Plans (32)
V g INN INN DEC 21 2015 CITY r rOF Tr,AO MiTek° MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL14-412_UP_NEW Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45659553 thru R45659589 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. QED PR op L. ENGINE 87022PE ter` SAT OREGON rP <v/ 'AC ''.4 ER 1' `y0 OS A. H ER�� /' EXPIRES:06/30/ 7 October 15,2015 Hemandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. r • Job Truss Truss Type Qty Ply POLYGON R45659553 PL14-412_UP_NEW F01 Floor Girder 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:32:51 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-djkl9DkMr7FGHtlxDgngrLCFinXhFeKubsNKYdyTQng 1-0-0 1.15x3 II 1 3x4= 5 2 Scale=1:13.2 111•11-: o 0 N 1 r •-/f4 1 rd 4 ,/ 3 1.5x3 II 354= I 1-3-0 I 1-3-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL- in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.37 Vert(LL) 0.00 4 """ 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress lncr NO WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-3-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 4=183/0-3-8,3=219/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)277 lb down at 0-8-6 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert:3-4=-10,1-2=100 Concentrated Loads(Ib) Vert:5=-277(F) PR c�.�\ t3 N Fq s/p2 87022PE e v("" N y '31, OREGON 2? LU '90 �1BER '\.\ ,\ OS A- H0) .\ EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10103/2015 BEFORE USE. itiml » Design valid for use only with M7ek®connectors.This design is based only upon parameters shown,and is for an individual building component.not a truss system.Before use,the building designer must verify the appricabifity of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek* is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems.see ANSI/TPD Quality Cdteda,DSB-89 and SCSI BuBdng Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heibhts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659554 PL14-412_UP_NEW F02 FLOOR GIRDER 1 1 Job Reference(ootional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:53 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnayCd11-ZSsVaulcN IVzXBSKKFglxmldTa8QU FA2AsRcVyMne 0-1-8 .A 7� H I 1-0.0 1 f O .°I 1 1-2-0 1 r--11 1-2-0 1 p-11-131 Scale=1:41.4 4x6 II 3x6 FP= 3x6 FP= 1.5x3 =5x8 II 5x6 II 4x6 II 5x6 II 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 42AVM \WVflf\ Y1 I. /A Y ki lil OA./ `` ilil //ikV � � o e e1 - s l Je 'e ° , m e m e 1e ILSI d 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 5x6 II 6x8 II 6x8=3x6 FP= 5x6 II 5x6 II 3x6 FP=5x6 II 6x6= 6x6= 1.5x3 = 6x6-= 5x6 II 11-8-7 I 10-6i-7 }1-1"71 I 23-84 10-6-7 0-7-0 11-11-13 I 0-7-0 Plate Offsets MY)- 133:0-3-0,0-0-01,135:0-3-0,Edgel,141:0-1-8,0-0-81,[42:0-1-8,0.0.81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.16 Vert(LL) -0,19 34 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.38 Vert(TL) -0,30 34 >944 360 BCLL 0.0 Rep Stress Incr NO WB 0.29 Horz(TL) 0.06 26 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:208 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF No.1&Btr(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 41=1738/0.5-8,26=1460/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=2053/0,3-4=-2053/0,4-5=-3815/0,5-6=-3815/0,6-7=-5351/0,7-8=-5351/0, 8-9=-5351/0,9-10=-6071/0,10-11=-6071/0,11-12=-5955/0,12-13=5955/0, 13-14=-5690/0,14-15=-5690/0,15-16=-5173/0,16-17=5173/0,17-18=-4311/0, 18-19=-4311/0,19-20=-4311/0,20-21=-3119/0,21-220-3119/0,22-23=-1699/0, 23-24=-1699/0 BOT CHORD 40-41=0/1093,3940=0/2964,38-39=0/4611,37-38=0/4611,36-37=0/6017,35-36=0/6071, 3435=0/6071,33-34=0/5955,32-33=0/5955,31-32=0/5465,30.31=0/4823, 29-30=0/3745,28-29=0/3745,27-28=0/2439,26-27=0/907 WEBS 2-41=-2001/0,2-40=0/1849,4-40=1756/0,439=0/1640,11-34=-271/0,24-26=-1677/0, 24-27=0/1527,22-27=-1426/0,22-28=0/1309,20-28=-1207/0,6-39=-1535/0, 6-37=0/1425,9-37=-1354/0,9-36=0/257,20-30=0/1091,17-30=-986/0,17-31=0/674, 15-31=-563/0,15-32=0/434,13-32=-494/0 • NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x6 MT20 unless otherwise indicated. ��,0� PR OFFS 3)Refer to girder(s)for truss to truss connections. c5' 4)Bearing at joint(s)41 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity ��Cj NGI GINE-z- . , of bearing surface. . 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to Q� $7022 PE 91' be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. / 7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)1029 lb down at 7-6-0,and 177 lb down at 16-0-8 on top chord. The design/selection of such connection device(s)is the responsibility of others. J La N 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). 7 �"OT OREGO cid �f LOAD CASE(S) Standard ��Or, ER \' P�� 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) A HE� Vert:26-41=-8,1-25=-80 Concentrated Loads(Ib) Vert:9=-965(6)17=-177(6) EXPIRES:06/30/2017 October 15,2015 mannamw, -1E1, I . mil ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mirek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the appticobility of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage.delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quail*Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights-CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659555 PL14-412_UP_NEW F03 Floor Girder 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:53 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-Z5sVaulcNIVzXBSKKFglxmidcaCV QFA2AsRcVyTQne I 1-7-0 I I 1-9-0 Scale=1:17.8 6x6= 3x6 II 3x6 II 3x6 II 3x6 II 3x6 II 1 11 2 3 4 12 5 13 6 o d d N e e \_e Im 10 9 8 6x6= 5x6 II _ 3,6l1 6x6 I 9-4-0 0 I LOADING(psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.15 Vert(LL) -0.01 8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.11 Vert(TL) -0.02 8-9 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(TL) 0.00 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:78 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=1045/Mechanical,7=889/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-10=1033/0,1-11=-770/0,2-11=-770/0,2-3=-770/0,3-4=1123/0,4-12=-1123/0,5-12=-1123/0 BOT CHORD 8-9=0/1102,7-8=0/781 WEBS 5-7=-1068/0,5-8=0/476,4-8=-311/0,3-9=-463/0,2-9=-417/0,1-9=0/1082 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)276 lb down at 0-6-10,132 lb down at 2-1-13,132 lb down at 3-9-0,132 lb down at 5-4-3,and 132 lb down at 6-11-6,and 132 lb down at 8-6-9 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) P Vert:7-10=10,1-6=-100 ��ED OFFs Concentrated Loads(Ib) �'� GiNE .o, Vert:4=132(F)3=-132(F)2=132(F)11=-276(F)12=-132(F)13=-132(F) "� �N FR 0-44 9 87022PE r U' .. N -y �'o,,, OREG•N cy�O 9O 'M8ER �� Or, A. HERC-\P EXPIRES:06/30/2017 October 15,2015 Ngar I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MIF7473 rev.10/03/2015 BEFORE USE. Mill., Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verity the appricabirity of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek is always required for stabitty and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights.CA 95610 gr Job Truss Truss Type Qty Ply POLYGON R45659556 PL14-412_UP_NEW F04 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Wed Oct 14 15:32:54 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-1 HQtnEmF82dg8L1 WuzLXTzgnt_PPSgTKHgb_8yyTQnd 1-10-0 II 1-9-0 0-48Scale=1:41.4 4x6 II 3x6 FP= 3x6 FP= 1.5x3 = 5x6 ll 4x6 II 5x6 II 1.5x3 = 1 2 28 3 4 5 6 7 8 9 10 11 12 13 14 15 16 .\ \ // \ /tie\ \ / _a 27 te - e le.L - e z a 26 211 25 24 23 22 21 20 19 18 17 2x4 II 5x8= 44= 3x6 FP= 3x5= 3x5= 4x8= 3x4 = 1.5x4 SP= . I 23-11-12I 23-11-12 Plate Offsets(X,V)— 127:0-1-8,0-0-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.24 Vert(LL) -0.18 20-21 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.58 Vert(TL) -0.28 20-21 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.74 Horz(TL) 0.08 17 n/a n/a BCDL 5.0 Code IBC2012/1P12007 (Matrix) Weight:159 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 25=1061/Mechanical,17=1046/0-5-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-25=-1055/0,1-2=-1080/0,2-28=-1080/0,3-28=-1080/0,3-4=-2500/0,4-5=-2500/0, 5-6=2500/0,0.7=3276/0,7-8=-3276/0,8-9=-3416/0,9-10=-3416/0,10.11=2918/0, 11-12=-2918/0,12-13=-2918/0,13-14=-1785/0,14-15=-1785/0 BOT CHORD 23-24=0/1861,22-23=0/2951,21-22=0/2951,20-21=0/3406,19-20=0/3228,18-19=0/2417, 17-18=0/971 WEBS 15-17=-1373/0,15-18=0/1151,13-18=-894/0,13-19=0/709,10.19=-438/0,10-20=0/266, 6-21=0/461,6-23=-637/0,3-23=0/904,3-24=1104/0,1-24=0/1464 NOTES- 1)All plates are 3x6 MT20 unless otherwise indicated. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)20 lb down at 2-11-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. P 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ,\(-t��� OF�ss eco xJG I N . - �O LOAD CASE(S) Standard ' 2 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 ��' $70 2PE $' Uniform Loads(plf) Vert:17-25=-8,1-16=-80 Concentrated Loads(Ib) Vert:28=-20(B) N -, CV 7 '0), OREGO 2:' U <~ 'AO �'yBER '\1 r OS A. HER�P EXPIRES:06/30/2017 .116Sentd0. MEW=October 15,2015 ta.. WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIFl,,7173 re10/03/2015 BEFORE USE. Design valid for use only with M7ek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312 Alexandria,VA 22314. Suite 109 Citrus Heionts,CA 95610 V Job Truss Truss Type Qty Ply POLYGON R45859557 PL14-412 UP NEIN F05 FLOOR GIRDER 1 1 Job Reference(ootional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:55 2015 Page 1 ID c53KNt9S8dZANgLpvMEnZkyCdl1-V U_F?antuMmhmVciSgsmOBN_LOubBSKT1NULXhOyTQnc 1 1-2-12 1 1.5x3 11 1 3x4= 2 Scale=1:13.2 L 0 o N J 4 3 1.5x3 II 3x4= 1 1-5-12 1 1-5-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP 0 TCLL 40.0 Plates Increase 1.00 TC 0.07 Vert(LL) * 0.00 4 480 M12 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:12 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 1-5-12 oc puffins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF No.1&Btr(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=74/Mechanical,3=74/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ‹.,< � N-'� s�°7 `r 87022PE ,r -9C--- Cf) CNI /V y '02. OREGON rP <U ^PO FM8ER \\ O OS A. N ECk EXPIRES:06/30/2017 October 15,2015 A WARNING-Verify design parameters and REAL)NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Mt Design valid for use only with MiTekc9 connectors.Thu design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek. ek• is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPIl Quality Criteria,DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 xe Job Truss Truss Type Qty Ply POLYGON R45659558 PL14-412_UP_NEW F06 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:55 2015 Page 1 ID:c531 Nt9S8dZANgLpvMEnZRyCdll-VU_F?antuMmhmVciSgsmOBNyMOoZBLQTWULXhOyTQnc 0-1-8 Hi 2-1-12 1 2-6-0 I • Scale=1:35.5 1.5x3 II 1.5x3—1.5x3 = 3x5= 1.5x3 11 3x4= 1.5x3 11 • 3x4= 3x6 FP=1.5x3 11 3x5= 1.5x3 11 1 2 3 4 5 6 - 7 8 9 10 e e 18 gX Z 'INN 7 Ne 7 NO V 'INIIIIN. qq 4 17e e e 1 15 14 13 12 t 3x4= 3x6= 3x6 FP= 3x5= 3x6= 3x4 = I 20412 20-4-12 LOADING(psf) I SPACING- 1-7-3 CSI. DEFL- in (loc) I/deft Ud PLATES GRIP TOLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.12 13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.39 Vert(TL) -0.20 13-15 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.51 Horz(TL) 0.05 11 n/a n/a BCDL 5.0 Code IBC2012/fP12007 (Matrix) Weight 101 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=886/0-2-12,16=886/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1750/0,34=-1750/0,4-5=-2406/0,5-6=-2406/0,6-7=1835/0,7-8=-1835/0,8-9=1835/0 BOT CHORD 1516=0/945,14-15=0/2219,13-14=0/2219,12-13=0/2262,11-12=0/1076 WEBS 9-11=-1334/0,9-12=0/940,6-12=-529/0,4-15=-581/0,2-15=0/998,2-16=1240/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)CAUTION,Do not erect truss backwards. �< cO PROP �‹� GNGI N4-,9 wo -0,-Zkr9 870 2PE � OcOOBR.EEGRO �� Q�� ';) c'O1 `1AHE' EXPIRES:06/30/2017 . �..�_ .. ..�..T: ,,._ .._. October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not - a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate tillsdesign into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' a always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 V • Job Truss Truss Type Qty Ply POLYGON R45659559 PL14-412_UP_NEW F07 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:32:56 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-zgYeCwoViguYOfBvOON?YOw98oErwv4dk745DgyTQnb a1H8 Scale=1:39.4 3x6 FP= 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16 17 18 19 20 e9 e g- 8 8 a 0 0 0 g 0 0 m a a 0 e g a TI 42 0 o d d N N a e i i o- R a e 5 I 7q F q A e i o P 41 Nr 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 3x6 FP= r ..r._r - s .�.tr .l-.r 'ter 1r_r 1 .i 1,1 ,noy_. .rr 4. ::s .rI 1 . r _-,a _ 1 - 1-4-0 1-4-0 14-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-3-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.07 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 21 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:112 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY BRACED AGAINST LATERAL MOVEMENT(I.E. DIAGONAL WEB). REACTIONS. All bearings 23-11-12. (Ib)- Max Gray All reactions 250 lb or less at joint(s)40,21,39,38,37,36,34,33,32,31,30,29,28,27,26, 25,24,23,22 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. (.........i_.-0 P oFF<5'sGss NFi oR 9 87022PE . r" tP �y '0j, OREGON � �MO8ER EXPIRES:06/30/2017 October 15,2015 c Mi0 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with M7ek�connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall 'f building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage.delivery,erection and bracing of trusses and truss systems.see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Betiding Component Solely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss TypeQty Ply POLYGON PL14-412_UP_NEW FOB FLOOR GIRDER R45659560 1 1 Pacific Lumber&Truss Co., Beaverton,Oregon Job Reference(optional) 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:57 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11Ss50QGo7Qz0P?o15Z5uE5cSKK3BaMfJ4mzngeiHyTQna I 2-0-0 I O16-12 11-2-12 1pYf{8 Scale.=1:42.9 356= 3x4 II 3x4= 3x4= 3x4= 3x4= 3x6 FP=3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15a 11. 26d / /♦ / / dH a • i'�....... a 25♦ ♦ ♦ • ♦ ♦ ♦♦ • • 24 23 22 21 20 19 18 17 16 3x6= 3x5= 3x6 FP= 3x5= 3x5= 3x5= 3x5= 4x6= 3x4= I 23-6-12 25-2-0 23-6-12 2 -8 0- 1-5-12 i Plate Offsets(X,Y)— (1:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.12 Vert(LL) 0.00 18 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.05 Vert(TL) -0.02 23-24 >999 360 BCLL 0.0 Rep Stress!nor NO WB 0.24 Horz(TL) 0.00 18 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:138 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except BOT CHORD 2x4 DF 2400E 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 23-8-4. (Ib)- Max Uplift All uplift 100 lb or less at joint(s)18 Max Gray All reactions 250 lb or less at joint(s)24 except 17=768(LC 1),17=768(LC 1),23=392(LC 3), 21=364(LC 3),20=363(LC 3),19=361(LC 3),18=296(LC 3) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 16-25=-377/0,25-26=377/0,15-26=-377/0,13-14=0/286 BOT CHORD 16-17=-286/0 WEBS 14-17=-579/0,14-16=0/474 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)272 lb down at 24-11-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ����� P R OFFS LOAD CASE(S) Standard s 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 ,N.7 ��G(N��R /O2 Uniform Loads(pit) Vert:16-24=-8,1-14=-80,14-15=-180(F=-100) $70 2PE 9f Concentrated Loads(Ib) Vert:15=-272(F) N -7,‘SAT GREG N ti� �N '0 �'y$ER �N �O OS A- HEY' EXPIRES:06/30/2017 October 15,2015 Immo ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev,10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/7P11 Qualify Criteria,DSII-89 and ICSI Building Component 7777 Greenback Lane Safety Informaifon available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 • Job Truss Truss TypeQty Ply POLYGON R45659561 PL14-412_UP_NEW F09 GABLE 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:58 2015 Page 1 ID:c53KNt9S8dZANgLpvM EnicyCd11-w3f0dcpIBHBGdyKH7oPTep?WvbwKOpZwCRZBHjyTQnZ Scale=1:14.0 1 2 3 4 5 6 7 e e eIII ill II 16 0 o n 0 15 ; 111 1 1 I ill II • • 14 13 12 11 10 9 B 40-0 5-4-0 6-8-0 j '7-4-0 1 1-4-0 2-8-0 1 1-4-0 + 1-4-0 I 1-4-0 0-8-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL- in (lac) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 8 n/a n/a Weight:38 lb FT=0%F,0%E BCDL 5.0 Code IBC2012/TPI2007 (Matrix) LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY BRACED AGAINST LATERAL MOVEMENT(I.E. DIAGONAL WEB). REACTIONS. All bearings 7-4-0. (Ib)- Max Gray All reactions 250 lb or less at joint(s)14,8,13,12,11,10,9 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. < GNES/ 87022PE 9c y 'o). OREG•NcidO� �C'OFMBEFt >> P� S A. HERS EXPIRES:06/30/2017 October 15,2015 4 4 � AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIE7473 rev.10/03/2016 BEFORE USE. lill. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and'a for an individual building coponent,not a inns system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ��� „ building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery.erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights.CA 95510 V Job Truss Truss Type Qty Ply POLYGON R45659562 PL14-412_UP_NEW F10 GABLE 1 1 Job Reference(ootional) Pacific Lumber&Thins Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:32:58 2015 Page 1 I D:c53KNt9S8dZAN gLpyM EnZkyCd I1-w3fOdcpl B HBGdyKH 7oPTep?WubwJ OpYwC RZB HjyTQ nZ Opii 1 2 3 4 5 6 Scale=1:12.8 L _ e e 14 : o N e r e s e 13 12 11 10 9 8 7 1-4-0 I 2-8-0 I 4-0-0 I 1-4-0 1-4-0 1-4-0 1-4-0 I 6-2-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:33 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY REACTIONS. All bearings 6-2-12. BRACED AGAINST LATERAL MOVEMENT(I.E. DIAGONAL WEB). (Ib)- Max Gray All reactions 250 lb or less at joint(s)12,7,11,10,9,8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. '\�Q,EO PRO�Fss 5 ,$INF6, /a 87022PE 9r' / N - �Aj, OREGO do �� �O ''41 ER \�` N© �`) A. HEek EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIF7473 rev 10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use.the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' ek^ is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI(TP11 Qua*Criteria,DSS-89 and SCSI Sending Component 7777 Greenback Lane Safety Information available from Tom Plate Institute,218 N.Lee Street,Suite 312 Alexandna,VA 22314. Suite 109 Citrus Heghis,CA 95610 V Job Truss Truss Type Qty Ply POLYGON R45659563 PL14-412_UP_NEW F11 Floor 8 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:32:59 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-0FDmrygNyaG7F6vUhWwiA1 Xfm?A37873R5JIg9yTQnY 0-1-8 HI 1-8-12 1 1 1-6-8 1 2-0-0 1 Scale=1:38.0 354= 3x4 = 3x4 I I 4x4= 3x4= 3x4= 3x6 FP= 3x5-=- 1 1 2 3 4 5 6 7 8 9 10 11 12 13 2 g o d d N a `e m lir- w�. c ° � g pZ° 21 20 19 18 17 16 15 14 3x6= 3x6 FP= 3x5= 3x5= 3x6= 3x4= 4x6= 1 1-11-12 2-11.4 22-4-12 I 1-11-12 0-1-a 20-3-8 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.12 16-17 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.42 Vert(TL) -0.19 16-17 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.52 Horz(TL) 0.05 14 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except 6-0-0 oc bracing:18-20. REACTIONS. (lb/size) 14=856/0-2-12,20=1364/0-5-8 Max Gray 14=880(LC 4),20=1364(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=0/346,2-3=0/345,3-4=-1381/0,4-5=1381/0,5-6=-2237/0,6-7=-2237/0,7-8=2294/0,8-9=-2294/0, 9-10=-2294/0,10-11=-1556/0,11-12=-1556/0 BOT CHORD 19-20=-138/646,18-19=-138/646,17-18=0/1900,16-17=0/2357,15-16=0/2017,14-15=0/881 WEBS 1-20=-484/0,12-14=-1191/0,12-15=0/912,10-15=-623/0,10-16=0/374,5-17=0/492,5-18=-737/0,3-18=0/1034, 3-20=-1116/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)14. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)272 lb down at 0-2-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). <<-,c,,c) P R OFFS LOAD CASE(S) Standard �S ENGINEER wo 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 (V -9 Uniform Loads(plf) 4 . 870 2P E f Vert:14-21=8,1-13=-80 Concentrated Loads(lb) Vert:1=-272(F) . .y SAT OREG N (y5/ 9OM8ER *\\ On A, HE.0 EXPIRES:06/30/2017 October 15,2015 Mila ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE A81-7473 rev.10/03/2015 BEFORE USE • Design valid for use only with MiTek®connectors.The design k based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated B to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems.see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Suite 109 Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heiohts,CA 95610 V Job Truss Truss Type Qty Ply POLYGON R45659564 PL14-412_UP_NEW F12 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:00 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl l-sRn821rOjuO_sGUgFDSxjE4sTPYOshRCfl2IMbyTQnX 0-1-8 HI 1-2-12 1 I}8-41 2-0-0 I Scale=1:43.4 1.5x3 = 3x6 FP= 3x6 FP= 1.5x3 = 4x6 II 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 HJ w e H HJ U . t� / L o a\I/2i / X... / N. / \ / / \ 926 4 e e 25 24 23 22 21 20 19 18 17 1.5x3 I I 4x6= 3x6 FP= 3x5= 3x5= 3x5= 3x5= 3y4 = 1 1-5-12 1-T1-4 25-2-0 1-5-12 0-4-8 23-6-12 Plate Offsets(X,Y)— f1:0-1-8,0-0-81 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TOLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) -0.09 20 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 022 Vert(TL) -0.15 19-20 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.14 Horz(TL) 0.04 17 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:167 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF No.1&Btr(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:24-25,23-24. REACTIONS. (lb/size) 17=622/Mechanical,24=2401/0-5-8 Max Gray 17=640(LC 4),24=2401(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-2=0/297,2-3=0/293,3-4=-839/24,4-5=-839/24,5-6=-1707/0,6-7=-1707/0, 7-8=1707/0,8-9=-2057/0,9-10=-2057/0,10-11=-1891/0,11-12=-1891/0, 12-13=-1891/0,13-14=-1210/0,14-15=-1210/0 BOT CHORD 22-23=0/1327,21-22=0/1327,20-21=0/1933,19-20=0/2024,18-19=0/1603,17-18=0/668 WEBS 2-24=1393/0,1-24=465/0,15-17=-890/0,15-18=0/720,13-18=-524/0,13-19=0/382, 8-21=-329/0,5-21=0/530,5-23=-678/0,3-23=0/857,3-24=-709/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x6 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)272 lb down at 0-1-8,and 1230 lb �(� �d PROF tss down at 1-8-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. F 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). �,CO NGI NE -, /o LOAD CASE(S) Standard Q� $7(}22 P/ 29r— 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert:17-25=-5,1-2=-150(F=-100),2-16=-50 Concentrated Loads(Ib) 7 • CV Vert:1=-272(F)2=-1230(F) Nt SAT OR GON qo O1U -V 1.0?, 4/ EB -\\�Q' et 1.3 A. HEY, EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev,10/03/2015 BEFORE USE, Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verity the appricabilty of design parameters and properly incorporate this designminto the overall a building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek- is always required for stability and to prevent collapse with possible personal injury and property damage.for general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Ckrus Heiohts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659565 PL14-412_UP_NEW F13 Floor 5 1 Job Reference(optional) Pacific Lumber Si Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:33:00 2015 Page 1 I D:c53KNt9S8dZANgLpvMEnZkyCdl l-sRn821rnoj�u�O_sGUgFDSxjE4g4PZisiPCf121MbyTQnX _... 0-64 4xi-1 1-2-0 I I 48-7 4x4--I 1-2-0 1 1 0-6-1 1 l---f 1 2 3 4 5 4x4 = 8 Scale=1:12.9 13 N • 4x4= • 12 11 10 9 8 - 4x4= 4x4= I 2-10-11 1 3-5-11 1 4-0-11 1 4-11-4 I 2-10-11 0-7-0 0-7-0 0-10-9 Plate Offsets(X,Y)— 12:0-1-8,Edgel,14:0-1-8,Edgel,f5:0-1-8,Edae1,f7:Edae,0-1-81,f10:0-1-8,Edael,f12:Edae,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.13 Vert(LL) -0.02 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.14 Vert(TL) -0.03 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:37 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=209/Mechanical,7=204/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. WEBS 2-12=314/0,5-7=-306/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Bearing at joint(s)7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 31 nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. ��1rEO PROFESS tc5 Nsv,INEFR /o29 870 2PE 7 NEAT OREGO /�Q<v�' 9O 4/ ,<Z) 0/1 �s A. HEc.);t4P EXPIRES:06/30/2017 October 15,2015 AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE 911-7473 rev.10/03/2015 BEFORE USE. . Design valid for use only with M7ek®connectors.This design is based only upon parameters shown,and is for an individual building component,not trussa system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,051.89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. CiWs Heights.CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45659566 PL14412_UP_NEW F15 FLOOR 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:01 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-KeLW FeseUC WrUQ3soxzAFSdzzptBb6HMuPosu2yTOnW I 0-6-4 I I 1-2-0 I I o-8-7 I I 1-2-0 I I 1-5-1 I 2-6-0 Scale=1:16.4 1.5x3 II 4x4= 1.5x3 I I 1.5x3 I I 3x4= 1.5x3 II . 1 2 3 4x4= 4 5 6 7 -j//: \ _.\\ b e e o e 3x4= 13 12 11 10 9 8 1.5x3 II 1.5x3 II 4x4= 4x4= 3x4= I 2-10-11 1 3-5-11 14-0.11 I 8-2-12 I 2-10-11 0-7-0 0-7-0 4-2-1 Plate Offsets(X,Y)— 12:0-1-8,Edoel.13:0-1-8,Edgel,f9:0-1-8,Edgel,f10:0-1-8,Edgel.f13:Edae,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.32 Vert(LL) -0.03 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.32 Vert(TL) -0.06 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 023 Horz(TL) 0.00 8 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:49 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=356/Mechanical,8=356/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=-380/0,4-5=380/0,5-6=-380/0 BOT CHORD 9-10=0/380,8-9=0/353 WEBS 4-10=-262/0,2-13=-620/0,3-10=0/446,6-8=-437/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��'Ea PRO c5 ,NGiNEFR X02 t. . 870 2PE /9r to 9 <‘-‘ ,.. ty '0)., OREGON l- </ 9O AMBER �1 �O � S A. 1-10; EXPIRES:06/30/2017 October 15,2015 mii ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEI(REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and Is for an individual building coponent,not . a truss system.Before use,the building designer must verily the applicability of design parameters and properly incorporate the design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing !Miiek" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safely InformatIon available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiohts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659567 PL14-412_UP_NEW F16 FLOOR 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:02 2015 Page 1 I D:c53KNt9S8dZANgLpvMEnZkyCdl l-ogwTz5GFVei6ae2MeUPof997C9fKSUV73XPQUyTQnV 0-1-8 LI 1 1-2-12 I p-8-41 2-0-0 i Scale=1:42.8 4x5= 3x4 = 3x4 II 3x4= 3x4= 3x4= 3x6 FP=3x4 = 4x4= 2 3 4 5 6 7 8 9 10 11 12 13 14 15 aA e tA e d a� / \ w 2 er e � e e - . 24 23 22 21 20 19 18 17 16 4x6= 4x6= 3x6 FP= 3x5= 3x5= 3x5= 4x6= 3x4= I 1-5-12 1-71.4 25-2-0 I 1-5-12 0.1-8 23-6-12 LOADING(psi) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.23 Vert(LL) -0.21 19 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.56 Vert(TL) -0.33 18-19 >867 360 BCLL 0.0 Rep Stress Incr NO WB 0.68 Horz(TL) 0.07 16 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:136 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:22-23. REACTIONS. (Ib/size) 16=1013/Mechanical,23=1450/0-5-8 Max Gray 16=1028(LC 4),23=1450(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 34=1350/0,4-5=-1350/0,5-6=-2679/0,6-7=-2679/0,7-8=-3209/0,8-9=-3209/0,9-10=-2943/0,10-11=-2943/0, 11-12=-2943/0,12-13=-1881/0,13-14=1881/0 BOT CHORD 22-23=-123/379,21-22=0/2105,20-21=0/2105,19-20=0/3036,18-19=0/3168,17-18=0/2504,16-17=0/1043 WEBS 14-16=-1410/0,14-17=0/1132,12-17=-842/0,12-18=0/593,9-18=-304/0,7-19=0/256,7-20=-504/0,5-20=0/797, 5-22=-1042/0,1-23=-399/0,3-22=0/1335,3-23=-1100/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)272 lb down at 0-2-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ���c0} PR Or�ss LOAD CASE(S) Standard ���Gj tiNGINE -, /0� 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 UniiformLoads(plf) 87022PE �v" Vert:16-24=-8,1-15=-80 Concentrated Loads(Ib) Vert:1=272(F) CD cV y �Al, OREG•N ci;:)OL �0 FMgER 'N\` EXPIRES: 06/30/2017 October 15,2015 CAMMANSNEVM JEW 13i or. ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly incorporate the design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stabilty and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,emotion and bracing of trusses and truss systems,see ANSI/TPt1 Quality Criteria,DSB-89 and SCSI Building Component 7 109 Solely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659568 PL14-412_UP_NEW F17 Floor 16 1 Job Reference(ootional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:02 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdI1 ogwTzsGFVei6ae2MeUPof99iC9vKRDV73XPQUyTQnV iii7-41 2-6-0 0-1T8 Scale=1:40.7 4x6= 3x4= 3x4= 3x4= 3x6 FP= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 N o - N 0 21 / NN 47 -NSN 7 NN - 7 2 -1 7 IF - 20 19 18 17 16 15 14 13 4x4 = 4x8= 3x6 FP= 3x5= 3x5= 4x6= 3x4= 00--1-8 23-11-12 23-10-4 I Plate Offsets Mr- (19:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) Udefl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.22 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.54 Vert(TL) -0.36 15-16 >783 360 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1043/0-5-4,19=1043/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1581/0,34=1581/0,4-5=-3040/0,5-6=-3040/0,6-7=-3266/0,7-8=3266/0,8-9=-2265/0,9-10=-2265/0, 10-11=-2265/0 BOT CHORD 18-19=0/377,17-18=0/2450,16-17=0/2450,15-16=0/3294,14-15=0/2907,13-14=0/1291 WEBS 11-13=-1600/0,11-14=0/1207,8-14=-796/0,8-15=0/444,6-16=-314/0,4-16=0/731,4-18=-1077/0,2-18=0/1492, 2-19=1125/0 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ���E D PR 0pe �,5 oAGINEF,9 /% 2 `C" 87022PE -�r- / N - �•Cj, OREGO rya �c 'AO FM$ER �q �4 On A- HEC; EXPIRES:06/30/2017 October 15,2015 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated u to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,emotion and bracing of trusses and truss systems,see ANSI/TPl1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus FleMhts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659569 PL14-412_UP_NEW F18 FLOOR 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon - 7.530 s Jul 11 2014 MTek Industries,Inc.Wed Oct 14 15:33:03 2015 Page 1 1 D:c53KNt9S8dZANgLpvMEnZkyCd11-GOTHgJtuOpmZkjD FwM?eLtiKZcVK3uKfLjHyzwyTQnU 0-1-8 19 N 2-6-0 Scale=1:40.1 6x6= 3x4 = 3x4= 3x4=3x6 FP= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 2i jirqpr,. ..,• irv-,.. gp„-Nipy IN... <''S N iii l' 19 18 17 16 15 14 13 6x8 = 4x8= 3x6 FP= 3x5= 3x5= 4x6= 3x4= 23-8-0 I I 23-8-0 Plate Offsets 0(Y)- f19:Edge,0-1-81.119:0-1-8,0-0-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.21 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.53 Vert(TL) -0.35 15-16 >803 360 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(TL) 0.07 13 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 OF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1032/Mechanical,19=1027/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1461/0,3-4=-1461/0,45=-2950/0,5-6=-2950/0,6-7=-3206/0,7-8=3206/0,8-9=-2235/0,9-10=-2235/0, 10-11=-2235/0 BOT CHORD 17-18=0/2345,16-17=0/2345,15-16=0/3219,1415=0/2862,13-14=0/1276 WEBS 11-13=-1581/0,11-14=0/1188,8-14=777/0,8-15=0/426,6-16=-333/0,416=0/750,418=1095/0,2-18=0/1511, 2-19=-1125/0 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Refer to girder(s)for truss to truss connections. 3)Bearing at joint(s)19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect buss backwards. Co c N Fg s�°2 87022PE �r ySATOREG•N c- O�UV pS A. Nev.` EXPIRES:06/30/2017 October 15,2015 ..r ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M/F7473 rev.10/03/2015 BEFORE USE. " Design valid for use only with MitekE connectors.This design is based onlyupon parameters shown,and is for an individual building component.not a truss system.Before use,the building designer must verify the applicability ty of design parameters and property incorporate tills design into the overall '���,. building design:Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/lPl1 Quality Criteria,DSB-89 and SCSI Building Component Suite 109 Solely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659570 PL14-412_UP_NEW F19 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:04 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-kDOfutuWn7uQLtoRU3Wtt4FXL0xIoT oaNOVWNyTQnT 0-1-8 HI 1-8-12 1 1 2-2-0 1 2-6-0 I Scale=1:38.5 1.5x3 = 3x6 FP= 3x6 FP= 1.5x3 = 5x6 II 4x6 II 1 2 3 4 5 6 7 8 9 10 11 12 Fii 407411.11%,,4444N,,1 11�17 20 i„...,. A. FIR 19 18 17 16 15 14 13 1.5x3 II 3x6 FP= 3x8= 3x5= 3x4 = 1 1-11-12 2-174 22-4-12 1-11-12 0-1-8 20-3-8 1 Plate Offsets(X,Y)— 11:0-1-8,0-0-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.12 Vert(LL) -0.05 15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.13 Vert(TL) -0.09 15-16 >999 360 BCLL 0.0 Rep Stress Incr NO WB 023 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:143 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400E 2.0E(flat) end verticals. WEBS 2x4 DF No.1&Btr(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 13=811/0-5-8,18=3148/0-5-8 Max Horz 13=1594(LC 4),18=1594(LC 4) Max Gray 13=868(LC 4),18=3148(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=0/829,2-3=0/828,3-4=-1649/154,4-5=-1649/154,5-6=-1649/154,6-7=-2380/0, 7-8=-2380/0,8-9=-1842/0,9-10=1842/0,10-11=1842/0 BOT CHORD 17-18=-1035/0,16-17=-1035/0,15-16=0/575,1415=0/749,13-14=-501/163 WEBS 2-18=-1533/0,1-18=-1113/0,11-13=-1338/0,11-14=0/917,8-14=-519/1,6-15=0/360, 6-16=-731/0,3-16=0/1140,3-18=1355/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x6 MT20 unless otherwise indicated. 3)Non Standard bearing condition. Review required. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)608 lb down at 0-1-8,and 1200 lb �� �D PROF c5' down at 2-3-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. Q� 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). Co ANG I N EER s/O LOAD CASE(S) Standard s,zt, -7 1----- 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 87022P; Uniform Loads(plf) Vert:13-19=-8,1-2=-180(F=100),2-12=-80 Concentrated Loads(Ib) CV Vert:1=-608(F)2=-1200(F) - . , N 7 '0j, OR GON ti� 150 �o AMBER >> �Q 011 A. HE. EXPIRES:06/30/2017 October 15,2015 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE _- 1 Design valid for use only with Milek©connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiWek' B always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSS-89 and SCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659571 PL14-412_UP_NEW F20 Floor Supported Gable 1 1 Job Reference(ootionall Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Wed Oct 14 15:33:04 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-kDOhituVVn7uQLtoRU3Wtt4FYNO4oW1 oaNOWUNyTQnT Scale=1:18.7 1 2 3 4 5 6 7 8 9 10 0 O 0 O 0 O o O O O O o d d N y -,Lo & .e 9 O tr 4 20 19 18 17 16 15 14 13 12 11 11-4-8 I I 11-4-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:55 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY BRACED AGAINST LATERAL MOVEMENT(I.E. DIAGONAL WEB). REACTIONS. All bearings 11-4-8. (Ib)- Max Gray All reactions 250 lb or less at joint(s)20,11,19,18,17,16,15,14,13,12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. PR Ore, c.;• •Y AD N F'4 s/0 ' 870 2PE y �4>, OREGO 2 Q.UU �C $'44 `V -1 Nt �S A. HE3k EXPIRES:06/30/2017 October 15,2015 minmes r ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 ree.10/03/2015 BEFORE USE. Ell Design valid for use only with MTeke connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI)Qualify Criteria,008.89 and BCSI Building Component 7777 109 Solely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Cibus Heiohts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659572 PL14-412_UP_NEW F21 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 S Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:05 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-DPa15?v8Y000z1Ndln16QInhCQJBXz6yp1m31pyTQnS 1.5x3 11 0-7-12 2-6-0 1.5x3 II 1 2 4x4= 3 Scale=1:13.0 J L- 5 4 4x4= 3x4= 0-1-6 3-4-12 3-3-4 Plate Offsets(X,Y)— f5:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 •'•' 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.06 Vert(TL) -0.02 4-5 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.04 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:21 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-4-12 oc puriins, except BOT CHORD_2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 4=144/0-1-8,5=144/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)4,5. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ° P R ok-R, EFR /f w 2.9 870 2PE cti -NEAT OREGO ti OWN "b SER OSA. HECk- EXPIRES:06/30/2017 October 15,2015 Nomesemon AA WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component.not truss a system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual tens web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Cdteda,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659573 PL14-412_UP_NEW F22 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:05 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdll-DPa15?v8YQ0Gz1Ndln16QInh7QGIXuOyplm3lpyTQnS 1 1-3-12 1 26-0 I Scale=1:24.9 1.5x3 II 3x4 = 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 I I 1 2 3 4 5 6 7 imm b b N 8 R A. Nir 1♦ 10 9 if 3x4= 3x5 = 3x5= 3x4= 0-1 14-3-12 I 0- 14-2-4 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (roc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.24 Vert(TL) -0.08 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.35 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=624/0-2-8,11=624/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-977/0,3-4=-977/0,4-5=-1120/0,5-6=-1120/0 BOT CHORD 10-11=0/427,9-10=0/1189,8-9=0/719 WEBS 6-8=-891/0,6-9=0/497,4-10=-264/0,2-10=0/682,2-11=-721/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. PR 0 Fes c-5 ��GIN ''6) s)029, 87022PE . l" N „, y ,, OREGON rim Q�N 900��8ER �1• 7- S A. H ECk EXPIRES:06/3012017 October 15,2015 e r mil..... ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mf iek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/T111 Quallly Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiohts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659574 PL14-412_UP_NEW F23 Floor 7 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 5 Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:06 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-hb8PJLvmJk87bBxgbUYLyVKrWgZYGIn52hVdzFyTQnR I—II 2-6-0 I 0-11.18 Scale=1:36.8 4x4 = 3x4= 3x4= 3x4= 3x6 FP= 3x5= 1 2 3 4 5 6 7 8 9 10 11 ' o - d m m t a 20 I \ 7 .N. 7 NN 7 7' N II 19 18 17 16 15 14 13 12 4x5= 3x6 FP=3x6= 3x5= 3x8= 3x4= I 21-6-12 21-6-12 Plate Offsets(X,Y)— 11:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.15 14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.43 Vert(TL) -0.25 14-15 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.06 12 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:110 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 18=937/0-2-12,12=937/0-5-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-18=-949/0,1-2=-414/0,2-3=-414/0,3-4=-2170/0,4-5=2170/0,5-6=-2686/0,6-7=-2686/0,7-8=-1975/0, 8-9=-1975/0,9-10=-1975/0 BOT CHORD 16-17=0/1437,15-16=0/1437,14-15=0/2569,13-14=0/2472,12-13=0/1146 WEBS 10-12=-1420/0,10-13=0/1027,7-13=-616/0,7-14=0/264,5-15=-495/0,3-15=0/908,3-17=-1267/0,1-17=0/1042 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)18. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. On ��\� tc... F4'GINE ' ice 870 2PE 9c- N N y �Aj, OREG N ti� 4N 1, OBER 1'` �p On A. HEY` EXPIRES:06/30/2017 October 15,2015 a almN WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mick®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' a always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualtly Criteria,DSI-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45659575 PL14412 UP NEW F24 GABLE 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:06 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdll-hb8PJLvmJk87bBxgbUYLyVKuugfCGQY52hVdZFyTQnR 0-1H8 Scale=1:33.5 3x6 FP= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ea a a O 0 e 0 _0 a _� •0 0 0 38 d d i N N W 37 e a e o a o o a e e a o a o d e a 0r 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 3x6 FP= 1 1-4-0 1 2-8-0 1 4-0-0 1 5-4-0 1 6-8-0 1 8-0-0 1 9-4-0 l 10-8-0 1 12-0-0 i 13-4-0 l 14-8-0 1 16-0-0 1 17-4-0 1 18-8-0 1 20-0-0 29--4-12 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 04-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL- in (loc) l/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 19 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:97 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY BRACED AGAINST LATERAL MOVEMENT(I.E. DIAGONAL WEB). REACTIONS. All bearings 20-4-12. (lb)- Max Uplift All uplift 100 lb or less at joint(s)19 Max Gray All reactions 250 lb or less at joint(s)36,19,35,34,33,32,31,30,29,28,27,26,25,23,22, 21,20 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. 2 J2 \yc" -y �'o), OREG N ti�©<U ^PC'OM8 ER \�' S A. HECk EXPIRES:06130/2017 October 15,2015 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE 5111-7473 rev.10/03/2015 BEFORE USE. )- Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and tens systems,see ANSI/TPIl Quality Criteria.DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria,VA 22314. Suite 109 Citrus Heiohts.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659576 PL14-412_UP_NEW F25 GABLE 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:33:07 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl l-9oioWtrwP42G_CLW09B4aVit2gD_M?tnEGLFA6iyTQnQ D-4e Scale=1:35.4 3x6 FP= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 o a o e o d a o o- e s o o-5— o o e e $ 38 N N a o a a o 0 0 o x) ) 0 0 0 o x) 37 'I 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 3x6 FP= 1 1-40 1 2-8-0 i 4-0-0 1 5-4-0 l 6-8-0 1 8-0-0 1 9-4-0 1 10-8-0 1 12-0-0 l 13-4-0 1 14-8-0 1 16-0-0 1 17-4-0 1 18-8-0 1 20-0-0 1 21-6-12 1 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-6-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.10 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 19 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:100 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.18Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.18Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY REACTIONS. All bearings 21-6-12. BRACED AGAINST LATERAL MOVEMENT(I-E. DIAGONAL WEB). (lb)- Max Gray All reactions 250 lb or less at joint(s)36,19,35,34,33,31,30,29,28,27,26,25,24,23,22, 21,20 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. ��GIN -FR /� 2 8 I 2PE #01"r co �0?, OREGO r J i 9�, cc�8ER \1 OS A- HECk EXPIRES:06/30/2017 October 15,2015 A WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MO-7473 rev.10/03/2015 BEFORE USE Design valid for use only with MTeku connectors.This design a based only upon parameters shown,and is for an individual building component,notMil a truss system.Before use,the building designer must verify the appficabitty of design parameters and properly incorporate this design into the overall �B building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` B always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandra.VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659577 PL14-412_UP_NEW F26 Floor 3 1 Job Reference(ootionall Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:08 2015 Page 1 ID:c53KNf9S8dZANgLpvMEnZkyCdl1-d_GAjlxlrLOrgV5Cjvbp2wP90dCOk9xOV?_je8yTQnP 1 1-0-4 I 2-6-0 1 0.1,8 Scale=1:41.5 4x6= 3x4= 3x4= 3x4= 3x8 FP= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 e e _m— !...4N 7 -Nit V_ / ! 7777 . NNe 7/ 21 t, 20 19 18 17 16 15 14 13 3x4 = 4x8= 3x6 FP= 3x5= 3x5= 4x6= 3x4= 1.5x3 SP= 0-ar8 24-4-12 0-h-8 24-3-4 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 027 Vert(LL) -0.23 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.56 Vert(TL) -0.39 15-16 >748 360 BCLL 0.0 Rep Stress Ina- YES WB 0.74 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:122 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1062/0-5-4,19=1062/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1782/0,3-4=-1782/0,4-5=-3190/0,5-6=-3190/0,6-7=3366/0,7-8=-3366/0,8-9=-2315/0,9-10=-2315/0, 10-11=-2315/0 BOT CHORD 18-19=0/600,17-18=0/2626,16-17=0/2626,15-16=0/3419,14-15=0/2982,13-14=0/1316 WEBS 11-13=-1631/0,11-14=0/1238,8-14=827/0,8-15=0/475,6-16=-283/0,4-16=0/699,418=1045/0,2-18=0/1464, 2-19=-1200/0 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)19. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. •\<� D PRpFFss �c� �NGjNEF6) iQ29 87022PE yCC T �Aj, OREG N 2c(,U 'AO AMBER 'V\ Or, He?, EXPIRES:06/30/2017 October 15,2015 111M ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MIF7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mick®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSI-89 and BCSI Building Component Safely InformationSuite 109 available from Truss Plate Institute,218 N.Lee Sheet.Suite 312,Alexandria,VA 22314. Slims H9iphlS.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659578 PL14-412_UP_NEW F27 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Wed Oct 14 15:3308 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-d_GAj1 x1 rLOrgV5Cjvbp2wPBvdHakGDOV?Je8yTQnP I 1-7-4 I 2-30 I 011,8 Scale=123.3 1.5x3 II 1.5x3 = 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 = 1J 2 3 4 5 6 7 _ _ e 13 d c 0 N A N%r-. Z X , Nrk, - q' e e 12 1d 10 9 • 3x4= 3x5= 3x5 = 3x4= I 13-5-12 13-5-12 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) l/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.14 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.20 Vert(TL) -0.06 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(TL) 0.01 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:70 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=582/0-5-4,11=582/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-888/0,34=-888/0,4-5=-958/0,5-6=958/0 BOT CHORD 10-11=0/463,9-10=0/1038,8-9=0/608 WEBS 6-8=-783/0,6-9=0/450,2-10=0/546,2-11=-697/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)CAUTION,Do not erect truss backwards. • REO P R°FFs �c3 t.�GINEF'7 sso2 z 87022PE vi- i yN r0/ 0'0OREGO ryeAU "PO FM8ER1\ NI r)O%a A HES; EXPIRES:06/30/2017 October 15,2015 ar WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MB-7473 rev,10/03/2015 BEFORE USE. 1 11 Design valid for use only with MTek@ connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate tha designminto the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mi)T eke is always requced for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCS/Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,216 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heiohts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659579 PL14-412 UP NEW F28 FLOOR SUPPORTED GABL 25 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:09 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZlcyCdl1-5AgYxNyfbfVinegPGc62a7yO_1guTnoXkfkHAayTQnO I 1-0-8 1.15x3 II 1 3x4= 2 Scale=1:13.2 0 R N T 4 :►41 �i 1.5x3 II 354= 1-3-8 03 1-3-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.06 Vert(LL) 0.00 4 "' 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=64/1-3-11,3=64/1-3-11,3=64/1-3-11 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. @��\(, & NEF9 `r/0 2 (� 87022PE ,-" / y �Aj, OREGO tic:',Ili -5!. ‘,1/M&ER \1 .\ EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev,10/03/2015 BEFORE USE. MI.. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate the design into the overall building design.Bracing indicated a to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTP11 Quality Criteria,DSI-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Rate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Suite 109 Citrus HeiaMs,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659580 PLT4-412_UP_NEW F29 FLOOR SUPPORTED GAEL 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:33:09 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1 5AgYxNyftrtW SegPGrr2a7yoD1 gwTnoXkfkHAayTQno 1 0-10-12 1. 3 II 1 3x4= 2 Scale=1:13.2 TO 0 N N 1 ����������..4. 1.5x3 II 3x4= p 1-1-12 I 0-63 1-1-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.04 Vert(LL) 0.00 4 ..`. 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-1-12 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=56/1-1-15,3=56/1-1-15,3=56/1-1-15 FORCES. (Ib)-Max.Comp-/Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �(�`c , GIN4- we Q 870 2PE 9 -7 5. SAT OREGO lL Q<vU' 'A�, F'ySER -\ C' �S A. HE. EXPIRES:06/30/2017 October 15,2015 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITFX REFERANCE PAGE MIF7173rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall t building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek* ek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Crterla,DSB-89 and SCSI Building Component 7777 Greenback Lane Safely Infonna9on available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659581 PL14-412_UP_NE W F30 FLOOR SUPPORTED GABL 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Wed Oct 1415:33:09 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-5AgYxNyfb(W SegPGc62a7yOd1 gzTnoXklkHAayTQno 1.5x3 I I 1 4x4= 2 Scale=1:13.3 L , : \ d L 4 3 1.5x3 II 4x4 = p 0-9-12 1 0-0'-4 0-9-12 Plate Offsets(X,Y)— 11:Edpe,0-1-81,f3:Edpe,0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL- in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.02 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight 9 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 OF No.18Btr(flat) TOP CHORD Structural wood sheathing directly applied or 0-9-12 oc purlins, except BOT CHORD 2x4 DF No.18Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=38/0-10-0,3=38/0-10-0 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Gable requires continuous bottom chord bearing. 2)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 3)Gable studs spaced at 1-4-0 oc. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ���� o P R()Fess 87022PE c eN ,-vIv SAT OREG•N 95),...41/ "2 F�jS E R O' OS A. i- EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITI(REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 11" Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall budding design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek- is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI-Building Component 109uite Safety Informotion available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria,VA 22314. Suite Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659582 PL14412_UP_NEW F31 FLOOR SUPPORTED GABL 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:09 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd115AgYxNyfbf1A4SegPGc62a7y0_1 guTnoXldkHAayTQnO I 1-0-8 1.5x3 II 1 3x4= 2 I Scale=1:13.2 L " d I • 4 ������������ -\,a. ♦ 1.5x3 II 3x4= p 1-3 i 0.0.3 1-3-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (lac) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.06 Vert(LL) 0.00 4 """ 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=64/1-3-11,3=64/1-3-11,3=64/1-3-11 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <<-REO P R Ores -�GINEER /�2 ct- 87022PE 9r' N CV ySAS 'OREG•N c <V9O /1/18ER \1 �`J SSA. HEA EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2010 BEFORE USE. leg'" Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the apptcablity of design parameters and properly incorporate this design into the overall building design.Bracing indicated is io prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/WPii Qualify Crtieda,DSB•89 and BCSI Building Component S e GO Greenback Lane Safety Information valable from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659583 PL14-412 UP NEW F32 Floor Supported Gable 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 1415:33:10 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd I1-ZMOwBizHMzeZ3oFbgKdH7LVZgR07CE W hyJTgjOyTQnN 1 2 3 4 Scale=1:13.0 _ _ J L 0 • 8 7 6 5 I 3-7-0 I 3-7-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 0 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:19 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-7-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) TRUSS TO BE FULLY SHEATHED FROM ONE FACE OR SECURELY REACTIONS. All bearings 3-7-0. BRACED AGAINST LATERAL MOVEMENT(I.E- DIAGONAL WEB). (Ib)- Max Gray All reactions 250 lb or less at joint(s)8,5,7,6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �\`oo� .. GIN S/O 2 87022PE -t' / 5. N 7 fi-c>, OREGON rP A(/ 9 ' O M8ER '‘..\ r Oka A. HER�P EXPIRES:06/30/2017 October 15,2015 ,_x.... . .;yam,.: ; ®WARNING-Ved fy design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE*111.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall '` building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Milek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery.erection and bracing of trusses and truss systems.see ANSI/1911 Qualtiy Criteria,DSS-89 and SCSI Building Component Suite 109 Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312 Alexandria,VA 22314. Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659584 PL14-412_UP_NEW F33 FLOOR SUPPORTED GABL 1 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 5 Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:10 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCd11-ZMOwBizHMzeZ3oFbgKdH7LVYSR03C E2hyJTgjOyTQnN I 1-4-0 L 1.5x3 II 1 3x4= 2 Scale=1:13.2 7 4 1.5x3 II 3x4= 1-7-0 I 0-1-2 1-7-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.10 Vert(LL) 0.00 4 "•• 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:12 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-7-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=80/1-7-2,3=80/1-7-2,3=80/1-7-2 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. -se ,t4..., 87022PE 9t— tP rN tAi - 0'O), OREG N cc-4[// 9O F,ygER A\ �. OSA. HON EXPIRES:06/30/2017 October 15,2015 • m ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE 1.01-7473 rev.10/03/2015 BEFORE USE, Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall budding design.Bracing indicated is to prevent buckling of individual inns web and/or chord members only.Additional temporary and permanent bracing MiTeke is always required for stability and to prevent colkspse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and SCSI BuBddng Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659585 PL14-412_UP_NEW F34 FLOOR SUPPORTED GABL 1 1 Job Reference(ootional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 Mitek Industries,Inc.Wed Oct 14 15:33:10 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-ZMOw8izHMzeZ3oFbgKdH7LVZWR0DCE2hyJTgjoyTQnN 7x10 II 1 2 Scale=1:13.3 • _ o 0 N 4 3 7x10 II 0-- 0-7-4 I 2 0-7-4 Plate Offsets(X,Y)— 11:Edoe,0-1-81.14:Edge,0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.01 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/fP12007 (Matrix) Weight:9 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 0-7-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=26/0-7-6,3=26/0-7-6 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Gable requires continuous bottom chord bearing. 2)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 3)Gable studs spaced at 1-4-0 oc. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��co �tJG NEER /0 k 87022PE 91' 7 -cj, OREGON (yam„(1., "PC.OAMBER 11 S A. HO; EXPIRES:06/30/2017 October 15,2015 ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE r Design valid for use only with Mick®connectors.This design is based only upon parameters shown,and is for an individual building component,not . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and properly damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/D.11 Qualify Criteria,DSB-89 and SCSI Building Component Suite 109 Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heiahts,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659586 PL14-412_UP_NEW F35 FLOOR SUPPORTED GABL 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:11 2015 Page 1 ID:c53KNI9S8dZANgLpvMEnZkyCdll-1 ZyIM2zv7GnQhygn018WWY1jfrMHxhHgBzDNFTyTOnM 1-5-4 1.5x3 II 1 3x4= 2 Scale=1:13.2 0 N ��������••A++�I • 1.5x3 II 3x4= 1-8-4 1 1-8-4 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) l/deft lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.11 Vert(LL) 0.00 4 "'"" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 3-4 >999 360 BCLL 0.0 Rep Stress Ina' YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:12 lb FT=0%F,0%E LUMBER- BRACING- - TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-8-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=86/1-8-5,3=86/1-8-5,3=86/1-8-5 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <rD PRQi Co �`. �NGINEFR /O9 870 2PE 1' CI) cNi y (N.4)), OREG N cy� <U 'A0 �M8ER ,'` .p psA. HO\ EXPIRES:06/30/2017 October 15,2015 N ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE 6(11-7473 rev.10/03/2015 BEFORE USE. �- Design valid for use only with MEek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the appkcabiility of design parameters and properly incorporate this design into the overall k building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mi TT ek* is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/T9I1 QuaMy Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659587 PL14-412_UP_NEW F36 FLOOR SUPPORTED GABL 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:11 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-1 ZylM2zv7GnQhygn018WtY1jMrMMxhHgBzDNFTyTQnM I 1-1-4 1.15x3 II 1 3x4= 2 Scale=1:13.2 0 F., 1.5x3 II 304= 0-(J-2 1-4-4 1-4-4 1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.07 Vert(LL) 0.00 4 "` 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incl YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-4-4 oc purlins, except BOT CHORD 2x4 DF No.18&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=68/1-4-6,3=68/1-4-6,3=68/1-4-6 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. •\<<-REp PROFESS 87022PE �1' / �' f � c�T OREGON -c' 1� 'AO AMB E R -\ - OS A. HECk EXPIRES:06/30/2017 October 15,2015 t ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. I Design valid for use only with Mick®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Qualify Criteria,DSB-89 and BCSI Banding Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria.VA 22314. Suite 109 Citrus Heights CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659588 PL14-412_UP_NEW F37 FLOOR SUPPORTED GABL 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:11 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-1 ZyIM2zv7GnOhygn018WIY1 k?rMQxhHgBzDNFTyTQnM 1.5x3 II 1 454= 2 Scale=1:13.3 0 0 0 N N 4 3 1.5x3 I I 4x4= 0-11-0 0-0-1 0-11-0 Plate Offsets(X,YI— (1:Edoe.0-1-81.f3:Edae,0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.03 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incl. YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight 10 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 0-11-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=44/0-11-1,3=44/0-11-1 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Gable requires continuous bottom chord bearing. 2)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 3)Gable studs spaced at 1-4-0 oc. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <<-C\ D P R OFFS �F9 s/o29r � �G,N 870 2PE y �Aj OREG N rN.0 111sER ,1 OSA HER‘4.P EXPIRES:06/30/2017 October 15,2015 _ f ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the appicabitty of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPIl Quality Cdteda.DSB-89 and SCSI Bonding Component 7777109 Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45659589 PL14-412_UP_NEW F38 Floor Supported Gable 2 1 Job Reference(ootional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 S Jul 11 2014 MiTek Industries,Inc.Wed Oct 14 15:33:12 2015 Page 1 ID:c53KNt9S8dZANgLpvMEnZkyCdl1-VlVhZO_XuavHJ6PzylflCmavlEicg8XzQdyxnvyTOnL 1-0.0 1.5x3 II 1 3x4= 2 Scale=1:132 p , 4 4 1.5x3 II 3x4= 1-3-0 1-3-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) 0.00 4 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-3-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=62/1-3-0,3=62/1-3-0,3=62/1-3-0 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. P R2% � 870 2P tP N tc'�OT OREG N QCU $MBER OS A. HECk EXPIRES:06/30/2017 October 15,2015 AMP e ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 1111111 Design valid for use only with Mrrek0 connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the appricabitty of design parameters and properly incorporate this design into the overall !MeV building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication.storage,delivery,erection and bracing of trusses and truss systems.see ANSI/TP11 Quality Criteria,DSB-89 and!SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 SOUS Heights,CA 95610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 1 3/" Center plate on joint unless x,y p 4 (Drawings not to scale) offsets are indicated. Damage or Personal Injury MEDimensions are in ft-in-sixteenths. 4.1.46„. Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal orx-bracing,is always required. See BCSI. TOP CHORDS 2. Truss bracing must be designed by an engineer.For 0-1/1e, 4 wide truss spacing,individual lateral braces themselves _ may require bracing,nors alternativeeredTor I illIllAor 1111 pbracing should be considered. 1_ O= 3. Never exceed the design loading shown and never Al d stack materials on inadequately braced trusses. ~ c-a ca- cs• O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate designer,erection supervisor,property owner and plates 0- S 'from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE Joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. *Plate location details available In Mitek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design Is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER 3907,ESR 2362,ESR 1397,ESR 3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions Indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and In all respects,equal to or better than that ifr! Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 14.Bottom chords require lateral bracing at 10 ft.spacing, section 6.3 These truss designs rely on lumber values or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but ©2012 Mitek®All Rights Reserved approval of an engineer. ■aiiii* reaction section indicates joint - number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 18.Use of green or treated lumber may pose unacceptable ► environmental,health or performance risks.Consult with Industry Standards: 111project engineer before use. ANSI/TPI1: National Design Specification for Metal 111111.at19.Review all portions of this design(front,back,words and pictures)before use.Reviewing pictures alone Plate Connected Wood Truss Construction, isnot sufficient. DSB-89: Design Standard for Bracing. i'1eJ( e BCSI: Building Component Safety Information, 20.Design assumes manufacture In accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.10/03/2015