LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 14:16:13sy-eV F 1 ;
WARNING
ATI ti,',
i
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY' 4 C ?V�
*** WOOD—E DESIGN 2_014,:1 EXPIRES ON 3/31/2016. LP WELL MAKE ?AVAILABLE TO D -C i Y"
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD—E DESIGN SOFTWARE IN �;�;v i' i, .L'-i..
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, �„1t, `; j < Itc'
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. Il
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 FLOOR BEAM 1
STATE: OR CODE: IRC
PRODUCT: 1-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR ROOF BEAM (UNFACTORED LOADS)
LIVE DEAD SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) CARRIED CARRIED SLOPE LOADING LIVETOTAL
30 15 17.000' 15.000' 0.00 SIDE L/240 L/180
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3085 6257 3014 0.111 0.167
ALLOWABLE 3085 9093 3948 0.415 0.554
STRESS INDICES 1.00 0.69 0.76 L/900 L/595
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS,
**** ALLOWABLE DEFLECTIONS ARE RASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
** COMPRESSION EDGE BRACING REQUIRED AT 68" O.C. OR LESS.
*** THIS LVL BEAM HAS BEEN DESIGNED TO SUPPORT A 300 LBS CONCENTRATED
LOAD ACTING OVER 2.5 X 2.5 FT (6.25 SQ.FT)
STRUCTURAL GEOH E''R.Y
SPAtJ
8.500,
TOTAL SPAN: 8.50 FT
LOAD PATTERN;
-------------
CASE SPAN SHAPE TYPE SOURCE LOADING i',-(_;--.);-- WI W2 X1
____ _ (FT)t X2 (FT)
+ALL 1 U JIB' i.E� i',-(_;--.);-- SIDE-Po- ----21;T-0:--E-11; ------------ '(;7)T,;(-)--
87;6T)--
+
+AL1: 1 UNIF WEIGHT BEAM 5.9 ELF 0.000 8.500
+1 1 UNIF LIVE ROOF SIDE 480.0 ELF 0.000 8.500
+2 1 UNIF LIVE ROOF SIDE 0.0 PLF 0.000 8.500
3 1 UNIF LIVE ROOF TOP 48.0 PLF 0.196 2.695
4 I UN.I E LIVE ROOF TOP 48.0 ELF ...804 8.304
5 1 UNIF LIVE Ry�Ov
TOP 48 0 -LF 3.000 .1.500
-
+ INDCATES LOAD S BASE ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD ?SF.
Page 2
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1
6257 3014 1.00
2 2120 1021 0.90
3 2201. 1122 1.00
4 2201 1122 1.00
5 2332 1081 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
-------------------------
CASE BRG#1'. BRG#2
1 3085 3085
2 1045 1045
3 1145 1066
4 1066 1145
5 1105 1105
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1045 1045
2 1045 1045
3 1045 1045
4 1045 1045
5 1045 1045
REACTIONS FOR LIVE LOAD
CASE' 3RG#1 BRG##2
1 2040 2040E
2 0 0
3 100 20
4 20 100
5 60 60
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
2.351 2.351
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.111 0.415 L/900 0.167 0.554 L/595
2 1 0.000 0.415 0.057 0.554 L/1756 0.057 0.085
3 1 0.002 0.415 L/40329 0.059 0.554 L/1684
4 1 0.002 0.415 L/40329 0.059 0.554 L/1684
5 1 0.005 0.415 L/19497 0,062 0.554 L/1611
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
--------------
1 0.69 0.76
2 0.26 0,29
3 0.24 0.28
4 0.24 0.28
5 0.26 0.27
Page 3
SLENDERNESS RATIO = 6.79 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP,
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 14:28:54
WARNING
-------
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016, LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 FLOOR BEAM 2
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
------------------------------
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
PS ') (PS?) LOAD CARRIED CARRIED LOADING LIVE TOTAL
____- -__-- ---- -------- -------- --___-- _-_------- ---------
40
, 15 NO 17.000' 15.000SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS,
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
*..*--------------..-----------------------------__________
ACTUAL 6285 21379 6196 0.376 0.527
ALLOWABLE 9363 27280 11845 0.460 0.690
STRESS INDICES 0.67 0.78 0.52 L/441 L/314
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF .16d (3-1/2") NAILS AT 6" OC.
FROM ONE FACE ONLY. STAGGER ROWS, FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 6" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131", I6d SINKERS (3-1/4")
MAY BE USED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 468 PLF LDE: 1 .00
NOTES
-----
*** COMPRESSION EDGE BRACING REQUIRED AT 56" 0.C. OR LESS.
STRUCTURAL GEOMETRY
-------------------
SPAN 1
14.000'
TOTAL SPAN: 14.00 FT
LOAD PATTERNS
- -
CASE SPAN SHAPE TYPE SOURCE LOADING W1 52 51 FT; X2 (FT)
Page 2
+ALL 1 *UNIF DEAD FLOOR SIDE 240.0 PLF 0.000 14.000
+ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 14.000
+1. 1 *UNIF LIVE FLOOR SIDE 640.0 PLF 0.000 14.000
+2 _ *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 14.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 21379 6196 1.00
2 6139 1779 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
6285 6285
2 1805 1805
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1805 1805
2 1805 1805
REACTIONS FOR LIVE LOAD
CASE BRG#' BRA#2
1 4480 4480
2 0 0
MINIMUM BEARING SIZES (IN)
--------------------------
BRG# 1 BRG# 2
2.378 2.378
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW, L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.376 0.460 L/441 0.527 0.690 L1314
2 1 0.000 0.460 0.151 0.690 L/1095 0.151 0.227
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
*** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
--------------
1 0.78 0.52
2 0.25 0.17
SLENDERNESS RATIO = 2.26 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FCR ERRORS RESULTINNG FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 16:39:17
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE W000-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 FLOOR BEAM 3
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 17.000' 7.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 8528 41005 8475 0.536 0.757
ALLOWABLE 8528 47475 15960 0.628 0.941
STRESS INDICES 1.00 0.86 0.53 L/422 L/299
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
----------
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF I6d (3-1/2") NAILS AT 10" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 10" OC. TO THE JN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN.
MAX. LOAD: 468 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 35" O.C. OR LESS,
STRUCTURAL GEOMETRY
-------------------
SPAN I
--------
19.000'
TOTAL SPAN: 19.00 FT
Page 2
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (F)
+ALL 1 *UNIF DEAD FLOOR SIDE 180.0 PLF 0.000 19.000
+ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 19.000
ALL 1 CONC DEAD FLOOR TOP 841.4 LBS 12.500
+1 1 *UNIF LIVE FLOOR SIDE 480.0 PLF 0.000 19.000
1 1 CONC LIVE FLOOR TOP 2243.6 LBS 12.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 19.000
2 1 CONC LIVE FLOOR TOP 0'-'.0 LBS 12.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 4100x; 8475 1.00
2 11940 2476 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
----------------------------------------------- „
REACTIONS FOR TOTAL LOADS -
CASE BRG#1 BRG#2
1 7554 8528
2 2226 2492
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2226 2492
2 2226 2492
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
5328 6036
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
1.918 2.166
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1. (FT) MIN BRG (IN)
1 DEAD 841.4 12.500 3.000 - -
1 LIVE 2243.6 12.500 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/2 INSTANT LONG-TERM
1 1 0.536 0.628 L/422 0.757 0.941 L/299
2 1 0.000 0.628 0.221 0.941 L/1023 3.221 0.331
*** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH
FOR CANTTLEVERS (2L) .
STRESS INDICES CASE MSI VSI
1
_____________-
0.86 0.33
2 0.28 0.17
Page 3
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 18:02:57
WARNING
*** THIS DESIGN IS;,VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 FLOOR BEAM 4
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR :FLOOR BEAM (UNFACTORED LOADS;
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LI` E TOTAL
40 1.5 NO 17.000' 7.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 11394 20674 11408 0.219 0.305
ALLOWABLE 11394 27280 11845 0.361 0.541
STRESS INDICES 1.00 0.76 0.96 L/593 L/425
LOAD CASE 1 1 1 1 1
***A THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2")
NAILS AT 6" OC.
FROM ONE FACE ONLY. STAGGER ROWS'. FLIP BEAM AND ATTACH THE THIRD
PLY WITH ROWS OF 16d (3-_./2") NAILS AT 6" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.132". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 468 PLF LE_: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 60" O.C. OR LESS,
STRUCTURAL GEOMETRY
SPAN 1
11.300'
TOTAL SPAN: 11.00 FT
Page 2
LOAD .PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 XI (FT) X2 (FT)
+ALL 1 *UNIT DEAD FLOOR SIDE 180.0 PLF 0.000 11.000
+ALL 1 UNIF WEIGHT BEAM 17,8 PLF 0.000 11.000
ALL 1 CONC DEAD FLOOR TOP 1714.1 LBS 2.000
ALL 1 CONC DEAD FLOOR TOP 841.4 LBS 2.000
+1 1 *UNIF LIVE FLOOR SIDE 480,0 PLF 0.000 11.000
1 1 CONC LIVE FLOOR TOP 4570.9 LBS 2.000
1 1 CONC LIVE FLOOR TOP 2243.6 LBS 2.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 11.000
2 1 CONC LIVE FLOOR TOP 0.0 LBS 2.000
2 1. CONC LIVE FLOOR TOP 0.0 LBS 2.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF,-
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) EDF
1 20674 11408 1.00
2 5792 31.81. 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1
11394 5432
2 3179 1553
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 3179 1553
2 3179 1553
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRC,#2
1 8216 3879
2 0 0
MINIMUM BEARING SIZES (1N)
BRG# 1 BRG#
2.894 1.500
CONCENTRATED LOADS
------------------
SPAN TYPE W1 (LBS) X1 (FT) MIN' BRG (IN)
1 DEAD 1714.1 2.000 3.000
1 DEAD 841.4 2.000 3.000
1 LIVE 4570.9 2.000 3.000
1 LIVE 2243.6 2.000 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.219 0.361 L/593... 0.305,... 0.541 L1425.
2 1 0.000 0.361 0.086 0.541 L/1508 0.086 0.129
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN TS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
Page 3
STRESS INDICES CASE MSI VSI
--------------
0.96
2 0.24 0.30
SLENDERNESS RATIO = 2.26 0.76 0.96
= 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED, LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 18:08:48
WARNING
-------
'** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016, LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 FLOOR BEAM 5
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSY) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
-------- -------- ------- ---------- ---------
40 15 NO 7.500' 15.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 10324 43175 10284 0.503 0.708
ALLOWABLE 10324 47475 15960 0.594 0.891
STRESS INDICES 1.00 0.91 0.64 L/425 L/302
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS,
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16a (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
***MAXIMUM SIDE LOAD FOR MULTI-PLY CONNECTION DESIGN
MAX. LOAD: 413 PLF LDF: 1.00
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 29" O.C. OR LESS.
STRUCTURAL GEOMETRY
-------------------
SPAN I
--------
18.000'
TOTAL SPAN: 18.00 FT
Page 2
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE --ss168.8 ?LF 0.000 18.000
+ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 18.000
ALL 1 CONC DEAD FLOOR TOP 1714.1 LBS 5.000
}'11 *UNIF LIVE FLOOR SIDE 450.0 PLF 0.000 18.000
1 1 CONC LIVE FLOOR TOP 4570.9 LBS 5.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 18.000
2 1 CONC LIVE FLOOR TOP 0.0 LBS 5.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (%B--FT) SHEAR (LBS) LDF
43175 10289.��.__�... ..._...6..
1.00
2 12406 2960 0.90
UNFACTORED SUPPORT REACTIONS (LES) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 10324 7531
2 2973 2211
REACTIONS FOR DEAD LOAD
-
CASE BRG#1 BRG#2
1 2973 2211
2 2973 2211
REACTIONS FOR LIVE LOAD
CASE BRG##1 BRG#2
1 7351 5320
2 0 0
MINIMUM BEARING SIZES (IN)
M
BRG# 1 BRG# 2
2.622 1.913
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) Xl (FT) MIN BRG (TN)
1
DEAD 1714.1 5.000 3.000
1 LIVE 4570.9 5.000 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. Li? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.503 0.594 L/425 0.708 0.891 1/302
2 1 0.000 0.594 0.205 0.891 1{1045 0.205 0.307
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MST VSI
1 0.91 0.64
2 0.29 0.21
Page 3
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 18:21:02
WARNING
-------
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSTS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 GARAGE DOOR HEADER H1
STATE: OR CODE: IRC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVI 2650Th-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
---------------------------------------------------
:: RR
VE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
_ ----- ----- ---- -------- -------- ------- ---------- ---------
FLOOR 15 NO 2.000' 17.000' TOP L/360 L/240
ROOF 30 15 0.000 0.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
------------------------------------------- -
ACTUAL 9538 38857 10971 0.323 0.541
ALLOWABLE 14155 47475 15960 0.538 0.807
STRESS INDICES 0.67 0.82 0.69 L/599 L/358
LOAD CASE 3 3 1 3 3
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
-------
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*'* CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
-----
*** COMPRESSION EDGE BRACING REQUIRED AT 40" O.C. OR LESS,
STRUCTURAL GEOMETRY
-------------------
SPAN 1
--------
16500'
TOTAL SPAN: 16.50 FT
LOAD PATTERNS
Page 2
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD ROOF TOP 240.0 PLY 14.000 16.500
+ALL 1 UNIF DEAD FLOOR TOP 142.5 PLF 0.000 16.500
ALL 1 UNIF DEAD FLOOR TOP 127.6 PLY 0.000 16.500
+ALL 1 UNIF DEAD WALL TOP 100.0 .PLY 0.000 16.500
+ALL 1 UNIF WEIGHT BEAM 24.0 PLY 0.000 16.500
ALL 1 CONC DEAD ROOF TOP 1962.7 LBS 14.000
1 1 UNIF LIVE ROOF TOP 360.0 PLE 14.000 16.500
+1 1 UNIF LIVE FLOOR TOP 285.0 PLY 0.000 16.500
1 1 UNIF LIVE FLOOR TOP 255.3 PLY 0.000 16.500
1 1 CONC LIVE ROOF TOP 2944.0 LBS 14.000
2 1 UNIF LIVE ROOF TOP 0.0 PLF 14.000 16.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLY 0.000 16.500
2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 16.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 14.000
+3 1 UNIF LIVE FLOOR TOP 380.0 PLF 0.000 16.500
3 1 UNIF LIVE FLOOR TOP 340.4 PLF 0.000 16.500
4 1 UNIF LIVE ROOF TOP 480.0 PLF 14.000 16.500
4 1 CONC LIVE ROOF TOP 3925.3 LBS 14.000
INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 37068 10971 1.00
2 15485 4545 0.90
3 38857 9398 1.00
4 21523 8259 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
-------------------------
CASE BRG#1 BRG#2
1 8566 13259
2 3595 5472
3 9538 11415
4 4280 9911
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1
3595 5472
2 3595 5472
3 3595 5472
4 3595 5472
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2 �
1 4971 7787
2 0 0
3 5943 5943
4 686 4440
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.595 5.013
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) XI (FT) MIN BRG (IN)
1 DEAD 1962.7 14.000 3.000
1 LIVE 3925.3 14.000 3.000
Page 3
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.304 0.538 L/638 0.521 0.807 L/372
2 1 0.000 0.538 0.218 0.807 L/890 0.218 0.326
3 1 0.323 0.538 L/599 0.541 0.807 L/358
4 1 0.083 0.538 L/2327 0.300 0.807 L/646
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
___-----------
1 0.78 0.69
2 0.36 0.32
3 0,82 0.59
4 0.45 0.52
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 18:32:31
WARNING
-------
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016, LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS,
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 GARAGE DOOR HEADER H2
STATE: OR CODE: IRC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (A) ALLOWABLE DEFLECTION
(PSF) (PSE) LOAD CARRIED CARRIED LOADING LIVE TOTAL
------- -----
FLOOR 40 15 NO 2 000' 17.000TOP L/360 L/240
ROOF 30 15 0.000' 34.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
---------------------------------------------------------------
ACTUAL 6629 13398 4933 0.106 0.179
ALLOWABLE 6629 18187 7897 0.276 0.414
STRESS INDICES 1.00 0.74 0.62 L/941 L/557
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT ANI SHEAR DATA ABOVE ARE BASED ON T.IE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS,
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE. LENGTH FOR CANTILEVERS (2L) .
CONNECTION
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 160 (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 160 SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT 62" C.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
8.500'
TOTAL SPAN: 8.50 FT
LOAD PATTERNS
-------------
CASE SPAN SHAPE TYPE SOURCE LOADING W' Ig"; Xi (FT) X2 (FT)
------
IALL 1 UNIF DEAD ROOF TOP 255.0 PIE 0.000 8.500
+ALL 1 UNIF DEAD FLOOR TOP :42.5 ULF 0.000 8.500
Page 2
ALL 1 UNIF DEAD FLOOR TOP 127.6 PLF 0.000 8.500
+ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 8.500
-,-1. 1 UNIF LIVE ROOF TOP 382.5 PLF 0.000 8.500
+1 1 UNIF LIVE FLOOR TOP 285.0 PLF 0.000 8.500
1 1 UNIF LIVE FLOOR TOP 255.3 PLF 0.000 8.500
+2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 8.500
'2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500
2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500
+.3 1 UNIF LIVE FLOOR TOP 380.0 PLF 0.000 8.500
3 1 UNIF LIVE FLOOR TOP 340.4 PLF 0.000 8.500
+4 1 UNIF LIVE ROOF TOP 510.0 PLF 0.000 8.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSI.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
--------------- -- -
1 13398 4933 1.00
2 5472 2022 0.90
3 11659 4295 1.00
4 9852 3631 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
--------------------------------------------------------------------
REACTIONS FOR TOTAL LOADS
-----_------------------
CASE BEGS 1 BRG#2
---- ----- -----
1 6629 6629
2 2707 2707
3 5769 5769
4 4875 4875
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2707 2707
2 2707 2707
3 2707 2707
4 2707 2707
REACTIONS FOR LIVE LOAD
-----------------------
CASE DRG#1 BRO#2
---- ----- -----
1 3922 3922
2 0 0
3 3062 3062
4 2168 2167
MINIMUM BEARING SIZES (IN)
ERGS 1 BEGS 2
-------- --
2.525 2.525
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. Id? INSTANT LONG-TERM
1 1 0.106 0.276 L/941 0.179 0.414 L/557
2 1 0.000 0.276 0.073 0.414 L/1363 0.073 0.109
3 1 0.083 0.276 L/1206 0.155 0.41.4 L/640
4 1 0.058 0.276 L/1703 0.131 0.414 L/757
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
Page 3
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
-------------- ---- ----- -----
1 0.74 0.62
2 0.33 0.28
3 0.64 0.54
4 0.54 0.46
SLENDERNESS RATIO - 3.39 LIMIT - 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS,
USF OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICT:,Y PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2014.1 12/02/15 18:42:20
WARNING
-------
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2014.1 EXPIRES ON 3/31/2016. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW, LLC
JOB ID: 1871 ENTRY DOOR HEADER H3
STATE: OR CODE: IRC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR COMBINATION ROOF AND FLOOR BEAN (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
-------- ---------- ---------
FLOOR 40 15 NO 0.000 0.000' TOP L/360 L/240
ROOF 30 15 5.000' 13.000' TOP
FLOOR SPAN CARRIED IS NOT CONTINUOUS. ROOF SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
-------------------- ---
ACTUAL 5578 7362 5182 0.062 0.102
ALLOWABLE 5578 11932 6318 0.212 0.317
STRESS INDICES 1.00 0.62 0.82 L/1225 L/750
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THI.. ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
CONNECTION
----------
*** DESIGN ASSUMES ALL "TOP" LOADS ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
ADDITIONAL FASTENERS MAY BE REQUIRED.
NOTES
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT,
STRUCTURAL GEOMETRY
SPAN 1
6.500'
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
-------------
CASE SPAN SHAPE : Yp5 SOURCE LOADING WI W2 X1 (FT) X2 (ET)
Page 2
+ALL 1 UNIF DEAD ROOF TOP 135.0 PLF 0.000 6.500
+ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500
+ALL 1 UNIF WEIGHT BEAM 9.5 PLF 0.000 6.500
ALL 1 CONC DEAD ROOF TOP 1692.3 LBS 5.000
+1 1 UNIF LIVE ROOF TOP 270.0 PLF 0.000 6.500
1 1 CONC LIVE SNOW TOP 3384.7 LBS 5.000
+2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500
2 1 CONC LIVE ROOF TOP 0.0 LBS 5.000
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 7362 5182 1.00
2 2716 1906 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
-------------------------
CASE BRG#1 BRG#2
1 2844 5578
2 1185 2096
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1185 2096
2 1185 2096
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1659 3481
2 0 0
MINIMUM BEARING SIZES (IN)
----------_— _-_--------
BRG# 1 BRG4 2
-------- --------
1.500 2.125
CONCENTRATED LOADS
------------------
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 1692.3 5.000 3.000
1 LIVE 3384.7 5.000 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 I 0.062 0.212 L/1225 0.102 0.317 L/750
2 1 0.000 0.212 0.039 0.317 L/1931 0.039 0.059
**A* FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. **,*
*'** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) ,
STRESS INDICES CASE MSI VSI
1 0,62 0.82
2 0.25 0.34
SLENDERNESS RATIO - 2.71 LIMIT - 10.00
Page 3
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.