Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (25)
7D cn( t/E-- Scholls Ferry Apartments Please scan the attached documents to each permit listed below: Bldg# Permit # Address 1 BUP2015-00361 13465 SW Hawks Beard St 2 BUP2015-00362 13375 SW Hawks Beard St 3 BUP2015-00363 13295 SW Hawks Beard St 4 BUP2015-00364 13205 SW Hawks Beard St 5 BUP2015-00365 13145 SW Hawks Beard St 6 BUP2015-00366 13351 SW Hawks Beard St 7 BUP2015-00367 13215 SW Hawks Beard St 8 BUP2015-00368 13435 SW Hawks Beard St 9 BUP2015-00369 13327 SW Hawks Beard St 10 BUP2015-00370 13225 SW Hawks Beard St 11 BUP2015-00371 13285 SW Hawks Beard St • I•VPIR Tualatin Valley Fire & Rescue DEC 1 6 ?I, Tualatin Valley Fire Flow and Hydrant Worksheet op Fire & Rescue BUILDIN1 � North Operating Center Central Operating Center South Operating Center 20665 SW Blanton Street 11945 SW 70th Avenue 8445 SW Elligsen Road Aloha,OR 97007 Tigard,OR 97223 Wilsonville OR 97070 Phone:503-259-1400 Phone: 503-649-8577 Phone: 503-259-1500 Fax:503-259-1224 Fax: 503-642-4814 Fax: 503-259-1520 Fire°F'l©wIId M +dtarit Worksheet This worksheet is required to be submitted to and approved by the Authority Having Jurisdiction (AHJ) before any permits for W, new building construction, building expansion or fire hydrants will be issued by any building department within the TVF&R District. For assistance completing this form,see the Fire Flow and Hydrant Worksheet Instructions or call the Operating Center nearest you. SECTION 1 - Preparer Information a. Preparer Name: Dean Masukawa Date: 12/10/2015 Phone: (503) 221-1121 Fax: (503) 221-2077 E-mail: dmasukawa@Irsarchitects.com b. Architect/Engineer of Record: Daniel C. Purgiel Phone: (503)221-1121 Fax: (503) 221-2077 E-mail: dpurgiel@Irsarchitects.com SECTION 2 -General Building Information a. Project Name: Tigard Apartments Buildings 1&6 Project Address: 135th and Scholls Ferry Rd City: Tigard County: Washington Zip: 97223 b. Construction Type: Type V-B c. Total Bldg Area: 29,124 sq ft(as defined by the OSSC) Total Fire Area: 29,124 sq ft(as defined by the OFC) Bldg Fire Flow: 4500 ' GPM(base amount without adjustment for occupancy hazard classification) d. Describe Fire Area: (if more than one fire area,include an 8 1/2 x 11 or 11 x 17 drawing indicating the various fire areas) Multi Family Residential-Buildings 1&6 e. Type of Occupancy or Use of Building: R-2 Page 1 Revised: October 2011 it FI©ri and Iy+dlrant Wor (continue . SECTION 3 -Occupancy Hazard a. Percentage of Occupancy Hazard Classifications (see Worksheet Instructions-tables 1 and 2) Occupancy Hazard Classification ,Fire Area : Totaf;F�reArea Light i-lazard 29124 SF .>I 29,124.:SF x 1Q0 �Percentof Fire Area : 100 Ordinary Hazard Grp 1 : 0 SF Ordinary.Hazard Grp 2.(HPCS I &<II} °: 0 SF Extra:Hazard Grp=1 (HPGS III} 0 SF Extra Hazard Grp 2(HPCS:IV&HH}., ..;. ; 0 SF t 29 t24 SF x_100 0:6fa Total must equal 100% : :100 Bio b. Calculated Fire Flow Occupancy Hazard Classification Factor . Erre Area Eire Elow Bldg Fire Flow; Light Hazard.. 0.75 x ##%, x 4500:GPM Ordinary Hazard Grp 1 0.85 3375 GPM 0`GPM Ordinary Hazard Grp 2 1:, x . 0 °�o'_ , x .:.. 4500 GPM. t O::GPM Extra Hazard'Grp 1 1 15 x 0 % x 4500:aGPM O:GPM Extra Hazard Gr 2 p <.1:25 ..... x :, 0:%, jC". 4500::GPM tit C. Required Fire Flow with Occupancy Hazard Adjustment ;.1375 ; GPM SECTION 4-Minimum Number of Fire Hydrants Required Refer to Table C105.1 below(2010 OR Fire Code, Appendix C)for the minimum number of hydrants required. Required Fire Flow: .. 3375 GPM TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS F111E-FLOW FREOUTREMENT MINpNUM NUMBER (9Pm) OF HYDRANTS _ -- 1,750 or less I 2, -2,250 2 2,500 3 [3.01 ) 3 3500-4,000 4 4,500-5,001:7 5 5,500 6 6,000 6 6,500-7,000 7 7,500 or more 8 or more Page 2 Revised: October 2011 Fire Flaw=and" dralntWorksheet(continued) I SECTION 5 -Reduction of Fire Flow Reduced by 75% for an approved automatic sprinkler system, installed in accordance with NFPA 13 or NFPA 13R (choose multiplier 0.25 in Section 6). SECTION 6 -Required Fire Flow Fire Flow: 3375 GPM x 0.25 ?.1500. ',; GPM (Min.=1500,Max.=3000) SECTION 7-Available Fire Flow to the Building Manually enter available fire flow here. Please attach documentation of the flow test that was conducted. It must include date, time and location of static/residual and flow hydrants, as well as the tester's name, phone number and address. Test Results: GPM Page 3 Revised: October 2011