQUIRED BY CONTRACTOR. SINGLE ORBIT 5 INSTALLATIONS: IM B M 172, REVERE PEWIERA. 3 NO WORK SHALL BE DONE WITHIN THE PUBLIC RIGHT OF WAY WITHOUT THE PRIOR APPROVAL OF THE 9 TYPE OF PRINTS REQUIRED: SUBMIT SHOP DRAWINGS IN THE FORM OF ONE SEPIA TRANSPARENCY OR FOR SINGLE ORBIT 5 INSTALLATIONS, A CATEGORY 5 CABLE MUST BE RUN FROM THE SHOPPERTRAK HOST TO P�2 P A TENANTS APPROVAL. ENVIRONMENTAL AND PUBLIC WORKS MANAGEMENT DEPARTMENT - ADMINISTRATIVE SERVICES. XEROX TRANSPARENCY. THE FRONT DOOR (MAIN CUSTOMER ENTRANCE). 4 TREES WITH IN THE PUBLIC RIGHT OF WAY CANNOT BE REMOVED BY THE PROPERTY OWNER FOR ANY 10 REVIEW COMMENTS OF THE ARCHITECT WILL BE SHOWN ON THE SEPIA TRANSPARENCY WHEN IT IS CHECK WITH SHOPPERTRAK OR THE CLIENT STORE SYSTEMS GROUP TO DETERMINE THE SHOPPERTRAK HOST P6-3 BENJAMIN MOORE, COLOR: DECORATOR'S WHITE. FLAT FINISH. REASON WITHOUT THE WRITTEN APPROVAL OF THE PARKS AND SPORTS DIVISION OR THE DIRECTOR OF RETURNED TO THE CONTRACTOR. THE CONTRACTOR MAY MAKE AND DISTRIBUTE SUCH COPIES AS AREPROVIDE SAMPLES FOR TENANT'S APPROVAL ENVIRONMENTAL AND PUBLIC WORKS MANAGEMENT. REQUIRED FOR HIS PURPOSES. LOCATION. IN MOST CASES, THE HOST WILL BE EITHER A MODEM OR TCP/IP TO R5485 SERIAL CONVERTER, INSTALLED NEAR THE TELECOMM BOARD, STORE CONTROLLER, OR NETWORK SWITCH. B M CHINA WHITE. FLAT FINISH. 5 OWNER IS RESPONSIBLE FOR REPAIR OF ALL DAMAGE TO OFFSITE IMPROVEMENTS CAUSED BY1HE ORBIT 5 UNIT WILL BE INSTALLED CENTERED ABOVE THE DOORWAY. THE DISTANCE IN FROM THE P-4 PTATENANT'S APPROVAL L CONSTRUCTION. CALL PUBLIC WORKS INSPECTOR FOR INSPECTION OF OFFSITE IMPROVEMENTS AT SUBSTANTIAL SUBMITTALS: DOORWAY WILL VARY DEPENDING UPON WHICH DIRECTION THE DOOR SWINGS. COMPLETION OF ONSITE WORK. 1 COORDINAl10N OF SUBMITTALS P ' '� ITE. EXITING NOTES: - IN A LOCATION WHERE THERE IS NO DOORS/MALL OPENING ENTRANCE - THE ORBIT 5 UNIT WILL P-5 P 6A - NANT`S APPROVAL. PRIOR TO EACH SUBMITTAL, CAREFULLY REVIEW AND COORDINATE ALL ASPECTS OF EACH ITEM BEING BE MOUNTED 12" TO 24" IN FROM THE DOOR THRESHOLD. 1 FINISH HARDWARE FOR ALL LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE SUBMITTED. B ✓ IM 12-10 - COLOR: FLAT BLACK, MATTE FINISH Cr IN A PATH OF TRAVEL SHALL COMPLY WITH STATE BUILDING CODE. - IN A LOCATION WHERE THE DOORS SWING OUT - THE ORBIT 5 UNIT WILL BE MOUNTED 24" TO 36" P-8 P A TENANTS APPROVAL. VERIFY THAT EACH ITEM AND THE SUBMITTAL FOR IT CONFORMS IN ALL ASPECTS WITH THE SPECIFIED INCHES IN FROM THE DOOR JAMB. kA 2 EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING HAZARDOUS AREAS OR AN REQUIREMENTS. OCCUPANT LOAD OF MORE THAN 50 PERSONS. - IN A LOCATION WHERE THE DOORS SWING IN - THE ORBIT 5 UNIT WILL BE MOUNTED 24" TO 36" STAMP SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES WITH CONTRACTOR'S STAMP CERTIFYING IT HAS INCHES IN FROM THE FURTHER IN-SWING OF THE DOORS. O Q 3 DOUBLE ACTING DOORS ARE NOT PERMITTED WHEN SERVING AN OCCUPANT LOAD OF MORE THAN 100. BEEN COORDINATED AND CHECKED BY THE CONTRACTOR FOR COMPLETENESS AND COMPLIANCE WITH CONTRACT DOCUMENTS. SUBMITTALS NOT STAMPED, AND SUBMITTALS WHICH, IN ARCHITECT'S OPINION ARE HISTORICAL NOTE: DO NOT MOUNT AT 36" TO 48" INCHES IN FROM THE DOOR, AS WAS THE POLICY WITH P�T � 4 EXIT DOORWAYS SHALL NOT BE LESS THAN 36" WIDE AND 6'-8" IN HEIGHT. ALL REQUIRED EXIT INCOMPLETE, CONTAIN NUMEROUS ERRORS OR HAVE NOT BEEN CHECKED OR HAVE ONLY BEEN CHECKED ORBIT 3A. DOORS SHALL BE NOT LESS THAN WE WIDE, 6'-8" HIGH, SHALL HAVE A CLEAR EXIT WAY WIDTH OF NOT SUPERFICIALLY WILL BE RETURNED FOR RESUBMITTAL. CLEARLY NOTE PROPOSED DEVIATIONS FROM CONTRACT PAINT SHEENS ON SURFACES TO BE AS FOLLOWS: �\ M '' DOCUMENTS ON SUBMITTALS. CONTRACTOR RESPONSIBLE FOR QUANTITIES AND DIMENSIONS SHOWN ON PLEASE LEAVE 15-20OF CABLE COILED UP AT EACH END OF THE RUN. AT THE FRONT DOOR LEAVE THE • SALES AREA WALLS AND CEILING - EGGSHELL LESS THAN 32" AND SHALL BE CAPABLE OF OPENING 90 DEGREES. THE MAXIMUM DOOR LEAF WIDTH IS 4 L FEET WHEN SERVING AN OCCUPANT LOAD OF 10 OR MORE.. SUBMITTALS. CABLE COIL IN A LOCATION THAT CAN BE REACHED USING AN 8' LADDER. • ALL DOORS AND FRAMES - SEMI GLOSS 5 A SINGLE LEAF ON AN EXIT DOOR SHALL NOT EXCEED 4' IN WIDTH. 2 IDENTIFICATION OF SUBMITTALS IF THE STORE WILL HAVE A HARD (PLASTER OR SHEETROCK) CEILING, PLEASE INSTALL A JUNCTION BOX • STOCK RM., HALLWAY, OFFICES AND OTHER NON SALES AREA WA = __ ■ UJUJ 6 ALL WALLS AND CEILINGS OF EXIT CORRIDORS AND PUBLIC LOBBY AREAS SHALL BE OF ONE-HOUR FIRE PROPERLY IDENTIFY EACH SUBMITTAL WITH A NAME OF PROJECT, CONTRACTOR, SUBCONTRACTOR, AND 3"-4" AWAY FROM THE RECOMMENDED ORBIT LOCATION SPECIFIED ABOVE. • INSIDE TOILET ROOM WALLS, CEILING DOOR AND FRAME - G'-OSS RESISTIVE CONSTRUCTION. REFER TO DRAWINGS FOR MATERIALS AND CONSTRUCTION. DATE. ACCOMPANY EACH SUBMITTAL BY AN ACCEPTABLE TRANSMITTAL FORM REFERRING TO PROJECT NAME MULTIPLE ORBIT 5 INSTALLATIONS: -! La AND SPECIFICATION SECTION NUMBER WHEN APPLICABLE FOR IDENTIFICATION OF EACH ITEM LISTED ON Q 7 ALL INTERIOR OPENINGS IN CORRIDOR WALLS AND CEILINGS. DOORS AND FRAMES SHALL BE LABELED 20 TRANSMITTAL. MULTIPLE ORBIT 5 INSTALLATIONS SHOULD BE CABLED IN EITHER A DAISY CHAIN OR STAR TOPOLOGY O MINUTES FIRE RATED ASSEMBLIES WITH SELF CLOSURES OR AUTOMATIC CLOSURES WITH SMOKE DETECTORS. UJ CONSECUTIVELY NUMBER ALL SUBMITTALS: WHEN MATERIAL IS RESUBMITTED FOR ANY REASON, DEPENDING UPON THE TOTAL NUMBER OF ORBITS AND RUN LENGTH. 8 EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OF AN EXIT SIGN IS TRANSMIT UNDER A NEW LETTER OF TRANSMITTAL AND WITH NEW TRANSMITTAL NUMBER. ON RESUBMIT, CITE THE MAXIMUM ALLOWABLE RUN LENGTH FOR A CHAIN OF ORBITS IS 1500' DIVIDED BY THE NUMBER OF PANT NOTES: O ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT THE ORIGINAL SUBMITTAL NUMBER FOR REFERENCE. ORBITS ON THE RUN. CANDLES (54 (Ix) FROM EITHER OF TWO ELECTRIC LAMPS. INTERNALLY ILLUMINATED SIGNS SHALL PROVIDE 1. ALL GYP. BD. SURFACES THROUGHOUT SHALL HAVE A SMOOTH (NO TEXTURE) SANDEC A ■ EQUIVALENT LUM NANCE AND BE LISTED FOR THE PURPOSE. ACCOMPANY EACH SUBMITTAL WITH A LETTER OF TRANSMITTAL SHOWING ALL INFORMATION REQUIRED IF THE TOTAL RUN LENGTH IS LESS THAN 1500' DIVIDED BY THE NUMBER OF ORBITS (1500'/n), WIRE THE FOR IDENTIFICATION AND CHECKING. ORBITS IN A DAISY CHAIN TOPOLOGY. SURFACE AND SHALL BE PREPARED FOR PAINT FINISH AS SPECIFIED ON THE PLANS. � O 9 PROVIDE TWO SEPARATE CIRCUITS FOR EXIT SIGNS CONFORMING TO LOCAL STATE BUILDING CODE. 2. ALL PAINT USED SHALL BE COMMERCIAL WATER BASED INTERIOR ENAMEL ON AT LEAST THE FIRST PAGE OF EACH SUBMITTAL, AND ELSEWHERE AS REQUIRED FOR POSITIVE IF THE TOTAL RUN LENGTH IS GREATER THAN 1500' DIVIDED BY THE NUMBER OF ORBITS (1500'/n). WIRE ■ IIA IDENTIFICATION, SHOW THE SUBMITTAL NUMBER IN WHICH THE ITEM WAS INCLUDED. ( / ) 3. ALL NEW GYP. BD. SURFACES SHALL RECEIVE 3 (THREE) COATS OF PAINT. 10 EMERGENCY LIGHTING SHALL PROVIDE EXIT PATHWAYS WITH AT LEAST ONE FOOT CANDLE AT FLOOR THE ORBITS IN A STAR TOPOLOGY. ) N r LEVEL. TO, BE ON SEPARATE SOURCES OF POWER AND SHALL COMPLY WITH THE ELECTRICAL CODE MAINTAIN AN ACCURATE SUBMITTAL LOG FOR THE DURATION OF THE WORK SHOWING CURRENT STATUS 4. ALL GYP. BD SURFACES TO RECEIVE WALLCOVERING OR OTHER APPLIED FINISHES40 UJ 9 X OF ALL SUBMITTAL AT ALL TIMES. MAKE THE SUBMI-TAL LOG AVAILABLE TO THE ARCHITECT FOR HIS REVIEW DAISY-CHAIN TOPOLOGY: SUCH AS WALLCOVERING, SLAIYYALL OR WALL PANELS SHALL RECEIVE A SMOOTH ■ A /w 11 THE PATH OF EXIT TRAVEL TO AND WITHIN EXISTS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS UPON REQUEST. r / • CONFORMING TO THE REQUIREMENTS OF SECTION 1003.2.8. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY A CATEGORY 5 CABLE MUST BE RUN FROM THE SHOPPERTRAK HOST TO THE FIRST ORBIT 5 UNIT. IN MOST SANDED FINISH AND PRIMER TO MATCH ADJACENT FINISHES. PRIMER TO DRY NO LESS Ln 0 DIRECTION OF APPROACH. EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE THAN 72 HOURS BEFORE FINAL MATERIAL IS APPLIED UNLESS OTHERWISE NOTED. DIRECTION OF EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET 30480 MM FROM THE NEAREST 3 TIMING OF SUBMITTALS CASES, THE "FIRST" ORBIT 5 SHOULD O THE LEFT-MOST ORBIT ABOVE THE LEFT-MOST DOORWAY, G Z ( ) OBSERVED FROM INSIDE THE STORE LOOKING OUT. IF THIS WOULD RESULT IN AN UNNECESSARILY LONG - •� A � O W VISIBLE SIGN. MAKE SUBMITTALS FAR ENOUGH IN ADVANCE OF SCHEDULED DATES FOR INSTALLATION TO PROVIDE CABLE RUN, THE HOMERUN CAN BR RUN TO OPPOSITE END OF THE CHAIN. L / 12 THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM PROVIDED FROM TIME REQUIRED FOR REVIEW, FOR SECURING NECESSARY APPROVALS, FOR POSSIBLE REVISIONS AND a STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR SET, AND THE SYSTEM SHALL BE RESUBMITTALS, AND FOR PLACING ORDERS AND SECURING DELIVERY. CHECK WITH SHOPPERTRAK OR THE CUENT'S STORE SYSTEMS GROUP TO DETERMINE THE SHOPPERTRAK HOS INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODE. FOR HIGH-RISE BUILDINGS, SEE SECTION 403. LOCATION. IN MOST CASES, THE HOST WILL EITHER BE A MODEM OR TCP/IP TO RS485 SERIAL CONVERTER, BRICK VENEER IN SCHEDULING, ALLOW AT LEAST TEN WORKING DAYS FOR REVIEW BY ARCHITECT FOLLOWING HIS INSTALLED NEAR THE TELECOM BOARD, STORE CONTROLLER, OR NETWORK SWITCH. 13 THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE RECEIPT OF THE SUBMITTAL. PREMISES OF ELECTRICAL SUPPLY. IN THE EVENT OF ITS FAILURE, ILLUMINATOR SHALL BE AUTOMATICALLY ANOTHER LINE MUST BE RUN FORM THE FIRST ORBIT TO THE SECOND, THEN ANOTHER LINE FROM THE BR-1ROBINSONBRICK OR GENERAL SHALE AND BRICK, TOWNSQUARE, FACE CUT, 408-683-2580 GROUT: • ' PROVIDED FROM AN EMERGENCY SYSTEM FOR GROUP 1, DIVISION 1.1 AND 1.2 OCCUPANCIES AND FOR ALL SECOND TO THE THIRD, AND SO ON, UNTIL ALL UNITS ARE NETWORKED IN A DAISY-CHAIN TOPOLOGY. GROUT: POLYBEND /j19 PEWTER OTHER OCCUPANCIES WHERE THE MEANS OF EGRESS SYSTEM SERVES AN OCCUPANT LOAD pf 100 OR MORE. PLEASE LEAVE 15-20' OF CABLE COILED UP AT EACH END OF EACH RUN. AT THE FRONT OF THE STORE, LEAVE THE CABLE COIL(S) IN A LOCATION THAT CAN BE REACHED USING AN 8' LADDER. TACK SURFACES 14 EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE ^ OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED. "APPLIES ALSO TO EXIT GATES". THE ORBIT SPACING IN EACH ENTRYWAY: �SBLMA UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. IF ONLY ONE ORBIT IS REQUIRED FOR AN ENTRYWAY, THE ORBIT WILL BE CENTERED FROM LEFT-TO-RIGHT FB-1 87 MPLE FOR TENANT'S APPROVAL. 15 POST A SIGN ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1" LETTERING STATING: "THIS DOOR ACROSS THE ENTRYWAY. S I N C E 1851 MUST REMAIN UNLOCKED DURING BUSINESS HOURS." MAIN EXIT ONLY. IF MORE THAN ONE ORBIT IS REQUIRED FOR AN ENTRYWAY, THE LEFT-TO-RIGHT SPACING IS DETERMINED AS WOOD FLOORING SHOP DRAWINGS/SAMPLE SUBMITTALS: FOLLOWS: - THE UNITS WILL BE MOUNTED SUCH THAT THE SEPARATION BETWEEN ANY TWO UNITS IS EQUAL TO WDF-1 ANDERSON HARDWOOD P_CRAF D H HICKORY, VIRGINIA VINTAGE, 1 THE CONTRACTOR SHALL SUBMIT EITHER SHOP DRAWINGS OR DATA SHEETS FOR THE FOLLOWING ITEMS THE ENTRYWAY WIDTH DIVIDED BY THE NUMBER OF UNITS MOUNTED IN THE ENTRYWAY. COLOR: FLINTLOCK, HANDCRAFTED HICKORY, 1/2" THICK, 5" WIDE WHEN THEY FORM A PART OF THE WORK: MISCELLANEOUS METAL WORK - THE UNITS ON THE ENDS OF THE DOORWAY WILL BE MOUNTED SO THAT THE DISTANCE FORM THE VINYL FLOORING ORNAMENTAL METAL WORK ORBIT UNIT TO THE SIDEWALL IS EQUAL TO THE WIDTH OF THE DOORWAY DIVIDED BY TWICE THE NUMBER OF UNITS INSTALLED IN THE ENTRYWAY. HARDWARE DOORS AND FRAMES VCT-1 ARMSTRONG EXCELON, WASHED LINEN #51810 w MILLWORK AND CASEWORK FOR EXAMPLE, FOR A 20' WIDE DOORWAY REQUIRING TWO UNITS, THE UNIT ON THE LEFT WILL BE MOUNTED Z SPECIAL DOORS, WALLS, SCREENS OR PANELS 5' FORM THE LEFT SIDE WALL, THERE WILL BE A 10' SEPARATION BETWEEN THE UNITS, AND THE UNIT ON TOILET PARTI110NS AND ACCESSORIES THE RIGHT WILL BE MOUNTED 5' FROM THE RIGHT SIDEWALL EIGHT FIXTURES TILE FLOORING Z EXIT SIGNS IF THE STORE WILL HAVE A HARD CEILING, PLEASE INSTALL JUNCTION BOXES 1"-2" AWAY FROM THE 0 AIR DIFFUSERS, AIR BARS OR STRIPS RECOMMENDED ORBIT LOCATIONS SPECIFIED ABOVE. i H APPLIANCES T-1 3 I TJ�GRADE TILE. �o SPECIAL EQUIPMENT STAR TOPOLOGY; P b E OR TENANT'S APPROVAL. PLUMBING FIXTURES FOLLOW THE GUIDELINES FOR INSTALLING A MULTIPLE ORBIT 5 NETWORK AS DESCRIBED ABOVE TO DETERMINE T-2 1" ,�CCD 2 SAMPLES: THE NUMBER OF ORBITS REQUIRED, AND THEIR MOUNTING LOCATIONS. P ECT9GRTOI�FOR TENANT'S APPROVAL. e C N N Eo M al U PAINT (DRAW-DOWNS OF ALL COLORS) A HOME RUN CABLE WILL BE RUN TO EACH ORBIT FROM THE SHOPPERTRAK HOST LOCATION. CHECK WITH T-3 7/8" SQUARE MOSAIC TILES. COLOR: GREEN. p S 0 al coo,Z FABRICS, WALL COVERINGS AND WINDOW COVERINGS SHOPPERTRAK OR THE CLIENTS STORE SYSTEMS GROUP TO DETERMINE THE SHOPPERTRAK HOST LOCATION. PROVIDE SPECIFICATION FOR TENANT'S APPROVAL. J E c rn ORNAMENTAL METAL FINISHES IN MOST CASES, THE HOST WILL EITHER BE A MODEM OR TCP/IP TO RS485 SERIAL CONVERTER, INSTALLED GROUT: POLYBEND /19 PEWTER p COE N ALUMINUM FINISHES NEAR THE TELECOM BOARD, STORE CONTROLLER, OR NETWORK SWITCH. V Of < TILE. FLOOR, CEILING, CERAMIC OR WALL T^4 7/8" SQUARE MOSAIC TILES. COLOR: WHITE 6 'i + GLASS dl: FRAMES LEAVE 15'-20' OF CABLE COILED UP AT BOTH ENDS OF EACH RUN. PROVIDE SPECIFICATION FOR TENANT`S APPROVAL. lei r w --Fz i` FINISH WOOD TRIM GROUT: POLYBEND #19 PEWTER m HARDWARE FINISH IN SOME CASES IT IS POSSIBLE TO DASIY-CHAIN MULTIPLE UNITS AT THE END OF EACH HOMERUN. HOWEVER, - ° o CARPET THE 1500'/N RULE STILL APPLIES. IN OTHER WORDS, THE IF RUN LENGTH WILL EXCEED 1500' DIVIDED BY THE T-5 3" E GREENWICH VILLAGE, WHITE. fj o STONE NUMBER OF ORBITS, THE RUN MUST BE BROKEN UP INTO TWO. PI E FOR TENANT'S APPROVAL. I c a T-5 1 A MARBLE TILE. J Z M 3 THE ABOVE LISTING DOES NOT LIMIT SUBMITTALS THAT MAY BE REQUIRED BY 1HE ARCHITECT OR OTHER ORBIT CABLE SPECIFICATIONS: p � OR TENANT'S APPROVAL. �� n o CONSULTANTS RETAINED BY THE OWNER. m r7 00 CATEGORY 5 CABLE W 4 THE OWNER'S REVIEW OF THE FINISHES, COLOR AND OTHER AESTHETIC MATTERS INCLUDING SHOP WALL BASE MATERIALS E DRAWINGS AND SAMPLES IS ONLY FOR THE CONVENIENCE OF THE OWNER IN FOLLOWING THE WORK. OWNER'S 4 PAIRS, 24 AWG, SOLID CONDUCTORS, TWISTED PAIRS, 7X32 TINNED COPPER, 12.5 Pf, 110 Ohms, CL2, • REVIEW SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ANY DEVIATION FROM THE PLENUM RATED. J REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE OWNER'S REVIEW SHALL NOT BE CONSTRUED AS A COMPLETE CHECK NOR SHALL IT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS OF ANY SORT BERK-TEK CABLE - #230247 (SOLID PLENUM) WB-1 3/4" X 4" WOOD BASE PAINTED P-2. IN THE SHOP DRAWINGS OR SCHEDULES, OR FROM THE NECESSITY OF FURNISHING ANY WORK REQUIRED BY BELDEN CABLE - #1701A (BONDED, SOLID TWISTED PAIRS, PLENUM) c THE CONTRACT DOCUMENTS WHICH MAY HAVE BEEN OMITTED ON THE SHOP DRAWINGS. THE OWNER'S REVIEW WB-2 4" BURKE, /523 BLACK BROWN O_ OF A SEPARATE ITEM SHALL NOT INDICATE REVIEW OF THE COMPLETE ASSEMBLY IN WHICH IT FUNCTIONS. W) 5 THE ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES WITH REASONABLE PROMPTNESS AND WILL CEILING TYPES W RETURN THEM TO THE CONTRACTOR WITH THE ARCHITECT`S STAMP APPLIED THERETO. NOTATIONS BY THE 0 ARCHITECT WHICH INCREASE CONTRACT COST ON TIME OF COMPLETION SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION BEFORE PROCEEDING WITH THE WORK. EACH SUBMITTAL WILL BE STAMPED INDICATING CLC-1 24" X 24" ARMSTRONG ACOUSTICAL CEILING TILE, FINE FISSURED, TEGULAR. e e Tl THE APPROPRIATE ACTION AS FOLLOWS: CLC-2 SUSPENDED 5/8" TYPE 'X' ACOUSTICAL CEILING TILE, PLATE /320 0'X' GYP. BD. CEILING W/ SMOOTH FINISH. CLCr3 2 SFUSE MS / A "NO EXCEPTION TAKEN" MEANS THAT THE FABRICATION, MANUFACTURE, OR CONSTRUCTION MAY V } PROCEED PROVIDING SUBMITTAL COMPLIES WITH THE CONTRACT DOCUMENTS. B "MAKE CORRECTIONS NOTED" MEANS THAT FABRICATION, MANUFACTURE OR CONSTRUCTION MAY WALL TILE Q m PROCEED PROVIDED THE SUBMITTAL COMPLIES WITH THE ARCHITECT'S NOTATIONS AND THE CONTRACT Z DOCUMENTS. IF FOR ANY REASON THE CONTRACTOR CANNOT COMPLY WITH THE NOTATIONS. THE CONTRACTORLL Q A SHALL RESUBMIT AS DESCRIBED FOR STAMPED "DO NOT USE". WT-1 3"�Xj��PL1�UBWAY TILE (POLISHED/GLAZED FINISH) G L11�,T1C DUSTY GREY C "REJECTED" MEANS THAT THE SUBMITTAL DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS WT-2 3" TILMWSUBWAY TILE (POLISHED/GLAZED FINISH) AND THAT THE FABRICATION, MANUFACTURE OR CONSTRUCTION SHALL NOT PROCEED. SUBMITTALS STAMPED GFAO "REJECTED" ARE NOT PERMITTED ON THE JOB SITE. CONTRACTOR SHALL MAKE REVISIONS AND RESUBMIT. S`���D .9R�y/ D "REVISE AND SUBMIT" MEANS THAT THE SUBMITTAL DOES NOT COMPLY WITH THE CONTRACT FINISH NOTE I I rH T� DOCUMENTS AND THAT THE FABRICATION, MANUFACTURE OR CONSTRUCTION SHALL NOT PROCEED. THE SUBMITTAL SHALL BE REVISED AND RESUBMITTED. THE REVISED SUBMITTAL SHALL REFLECT THE ARCHITECT`S ALL INTERIOR WALL, CEILING AND FLOOR FINISHES, DECORATIONS AND TRIM SHALL NOTATIONS AND THE CONTRACT DOCUMENTS. COMPLY WITH NEPA-101:36.3.3 2009 EDITION, AND IBC CHAPTER 8 1/5/15 �COTTSDALE.AZ E "SUBMIT SPECIFIED ITEM" MEANS THAT THE SUBMITTAL DOES NOT COMPLY WITH THE LATEST v, WN O� REVISIONS TO THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL REVIEW THE LATEST CONTRACT DOCUMENT REVISIONS AND RESUBMIT THE ITEM SPECIFIED. 9�F OF Q�1� DATE: ,2/25/14 SHEET: S P4 ?am o AS NOTE DRAWN B'(: N.R. S PROJECT No.: 320103498 COPYRIGHT NOTICE: GENERAL NOTES these drawings and specifications are copyrighted and subject to copyright protection as an 'architectural work' under sec. 102 of the copyright ad, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the awsroll form, arrangement and REVOVE ALL ITEMS AS INDICATED ON PLANS. composition of spaces, and elements of the design. Under such protection, unauthorized use of Mese 2. CARE SHALL BE TAKEN DURIN6 DEMOLITION SO AS NOT TO DAMAGE OR ALTER ANY EXISTING drawings and builspeding may /orresuin cessation of construction, builtlinq ssizuro, and/or monetary liability. STRUCTURAL MEMBERS. THE ARCHITECT AND KIEHL'S PROJECT MANAGER SHALL BE NOTIFIED IMMEDIATELY IF ANY DAMAGE OCCURS OR IS DISCLOSED DURING DEMOLITION. S. IN ALL WALLS AND CEILINGS THAT ARE REMOVED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADJACENT TENANT DISCONNECTING AT SOURCE AND REMOV N6 OR GAPPING ANY ELECTRICAL, PLJM'BIN&, GAS LINES AND MECHANICAL DUCTWORK THAT IS DISCLOSED AND NOT SCHEDULED FOR REUSE. REROUTE AND CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR ADJACENT BUILDING AREAS T-AT ARE NOT IN �,-T„ 2 1/4." 34,_10 5/6" 18'-2 1/6' THIS CONTRACT. Al 4. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT 15 TO BE REMOVED SHALL BE DISCONNECTED AT 3 4 LEASE LINE TO LEASE LINE V.I.F. LEASE LINE TO LEASE LINE V.I.F. SOURCE AND REMOVED. _.. O 5. ALL OAS, WATER AND DRAIN LINES SUPPLYING EQUIPMENT THAT IS TO BE REMOVED SHALL BE _ DISCONNECTED, REMOVED AND GAPPED ABOVE CEILING OR BELOW FLOOR. IF CONTINUITY OFr -- SYSTEM MUST BE MAINTAINED FOR USE BY ADJACENT AREAS, CONTRACTOR SHALL REROUTE, A5 I L - - -- -�_ - - 15 r 8 e I 3 MALL STARS '-- - � _ W L NECESSARY, TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPIN6J I I - I 2 4 a O M j 3 17 12 I O 2 10 cosa'ee 1" V 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVIN6 FROM THE SITE, ALL RUBBLE AND DEBRIS J 1 15-b A.F.F. 10 I IA CAUSED BY DEMOLITION, AND 0ISP051N6 OF IT PER LOCAL, STATE AND/OR FEDERAL i �. eE; s� J J 3 4 --- J .(', o 3 I� . _. a 20 6 REQUIREMENTS. O a • • J Cr T. DEMISING PARTITION WORK TO BE REMOVED SHALL BE PERPORMED IN ACCORDANCE WITH J O e —� _I e O D — — — .... ........ LANDLORD'S CRITERIA. ALL INTERIOR DEMOLITION WORK TO BE BY TENANT'S O.C. 1 12 I 6 18 I 6 D. REMOVE OR RELOCATE ANY SPRINKLER LINES, AS REQUIRED, IN FIELD PER LANDLORD'S AND/OR :�`�' " LOCAL AUTHORITY APPROVALS. a� _— �i\. - - - 2 - - - 1a T n� v�����ce 0000a. .r.. �� .. :" �� -. . 'MM � � E mss a o�� .�� � � �� 16 9. 6ENERAL CONTRACTOR TO COORDINATE WITH THE KIEHL'S PROJECT MANA&M AND ARCHITECT AS I(1 „� e —�^� 1040 TO THE DISPOSITION OF ALL ITEMS TO BE REMOVED. 4U 17 /. - - -f- '� I- - - T - 4 / 15'-II" A.F.F. - �\ }�srlaw .. ...... ___.. IO. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL GEILIN65, WALLS AND FLOORS, AS r / I I !�_\O I -./ / �\ I \I \\ -. I - - - - L REQUIRED, TO RECEIVE NEW FINISHES. (b.G. TO MAINTAIN I-HOUR FIRE RATED CONSTRUCTION I I O ;4) O i L �/�-��Z THROUGHOUT TENANT'S SPACE WHEN REQUIRED). n / / e > r n ■ N _21 11. CONTRACTOR SHALL PROVIDE AND MAINTAIN A MIN. OF 1-2AI0150 FIRE EXTINGUISHER WITHIN -j5'-0" 5 - ^ \ _ \ _ LEASE LINE TO LEASE LINE V.I.F. n OF AORK / PROJECT AREAS, UNLESS OTHERWISE DIRECTED SY THE FIRE MARSHALL. _ _ _ , 12. WHEN REQUIRED, CONTRACTOR SHALL PARTICIPATE IN RECYCLING PR06RAM TO REDUCE WASTE TO I I e )� J L N 0 1 1r/4 - I \.... 8 LANDFILLS. CONTRACTOR TO VERIFY REQUIREMENTS A/ THE OWNER AND LOCAL JURISDIC-ION. LV I I I / 12 a 1. - - -. -..I j II 12 / 1 2 C Z B. O.C. SHALL NOT GUT OR DISTURB EXISTING STRUCTURAL SYSTEM. THE b.G SHALL = I e11 0 18 I { O ,0 12 h I 3 X-RAY/PACHOMETER SLAB TO DETERMINE IF POST TENSIONED SLAB OR IF DESIGN IS IN CONFLICT 1 O O �` I II I / 1 L — 4 lu lu O G.C. REMOVAL SUMMARY " I I � - /�/ I " W +� ■ \ / I 11 Q J GENERAL CONTRACTOR AND/OR SUBCONTRACTORS SHALL REVIEW THE EXISTING FACILITY TO V I� I O „ y/ off`\ //��0 �� O i I { ADJACENT TENANT — a� ■_ (/� O DETERMINE THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE NEW WORK. A WRITTEN OUTLINE A� Q 1 I 1 \ / X �. OF ALL REQUIRED DEMOLITION SHALL BE SUBMITTED TO THE OWNER DESCRIBIN6 THE FOLLOWING J r w 1 II I x \ / / • 1 , A (BUT NOT LIMITED TO). J �D A 1 111222 \ N L l V 2. CONDITION OF EXISTING POWER PANELS AND TRAN5F0¢V_RS; FEASIBILITY FOR RELOCATION AND OF 1 L I le // \\ \Ix 11 12 L_ � /�/�� 00 M REFURBISHING, OR NEED FOR REpLAGEMENT DUE TO AGE OR EXISTIN6 CONDITION. VLn CL 0 LLI �� I 12 \ / � 4'-0 1/6" A ■Y 3. CONDITION OF EXISTING SHEET ROCK ON EXISTIN6 DEMISING WALLS AND RECOMMENDATION OF tu1 I O \ I5'-R" A.F.P. _____ 12 - i _ {_ a Q NHETHER TO REMOVE EXISTING OR REUSE TO BE DETERMINED IN FIELD. 4 I 5 IXXEX(E) O O O OLn 4. CONDITION OF EXISTING MECHANICAL SYSTEM; FEASIBILITY OF REUSIN6, RELOCATION, OR RERURSISHING EXISTING EQUIPMENT AND DUGTAORK; AND RECOMMENDATION OF REPLACEMENT, IF 4 ¢, • • • NECESSARY, PRIOR TO BID. \ 19 e o e e e 12 5. SUMMARIZE RECOMMENDATIONS POR REUSE OF EXISTING MATERIALS, EQUIPMENT AND ACCESSORIES, I - - -- - - ONCE REFURBISHED TO A LIKE-NEA CONDITION, ITEMIZE THE CREDIT TO THE CONTRACT. IJ/e 6. ANY UNNOTED EXISTIN6 CONDITION WHICH CONFLICTS WITH THE PROJECT REQUIREMENTS AND MAY I O O re Te- -- -e - J ---e- - -fie REQUIRE MODIFICATION, RELOCATION OR REMOVAL TO COMPLETE THE PROJECT SHALL BE L - - - - - - - - - - - - - - - - - - - - IDENTIFIED SO THE NECESSARY DRAWIN6 REVISIONS MAY BE INCORPORATED INTO THE PROJECT L - - _ - _ - _ - ------ _ _ - _--_----���� - REQUIREMENTS. 5 4 m SINCE 1 8 5 1 a s 30'-5 3/4" 6 I/4" m LEASE LINE TO LEASE LINE V.I.F. n KEYED NOTES MALL CONCOURSE 1O EXISTING STRUCTURAL COLUMN TO REMAIN - S__ SHEET Al. O.C. TO VERIFY EXACT LOCATION IN FIELD. MAINTAIN EXISTIN6 FIRE FROOPIN6. REMOVE EXISTIN6 FINISH DOWN TO DRYWALL w SURFACE , PATCH AND REPAIR TO A SMOOTH SURFACE READY TO RECEIVE NEW FINISH PER z PLAN. 2O REMOVE EXISTIN6 FLOORING MATERIALS FROM CONCRETE SLAB, E6: TILE, CARPET, TACK w STRIP, ETC. PATCH AND REPAIR SLAB TO A SMOOTH FINISµ READY TO RECEIVE NEW FLOOR DEMOLITION PLAN Z FINISHES. CAREFULLY REMOVE MALL TILE TO RE-USE AND REPLACE ANY DAMAGED TILES z DURING CONSTRUCTION. O3 EXI5TIN6 DEMI51N6 WALL TO REMAIN. REMOVE EXIST NO WALL PINISHES DOWN TO ORIGINAL SCALE: I/4"=1'-0" a DRYWALL SURFACE. (It. PANELING, WALL COVERING, SLAT WALL ETC) PATCH AND REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISH AND FIXTURES. sj, u) uvi E 4O LEASE LINE !_ °' N N o SO EXISTING STOREFRONT TO BE REMOVED IN ITS ENTIRETY. R m 00 Jam vsm 0 1n o ("C � O6 EXISTIN6 INTERIOR PARTITION TO BE REMOVED. No. J �� O7 TEMPORARY BARRICADE WALL, COORDINATE W/ MALL CRITERIA. SEE BARRICADE NOTES U a a T � � LL ABOVE. _ ' N 8O EXISTIN6 NEUTRAL PIER TO REMAIN. 9O FAIR OF KEYED BARRICADE DOORS. ALIGNED WITH EXISTIN6 STOREFRONT OPENING. o 00 10 L U N COORDINATE WITH MALL CRITERIA. J Z rn 10 EXISTIN6 GEILIN6, LI&HTIN6, 5PEAKERS AND DIFFUSERS TO BE REMOVED, PROTECT EXISTIN6 �10 o SPRINKLER HEADS. 1 1 0) 00 W G EXI5TIN6 DUCT TO BE REMOVED. + 12 EXISTIN6 FIXTURES TO BE REMOVED. ~ J 13 EXI5TIN6 SOFFIT TO BE REMOVED. G 14 EXISTIN6 SHELVES TO BE REMOVED. C O 15 EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED. 1n G UJ 18 EXISTIN6 DOOR AND FRAME TO REMAIN. REPAIR AS NECESSARY TO RETURN TO LIKE NEA 0 CONDITION, PREPARE DOOR AND FRAME TO RECEIVE NEW PAINT FINISH. SEE SHEET A5 FOR 0C FINISH . . a 17 EXI5TIN6 EXHAUST DUCT TO REMAIN. J9 18 EXISTIN6 PLUMBING TO REMAIN. i 0 19 EXISTIN6 ROOF DRAIN TO REMAIN. S 20 EXISTING PLUMBING AND FIXTURES TO BE REMOVED IN ITS ENTIRETY. �L 6 20 EXISTIN6 STRUCTURAL JOIST. t0 tD ,t,.t BLAIR S�C�f� LEACH aC SCOT17- ALE,AZO X15 0 NOTE: NOTE: NOTE NOTE DATE: 12/23/14 SHEET: B.G. SHALL VERIPY EXACT LOCATION OF ALL AL1_ ABANDONED MATERIALS, EVERYTHING TO REMAIN' MUST COORDINATE BARRICADE SCALE: D 1 STRUCB TURAL COLUMNS DURING DEMOLITION EV CES, F'XTURES ETC. TO BE BE BROUGHT TO LIKE NEW CONSTRUCTION TYPE AND LOCATION AS NOTED AND PRIOR TO PRAMIN6. CONTACT ARCHITECT ¢E`�OV.7 =ROM PREMISES AND , CONDITION WITH MALL OPERATIONS MANAGER DBAYYN W. A -- ANS 7SGREPANGES ¢OG=-c= N.R. ES 320103496 COPYRIGHT NOTICE: WALL LEGEND ADJACENT TENANT Thee drawings and specificationsroeioa are copyrighted and subject to copyright protection as an 'architectural work" under sea. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement an KEY SYMBOL (SECTION DESCRIPTION 2 I/4 cmposition of spaces, and elements o} the design. 2'-T' 34'-10 5/8" 13'-2 1/8" Unoder such protection, unauthorized use of these EXISTING DEMISING PARTITION. PATCH 6 REPAIR AS NECESSARYOdrawings and specifications may result in cessation of q FOR PROPER APPLIGATrON OF NEW FIN SHES. �- �� LEASE LINE TO LEASE LINE V.I.P. b 9/8' L.L. TO L.L. V.1.P. construction, building seizure, and/or monetary liability. I O 1/2 b'-10" 4'-O" 2'-2" 6 5/8" 10'-0 3/8" T-0 5/8" O e BRICK FINISH OVER I/2" DUROGK ON EXIS-IN6 DEM 5 N& WALL. RESTROOM NEW A.D.A. TOILET 5/8" GYP. BD. (STORAGE SIDE), I/2" DUROCK (SALES SID£) ON ROOM AND FIXTURES 5-5/8" 20 &A. METAL STUDS ® 16" O.G. RUN 6YP, 5D. TO TOP OR aAS - SEE SHEET A5.1 WALL OR 6" ABOVE T-BAR C£ILIN&. LEASE'NE 5/8" G"P. BD. (BOT- 5 DES) ON 3-5/8" OR 6" X 20 GA. M-L. STUDS OD 6 ® 16" O.G. RUN 6YP. 5D. TO TOP OF WALL OR b" ABOVE --BAR — — — ' CEl'.N6. USE WA-ER RESISTANT 6Y1" BD. IN ALL WET AREAS - F F I / / I MALL STAIRS G 1/2 DUROCK (ONE SIDE) ON 3-5/8" X 20 (SA. METAL S7JD5 ® Ib" - � � LM OE O.G. RUN GYP. BD. TO TOP OF WALL OR b" ABOVE T-BAR GEILIN6. �' _ % 0 1 W -- r- 19S J � O I N ' / Y In 7 5/8" TYPE 'X' bYP. 3D. (ONE SIDE) ON 3-5/8" OR 6" X 20 &A. -1 1\ O Ab ME-A_ 5-JDS ® Ib" O.G. RUN 6YP. 5D. TO -OP Ole WALL OR 6'' I _ \ / D n A ABOVE --BAR GEILIN6. In \` / Cr DOOR SCHEDULE J _ 74i, - —D-2 — J NON—SALES Q N KEY PE DESCRIPTION �\ r D i 4 o m Ab \ \ m AREA O A DOOR: PAIR 3'-O" X 'O'-O" HERGULTE 6LA55 DOOR OR EQUAL. tD �^ A 1 �� PROVIDE SwEC FIGATION FOR APPROVAL. 10'-8 5/8 — D-4 LOCK SET: PER DOOR MANUPAGTJRER, BRD5HED 5-AN:ESS STEEL \ _ A T CLOSER: DORMA, 5TS80, BRUSHED STAINLESS STEEL - Qy _ _ _ _ T:TIM M DOOR STOP: PLOOR MOUNTED, BRUSHED STAINLESS STEEL r \ `C 1 t 1 /� L PUSH/PULL: VERTICAL 24" LONb MALL SIDE, HORIZONTAL 36" LONG SALES SIDE, lr \ KJ n CD) - Mrn N SATIN CHROMIUM. D-3 1 Y 23'_8 /8" EXISTING MALL _ 111 •� PROVIDE SIGN ABOVE DOOR STATIN&: "THIS DOOR SHALL REMAIN UNLOCKED DURINGI NEUTRAL PIER. N.I.C. LEASE LINE TO LEASE LINE V.I.F. GC 5JSINE55 -OURS" PER 5 , -(TLE 8, SECTION 3235. / In 3 r 1 FD 2] C DOOR: 3'-O" X I-3/4" FIOLLOW METAL DOOR I a I SALES N a W/ HOLLOMETAL FRAME N Ab HINbES: I I/2 PAIR, 4 I/2 X 4 I/2, STANLEY, #F55174 FULL MORTISE, 626 SATIN CHROMIUM I I J LOCK SET: SGHLA6E, D SERIES, PRIVACY LOCK, ATHENS LEVER TYPE, I �� W O 626 SATIN CHROMIUM O I -8 I/4 Jl O O CLOSER: NORTON, 7500, STAINLESS STEEL ) D-1 I o n I DOOR STOP: '.VES, #436, SATIN CHROMIUM u Z I \ a T D-3 B µINbES: SATIN G -° X 3/4" WOOD DOOR AND FRAM£ _ Ill V I I LLrw 11/2 PAIR, 41/2" X 41/2" STANLEY, MODEL #P5MI FULL MORTISE, 626 dJ U1 ADJACENT TENANT y = N CHROMIUM r J , I •— Z LOCKSET: SCHLA&E, D SERIES, OPPIGE LOCK, ATHENS LEVER TYPE, J J I t M W 626 SA-IN CHROMIUM, PROVIDE KEYPAD SECURITY LOCK 1 O QLA CLOSER: NORTON, 7500, STAINLE55 STEEL. ~ I u DOOR STOP: :VES, #436, SATIN CHROMIUM cc M ' n u _ In 0. O - EXISTING EXISTIN& DOOR AND FRAME TO REMAIN. REPAIR AS NECESSARY TO I I I -4' 4-0 I/8 D-4 RETURN TO LIKE NEW CONDITION, PREPARE DOOR AND FRAME TO RECEIVE I I40 Q NEW PAINT FINISH. SEE SHEET AS FOR P'NISH I I EXISTIN& COLUMN. 6C A Q I\ TO VER MY N FIELD n a, — — — — — — — — — — — A I DOOR TYPES I 5 - A ---- 0 11 F Ab E I NEUTRAL PIERLN.I.C. wee, NOTE _— SEE SHEET A5. FOR ACCESSIBILITY 4" 3'-0" 5 6NA6E AND R£OJIREMEN-5 ALEN — — - - — — — — — — — — LEAS- LINE — — — — — — — — — — REQUIRED FOR 701-ET ROOM DOOR C E tl1 to S ' N BRUSHED STAINLESS STEEL 9 MALL CONCOURSE / - F'NISH, TYP. WOOD aRAME /2" TEMPERED WOOD DOOR 6LA55 DOOR LEVER TYPE r \ LEASE LINE TO LEASE LINE V.I.P. Z 7 3 D w Ab i v j O o ALUMINUM NT LAO © WOGD D°OR DIMENSION PLAN STOREFRONT DOORS AND FRAME � °C 3'-0" SCALE: NOTE ea m C-4 co CV 0° 516NA&EACCESSIBL£ SIM ENLARGED STOREFRONT P-AN, CO SHEET A4, FOR COMPLETE J � o rn STOREFRONT DIMENSIONINGN O o c Co HOLLOW METAL FRAME Q �"' _ �"" V 4 v 0. � Co U_ NOTE: LEVER � ;Q 1- PROVIDE SIGNS OVER DOORS r+ STA-IN& THIS DOOR TO REMAIN FOR FINISHES SEE FINISH SCHEDULE, SHEET SP4 o DOOR UNLOCKED WHEN 56lILDIN& IS - !D v OCCJP ED LETTERS TO BE HIGH - J 0 00 ON A G TRA5TIN6 BACKGROUND Z rn © HOLLOW METAL DOOR .. :...��_. ,::,, ^a In O AND FRAME1 � 1 d NOTE W PROVIDE TAG'ILE EXIT SIGN ON ~ AA-L ADJACENT TO ENTRANCE J DOOR NOTES °°R I. THE MAXIMUM ALLOWABLE FORCE FOR THE OPERATION OF EXTERIOR DOORS 15 5 POUNDS. NOTE O 2. 7-E CYLINDER LOCKS AND DOOR STOPS CAN NOT BE _OCALED N T-E REQUIRED SMOOT- NOTHING 15 PERMIT`"ED TO B£ .y KICK-PLATE AREA. ATTACHED -0, SJSPENDED FROM, UJ w OR PENETRATE THE ROOF DECK. O TENANTS NAY TOP ` ATTACH TO THE PLUMBING FIXTURE NOTES G� OF JOIST(S) OR TO THE • • _ IL STRUCTURAL STEEL. ALL WALL CONSTRUCTION SHALL BE = Y I. PJ5LIC R£S'ROOM5 PROVIDED BY MALL, SHALL BE WITHIN 300' OF STORE. SUPPORTED IN THIS MANNER. NO Q O WE-D'iNb TO OR SHOOTING INTO THE >- 2+ 5 N6 E OCCUPANT RESTROOM PROV DED FOR EMPLOYEES ONLY. STRUCTURE 15 PERMI-TED B. DRINK N6 Wf,­`ffR PROVIDED 5Y OWNER SJPP_IED WATER DISPENSING UN', 5EE SHEE- A2. Q16 Q W LEGEND DESCRIPTION SYMBOL tiS��Re DixsRC�� WALL �� LEACH SECTION XO OC, SYMBOL SETAIL MBOL e SCOTT6D4ALE.AZO Y X.X 9 DOOR SYMBOL E TF FINISH DATE: 12/23/'4 SHEET: SYMBOL XX-# SCALE. AS NO-ED A 1 DRAWN 6Y: N.R. PROJECT No.: ��� 320103488 COPYRIGHT NOTICE: FIXTURE PLAN NOTES These tlto co and specificationsectiare copyrighted and 2'—'�" 34'- Q 5/8" IS'—•s I/8" subject to copyright protection t an *architectural7u.S.C. swork under see. 102 of the copyright set, 17 u.S.C. As 10 LEASE LINE TO LEASE LINE V.I.F. L.L. TO L.L. V.I.F. amended december 1990. The protection includes, I. CONTRACTOR TO COORDINATE ALL SII—YELECTRICAL, VOICE/DATA, II REQUIREMENTS WITH without limitation, the ovarou Corm, arrangement and coder such ro spaces, and elements of the design. KIEHL'S SPGURITY VENDOR. CONTACT L'OREAL MATTHEW HAUbHTON - 908-b-13-3921 under such protection, unauthorized use of thus I" EQ. ADJACENT TENANT drawings and specifications may result in cessation of 2. CONTRACTOR TO COORDINATE ALL ELECTRICAL, VOICE/DATA, ETC. REQUiREMENT5 WITH K EHL'S " 2'-(�" construction, oufiding seizure, cnd/oma monetary liabmty. 3-O 8'-O" 3'-6" IT VENDOR. CON-ACT ADAM SAGHS AT ?32.951.4227. 3. CON-RAGTOR TO COORDINATE ALL -E_ECOMMJNIGAT ONS E_EGTRICAL, VO GE/DA-A, ETC. T REQU REMII WITH K EHL'S -E_MCOMMJNIGAT ONS VENDOR. CON-ACT LINDA GARBLE" AT RESTROOM '" 'T32.40O.26b4 4. I1V_ESS OTHERA SE NO-ED, ALL CA5 VETS TO BE CONSTRUCTED Oa 3/4" MDF., NIT- 3/8" MDP AT — — GAB NET BACKS IN AA_ MOUN-ED CASINE-'S. Ar EXPOSED EDGE5 Oa MDF. TO BE BANDED WITH II TAPE JNLESS OT-ERNISE NOTED. L O O O / / \ �y 0 5. ALL GAB VE- COMPONENTS TO BE SHOW SANDED TO 120 GRIT AND PAIN-ED PRIOR -0 DELIVERY TO > MALL STAIRS p JOB SITE. - J I 1 9 a•.n.as u. �' 6. CONTRACTOR TO REFER TO ELEVATIONS FOR OUTLETS TA66ED A5 LOCATED WITHIN MILLWORK FOR rD O Q A E 4 O // t O L EXACT LOCATIONS. F 10 m 10 0 T CONTRACTOR TO COORDINATE WITH KIEHL'S AUDIO VISUAL VENDOR FOR ALL SPEAKER LOCATIONS, J W RING DIAGRAMS, EQUIPMENT LOCATIONS AND RUNS, ADD'TIONA_ E_ECTRIGA . REQUIREMENTS, AND - - - ALL OT-ER I-EMS RELATED TO INS-A--A-ION Qa THE AUDIO VISUAL =ACKA6E. a NON-SALES Q O c Cr 6. ALL &-ASS SHELVES -0 BE lOrnrn TH CK, CLEAR, WITH POL SHED FRONT W&II U A4110eAREA9. ALL NTERIOR P-LAM AT CASEWORK TO BE AHITE; ALL DRAWaR SLIDES TO BE HW. PI WH-E; A— � J � w — — — Ql a s •s EXPOSED ED6E5 OF P-LAM TO BE BANDED WIT- AH-E EDbE -ASE. UNLESS O-HERWISE VOTE, FOR 5 • 6 8 8 8 ALL EXWOSED HA¢DNARE AND METAL - SEE SPEGIFICAT ONS. _ 'e O 111 1 10, ALL S-ELVES SHOWN S-IALL BE ADJUSTABLE UNLESS OTHERWISE NOTED AND SHALL BE 56PaOK-ED ti t \ — — — — O BY 5RASS S-ELa 'a NS ADJUSTABLE A71-1/2" IN Smm. 5Y5''EM -OLES DRILLED iN CABINET ENDS n UN_ES5 OTHERW SE VO-ED, ALL SOLID SyELVES TO BE 3/4 MDs. WITH I-1/2" PAINT &RADE P23'-8 /8" Cn HARDWOOD -Isa FOR 5-RENGTH. % 2 - - n L LEASE LINE TO LEASE LINE V.I.F. n 11. UVRED -ESS OTHEW BE VOT , ALL CAB NE75 TO BE CONSTRUCTED Oa 3/4" MDF., WIT- 3/8" MDP AT b CAB'NET BAGK5 IN NA-- MOUNTED GABIVE"S. ALL EX"'OSED ED&ES OF MDF. TO BE BANDED A-H N a EDGE TAPE JNLESS OT-ERAISE NOTED. UJ o 12. ALL FIELD Ae"PLIED CABINET 'R,M TO BE SHOP PRIMED PRIOR TO ',NSTALLA-ION; PA NTER TO PAINT N - - uu CABINET TRIM IN THE FIELD. cc K Z f w 13. ALL FIXTURES TO BE SECURED TO EACH OTHER AS REQUIRED TO RESIST LATERAL MOTION. j V r o 14. ALL FIELD APPLIED CABINET TRIM TO BE SHOP PRIMED PRIOR TO INSTALLATION; PAINTER TO PAINTuu Z \ o � •� CABINET TRIM IN THE FIELD. Z V O . O OL r ADJACENT TENANT NJ Jr+'� �� p J LL W 11 ° g 0---� °' B .= Vf = W y tt 41 M METAL SHELVING NOTE _ 4'-0 u - 0 0 a n h a SALES = �, a NEW SHEi-VINE TO BE PROVIDED AND INSTALLED BY 6C . TENNSCO OR EQUAL. BOLTLESS METAL RACKS Ln 0. 0 _ WITH 3/4" PLYWOOD SHELF. AT A MINIMUM STORA&E SHELVIN& WILL 5E 900 LBS/SHELF AND FOR O DOUBLE RIVETED BEAM T50 LBS/SHEEP. ALL 5TORA6E RACKS WILL BE SECURED TO THE WALL AND/OR t O 01 N Qu UM FLOOR TO PREVENT TIP1D'N6. RACKS WITH ADJACENT UN-S WILL BE BOLTED TOSETHER ACCORDING TO h 10 B MANUFACTURER'S REGOMMENDATION5. TH!5 SPEC IFICAT ON 15 N REGARDS -O THE METAL 57011111 Ell S MLV V6 UN -5 N THE BACK OF HOUSE )0!; Q O 0 6 • FIRE EXTINGUISHER NOTES .� I. &.G. TO aROV DE (2) VEA F RE EXT 46JISH (1) IN -HE S-ORAbE AREA AND (1) IN -HP R-aTA L AREA. .t MUL-IPJRPOSE DRY CHEMICAL TYPE. U_ RA-W 2-A: O:B:G, 10-5 NOM NAL CAPACITY N ENAME a 4" STEEL CONTAINER. 2. &.G. TO PROVIDE CAB NET FOR FIRE EX-IN&UISHER IN RETAIL AREA. MAKE: LARSENS'. MODEL: ry S I N C E 1 8 5 1 OCCUL- SERIES 0-2400 W-AIN-ES5 5-111 57AINLESS S-EEL 50-ID DOOR WITH 5-ACK TYPE A DIE GUT -ETTERING, STANDARD PU__ HAND-E. PROV DE 1 /L" SQUARE TR M "OR SEMI-RECESS. CABINET TO BE _OCA-ED 40 AFa MAX. TO THE TOP OF -HE CABINET. MALL CONCOURSE MILLWORK NOTES 30'-5 3/4" 951/41, I. MILLWORK FIX-JRES PROVIDED BY MILLAORKER, INS-A___D BY MILLAORKER. LEASE LINE TO LEASE LINE V.I.F. a- 2. Ar_ EXPOSED ED6E5 AND CORNERS SHALL BE SANDED, a LED OR O-HERWISE MADE SMOO-H "O uu �R_aVENT INJURY. PERIMETER WALL FIXTURE W ALARM SYSTEM LEGEND FIXTURE PLAN 3 - .e X " SELF-TAPPING SGREAS ?0 EACH STUD Z Un ME-AL STUDS o 16" O.G. MAX. Z TOTAL LEASE AREA: p32 5�. SCALE: /4 =1'-O" Z o z N N CONTROL -A\--- ® CE__J_AR / LR RADIO TOTAL SR_ES AREA: -l52 S.F a � / a W . © <Z—AP � -E�`qT� SENSOR TOTAL NON-SA-ES, AREA: 280 S. S-=L BACKING a-A-'E b" X Ib6A. PLA? SEE- ® -OLD Use / -ANIG L.NE GOND-IONER Y PLATE GOVT VJOJS FOR FULL "LINbT- OF WALL • E FIXTURES AND FIRST 5-JD BEOND C � N © 6_A55 BREAK DETECTOR UNINTERUPTED POWER SUP-LY - 5/8" bYP. BD. W m m m •6 X 2" SELF-TAPPING SCREWS. SEE MILLWORK E fA corm ® PIR MOTION SENSOR (GEILIN& MOUNTED) ® CAMERA POWER SUPPLY 1 SECTION FOR HEIGHT. (2) 5CREAS PER FIXTURE. ry © CONTACT SWITCH \ O Q ��2Sz 5 L_3: 5 CCTV LEGENDZgo FURNITURE AND FIXTURE SCHEDULE MILLWORK SCHEDULE \ / a " g KEY TYPE QTY. ROOM ROOM KEY ITEM QTY. REMARKS c W NFON MOV-OR AA-'ER GOO ER STORA&E OWNER OJTrT TO BE 6F PROTEG-'ED PERM - ANTIQUE FIXTURE MILLWORK 1 Z rn D161TAL VIDEO RECORDER O 0 VSTALLED O 1 MANUQAG-JR£R STEE_ BACKING PLATE MID MOUNTED HORIZONTALLY m m $'� 6.G. QER!METER LAIT MILLWORK BEHIND b`T. BD. RND W - --- - ---- OB 3MANUQAGTJIZ-R E ATTACHED WITH SCREW + �Q V DEO CAMERA (GEILIN& MOJNT=D) P RE EXT N&UISHER SALES 6 6.G. &C_ TO PROV DE BLOCKIV& N I- O 2 STORAGE AS REQUIRED.ETJ O EACH STUD. PLATE PERIMETER UNIT W/ BASE MILLWORK OBE CONTINUOUS FOR ALARM SYSTEM NOTES SEE FARE r FROM NOTES CO 4 = _ CABINET MANUPAGTJRER WIDTH OF WALL FIXTURES MINI STORAGE OWNER KEEP AWAY FROM ELEG. AND FIRST STUD BEYOND. C GA5H-WRAP MILLWORK MILLWORK MANUFAGI'URER � C 3O REPRI6ER�ATOR 0 NSTALLED PANELS COORD. WITH OWNER O 1 MANUPACJRER TO PROVIDE aLIP UP ADA O I. -HE &III 4- CONTRAG-OR 5 TO "ROV PE -WO (2) RJ3 LINES FOR -HE SECURITY PANEL. B" O.C. TO DETERM NE —OCA—ION. COUNTER 2. -HE &ENERA- GONTRAG-OR S TO WROV DE ONE (1) RJII L NE -OR THE DVR. M!CROAAVE STORAGE OANER KEEP AWAY FROM ELEC. GIFT MILLWORK 61 O4 0 NSTALLED PANELS COORD. WITH OWNER 0 0 MANUPAC JRER W r- BM 6.C. TO DETERM'NE _OGA-ION. O` CONDUIT NOTE AALLUNIT TO TRY MILLWORK "NIIt. SALES OWNER O WALL UNIT 1 MANUPAGJRER ■ ■ � a SO 1 INSTALLED T Y BY 6.G. � 36" NESTING TABLE 2 MILLWORK PERIMETER WALL GR GENERAL CONTACTOR TO PROW;DE 6 INSTALL ALL GONDU!T AND BOXES FOR SEGURTY, TELEVISION, - . MANUFACTURER 0 FIXTURE. ALL PEIf ' T. AND AND ANS OTHER LOW VOLTAGE SYSTEMS (AS REQUIRED BY CODE). A'!RIN& 15 TO Be VINTAGE SALES OWNER MOTORCYCLE TO BE T WALL FIXTURE UNITS TO V NESTING ABLE MILLWORK m1ZOV DED B� SEPARA-E VENDORS. VERIF� A_L W RE PULLS W/ VDEPENDAV- VENDORS. 6O MOTORGYG_E 1 INSTALLED SECURED TO THE FLOOR 5 2 MANUFACTURER -� BE GONTG'LD TO EACH 5" S.C. TO PREVENT TIPPIN6 ,p OTHER T"P Ii - . 41 TIMER NOTE EMP-OYEE STORAGE OrIVER HEALTHY SK'N AA__ 1 OWNER/ (3)S.C. T SHELVES, (U CREDENZA Q Q M 7O -OGKERS 0 VSTALLW O VENDOR . TO COORDINATE INSTALL WITH MILLWORK MANUFACTURER =RIOR -O AIR N6 TO ANE-5, METAL SH V N6 STORAGE 6.C. SEE ME-A- SHELVIN6 VO-ES C I/4" X TI N T MILLWORK THE ARCH-ECT WILL 5JBM - A -MER SG-EDJ E _ 5-NGT-OSE - b-- J 1 PIX-UR£S AND OU-LE75 TO BE CON-ROLLED B" T-E T MEQ. ELEC-'R G AN 'JS- R-aV'I£A ---=— SG-ED'J_£ GOVSJLTATION TABLE MANUFACTURER PRIOR -0 AIR N6. O 5 O SAMP.ES UNI- 1 MI ACM TURER �S� % D1x S. CHAIR CHAIR MANAGER OANER ,�� LEACH tr ELECTRICAL PANEL NOTES O 1 INSTALLED O �� PROMO TABLE 1 MILLWORK BY 6.G. MANUFACTURER MEN'S LOCKER MILLWORK I. VERIF" ALL OF T-E BREAKERS ARE (DENT PIED AND LA$ELED. MANAGERS DESK MANAGER b.G. SEE INTERIOR ELEVATIONS M 2 MANUFACTURER SCOTTSDALE,AZ AND SHELVES 2. 6.G. TO PROVIDE ?APE ON THE aLOOR AT 36" IN FRONT Oa THE E_EGTRIGAL PANEL. 10 ABOVE 1 O PHOTO BOOTH 1 MIALLR �, ^ W1;4 O 9 C CC) WALK—OFF MAT NOTE O BLACKBOARD TOTEM MILL,` °F � C � MANIPAG':JRE1F DATE: 12/23/4 SHEET: AALK-OaP MA- 5-ALL BE PROVIDED FOR ALL 57ORES KITH EN-RANGE PROM OUTSIDE. SUPPLIED BY O SAVE BAR 1 MILLMAWP JRaR OWNER, N57ALLED 5Y 6C. AS NO-'ED O GU5-°MERaAVEs 0 MANUFACTURERr�aEa no.: TYPICAL MILLWORK SECTION DETAIL PROJECT DRAWN N.R. A 2 1 1 oo NOTE: CONTRACTOR TO SUPPLY ALL BRACING AS REQUIRED. 320103498 SSS COPYRIGHT NOTICE: SALES These drawings and specifications are copyrighted and subject to copyright protection ca an architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, 61-511 without limitation, the overall form, arrangement and 2 1/4" composition of spaces, and elements of the design. 2'-7" 34'-10 5/8" Under such protection, unauthorized use of these u 13'-2 1/8" drawings and specifications may result in cessation of 201 A LEASE LINE TO LEASE LINE V.I.FL.L. TO L.L. V.I.F. V 10.I.F. L.L. construction, building seizure, and/or monetary liability. LO60 TILE AND SIZE T.BD. RESTROOM STOREA AGE AR 2 T4 ADJACENT TENANT FLOOR VCT-, PLoole VCT, _ — WALL BAS! W9"2 WALL DAM WR 2 M ALL WALL9 P-, A.J.W419 Pi "e GGILING CLG-t GBILINO CLS t RESTROOM In n t6 1 — ROWS IL \ MALL STAIRS o i SINGE Iasi (`+ T3 (2) T O = J I`IlLfll /'- RqK5cow Cr IIIII� J / — 5 O MOSAIC TO START AT v J N Q T3 T4 FRONT OF STOREFRONT L J CORRIDOR SYSTEM NON—SALES g W MALL TRAFFIC LEASE LINE \ O Q MOSAIC TILE FLOORING - r g i Cr. M 1 SCALE. I/2 -I O' LEI h LEASE LINE TO LEASE LINE V.I.F. LV A2.1 I IIA1 N ROLL-Ulm SECURITY GRILLE 1L O _ N 0 UI y� ' a CENTERLINE OP PROVIDE FLUSH AND o U1 91 T TRANSITION SMOOTH TRANSITION O I \ ,O �� O I/8" SGHLUTER STRIP AT FLDORIN6 � 1 F ■ L x FLOAT EXISTINS CONCRETE J A2I 1 ADJACENT TENANT M = (n SLAB WITH SELF LEVELIN6 Q ■� ENGINEERED WOOD CEMETITIOUS TOPPING r M a Go M In INS�RLATIONUPER AN mij MOSAIC TILE FLOORING O Q I I y Z MANUFACTURERS — _ RECOMMENDATIONS V l , w A 4'-0 1/8" Y l CL O Li. e aaa a a L%IOTIN9 COLUMN EXISTING CONCRETE SLABE'0n\j&L J, 14- = • �191s��v—eN—r 2 MOSAIC TILE TO WOOD FLOORING =tt S I N C E 1 8 5 1 SCALE: b"=1'-O" SALES AREA m LINES INDIOATG DIRECTION ar (il BOOR WDFI WOOD E A47VAL FA AND NOT TNG ACNAL PATTERN N AL1,WALL9 P-t MALLCONC URSE STORAGE SALES 30'-5 3/4" 8 I/4" W z LEASE LINE TO LEASE LINE V.I.F. S z a, ADA COMPLIANT FINISH PLAN D " TRANSITION STRIP, "SCHLUTER'' OR EQUAL SCALE: I/4"=1'-O" z w ENGINEERED WOOD ei; PLOO111I SLUE DOWN INSTALLATION PER e CD N 0 RECOMMENDATIONS MANUFACTURERS C t0 m aD Go Lcnl P-1 U VGT FLOORING E 0 a (n crn SEE FINISH PLAN / r J0 -aQcoo ° [LB CD w EXISTING CONCRETE SLAB FOR FINISHES SEE FINISH SCHEDULE, SHEET SP4 W r m. z CNIO �� L o Wm Cco YE co � E F- 3 MOSAIC FLOORING TO VCT FLOORING SCALE: 0 � O NOTE: V (A SAW GUT AND REMOVE CHANGE IN ELEVATION ACROSS ANY \ UJ SXISTINSAAENCH CUT SLAS POR THRESHOLD OR FLOORING TRANSITION SHALL w TRA5 REQUIRED NOT EXCEED 1/2" MAX � � CONCRETE SLAB ON GRADE .. • ■ � IL CORRIDOR 44 SI CONT. TO MATCH DEPTH OP EXIST., TOILET STORAGE SALES WITH •4 BARS AT 12" O.C. NOTE: _ t_ MALL TRAFFIC (TYP) ALL INTERIOR WALL, CEILING AND FLOOR Q O EX1571NS SLAB ON EACH WAY AT MIDDLE FINISHES, DECORATIONS AND TRIM SHALL L) >- 6RADE AS OCCURS DEPTH OF SLAB. DRILL 4 COMPLY WITH NFPA-101:36.3.3 20061 EDITION, PROVIDE FLUSH AND EMBED 4" INTO EXIST. SLAB. Q /r,/ 3 DOOR IN CLOSED SMOOTH TRANSITION AND FBG G-AFTER 8 5 `i POSITION AT FLOORING LOCATE PLUMBING ABOVE O TERRAZZO DOOR IN CLOSED VAPOR BARRIER � � z 2" X 1/4" RUBBER STRIP, BRUSHED POSITION NOTE: TRANSITION STRIP ALUMINUM FOR ACCENT WALL LOCATIONS, SEE INTERIOR CENTERED UNDER DOOR d ELEVATIONS ON SHEET AS MOSAIC TILE EXISTING MALL TILE � .. � . �cQ c`D A D��f VINYL FLOORING VINYL PLOORIN6. SEE FLOORING SEE SWDG Q SEE FINISH PLAN FINISH PLAN FINISH PLAN S _ — — — NOTE: �~ B LEACH its zzzzzzz_z r/ PRIOR TO NEW FLOORING INSTALLATION; G.G. —I—II III III III III III III III—III ll TO LEVEL EXISTING SLAB USIN6 SELF LEVELING a a ° o. a a. ° LI I III III I� = 11 L1 I� I I �I III—I - LI6HTWEI6HT CONCRETE MATERIAL, ARDEX GD a - - N' III III—I —III III—I III III III III—I —u r u I u n IT—I v5�15 e ° ACCORDANCE WITHL MANUFACTURERS WRNEA PLOOKIN& IN ITTEN t/3 6034 \\ OR EQUAL. ICT SCOTTSDALE,AZ \ FLOAT EXISTING INSTRUCTIONS AND RECOMMENDATIONS. NEW \_ FLOORING MUST BE LEVEL WITH EXISTING MALL EXISTING CONCRETE SLAB CONCRETE SLAB EXISTING GONCRE-E SLAB COMPACTED B`ILL AS CONCOURSE FLOORING. QF O �' WITH SELF LEVELING \. CEMETI TIOUS REQUIRED TOPPING VAPOR BARRIER TO MATCH EXISTING DATE: 12/23/14 SHEET: VINYL TO VINYL TRANSITION C� MOSAIC AT ENTRY ^^ SLAB DOWELING AT TRENCH D WNBY: AS NOTED A2 ■ 1 4 SCALE: N.7.5 0 SCALE: V.T.5 V SCALE: N.T.S. N.R. PROJECT No.: wIon o 0 320103448 LLSS 2'—T" 2 1/4COPYRIGHT NOTICE: ' 34'-IO $/$" 13'-2 /b" These drawings and specifications are copyrighted and L.L. TO L.L. V.I.F. subject to copyright protection as an "architectural work" LEASE LINE TO LEASE LINE V.I.F. under sec. 102 of the copyright act, 17 u.S.C. As arT� amended december 1990. The protection includes. without Imitation, the overall form, arrangement and composition of spaces, and elements of the design. RESTROOM ADJACENT TENANT v Under such protection, unauthorized use of thea. -41drawings and specificationss maymay result in cessation of aNON-SALES r construction, building seizure, and/or monetary liability. 3'-O" a•-W A.F.F. AREA '" NOTE: S"'RINKLER HEADS AT GYPSUM BOAR MALL STAIRS MEA ADJACENT A£ MUST BE FULLY M COVERED WITH NISHED TO / SURFACE. CENTER SPRINKLER HEADS IN CEIL'.N6 TILES WHERE 6 J I V / IQ APP-CABLE. O b F 6 6 NOTE: L 6 5U"POR' ARMS FOR LAY—IN CE V6 611l MUST NOT BE CONNECTED TO ANY OF THE It— OI ^�qj D ) �_ ® ELECCTRICAL, PLUMBING OR FIRE - . . ,,_ PROTECTION PIPING ORCr g:� NL __ .. Z 4 EQUIPMENT Z n D D 6 23'-81/8° i0 NOTE: % ?� +Io- ® -AL LEASE LINE TO LEASE LINE V.I.F. DATA GABLE TO BE RAN ABOVE O LA NOTE. SEE CAL9ECTRIEE C{ THE CEILING FROM EACH MOVING CEILINGLEGEND AND MECHANICAL SHEETS W _ a o- I SALES U1 L H BOX N THE i NDOW TO THE FOR MORE INFO. N h ` `t EQ. EQ, L 1 6 � ABOVE THEN G�L N6.NGAT b - N SYM DESCRIPTION REMARKS ai CABLE ABOVE Z v D D CLQ-2 D D ) CBEIL61NC6-UNTERMINATED. PULLED ■ri A CHANDELIER i Z u> O 12 `0 ( a► NOTE: :,,- .. .. ... NCA W RECESSED COMPACT FLUORESCENT Z F Y CASHWRAP OD DOWNLI6HT J D , `: b ADJACENT TENANT - 0 4 PAIR CAT b CABLE FROM - V _ _ _._ CASHWRAP TO MANA6ER'S AREA LOW VOLTAGE RECESSED ') p` D D D b PULLED B" 6.G. TERMINATED BY DI DOWNLI6HT J // EM I _.. - G�IEV O ■ O Q _._ �� O Lid DO LOW VOLTAGE RECESSED W 1, IL (NL) DOANLI6HT NI&HTLIGHT FIXTURE % 4,'-0 1/0" NOTE: ■ SAFE LOCATION TO BE VIEWABLE ■� U V IP F TRACK MOUNTED 3' 2L TSHO 4 ll r I' D F O BY CAMERA FLUORESCENT WALL WASHER u D 4-11 4'-6" 4-b lr � 6 6 F 6 66 t7 UM- p PAR 30 TRACK HEAD - WHITE D. a _ b'-0" In a O W H TIMER NOTES 2'X2' FLUORESCENT U ® DI _ DI .. .. I. LIGHT FIXTURES 'A', 'B','G', 'D', 'M', AND 'P' ARE TO BE ON A MAIN TIMER FOR NIGHT TIME LIGHTING. THE Hti JE SAAB TIMER WILL ALSO CONTROL ANY OUTLETS LOCATED NEAR MAIN DISPLAY WINDOWS IN RETAIL ji&f�' ® 2'X2' FLJORESCENT, VI6HTL bH- �D FIX JRE EQ. 2'-2�� EQ. 2. THE MA'.N T'.MER ''..S TO HAVE A SUPP�IMENTAL SHORT TIMER WHICH CAN BE SET BY THE MINUTE 'JP TO MALL CONCOURSE 4 m AN HOUR. THIS ALLOWS FOR THE LI&H'5 TO BE 5WITCHED ON AFTER THE MA'N TIMER HAS TRIPPED pl WITHOUT HAVIN& TO REPRO6RAM THE MAIN TIMER. ISOL17E COMPACT FULLY RECESSED h 410 MtN. WITH BATTERY BACKUP 3. EXTERIOR SI&NA&E IS TO BE CONTROLLED BY A PHOTOCELL TO TURN ON UNLESS OTHERWISE 30'-5 3/4" 8 I/4° INTRUCTED BY MALL. SI6NA6E TURN-OFF TO BE CONTROLLED BY SAME TIMER AS INDICATED IN NOTE I. SALES AREA EX SINCE 1851 ®L SINGLE FACE UNIVERSAL LEASE LINE TO LEASE LINE V.LF. 4. REAR EXTERIOR LIbHT AT EXIT DOOR TO BE CONTROLLED BY PHOTOCELL. NO TIMER. RECESSED EPCH IT RED LETTERS 5. A NIGHT LIGHT CIRCUIT IS TO BE PROVIDED. ®N COMBO OM EX T/EMER&ENC" LIGHT FIXTURE NOTE REFLECTEDCEILING PLAN ALL LIGHT FIXTURES ARE TO BE FRI BY CLIENT_ MIXTURES ARE TO BE INSTALLED BY THE GENERAL CONTRACTOR. oc �Q SEGJR� CAMERA FIXTURE POSITIONING NOTE W Z N STOCKROOM EMERGENCY LIbHT PRIOR TO PLACEMENT OF ANY LIGHT FIXTURES IN THE RETAIL AREA OF -HE 5T01 THE O.C. IS TO N S LOW PROFILE LED REVIEW POSITIONING OF EXIST;;V6 STRUCTURAL MEMBERS TO VERIFY CLEARANCE OF THOSE FIXTURES a W TO BE INSTALLED. u ac SPRINKLER NOTES M >1R 'A N E v � � CO CO HVAC SUPPLY AIR DIFFUSER I. ALL SPRINKLER HEADS IN RETAIL SPACE ARE TO BE CONCEALED. CAP ON 5PR'VKLER HEAD TO BE oGai FOR FINISHES SEE FINISH SCHEDULE, SHEET W4 W""� a Joy = ...._-. , ,;..... .. ....:. _ .....-.. ;'. . ..... .',.: ::. 2. SPRINKLER CONTRACTOR SHALL VER MY -HE LOCAT ONS OF 2 THE EXIS-IN6 S�RINK_ER HEADS. V Q I® VERIFY THE ADEQJACY AND CAPACIT`� OF THE SC VKLER HEAD PA-TERN. COORDINATE mai+ ! HVAC RETURN AIR DIFFUSER T � m LL IMPAIRMENT/SHUTDOWN WITH MALL OPERATIONS PRIOR TO ANY SUCH AC—IVITY. +_ w 0 Z � o NOTE. R t N Ill VERTICAL S—RUT, MAY NOTE: NOTE: NOTE: NOTE: NOTE: TILE SHALL BE J o CO BE STEEL STUD, BLACK �.RON, SPECIFY PERIODIC SPEGIA.. INSPECTION DURING THE BRACING E INSTALLATION SHALL WHERE SPACE ABOVE GEILIN6 5 USED AS A ANCHORS TO ATTAC» TO HEAVY DUTY 6RID - - �- - - --�- - - - "RESTRAINED" FIXED �� Lo M INSTALLATION OF SUSPENDED GEILIN6 SYSTEMS AND THEIR COMPLY W/ APPLICABLE 1 RETJRN AR PLENJM, STRUCTURE ABOVE AS RII IN D, E E F 0 ON (2) SIDE co EMT OR OTHER APPROVED i m m EQUAL 600D FOR UP TO ANGHOIll IN STRUCTURES ASSIbNED TO SEISMIC DESIGN SECTIONS OF ASCE 5 CHAPTER 13 WIRING/CONDUIT/GABLIN6/ETC SHALL BE = REQUIRED BY LANDLORD SEISMIC ZONES. Y , ___ __ W e+ v 4'-O" H'bH. CATE60RY D, E, OR F, ON THE 'STATEMENT OF SPECIAL CLASSIFIED FOR USE WITHIN PLENUM SPACE CRITERIA, - +— - - -� - - - - + r INSPECTIONS'. PROVIDE A COMPREHENSIVE SCHEDULE OF NOTE INSPEC-IONS FOR PERIODIC SPECIAL INSPECTION. NOTE: � (MAX LENGTH 4'-b'7 J ESR -1-TI' EXPANSION ...:..,._.. ___. _ .._..._. .. _-- E5Q-1545 'HILTI' EXPANSION = COMPRESSION S7RU"5 ANCHORS CONCRETE ANCHORS W2-0" O.G. EA. WAY R I—i 12 6A. WIRE SPLAYED IN ANCHOR TO FOUR DIRECTIONS ® 450 ® 1/2" EMT. COMP. STRUT T16HT TO STRUCTURE ABOVE. \ / CR MIN. CLEAR O 4'-0" O.G. EA. A4Y. 57RUCT. ABOVE. COMPESSION X - - OR MAIN RUNNER STRUT REQ D. AT EA. SEISMIC 2 GA. VERTICAL HANbER GR055 RUNNERUJ m RESTRAINT 12'-O O.G. EA. Y. WIRES a 46 O.G. EA. NAY. 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END _ _ _ _ O DASHED LINE INDICATES IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. - - —� 12 6A. VERTICAL WIRE 5/32" HOLE DRILLED FOR • ■ a HANGER ® 4'-O" O.G. EA. WAY, BOLT AND LOCK NUT HORIZONTAL DIRECTIONS ION TO INN AL Y TAP. AFTER GEILIN6 IS LEVELED HEAD PROVIDE ATLALLOWS EXIBLE GEIN6TT0 MOVE I" IN ALL SAN ;. _. O Z 12'-0" MAX TIE TWO ADJACENT WALL TO CIE N6 MAIN U 3/4" EMT 4'-0" MIN d CROSS, RUNNERS. 2 W/ 2' X 2" ANGLE 3 ARMSTRONG `t (4) 12 6A., 45° : PER ASCE T, SEISMIC r, C7 D,E OR F, 0 PRELUAGGOUSTIGAL TILE RESTRAINED CONDITION. CEILINS TYP, LAY WIRES AT A ES 45° SPLAY „ TEES AT 48" O.G. EVERY STRUT, WIRES AT 4'-0" DE CROSS 51° NOTE '2'-0" O.G. EACH O.G. EACH WAY. SUSPENDED CEI- LLI N65 - A WAY. HEAVY DU-Y T-BAR 6RID NOTE: .45° SYSTEM SHALL BE USED IN SEISMIC DESIGN CATEGORIES FOR GEILIN6 HEIGHT, SEE `_ MIN. 12 GAUGE WIRES. C��D A,p REFLECTED GEILIN6 PLAN - V Cy D THROUGH F (ASCE -! SEG BLAIR S. �fJ 15.5.6.2.2) A3 SUSPENDED V LEACH u F GEILIN6. NOTE 2 X 2" WALL ANGLE NOTE: REQUIRED AT ALL I. VERTICAL STRUT: A STRUT FASTENED TO THE MAIN RUNNER, SHALL BE EXTENDED d - WALLS SCOTTSDALE.AZ �15 FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. - _ J' 6034 THE STRUT SHALL BE ADEQUATE TO R-915T THE VERTICAL COMPRESSION INDUCED BY L FINISH THE BRAGIN6 WIRES. 2X2 CLOSURE ANGLE, FLOOR �� ❑ 5/8" TYPE X. MIN. SEE NOTE AT TOP. OF bYPSUM BOARD 2' X _XPOSED 6RID, LAY IN ACOUSTICAL ALL BE PLACED 2-O OR LESS O G IN a ELEVATION 2. THESE I-ORIZON-AL RESTRAINT POINTS 5"c�M ANY WALL. WI �.H TAPED JOINTS BOTH DIRECTIONS N:TH POINTS WITHIN b'-O SANDED SMOOTH. ARMSTRONG GEILIN6 PANELS. AS SPECIFIED PRELUDE XL 7-BAR 6RID SUSPENDED FROM ... 3a DATE: 12/23/14 SHEET: STRAIGHT MAIN STRJCT. ABOVE. S" MAX TEES 24" O.G. SW'E' A TYPICAL SUSPENDED ACOUSTICAL CEILING SUSPENDED GYP. BD. CEILING BRACING SUSPENDED T-BAR CEILING BRACING / SUSPENDED CEILING BRACING N.R.DRAWN UY. AS NOTED H _A` i 3 EV SCALE: N.T.S. V SCALE: N.-.5. SCArE: N.T.S. ■ SCALE: N.T.S. MMER No" 5201054a95 SUSPENDED GEILIN6 SYSTEM SHALL COMPLY WITH ICC 11 1505 GYP BD. CEI.iNb SHALL COMPLY WITH Cr,I11 12541 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an architectural work NEW 56" X 45' q O q under sec. 102 of the copyright act, 17 u.S.C. As CEVVZED ON A4.1 2 A4. A4. I amended december 1990. The protection includes. STOREFRONT II co hoot limitation, the overall form, arrangement and BOX BEAM composition of spaces, and elements of the design. 6—AZIN6 ABOVE FIXTURES Under such protection, unauthorized use of these @., A4. drawings and specifications may result in cessation of TVP. AT LINE OF S DOOR SOFFIT ABOVE construction, building seizure, and/or monetary liability. NEW �`!1a 1 > 9 n n LM �— LEASE LINE I I B TVP. AT I A4.1 A4.1 sroREFRONr A4.1Cr 2n 211 \2' b-I 2n Z" 6_g 2" •2n .Sit 510 OVISIBLE GLAZING VISIBLE 6LAZIN6 6 b VISIBLE GLAZING 2 8/8 4'-I ?/8" b.. b_gn b 'f-O b'O 01 ;orBOX BEAMS ABOVE EXISTING DEMISING M W NEW FRAMED STOREFRONT NEW 1/2" TEMPERED "CLEAR" PARTITION. PATCH AND bw COLUMN, BRUSHED STAINLESS 6LA5S STOREFRONT REPAIR AS NECESSARY STEEL FINISH, TYP. OLAZINO SYSTEM, 7Y1°. 2 TO RECEIVE NEW FINISH ■� _ A4 �/ ■ � � Q � a Z cn c� cc 1�= Q STOREFRONT PLAN C ;p 0 Z Z SCA-E: '�/2"= -O" O ■ CM3: cmd W O ■ UM t � as a � Q V) Mt 0 W �� � 0. 0H -J ImV) a LA W NOTE: NOTE: SI(SNA&E UNDER SEPARATE SIONA&E UNDER SEPARATE SUBMITTAL. SUBMIT 5I6N SUBMITTAL. SUBMIT SIGN • SHOP DRAWINGS TO SHOP DRAWINGS TO LANDLORD FOR APPROVAL - LANDLORD FOR APPROVAL PRIOR TO FABRICATION PRIOR TO FABRICATION UNFOLDED01 UNFOLDED FOR UNFOLDED FOR FOR CLARITY CLARITY CLARITY LEASE LINE SINCE 1851 514" 3-AGK 4 BLACK STAINLESS STEEL STOREFRONT q STOREFRONT FINISH TO BE EXISTING 3/4" EXISTING MALL METAL SIGN BAND, INSTALL FLAT AND EVEN, NJ AQ.,1 PAINTED SATIN BLACK, BLACK METAL STRUCTURAL COLUMN REVEAL NO OIL-CANNING, TVP. PAINT SPEC, TBD. REVEAL I Q � Ill uu Z *e4g SINCEQ 6 Z u'l a61851 SINCE 1851 w o N VI I w I CLIADaiN61 Iw�TESS'1-I BRUSHED o \ STAINLESS STEEL BELOW, \ u� v E c� ` ANN ° ld d) L _CO U J a cam J ) of< > tea + a _% LL Q Y Y 018 S U) U r U) O V J Z a) 0 1 CO 00 a)fill CO 00 + O .J O � � o L W C,1 0 0 11 1 AL is I Q Q: ai NEW ALUMINUM AND I/2" TES O . VERTICAL BR-1 Q Q M I/2" TEMPERED I/2' TEMPERED TEMPERED 6LAZ�N6 CLIP BR 1 6LA5S STOREFRONT CLEAR" 6LA5S CLEAR" 6LA5S 5PAGIN6 SHALL NOT "CLEAR" 6LA5S DOORS, BRUSHED STOREFRONT 6LAZIN6 STOREFRONT bLAZINb EXCEED 4'- OC., TVP. WITH GRAPHICS WITH GRAPHICS STOREFRONT GLAZING ESS STEEL FINISH. SYSTEM, TYP. SYSTEM, TYR. BY KIEHL'S SYSTEM, TVP. STAINLBY KIEHL I BRUSHED STAINLESS BRUSHED STAINLESS STEEL BRUSHED STAINLESS BRUSHED STAINLESS �c%U ARC* TYPE 'X' GYP. BD. BD. OVER 3-5/8' X 20 a. TYPE 'X' GYP. BD. TYPE X WISH ON 5/8" SV+ STEEL FINISH ON 5/b" FINISH ON S/8" TYPE X. 6YP. STEEL FINISH ON 5/8" STEEL F bYP. BD. ��S BLAIC S. f OVER 3-5/6" X 20941. METAL STUD FRAMING 9 OVER 3-5/8" X 20ga. OVER 5-5/8" X 2Oga. LEACH ��' METAL STUD FRAMING METAL STUD FRAMIN6 METAL STUD FRAMING SCOT TSDALE,AZ'V5�1S 6034 O� STOREFRONT ELEVATION 2 SCALE: 1/2"=17F DATE: 12/23/14 SHEET: SCALE: AS NOTED w DRAWN BY: N.R. H PROJECT No.: 520105488 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, TENANT TENANT LINE OF BASE BELOW compo tion limitation, the overall form, arrangement and composition io spaces, and elements of the design. TENANT I/2" FULLY TEMPERED Under such protection, unauthorized use of these NEUTRAL PIERdrawings and specifications may result in cessation of 5/6"FT TPE 'X' bYF. BD. OVER 6LAZIN6 construction, building seizure, and/or monetary liability. 2 LEASE LINE YWOOD SUB 1/2" FULLY TEMPERED 6LAZIN6 BASE BELOW SURFACE OVER METAL STUD 6LAZIN6 2"x4 1/2" MULLION 4 3/8" BOX COLUMN LEASE LINE 5/8" TYPE 'X' &YP. BD. 3 5/S" METAL STUD OVER 1/2" FRT PLYWOOD BOX COLUMN. SEE 3 5/8" METAL STUD BOX SUB SURFACE OVER 6/A4.1 (TYP) TOP AND BOTTOM COLUMN. SEE 5/A4.1 (TYP) METAL STUD BOX COLUMNPIVOT PER STAINLESS STEEL FINISH TO 8 5/&" TYPE 'X' 6YP. MANUFACTURER i TERMINATE AT CENTERLINE f0 BD. OVER /2" TEMPLATE OF 6LAZIN6, 1, 3 5/8" METAL STUD BOX COLUMN. FRT PLYWOOD _ _ _ ____ SEE 8)/A4.1 (TYP) SUB SURFACE OVER METAL LINE OF SOFFIT TENANT Z 3/S LINE OF BASE BELOW STUD BOX ABOVE COLUMN. SEE SHEET A2.1 AND STOREFRONT AS FOR FINISH DOOR IN FULL OPEN F051710N El . - ---------------------- n 10 /.1 BRUSHED NEW 3/4" X 3/4" BLACK METAL % LINE OF BASE STAINLESS STEEL 4A REVEAL AT NEUTRAL GAP BY �,, BELOW FINISH OVER 5/8" 6.G., TYP. BOTH SIDES OF GAP TYPE 'X' &YP. 50. (7" O MINES!BRUSHED STAINLESS STEEL 1/2" FULLY OVER 1/2" FRT FINISH OVER 5/6" TYPE 'X' L (�" L TEMPERED PLYWOOD SUB MALL M 6YP. UB SURFACE OVER OVER I/2" FRT 6LAZIN6 SURFACE OVER Go IM PLYWOOD SUB METAL STUD BOX BRUSHED STAINLESS 5'EEL FINISH OVER L Follow 5/8" TYPE BD. OVER 1/2" FRT BRUSHED STAINLESS STEEL FINISH OVER COLUMN METAL STUD BOX COLUMN 5/5" TYPE 'X' 6YP. BD. OVER 1/2" FRT PLYWOOD SUB SURFACE OVER METAL .E Q 6LAZIN6 BASE BELOW PLYWOOD SUB SURFACE OVER METAL STUD BOX COLUMN MALL LEASE LINE STUD BOX COLUMN ENTRY I� D MALL STAINLESS STEEL FINISH TO TERMINATE h Q AT CENTERLINE OF 6LAZIN6, TYP. M R: cc z DETAIL AT NEUTRAL PIER _/(� DETAIL AT STOREFRONT GLAZING_ DETAIL AT STOREFRONT ENTRY DETAIL AT NEUTRAL PIER OMCA O 0 *4 CA _ . LL. = Z — � � c� MEMOO 3 5/9"xl 1/4"x18 6A. 3 5/8"xl I/4"xl8 6A. EXISTING MALL WCV CONTINUOUS A5 METAL EXISTING MALL BULKHEAD (* � �E u 1[7 CONTINUOUS METAL O TRACK FASTENEa TRACK FASTENED WITH TE ANT MALL BULKHEAD NEW v2" x s/4" WITH >O SCREWS O.C.SCREWS AT 12" BLACK METAL � LU AT 12" o.c. O. LEASE LINE \ \ NEW K X TA REVEAL AT LU + 'H BLACK METAL am REVEAL AT MALL BULKHEAD BY STOREFRONT STOREFRONT BEAM. \ \ CEILING BY 6.G. - &.C., TYP. BEAM. REFER TO REFER TO CHART I/2" FULLY TEMPERED \ \ CHART BELOW. BELOW. 6LAZIN6 \\ \\ = `fl BLACK METAL SIMPSON 5/H2.5 CLIP EA STAINLESS STEEL F.R.T. BLOGKIN& AS \\\ \\ STOREFRONT SIGN SIDE. AI To FILL ALL REQUIRED \ SUSPENDED GYP. BAND, INSTALL HOLES WITH Flo SGEWS. \ \ BD. GEILINb FLAT AND EVEN, NO �°1■'��� F.R.T. BLOCKING AS REQUIRED � LL U J — ++ + I/2" GD PLYWOOD SDBOVER t' T OIL-GANNINb. TYP. ++ ++ 3 5/8"xl I/4"xl4 &A. SURFACE OVER METAL STUD L- I METAL STUDS ® S I N C E 1 8 5 1 + + METAL TRACK SILL �� l SI&NA&E BY FASTENED WITH X10 \v/ – SIGN VENDOR j I BOX BEAM. SCREWS AT 12" O.G. BRUSHED STAINLESS STEEL A41 (� -_ 1 20 &A. MIN I J SEE 5/A4.1 FINISH OVER 5/8" TYPE 'X' METAL STUD $ -- SOX BEAM SCHEDULE 6YP. BD. OVER 1/2" FRT FRAMING KEY SPAN J0157 SIZE. NQ PLYWOOD SUB SURFACE A4.1 OVER METAL STUD BOX F.R.T. BLOCKING BI 8'-O" - II'-11" (2) &"xl 5/8"x18 ISA COLUMN S2 12'-0" - IS'-II" (2) 5"xl 5/8"x18 ISA AS REQUIRED 53 I6'-0" - IQ'-II" (2) 10"xl 5/8"xlb 6A z 54 20'-0" - 21'-11'' (2) 12"xl 5/8"x14 6A B 55 (2) 3 5/8"xl 5/8"x14 6A. I I w 22'-O" - 25'-II" (2) 12"xl 5/8"x12 bA METAL STUDS f1 Il MALL FLOOR GYF. BD. CEILING f t NOTE: THIS DETAIL IS ONLY A DESIGN j j 11 CONT. 15 CPA. BOTTOMAT ENTRY PORTAL PAINT g GUIDELINE AND SHALL BE REVIEWED FOR f I I t TRACK W/ 'HILTI' DN ORTO MATCH P-I FULLY z '^ E. ACTUAL BEAM SIZE FOR EACH PROJECT. L-U--1 DS SHOT PIN INTO SLAB TEMPERED 6LAZIN6 8 3 5/8'x1 1/4"x16 6A. AT 24" O.G. META- TRACK ? -6YP. BD AT FASTENED WITH X10 INTERIOR BEYOND ,, ++■ >% rn � N E 5GREW5 AT 12" O.C. MALL V C o m ^ u CL to m COD STOREFRONT BEAM DETAIL DETAIL AT STOREFRONT GLAZING "' m MMI0 Al md;+SCALE: V.T.S. / SCALE: 3"=1'-O" ii■ ��, -100 LL m m � ria �9 J z0 M -1 -1 M-0 an O) WwCo IT 3 5/15" METAL STUD BOX O Z TENANT MALL E F- COLUMN. SEE 6/A4.1 (TYP) Q BRUSHED Z STAINLESS STEEL – STAINLESS STEEL FINISH TO LU O TERMINATE AT CENTERLINE E7u Few STTABRUSHED NLE55 STEEL FINISH BE OVD c OF 6LAZIN6, TYP. 0, FINISH OVER 5/8" TYPE 'X' 6YP. BD. v�J 1/2" FULLY TEMPERED OVER 1/2" GDX W w 6LAZIN6 PLYWOOD SUB LINE OF 57 BELOW SURFACE OVER METAL STUD BOX ■ d COLUMN Q T O ALUMINUM AND U &LASS y STOREFRONT Z T' ENTRY DOORS Q Q NEW ENGINEERED NEW ENGINEERED Wt D ARC WOOD FLOOR'N6, WOOD FLOORING, S` 9f SEE SHEET A2. SEE SHEET A2.1 BBAICH �� LEASE LINE BRUSHED STAINLESS STEEL FINISH OVER MOSAIC INFILL WITH TO 5/6" TYPE 'X' 6YP. BD. OVER 1/2" FRT FLOORING MATCH EXISTING, 5 -- MALL FLOORING 1/5/15 PLYWOOD SUS SURFACE OVER METAL SCOTTSDALE,AZ STUD BOX COLUMN A2.1 i vJ 6034EXISTINIS MALL EXISTIN& MALL O� 5/8" TYPE 'X' GYP. BD. OVER METAL STUDS iL FLOORIN6, N.I.G. A4.1 i j FLOORING, N.I.G. 9�F OF 03N� �---' ------ 'ilii-� uu DATE: 12/25/14SHEET: SI AS NOTED A4 . 1 zno 11 DETAIL SCALE: 3"=1'_0" 10 STOREFRONT GLAZING BASE SCALE: I" g DETAIL AT DEMISING WALL SCALE: =1b" pRAWNS :Y. NR ��� 320103448 COPYRIGHT NOTICE: HATCHED AREA INDICATES STEEL 5ACKIN6 These drawings and specifications are copyrighted and PLATE IN WALL. PLATE TO BE CONTINUOUS UNFOLDED UNFOLDED UNFOLDED subject to copyright protection as an "architectural work" TO THE FIRST STUD BEYOND THE LAST UNFOLDED under sec. 102 of the copyright act, 17 u.S.C. As PERIMETER FIXTURE. ALL PERIMETER UNITS FOR CLARITY FOR CLARITY POR CLARITY FOR CLARITY LOCATION OF amended december 1990. The protection includes, without limitation, the overall form, arrangement and TO BE FASTENED TO BACKIN6 PLATE AND P-1 p-7 "FORMULAS TO P-1 composition of spaces, and elements of the design. P-1 TO EACH OTHER - TYP. p 1 TRY" NEON Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. g _ � z 0000cc0000c � � Y F Q U m yF� o00000000c® - DERM n \ CrY N NEW WALL MOUNTED "F0R1-ULA5 TO TRY" 1A WB-1 WB 1 OWNER0STALL B XIE BB G.C. WALL MOUNTED SHELVES WB_1 r.-INTERIOR ELEVATION ANTERIOR ELEVATION 0 Z SCALE: I/4"=1'-O" B M = N O �- � Q UNFOLDED UNFOLDED UNFOLDED Im > FOR CLARITY FOR CLARITY FOR CLARITY N M P-1 P-1 P-1 P-1 P-1 P-1 P 1 P i -- - o O W GOLUNM O . wo COLUMN _ L O HSE WALL QWC Ln Zi p 100 M "� H LIM CLO Z MtAa i. WB WB I Xk —. D NTERIOR ELEVATION NTERIOR ELEVATION 40/"" SCALE: I/4"=1'-0" V SCALE: I/4"=1'-0" S I NCE 1 x 5 1 UNFOLDED FOR CLARITY uu EXISTING ELECTRICAL METAL SHELVING SLOPED z P_1 EQUIPMENT - SEE P-1 P-1 P-1 P-1 P-1 P-1 GEILIN6 ELECTRICAL PLANS z N O Z N V � T.T.B. T-- ____T-- ----T-------_i 1 -� 0 >, L Q E -1------1------1------J P-1 P-1 = P-1 ± C Caw N o O Q -- ---+- ----+ ----+ ----- O O > -0 O O 11 i li i � � � O O � C '� mm -----T -----T ------1 (n O m � o 16 L-------1-------1-------1-------J o OJ I J ¢ v +_------+ + yam. N N LL I I I I •� ! i — 0 T— T-------T l U O Cq NN _J NEW ELECTRICAL EQUIPMENT - 16 0 N WB-2 WB-p SEE ELECTRICAL SHEETS WB-2 WB-2 WB-2 WB2 wZ WB2 WB2 a rn - � o j a ELEVATIONJ F KL;ANTERIOR ELEVATION- oG NTERIOR ELEVATION- o FNTERIOR ELEVATI N SCALE, I,4' -O" (ONLTERIOR SCALE /4' -O' � a H0 0 Ww Y P-1 SLOPED Q / � 0 P-1 GEILIN6 V a wli. d Q aM L6 COMPUTER D 0 O 'mss B LA1x s�C�f,�+ LEACH tt' 111 SCOTTSDALE,AZ 6034 cC O'er FILE CABINET PROVIDE 2" DIA. 9�4t 0 O�v� FLAT SCREEN 6ROMMII 5" O.G. MONITOR WB-p FROM BACK WALL WB-2 DATE: 12/23/14 SHEET: K NTERIOR ELEVATION ANTERIOR ELEVATION SCALE: AS NOTI �C SCALE: 1/4"=1'-O" SCALE: I/4"=1'-O" DRAWN BY: J N.R. PROJECT No.: ��� 320103448 COPYRIGHT NOTICE: V VERTICAL These drawings and specifications are copyrighted and P subject to copyright protection as an "architectural work" 10'-0 1/4" MIRROR 39" 1" GRAB BAR under see. 102 of the copyright act, 17 u.S.C. As amended december 1990. if protection includes, 2" MARLITE without limitation,ofn, the overall form, arrangement and '-0 5/ " 5'-6" MAX. WAINSCOT TO composition ro spaces, and elements of the assign. q NTE: 1 Under such protection, unauthorized use of these ALL WOOD TO BE 48" A.F.F. TYR. drawings and specifications may result in cessation of FIRE TREI �� LAVATORY TOILET 42" GRAB BAR construction, building seizure, and/or monetary liability. INTERNATIONAL ACCESSIBILITY SYMBOL - �r RAISED i r /�� - - F�\ - - - - - X-- - t O 1 1/2" 1 1/2" = I , 6" _ P Q ( I l IN ' HOT W.H. NOT x I TO ENCROACH INTO f f T' MIN. WB-p Z h Z!N\ - FM TACLEARANCE AX OILET PAPER ODISPENSERRAB BAR DETAIL A5.1 � SPACE " GLR. FLR. MARLITE WOMEN 2 I \ / SPACE o LAVATORY WAINSCOT SCALE: 3"=I'-0" 5'-0" DIA. GLR TO 48" I ( / FLR. SPACE P_i P_1 A.F.F. TYP. /�� _ ELECTRIC % 36 ' HAND MIN IN II 6RRB , DRYER O a ® P ' X 60 ' ACCESSIBLE D_3 BAR / SOAP O O FLOOR RESTROOM Q DISPENSER y� SAGE SIGNAGE \\ I PAPER it T � - \ DISPENSER 1- o-3 i � CC Q 8"xl8" MIN. UNISEX GLR. FLR. \� FLUSH z \ N SPACE ® 516N \ F VAVLE ON f N W D OPEN SIDE NOTE: ■ �_ ALL WOOD TOBE 4'-I 5/4" 5'-0" 2'-10 5/4" Wg_p TO LE" W8-P 4" RUBBER i z ® z ®• FIRE TREATE> _5E ' BASE, TYP. NM O Q _ �: ENLARGED TOILET ROOM PLAN TOILET ROOM ELEVATIONS O N MEN WOMEN RESTROOM 1 A O L A ■ � � Z SCALE: I/2"=1'-0" 5G __. - -O �� � W O NOTES: LAVATORY ACCESSORY SCHEDULE .� N _ ~ I. PROVIDE ALL DRAINS, TRAPS, PLUM5IN6 AND OTHER ITEMS REQUIRED FOR A COMPLETE ITEM LOCATION MAKE MODELFH(-)VIULUREMARKS MC In V INSTALLATION INSTALLED BYy C t 2. PROVIDE BLOCKING FOR TOILET, SINK, GRAB ELECTRIC AMERICAN 0185 SATIN CONTRACTOR TO PROVIDE ALL BLOCKING AND LAVATORY CONTRACTOR BARS AND ALL OTHER ACCESSORIES AS HAND DRYER SPECIALTIES STAINLESS STEEL STANDARDS AS REQUIRED. M LU � � O -IM REQUIRED AMERICAN CONTRACTOR TO PROVIDE ALL BLOCKING AND PROPORTIONS SINK LAVATORY LUCERNE 0556.015 CONTRACTOR „ S. MAXIMUM REACH TO OPERABLE PORTIONS OF STANDARD STANDARDS AS REQUIRED. SINK TO BE WHITE. 3: � H a W W INTERNATIONAL SIGN OF ACCESSIBWTY 9 MIN. ACCESSORIES SHALL COMPLY WITH 2015 GBG FAUCET LAVATORY COMPANY rte-5004-LD CONTRACTOR POLISHED STAINLESS STEEL PINISH. � GRAFTER IIB- SECTION 603.5 40" MAX. CObipANY 4. ALL HOT, COLD AND WASTE LINES SHALL HAVE AN CONTRACTOR TO PROVIDE ALL BLOCKING AND 4INSULATION KIT INSTALLED. MIRROR LAVATORY 5111 X 180-2036 CONTRACTOR STANDARDS AS REQUIRED. _ S. MIRRORS SHALL BE MOUNTED NO HIGHER THAN 40'' SOAP AMERICANCONTRACTOR TO PROVIDE ALL BLOCKING ANDxkm ' AFF TO REFLECTIVE SURFACE. LAVATORY 05,71 CONTRACTOR DISPENSER SPECIALTIES STANDARDS AS REQUIRED. STRIKE o- 6. ACCESSORIES, WHEN MOUNTED BELOW GRAB BARS TOILET PAPER CONTRACTOR TO PROVIDE ALL BLOGIKING AND 4 SHALL HAVE 1 1/2" CLEAR FROM TOP OF LAVATORY 1501 K 8-686.7 SS CONTRACTOR16 ■■... ,7. ACCESSORIES SIDE DISPENSER STANDARDS A5 REQUIRED. ACCESSORY TO BOTTOM OF GRAB BAR. AMERICAN 299ONTRACTOR 8.010 CONTRACTOR TO PROVIDE ALL BLOCKIN6 AND _ ���� Q , BARS SHHALLALL WHEN INSTALLED ABOVE 6RRB TOILET LAVATORY HAVE A CLEARANCE OF 12" FROM STANDARD CADET ELONGATED CSTANDARDS A5 REQUIRED. THE TOP OF THE GRAB BAR TO THE BOTTOM OF: 42" GRAB BAR LAVATORY SOSRICK 5-6806-42-55 CONTRACTOR CONTRACTOR TO PROVIDE ALL BLOGKNG AND mdopw - ACC,!I RY, BUT NO HIGHER THAN 40" A.F.F. TO 1 STANDARDS A5 REQUIRED. NOT USED RESTROOM DOOR SIGN OPERABLE CONTROL CONTRACTOR TO PROVIDE ALL BLOCKING AND .. 36" GRAB BAR LAVATORY BOBRIGK $-6806-36-55 CONTRACTOR ( � E INTERNATIONAL INTERNATIONAL SYMBOL OF ACCESS STANDARDS AS REQUIRED. TODD SYMBOL FOR HEARING IMPAIRED 4 3 ABOVE MOP RHEEM REFER TO PLUMBING CONTRACTOR TO PROVIDE ALL BLOCKING AND R SCALE: N.T.S. SGA_ N.T.S. WATER HEATER SINK DRAWINGS STANDARDS STANDARDS AS REQUIRED. LETTERS AND NUMBERS: I. LETTERS AND NUMBERS ON 9I6NS SHALL BE RAISED 1/32" MINIMUMI 60" MIN. MUM 54" PREFERRED - WHERE ADJACENT OBSTRUCTION 48' MIN AND SHALL BE SANS-SERIF UPPERCASE CHARACTERS �� � ORW'4LLOCCURS DOOR TYPE: ACCOMPANIED 5� &RADE 2 BRAILLE. I " TIT 4' MAX. CLEAR WIDTH ANY AMOUNT 12"MINIMUM IP DOOR HAS p , MINIMUM 0"HbH SMOOTH SURFACE AT DOOR BOTTOM, 2. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" ¢. ,®, 1 i f BOTH A CLOSER AND A LATCH HIGH. EITHER ATTACHED PANEL OR BOTTOM RAIL. j f i � S. PICTORIAL SYMBOL 515NS (PICT06RAMS) SHALL Be ACCOMPANIED ,-t i j = 2 REQUIRED(,LEARSPAGE r � Z p BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY `� w' •• I K� p i HARDWARE: BELOW THE PICTOGRAM. THE BORDER DIMENSION OP THE = i 56" (MIND 61 BAR c 3 k' , w t- - - _ ._ i/ 2. KGPELE FNOALEPM ROM INSIDE WITHOUT USE OF KEY OR SPECIAL PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. °° w s 56 MINIMUM 417 1 / , EFFORT. ? 4. LETTERS AND NUMBERS ON SIGNS SHALL HAVE AWIDTH-TO-HEIGHT N 46 / O RATIO OF BETWEEN 3:5 AND I:I AND A STROKE WIDTH-TO-14151614T ,-,I - 4�" - E. OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE(NOT Z f 6RRB BAR REQUIRING GRASPING). o W RATIO BETWEEN I:5 AND 1:10. �1 \ \ V ac 5. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR FLR.SPACER FIG.(A) 1016.(5) �A HIGH FORWARD REACH LIMIT 4. MOUNTED 34" TO 44". BACKGROUND, EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACK6ROUND. '� z 5. MAXIMUM 5 L55.EFFORT TO OPERATE EXTERIOR DOOR, / � N \' .......- 46'MIN.AI FRONT GAPE HITS POST OR PYLON X 5 LBS.FOR INTERIOR. V 04 � u BEFORE PERSON HITS OBJECT q v ENTRY DOOR OR 60" MINIMUM ? Y C '9 m rn 6. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED AGGO¢DIN6 WHEN SIDE ENTRY DOOR ----� F 24'MIN.EXTERIOR- - J N c m TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE ` .� I 6"MIN. INTERIOR N 0p MINIMUM HEIGHT 15 MEASURED USING AN UPPER CASE X. _OWER _ l O O Q 6 CASE CHARACTERS ARE PERMITTED. FOR 516N5 SUSPENDED OR R U 411 ai+ 3 PROJECTED ABOVE THE FINISH FLOOR IN COMPLIANCE A-L aye } j REQUII�CLEAR SPACE a A m 33 SECTION 11215, THE MINIMUM CHARACTER HEISHT SHALL BE 3". U O T. CONTRACTED &RADE 2 BRAILLE SHALL BE USED WHEREVER ! - 4 / DOOR WIDTH PLUS c4 = N BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER GAPE RANGE 12" MAX CAPE RANGE Z Z 24' MIN.EXTERIOR J Z rn PORTIONS OF THESE REGULATIONS. DOTS SHALL BE 1/10" ON - I6" MIN.CLEAR, I6"MIN. INTERIOR CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS " PREFERRED FIG.W FIG. (B) qg" LAI PLAN © CORRIDOR PLAN �� M o SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKSROUND. PLAN �T�' 00 516N LOCATIONS: PROTRUDING OBJECTS 1. X SHALL 5E<25 INCHES;Z SHALL 5E>X. 51 MIN. EXTERIOR t 8" MINI" INTERIOR 36" TO 42" LEVER nI E + BEYOND STRIKE EDGE OFA OR U SHAPED rr ~ 8. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE (SATE OR DOOR ON THE 46" MINIMUM HANDLE •• 2. WHEN X< 20 INCHES,THEN Y SHALL BE 46 IP1GhES MAXIMUM. BY PERSONS WITH DISABILITIES AND AT EVERY MAJOR JUNCTION SIDE TOWARD WHICH IT ALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL SHALL --- COMPRES5ED CARPET 1/4" MAX. 3. WEEN X 15 20 TO 25 INCHES,THEN Y SHALL BE 44 INGPES MAXIMUM. SWIN65. - ,10'MIN.BOTTOM SE IDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL BELOW THRESHOLD FIN FLOOR LEVR RAIL OR PROVIDE IlesseO SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL - 2' MIN. �. KICK PLATE SI6N5, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG D © MAXIMUM FORWARD REACH OVER AN OBSTRUCTION U 1n APPROAGHIN6 PEDESTRIAN WAYS. PILE HEIGHT - a v, III h �18* MIN. , W 0 q. WHEN PERMANENT IDENTIFICATION 15 PROVIDED FOR ROOMS AND 2" CLENTERIOR p SPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE 24' MIN. ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH SECTION N _______ DaERIOR BUMPER ■ ■ d 111,76.5.6. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO TRANSITION BETWEEN FLOOR FINISHES OF BLDG. DETAIL RUBBERRU CHAIR Q = O THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDIN6 AT LEAF DOORS, 516N5 - SHALL BE PLACE ON THE NEAREST ADJACENT WALL, PREFERABLY J ON THE RI6HT. MOUNTING HEIGHT SHALL BE A MAX. 60" ABOVE THE FINISH FLOOR TO THE TOP OF THE 516N. MOUNTING LOCATION SHALL 2 „ WIDTH m BE DETERMINED 50 THAT THE PERSON MAY APPROACH WITHIN 5" O Z Z Q 1 -------J - 60" MIN. uuu =mm Z THE 516NA6E WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR O I f 1/2" MAX 50" st STANDING WITHIN THE SWING OF A DOOR. 1Fni'�_ (WHERE INDICATED) W CLEAR FLOOR SPACE NIGH AND LOW A NARROW FRAME WITH A BEVELED TOP EI 10. ADDITIONAL DIRECTIONAL 516N5 ALONG ACCE5516LE PATH OF �� (30 DEGREE MAXIMUM BEVEL TO VERTICAL PLANE) 6 MAX. B THRESHOLD 1/4' MAX' C PARALLEL APPROACH D SIDE REACH LIMITS � INSTALLED A7 THE BOTTOM OF A 6LA55 DOOR TRAVEL ARE REQUIRED. (WITH NO SIDE FRAMES) MAY IE USED IN LIEU 11. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY G MAX i OF FROVIDIN�THE REQUIRED O-INCH FACILITIES FOR PJBLIC USE SHALL HAVE INFORMATION POSTED IN I " MI UNINTERRUPTED SURFACE AT THE BOTTOM V'�S BLAIR S. f� THE LOBBY AS PART OF THE BUILDING DIRECTORY. 24" 50" © RAMP LANDING AT © VESTIBULE PLAN Of THE DOOR. LEACH INTERNATIONAL SYMBOL OF ACCESSIBILITY: / DOORWAY PLAN Q__ 12. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES. © ELEVATIONS LCI LEVEL` NOTES: 1/5/l5 13. WHITE PIOURE ON BLUE BACKGROUND, COLOR x 15040 ON FEDERA_ ® SCOTTSDALE,AZ STANDARD Is 595A. NOTE: 1. CLEAR SPACES MUST BE LEVEL TO PREVENT WHEELCHAIRS, rP� 60gq O'� NOTES: FROM ROLLING WHEN THE OCCUPANT RELEASES THE WHEEL 14. NEEM NS AND iC6 AGENCY DETERMINES, IF: APPROPRIATE, SPECIAL I. I/2"MAXIMUM TOTAL HEIGHT WITH I/4" MAXIMUM VERTICAL �TO� N DOOR. 1/4" PER FOOT 15 © DETAIL DESIGNS AND COLORS MRY BE APPROVED. I. TOILET PRIVACY UNISEX LOCK WF�1 IT IS A PRIVATE O O BRAILLE: CHANGE AT ED6E. i f - 15. USE CONTRASTED &RADE 2 BRAILLE. DOTS TO BE 0.1 INCH ON 2. GRAS 5'4,75%SEE TYPICAL AGGE55151LITY NOTES SHEET. 2. WHERE DOORS OPEN ONTO,BUT NOT INTO A CORRIDOR,THE EACH CENTER IN CELL. 2. : 2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE 15 OVER REQUIRED LEVEL AREA BEYOND THE DOORS MAY BE A MINIMUM OF DATE: SHEET: 16. 0.2 INCH SPACE BETWEEN CELLS. S. ALL ACCESSORIES WITHIN TOILET ROOM SHALL BE MOUNTED 1/4"VERTICAL LEVEL CHANGE. qg° 12/23/14 W/ THE OPERABLE PART AT NO HIGHER THAN 48" A.F.F. E❑ MAXIMUM SIDE REACH OVER AN OBSTRUCTION 3. 1/4"MAXIMUM VERTICAL LEVEL CHANGE. SCALE: IT. DOTS RAISED MINIMUM 0.025 INCH ABOVE 6,4CKGROUND. AS NOTED A 5 1 DRAWN BY: PROJECT No.: Has SIGNS / PICTOGRAMS PRIVACY / UNISEX TOILET ROOM THRESHOLD / LEVEL CHANGES REACH REQUIREMENTS DOOR CLEAR SPACE DOOR REQUIREMENTS 3201034418 • a ,S, e4 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall farm, arrangement and I composition of spaces, and elements of the design. Under such protection, unauthorized use of these x 2090. drawings and specifica}ions may result in cessation of METAL STUD DOOR eonstruefion, building seizure, and/or monetary liability. x 2090. HEADER METAL STUD DOOR I HEADER GG ESR 4943p REV -VII B ` FIRE TREATED IGG ESR 1663 (HILTI FA5TNER5) I FIRE TREATED WOOD SLOGKIN6. .. WOOD BLOCKING. MECHANICALLY I I 5/8" TYPE 'X' 6YP I I 9 HOLLOW METAL FASTENED I BD PER PLAN I DOOR FRAME AND JAMB 3-5/8" X 209a. SOLID WOOD FRAME METAL STUD DOOR, SEE SCHEDULE AND STOPPRAMIN6 AT 16"O.G. - - - - - - - I I n � DOOR, SEE I Q DOOR HEAD SCHEDULE BOTTOM TRACK w/ SCREW EACH DOOR HEAD I HILTI' DN OR DS STUD/JOIST, MIN. O SHOT PIN INTO SLAB I Cr 5/8" TYPE "X" 6YP. (2) 3-51 206A. AT 24" O.G. BD. BOTH SIDES 5/8" TYPE "X" 6YP. 6005162-33 (MIN. N OVER 3-5/8" METAL METAL STUDS. SO. BOTH SIDES BRIDGING BET STUDS. FIRE TREATED FIRE TREATED - - - - - - r- - OVER 3-5/8" METAL VERTICAL STUDS (2) WOOD BLOCKING. STUDS. BASE PER PLANS �8 ® EACH VERTICAL C WOOD BLOGKIN6. I (TO E BOTTOM) HOLLOW METAL a ANNDI STOP PRAM. *0 Q DOOR FRAME AND JAMB MECHANICALLY I IM DOOR, SEE - - - - - FASTENED to r" f 1 M SCHEDULE L 6 X 16 6A. TRACK I b SEE EXISTIN6 CONCRETE I ■- Q SLAB U1 le� DOOR JAMB DOOR JAMB = M Z H.M. DOOR JAMB/HEADER DETAIL TYP WOOD JAMB/HEAD DETAIL TYP INTERIOR PARTITION (BOTTOM) METAL STUD CONNECTION @WALL � O Q SCALE: I/2"=1'-O" • SCALE: 1 1/2"=I'-O" a SCALE: 1 I/2"=1'-O" SCALE: I/2"=1'-O" \ 4 LLO -� Z � NC 3 5/8" X 20 GAUGE O 3 5/8" X 20 6AUbE S DIA60NAL BRACING. ® \ / \ / RAGING. r ' 48" O.G. ® 45" \ / \ / y,8�� O.G. ® 45` --------- --- ------- alA60N L ALTERNATE 5'DE5. I c* M t ALTERNATE SIDES. \ \\ // // \\ \\ / SCREW BRAG I N6 TO SCREW BRAGINb TO \\ N / / \ \ / / STUD SECTION Al (2) STUD SECTION W/ (2) \ / x, E 1 X10 TEX 5GREW5 (TYP.) A V // // A V A / / O TEX SGRWS (TYP.) an 3-5/8" X 209a. METAL STUD \ V / \ \ / DIA60NAL BRACING a 48" O.G. \ x9-5/8 x2090. / b" L. x3-5/8 x209a. \ / STUD a a8" O.G. 1 IN ALTERNATE DIRECTIONS TO \ / \ \ "� STUD ® 48" O.G. '< > `<x� a SCREWED TO TOP STRUCTURE ABOVE. AS 1 x o SCREAM TO TOP REQUIRED TRACK A/ (2) # 10 TEK � � TRACK W/ (2) Is 10 TEK SCREWS. /� (3) X10 SCREWS AT 1 FIXTURE of/V/j SCREWS. DONT. 3-5/8" x - _ EACH CONN. I 209a. TOP OUTLINE 3-5/8" X 2090. METAL STUD SCAB TO TRACK P TOP OF PARTITION AT EACH BRACE A/ (2) X10 SCREWS EA TO TOP TRACK. PER PLAN _ - _ PER PLAN 5/6ONE 6YP. BD. 3-5/6" X 2090. CONT. _0iI I ONE SIDE OVER I I -- - TOP TRACK I SUSPENDED SUSPENDED 6YP. SD. 3-5/8" METAL J I N C E 1 815 1 SUSPENDED 6YP. BD. I I STUDS. GEILIN6, PER PLAN I ACOUSTICAL TILE I GEILIN6, PER PLAN 1 OCCURS, SEES I METAL STUDS 0 REFER TO iWALL I 01iPER PLAN i LE6ENDFER O A LL -METAL STUDS 0 16" . , ...-... -- -- METAL 90 PLAN EGEND FOR TYPE 5 L --------------- -- --- AT I b" O.G. ------- - ------------ -------- MAX. X 2090. METAL WALL SHEATHING, REPERR TO AALL #10 STUD FRAMING AT REFER TO WALL I SC TEK LE61I FOR TYPE I LEGEND FOR TYPE SCREWS I I W TYPE 'X' GYP 5D CONT. 18 6A. BOTTOM I I GOAT. 18 6A. BOTTOM OR PER PLAN. TRACK w/ 'HILTI' DN OR TRACK w/ 'HILTI' DN AI Ti D5 SHOT PIN INTO SLAB I 2 DS SHOT PIN INTO SLAB THIN BRICK VENEER ON 1/2" DUROCK z AT 24" O.G. ON b"x2090 METAL 5TUD5 AT 16" O.G. o AT 24" O.G. / / \ MAX. SCRIBE TO MALL GEILIN6 z ICG ESR 4443p REV 7/II 8 / � FLOORING E BASE IGG ESR 1663 (HILTI FASTENERS) FLOORING # BASE i I MATERIAL (SEE PLANS) MATERIAL (SEE PLANS) I I I I EXISTIN6 CONCRETE a >, `n v M H EXISTIN6 GONCRE ----- / SLAB ' 1 SLAB a ` m a a. m, .i e - V . d ��,e ° a. .° Q '9 Co rn A 0C J 07 t! I TYP. INT. PARTITION (TOP) INT. PARTITION W/ VOID SPACE ^„ TYP. NON-BEARING INT. PARTITION PLAN DETAIL AT FIXTURE Q �3 8 SCALE: I I/2"=1'-O' 7 SCALE: 1 I/2'=I'-O" V 5GALE: 1 1/2"=1'-O" 5 SCALE: 11/2"=I'-O" A LL 3 3 0 U) N C N J Z co VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS VERIFY THAT THE SHOWN METHOD NOS' Co ACCEPTABLE WITH THE ON-SITE COORDINATOR. IF NOT, OF ATTACHMENT IS ACCEPTABLE AT TOP TRACK DIRECTLY ATTACHED � ° M I K ro uNISrRUT (Ao _ CONTACT ARCHITECT FOR ALTERNATE DETAIL. WITH THE ON-SITE COORDINATOR. SLOTTED TRACK) W ._ IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. NOTE J LANDLORD NOTE REFER TO LANDLORD NOTE R TENANT'S STOREFRONT CONSTRUCTION MAY BE FLOOR SUPPORTED AT THE BASE ..... _.,, ,, -""' AT DETAIL 12/Ab I O AND SHALL BE LATERALLY BRACED AT THEIR HEAD SECTION TO LANDLORD'S I I STRUCTURAL PRAMIN6 OR SUPPLEMENTAL STEEL SECURED To THE STRUCTURAL 4x4 TUBE STEEL LINE OF EXISTIN6 MALL FRAMING. NO ATTACHMENTS TO THE LANDLORD'S MALL FINISHED BULKHEAD, O COLUMN GEILIN6 U GEILIN6 SYSTEM OR STEEL ROOF DECK SHALL BE PERMITTED. REFER TO LANDLORD NOTc` 5.4 AT SHEET SPS, UNISTRUT PI000 CLAMPED I I 1 ` W 4f 5YP To TOP CHORD OF JOIST 1/2' x 3/4 BLACK 0 EXISTIN6 METAL PAN DECK. W/ UNISTRUT BEAM CLAMP I METAL REVEAL IN MALL 5/S" TYPE 'X' IllO BRACING DETAIL FOR FLOOR SUPPORTED FRAMING ONLY! COLUMN BASE GEILIN6 PER MALL I I BD. ON a ><PI386. I CONNECTOR REQUIREMENTS. PATCH „•, �� - b x2090 METAL � A[ -- - - -- UNISTRUT PI000 CLAMPED USE UNISTRUT PI005, W/ I I AND REPAIR GEILIN6 TO STUDS AT 16" O.G. Q k' TO TOP CHORD OF JOIST EXISTIN6 METAL PAN DECK W/ UNISTRUT BEAM CLAMP - - --- - - - --- f WIDE BASE FLANGE, AT I THROUGH BOLT WITH �PI386. GONDITION5 WHERE SOFFIT WASHERS AND MATCH EXISTIN6 AFTER MAX. / 1 } - -------- CROSSES TRUSSES. j LOCKING NUTS O INSTALLATION __ _ ° 1 THIN BRICK VENEER ON I AIVE EASE -- - USE CONDITUNISTRIONS HERE W/ --- t--1-r--1 EL EXPANSION e CONCRETE m 6"x20 a METAL MAX. ---- -- -- - -- CONDITIONS WHERE SOFFIT I/2' MIN. FOR DEFLECTION. I 1/2" DUROCK ON ��, Q Q R GROSSES TRUSSES. AT # +----------+ SCRIBE O.C. MALL SAALL HEET A4.E SEE (2) 8 TEK SCREWS AT I I EA. CONNECTION. -- a - - GEILIN6 e i 2 # O 5GREW5 AT d EACH CONNECT ON. CONTINUOUS 20 6A. 4 MALL FLOOR FINISH TENANT FLOOR C a ° FINISH, SEE A2.1 C� /J ° <4 �' I - cv LEACH BLA1R S. 20 6A. DEEP LEb . e I' I 'p- .. - - . . _ o i TRACK ATTACHED CONT. 20 6A. SLOTTED I I .a ----i-i'---' a_4 TO DECK DEEP LES TRACK ATTACH TO METAL STRAPS. I I I EXISTIN6 JOIST. - ° - °° SCOTTSDALE,AZ #10 SELF TAPPING TEK 6034 �O't 5GREW5 ® Ib" O.G. I I I d°. - - 3 5/8" X 20 bA. METAL Q 3 5/8" X 20 6A. DIA6. EXISTIN6 JOIST. 6YP. BD. WHERE I I I STUDS a Ib" O.G. - - - F BRACING AT 48" O.G. TO OCCURS I STRUCTURE, TYP. REV ICC ESR 441 REV '7/11 4 I I I IGG ESR 4ei43p 7/II SHEET: ICC ESR 1663 (HILTI FASTENERS)` IGG ESR 1663 (HILTI FASTNERS) DATE' 12/23/14 SGLLE' AS NOTED TOP OF FULL HT INT. PARTITION *iqp� STEEL BASE CONNECTION TYP. BRICK VENEER PARTITION DRAWN BI: A612 DIAGONAL BRACING @ROOF SCALE: 1DECK o N.R. SCALE: I I/2'=1'-O' SCALE: I/2'= SCALE: I I/2"=1'-O" pROJEQNo.: 320103488 �sx