Loading...
Plans RECEIVED SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING I SURVEYING AUG 2 2016 9020 SW Washington Square Dr., Suite 505 P:sfaPortland,Oregon 97223 CITY OFTI (503)641.6311 F: (503)643.7905 GARD www.sfadg.com BUDDING DIVISION STRUCTURAL CALCULATIONS Brandenburger Residence Underpinning 13225 SW Shore Dr., Tigard, OR 97223 OFFICE COPY TerraFirma Foundation Systems CITY OP TIGARD REVIEWFp FOR CODE COMPLIANCE Approved ) OTC; [ ) - Pcrmit#: r-,,c-i-an I g oO O `7 (24O PROFF5, Address: 1,3 aaS O the#2 1-44 59022PE Date: pa ,4 / OREGON nnOeb ktio EY S. EXPIRES: 12-31-17 LIMITATIONS ENGINEER WAS RETAINED IN A LIMITED CAPACITY FOR THIS PROJECT.DESIGN IS BASED UPON INFORMATION PROVIDED BY THE CLIENT WHO IS SOLELY RESPONSIBLE FOR ACCURACY OF SAME.NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY,OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. Project No. TF16-039 August 1,2016 ir.7 r -r COPY t sfa SFA Design Group, LLE PROJECT NO.SHEET NO. STRUCTURAL I CIVIL I LAND USE PLANNING TF16-039 2of13 PROJECT DATE Brandenburger Residence Underpinning 8/1/2016 SUBJECT BY Pier Design Criteria KT I Structural Narrative The structural calculations and drawings enclosed are in reference to the design of the foundation underpinning of the two-story residence with a crawlspace located in Tigard, OR as referenced on the coversheet. The round steel tubes and retrofit brackets are used to stabilize and/or lift settling foundations. The bottom and back portion of the bracket is securely seated against the existing concrete footing. Pier sections are continuously hydraulically torqued into the soil below until a load bearing stratum is encountered. Lateral earth confinement and a driven external sleeve provide additional fixity to resist eccentric loading from the foundation. Once all piers are installed, they are simultaneously loaded with individual hydraulic jacks and closely monitored as pressure is applied to achieve desired stabilization and/or lift prior to locking off the pier cap. The piers are required to resist vertical loading from the masonry chimney. By inspection, soil friction acting on the existing unpiered portions of the concrete foundation is adequate to resist lateral loading on the structure. There is no ICC-ES report currently approved for underpinning systems within Seismic Design Category D or higher, thus the entire underpinning system has been reviewed and analyzed and is therefore a fully engineered system complying with all current codes and stamped by a licensed design professional. Deep foundation guidelines, load combinations, special inspection and testing requirements per IBC 2012 have been included.Axial and bending capacities of the external sleeve, analysis of the retrofit foundation bracket, design reductions, and corrosion considerations have been incorporated in all required calculations per AISC 360-10. Concrete foundation span capacities have been analyzed per AC1318-11. Bracket fabrication welding has been performed by Behlen Mfg Co. conforming to AWS D1.1 performed by CWB qualified welders certified to CSA Standard W47.1 in Division 2. In addition, Behlen Mfg Co. has received US99/1690 certification meeting ISO 9001:2008 requirements by ANAB accredited SGS. General Building Department City of Tigard Building Code Conformance(Meets Or Exceeds Requirements) 2012 International Building Code(IBC) 2012 International Residential Code (IRC) 2014 Oregon Structural Specialty Code(OSSC) 2014 Oregon Residential Specialty Code (ORSC) Dead Loads Masonry Chimney 39.0 psf Concrete 150.0 pcf airl SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING PROJECT NO. SHEET NO. PROJECT TF16-039 3 of 13 Brandenburger Residence Underpinning DATE SUBJECT 8/1/2016 Design Loads BY KT !Worst Case Vertical Design Loads Tributary Width To Anchor= =2.50 ft MasonryDL= (39 psf) (28.00 ft) = 1092 plf Dead Load 150 pcf) 3.668 kips FootingoL= { (15.00 in) (24.00 in) =375 plf Floor Live Load 0.000 kips Roof Snow Load 0.000 kips Wind Load(+) 0.000 kips Wind Load(-) 0.000 kips Seismic Load(-) 0.000 kips Controlling Load Combination: D+L IMax Vertical Load to Worst Case Pier 3.668 kips 1 Pier Layout p (A r NQTES: I 1. CON`IRAOTOR TO NO"IFY FNCINF=2 ON RFC`.ORP IF FE,D CO NDIT ONS OsFFER. 7 7 2 = 3h(✓h;;A ES L')...A,r ON1 gE;i Hh1PJ LY r11 (E) r;c:%C FOO1€%t I 3. INDICATES LOCAT ON O,- (E) CO\ISTENDVA_L I i I ON Of; CON::, FOOTING• J ' INDICATES LO�CAT ON 0 —5; I 1 '_ICAL PI -�v r� PER PACE 3 OF TIMI REPORT 1-_ -1- ' 1 I.— I S (0"ATRACToR TO VERIFY 1`-3''D x5'—o 'w CHIMNEY' = I tE. °ativi FOOTING '�e'3Th 1'-0" OF SOIL COVER J RGE ' 04 l— I I I I I I I I I I I 1 `_ 1PG4? 1 i (E)PARTIAL FOUNDATION/(N) PIER LAYOUT PLAN KEY PLAN SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING PROJECT N0. SHEET NO. PROJECT TF16-039 4 of 13 Brandenbur.er Residence Under.innin. DATE SUBJECT 8/2/2016 Foundation Su..ortworks HP288 Helical Pier S stem BY KT I Design Input PIER,/ Pier System Designation= HP288 REACTION Vertical Load to Pier, PTL= 3.668 kips PIER CAP WITH Minimum Installation Depth, L= 10.000 ft THREADED RODS 1� �AN 5FOOWNG Unbraced Length,I= 1.000 ft ••• AND OGTIG' Eccentricity,e= 4.250 in PIER Concrete to Steel Coefficient of Friction, p= 0.450 EXTERNAL SLEEVE (E) GRADE Friction Factor of Safety, FS= 2 _ I I Normal Surface Force, Fn= 1.834 kips Vertical Component of Tieback, PTB= 0.000 kips BRACKET— 11,P Design Load(Vertical+Tieback),PDL= 3.668 kips EXCAVATIO '71-111—i 1-11 I +MomentEccent c;ty= 15.587 kip-in (_ -Momentneback= 0.000 kip-in 1 -MomentFnction= 6.395 ki -in Design Moment, MomentPieroL= 9.192 kip-in I � I . Sleeve Property Input 117 1 i r i I [ 117,1111,7 Sleeve Length= 24.000 in 1 �� i1]771114— 111III „, Tr&L,1 , 1 Design Sleeve OD= 3.434 in Design Wall Thickness= 0.183 in1:71:"1-1_11: 1 1 EXTERNAL Note: Sleeve reduces bending stress on main r= 1.151 in 1 —!1! 1 (=5LEEUE pier from eccentricty A= 1.869 in s'— ?1 � 1 X11 FIERI S= 1.443 insr' I` Zr 1.936 ins I 1[ -HELIX BLADE (D3) I= 2.477 in4 �I -=I ) E= 29000 ksi l Fy= 50 ksi (1 I. l i W.F.- pip!propety Input ; PE--j--111,7=11;1( �,..11 I I«_ Design Tube OD= 2.801 in HELIX BLADE (02) 11 '( ? Design Wall Thickness= 0.239 in I �-1 k= 2.10 I-.... III�, .: '� r= 0.910in I (T:I�II _111_2 ti i�!� Note: Design thickness of pier and sleeve based A= 1.923 int �1 i; Helix Properties and Capacity Fyh= 50 ksi Fbh=0.75*Fyn= 37.500 ksi 5 of 13 Di = 10 in Ai =p*D12/4= 78.5 ins t� = 0.375 in Si =1*t12/6= 0.023 ins Qi =Al*wi = 38.4 kips wi = 0.488 ksi D2= 12 in A2=p*022/4-p*(Tube 00)2/4= 106.9 ins tz= 0.375 in Sz=1*t22/6= 0.023 ins Q2=Az*w2= 40.9 kips wz= 0.382 ksi D3= 0 in A3=p*D32/4-p*(Tube OD)2/4= 0.0 ins t3= 0.000 in S3= 1*t32/6= 0.000 ins Q3=A3*w3= 0.0 kips w3= 0.000 ksi Helix Weld to Pier Capacity EQ= 79.2 kips OK E70 Electrodes= 70 ksi Size of Fillet Both Sides= 0.250 in Capacity of Fillet Both Sides= 7.424 kli R� = 1.758 kli Weld OK R2= 1.758 kli Weld OK f Soil-Individual Bearing Method-cohesive R3 0.000 kli Factor of Safety= 2.0 Blow Count, N= 12 EAh= +A2 4-A3= 1.3 fts Cohesion, c= 1.500 ksf No= 9 Qu=.Ah(cNC)= 17.388 kips Qa,compressionftension=Qu/FS= 8.694 kips OK -4 Cohesive Controls Soil-Individual Bearing Method-Non-Cohesive Factor of Safety,FS= 2.0 y= 110 pcf 0= 32° Depth of Helix, Di = 10.000 ft Depth of Helix, 02= 7.500 ft Depth of Helix, D3= 0.000 ft q'i =y*Di = 1100.0 psf q'z=y*D2= 825.0 psf q'3=y*D3= 0.0 psf Nq= 1+0.56(12*0)°154= 20.04 (for 0=32°) Qiu=Ai(q'iNq)= 12.023 kips Qzo=A2(q'2Nq)= 12.277 kips Q3„=A3(q'3Nq)= 0.000 kips Qa,compressionftension=yQ„/FS= 12.150 kips OK !Soil-Torque Correlation Method-Verification Factor of Safety, FS= 2.0 Design Work Load,DL= 3.668 kips Emperical Torque Correleation Factor,Kt= 9 ft-1 Final Installation Torque,T= 3000 lb-ft Ultimate Pile Capacity,Qu= 27.000 kips Allowable Pile Capacity,Qa= 13.500 kips OK Results Max Load To Pier=Design Load=3668 lb 2.875"Diameter Pipe Pier with 0.276"Thick Wall 3.5"Diameterx24"Min Long Pipe Sleeve With 0.216"Thick Wall 0.375"Thick 10/12"Helix With 0.25"Fillet Welds Each Side of Helix to Pier Minimum 10'-0"Installation Depth And Minimum 3000 lb-ft Installation Torque ElSFA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I CIVIL I LAND USE PLANNING TF16-039 6of13 PROJECT DATE Brandenburger Residence Underpinning 8/1/2016 SUBJECT BY Foundation Supportworks FS288BL Bracket KT Capacity of 314"0 GRB7(125ksi)Threaded Rod T1 = 11 D= 0.750 in Ft= 125 ksi At= 0.344 in2 e = 4t/4" Capacity= 42.950 kips [ Block Shear at%"Plate 0 and ® to TBS= 0.3(58)(%)(11)+0.5(58)(%)(2) = 93.525 kips - R i Capacity of Weld® ," E70 Electrodes= 70 ksi ?� Size of Fillet= 0.188 in 3/8" SATE 1 /„ FATE a Length of Weld= 11.000 in I Capacity of Per Inch of Fillet= 2.784 kli 1 t l J f 1 Capacity of Fillet=30.627 kips I. I 6 Capacity of "Plate d 46" WELD 0 45 1 .� At= 3.188 in2 Ft= 21.600 ksi d T= 68.850 kips *�I 3/s" RA'E Q '" r //1‘ 1= 0.031 in° ,A= 0.375 int r 0.289 in I f k= 1.00 i L 1= 8.500 in y " ' kl/r= 30.0 �- D„ Fa= 20.350 ksi "' — f S= 4.516 in3 Fb= 27.000 ksi RMAX= 15.429 kips t Limiting System Factor Fv= 14.400 ksi VALLow=43.200 kips 1 Results Capacity of System(2 Sides)=15.43(2)=30.86kips(Bracket Only) • 7 of 13 // -.N /1 \\ O II Ii ,0,_�‘ /1 Y 4 ryp `` /1 SECTION A-A ./R's/PIPE/HOLES Q/HOLES Q/HOLES 1/S4.5 �r I 1" N T _ rrYP I — . A Ti K--CAP R1x9x0'-5" I I I I ill i I 3/1 617 O 31/2"0 PIPE , p �Q 0 �� 10 ' l l l I , � ; I I 3/16 V = 3/16 V • I 1 (1-; - 1/S4.6 FSI FOUNDATION BRACKET FS288BL - FRONT SCALE: 3"=1'-0" PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 5FA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f aPortland,Oregon 97223 S 4. 1 p:(503)641-8311 f: (503)643.7905 www.sfadg.com 8 of 13 I 1/S4.5 — i/CAP R/PIPE/HOLES II I II I I II R3/8x10x0'-6" —N— 1/2 3A 617 3 3/16V <TYP I } , , I , 1, / 3/1sV �' 3/1 3/16 V <TYP TYP> 6D I 3/ 16 I I I TYP> 3/ V II i 1 3/16V <TYP 16 II i � 1 I I R/q I . (\ rn 10/8 TYP 4... _ R1/2x7xO'-51/2', 3/16V A& R3/8 w/ 13/16"OI HOLE TYP 1/S4.6 I FSI FOUNDATION BRACKET FS288BL - RIGHT 0 SCALE: 3"=1'–O" PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f aPortland,Oregon 97223 .2 p:(503)641.8311 f: (503)643-7905 J www.sfadg.com 9 of 13 1/$4.5 N Ilir I I I I I I I I I I II f1 0 5)" 0 0 0 I I I I I' , , IIS 'II ' 'i II II II c\ II II I II II t II TYP> 3 I I /16 Itzk: .._ Alk 1/S4.6 I I FSI FOUNDATION BRACKET FS288BL - BACK SCALE: 3"=1'-0" 0 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 SFA Design Group, LIE STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f aPortland,Oregon 97223 ^4. ` p:(503)641-8311 f: (503)643-7905 v` `V� www.sfadg.com 10 of 13 M ' I I 1/S4.5 I I - 111V I I II II I - I _ � I PL3/8 I I i I 1 _- I I I II �r N �» 2 _ _ 4 I 7„ 1 1,-1" 1'-2" 1/S4.6 FSI FOUNDATION BRACKET FS288BL - LEFT (-0 SCALE: 3"=1'-0" PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 5FA Design Group, LLE STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f aPortland,Oregon 97223 S 4.4 p:(503)641-8311 f: (503)643-7905 www.sfadg.com 11 of 13 1/S4.4 1 1W ter' R/HOLES `' s A MM-rn q./HOLE I I M IN `�` I — — — + R/R/HOLE I I co I I N _ I M N<N\NNNN\N\ HT1 T1 u UI— In /HOLE s s , I � IM 3" 4 --- 1'-2" AIL 1/S4.2 NOTE: CAP R NOT SHOWN FOR CLARITY FSI FOUNDATION BRACKET FS288BL - TOP 0 SCALE: 3"=1'-0" PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 5FA Design Group, LLE STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f aPortland,Oregon 97223 S 4.5 p:(503)641-8311 f: (503)643-7905 www.sfadg.com 12 of 13 1/S4.2 _ Zn , Q/HOLE 3" n I • 4/ 0_11 q./HOLE -IT - - - - I I a��/� I I II IT II �/R/HOLE II I I II _I1 - - - - Er-41m i/HOLE U 13/4" TYP M d 1/S4.4 FSI FOUNDATION BRACKET FS288BL - BOTTOM SCALE: 3"=1'-0" PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TEl KT 08/01/2016 SFA Design Group, ILL STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 s f a Portland,Oregon 97223 S4�6 p:(503)641-8311 f: (503)643-7905 V T www.sfadg.com 13 of 13 ...Z./ /— _ /1"/ i . 1111110 / \ DO NOT PLACE HERS VDO NOT PLACE PIERS THIS ZONE W/0 THIS ZONE W/0 DIRECTION FROM \ / DIRECTION FROM ENGINEER 1 / ENGINEER 4 . , ' 7*. 4 a 4 f y NO PIER PLACEMENT ZONE • SCALE: NTS PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS TF16-039 KT 08/01/2016 SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING 9020 SW Washington Square Dr.,Suite 505 %f a �} Portland,Oregon 97223 A . p:(503)641.8311 f: (503)643-7905 www.sfadg.com