Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (44)
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT ! COMMUNITY DEVELOPMENT Permit#: FPS2016-00058 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/01/2016 Parcel: 1 S126DC00900 Jurisdiction: Tigard Site address: 9520 SW GREENBURG RD Project: Greenburg Apartments Subdivision: LEHMANN ACRE TRACT Lot: 5 Project Description: Sprinkler fire protection system for Building 2,a new 4 unit apartment building. Contractor: AFP SYSTEMS INC Owner: RES-OR TIGARD LLC 19435 SW 129TH AVE 730 NW 107TH AVE STE 400 TUALATIN, OR 97062 MIAMI, FL 33172 PHONE: 503-692-9284 PHONE: FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-MF 07/29/2016 $188.28 12%State Surcharge-Building 07/29/2016 $22.59 Type of Use: MF Plan Review-Fire Life Safety-MF 03/29/2016 $75.31 Class of Work: ALT Type of Const: VB Info Process/Archiving-Lg$2.00(over 07/29/2016 $4.00 Occupancy Grp: R-2 Height: ft 11x17) Stories: 3 Info Process/Archiving-Sm$0.50(up to 07/29/2016 $50.00 11x17) Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: .10 Design Area: 0 K Factor: 4.9 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Gales Provided: Cut Sheets Required: Total $340.18 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $10,890.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions t NC by calling 503.232.1987 or 1.800.332.2344. Issued By: m—J Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application �, Fire Protection System t : k . FOR OFFICE USE ONLY t C.0 ��,,.�-^ A• � ` Received � lty of TigardU Date/By: I %�v (37,--- Plan No.: �� �l.t, f C III_ .4 13125 SW Hall Blvd.,Tigard,OR 97223 t" Plan Review 113 J 2, Phone: 503.718.2439 Fax: 503.598.19' --'' ��. Other Permit: ,/�1:. (�— / Date/By f t; %. � T f G A R D Inspection Line: 503.639.4175 a ' Date Ready y 7uds: See Page 2 for Internet: www.ti and-or. ov k ' c+ - .ANotified/Method/ ' /' g gy:77/ 2....<7 Supplemental Information 7, i'`' .7titft-- 7---1-4,./fat TYPE OF : ', R1�QI11RE DATA:1 Al"!II?2 FAMILY DWEI+I�I�' . I ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the 4< ';',i-, -;;;-;,-,-- CATEGORY of CONSTRUCTION r At work indicated on this application. vim,.. ❑ 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ j 111Accessory building ®Multi-family Number of bedrooms: ❑Master builder IIIOther: Number of bathrooms: JOU SITE INFORMATION AND LOCATION Total number of floors: Job site address:9520 SW Greenburg Rd New dwelling area: square feet -1 City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.:Bldg 2 Project name:Greenburg Apartments- Covered porch area: square feet I Cross street/directions to job site:SW Greenburg and SW Lehman St Deck area: square feet Other structure area: square feet i REQUIRE ATA ll RCIAL USE CUE S, 1 Subdivision: Lot no.: Permit fees*are based on the value of the work performed. l Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the _ DESCRIPTION OF'WORK ` work indicated on this application. Install Fire Sprinkler System Valuation: $$10,890.00 Existing building area: square feet New building area: square feet ..: ❑ PROPERTY'"(?WN „:3,,,,,,,," CL`�,AN'I`; � z,, Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: APPLICANT ►t CONTACT PE N \\\' , hs OTIC Business name:AFP Systems Inc All contractors and subcontractors are required to be Contact name:Karmen Carlson licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:19435 SW 129th Ave jurisdiction in which work is being performed.If the City/State/ZIP:Tualatin,OR 97062 applicant is exempt from licensing,the following reasons apply: Phone:(503)692-9284 Fax::(503)692-1186 E-mail:karmen@afpsys.com �!.:. CONTRACTOR Business name:AFP Systems Incl to d Permit fee: Address:19435 SW 129th Ave City/State/ZIP:Tualatin,OR 97062 State surcharge(12%of permit fee): FLS plan review(40%of permit fee): Phone:(503)692-9284 Fax:(503-6) (Due upon application submittal.) CCB lic.:67534 Total permit fees: Amount received: _i___ Authorized signature: (�--._ Cs" This permit application expires if a permit is not obtained Print name:Ka en Carlson Date:3/28/2016 within 180 days after it has been accepted as complete. I * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\FPS-PermitApp_071514.doc 440-46131(11/02/COM/WEB) . City of Tigard: Fire Protection Permit Checklist RECEIVED Page 2- Supplemental Information , ��� MAR Describe work to be done: r 4 ;SID 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Additio .roil., evices� [iNew system Number of sprinkler heads: Number of alarm devices: ❑ Addition or ❑ 1-10 heads: Affidavit required and E 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+ heads: Plan review required and E 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: T e of S stetxt Coxrt late�, �, C ar I3 as Barb e : A.) Commercial Sprinkler [ Wet Dry Additional Standpipes Information: Hazard Group Z. q4 f- 4.,JAt Density .10 ;JO Design Area r/ lie ads t,rf re Area K. Factor y,2 ' 9O,, 9 1/•.z Sprinkler Project Valuation: $ B.) 'Type I- Hood Firepression Systetii Hood Project Valuation: 1 $ C.) Fire Alarm Submittal shall l :tte Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: i $ 1Z) Residential Sprinkler(Stand Alone System) ____^ Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: /b k q° sq.ft. Fire Protection Permit Fees Protect valuation subtotal (see A,B&C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ C,\Users\Karrnen.a fpsysterns\ll esk topV'i'igardPcrmitApp3.doc 2 Seubert Engineering DESIGNING&CONSULTING FROM CONCEPT TO PRODUCTION. 25125 S. Mt. View Rd. Robert C. Seubert, PE Phone/Fax(503)824-5030 Colton, OR 97017 Rseubert©seubertmachining.com Cell (503)805-2920 AFP Systems, Inc. 3/17/16 19435 SW 129th Ave. Tualatin, OR 97062 ATT: Ken Subject: System Review/PE Stamping Greenburg road apartments AFP Project# 16020 Hi Ken I've reviewed all six buildings for this project. Totaling 12 drawings, 23 calculation spread sheets, and 12 seismic bracing calculations. All 23 remote areas for all buildings are designed for light hazard occupancy @ .1 gpm/sq. ft. Attic areas in each building are dry systems, all others are wet. Seismic calculations include 6 lateral and 6 longitudinal. Design criteria is per NFPA#13. I find no concerning issues with the design, layout, or calculations with respect to the applicable NFPA standards the project is adhering to. Given the compliance with the stated and supplied specifications it's my pleasure to approve this packaged with my PE stamp. Best Regards, Robert Seubert, PE City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 9520 SW GREENBURG RD, TIGARD, OR, 97223 Record Type: Record ID: Commercial - Fire Protection System FPS2016-00058 Inspection Type: Inspector: 999 Sprinkler final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor