Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
�l sw Loze RECEIVED ,.•. .•. JUN 8 2016 '% 'VAT TTY TIGARD FIRE PROTECTION, INC 9095 S.W. Burnham Tigard, OR 97223 SHOE MILL TI WASH SQ 9585 SW WASHINGTON SQ RD, #L02B TIGARD, OR 97223 r FIRE PROTECTION EQUIPMENT SUBMITTAL t ,CL1 Worldwide Contacts www.tyco-fire.com Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General stallation or finish. The tip of the Pro- tective Cap can be used to mark the Description center of the ceiling hole into plaster p board or ceiling tiles by gently push- The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- "Royal Flush II" Concealed Pendent tective Cap. When ceiling installation # sk Sprinklers Quick Response (3-mm is complete, the Protective Cap is re- Sprinklers moved and the Cover Plate/Retainer bulb)Y and Standard Response (5-mm Assembly is installed. ' bulb), are decorative sprinklers featur- inga flat coverplate designed to con- 9 As an option,the Series RFII Standard � y ,z.`` ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be eas such as hotel lobbies,office build- fitted with a silicone Air and Dust Seal. ings,churches,and restaurants. (Refer to Figure 5.) The Air and Dust • TY3531 (3 mm Bulb) is UL Listed, Seal is intended for sensitive areas CUL Listed, VdS Approved (Certif Each sprinkler includes a Cover Plate/ icate No. , and NYC A G4090007 Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and proved (MEA 353-01-E) as Quick Support Cup Assembly. The separa- dust from the area above the ceiling to Response. ble, two-piece assembly design pro- pass through the cover plate. vides the following benefits: • TY3531 (3 mm Bulb) is FM and NOTICE LPCB Approved (Ref. No. 094a/10) • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. and pressure testing of the fire pro- Sprinklers described herein must be Factory Mutual and LPCB do not tection system prior to installation p of a suspended ceiling or applica- installed and maintained in compli- approve any concealed sprinklers tion of the finish coating to a fixed ance with this document and with the for quick response. ceiling. applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and ceiling panels for access to building ties having jurisdiction.Failure to do so NYC Approved (MEA 353-01-E) as service equipment without having may impair the performance of these Standard Response. to first shut down the fire protection devices. system and remove sprinklers. Approvals for Air and Dust Seal The owner is responsible for maintain- • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- UL and C-UL Listed for use with the vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure sprinkler drops. with any questions. The Series RFII Sprinklers are shipped Maximum 250 psi (17,3 bar) by UL, C-UL,and NYC with a Disposable Protective Cap.The Sprinkler Protective Cap is temporarily removed p Maximum 175 psi (12,1 bar) by FM, during installation and replaced to help Identification VdS,and LPCB protect the sprinkler during ceiling in- Temperature Rating Number (SIN) 155°F(68°C)Sprinkler with IMPORTANT TY3531 — 3 mm bulb 139°F(59°C)Plate - Always refer to Technical Data Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200°F(93°C)Sprinkler with WARNING" that provides cautions 165°F(74°C) Plate with respect to handling and instal- Technical Discharge Coefficient lation of sprinkler systems and corn- K=5.6 GPM/ si1i2 �2(80,6 LPM/bar� ponents. Improper handling and in- Data p ) stallation can permanently damage Adjustment a sprinkler system or its components Sprinkler Approvals 1/2 inch(12,7 mm) and cause the sprinkler to fail to Approvals apply only to the service operate in a fire situation or cause it conditions indicated in the Design Cri- Finishes to operate prematurely. teria section. See the Ordering Procedure section. Page 1 of 4 MARCH 2013 TFP181 TFP181 Page 2 of 4 Physical Characteristics 1/2" NPT % SEALING Frame Bronze , ' ASSEMBLY Support Cup Chrome Plated Steel ' / ` Guide Pins Stainless Steel FRAME Deflector Bronze Compression Screw Brass CAP Bulb Glass /�i `�4 \ Cap Bronze or Copper Sealing Assembly Beryllium SUPPORT Nickel w/TEFLON CUP WITH L___ BULB 1 $ Cover Plate Brass ROLL FORMED Retainer Brass THREADS Ejection Spring Stainless Steel I I COMPRESSION Design = SCREW GUIDE mr Criteria PINS(2) / The TYCO Series RFII 5.6 K-factor, DEFLECTOR � l "Royal Flush II" Concealed Pendent ' 7—I. I (DROPPED Sprinklers are intended for fire protec- DEFLECTOR i iC— i i POSITION) -7---Lt r z 3./ tion systems designed in accordance � — with the standard installation rules rec- ognized by the applicable Listing or I SPRINKLER/SUPPORT CUP Approval agency;for example, UL List- ASSEMBLY ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. THREAD INTO P I RETAINER WITH THREAD For more information on LPCB and CUP UONTIL \ O 0 ) DIMPLES VdS Approvals, contact Tyco Fire Pro- MOUNTING tection Products at the following office: SURFACE IS EJECTION Enschede,Netherlands FLUSH WITH SPRING Telephone:31-53-428-4444 CEILING Fax:31-53-428-3377 The Series RFII Concealed Pendent _.�� ■ ---- Sprinklers are only listed and approved — with the Series RFII Concealed Cover - Plates having a factory applied finish. SOLDER COVER TABS(3) COVER PLATE/RETAINER PLATE NOTICE ASSEMBLY Do not use the Series RFII in applica- FIGURE 1 tions where the air pressure above MODEL RFII CONCEALED SPRINKLER the ceiling is greater than that be- ASSEMBLY low. Down drafts through the Sprin- kler/Support Cup Assembly can delay Installation Do not attempt to compensate for in- sprinkler operation in a fire situation, sufficient adjustment in the Sprinkler The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- Operation "Royal Flush II" Concealed Pendent kler/Support Cup Assembly. Re-adjust p Sprinklers must be installed in accor- the position of the sprinkler fitting to When exposed to heat from a fire, the dance with this section. suit. Cover Plate, normally soldered to the General Instructions Step 1. Install the sprinkler only in the Retainer at three points, falls away to Do not install any bulb-type sprinkler if pendentf the sprinkler position with the center-line expose the Sprinkler/Support Cup the bulb is cracked or there is a loss perpendicular to the Assembly. mounting surface. of liquid from the bulb. With the sprin- Step 2. Remove the Protective Cap. The Deflector — supported by the kler held horizontally, a small air bub- Guide Pins — then drops down to its ble should be present. The diameter Step 3. With pipe thread sealant ap- operational position. of the air bubble is approximately 1/16 plied to the pipe threads, hand-tighten inch (1,6 mm)for the 155°F (68°C)and the sprinkler into the sprinkler fitting. The glass bulb contains a fluid that ex- pands 3/32 inch(2,4 mm)for the 200°F(93°C) Step 4. Wrench-tighten the sprinkler when exposed to heat. Whenn temperature ratings. using only the RFII Sprinkler Wrench. the the rated temperature is reached, the (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the A leak-tight 1/2 inch NPT sprinkler joint Sprinkler Wrench to the Sprinkler as glass bulb, activating the sprinkler and should be obtained by applying a min- shown in Figure 3. allowing water to flow. imum to maximum torque of 7 to 14 Step 5. Replace the Protective Cap ft.-lbs. (9,5 to 19,0 Nm). Higher levels by pushing it upwards until it bottoms of torque can distort the sprinkler In- out against the Support Cup. (Refer let with consequent leakage or impair- to Figure 4.)The Protective Cap helps - ment of the sprinkler. prevent damage to the Deflector and TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER . DIAMETER - HOLE y FITTING ` DIMENSION C J SPRINKLER l�l`111 I_ SUPPORT CUP — ASSEMBLY I 1 ; 1/2"(12,7 mm) 1 1.11 ;,, THREADED D ADJUSTMENT �I Al. Mali FACE `j I.I– OF CEILING, A' . RETAINING RING ,,,,o,, i MOUNTING 1 SURFACE \ ;� \ I FIGURE 4 - \ 'i DISPOSABLE PROTECTIVE CAP i.\ . I I Arms during ceiling installation and/or =z� r_ _ --� finish.You can also use the Protective I T -~ Cap to locate the center of the clear- 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE ance hole by gently pushing the ceiling (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER material up against the center point of REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY the Protective Cap. COVER PLATE COVER PLATE NOTICE -PROFILE DEPTH DIAMETER As long as the Protective Cap remains DIMENSION B DIMENSION A in place, the system is considered A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) "Out of Service': B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) Step 6.After the ceiling has been com- pleted with the 2-1/2 inch(63,5 mm)di ameter clearance hole and in prepa- FIGURE 2 ration for installing the Cover Plate/ SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Retainer Assembly, remove and dis- card the Protective Cap.Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the l=l. FRAME j=l Deflector does not move up and down ARM % ;or freely, replace the entire Sprinkler. ____/— \ 1; Do not attempt to modify or repair a damaged sprinkler. SUPPORT _ l _ li,\:„, Step 7. When installing an Air and - CUPI IDust Seal, refer to Figure 5;otherwise, iproceed to Step 8. To attach the Air i and Dust Seal, verify the angle of the II M1WI ��������/ IMI i �III�� outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the 7/8” (23 mm) 0 Air and Dust Seal and continue around SQUAREthe retainer until the entire Air and Dust Seal is engaged. ••-__,--,_ Step 8. Screw on the Cover Plate/ ALIGN / �� Retainer Assembly until the Retainer ARROWS WITH i 1 i \ (shown in Figure 2)or the Air and Dust FRAME ARMS Seal (shown in Figure 5) contacts the � 4= rl ceiling. Do not continue to screw on ACCEPTS i i the Cover Plate/Retainer Assembly \� �' so that it lifts a ceiling panel out of its 0 1/2"SOCKET –r normal position. If you cannot engage DRIVE the Cover Plate/Retainer Assembly FIGURE 3 with the Support Cup or you cannot RFII SPRINKLER WRENCH engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Care and SUPPORT — SPRINKLER FACE OF ORIENT Maintenance CUP CEILING SEAL ( j�l _- , � BEVEL AS COVER '�' SHOWN The TYCO Series RFII 5.6 K fac- ' PLATE :) tor, "Royal Flush II" Concealed Pen- dent MEM Sprinklers must be maintained ,, ASSEMBLY and serviced in accordance with this ,�section. _ Before closing a fire protection system i' P �_main control valve for maintenance 4jAIR work on the fire protection system that ■" //Ii AND DUST it controls, obtain permission to shut ..—=ice•—� �--. LIP OF COVER SEAL down the affected fire protection sys- RETAINER PLATE tern from the proper authorities and FIGURE 5 notify all personnel who may be affect- OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) ed by this action. Absence of the Cover Plate/Retainer If you must remove a sprinkler, do not Assembly can delay sprinkler opera- reinstall it or a replacement without re- tion Ordering in a fire situation. installing the Cover Plate/Retainer As- Procedure When properly installed, there is a As- sembly. If a Cover Plate/Retainer As- nominal 3/32 inch(2,4 mm) air gap be- sembly becomes dislodged during Contact your local distributor for tween the lipof the Cover Plate and the service, replace it immediately. availability. When placing an order, ceiling,as shown in Figure 2. The owner is responsible for the in- indicate the full product name. spection, testing, and maintenance ofThis air gap is necessary for proper Sprinkler/Support Cup Assembly fireprotection system and devic operation of the sprinkler. If the ceil- ing requires repainting after sprinkler es in compliance with this document, Specify: Series RFII (specify SIN), installation, ensure that the nsw nkler as well as with the applicable stan- K=5.6, "Royal Flush II" Pendent Sprin- does not seal suany the air gap. dards of the National Fire Protection klers (specify) temperature rating and Association(e.g.,NFPA 25), in addition (specify)finish, P/N(specify). Do not pull the Cover Plate relative to to the standards of any other authori- the Enclosure. Separation may result. ties having jurisdiction.Contact the in- 155°F(68°C1 200°F(93°C) Sprinklers which are found to be leak- - stalling contractor or sprinkler manu- TY3531 51-792-1-155 51-792-1-200 ing or exhibiting visible signs of corro- sion regarding any questions. Tv3551 51-790-1-155 51-790-1-200 must be replaced. Automatic sprinkler systems should be Separately Ordered Cover Plate/ Automatic sprinklers never be inspected,tested,and maintained by a Retainer Assembly: Automatic plated, coated,mustu, or other-e qualified Inspection Service in accor- p dance with local requirements and/or Specify: (temperature rating from be- wise altered after leaving the factory. national code. low) Series RFII Concealed Cover Modified sprinklers must be replaced. Plate with(finish), P/N(specify). Sprinklers that have been exposed to 139°F(59°C)(a) 165°F(74°c)(b) corrosive products of combustion, but Grey White have not operated,should be replaced (RAL9002) 56-792-0-135 56-792-0-165 if they cannot be completely cleaned Brass 56-792-1-135 56-792-1-165 by wiping the sprinkler with a cloth or Pure White(c) by brushing it with a soft bristle brush. (RAL9010) 56-792-3-135 56-792-3-165 Signal White Care must be exercised to avoid dam- (RAL9003) 56-792-4-135 56-792-4-165 age to the sprinklers - before, during, Jet Black and after installation. Sprinklers dam- (RAL9005) 56-792-6-135 59-792-6-165 aged by dropping, striking, wrench Brushed twist/slippage, or the like, must be re- Chrome 56-792-8-135 56-792-8-165 placed.Also,replace any sprinkler that Chrome 56-792-9-135 56-792-9-165 has a cracked bulb or that has lost Custom 56-792-X-135 56-792-X-165 liquid from its bulb. (Ref. Installation (a) For use with 155°F(68°C)sprinklers. Section.) (b) For use with 200°F(93°C)sprinklers. (c) Eastern Hemisphere sales only. Exercise care to avoid damage to sprinklers before, during, and after in- Sprinkler Wrench stallation. Replace sprinklers damaged Specify: RFII Sprinkler Wrench, by dropping, striking, wrench twisting, P/N 56-000-1-075. wrench slipping, or the like. Also, re- place any sprinkler that has a cracked Air and Dust Seal bulb or that has lost liquid from its Specify:Air and Dust Seal, bulb. (Refer to the Installation section.) P/N 56-908-1-001. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. tL,C17 Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers "' • Description described herein must be installed and , maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright (TY313) and Pendent(TY323) standards of the National Fire Protec Sprinklers described in this data sheet tion Association,in addition to the stan- i are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair —...z—'-: „‘.,,, ) sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and — ` devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: 5, • A two-piece Style 15 Recessed Sprinkler Escutcheon with recessed adjust- Identification 1,4,:\ l„.<'"*'` 4 .. *.I.T.' ' v.,. ment up to 5/8 inch (15,9 mm)from the flush pendent position. Number (SIN) ,. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2-NPT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. „. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175°F(79°C) 200°F93°C TY-FRB Sprinklers are described in UL and C-UL Listed 286°F 141°C Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved ( ) kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON derwriters Laboratories,Inc.(UL). Bulb Glass Always refer to Technical Data Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi112(80,6 LPM/bar112) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause • it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 ' 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* r,..... I r irTl'�Eri\�� L/rrilir-$\ _ 5 � � 7/16" �= (11,1 mm) f 1■Fc 4 NOMINAL 2" l� (I MAKE-IN �q (50,8 mm) I m Er 2 �• 1 2" 1-3/8" 3 �> (50,8 mm) (34,9 mm) J I or / WRENCH - 1 1 fp- C ` FLATS t 1/2" NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. —.- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) ....."-./ (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- . kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) �, Sprinklers are intended for fire pt Loi temperature ratings. tion systems designed in accordance with the standard installation rules rec- A leak-tight 1/2 inch NPT sprinkler joint should be obtained b applying ognized by the applicable Listing or Y a min- Approval agency(such as, UL Listing mum to maximum torque of 7 to 14 �• All is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels �..� 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment INTO ENSURE Data Sheets).Only the Style 15 or Style of the sprinkler. ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1, apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers 1 \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16° �j,/ -1 I I Sprinklers must be installed in actor MI (9,5±7,9 mm) Vii\"" 'r + } dance with the following instructions. } / j, 4+ Step A.After installing the Style 15 or MOUNTING NW 1/8" i 1 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) it kler threads, and with pipe-thread --- - sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4" sprinkler fitting. (19,1 mm) Step B. Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the W-Type SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7spriRecessed Sprinkler Wrench(Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4"DIA. ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2" (12,7 mm) Mounting Plate until its flange comes in + - FLUSH contact with the ceiling. MI Care and f I 1 1/8" Maintenance SURFACEMOUNTING l- (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, - I Upright(TY313)and Pendent (TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8" (22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outeriece of an if they cannot be completely cleaned p by wiping the sprinkler with a cloth or Automaticmendtoinkler systems d are rec- escutcheon, which is used to cover by brushing it with a soft bristle brush. mended be inspected, tested, a clearance hole, can delay sprinkler and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ - cleaned by means of gently dusting slippage,or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of • sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX _ ( I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)** 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F93°C for example,77-370-4-175-I ( ) *•Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify")finish,P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish, P/N(specify") *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t„co TEFLON is trademark of The DuPont Corporation. `f Fire Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL (in) WEIGHT H (in) SIZE ., • 1 1.461 1.083 _ 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE IZE(in) SCHEDULE4 .. EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 • 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems t0 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at c us L L� II Ea,NY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 A LELO company e-mail:sales a,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 v= : ": : Ductile Iron Fittings - Class 300 UL/FM 14-01 • ,,, • c 01 us 44(11:0` APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Stze Pa"it Num�e'r1,,,,g,'‘`A i" , `Packing Weight ern : Inner-A, Master ,'Ib 4e - 1/2 35CP3004 138 200 4000 0.1 3/4 35Cp4,91)6m'I' 163 i00 00 . . OU ;a ,02.rri '®'� 1 35CP3010 1.75 60 120 0.4 '°1-114 35O3012r "" .,,,,2'.,.00 W 35 a2 d ry ';" . b.5 ' 1-1/2 35CP3014 2.19 25 50 0.7 . 2 3 :; .3026' T 2.62 , x,'15 1, , 3 ` ._i _ 1 2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size 0 �Part,Numbe Packing .. 1'';Weiight N - t;In in „t, *Inner r: Matters , lb a I A. A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1:x 3/4=. 5RG3010°° , : 1' 9 ' 6d'- M 1g a .0.4 ' %', _ 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 t2x 1(not 4x) £ 1iC3C}20Q102" 1w 'I 4 401 £'` ' 1: - , Fig. 35HB3 -Hex Bushing " Size l� Pa4lu1 r' e" A „� �. Packing Weight ` B the cry ` in _ Inner.' Master �,, %lb - � � °1„x 1/3/2 35HB�: �5FIB3010004.. ~s 1.06. ; 180. � 360 0.2 r IIIjr JA 1 80 , ' LR11-1/4 x 1 35HB3012010 1.19 90 180 0.2 I /2 r, -HB3d1401 f 4" 75 ;; 11 > 9A1,..w ,. Y 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x=I 3, 0` 6°f �40 K, .,x s ° .,." ` 9.6 z-" 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2. ,Y-1/.Y , 3 HB3° °°14 ce 1.36 .{ <,.. r .:,z80.•. :0.617, tir Fig. 35SP3 -Square Head Plug S e Part 11u er Packing eight Kn Innen Maste ' fb 0 1/2 35SP3004 0.94 600 1200 0.07 T, 37 1' 35SP30 12 3 1 I I1 1 35SP3010 1.25 200 400 0.1 4TI•'-'174' . .353 012 . - .. ''''m'' 10 Gr 2 4.;-0,3 .:,t, 1-1/2 35SP3014 1.44 80 160 0.4 2w, "x: 35 Q20n �`' 00, TT '44 45` 1 9t a4, 0:6 Fig. 35U 3- Union with Brass Seat A Size A `° Packing; „ � 4 Iliieight, ( � . � rt 'er ; F s� in in 0v' Inner - 'IVaster � Ib • -4-7---.. 1 35U 3010 2.19 20 40 1.0 ----------- 111-1/4 . y ,:,4'.3514:02,i07 '-2.66" rn ''''15.6; 36s 1 1-1/2 35U 3014 2.62 10 20 1.7 ' :I • 2 „ '1 ¢35U" 2044.4, .S1Y A '6 . 12r' "IP 2.4 113 SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com IP ARB NTEEL PIPE -H LE Ur PR D�1, T k r FireLocku i c LUSTEour FM VdS 9PCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1/2,3A,and 1715,20 and 25 mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Gasket: • Grade"E"EPDM -Type A (Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America,Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic° REV G 10.52 1 IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 i ) ,Y ® O>fit! t STYLE 922 • DIMENSIONS Nominal size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each Run X Branch .+0.06/41,5 11/4 X 1/2 3/16 1.30 1.83 1.10 3.87 2.56 1.0 V t `� 32 15 30.2 33 0 46.5 27.9 98.3 65.0 0.45 �� 3/a 1 3 20 30.23/16 32.51.28 46.51.83 21.107.9 95.387 652.56 0 0.510 i1,�,i�W ,�t1 1 25 13/16 1.52 2.18 1.10 3.87 2.56 1.2 �� 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 Y 13/16 1.42 1.95 1.22 4.08 256 1.2 • 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/a 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 230 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 h 13/16 1.66 2.19 1.46 4.60 2.56 13 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/a 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 j 30.2 , 47.8 64.5 37.1 116.8 65.0 0.68 21 /3 13/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/a 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/a 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 i 2.79 1.71 5.50 2.56 ( 1.7 25 30.2 54.1 I 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- . dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Ctia1V�1�. 10.52 2 REVG IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 F : .. € l STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size o Outlet Size 213,Section 16)(C=120)',FT 1'/a X 1 8.5 32 25 2.6 11/2 X 1 8.5 40 25 2.6 2 x 1 8.5 50 25 2.6 21/2 X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 • www.victaulic.com CtaU Ii C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. m..._..�.,�,-.a-,.,- REV G 10.52 3 IP ARB N TEEL PIPE H LE UT PR DU TSS ire cF STYLE 922 INSTALLATION Reference should always be made to the 1400 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 •ctaul ic' VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10,52 Pipe Hangers Fig. 200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) (DROLCO Fig. 200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) ' Fig. 200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) c. US Fig. 200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut QED ®' Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications _- %"�Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. -` Features: • (1/2" (15mm)thru 2" (00mm)) Flared edges ease installation for all pipe ® „ types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily , B installed around pipe. A ' For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" 12oomml) Spring tension on nut holds it securely in / i hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.zoa+/z.2oa3/, Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-2+/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel t ' materials will be supplied with (2) hex nuts " ( ,' in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of , ...... �� 4 FM DS 2-0. . - A C ... , , , ... , , , .. .*, .. . , , .„. . ' , .,.:0 Fig.200 tz Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.41 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8'-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" 185.71 25/8" (66.7) 12 (5.51 200-11/4 11/4" (321 3/8"-16 33/4" (94.0) 21/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 21/8" (73.01 14 (6.4) ' Fs,'> 200-2 2" (50) 3/8"-16 41/2" 1114.31 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 21 (12.3) 200-3 3" (75) 3/8"-16 51/8" (149.1) 4" (101.6) 29 (13.31 Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.31 34 (15.6) 200-4 4" (100) 3/8"-16 13/8' (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Q Fire Protection Solutions V-Line 21 by F:?•N Threaded Accessories B3205 - Threaded Rod (right-hand threads- both ends) (TOLCo Fig.103) B3205L -Threaded Rod (right&left hand threads) TL Size Range: 3/8"-16 thru 3"-4 rod Specif Length )l�lll�l1� Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL l�-') Rod is threaded on both ends with right hand threads of the length shown.Also ���1 available with left and right hand threads-specify Fig. B3205L when ordering. 0;0 Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. . Order By: Part number,rod size,length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (ram) Lbs. (kN) Lbs. (kN) "B3205-318 x'L:' ', 3/e"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L'A 1/2"-13 21/2" (63.5) ` 1350 (6.00) 1057 (4.70) B3205-5/8x'L"'' 5/8"-11 21/2 (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' , 3/4"-10 3" (76.2) 3230 (14.37) 2530 ' (11.25) B3205-'9 8;z`'L' ° '' 7/8"-9 31/2 (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 4,, 1"-8 4° (101.6) 5900 (26.24) 4620 (20.55) 'B3205-,1/ex'L's 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 133205-11/4x'12xs11/4"-7 5 (127.0) 9500 (42.25) 7440 (33.09) B320641/2 x!LP 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 0'21-713/4 x'L' ' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) • `14205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4x'12_, 21/4"-41/2 9° (228.6) 32300 (143.67) 25295 (112.51) B3205- 1 2X'L'1, 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'L' i 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 113205-3ux'L' 3 ' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 -All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length Cll) � Material: Steel �n1 �111������h1�111��� 7 -43 H Maximum Temperature: 750°F(399°C) .o Finish: Plain.Contact B-Line for alternative finishes and materials. m m Order By: Part number,rod diameter and finish F 0 a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. • ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) "'AIR 1/4"x 120 w .;99-1/4".,,,,length,, 20 240 (1.07) 12 (5.44) ;BTR 3/e"x 120 '¢3/s"x length 16 730 (3.24) 29 (13.15) ITR 1/2"x 120 99=1/2"`. lengt ; 13 1350 (6.00) 53 (24.04) AIR 5/a"x420 „ 99-1A"x length 11 2160 (9.60) 89 (40.37) TR 3/4"x 120 F ,, /4"x length,; 10 3230 (14.37) 123 (55.79) ATR 7/0"x 120',-?' 99-7/8"x length" 9 4480 (19.93) 170 (77.11) ATR 1"biz 120 A , 99-1"x length 8 5900 (26.24) 225 (102.06) Al dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Q Pipe Hangers&Supports 236 e..I'L� N Revised 4/28/2014 by i LT• SAMMY X-PRESS® SAMMYS . Sammy X-Press® it/s a':.ii7t0 P,?eta/Desi. Puf:;n. c Tuo+,l.it S:-,,e1 Product Features f� �' •The Sammy X-Press expands to provide •Installs in seconds,saving time& ( ) f• direct vertical attachment in: installation costs. 17 Patent No, j al 6,935,821 -Metal Deck(22-16 gauge) ,.-' -Z-Purlin(18-16 gauge) •Use in applications where access to the back of the installed fastener is •The Sammy X-Press Swivel allows you prohibited.ie.metal roof deck,tubular to hang plumb in extreme roof pitches: steel,or vapor barrier fabric. (SWXP) -89°in Z-Purlin r 14 II 45°in metal deck for12112 pitch •Less jobsite material needed. Patent Pending for •The Sammy X--Press Sidewinder expands •No retaining nut required. to provide horizontal attachment in: E (SXP) ex...rem -16 g -3/16"steel-purlin,tubular •Provides design flexibility. or �" Patent Pending ant steel. V art} roof pitches a prr • • • Rod , � s... ., 4 e 2.•_ t ► `FM 14waK'n Aaz �'RP4 motet Fecritn .1b, # Eoerk) /,t)oThick ` p •4aff-? ze tteer. .. t.." ,*.q.',..; u. & .,: : ad -. � ..-. k i2 •. ..: . VERTICAL MOUNT "` 1/4" 8181922 XP 200 X-Press 200 1146(22 a 185(Luminaire) .027" 9) 250(Luminaire) .056" 125" 25 125 Metal Deck '. :. %. • 'Q50(21i°AR' 7. .. "S Vii: t 940(2"Pipe)•.; .02T n. 3/8° 8150922 XP.20 If-Press 20 1146 22 a •,,,,,, 185(Lurri(nake) 11":•./,' # ( 9) 250(Luminaire) v- 4 (4•Ppe) ).:;027' 125" s'25 125 Metal Deck 283 Condu•t6t able 'g� 056' ;�. ', zs� v 1500(4'Pipe) .060° 3/8" 8153922 XP 35 X-Press 35 1783(16 85(Luminaire) 940 (2"Pipe) 105' 125' 25 125 Pudin `48 ga) 250(Luminaire) 1475(4°Pipe) .027' 416(Conduit&Cable) .056° 2. :y 70YPi 3 . . '' •• . 170'1 ertical(Lumkiai t - -" a`'" •l"Q;t....3/2y,:._8294922 .Dral; .SXP20..;°•,Swive ress20. o61(22 0 8045°(Lumina, 635''!.... • .0,.125' 25..• 125' '= Metal Deck:. ....0;1 ': •Atfdt:e,. .z - :n- 829(45'Off Vertical) 2283 vi fca(Lcondu18 Cable)" • ,„• s 4-. x 'I 1' `233 @ 4 (Conduct&Cable ,..4.... '' 4." 1500(4"Pipe) 1675(16 ga Vertical) 250 vertical(Luminaire) Q 3/8' 8295922 SXP 35 Swivel X-Press 35 1558(89°Off Vertical) 80 @ 90°(Luminaire) 635(2"Pipe) .060" •125' 25 125 Pullin 500 vertical(Conduit&Cable) 333 @ 89°(Conduit&Cable) .1";?.' ; ' -. . " .. . ` 1'P`iPourstructuralConcrete@3000psi"' Metal Deck — Q• -3/8" 8150922 XP 20 Sammy X-Press 20 ••1146 ga) 50(2%Pipe .'• 25 125 (Pre-Pour) `"' .��zz'iiiiii=eammiimmommi '" Post-Pour Range s 35 CF b Afetal Deck d -e. �', (I s u: Post-PA' 1250(3W Pipe) .. ` • 3/8" 8293957 SWXP35 SidewinderX-Press35 1798(16ga) 80(Luminaire) .060" .125" 25 125 Pudin ' n=., az ti,.t 416(Conduct&Cable) Pre-Pour Structural Concrete @ 3000 pal Post•Pour Range II LWCS 35 PCF(lbsl fV) J-I__/-\_ ..../1C.... -4-‘1 %,`. 6=E-J:1:1 6:qcP t'-', .-1 • zC . Sammy X Press It° INSTALLATION TOOL I. . 47r .a, • ,, m f UXPIT . { a ! K :f Patent Pending lla f i e" • tF. r \. " Part Number Model Description Each Cit .,81949}0 UXPIT*' Universal X-Press ltTod. 1 % -?r, '' 8195910 RXPIT Retro Socket for 8151910 1 ' '.' `� r>` 8152910 XPDB 25i�4"Dtj86it 1 r To watch a video demonstration of the Sammy X-Press,visit httplhvwwsammysuperscrew..comrsammyxpress.htm 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64'Drill Bd. For the most up to date information.visit www.sammysuperscrew.com 8 0 � l / Hr