Plans (50) DTQP-2.0 12-15-05
Accessories (Optional)
❑ Hot Water Coil Section
00
• 1/2"copper tubes 0 0O 0 0 0 0
• Aluminum ripple fins, 10 per inch .
- Connections:Male solder,5/8"for " ' l-- - ,r . r ,i
both 1-row and 2-row.Right hand A • iylr ifu
connections only on left hand units. %� i ii i�i//})
Left hand only on right hand units. JL JL_41,. p
- Galvanized steel casing
• Flanged duct connection.
- Coil is installed at induced air inlet.
t
ri
❑ 1Row ,-- T� -
r '-r- I. `---1
❑ 2 Row I
I L
R 1
I
••
k
1•Typi if
- S —M 9
Unit Size M(1 row) M(2 row) R S
2,3,4 1 1 1/4 17 15
5,6 1 1 1/4 25 171/2
R and S are inside dimensions.
Electric Coil Section ❑ ®i,Jlo,iai oi,n l.,unuuueu Clew le neater 0 uptwnal Lynergy Lontrolleo tlectnc Heater
Standard Features
• Single side access to low voltage, 31
high voltage,and electric heater
controls.
i
• Automatic reset thermal cutouts,one o o o 0 0.❑ 0
per element
•
• Single point electrical connection for - 1r P�7 <. - f
entire unit - ifi1- Heater Rack
• Positive pressure flow switch 3 o $j n Access Cover
• Flanged duct connection .UL_IL . . r
• Coil is installed at discharge of unit.
• Transformer • •
Options t - I1 _ am 1•Typ.
Fuse Block - 1 EuiIII
Disconnect switch,door r1 TI
40*
interlock type i L R
❑ Manual reset cutout
❑ Dust tight construction L_______JJ' •I__i S _
ID Mercury contactors r t
. 0
Supply Voltage - s T
❑ 208V, 1 ph,60Hz
❑ 240V, 1 ph,60Hz
❑ 277V, 1 ph,60Hz Unit Size U R S T
xLI uuv,s p11,ounc
480V,3 ph,60Hz(4 wire wye only) 2,3,4 31/2 14 11 2 1/8
5,6 91/2 16 1/2 14 1/2 3 1/8
R and S are inside dimensions.
DTQP-3.0 12-15-05
General Description
• Heavy steel casing,with leak • Adjustable SCR fan speed control Pressure independent primary
resistant construction. with minimum voltage stop. flow control.
- Dual density insulation,coated to - Bottom access panels can be - Single point electrical
prevent air erosion, meet removed for service. connections.
requirements of NFPA 90A and • Multipoint,center averaging - Rectangular discharge opening is
UL 181. velocity sensor. designed for flanged duct
• Energy efficient fan motor, • Primary air flow balancing connections.
permanent split capacitor type, connections.
mounted in vibration isolators.
This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus
reserves the right to make changes without written notice.
All rights reserved.No part of this work may be reproduced or transmitted in any form or by any means,electronic or mechanical,including photocopying and racedirg,or by any information storage retrieval system without permisson yr writing*DT Tomkins Industries,Inc
i c
TERMINAL UNIT WEIGH: tt-,:113, -"--/ *To us
* *if
gogs,,,,,, - Th„,.,,,,,„,,,„, ,,,,,, ,
,, .,,,..,,,,„,, , , on n
TQS
Size 20 g.. :_ - - Box w/ Pneumatic w/DDC or w/Electric Heat w/1 Row Coil w/2 Row Coil
immi�trols Analog
2 145 +4 +9 +25 +9 +12
3 150 +4 +9 +25 +9 +12
4 155 +4 +9 +25 +9 +12
5 220 +4 +9 +30 +17
6 +4 +9 +30 +12 +17
230 +4 +9 +30 +12 +1
TQP
Size 20 ga. Base Box w/ Pneumatic w/DDC or w/Electric Heat w/1 Row Coil w/2 Row Coil
Controls Analog
2 145 +4 +9 +25 +9 +12
J 1 5u +4 411111111111111111111111=1+ -rzo +9 +12
4 155 +4 +9 +25 +9 +12
5 220 +4 +9 +30 +12 +17
6 225 +4 +9 +30 +12 +17
Size 20 ga. a Pneumatic w/DDC or w/Electric Heat w/ w/2 Row Coil
Contro 9
2 113 +4 +10 +14
3 12 +4 +9 +23 +14
153 +4 +9 +23 +10
Note: Weights are approximate. Actual weight may vary based on specific options selected.