Permit CITY OF TIGARD ELECTRICAL RESTRICTED ENERGY PERMIT COMMUNITY DEVELOPMENT Permit#: ELR2016-00206 T tGAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/23/2016 Parcel: 1 S 135AB01004 Jurisdiction: Tigard Site address: 10220 SW GREENBURG RD 530 Project: AG Spanos Corp Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Fire alarm. Contractor: SAFE TECHNOLOGY GROUP INC Owner: LINCOLN CENTER LLC 6400 NE HWY 99 STE G375 BY SHORENSTEIN PROPERTIES LLC VANCOUVER,WA 98665 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 360-699-2130 PHONE: FAX: 360-719-1527 FEES Description Date Amount Specifics: Restricted Energy Permit 08/23/2016 $75.00 12%State Surcharge-Electrical 08/23/2016 $9.00 Type of Use: COM Class of Work: ALT Total Number of Systems: 1 Audio&Stereo: 0 Boiler Controls: 0 CCTV: 0 Clock Systems: 0 Data&Telecommunications: 0 Fire Alarm: 1 HVAC: 0 Instrumentation: 0 Intercom/Paging: 0 Landscape/Irrigation: 0 Landscape Lighting: 0 Medical: 0 Nurse Calls: 0 Protective Signal: 0 Security Alarm: 0 Other: 0 Total $84.00 Other Desc: Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: c- .ermittee Signature: Ckk - 2.(, v J\ x OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE: Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Electrical Permit Applicatiox" 't r, a �A' ' ` 1011011 1( 1.. r.SI.()NI N City of Tigard Received ci g DateB : 0 ;L, 6.t J Permit No.: i ( t 13125 SW Hall Blvd.,Tigard,OR 97223 r 9a ; l�.l �.J t �� ' 11 Phone: 503.718.2439 Fax: 503.598.1960�l1`' "� tit -�� t;,- Plan Review Other Permit: DateB : f --Lb/ t l( A, i:) Inspection Line: 503.639.4175 e Date Ready/By: H See Page 2 for Internet: www.tigard-or.gov ' F. ' ,,,. .t:r Notified/Method: t Supplemental Information 'i - . . s a.:: : INC�€.N ; L IO I'`I AI�I Il t ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked below): ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition 0 Other: where the available fault current 0 Marinas and boatyards. C ESORV exceeds 10,000 amps at 150 volts or 0 Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural ❑ 1-and 2-family dwelling E Commercial/industrial 0 Accessory building amps for all other installations. buildings. ❑Multi family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of75 KVA or J .Sll 1 ❑Emergency system. larger separately derived system. , 0 Addition of new motor load of 0"A","E","1-2","1-3", Job no.: Job site address:10220 SW GREENBURG RD 100HP or more. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP:TIGARD OR 97223 0 Health-care facilities. 0 Supply voltage for more than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.:440534=' Project name:AG SPANOS CORPORATION 0 Service or feeder 600 amps or more. 7 !Ni-i''.!.. E Cross street/directions to job site:LINCOLN 2 Description ir-Qty. 1" Fee. I Total 'I * New residential single-or multi-family dwelling unit Includes attached garage. Subdivision: Lot no.: 1,000 sq,ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential with above ft. 75.00 2 r. . +•' R1ik?"C lO#r .,( � � `` Limited energy,multi-family 75.00 2 FIRE ALRM residential(with above sq.ft.) Services or feeders installation,alteration,and/or relocation 200 amps or less 100.70 2 ' ' , IERTY..owNER' :-. - }3 TE,1NtAl f amps to 400 amps 133.56 2 201 Name: 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Address: Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or City/State/ZIP: relocation Phone:( ) Fax:( ) 200 amps or less 59.36 I 201 amps to 400 amps 125.08 2 Owner installation:This installation is being made on property that I own which is not 401 amps to 599 amps 168.54 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. Branch circuits—new,alteration,or extension,per panel Owner signature: Date: A.Fee for branch circuits with ro -r P 'I,ICon, ` above service or feeder fee, P each branch circuit 7.42 2 Business name:SAFE TECHNOLOGY GROUP INC. B.Fee for branch circuits without service or feeder fee,first 56.18 2 Contact name:JASON SWEET branch circuit Each add'l branch circuit 7.42 2 Address:6400 NE HWY 99 SUITE G375 Miscellaneous(service or feeder not included) City/State/ZIP:VANCOUVER WA 98665 Each manufactured or modular 67.84 2 dwelling,service and/or feeder Phone:(360)699-2130 Fax::(360)719-1527 Reconnect only 67.84 2 Pump or irrigation circle 67.84 2 E-mail:SALES@SAFETECHNOLOGY.NET Sign or outline lighting 67.84 2 "' CONTRACTOR- Signal circuit(s)or limited-energy Business name:SAFE TECHNOLOGY GROUP INC. panel,alteration,or extension. 1 Page 2 75.00 2 Each additional inspection over allowable in any of the above Address:6400 NE HWY 99 SUITE G375 Additional inspection(1 hr min) 66.25/hr City/State/ZIP:VANCOUVER WA 98665 Investigation(1 hr min) 66.25/hr Industrial plant(1 hr min) 78.18/hr Phone:(360)699-2130 Fax:(360)719-1527 Inspections for which no fee is 90.00/hr s(tecifically listed(V2 hr min) CCB Lic.: 173731 Electrical Lic.: CLE79 Suprv.Lic.: 4272LEA CERICA `;PERMIT "" " �, - Subtotal: 75.00 Suprv.Electrician signature,required: Plan review(25%of permit fee): Print name: JASON SWEET Date: 8/22/16 State surcharge(12%of permit fee): ��. et, TOTAL PERMIT FEE: 11_ Authorized signature: wa7l'h �3-t�A This permit application expires if a t pp' p permit is not obtained within 180 days after it has been accepted as complete. Print name: ADAM SWEET Date: 8/22/16 * Number of inspections allowed per permit. I:\Building\Permits\ELC-PermitApp.doc 07/01/10 440-4615T(11/05/COM/WEB Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10220 SW GREENBURG RD 530, TIGARD, OR, 97223 Commercial - Electrical Limited Energy 198 Low voltage final PASS - No C of O ELR2016-00206 Jeff Grove Violation Summary: Inspector Contractor