Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (2)
MEIC2015 - 00211 RECEIVED APR 15 2015 CITY OF TIGARD BUILDING DIVISION MIM HOOD INSTALLATION NOTES CITYOFTIGARD �► .. R _V'lBWED FOR CODE CQ111 P7LIANCE 1. INSTALL OWNER FURNISHED UL LISTED TYPE 1 EXHAUST HOOD. A roveds t,41 2. THE GREASE HOOD SHALL MEET THE REQUIREMENTS OF THE MECHANICAL CODE, OTC: NSF AND NFPA FOR A TYPE i HOOD. GENERAL NOTES °?�����L �• r�r"Iv"#: - T° -vd�! 3. APPROVAL SHALL BE REQUIRED ON FIRE PROTECTION SYSTEM FOR GREASE HOODS AND DUCTS AS REQUIRED BY THE MECHANICAL Address: CODE AND AS REQUIRED BY THE FIRE CODE. • A. CONTRACTORS AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE Suite M. CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK 4. INSTALL OWNER FURNISHED CHEMICAL FIRE SUPPRESSION SYSTEM AS 0 IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY REQUIRED BY NFPA 17A. Br.. Date: DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. r B. COORDINATE WITH THE WORK OF OTHER SECTIONS,EQUIPMENT FURNISHED BY ` \ oo OTHERS,REQUIREMENTS OF THE OWNER,AND WITH THE CONSTRAINTS OF THE �'jj ��j COPY EXISTING CONDITIONS OF THE PROJECT SITE.PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION.NOTIFY GREASE EXHAUST DUCTWORK & HOOD ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. C. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC,SHOWING THE GENERAL SYSTEM SPECIFICATION LOCATION,TYPE,LAYOUT,AND EQUIPMENT REQUIRED.THE DRAWINGS SHALL Q NOT BE SCALED FOR EXACT MEASUREMENT.REFER TO ARCHITECTURAL SEE E CONSTRUCTED SO THAT NO G L S SYSTEM ST S H SE E THE GREASE AXAUYM HAL BE DRAWINGS FOR DIMENSIONS.REFER TO MANUFACTURER'S STANDARD A INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION WILL BECOME POCKETED IN ANY PORTION THEREOF AND SHALL SLOPE AT NOT O REQUIREMENTS. PROVIDE DUCTWORK,CONNECTIONS,ACCESSORIES,OFFSETS, LESS THAN 1/4"PER FOOT IF HORIZONTAL LENGTH UNDER 75 FEET LONG OR 1" j THE ACWAVW4DF A DUCT AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. PER FOOT IF OVER 75 FEET,BACK TO THE HOOD OR AS REQUIRED BY THE LOCAL AUTHORITIES. SMOK11.00 R SHALL W D. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS ACTIVAI M*IBLE AND APPROVED AND AMENDED BY THE GOVERNING CITY.PURCHASE ALL PERMITS B. OPENINGS IN DUCT SHALL CONFORM TO CODE REQUIREMENTS AND SHALL BE ASSOCIATED WITH THE WORK.OBTAIN ALL INSPECTIONS REQUIRED BY CODE. PROVIDED FOR COMPLETE AND THOROUGH CLEANING OF DUCT SYSTEM. AUDIMSSWOVISORY z E. CONTRACT LANDLORD APPROVED ROOFING CONTRACTOR TO PERFORM ROOF C. GREASE HOOD TO EXTEND A MINIMUM OF 6"BEYOND THE COOKING SURFACE ON SIGNALATAO TANW Q U, SEALS FOR MECHANICAL EQUIPMENT ON THE ROOF. ALL OPEN SIDES ORAS REQUIRED BY LOCAL CODE. E W A'i'Ii ENDIElY A`('ION (/) E DMSO .4.1 z F O 8 0 � z z co MECHANICAL NOTES 06 = N O SUPPLY AND RETURN AIR DUCTS DOWN FROM ROOFTOP UNIT.REFER TO ROOF �/� U) � J 15 18"x24"SUPPLY AIR DUCT UP TO MAKE-UP AIR UNIT.REFER TO ROOF PLAN SHEET RTU-i PLAN SHEET MP1.0 FOR CONTINUATION. O V) Q MP1.0 FOR CONTINUATION. I 1 , RTU-2 Q `.J O2 TRANSITION TYPE I EXHAUST FROM HOOD COLLAR TO 10"x18".ROUTE DUCT UP RTU-1 1 RTU-2 10 10"0 s O EF 4 20 14"0 10 A AND BOTTOM TAP TO NEW 14"x14"TYPE I EXHAUST DUCTWORK.EXTEND TYPE I 16 TYPE I EXHAUST DUCT UP TO EF-1. REFER TO ROOF PLAN SHEET MP1.0 FOR E 1; �� —I z EXHAUST DUCTWORK AS SHOWN ON PLANS.REFER TO SHEET MP FOR CONTINUATION.REFER TO SHEET MP FOR GREASE DUCTWORK SPECIFICATION.SEE i EF-3 3�5 ' --- -- - - - - -- T__.._......_.___.._..._........._........_.._.._....__.._.� !_......_.._..0 ._....... ___..._.___......_.._ __...___.. _ .. 400 _. ADDITIONAL INFORMATION.SEE FIREWRAP INSTALLATION DETAIL ON M3.0. DETAIL ON M3.0 FOR FIREWRAP INSTALLATION.MAINTAIN CLEARANCE FOR SERVICING ' 1 RTU-2 (n GREASE DUCT CLEANOUTS. 0 00 �r O PROVIDE VOLUME DAMPER OPERATOR IN GYP BOARD CEILING AREA.THE 17 TYPE I EXHAUST DUCT UP TO EF-2. REFER TO ROOF PLAN SHEET MP1.0 FOR 8 -_ SPECIFICATION SHALL BE LOCKING HAND QUADRANT HANDLE AND AIR-TIGHT END 20"x30" N (� O CONTINUATION.REFER TO SHEET MP FOR GREASE DUCTWORK SPECIFICATION.SEE /ir :, % 2a' O O — LV BEARING WITH VENTFABRICS, INC.NO.677 CONCEALED DAMPER REGULATOR _ % -. z WITH 1/2"ROD NO.680 RIGHT ANGLE GEAR ASSEMBLY AND PLAIN CEILING DETAIL ON M3.0 FOR FIREWRAP INSTALLATION.MAINTAIN CLEARANCE FOR SERVICING j EF-1 c%r GREASE DUCT CLEANOUTS. 16 PRINTABLE COVER PLATE TU n 4 TRANSITION TY 18 10 x10"EXHAUST DUCT UP ROOF. REFER TO ROOF PLAN SHEET MP1.0 FOR ! r cif, _ '`" O PE II EXHAUST DUCT FROM HOOD COLLAR TO DUCT SIZE SHOWN. : -` 5 _ I CONTINUATION.FIELD VERIFY ROUTING OF DUCTS PRIOR TO INSTALLATION.MAINTAIN � " ' EXTEND DUCT UP TO ROOF MOUNTED EXHAUST FAN ABOVE.SLOPE DUCT 1/3" ` I = ` , .-.. . _ •o co 0 CLEARANCES FOR SERVICING INLINE FAN,GREASE DUCT,ETC. HOOD - PER FOOT DOWN TOWARD HOOD.REFER TO ROOF PLAN SHEET MP1.0 FOR f U I EF-2 o CONTINUATION.SEE SHEET MP FOR ADDITIONAL INFORMATION. W—F ROUT MAK P I E E U A R DUCT UP HIGH TO MAINTAIN CLEAR SPACE FOR ACCESS TO �, �O CO INSTALL OWNER FURNISHED GREASE EXHAUST HOOD.SUPPORT HOOD PER GREASE EXHAUST DUCT AND ANY CLEANOUTS.TRANSITION TO 28 x20 . ,_„ r f °aZN a r - MANUFACTURER'S INSTALLATION INSTRUCTIONS.PROVIDE TRAPEZE HANGERS 20 FOR ALL THREAD SUPPORT UNDER DUCTWORK AS REQUIRED.TRANSITION FROM INSTALL OWNER FURNISHED IN-LINE EXHAUST FAN.MAINTAIN CLEARANCE AROUND 1 _.: 19 s F s. -12 fn �- a c ro i HOOD CONNECTIONS TO WELDED KITCHEN EXHAUST DUCT SIZES SHOWN.DO FAN FOR SERVICING. g �J 9 o NOT PENETRATE THE HOOD WITH SCREWS OR RIVETS. �YLO 21 BOTTOM TAP MAKE-UP AIR DUCT PER SIZE SHOWN.MAINTAIN CLEARANCE AROUND r x 1 -2t1"x18" GREASE EXHAUST DUCT CLEANOUTS. a f y y a V o O6 INSTALL OWNER FURNISHED TYPE 11 HOOD.SUPPORT HOOD PER = o # m So Cl) HOOD 2 �.'P ; ' ,o = �m MANUFACTURER'S INSTALLATION INSTRUCTIONS.PROVIDE TRAPEZE HANGERS ' —_-- ` S mom L° FOR ALL THREAD SUPPORT UNDER DUCTWORK AS REQUIRED.TRANSITION TO [ 13 13 2 5 f r rj it - r " i � '- o a H o<O ro V DUCT SIZES SHOWN.DO NOT PENETRATE THE HOOD WITH SCREWS OR RIVETS. I } d tr' O INSTALL(1)7 DAY PROGRAMMABLE THERMOSTAT WITH AUTO CHANGEOVER FOR r B 1 14} 14 I [ n VopU �✓ EACH ROOFTOP UNIT OR THE CORRESPONDING REMOTE TEMPERATURE SENSOR 325 - —s X - - ; i a�'o'' "�m o03 I (S)AS INDICATED BY THE SYMBOL AT THE LOCATIONS SHOWN.ENSURE THERMOSTATS AND TEMPERATURE SENSOR ARE COMPATIBLE WITH ROOFTOP „ 4C> Ak W 3 UNIT.MOUNT THERMOSTAT AND SENSOR AT 48"A.F.F.. - _ _ - - - jL1 p 0 O RTU-1 SHALL BE CONTROLLED BY THE AVERAGE SIGNAL FROM(2)SPACE 14"0 10 A TEMPERATURE SENSORS PROVIDE DUCT T ^r— 9 C MOUNTED SMOKE DETECTOR.DETECTOR SHALL MEET - I I 717 REQUIREMENTS OF U.L.268A. INTERLOCK SMOKE DETECTOR TO SHUT DOWN : Lj ;,;,r rrri rr ,/ •r rrii UNIT UPON DETECTION OF SMOKE.PROVIDE SMOKE DETECTOR WITH AN -' - ANNUNCIATOR WITH PIEZO ALARM AND POWER LED'S FOR VISIBLE AND AUDIBLE - _...- - - •' •_' >- : . .. :........ .. . ..- _.:-,- .:. -•. ... - - �� ALARM SIGNAL,AND VISIBLE TROUBLE SIGNAL.MOUNT ANNUNCIATOR ON ROOM - t1Fy/��)t' ;.,.- '�• ': ..•• -� �> .-•. - � - f _.. .- . a� Ply �• ,=.- I SDE OFCEILING. • .i., � .•: . . . . ,- . : - .:... _ .. .: :, . .. 3 _ ,fes;; lit - %l PROVIDE BOTTOM CONNECTION TAP WITH VOLUME DAMPER IN THE NECK. , , - -.< . ..::-- . .. .. .: ..... . .. . .. .. .. .. .. .. :�- '':- '.•• .• ,': Revisions 10 C �._ I. ,.,. .. 280 25O• .,;,, PROVIDE DUCTWORK,VOLUME DAMPER,AND AIR DEVICE. I � •: � - - ��i. I. ISSUED FOR LANDLORD REVIEW r , - € �o 11 UNDERCUT DOOR 1". 1-21-2015 ,. �_ `� .. �:..-._.,. .. ..,..: -: • . : 'i-: „�` ISSUED FOR PERMIT EXHAUST HOOD UTILITY CABIN 02-04-2015 U. 12 ET, INTEGRAL WITH MAIN HOOD,COORDINATE t LOCATION,CLEARANCES AND ALL REQUIREMENTS WITH ALL TRADES. ;, .::•`""` - ;;' 13 28"x10"DOWN FROM MAKE UP AIR SYSTEM.BALANCE TO 815 CFM � _ ; ,.� 1 •; � ••__"` r 16'0 10 t..: H i j s ! 10 14 16"x8"DOWN FROM ROOFTOP UNIT SYSTEM.BALANCE TO 200 CFM / ' _1# - - i-t =I TU-1 ' ., 30D ., i H 10 16"0 -1250 A X ® A : f 1250 i x,300 Q I 4.21f1` 2"0 1 '0 c t Lj SEQUENCE OF OPERATION - ROOFTOPS I B --- - --- ---- - 0 r II RTU-1 SHALL BE CONTROLLED BY THE AVERAGE SIGNAL FROM(2)SPACE HEATING: r 32 t 4"x16 i 1� 22 18"t, 14"0 TEMPERATURE SENSORS UPON SIGNAL FROM 7-DAY PROGRAMMABLE THERMOSTAT THE FAN SHALL BE DEENERGIZED AND OUTSIDE AIR DAMPER SHALL CLOSE. WHEN SPACE t � OCCUPIED MODE: TEMPERATURE DROPS 2 DEGREES OR MORE BELOW UNOCCUPIED SETPOINT, I �L .?3a r p 114" 14" OUTSIDE AIR DAMPER SHALL REMAIN CLOSED,FAN SHALL BE ACTIVATED AND ' "' �� ( 4 0 f r COOLING: FIRST STAGE OF GAS HEAT SHALL BE ACTIVATED.IF SPACE CONTINUES TO DROP s � "° r UPON SIGNAL FROM 7-DAY PROGRAMMABLE THERMOSTAT DURING AN ADDITIONAL 1 DEGREE,SECOND STAGE OF GAS HEAT SHALL BE ACTIVATED. OCCUPIED TIME,OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM SETPOINT AND WHEN SPACE TEMPERATURE RISES 2 DEGREES ABOVE SETPOINT,GAS HEAT r ' t4 .1 450 i 450 I IL SUPPLY FAN SHALL BE ACTIVATED.IF SPACE TEMPERATURE RISES 2 SHALL BE SHUT OFF.FAN SHALL RUN AN ADDITIONAL 2 MINUTES AFTER GAS HEAT l% rn DEGREES OR MORE ABOVE SETPOINT,FIRST STAGE OF COOLING SHALL BE SHUTS DOWN THEN FAN SHALL SHUT OFF, u7 00 I 1450 ENERGIZED.IF TEMPERATURE CONTINUES TO RISE AN ADDITIONAL 1 D DEGREE OR MORE,SECOND STAGE OF COOLING SHALL BE ACTIVATED. WINTER MORNING WARM-UP: ;� _ 3 i , _ i WHEN TEMPERATURE FALLS 2 DEGREES BELOW SETPOINT COMPRESSORS UPON SIGNAL FROM 7-DAY PROGRAMMABLE THERMOSTAT 1 HOUR PRIOR TO THE "` i SHALL BE DEENERGIZED. SPACE BEING OCCUPIED THE OUTSIDE AIR DAMPER SHALL REMAIN SHUT AND GAS o I o r a 04 HEAT SHALL BE STAGED TO RAISE AND THEN MAINTAIN SPACE TEMPERATURE AT Ott WHEN OUTSIDE AIR ENTHALPY DROPS BELOW THE RETURN AIR ENTHALPY, 70°F. N THE ECONOMIZER SHALL BE ENABLED. IF THE OUTDOOR TEMPERATURE IS FF = ' Signature i 2 ABOVE THE COMPRESSOR LOCKOUT THERMOSTAT SETTING,THE FIRST INTERLOCK WITH EXHAUST FANS: — —— I 02/04/2015 STAGE OF MECHANICAL COOLING SHALL BE ENABLED AS THE SECOND ROOFTOP UNITS SHALL OPERATE IN OCCUPIED MODE WHENEVER EF-1,EF-2 AND Date 0- STAGE OF COOLING. EF-3 ARE ENERGIZED. 06/30/2016 Expiration Date (Qj DUCT MOUNTED SMOKE DETECTORS: HEATING: ROOFTOP UNIT WILL BE DEENERGIZED UPON DETECTION OF SMOKE BY SMOKE I s \ 2 UPON SIGNAL FROM 7-DAY PROGRAMMABLE THERMOSTAT DURING OCCUPIED DETECTOR. i ENGINEER TIME,OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM AND SUPPLY FAN SHALL BE ' I ` I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- OCCUPIEDW ACTIVATED.WHEN SPACE TEMPERATURE FALLS 2 DEGREES OR MORE BELOW COOLING SETPOINT: 75 DEGREES ' PARED UNDER MY SUPERVISION AND THAT TO THE BEST SETPOINT,FIRST STAGE OF GAS HEAT SHALL BE ACTIVATED. IF SPACE OCCUPIED HEATING SETPOINT: 70 DEGREES ] 9AM-10:30PM ' I I OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, ! i REGULATIONS AND ORDINANCES OF PORTLAND,OREGON I TEMPERATURE CONTINUES TO FALL AN ADDITIONAL 1 DEGREE SECOND STAGE I RELATING TO STRUCTURES AND BUILDINGS. OF GAS HEAT SHALL BE ACTIVATED. WHEN TEMPERATURE RISES 2 DEGREES UNOCCUPIED COOLING SETPOINT: 85 DEGREES ! I 10:30PM-9AM �i ABOVE SPACE SETPOINT,GAS HEAT SHALL BE SHUT OFF. UNOCCUPIED HEATING SETPOINT: 55 DEGREES ENGINEER RELATIVE HUMIDITY SETPOINT: 50% COOLING: _ i Drawn By Checked By i UPON SIGNAL FROM 7-DAY PROGRAMMABLE THERMOSTAT THE FAN SHALL BE MECHANICAL CONTRACTOR SHALL PROGRAM THERMOSTATS ACCORDING TO SET CW SK o DEENERGIZED AND OUTSIDE AIR DAMPER SHALL CLOSE. IF SPACE POINTS AND HOURS OF OPERATION. 2I TEMPERATURE RISES 2 DEGREES OR MORE ABOVE UNOCCUPIED SETPOINT, Scale Date rn OUTSIDE AIR DAMPER SHALL REMAIN CLOSED,FAN SHALL BE ACTIVATED AND ANSUL SYSTEM ACTIVATION: 1/4"= 1'-O" 01-06-2015 °) COOLING SHALL BE ENERGIZED.WHEN TEMPERATURE FALLS 2 DEGREES BELOW UPON ACTIVATION OF ANSUL SYSTEM,SHUT DOWN MUA-1,RTU-1,AND RTU-2. SETPOINT COMPRESSOR SHALL BE DEENERGIZED AND FAN SHALL SHUT OFF. PROVIDE RELAYS CONTACTS, INTERLOCKS,TRANSFORMERS,AND ALL ASSOCIATED Job No. 3: WIRING TO ACCOMPLISH SEQUENCE.MUAO IS ALREADY PREWIRED TO SHUT DOWN MECHANICAL PLAN 14-2115 � IN HOOD CONTROL PANEL.MECHANICAL CONTRACTOR SHALL INTERLOCK RTU-1 NORTH AND RTU-2 TO ALSO SHUT DOWN. 01 1/4"=V-0" PLAN Sheet No. M1 . 0 MECHANICAL SYMBOLS LEGEND ABBREVIATIONS: GENERAL REFERENCES/NOTATIONS: AFF/AFG ABOVE FINISHED FLOOR/GRADE BTU BRITISH THERMAL UNIT O TAGGED NOTE DESIGNATION r CD CONDENSATE PIPING PE MECHANICAL EQUIPMENT DESIGNATION CFM CUBIC FEET PER MINUTE = `% ROOFTOP UNIT SCHEDULE DB DRY BULB MARK(RTU-#) 1 2 MANUFACTURER LENNOX LENNOX EAT ENTERING AIR TEMPERATURE DIFFUSER DESIGNATION AND CFM MODEL LGH150S413 LGH0901-1413 CFM NOMINAL TON 12.5 7.5 ESP EXTERNAL STATIC PRESSURE AIR FLOW(CFM) 5,000 3,000 OA FLOW(CFM) 1,200 850 LAT LEAVING AIR TEMPERATURE DOUBLE LINE DUCT SYMBOLS: AMBIENT OAT("F) 95 95 EXTERNAL STATIC(IN.W.C.) 1.50 1.50 NC NOISE CRITERIA DX COOLING COIL NEW SHEET METAL DUCTWORK&SIZE REFRIGERANT R-410A R-410A TYP TYPICAL 00 AMOUNT(LB-OZ) 14-0 15-0 ARI EER 11.0 12.5 WB WET BULB ® SUPPLY OR OUTSIDE AIR DUCT ARI NET CAPACITY(BTU/H) 138,000 93,000 W EAT(°F DB/WB) 80/67 80/67 MUA MAKE-UP AIR TOTAL(BTU/HR) 142,600, 90,000 ® RETURN AIR DUCT SENSIBLE(BTU/HR) 109,800 69,153 SA SUPPLY AIR GAS HEAT . ... w GRILLES/DIFFUSERS: ® Q W FUEL NATURAL GAS NATURAL GAS EXHAUST AIR DUCT ' )n INPUT(BTU/HR) 180,000 180,000 SUPPLY DIFFUSER VO OUTPUT(BTU/HR) 144,000 144.000 clf Z) DUCTWORK TRANSITION W Q ELECTRICAL ,�, SIDEWALL MOUNTED SUPPLY REGISTER VOLTS/fd/HZ 208/3/60 208/3!600 W MOTOR HP 5 3 UNIT MCA 70 48 RETURN GRILLE SUPPLY DUCT ELBOW UP OR DOWN Z Q MOCP AMPS 80 60 pi APPROX.WEIGHT(LBS) 1,500 1,500 W ACCESSORIES 1 THRU 8 1 THRU 8 EXHAUST GRILLE RETURN DUCT ELBOW UP OR DOWN n w NOTES 1 -3 1 -3 C Z ACCESSORIES EQUIPMENT: EXHAUST DUCT ELBOW UP OR DOWN G O Z 1) FACTORY FURNISHED 14"HIGH SEISMIC ROOF CURB ` II--- ----11 O I-_ Q 2) FACTORY PROVIDED 5 MINUTE DELAY ON COMPRESSOR RESTART. ® ROOF MOUNTED EXHAUST FAN U c-9 W M 3) FACTORY PROVIDED SINGLE ENTHALPY OUTSIDE AIR ECONOMIZER. DUCT ELBOW WITH FIXED TURNING VANES z J 4) FACTORY PROVIDED POWER EXHAUST FAN. Fo® -1p6 = (NQ 5) FACTORY PROVIDED DISCONNECT SWITCH MOUNTED AND WIRED. I ROOFTOP UNIT DUCT BRANCH TAKE-OFF '^ a 6) FACTORY FURNISHED ER. 7 DAY PROGRAMMABLE THERMOSTAT WITH L -1 W W PROVIDE RTU-1 WITH(2)REMOTE SENSORS THE -ELECTRIC ROUND SPIN-IN WITH DAMPER 0 PROVIDE RTU-2 WITH(1)REMOTE SENSORS 7) FACTORY PROVIDED HAIL GUARD. Q TEMPERATURE SENSOR `1-`� FLEXIBLE DUCTWORK (MAX 6-0"LENGTH) 0 M W0 Q Uj 8) FACTORY PROVIDED HORIZONTAL BAROMETRIC RELIEF DAMPER AND HORIZONTAL DISCHARGE KIT. QH HUMIDITY SENSOR 7 NO C� 0 NOTES Z r �- Z 1) SET MINIMUM OUTSIDE AIR AS SPECIFIED ABOVE.OUTSIDE AIR ® DUCT SMOKE DETECTOR DAMPER SHALL FULLY CLOSE ON UNIT SHUTDOWN. 2) ELECTRICAL CONTRACTOR TO PROVIDE AND POWER GFI L- VOLUME DAMPER CONVENIENCE OUTLET.OUTLET TO BE MOUNTED ON UNIT ON A NON-REMOVABLE PANEL AND NOT ON THE UNIT NAMEPLATE. �0 c9,O ��� U�oa 3) RTU-1 THERMOSTAT SHALL AVERAGE SIGNAL FROM(2)REMOTE SYMBOLS LEGEND NOTES: 1. REFER TO SPECIFICATIONS AND PLAN NOTES FOR DETAILED DESCRIPTION OF ALL DEVICES SHOWN __ c ,o SENSORS .0 CO IN THIS SCHEDULE,PROVIDED BY THIS CONTRACTOR. N a W N - 0 n S C co 0 W Q) C 0 V O �Q E °7wa -00 ftm 0-0 Cd ao ,> 0 O°� V10 x c ty6N A._d�o, dm io yo �Uctl � GRILLE, REGISTER, AND DIFFUSER SCHEDULE EXHAUST AND VENTILATION FAN SCHEDULE a" � mo0 MARK A B C MARK(EF-#) 1 2 3 4 C OOD MANUFACTURER TITUS TITUS TITUS MANUFACTURER CAPTIVE AIRE CAPTIVE AIRE CAPTIVE AIRE CAPTIVE AIRE '- L W 0 3 to MODEL TDC PAR-AA TDC MODEL USBI15BD-RM USBI15BD-RM SIBD100A-CA SIDD09OA-CA t o TYPE LOUVERED FACE PERFORATED LOUVERED FACE UTILITY(UPBLAST UTILITY(UPBLAST C9 TYPE INLINE INLINE DIFFUSER CEILING DIFFUSER DIFFUSER POSITION) POSITION) m NECK SIZE(L"XW") SEE PLAN SEE PLAN SEE PLAN DRIVE TYPE BELT BELT BELT BELT FACE SIZE(L"XW") 24"x 24" 24"x 24" 12"x 12" PERFORMANCE FRAME TYPE LAY-IN LAY-IN LAY-IN AIR FLOW(CFM) 2040 2040 800 350 FINISH BLACK WHITE WHITE EXT.STATIC(IN W.C.) 1.5 1.5 0.5 0.5 NOISE CRITERIA LEVEL <30 <30 <30 FAN SPEED(RPM) 1544 1544 1230 1259 (1)WIRE OF EACH PAIR ACCESSORIES OBD,STR STR TRM,OBD,STR ELECTRICAL _ 10kO REMOTE USED(TYPICAL) NOTES - 2 1 VOLTS/O/HZ 208/3/60 208/3/60 115/1/60 115/1/60 SENSOR MAKE-UP AIR UNIT SCHEDULE MARK D E F FAN MOTOR HP 1.5 1.5 0.25 0.125 18-2 WIRING SEE DETAIL 02a FOR RTU-1 MARK(MUA-#) 1 MANUFACTURER TITUS TITUS TITUS ACCESSORIES WP,RC,GDC,HK WP,RC,GDC,FAP,HK WP,BD,BS,SI WP,BD,BS,SI Revisions SEE DETAIL 02b FOR RTU-2 APPROX.WEIGHT(LBS) 300 300 150 110 � MANUFACTURER CAPTIVE AIRE MODEL 355FL PAR 355FL ISSUED FOR LANDLORD REVIEW WHT f T }- - - �( T ) W2 - a MODEL A2-D.750-G15 TYPE 1!2"BLADE SPACING, PERFORATED 112"BLADE SPACING, SERVES HOOD 1 HOOD 2 HOOD 3 RESTROOMS 01-21-2015 �J 1/7 8 ( H1 H2 H3 CONFIGURATION DOWNFLOW 35°DEFLECTION CEILING DIFFUSER 35°DEFLECTION NOTES 1-2,4 - 1-2,4 1-3 1,3 ISSUED FOR PERMIT n /- T W1 - b DRIVE TYPE BELT NECK SIZE(L"XW") 22"x 22" SEE PLAN 10"x 10" ACCESSORIES �02-04-2015 PERFORMANCE �..,,.� _h�,.�,.. ��?? FACE SIZE(L"XW") 24"x 24" 16"x 16 12"x 12" BS-BIRD SCREEN;BD BACKDRAFT DAMPER;GDC GREASE DRAIN AND CUP;RC ROOF CURB; DISCONNECT AIR FLOW(CFM) 3264 FRAME TYPE LAY-IN LAY-IN LAY-IN WP-NEMA 3R DISCONNECT SWITCH;FAP-FAN ADAPTER PLATE;HK-HINGE KIT;SPRING ISOLATORS Q C 18-2 SWITCH EXTERNAL STATIC(IN W.C.) 1.0 FINISH WHITE WHITE WHITE NOTES 18-2 FAN SPEED(RPM) 1017 NOISE CRITERIA LEVEL <30 <30 <30 1) FAN FURNISHED WITH UNIT MOUNTED NEMA 3R DISCONNECT. Q a - d DIRECT FIRED HEATER ACCESSORIES STR TRM,STR TRM,STR 2) EF-1, EF-2,AND EF-3 MOTOR STARTERS WITH CONTACTORS ARE PROVIDED WITH HOOD CONTROL PANEL. FUEL NATURAL GAS NOTES - 2 - 3) EXHAUST FAN MOTORS SHALL HAVE INTEGRAL OVERLOAD PROTECTION. - e a - - - - W2 INPUT(CFH) 268,215 MARK � G _H 1 4) FURNISH WITH GREASE GUARD SYSTEM. HEAT OUTPUT(CFH) 246.758 MANUFACTURER TITUS TITUS TITUS CONTROL NOTES: WHT ( T J I ( G r - - f b - - - - W1 HUM - - V OUT ELECTRICAL MODEL 355FL 355FL TDC A) EXHAUST AND MAKEUP AIR SYSTEMS(EF-1, EF-2, EF-3, MUA-1)SHALL BE ENABLED BY A SWITCH(ON/AUTO/OFF)ON THE v ���/// VOLTS/O/HZ 208/3/60 TYPE 1/2"BLADE SPACING, 1/2"BLADE SPACING, LOUVERED FACE MAIN COOKLINE HOOD. C - - - Y2 �- - - -0 GRD FAN MOTOR HP 3 35°DEFLECTION 35°DEFLECTION DIFFUSER EF-1 AND EF-2 SHALL OPERATE DURING BUSINESS HOURS.DURING NON-BUSINESS HOURS,FANS SHALL OPERATE VIA Q APPROX.WEIGHT(LBS) 1000 TEMPERATURE SENSORS IN THE EXHAUST DUCT. t NECK SIZE(L"XW") 22"x 22" 22"x 22" SEE PLAN - - - - ACCESSORIES ALLEF-3 SHALL OPERATE DURING BUSINESS HOURS,AND BE OFF DURING NON-BUSINESS HOURS `- RC d � Y1 /� - VIN FACE SIZE(L"XW") 24"x 24" 24"x 24" 24"x'24" NOTES ALL MUA-1 SHALL BE INTERLOCKED TO OPERATE WHILE EF-1,EF-2 AND EF-3 OPERATE. d - - - FRAME TYPE LAY-IN LAY-IN LAY-IN 0- 10kQ REMOTE e - / ACCESSORIES FINISH WHITE BLACK WHITE RTU-1 AND RTU-2 SHALL BE INTERLOCKED TO OPERATE WITH EF-1,EF-2 AND EF-3. RTU-1 AND RTU-2 SHALL OPERATE IN SENSOR I 1) FACTROY POWERED NEMA 3R DISCONNECT SWITCH NOISE CRITERIA LEVEL <30 <30 <30 OCCUPIED MODE WHILE EF-1,EF-2 AND EF-3 ARE IN OPERATION. h f - - - -{ G ) / MOUNTED AND WIRED. ACCESSORIES TRM,STR STR OBD,STR,TRM B) ELECTRICAL CONTRACTOR TO INTERLOCK EF-4 TO OPERATE WITH ALL TOILET ROOM LIGHT FIXTURES. THERMOSTAT SET �J I `J / 2) FACTORY PROVIDED REMOVEABLE ACCESS NOTES TO 20kf) _ - - - LIDPANELS. CD 9 r R 3) FACTORY PROVIDED MOTORIZED INTAKE DAMPER. ACCESSORIES N 02 a RTU-1 I I 4) FACTORY PROVIDED WEATHER HOOD AND OBD-OPPOSED BLADE DAMPER;ASD-AIR SCOOP DAMPER; N I BIRDSCREEN ON INLET. TRM-RAPID MOUNT FRAME;STR-SQUARE TO ROUND. OCP NOTES NOTES AIR BALANCE SCHEDULE C 1) MOTOR STARTER IS PROVIDED WITH HOOD 1) PROVIDE WITH A 2-WAY OR 3-WAY THROW ID INDICATED ON MECHANICAL PLAN. W EQUIPMENT RTU-1 RTU-2 EF-1 EF-2 EF-3 EF-4 MUA-1 TOTALS -I CONTROL PANEL. 2) RETURN GRILLE USED AS SUPPLY DIFFUSER.GRILLE SHALL BE WITHOUT PATTERN Ip h I 2) UNIT IS WIRED WITH EF-1,EF-2 AND EF-3. OUTSIDEAIRFLOW(CFM) 1,200 850 3,264 5,314 U WHT ( T }- - - 1 T ) W2 - a I RTU TERMINAL STRIP CONTROLLER. �J �J RETURN AIRFLOW(CFM) 3,800 2,150 5,950 RTU-1 SUPPLY AIRFLOW(CFM) 5,000 3,000 3,264 11,264 _ _ RTU-2 EXHAUST AIRFLOW(CFM) 2,040 2,040 800 350 5,230 0 T - - T W1 b I Signature ZQ � ( I I BUILDING PRESSURE(CFM) 1,200 850 -2,040 -2,040 -800 -350 3,264 84 02/04/2015 YZ - C I 12011160 (CFM) Date -� � 18-2 WIRING RESULTING BUILDING PRESSURIZATION CFM 84 06/3012016 � 18 2 Y1 I d I Expiration Date W � 20M)REMOTE I ( 1 ENGINEER co SENSOR C - e L -- - - - - - - - - O G I - f I- I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- PARED UNDER MY SUPERVISION AND THAT TO THE BEST ANSUL SYSTEM R2-1 RTU-1 OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, C) ( SPARE RELAY REGULATIONS AND ORDINANCES OF PORTLAND,OREGON / g CONTACTS R2-2 RTU-2 RELATING TO STRUCTURES AND BUILDINGS. CA00 I RC RETURN AIR SMOKE DETECTOR FURNISHED ENGINEER AND INSTALLED BY HVAC CONTRACTOR Drawn By Checked By h NOTE: CW SK THERMOSTAT SET A - - i TO 20kf2 CONTRACTOR IS RESPONSIBLE TO VERIFY Stele Date 1/4"= 1'-0" 01-06-2015 °' 02 b RTU-2 PRIOR TO INSTALLATION.CURRENT WIRING REMENTS WITH LENNOX Job No. HVAC SENSOR / THERMOSTAT WIRING DIAGRAM 14-2115 02 NOT TO SCALE Sheet No. M2 . 0 DISCHARGE;MIN 10 FT FROM ANY OUTSIDE AIR WRAPPED INSULATION COVERING RIGID ROUND DUCT FLEXIBLE DUCT CONNECTION INTAKES EXHAUST FAN;SEE 3.73xH - - A° A° RIGID ROUND SHEET METAL DUCT SCHEDULE FAN SHALL BE CONNECTED TO EXHAUST DUCT BY 20° >300* FLANGES SECURELY BOLTED OR BY A SYSTEM _ FOB FOT 1"X 20 GAUGE GALVANIZED SUPPORT STRAP MINIMUM 40", SPECIFICALLY LISTED FOR SUCH USE. H A° A° BALANCING DAMPER 20°PROVIDE DUCTINSULATED �r EXTENSION AS SEE PLAN FOR DUCT SIZE REQUIRED. ELEVATION ACCESS DOOR ACCESS DOOR PLAN SUPPLY DUCT MOTOR WITH TRANSITION W/ FOB FOT WEATHER COVER DN EQUIPMENT A° A. SQUARE TO ROUND -� BALANCING HANDLE. LOCK INTO INSULATED FLEXIBLE DUCT ADAPTOR(IF REQUIRED) PLAN POSITION AND MARK PERMANENTLY. INSULATE BACKPAN OF __ FLAT ON BOTTOM A°/2 PROTECTION SADDLE VIBRATION TRANSITION MINIMUM(3)DUCT DIFFUSER DIAMETERS - FOB FOT DIFFUSER STARTER COLLAR(MINIMUM 4"). ISOLATOR DUCT OFFSET �12 ,; r ROOF-\ F? NOTES: 1) PROVIDE AT FLEXIBLE DUCT CONNECTION METAL OR"PANDUIT"DRAWBAND ON THE INTERIOR LPLAN VIEW PLAN VIEW PLAN VIEW FLEXIBLE DUCT HELIX. SECURE THE INSULATION OVER THE DRAW BAND WITH AN ADDITIONAL CEILING DRAWBAND. r _ 2) PROVIDE BEADING ON ROUND METAL DUCT 12"OR LARGER IN DIAMETER. L SUPPLY DIFFUSER WITH co EQUIPMENT SUPPORTS 3) PROVIDE MINIMUM 4"COLLARS FOR ATTACHMENT OF THE FLEXIBLE DUCT TO ROUND DUCT, LAY-IN FRAME(SURFACE JA'/:2 DAMPERS AND DIFFUSERS. MOUNT FRAME SIMILAR) A° 4) BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION45° FOT OVERLAP. W NOTE: GREASE DUCT;ALL W 1/2 W FOB 5) BALANCING DAMPERS SHALL BE INSTALLED AT ALL BRANCH DUCTS,AND ALL TAKE-OFFS 1. FLEXIBLE CONNECTORS SHALL NOT BE USED. WELDED CONSTRUCTION (4"MIN.) A° FROM MAIN DUCT. O 2. EXHAUST FAN SHALL HAVE A DRAIN DIRECTLY CONNECTED TO A READILY EED 1 GAL. 3. FINALACCES INSTALLATION HEIGHT SIBLE AND VISIBLE ROF FAN SHALLEASE A ELDE ERMINEDE NOT TO CBY DUCTWORK BRANCH DUCT ELEVATION ELEVATION ELEVATION Q HEPAR ELEVATION. TFORLDUCTWOLENGALL THS DIFFUSER CONNECTION DETAIL- FLEX DUCT � 1/4"PER FOOT FOR LENGTHS UNDER 75' 1"PER FOOT FOR LENGTHS 75'AND GREATER. NOTES: 1) ANGLE A=30°WHEN AIR FLOWS IN DIRECTION OF ARROW(SUPPLY AIR). 01 NOT TO SCALE W 2) ANGLE A=20°WHEN AIR FLOWS IN OPPOSITE DIRECTION OF ARROW(RETURN OR EXHAUST). �.. Q 08KITCHEN EXHAUST FAN DETAIL NOT TO SCALE LOW VELOCITY DUCT FITTINGS DETAIL Q a 05 NOT TO SCALE /�I. - Cl) J GASKET -HVAC EQUIPMENT Q CO, 0 z 1.THERMAL CERAMICS FIREMASTER INSTALL UL LISTED FASTWRAP XL OR PYROSCAT XL IS TESTED FIRESTOP SYSTEM WITH EQUAL F AND T-RATING AT LAG BOLT LAG BOLT = N W -18 GAUGE TIE DOWN Q TO ASTM E2336 AND UL LISTED PER PENETRATIONS OF RATED ASSEMBLIES RESTRAINT rr�� HNKT.G18 TO PROVIDE ZERO CLEARANCE COUNTERFLASHING V J � � TO COMBUSTIBLES AND TO PROVIDE A 1- 1/2 IN.(13MM)STEEL BANDING OR 2-HOUR ENCLOSURE. THROUGH PLACED 1-1/2 IN.(38MM) - .. W O Q PENETRATIONS FIRESTOP SYSTEMS ARE FROM TRANSVERSE JOINTS MIN. 1-1/2"GALVANIZED STEEL ANGLE IRON ROOFING TESTED IN ACCORDANCE WITH ASTM E 814 TREATED WOOD NAILER �h -, AND MAXIMUM 12 IN(305 MM)O.C. CROSS BRACE BOLTED TO UPRIGHTS. (UL 1479). ICC-ES APPROVAL PER REPORT R ��R SECURED TO CURB CANT STRIP Q U) Q ESR 2213 OR ESR 2832. . ALLOW MINIMUM 1/8"SPACE AT SIDES AND 1/2" '=' SPACE AT TOP BETWEEN DUCTWORK AND ANGLE ROOF CURB O 00 w Q 2.COMPLIANT TO THE FOLLOWING CODES: '' �' MIN. 1-1/2"GALVANIZED STEEL ANGLE IRON IRON. : ROOFING r I- NFPA 96 1� f ` WELDED TO BASE PLATE. INSULATION z (VO (' O INTERNATIONAL MECHANICAL CODES ,F UNIFORM MECHANICAL CODE. _= ROOF INSULATION CALIFORNIA MECHANICAL CODE - 18 GAUGE GALVANIZED STEEL DUCTWORK COUNTERFLASHING. - ROOF STRUCTURE 3.INSULATION APPLIED IN TWO LAYERS WITH , = 4x4 GALVANIZED STEEL BASE PLATE,FASTEN TO FRAME OPENING WITH TIGHT COMPRESSION JOINT ON BOTH ", ° LAYERS AT ALL JOINTS. STEEL CHANNEL -- EQUIPMENT SUPPORT WITH(4)SCREWS. o 4.MINIMUM 16 GAUGE CARBON STEEL(OR 18 j NOTE: 318"THROUGH BOLT,WASHERS, ;_' o CO 1. CURB SHALL BE TAPERED TYPE AND LOCKWASHERS,AND NUT,2 MINIMUM D OR ROUND GREASE EXHAUST DUCT MATCH THE PITCH OF THE ROOF. GAGE STAINLESS STEEL)RECTANGULAR ' SECURELY INSTALL BASE PLATE TO CURB. EACH CHANNEL �� d&n o ��` 2. SECURELY INSTALL CURB TO ROOF;USE OD co CD 5.INSTALL UL LISTED AND LIQUID TIGHT FASTENERS AS REQUIRED BY ROOF NOTE: 1. CUT AND PATCH EXISTING ROOFING AS REQUIRED FOR NEW CURB INSTALLATION. THERMAL CERAMICS FASTDOOR XL FASTDOOR XL-UL CONSTRUCTION. FACTORY INSTALLED WOOD NAILER. 2. CURB SHALL BE TAPERED TYPE AND MATCH THE PITCH OF THE ROOF. - U) ACCESS DOORS AT ALL CHANGES IN LISTED DUCT ACCESS 3. IF REQUIRED BY ROOFING SYSTEM, A C) U'_ .o . 0) 3. CONTRACTOR TO PROVIDE TREATED WOOD BLOCKINGS AND SHIM FLAT ROOF CURB V �E DIRECTION AND AT MINIMUM EVERY 20 FT AND 2-HOUR RATED FIBER CANT SHALL BE ADDED AT CURB 4) �' m a _ �M 0 ON HORIZONTAL RUNS. INSULATION COVER BASE WHERE IT MEETS THE ROOF. TILL LEVEL FOR ALL ROOFTOP UNITS AND TO ACHIEVE ROOF CURB HEIGHTS. PROVIDE .,. .. tom 4. PROVIDE SUPPORTS AT EACH ROOF CURB EXTENSION IF REQUIRED. o o, u `'=m X m 6.SUPPORT HANGER SYSTEMS DO NOT NEED TRAVERSE JOINT OF DUCTWORK AND S„ h w L_Jt�5 TO BE WRAPPED PROVIDED THE HANGER MAXIMUM 5'-0"ON CENTER. MINIMUM 8"HIGH. V c r. y Q) m m m ROOFTOP UNIT CURB DETAIL RODS ARE MINIMUM OF 3/8 IN.DIAMETER 5. CUT AND PATCH EXISTING ROOFING AS ROOFING MATERIAL. �(N c F C Uovov AND SUPPORTS ARE MINIMUM 2 X 2 X 1/8 IN. 1 1/2' (3d) REQUIRED FOR NEW CURB 02 NOT TO SCALE m o00 thr-oro3 STEEL ANGLE OR SMACNA EQUIVALENT M, ;,, INSTALLATION. 6' +j 2F \J SUPPORT SYSTEM. `� `A. "� ` '-� ROOF INSULATION. ,o 7.THERMAL CERAMICS DUCT WRAP SHALL BE m �� _ �`� INSTALLED DIRECTLY ONTO THE DUCT AND UL LISTED-FASTDOOR XL = REINFORCED INSULATED SLOPE TOP @ 1/4"PER FOOT m APPLIED FROM THE HOOD CONNECTION TO SHEET METAL. CAULK ALL THE CONNECTION TO THE FAN. ZTIGHT COMPRESSION JOINT ` r r JOINTS,AND POSITION TO DEKTITE NEOPRENE COLLAR. ON BOTH LAYERS r ® rr rr rrr ®r rr rr ®r rr SHED WATER SECURE IN PLACE WITH SCREWS 8.THERMAL CERAMICS DUCT ENCLOSURE P rrr ®® rr rrr r{r rrr rrr rrr ® s r rrr TO HOOD AND METAL BANDS SYSTEM SHALL BE INSTALLED IN STRICT COUNTERFLASHING WITH AROUND THE PIPES. SEAL ACCORDANCE WITH MANUFACTURERS FIREWRAP INSTALLATION DETAIL FASTENERS @ 24"O.C. WATER TIGHT. INSTRUCTIONS AND UL LISTINGS. ROOFING CONSTRUCTION. 30°ANGLE BASE FLASHING W/ ®g NOT TO SCALE FASTENERS @ 8"O.C. WOOD BLOCKING Revisions 06NOT TYPICAL DUCT ROOF SUPPORT DETAIL TO SCALE CANT STRIP ISSUED FOR LANDLORD REVIEW A01-21-2015 � Pr ISSUED FOR PERMIT 02-04-2015 ROOF STRUCTURE ROOF INSULATION Q PIPE ROOF PENETRATION 0 03 NOT TO SCALE 0 0 UP TO EXHAUST FAN SEE PLANS FOR DUCTWORK SIZE AND ROUTING r 6" MAX FROM CHANGE EVERY 12' IF DUCT OF DIRECTION GREATER THAN n_ 16'TOTAL FROM N INLET TO FAN WELD DRIP SHIELD ALL AROUND tom' WELD 1"COLLAR ALL AROUND LO N ROOF CURB, SEE TYPICAL DETAIL FOR MANUFACTURER -- N 0 0 0 FASTEN COUNTERFLASHING TO MODEL AND INSTALLATION CURB WOOD NAILER WITH SCREWS, Signature QDIRECTIONS. 6" ON CENTER 02/04/2015 Date W Q 06/30/2016 Expiration Date zz8' FROM CORNERS NOTES: ENGINEER LU ELEVATION VIEW 1. ACCESS PANEL SHALL BE "FLAME GARD" MODEL ACC-10X6 IHEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- ROOF CONSTRUCTION - O ( OR APPROVED EQUAL) DUCT RISER, SEE DRAWINGS FOR PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, C:) OORDINATE WITH GENERAL CONTRACTOR:f 2. INSTALL ACCESS PANELS IN TYPE 1 ( FASTEN DUCTWORK TO MOUNTING MAIN HOOD SYSTEM ) D REGULATIONS AND ORDINANCES OF PORTLAND,OREGON RELATING TO STRUCTURES AND BUILDINGS. AND TYPE 2 ( PASTA AND DISH SYSTEM ) EXHAUST FLANGE WITH SOLID POP RIVETS 6" FLANGED CONNECTION WITH 1. ACCESS PANEL SHALL BE SIDE MOUNTED AND ACCESSIBLE DUCTWORK. ON CENTER NEOPRENE GASKET, FASTEN WITH °' 2. FROM THE NOODLES SPACE. 3. INSTALL ONE ACCESS PANEL AT EACH CHANGE OF SCREWS, 6" ON CENTER ENGINEER 00 3. DO NOT LOCATE ABOVE ELECTRICAL ITEMS ( LIGHTS, DIRECTION. NOTE: tm SPEAKERS, ALARM SENSORS ) 4. INSTALL ONE ACCESS PANEL 8' FROM EACH CORNER. COUNTERFLASHING DRIP SHIELD AND EXPOSED DUCTWORK SHALL BE MINIMUM 18 GAUGE, Drawn By Checked By o DO NOT LOCATE WITHIN 3' OF STRUCTURAL BEAM. 5. INSTALL ONE ACCESS PANEL EVERY 12' ON ANY GALVANIZED STEEL AIR-TIGHT CONSTRUCTION. CW SK HORIZONTAL RUN AFTER THE FIRST PANEL THAT WAS Scale Date Cn EXHAST DUCT ACCESS INSTALLED AT 8' IF DUCT RUN IS LONGER THAN 16' DUCT THRU ROOF DETAIL AS SHOWN 01-06-2015 6. INSTALLATION ON DUCTWORK SHALL CONFORM TO ALL PANEL INSTALLATION MANUFACTURER'S SPECIFICATIONS AND REQUIREMENTS. 04NOT TO SCALE Job No. 07 NOT TO SCALE 14-2115 v Sheet No. M3 . 0 SUPPORT STRUCTURE SUPPORT STRUCTURE SCB ATTACHED TO TOP OF JOIST WITH JAH The JAH is used to attach solid or cable ROD COUPLING braces to the top cord of bar joists.Attachment71 ,� ROD COUPLING MASON TYPE SRC OR UR SEISMIC ROD CLAMP IF REQUIRED. ` to the lower cord is not recommended. �, MASON TYPE SRC OR UR to TYPE SSB MASON TYPE SSB SEISMIC BRACKET SEISMIC BRACKET 1 SEISMIC ROD CLAMP IF 1 THREADED ROD REQUIRED. i£ "E"TAPPED HOLE 1 THREADED ROD 1 ROD STIFFNER ANGLE OR STRUT IF REQUIRED. IN DUCTILE IRON CASTING.BOLTA _ ROD STIFFNER ANGLE OR BY OTHERS. STRUT IF REQUIRED. BOLT LENGTH IS i ANGLE LEG LENGTH PLUS 1 1/2"(40mm) � DUCT ROD COUPLING FOR DUCT I OD COUPLING FOR 00 MINIMUM ADDITIONAL UPPER SUPPORT T LOWER ROD ATTACHMENT. LOWER ROD ATTACHMENT. ® STIFFEN DUCT -- ADDITIONAL UPPER SUPPORT T `hl• STRUCTURAL TRAPEZE SUPPORT STIFFEN DUCT PEZE SUPPORT W STEEL BEAM l� SCBV-SEISMIC CABLE AIRCRAFT CABEL O BRACE VISE REF. PAGE X3 B � STEEL BRACE UM �/� Q MASON TYPE SCBH g�_g i 10 SELF-TAPPING V) O SEISMIC BRACKET NO.10 SELF-TAPPING SHEET METAL SCREWS SHEET METAL SCREWS ' MAXIMUM 12 IN.O.C.TOP MASON TYPE SSB MAXIMUM 121N.O.C.TOP W 1 IN. AND BOTTOM SEISMIC BRACKET IN AND BOTTOM D NEOPRENE FRICTION C (n MAXIMUM SCB/SSB LOADS WASHERS TO STRUCTURE UP TO 1:1 BRACE ANGLE 3; Z SCB orSS6 O SCBV TENSION* SHEAR LONGITUDINAL SEISMIC CABLE BRACE LONGITUDINAL SEISMIC SOLID BRACE O Q SIZE lbs(kN) Lbs(kN) U (� TYPE JAH DIMENSIONS inches mm O� FOR RECTANGULAR DUCT O FOR RECTANGULAR DUCT LU = CV 1 690(3.1) 690(3.1) 04 Max. Load tbs (kgs) NOT TO SCALE NOT TO SCALE r^ Q � Q 2 1450(6.5) 1450(6.5) Size SCB/SSB Size A B C D E SCB SSB V, U) ti 3 2230(10.0) 2230(10.0) JAH-0 SCB-0 3 (76) 3/4 (19) 17/8 (48) 13/4(44) 3/8-16UNC 500(227) - - n=U=UP T01.5:1 OR 2:1 BRACE ANGLE, JAH-1 SCB/SSB-1 3 (76) 3/4 (19) 17/8 (48) 21/4 (57) 1/2-13UNC 975 (442) 1500 (680) J > O Q JAH-2 SCB/SSB-2 3 (76) 3/4 (19) 21/8 (54) 3 (76) 5/8-11 UNC 2050 (930) 3000 (1361) MULTIPLY BY 1.2 OR 1.3 RESPECTIVELY. ___ Q 07 Q U) JAH-3 SCB/SSB-3 3 76 3/409) 21/2 (64) 33/4 (95) 3/4-10UNC 3150 1429 5000 (2268)_j �� SUPPORT STRUCTURE MASON TYPE SSB SUPPORT STRUCTURE SEISMIC BRACKET O 00 �-- LUo JOIST ATTACHEMENT HARDWARE 04 O � d � � a�� � Z o 05 NOT TO SCALE ROD COUPLING P: Z ROD COUPLING MASON TYPE SRC OR UR MASON TYPE SSB SEISMIC ROD CLAMP IF SEISMIC BRACKET MASON TYPE SRC OR UR REQUIRED. SEISMIC ROD CLAMP IF THREADED ROD "o��o 1 REQUIRED. V v o o. THREADED ROD 1 ROD STIFFNER ANGLE OR C m o.o 1 —= oao teolSTRUT IF REQUIRED. y�°., ROD STIFFNER ANGLE OR tl STRUT IF REQUIRED. o c co DUCT ROD COUPLING FOR ... c ti ADDITIONAL UPPER = �UC ROD COUPLING FOR (�°C o ■ CD LOWER ROD ATTACHMENT. „o y 'o E SUPPORT TO STIFFEN LOWER ROD ATTACHMENT. m o. 0co 0 ADDITIONAL UPPER �"�" � m� C ��„�� DUCT SUPPORT TO STIFFEN irr ASBH OPTIONAL NO.10 SELF-TAPPING DUCT 1 IN. �t , o o. 1 9co e� m SHEET METAL SCREWS NO.10 SELF-TAPPING .� ,�,-�+ L_JLL ATTACHMENT SHEET METAL SCREWS U0 n MAXIMUM 12 IN.O.C.TOP v SEISMIC RESTRAINT SCHEDULE --- ANDBOMAXIMUM121N.O.C.TOP a>' A ��- AND BOTTOM Q a c°�° 4,00-003: oU Y � �� AND BOTTOM TRAPEZE SUPPORT 01n$(coo TRAPEZE SUPPORT C 3� PROVIDE SEISMIC SWAY BRACE ON ALL SUSPENDED PIPING PER 2012 IBC. W 23 SEISMIC SWAY BRACES SHALL CONSIST OF GALVANIZED STEEL AIRCRAFT • • • • ® " . . . . " . ® 0 CABLES OR STEEL ANGLES/CHANNELS. STEEL AIRCRAFT CABLES SHALL BE , PRESTRETCED TO ESTABLISH A CERTIFIED MINIMUM MODULUS OF ELASTICITY. AIRCRAFT CABELSTEEL BRACE m CABLE BRACES SHALL BE DESIGNED TO RESIST SEISMIC TENSION AND STEEL MAXIMUM -6" J ~ BRACES SHALL BE DESIGNED TO RESIST BOTH TENSION AND COMPRESSION MASON TYPE SCBH LOADS WITH A MINIMUM SAFETY FACTOR OF 2. BRACE END CONNECTIONS SHALL SEISMIC BRACKET MASON TYPE SSB BE STEEL ASSEMBLIES THAT SWIVEL TO THE FINAL INSTALLATION ANGLE. DO SEISMIC BRACKET NOT MIX CABLE AND STEEL BRACES TO BRACE THE SAME SYSTEM. STEEL ANGLES, WHEN REQUIRED, SHALL BE CLAMPED TO THE THREADED HANGER RODS AT THE SEISMIC SWAY BRACE LOCATIONS UTILIZING A MINIMUM OF TWO DUCTILE IRON CLAMPS. THE BRACING SYSTEM SHALL HAVE AN ANCHORAGE Revisions PREAPPROVAL'R" NUMBER FROM ARECOGNIZED GOVERNMENT AGENCY TRANSVERSE SEISMIC CABLE BRACE TRANSVERSE SEISMIC SOLID BRACE ISSUED FOR LANDLORD REVIEW SHOWING MAXIMUM RESTRAINT RATINGS VERIFYING ITS CAPABILITY TO RESIST SEISMIC FORCES. CABLE BRACE ASSEMBLIES SHALL BE TYPE SCB, STEEL BRACE 04 FOR RECTANGULAR DUCT O� FOR RECTANGULAR DUCT I01-21-2015 SSUEDF ASSEMBLIES SHALL BE TYPE SSB, ROD CLAMPS SHALL BE TYPE SRC, PIPE CLEVIS NOT TO SCALE NOT TO SCALE ISSUED FOR PERMIT 02-04-2015 BRACES SHALL BE TYPE CCB AND MULTIPLE ANCHOR LOAD DISTRIBUTION D BRACKETS SHALL BE TYPE SLDB ALL AS MANUFACTURED BY MASON INDUSTRIES, Q INC. OR EQUAL AS APPROVED BY LOCAL AUTHORITIES. A 0 0 0 a M f� th r r O N N J_ Signature Q 0 12015 W Date Q 6 1 Expiration Date Z ENGINEER W 1- 1 HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- 0 PARED UNDER MY SUPERVISION AND THAT TO THE BEST Z OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, I REGULATIONS AND ORDINANCES OF PORTLAND,OREGON C7 RELATING TO STRUCTURES AND BUILDINGS. 0I ENGINEER CO Drawn By Checked By CW SK co �I Scale Date 0) AS SHOWN 01-06-2015 v Job No. 14-2115 cr) co Sheet No. M3 . 1 MP GENERAL NOTES MECHANICAL EQUIPMENT NOTES Ay� A. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED ACCORDING TO 1. ALL HOODS,EXHAUST FANS AND MAKE-UP AIR UNIT ARE INSTALLED BY SPECIALIZED NATIONAL ACCOUNT TEAMS MANUFACTURER'S INSTALLATION INSTRUCTIONS,SHOP DRAWINGS AND MECHANICAL CONTRACTOR AND FURNISHED BY NOODLES&CO.CONTACT STEVE RESTAURANTS&ENTERTAINMENT L APPROPRIATE DETAILS. ( ) DUNCAN SR.AT THE CAPTIVE-AIRF COMPANY, 800 762-1078. JOSHUA PLUMMER-PRIMARY NATIONAL ACCOUNT SALES ADMINISTRATOR LENNOX INDUSTRIES" B. CONDENSATE TO SLOPE AT 1/8"PER FOOT.CONSTRUCTED WITH SANITARY 2. LENNOX ROOFTOP UNITS ARE INSTALLED BY MECHANICAL CONTRACTOR AND PO BOX 799900 � \ FITTINGS. 1"MINIMUM SIZE. FURNISHED BY NOODLES&CO. CONTACT LENNOX'S NATIONAL ACCOUNTS DALLAS,TX 75379-9900 � . DEPARTMENT. PHONE-(800)367-6285 C. CONDENSATE DRAINS FROM MECHANICAL EQUIPMENT ON ROOF SHALL BE BAROMETRIC RELIEF DIRECT LINE-(972)497-6784 \ \ 3. CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY ON OWNER FURNISHED FAX- 800 572-4001 � • COPPER.ROUTE AS SHOWN ON DRAWINGS. ( ) EQUIPMENT. CONTRACTOR SHALL INCLUDE COSTS FOR RECEIVING,HANDLING, E-MAIL-JOSHUA.PLUMMER@LENNOXIND.COM s s� D. MAINTAIN CODE REQUIRED MINIMUM DISTANCE OF(10'-0")BETWEEN EXHAUST STORAGE,AND HOISTING OF OWNER FURNISHED EQUIPMENT. HOURS 8AM-5PM(CST) FANS OR VTR'S AND OUTSIDE AIR INTAKES OF ROOFTOP UNITS.PROVIDE RESPONSIBILITIES-INSIDE SALES CONTACT AT THE LENNOX CORPORATE OFFICES INS SWEETVENTS ON ALL VENT STACKS. 8 4. NOODLES&COMPANY RESTAURANT HAS A NATIONAL ACCOUNT AGREEMENT DALLAS, TX FOR NOODLES & COMPANY. MANAGES ALL ASPECTS OF SHIPMENT ANDA.&ffi WITH LENNOX INDUSTRIES AND WILL BE PURCHASING ALL LENNOX EQUIPMENT DELIVERY. MAIN POINT OF COMMUNICATION FOR ALL INQUIRES. 4' E. VERIFY ALL ROOFTOP UNIT AND EXHAUST FAN OPENINGS AND WEIGHTS WITH DIRECT. INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO RECEIVE AND THE STRUCTURAL ENGINEER AND LANDLORD WITH DIMENSIONS AND WEIGHTS I INSPECT ALL UNITS FOR ANY DAMAGE INCURRED DURING SHIPPING AND REPORT REGIONAL TECHNICAL CONSULTANT av OF THE ACTUAL RTU'S&FANS USED. O 30'x14" ANY DAMAGE TO BOTH NOODLES&COMPANY AND LENNOX.ALL DAMAGE MUST ROBBIE TEAGUE w BE RECORDED ON THE SHIPPING BILL OF LADING. LENNOX INDUSTRIES - - - ----- F. ALL ROOFTOP EQUIPMENT SHALL BE LABELED WITH 2"HIGH STENCIL LETTERS IN -r.. PO BOX 799900 BLACK PAINT AND SHALL INCLUDE UNIT NUMBER AND AREA SERVED.I.E.:RTU-1 = DN S. LENNOX WILL SUPPLY THE INSTALLING CONTRACTOR A LIST OF ALL UNITS AND DALLAS,TX 75379-9900 N&C DINING. ACCESSORIES BEING SUPPLIED ON THE PROJECT. IN ADDITION,COMPLETE PHONE-(800)367-6285 SUBMITTALS WILL ALSO BE SUPPLIED. A PROJECT SHIPPING INFORMATION DIRECT LINE-(972)497-5381 r G. WIRE AND CONDUIT SIZES ARE MINIMUM.THE CONTRACTOR SHALL UP-SIZE 7 I' i SHEET WILL BE INCLUDED WITH THE SUBMITTALS TO BE COMPLETED BY THE FAX(972)497-7290 00 WIRING AS REQUIRED TO SATISFY A 3%MAXIMUM VOLTAGE DROP. INSTALLING CONTRACTOR AND RETURNED DIRECTLY TO LENNOX PRIOR TO E-MAIL-ROBBIE.TEAGUE@LENNOXINTL.COM SHIPPING. HOURS-7AM-4PM(CST) H. CONTRACTOR SHALL CAREFULLY REVIEW CONTRACT DOCUMENTS INCLUDING W THE DRAWING AND PROJECT MANUAL. INFORMATION REGARDING WORK OF THE g "x14" I 6. INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO CONFIRM THE EQUIPMENT RESPONSIBILITIES-OFFERS TECHNICAL SUPPORT FOR BOTH SERVICE AND VARIOUS TRADES AND SUBCONTRACTORS ARE DISPERSED THROUGH OUT THE ( O LIST OF MATERIAL,SUBMITTALS,AND VOLTAGE OF ALL UNITS PRIOR TO INSTALLATION OF ALL LENNOX PRODUCTS TO MECHANICAL CONTRACTORS AND DOCUMENTS AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE ) ORDERING. TECHNICIANS. O Q TO THE FULL SET OF DOCUMENTS. I 7. INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO COORDINATE ALL SHIPPING NATIONAL ACCOUNT MANAGER Q L CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL UTILITIES ABOVE THE I OF EQUIPMENT DIRECTLY WITH LENNOX NATIONAL ACCOUNTS. CODY JACKSON O CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION 218A O Q NATIONAL ACCOUNT MANAGER AND FUTURE CHANGES IN MECHANICAL EQUIPMENT.CONDUIT AND PIPE TO BE - 8. INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO WARRANTY ALL LABOR FOR LENNOX INDUSTRIES W RUN UP IN JOISTS SPACE.COORDINATE SERVICE AND ACCESS POINTS ABOVE A PERIOD OF ONE YEAR FROM THE STORE OPENING DATE. 1008 WEST 2780 SOUTH CEILING TO MINIMIZE REQUIRED ACCESS. CONDENSING I ' SALT LAKE CITY,UT 84119 UNIT FOR ICE RTU 9. LENNOX INDUSTRIES WARRANTEES ALL PARTS ONE YEAR,COMPRESSORS FOR 5 PHONE-(801)736-8904 z Q J. ALL ELECTRICAL EQUIPMENT MOUNTED ON ROOF(RECEPTACLES, DISCONNECT MACHINE O®f 3] I YEARS,AND HEAT EXCHANGERS FOR 10 YEARS, LESS LABOR. CELL-(801)350-1563 SWITCHES, ETC.)SHALL BE WEATHERPROOF AND/OR NEMA 3R. 200 LBS _f E-MAIL-CODY.JACKSON@LENNOXIND.COM Q 1,500 L S 10. INSTALLING CONTRACTOR IS RESPONSIBLE FOR STARTING UP ALL UNITS AND SUPPORT-(800)367-6285 (n 3,000 CFM SEE DETAIL FOR DUCT K. REFER TO MECHANICAL AND HOOD DRAWINGS FOR ADDITIONAL ELECTRICAL MAKING SURE THAT THEY ARE ALL FUNCTIONING PROPERLY. REQUIREMENTS.PROVIDE ALL CONTROL CONDUIT AND WIRING AS REQUIRED 180 CFH ( SUPPORT DETAIL(TYPICAL) RESPONSIBILITIES-OVERSEES ALL FUNCTIONS OF ACCOUNT.CORPORATE LIAISON z FOR INTERLOCKING FANS,MOTORS, ETC.AS INDICATED ON THE MECHANICAL 3/4"(180)-/ 286A O4 11. INSTALLING CONTRACTOR CAN CONTACT THE FOLLOWING LENNOX NATIONAL BETWEEN LENNOX INDUSTRIES AND NOODLES&COMPANY. O AND HOOD DRAWINGS. BAROMETRIC RELIEF ACCOUNT TEAM MEMBERS TO ASSIST IN THE PROCESS: O I- i � L. ALL ELECTRICAL EQUIPMENT ON ROOFTOP EQUIPMENT SHALL BE MOUNTED ON A CONDENSING ( z M z NON-REMOVABLE PANEL OF THAT EQUIPMENT.THIS LOCATION SHALL BE 2 UNIT FOR N COORDINATED WITH THE MECHANICAL OR PLUMBING CONTRACTOR PRIOR TO _ _ WALK-IN 06 = ROUGH-IN. COOLER I ( t 250 LBS i Q M. ALL WIRE FOR ROOF MOUNTED EQUIPMENT SHALL BE PROVIDED WITH 90"THHN RTUO®rj INSULATION. \ 1 /; UP0 500 LBS Q O N. ROOFTOP UNITS SHALL BE PROVIDED WITH FACTORY MOUNTED DISCONNECT 1, � --_ SWITCHES.SERVICE OUTLETS PROVIDED BY ELECTRICAL CONTRACTOR. 5,000 CFM 180 CFH 30"x20" / I i L1. 0. LANDLORD APPROVED ROOFING CONTRACTOR SHALL PERFORM ALL ROOFINGC14 Q) WORK TO MAINTAIN ROOFING WARRANTY. ( € O O s I I z ,- PLUMBING PLAN NOTES -_ _ --� _ - ---fl _ ....-- - _ -- 1 ---- -- - - -- ...... --- - ----- . _ \ PROVIDE FITTINGS& 1❑ GAS PIPE DOWN THROUGH ROOF.SEE"ROOF PENETRATION"DETAIL ON SHEET i+� ?! OFFSETS AS REQUIRED ! •o o P4.0,AND REFER TO SHEET P1.1 FOR CONTINUATION. 1 L _ TO STACK DUCTWORK I 1 V c a 30" j (TYPICAL) ( C m o 0 22l ROUTE GAS PIPE ON ROOF PER"ROOF BLOCKING PIPE SUPPORT'DETAIL ON 1 __._.___ = a e EF 2 „a SHEET P4.0.PAINT GAS PIPING WITH RUST RESISTANT YELLOW PAINT. 7 / �-� c p c0 ROOFTOP EQUIPMENT:SEE"ROOFTOP UNIT CONNECTIONS"AND"MAKE-UP AIR 325 LBS }� co00 UNIT CONNECTION"DETAILS ON SHEET P4.0 FOR CONNECTION REQUIREMENTS. ' ( \ �� ; 1 .«. -" °D X - ( aO ;:. V th NE ® FIELD COORDINATE ALL NOODLES ROOFTOP EQUIPMENT LOCATIONS AND VENT U o \ � f � a ,�� ro TERMINATIONS TO MAINTAIN CODE REQUIRED DISTANCES AND EQUIPMENT I �� \ I �. ma) 0 REQUIRED CLEARANCES. \\ `°0 cm x m G / -- ..-- -- - ------ --- ------- --- --- -- -- -- -- =Hoa {A o_m c 3/4"(180) t C�o ^ k m m m PROVIDE BRADFORD WHITE#239-44069-01 CONCENTRIC VENT TERMINAL KIT FOR ^ UQ 0 WATER HEATER.ROUTE UP TO ABOVE ROOF AND TERMINATE PER MANUFACTURER'S RECOMMENDATIONS.CONTACT LANDLORD'S ROOFING 1'(269) G- _� \ 1 ts--� U Q r o� C o X00 CONTRACTOR TO FLASH PENETRATIONS.EXTEND EXHAUST VENT MIN T-0" _ ! oro 3 ABOVE ANY OUTSIDE AIR INTAKE WITHIN 10'-0"PER CODE. F �� / O8 30"x14" jC 305 3 30"x20• 2 © PROVIDE NEW VENT THRU ROOF IN THIS VICINITY PER"VENT THRU ROOF(VTR)" Og r �� 2 I 3 30"x14" 0 DETAIL ON SHEET P4.0. LOCATE VENT THRU ROOF A MINIMUMOF AWAY 00"1 '- I' m 325 LBS 24"x18" a FROM NEAREST AIR INTAKE ON ROOF. L / • �, ;O` 30"x20" z F ❑7 PRCESSURE REDUCING VALVE. INLET PRESSURE IS 2 PSI,OUTLET PRESSURE IS 7" \ / O6 4"VTR ( - MUA O®�\ / ' F I ® EXISTING ROOF DRAINS TO REMAIN,PROTECT PIPING DURING CONSTRUCTION. 1 7L-- - 18"x24 1,000 LBS \ / } x69-f F fi F i MECHANICAL PLAN NOTES � Revisions ISSUED FOR LANDLORD REVIEW OINSTALL OWNER FURNISHED ROOFTOP UNIT AND ROOF CURB.COORDINATE 1 UNIT WITH STRUCTURE.SHIM UNIT AND CURB LEVEL FOR PROPER CONDENSATE 01-21-2015 ISSUED FOR PERMIT DRAINAGE.PROVIDE FLEXIBLE CONNECTORS ON THE SUPPLY AND RETURN AIR _ �02-04-2015 DUCT CONNECTIONS.TRANSITION TO DUCT SIZES SHOWN.PROVIDE DUCTWORK ' AND AIR DISTRIBUTION DEVICES AS INDICATED ON THE PLAN.REFER TO I ROOFTOP UNIT SCHEDULE FOR ADDITIONAL REQUIREMENTS. I , ' , : 2 INSTALL OWNER FURNISHED ROOF MOUNTED GREASE EXHAUST FAN,AND -- GREASE GUARD SYSTEM.COORDINATE INSTALLATION OF FAN WITH LANDLORD r n Q TO ENSURE THAT ANY ADJACENT TENANT DOES NOT INSTALL ANY OUTSIDE AIR INTAKE WITHIN 10 FEET OF THE EXHAUST FAN.CONTACT THE ENGINEER IF THE EXHAUST FAN MUST BE RELOCATED.REFER TO SHEETS M2.0 AND M3.0 FOR i Q ADDITIONAL INFORMATION. i I SUPPLY AIR FROM RTU-1 TO BE INSTALLED ABOVE \2/ MANSARD Q 3 INSTALL OWNER FURNISHED MAKE-UP AIR UNIT.PROVIDE FLEXIBLE CONNECTOR ON THE SUPPLY DUCT CONNECTION.TRANSITION TO DUCT SIZES SHOWN.PROVIDE DUCTWORK AND AIR DISTRIBUTION DEVICES AS INDICATED I ON THE PLAN.REFER TO SHEET M2.0 FOR ADDITIONAL INFORMATION. j O41. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH REMOTE CONDENSING UNIT FOR WALK-IN COOLER, REFRIGERANT LINE SET,THERMOSTATIC EXPANSION VALVE,SOLENOID VALVE,TEMPERATURE CONTROL,SIGHT GLASS, FILTER DRIER,PRESSURE CONTROL,CRANK CASE HEATER,LOW 77 AMBIENT CONTROLS,WEATHERPROOF HOUSING,AND RACK FOR CONDENSING UNIT. d 2. GENERAL CONTRACTOR SHALL INSTALL AND SUPPORT CONDENSING UNIT ABOVE ROOF. INSTALL EQUIPMENT PER MANUFACTURER'S ' C.0 RECOMMENDATIONS.TRAP AND SLOPE REFRIGERANT LINES PER 00 MANUFACTURER'S RECOMMENDATIONS 3. GENERAL CONTRACTOR SHALL PROVIDE PIPE CURB ASSEMBLY FOR ALL 1 LID ROOF PENETRATIONS.SEAL PIPING PENETRATIONS THROUGH COOLER ; = C) ROOF.ALL ROOF PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE t I 1 GENERAL CONTRACTOR. I CV i ; I g Signature Z 15 1. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH REMOTE CONDENSING ( € 02/04/2015 Q UNIT FOR ICE MACHINE, REFRIGERANT LINE SET,THERMOSTATIC EXPANSION Date d VALVE,SOLENOID VALVE,TEMPERATURE CONTROL,SIGHT GLASS,FILTER � ' i 06/30/2016 U_ DRIER,PRESSURE CONTROL,CRANK CASE HEATER,LOW AMBIENT l Expiration Date O CONTROLS,WEATHERPROOF HOUSING,AND RACK FOR CONDENSING UNIT. 0 2. GENERAL CONTRACTOR SHALL INSTALL AND SUPPORT CONDENSING UNIT 1 € ENGINEER I s � d EQUIPMENT ABOVE ROOF.INSTALL EQUIPMENT PER MANUFACTURER'S I IHEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- RECOMMENDATIONS.TRAP AND SLOPE REFRIGERANT LINES PER 1 PARED uNOERnavSUPERVISION AND THATTOTHEBEST 1 MANUFACTURER'S RECOMMENDATIONS. OFMYKNOWLE KNOWLEDGE, ORDINANCESMOFPORTLANA OREGON 3. GENERAL CONTRACTOR SHALL PROVIDE PIPE CURB ASSEMBLY FOR ALLREGULATIONS I OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, D_ ROOF PENETRATIONS.SEAL PIPING PENETRATIONS THROUGH COOLER ROOF. I i RELATING TO STRUCTURES AND BUILDINGS. ` I ALL ROOF PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE t- GENERAL CONTRACTOR. t 00 4. REFRIGERANT LINES BELOW ROOF SHALL BE CONCEALED WITHIN WALLS SO i ENGINEER � THAT THEY ARE NOT VISIBLE FROM DINING OR SERVING AREAS. 1 s ; Drawn By Checked By 46 EXHAUST FROM EF-3.TERMINATE WITH GOOSENECK AND PROVIDE BIRD ; CW SK Irt� a_ SCREEN. MAINTAIN 10'-0"CLEARANCE FROM ALL OUTSIDE AIR INTAKES. -" j I Scale Date rnl 7O EXHAUST FROM EF-4.TERMINATE WITH GOOSENECK AND PROVIDE BIRD I a I 3 ; 1/4 = 1'-0" 01-06-2015 .- SCREEN.MAINTAIN 10'-0"CLEARANCE FROM ALL OUTSIDE AIR INTAKES. e ( i i s ! I i . Job No. 3 r 14-2115 O INSULATE ROOF MOUNTED DUCTWORK WITH MIN.2"THICKNESS OF 6 PCF RIGID MP ROOF PLAN 3. FIBERGLASS BOARD INSULATION WITH WEATHER PROOF JACKET COMPLETELY NORTH o SEALED WATER TYPE AND PROVIDE CROWNED FOR TOP OF DUCTWORK FOR 1!4"=1'-0" DRAINAGE. INSULATION SHALL BE MINIMUM R-8 OR HIGHER AS REQUIRED BY THE v LOCAL CODE. Sheet No. PIAN MP1 . 0 ------ --- ----- - --------- ---- -- ------ ----- -- GENERAL MECHANICAL REQUIREMENTS GENERAL MECHANICAL SPECIFICATIONS GENERAL PLUMBING REQUIREMENTS PLUMBING SPECIFICATIONS e= _. - 1. HVAC SUBCONTRACTOR SHALL PROVIDE AT BID TIME A BID TO PROVIDE PROVIDE EQUIPMENT INDICATED ON THE DRAWINGS,AND AS REQUIRED FOR A DUCT TURNING VANES: 1. GCS PLUMBING CONTRACTOR SHALL COORDINATE UTILITY WORK, THE WORK INCLUDES MODIFICATION TO THE EXISTING PLUMBING SYSTEM AND CLEANOUTS: PREVENTATIVE MAINTENANCE SERVICES FOR ONE YEAR COMPLETE FUNCTIONING SYSTEM. PROVIDE FABRICATED TURNING VANES AND VANE RUNNERS,CONSTRUCTED IN PLUMBING, AND GAS,WITH NOODLES&COMPANY'S COORDINATOR UPON PROVIDING NEW MATERIALS,FITTINGS AND ACCESSORIES NECESSARY FOR A PROVIDE CLEANOUTS AT THE END OF EACH HORIZONTAL RUN,AND AT THE BASE ACCORDANCE WITH SMACNA'HVAC DUCT CONSTRUCTION STANDARDS". AWARD OF CONTRACT GENERAL CONTRACTOR WILL COMPLETE AND COMPLETE FUNCTIONING PLUMBING SYSTEM.THE WORK ALSO INCLUDES OF ALL VERTICAL WASTE AND DRAIN PIPES.CLEANOUTS SHALL BE OF THE SAME 2. HOOD SUBCONTRACTOR SHALL PROVIDE AT BID TIME A BID TO PROVIDE DEFINITIONS: PROVIDE TURNING VANES CONSTRUCTED OF CURVED BLADES,SUPPORTED ROUGH-IN AND FINAL CONNECTIONS TO FOOD SERVICE EQUIPMENT AND SIZE AS THE PIPES THEY SERVE.CONFORMING TO CODE REQUIREMENTS. PREVENTATIVE MAINTENANCE SERVICES FOR ONE YEAR FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE,READY FOR WITH BARS PERPENDICULAR TO BLADES,AND SET INTO SIDE STRIPS SUITABLE FORWARD ALL UTILITY INFORMATION FOR TRANSFER OF SERVICE FROM BEVERAGE DISPENSING EQUIPMENT PROVIDED BY OTHERS.ALL WORK SHALL BE PROVIDE SUITABLE WALL OR FLOOR CLEANOUTS WITH ACCESSORIES TO !1®t 11 - 3. NOODLES&COMPANY RESTAURANT HAS A NATIONAL ACCOUNT INSTALLATION. FOR MOUNTING IN DUCTWORK FOLLOW SMACNA GUIDELINES FOR SPACING LANDLORD'S NAME TO INTO NOODLES&COMPANY'S NAME. IN ACCORDANCE WITH STATE AND LOCAL CODES AND/OR ORDINANCES AND IS OBSCURE FROM VIEW. I I A& AGREEMENT WITH LENNOX INDUSTRIES AND WILL BE PURCHASING LENNOX INSTALL MEANS TO PLACE IN POSITION AND MAKE CONNECTIONS FOR SERVICE SUPPORT,AND CONSTRUCTION.ALL BLADES SHALL BE DOUBLE THICKNESS 2. GCS PLUMBING CONTRACTOR SHALL INCLUDE IN BID ANY MODIFICATIONS SUBJECT TO INSPECTION. = OR USE AIRFOIL TYPE. WATER DISTRIBUTION PIPING: TO EXISTING FIRE SPRINKLERS SYSTEM REQUIRED FOR NEW TENANT EQUIPMENT DIRECT. GENERAL CONTRACTOR SHALL PROVIDE ALL OTHER PROVIDE MEANS TO FURNISH AND INSTAL.,COMPLETE AND READY FOR HOOK-UP CHARGES,PERMITS AND ALL OTHER EXPENSES RELATED TO A LAYOUT WATER PIPING SO THAT THE ENTIRE SYSTEM CAN BE DRAINED.HOT P . EQUIPMENT.INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO RECEIVE INTENDED USE. FLEXIBLE DUCT CONNECTORS: IMPROVEMENT WORK COMPLETE AND FUNCTIONING PLUMBING SYSTEM ARE INCLUDED AS A PART OF AND COLD WATER PIPING SHALL BE 12"MIN.TYPE L COPPER TUBING WITH _ - AND INSPECT ALL UNITS FOR ANY DAMAGE INCURRED DURING SHIPPING PROVIDE U.L.LABELED 30 OUNCE NEOPRENE COATED FIBERGLASS FABRIC 3. ALL EXPOSED DRAIN PIPES AND CONDENSATE DRAINS IN KITCHEN ARE THIS SECTION. WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS.PIPING SHALL - AND REPORT ANY DAMAGE TO BOTH NOODLE'S&COMPANY AND LENNOX. WARRANTY: DUCT CONNECTORS. COPPER TYPE"M"WITH WALL OR FLOOR SUPPORTS CONFORM TO ASTM B42,AND ASTM B88 STANDARDS PER STATE AND LOCAL ALL DAMAGE MUST BE RECORDED ON THE SHIPPING BILL OF LADING. PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS WARRANTY: CODES AND/OR ORDINANCES.PROVIDE WATER HAMMER ARRESTERS AT EACH AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL TESTING AND BALANCING: 4. ALL HOT WATER LINES IN ENTIRE PREMISES SHALL BE INSULATED PER PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS FIXTURE OR GROUP OF FIXTURES AS REQUIRED.INSTALL CHROME PLATED =- LENNOX WILL SUPPLY THE INSTALLING CONTRACTOR A LIST OF ALL UNITS COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT.PROVIDE GENERAL CONTRACTOR SHALL CONTRACT DIRECTLY WITH SUPERIOR INC.TO PLANS AND SPECIFICATIONS AND/OR PER DIRECTION OF NOODLES& AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL BRASS ESCUTCHEON PLATES AT ALL PENETRATIONS THROUGH FINISHED AND ACCESSORIES BEING SUPPLIED ON THE PROJECT. IN ADDITION, A SEPARATE LINE ITEM DEDUCT AMOUNT ON THE PROPOSAL FORM TO DELETE PROVIDE A THIRD PARTY TEST AND BALANCE OF THE HVAC SYSTEM.THE COMPANY'S CONSTRUCTION MANAGER. COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT.PROVIDE SURFACES(INCLUDING CABINET INTERIORS).USE TIN-ANTIMONY SOLDER,9515 = COMPLETE SUBMITTALS WILL ALSO BE SUPPLIED. A PROJECT SHIPPING WARRANTY SERVICE,AT THE OWNER'S OPTION. CONTRACTOR SHALL INCLUDE GENERAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE TEST AND A SEPARATE LINE ITEM DEDUCT AMOUNT ON THE PROPOSAL FORM TO DELETE FOR ALL SWEAT FITTINGS OF COPPER PIPING.ALL SOLDERED JOINTS SHALL INFORMATION SHEET WILL BE INCLUDED WITH THE SUBMITTALS TO BE ONE YEAR WARRANTY ON OWNER FURNISHED EQUIPMENT. CONTRACTOR BALANCE.CONTACT SUPERIOR INC.(ERIC HOLCOMB)@(800)222-1819 AND(615) 5. ALL FLOOR SINKS ARE TO BE PORCELAIN COATED CAST IRON WITH WARRANTY SERVICE,AT THE OWNER'S OPTION. CONFORM TO ASTM B32.PLASTIC PIPING IS NOT ACCEPTABLE FOR WATER COMPLETED BY THE INSTALLING CONTRACTOR AND RETURNED DIRECTLY SHALL INCLUDE COSTS FOR RECEIVING,HANDLING,STORAGE,AND HOISTING OF 479-1578 FOR COORDINATION AND SCHEDULING.TEST AND ADJUST ALL ALUMINUM DEBRIS BASKETS AND%COVER GRATES.GCS PLUMBING PIPING.THE EXISTING DOMESTIC WATER SYSTEM SHALL BE FLUSHED, TO LENNOX PRIOR TO SHIPPING.INSTALLING CONTRACTOR WILL BE OWNER FURNISHED EQUIPMENT. MECHANICAL SYSTEMS AND EQUIPMENT TO ASSURE PROPER BALANCE AND CONTRACTOR IS TO PROVIDE. THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK PRESSURE TESTED AND PURIFIED THE SAME AS REQUIRED FOR A NEW SYSTEM. V_ RESPONSIBLE TO CONFIRM THE EQUIPMENT LIST OF MATERIAL, OPERATION.PERFORM TESTS IN ACCORDANCE WITH NEBB OR AABC,AND REQUIRED FOR THE PROJECT.THE DRAWINGS FOR PLUMBING WORK ARE I 00 _ PROVIDE OPERATION MANUALS,MAINTENANCE MANUALS AND SCHEMATICS FOR ASHRAE STANDARDS.ELIMINATE NOISE AND VIBRATION,AND ASSURE PROPER 6. GCS PLUMBING CONTRACTOR TO PROVIDE ALL FAUCET(S)INCLUDING DIAGRAMMATIC,SHOWING THE GENERAL LOCATION,TYPE,FIXTURES AND PIPE INSULATION: yy..�� _ SUBMITTALS,AND VOLTAGE OF ALL UNITS PRIOR TO ORDERING.INSTALLING ALL MECHANICAL EQUIPMENT INSTALLED. FUNCTION OF CONTROLS.SUBMIT COMPLETED TEST AND BALANCE REPORT TO FAUCET FOR THE 3 COMPARTMENT SINK AND ALL OTHER SINKS. EQUIPMENT REQUIRED.THE DRAWINGS SHALL NOT BE SCALED FOR EXACT INSULATE ALL LISTED SERVICE PIPING AS FOLLOWS.DOMESTIC COLDIHOT 'L'+- CONTRACTOR WILL BE RESPONSIBLE TO COORDINATE ALL SHIPPING OF OWNERS REPRESENTATIVE BALANCING CONTRACTOR SHALL BE AN MEASUREMENTS. REFER TO MANUFACTURER'S STANDARD ROUGH-IN WATER,HOT WATER RETURN,STORM WATER PIPING.PROVIDE 1'PREFORMED EQUIPMENT DIRECTLY WITH LENNOX NATIONAL ACCOUNTS CONTACT;JOSH COORDINATION: INDEPENDENT CERTIFIED TEST AND BALANCE CONTRACTOR.WITH NEBB OR 7. GCS PLUMBING CONTRACTOR SHALL PROFESSIONALLY LABEL ALL WATER DRAWINGS FOR PLUMBING FIXTURE INSTALLATION REQUIREMENTS.COMPLY FIBERGLASS,ASJISS-11.FLAME SPREAD 25,SMOKE DEVELOPED 50,ASTM C4547. WN PLUMMER(JOSHUA.PLUMMEROLENNOXIND.COM/972-497-6784)JWIO NSTANG COORDINATE WITH THE WORK OF OTHER SECTIONS,EQUIPMENT FURNISHED BY AABC CERTIFICATION.BALANCE ALL SYSTEMS TO WITHIN 5%OF AIR FLOWS OUTLETS,VALVES,ETC AS DIRECTED BY THE NOODLES&COMPANY WITH ALL APPLICABLE ADA INSTALLATION REQUIREMENTS. FOR CONDENSATE PIPING PROVIDE 112'THICK INSULATION OF SAME W CONTRACTOR WILL BE RESPONSIBLE TO WARRANTY ALL LABOR FOR A OTHERS,REQUIREMENTS OF THE OWNER AND WITH THE CONSTRAINTS OF THE INDICATED ON THE DRAWINGS,AND REPORT ALL DISCREPANCIES TO HVAC CONSTRUCTION MANAGER CHARACTERISTICS AS LISTED FOR 1"ABOVE WHERE PERMITTED BY LOCAL O EXISTING CONDITIONS OF THE PROJECT SITE. INSTALLER FOR CORRECTION.MARK FINAL BALANCE POSITIONS ON DAMPERS COORDINATE WITH THE WORK OF OTHER SECTIONS,EQUIPMENT FURNISHED BY CODES,PROVIDE 112"SELF-ADHESIVE UNICELLULAR FOAM PIPE INSULATION PERIOD OF ONE YEAR FROM THE STORE OPENING DATE. LENNOXWITHPERMANENT MARKER 8. GCS PLUMBING CONTRACTOR IS REQUIRED TO'JET-(WATER CLEAN)ALL OTHERS,AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE WITH PRE-FORMED PVC FITTING COVERS-EQUAL TO SELF-ADHESIVE I..... INDUSTRIES WARRANTEES ALL PARTS ONE YEAR,COMPRESSORS FOR 5 DUCT DIMENSIONS: DRAINS UNDERGROUND SEWER LINES,BOTH NEW AND EXISTING;THEY ARE PROJECT SITE. ARMSTRONG 2000 WITH K FACTOR OF 0.27 AT 75 DEGREES MEAN TEMPERATURE. ♦�//J�� - YEARS,AND HEAT EXCHANGERS FOR 10 YEARS, LESS LABOR.INSTALLING UNLESS OTHERWISE NOTED,DUCT DIMENSIONS ON THE DRAWINGS ARE INSIDE TYPE I HOOD EXHAUST DUCTWORK: TO BE HIGH PRESSURE JET CLEANED AT THE END OF THE PROJECT 24 INSULATE ANY EXPOSED CONDENSATE PIPING WITH WASTE TEMPERATURE v a CONTRACTOR CAN CONTACT THE FOLLOWING LENNOX NATIONAL ACCOUNT CLEAR DtMENS10NS, CONTRACTOR SHALL BE RESPONSIBLE FOR OPTION A OR OPTION B BELOW,AS HOURS PRIOR TO TURN OVER THE GC'S PLUMBING CONTRACTOR IS TO PIPING SYSTEMS-GENERAL: BELOW 60 DEGREES F. - TEAM MEMBERS TO ASSIST IN THE PROCESS:JOSH PLUMBER INDICATED ON CAPTIVEAiRE DRAWINGS.REFER TO CAPTlVEAIRE DRAWINGS SUBMIT TO NOODLES&COMPANY A REPORT FROM THE SUBCONTRACTOR ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINES AND SUPPORTED AND W - SHEET METAL DUCTWORK: FOR ADDITIONAL INFORMATION. ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION.ALL SHUTOFF VALVES: (JOSHUAPLUMMEROLENNOXIND.COM 1972-497-6784).LENNOX HVAC ROOF DOING THE WORK CERTIFYING THAT THE ABOVE WORK HAS BEEN } PROVIDE SHEET METAL DUCTWORK FABRICATED AND INSTALLED IN PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES.INSTALL AS SHUT OFF VALVES WITH UNIONS SHALL BE PROVIDED FOR SERVICE TO EACH TOP EQUIPMENT PACKAGE INCLUDING ROOF CURBS WILL BE PROVIDED BY COMPLETED. Q - ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS,FOR 1'W.G.PRESSURE A ROUND EXHAUST DUCT(OWNER FURNISHED): REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS AND TO ALLOW FOR PLUMBING FIXTURE,FOOD SERVICE EQUIPMENT ITEM OR OTHER EQUIPMENT Z _ NOODLES&COMPANY AND INSTALLED BY GENERAL CONTRACTOR ALL � CLASS,SEAL CLASS"A".SHEET METAL SHALL BE GALVANIZED SHEET STEEL OF INSTALL REDUCED CLEARANCE DOUBLE WALL GREASE DUCT AS 9. GCS PLUMBING CONTRACTOR WILL INSTALL A SOLID PVC COVER CAP OVER INSTALLATION OF OTHER WORK SUCH AS DUCTS AND ELECTRICAL CONDUIT.AT ITEM,TO FACILITATE ISOLATION FOR REPAIR OR REPLACEMENT.VALVES SHALL < a Z - DUCT WORK AND CONNECTIONS ALL INCLUSIVE ARE PROVIDED BY GENERAL LOCK FORMING QUALITY,ASTM A653 AND A924.ALL ANGLE IRON USED FOR SPECIFIED.REFER TO SHEET H4.0 FOR REQUIREMENTS.EXHAUST ALL CONNECTIONS BETWEEN FERROUS PIPING AND NONFERROUS PIPING, BE EQUAL TO JENKINS#902-T BALL VALVE,CHROME-FINISHED BRONZE,TEFLON - THE SODA CHASE AT THE BAG IN BOX ENDS OF THE SODA CHASE.GCS ^ CONTRACTOR GENERAL CONTRACTOR WILL RECEIVE ALL OF OWNER SUPPORT SHALL BE GALVANIZED.CONNECTIONS TO WALLS OR FLOOR SHALL BE DUCTWORK AND FITTINGS FURNISHED BY OWNER FOR INSTALLATION BY PROVIDE AN ISOLATING DI-ELECTRIC UNION.ALL.HANGERS SHALL BE SEATS AND PACKING,400 LB.W.O.G.,SOLDER END. L.L. � � - PLUMBING CONTRACTOR WILL DRILL A HOLE IN THE CAP LARGE ENOUGH 2 Z 2 SUPPLIED EQUIPMENT AND WILL BE SOLELY RESPONSIBLE TO MAINTAIN ALL AIRTIGHT WITH ANGLE IRON AND CAULKING.SEAL ALL DUCT SEAMS, THIS CONTRACTOR COMPATIBLE WITH PIPING MATERIAL TO PREVENT CORROSION.ALL PIPING EQUIPMENT IN PRISTINE NEW CONDITION. TRANSVERSE AND LONGITUDINAL,AIR TIGHT.PROVIDE TURNING VANES AT ALL FOR SODA LINES TO BE INSTALLED AND CAULKED AROUND COKE LINES MATERIALS SHALL COMPLY WITH STATE AND LOCAL CODES AND/OR ACCESS PANELS: 900 ELBOWS. NO FIREWRAP PRODUCT REQUIRED FOR ROUND DUCT INSTALLLATION. WRAP AFTER THEY HAVE BEEN INSTALLED. ORDINANCES. PANELS SHALL BE PROVIDED WHERE CONCEALED CONTROL DEVICES,VALVES, O O � 10. GCS PLUMBING CONTRACTOR WILL PROVIDE ALL ROOF PENETRATIONS All 4. CAPTIVE AIR HOOD AND EXHAUST PACKAGE WILL BE FURNISHED BY ETC.ARE CONCEALED WITHIN WALLS.WHERE ACCESS FOR ADJUSTMENT AND - NOODLES&COMPANY AND INSTALLED BY GENERAL CONTRACTOR TRAPEZE DUCT HANGERS: B RECTANGULAR EXHAUST DUCT(CONTRACTOR PROVIDED): PROVIDE ALL FITTINGS,ACCESSORIES,OFFSETS,AND MATERIALS NECESSARY MAINTENANCE IS POSSIBLE THROUGH LAY-IN SUSPENDED CEILINGS,ACCESS ""' PROVIDE MINIMUM 1X 2X 1X 18 GAUGE CHANNELS WITH MINIMUM 1'X 18 FABRICATE TYPE I EXHAUST DUCTS OF MINIMUM 16 GAUGE CARBON STEEL PLUMBING AND ALL CONDENSATE PIPING FOR WALK IN COOLER,ICE TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDICATED BY THE PANELS ARE NOT REQUIRED. Z M GENERAL CONTRACTOR WILL INCLUDE THE INSTALLATION AND TESTING OF N � Z THE FIRE SUPPRESSION SYSTEM. GENERAL CONTRACTOR WILL SCHEDULE GAUGE STRAPS TO STRUCTURAL SUPPORT. WHERE CONCEALED,AND OF MINIMUM 16 GAUGE STAINLESS STEEL MACHINE AND ALL RELATED REFRIGERATION. DESIGN AND THE EQUIPMENT INDICATED. 0 WHERE EXPOSED.JOINTS AND SEAMS SHALL BE CONTINUOUSLY WELDED INSTALLATION: = N J V - ALL LABOR AND MATERIALS AND PROVIDE ALL LABOR,MATERIAL AND 11. GCS PLUMBING CONTRACTOR WILL PROVIDE AND INSTALL A DEDUCT ♦^ Q � ROUND SHEET METAL DUCT: LIQUID TIGHT ON THE EXTERNAL SIDE OF THE DUCT SYSTEM. PROVIDE FlXTURESIEQUIPMENT FURNISHED 8Y OTHERS: THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION.CAP PIPE OPENINGS TO v, - SUPERVISION FOR ALL HOOD AND EXHAUST SYSTEM INSTALLATION.THE PROVIDE SPIRAL SEAM(ALL SIZES)OR SNAP LOCK(DUCT SIZES UP TO 10') THE"PENETRATOR'GREASE DUCT CLEAN-OUT ACCESS DOORS METER ON THE MAIN WATER SUPPLY TO THE SPACE IF REQUIRED BY PLUMBING CONTRACTOR SHALL PROVIDE UTILITY CONNECTIONS REQUIRED EXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONS HAVEU ¢ a HOOD PACKAGE WILL INCLUDE BUT NOT LIMITED TO A FIRE SUPPRESSION GALVANIZED STEEL COMPLYING WITH SMACNA STANDARDS.SPIRAL SEAM MANUFACTURED BY FLAME GARD,INC.(OR EQUIVALENT)AT EVERY LANDLORD. SUCH AS WATER,GAS,AIR,SUPPLIES,WASTE OUTLET,TRAPS,ECT.AT ALL BEEN MADE.PROCEED AS RAPIDLY AS CONSTRUCTION WILL PERMIT.SET W SYSTEM(PERMIT IF REQUIRED WILL BE PROVIDED BY THE GENERAL DUCTWORK SHALL HAVE SMACNA SEAM TYPE RL-1. CHANGE OF DIRECTION IN THE DUCT AND/OR EVERY 10 FEET WITH PLUMBING TYPE FIXTURES OR EQUIPMENT FURNISHED BY OWNER,GENERAL FIXTURES LEVEL AND IN PROPER ALIGNMENT.INSTALL SUPPLIES IN PROPER W �: O Z V - 12. GCS PLUMBING CONTRACTOR SHALL.CERTIFY THAT ALL PLUMBING IS CONTRACTOR),GAS VALVE,(TO BE INSTALLED BY GENERAL CONTRACTOR), MINIMUM OF 3 FEET OF CLEARANCE IN FRONT OF CLEAN-OUT. CONTRACTOR,FOOD SERVICE CONTRACTOR,EQUIPMENT SUPPLIER,ETC. ALIGNMENT WITH FIXTURES.INSTALL SILICONE SEALANT BETWEEN FIXTURES � _ ROOF CURBS(TO BE INSTALLED BY GENERAL CONTRACTOR), FLEXIBLE DUCT: MECHANICALLY ATTACHED TO BUILDING STRUCTURE. INCLUDED ARE STOP VALVES,ESCUTCHEONS,AND CHROME PLATED BRASS AND ADJACENT MATERIAL,FOR SANITARY JOINT,AND OMIT ESCUTCHEONS. 0 a) Gl Q EXHAUST r 1 FANS(TO BE INSTALLED BY GENERAL CONTRACTOR),MAKE UP AIR FANS(TO PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT(UL 181)WITH 1-112"THICK COMPOSITE GREASE DUCT ENCLOSURE ASSEMBLIES: 13. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL INCLUDE IN TUBING WITH COMPRESSION FITTINGS. O co 0: u (R-5 MIN.)1 PCF FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE PROVIDE FLEXIBLE BLANKET-TYPE INSULATION COMPOSED OF FIBER REPAIR EXISTING PLUMBING SYSTEM COMPONENTS DAMAGED BY e- Q C3 - BE INSTALLED BY GENERAL CONTRACTOR),ROOF CURBS FOR FANS AND THEIR PRICE A ONE YEAR WARRANTY FOR ALL COMPONENTS OF THE O N _ W W - COVER/VAPOR BARRIER FLEXIBLE DUCT SHALL MEET NEPA 90A WITH FLAME BLANKET ENCAPSULATED IN AN ALUMINUM FOIL SCRIM,PROVIDING A SEWER AND WASTE PIPING: CONSTRUCTION OPERATIONS AND RESTORE TO ORIGINAL CONDITIONS. - MAKE UP AIR UNIT(TO BE INSTALLED BY GENERAL CONTRACTOR).GENERAL NOODLES&COMPANY CONSTRUCTION PROJECT. ALL PARTS AND ALL a- - SPREAD UNDER 25,SMOKE DEVELOPED UNDER 50,AND SHALL BE RATED FOR NONCOMBUSTIBLE WRAP TO PROVIDE A VAPOR AND DUST BARRIER DUCT PROVIDE ALL DRAINS AND SEWERS WITHIN THE SPACE WITH CONNECTION TO © c CONTRACTOR WILL RECEIVE ALL OF OWNER SUPPLIED EQUIPMENT AND MINIMUM 2"W.G.PRESSURE AND 0 TO 250°F TEMPERATURE.PROVIDE WRAP SYSTEM SHALL HAVE FLAME SPREAD INDEX OF NOT MORE THAN 5 LABOR ARE COVERED FOR ALL REPAIRS ALL INCLUSIVE FOR 1 YEAR FROM THE EXISTING DRAINAGE SYSTEMS ON-SITE.SANITARY DRAINAGE PIPING ABOVE PRESSURE TEST: r P c a) WILL BE SOLELY RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN PRISTINE SCREW-OPERATED METAL ADJUSTABLE CLAMPING DEVICES.USE TWIST-LOCK AND SMOKE DEVELOPED INDEX NOT EXCEEDING 5,WHEN TESTED PER NOODLES&COMPANY OPENING DATE. FLOOR SHALL BE DWV PVC PLASTIC SCHEDULE 40 PIPING WITH SOLVENT WELD TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE,FOR FOUR(4) NEW CONDITION. CONICAL TAP COLLARS AT CONNECTIONS INTO SHEET METAL DUCTWORK. ASTM E-84 METHOD.INSULATION AND JACKET SHALL BE RATED FOR FITTINGS(WHERE PERMITTED BY CODFJLOCAL AUTHORITIES).WHERE REQUIRED HOURS MINIMUM.WHEN TESTING INDICATES MATERIALS OR WORKMANSHIP IS MAXIMUM EXTENDED LENGTH OF FLEXIBLE DUCT SHALL NOT EXCEED 6 FEET. OPERATING TEMPERATURES UP TO 2000'F.DUCT WRAP SYSTEM MUST 14. UNLESS OTHERWISE DIRECTED GCS PLUMBING CONTRACTOR IS REQUIRED BY AUTHORITIES HAVING JURISDICTION COPPER DWV PIPE WITH SOLDERED DEFICIENT,REPLACE OR REPAIR AS REQUIRED,AND REPEAT TEST UNTIL 5. IF REQUIRED BY NOODLES&COMPANY CONSTRUCTION MANAGER GENERAL COMPLY WITH ALL FIVE FIRE TESTS OF STANDARD ASTM E2336,GREASE TO PROVIDE AND INSTALL A BRADFORD-WHITE HOT WATER HEATER,WATER FITTINGS AND CONNECTIONS SHALL BE INSTALLED.SANITARY DRAINAGE PIPING STANDARDS ARE ACHIEVED. HEATER ALARM,MANIFOLD AND ALL ACCESSORIES. GC'S PLUMBING � -00-0 o o w CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ALL REFRIGERATION EXPOSED DUCTWORK DUCT ENCLOSURE SYSTEM,AND THE DUCT FIRESTOP SYSTEM SHALL BE BELOW FLOOR SHALL BE DWV Pi/G PLASTIC SCHEDULE 40 PIPING WITH SOLVENT V ^• PERMITS ALL INCLUSIVE. EXPOSED DUCTWORK SHALL BE CLEANED Of DEBRIS AND OIL,THEN WIPED ASTM E 814 CLASSIFIED.FABRICATE DUCT WRAP ENCLOSURE WITH(2) CONTRACTOR SHALL PROCURE WATER HEATER FROM NATIONAL WELD FITTINGS(WHERE PERMITTED BY CODEIL.00AL AUTHORITIES AND NATURAL.GAS PIPING SYSTEM: Mc s o. . DOWN WITH VINEGAR OR OTHER SURFACE PREPARING CHEMICAL.COORDINATE LAYERS OF DUCT WRAP TO PROVIDE 2-HOUR FIRE RATING.PROVIDE WHOLESALE SUPPLY. CONTACT ESTHER PADEN OR KATHY AT LANDLORD).WHERE REQUIRED BY AUTHORITIES HAVING JURISDICTION PROVIDE A COMPLETE GAS PIPING SYSTEM TO SERVE GAS FIRED HVAC *� _ ^•a - 6. MECHANICAL CONTRACTOR WILL PROVIDE ROUND SPIRAL DUCT IN DINING WITH ARCHITECTURAL PLANS IF DUCTWORK IS TO BE PAINTED. COMPOSITE GREASE DUCT FIRE PROTECTION INSULATION FROM ONE OF 1-888-444+6435 FOR INFORMATION. IN ALL CASES THE GCS PLUMBING SERVICE-WEIGHT HUB AND SPIGOT TYPE CAST-IRON WITH NEOPRENE GASKET EQUIPMENT,DOMESTIC WATER HEATERS AND EQUIPMENT FURNISHED BY D « I I ROOM,OVAL DUCT WILL NOT BE ALLOWED UNLESS SPECIFICALLY DIRECTED I THE FOLLOWING:THERMAL CERAMICS FIREMASTER FASTWRAP XL, JOINTS SHALL BE INSTALLED.ALL PIPING SHALL CONFORM TO ASTM A74,ASTM OTHERS,AS NOTED ON THE DRAWINGS.PROVIDE EITHER THREADED STEEL OR ou N b o 1; - CONTRACTOR SHALL PROVIDE INSTALL AND WARRANTY ALL NOODLES& IN WRITING BY NOODLES&COMPANY'S PROJECT ARCHITECT. DUCT SEALANT: UNIFRAX FYREWRAP 2.0 MAX. 888,AND CISP1301 STANDARDS.ALL DRAINAGE PIPING SHALL BE UNIFORMLY MALLEABLE IRON PIPE WITH MALLEABLE FITTINGS OR WELDED STEEL PROVIDE 13 ?4 C a m - COMPANY SELECTED,HOT WATER HEATING DEVICES ALL INCLUSIVE. - PROVIDE POLYMERIC RUBBER TYPE SEALANT FOR USE ON BOTH INTERIOR PITCHED,1/4"PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING ALL UNIONS,SHUT-OFF VALVES AND DIRT LEGS REQUIRED BY NFPA 54 AND r. ... o_•, � - 7. ALL DUCTS,BOTH SUPPLY AND RETURN,MUST BE INSULATED PER PROJECT LOCATED DUCTWORK AND DUCTWORK EXPOSED TO OUTDOOR CONDITIONS. TYPE 11 EXHAUST DUCTWORK 15. GCS PLUMBING CONTRACTOR IS REQUIRED TO VERIFY THAT THE ENTIRE CONDITIONS,OR INDICATED ON THE DRAWINGS. PVC SHALL NOT BE PERMITTED GOVERNING LOCAL CODES AND AT EACH GAS APPLIANCE CONNECTION. PLANS AND SPECIFICATIONS. SEALER SHALL HAVE HIGH BONDING STRENGTH FOR SURE,FIRST TIME SEALING FABRICATE TYPE 11 EXHAUST DUCTS OF 18 GAUGE ALUMINUM OR 18 GAUGE FOR EXPOSED SEWER AND WASTE PIPING. PROVIDE ALL TESTS,METERS INSPECTIONS,HANGERS AND EQUIPMENT 0 V r OR ' - SPACE WALL LAYOUT IS INDEED LAID OUT FIRST BEFORE UNDERGROUND ` «4V 8. GENERAL CONTRACTOR SHALL PROVIDE AND PAY FOR A COMPLETE TEST OF JOINTS IN LOW,MEDIUM,AND HIGH PRESSURE DUCT SYSTEMS.SEALER STAINLESS STEEL SEAMS SHALL BE CONTINUOUSLY WELDED LIQUID TIGHT. PLUMBING STARTS TO VERIFY THAT ALL WALLS AND EQUIPMENT WILL CONNECTIONS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM.PAINT ) s a W =SHALL BE HIGH 1N SOLID CONTENT.PROVIDE A TWO PART TAPE SEALING VENTS: EXPOSED GAS PIPING RUST RESISTANT YELLOW COLOR C aJ a AND BALANCE OF MECHANICAL SYSTEMS STATING THAT ALL SYSTEMS ARE SYSTEM,CONSISTING OF WOVEN FIBER TAPE IMPREGNATED WITH A GYPSUM MAKE-UP AIR UNIT: INDEED FIT PER PLAN.ANY CHANGE ORDER SUBMITTED FOR WALL PROVIDE A COMPLETE SYSTEM OF STANDARD WEIGHT CAST IRON NO-HUB VENT �� 0 0�0. y� ? - IN 100%COMPLIANCE WITH NOODLES&COMPANY PLANS,SPECIFICATIONS, MINERAL COMPOUND,AND A MODIFIED ACRYLIC/SILICONE ACTIVATOR THAT UNIT SHALL HAVE AN INTEGRAL DISCHARGE THERMOSTAT LINKED TO THE CHANGES FOR FIXTURES AND I OR FOR ANY EQUIPMENT TO FIT WILL NOT BE RISERS WHERE THE CEILING SPACE IS USED AS A RETURN AIR PLENUM OR USE DRAINAGE WASTE&VENT PIPE BEHIND KITCHEN HOOD: •� '=w;,`lI ba_�� AND NOODLES&COMPANY CONSTRUCTION MANAGER WRITTEN DIRECTIVES REACTS EXOTHERMICALLY WITH THE TAPE TWO PART TAPE SEALING SYSTEM INTERNAL CONTROLS.THE HEATER SHALL BE SET TO MAINTAIN DUCT SUPPLY APPROVED. DWV PLASTIC(WHERE PERMITTED BY CODE/LOCAL AUTHORITIES)WHERE THERE PIPE AND FITTINGS WITHIN WALLS BEHIND KITCHEN HOODS SHALL BE SERVICE = V o . a I . (REPORT WILL CONTAIN NO REMAINING,PUNCH,OR CORRECTIVE ITEMS). MUST BE RATED FOR BOTH INDOOR AND OUTDOOR APPLICATION.TAPE SHALL TEMPERATURE AT NO LESS THAN 65 DEG.F.(ADJ.). IS A DUCTED RETURN AIR SYSTEM.DO NOT USE DWV PLASTIC IN RETURN AIR WEIGHT HUBLESS CAST IRON WITH SLEEVE,SHIELD,AND DRAWBAND JOINTS � 1 n a °1GOO U THIS TEST AND BALANCE SHALL BE PERFORMED BY- NOT CONTAIN ASBESTOS. HIGH LIMIT SWITCH SET TO 180 DEG.F. 16. CELL CORE/FOAM CORE PIPING NOT PERMITTED FOR ANY REASON IN ANY PLENUM SPACES.THE VENT SYSTEM SHALL BE CARRIED THROUGH THE ROOF MEETING ASTM A-888 AND ASTM C-564. V Q a 1°'' IN INTAKE AIR SENSOR SET TO 10 DEG.F.(ADJ.)LOWER THAN DISCHARGE AIR APPLICATION. WITH APPROPRIATE FLASHING.ALL CAST IRON VENT PIPING SHALL CONFORM TO G 3C, SUPERIOR INC.(ERIC HOLCOMB)@(800)222-1819 AND(615)479-1578. DUCT INSULATION: SENSOR ASTM A74,ASTM AM,AND CISPI 301 STANDARDS.WHEN PVC IS USED ABOVE DRAIN,WASTE AND VENT PIPE AND PIPE FITTINGS(WHEN PERMITTED BY LOCAL jY (NON-EXPOSED SUPPLY AND RETURN DUCTWORK AND MAKE-UP AIR THE MAKE-UP AIR UNIT SHALL OPERATE WHENEVER THE HOOD IS SWITCHED ON GROUND THEY SHALL CONFORM TO ASTM D2665,ASTM D1785,AND ASTM F891 AUTHORITY AND LANDLORD). FINAL PAYMENT WILL NOT BE CONSIDERED UNTIL AND UNLESS TEST AND DUCTWORK)PROVIDE MINIMUM 2-1/2"(R-6 MIN.)THICK BLANKET TYPE AND STOP WHENEVER THE HOOD IS SWITCHED OFF. (LIMITED TO PIPE WITH A SDR OF 26 OR LESS).BELOW GRADE PVC SHALL - BALANCE REPORT IS 100%CLEAN AND ALL OUTSTANDING ISSUES HAVE FIBERGLASS INSULATION COMPLYING WITH ASTM C-5W.TYPE 11,WITH FACTORY CONFORM TO ASTM 01785,ASTM D2665,ASTM D3034(LIMITED TO TO PIPE WITH 1. ABS PLASTIC TYPE DWV PIPE: BEEN CORRECTED AND A REVISED,UPDATED REPORT HAS BEEN APPROVED APPLIED KRAFT BONDED TO ALUMINUM FOIL,REINFORCED WITH FIBERGLASS TEMPERATURE CONTROLS: SDR OF 26 OR LESS),AND ASTM F891(LIMITED TO PIPE WEIGHT OF SCHEDULE • PIPE: ASTM D 2661. _ 4 - _ i ACCEPTED BY NOODLES&COMPANY'S FACILITIES MANAGER AND THE VAPOR BARRIERIJACKET.JACKET SHALL CONFORM TO ASTM C-1136,TYPE Ii. PROVIDE PROGRAMMABLE THERMOSTATS WITH REMOTE TEMPERATURE 40), • FITTINGS: ABS DWV. GENERAL CONTRACTOR HAS POSTED THE FINAL TEST AND BALANCE SENSORS AND REMOTE HUMIDISTATS COMPATIBLE WITH ROOFTOP UNIT. I • FITTING PATTERN: ASTM D 3311. - REPORT ON USGN.TEST AND BALANCE REPORT MUST BE PROVIDED TO ROUND VOLUME DAMPERS: CONTROL WIRING SHALL BE INSTALLED IN CONDUIT, THERMOSTAT SHALL MEET INDIRECT&DIRECT DRAIN PIPING: • JOINTS: SOLVENT WELDED,ASTM D 2255. NOODLES&COMPANY AT CONSTRUCTION PUNCH-NO EXCEPTIONS WILL BE (DAMPERS SHALL BE PROVIDED AT ALL BRANCH DUCTS AND TAKE-OFFS FROM SETPOINT ADJUSTMENT FOR UNOCCUPIED MODE:HEATING DOWN TO 55 TYPE M COPPER TUBING UP TO 1'ID CONFORMING TO ASTM B42,ASTM B88,AND - TRUNK DUCTS): DEGREES AND COOLING UP TO 85 DEGREES.PROVIDE INTERLOCK CONTROL ASTM 8306.FOR 1Y."AND LARGER SIZES USE TYPE DWV COPPER TUBING AND Z. POLYVINYL CHLORIDE(PVC)PLASTIC TYPE DWV PIPE: - ALLOWED. PROVIDE MINIMUM 20 GAUGE GALVANIZED STEEL FRAME AND BLADES,MINIMUM WIRING BETWEEN HOOD EXHAUST FANS AND ROOFTOP UNITS. FITTINGS.WASTE PIPING SHALL HAVE STANDOFFS TO WALL OR EQUIPMENT AS • PIPE: ASTM D 2665. - 9. GENERAL CONTRACTOR AND MECHANICAL CONTRACTOR SHALL CERTIFY 3/8'SQUARE STEEL.AXLE,MOLDED SYNTHETIC BEARINGS,WITH LOCKING REQUIRED BY OWNER VERIFY WITH OWNER'S REPRESENTATIVE. • FITTINGS: ASTM D 2665. - POSITION REGULATOR.REGULATOR SHALL BE POSITIONED WITH SHEET METAL • FITTING PATTERN: ASTM D 3311. THAT ALL HVAC,ETC.,IS MECHANICALLY ATTACHED TO BUILDING BRACKET BEYOND DUCT COVERING.WHERE POSITIONING REGULATOR IS NOT CONDENSATE DRAIN PIPING: • JOINTS: SOLVENT WELDED,ASTM D 2564. Revisions STRUCTURE. ACCESSIBLE,PROVIDE COUPLING AND EXTENSION ROD WITH REGULATOR FOR ALL EXPOSED CONDENSATE PIPING SHALL BE TYPE M COPPER TUBING UP TO 1' . CPUC PLASTIC TYPE DWV PIPE: ISSUED FOR LANDLORD REVIEW Y' 3 10. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL INCLUDE IN CEILING OR WALL INSTALLATION,AS REQUIRED. ID CONFORMING TO ASTM B42,ASTM B88,AND ASTM 8306.FOR 1 AND LARGER . PIPE: ASTM F PE A 01-21-2015 THEIR PRICE A ONE YEAR WARRANTY FOR ALL COMPONENTS OF THE SIZES USE TYPE DWV COPPER TUBING AND FITTINGS.FOR CONDENSATE PIPING RECTANGULAR VOLUME DAMPERS: HIDDEN IN WALLS USE DWV PVC PLASTIC SCHEDULE 40 PIPE WITH SOLVENT • FITTINGS:ASTM F 2618. ISSUED FOR PERMIT NOODLES&COMPANY CONSTRUCTION PROJECT. ALL PARTS AND ALL (DAMPERS SHALL BE PROVIDED AT ALL BRANCH DUCTS AND TAKE-OFFS FROM WELD FITTINGS(WHERE PERMITTED BY CODE/LOCAL AUTHORITIES). • JOINTS: SOLVENT WELDED,ASTM F 439. /I 024)4.2015 - LABOR ARE COVERED FOR ALL REPAIRS ALL INCLUSIVE FOR 1 YEAR FROM TRUNK DUCTS): I Q NOODLES&COMPANY OPENING DATE. PROVIDE MINIMUM 16 GAUGE GALVANIZED STEEL CHANNEL FRAME,16 GAUGE I = 11. ALL TYPE II EXHAUST DUCT SHALL BE PROVIDED AND INSTALLED BY GALVANIZED STEEL BLADES,MINIMUM'W HEXAGONAL AXLE,BOLDED SYNTHETIC BEARINGS,WITH 318"SQUARE PLATED STEEL CONTROL SHAFT.LINKAGES SHALL MECHANICAL CONTRACTOR AT MECHANICAL CONTRACTORS COST. BE CONCEALED IN THE FRAME.OPERATING SHAFT SHALL EXTEND BEYOND 12. ALL TYPE 11 EXHAUST DUCT MUST BE WELDED AT ALL SEAMS ALL INCLUSIVE FRAME AND DUCT TO A LOCKING QUADRANT WITH ADJUSTABLE LEVER I A - THE DUCT MATERIAL SHALL BE EITHER ALUMINUM OR STAINLESS STEEL AS MAXIMUM BLADE WIDTH SHALL NOT EXCEED 6". p - V DIRECTED BY NOODLES&COMPANY CONSTRUCTION MANAGER. PEX TUBING SYSTEM SPECIFICATIONS ( PROVIDE ALTERNATE BID ) d - : 13. GCs MECHANICAL CONTRACTOR SHALL FURNISH TO THE OWNER ALL Q _ a. M OPERATING&MAINTENANCE MANUALS,RECORD DRAWINGS,TEST& 1. QUALITY ASSURANCE B. FITTINGS CONNECTIONS. BALANCE REPORT.CONTRACTOR SHALL COORDINATE WITH a. FITTINGS SHALL BE MANUFACTURED BY ZURN PIX INC,IDENTIFIED D. ENSURE NO GLUES,SOLVENTS SEALANTS OR CHEMICALS COME IN I%- A INSTALLER QUALIFICATIONS ' In MANUFACTURER REPRESENTATIVES FOR EMPLOYEE TRAINING BY THE LETTERS'QW OR Z' CONTACT WITH THE TUBING WITHOUT PRIOR PERMISSION FROM THE V_ REQUIREMENTS FOR ALL EQUIPMENT. a UTILIZE AN INSTALLER HAVING DEMONSTRATED EXPERIENCE ON b. MANUFACTURED IN ACCORDANCE WITH ASTM F1807 OR ASTM F2159 TUBING MANUFACTURER. u_ PROJECTS OF SIMILAR SIZE AND COMPLEXITY AND POSSESSES THE 0 14. GCs MECHANICAL CONTRACTOR SHALL SUBMIT COMPLIANCE CHECKLIST TO SKILLS AND KNOWLEDGE TO INSTALL A PEX POTABLE WATER ANDIOR COMPLY WITH ASTM F877 SYSTEM STANDARD AS IDENTIFIED . E. DO NOT EXPOSE PEX TUBING TO DIRECT SUNLIGHT FOR MORE THAN 6 N DISTRIBUTION SYSTEMON THE FITTING. MONTHS BUILDING OFFICIAL UPON SUBSTANTIAL COMPLETION OF PROJECT. . C. CRIMP SYSTEMS F. USE GROMMETS OR SLEEVES AT THE PENETRATION FOR PEX TUBING - Z`+ b. INSTALLER WILL UTILIZE SKILLED WORKERS HOLDING A TRADE COORDINATE WITH NOODLES CONSTRUCTION MANAGER a. QICKCLAMP:LISTED TO ASTM F877,IDENTIFIED AS A ZURN PEX INC, PASSING THROUGH METAL STUDS. Z QUALIFICATION LICENSE IC EQUIVALENT OR APPRENTICES UNDER QICKCLAMP BY THE"QICKCLAMP"AND"Q"MARKING G. USE A PEX MANUFACTURER RECOMMENDED FIRE STOP SEALANT 0 THE SUPERVISION OF A LICENSED TRADESPERSON. b. COPPER CRIMP RING:LISTED TO ASTM F1807 AND/OR ASTIM F877, MANUFACTURER Z. DELIVERY,STORAGE AND HANDLING BLACK IN COLOR AND IDENTIFIED AS A ZURN PEC INC,RING BY THE H. PROTECT PEX TUBING WITH SLEEVES WHERE ABRASION MAY OCCUR V LETTER"Q". 1. USE NAIL PLATES WHERE PEX TUBING PENETRATES WALL STUD OR - LL I A DELIVER MATERIALS IN MANUFACTURERS ORIGINAL,UNOPENED, D. TOOLS JOISTS AND HAS THE POTENTIAL FOR BEING STRUCK WITH A SCREW OR W W UNDAMAGED CONTAINERS WITH IDENTIFICATION LABELS INTACT UNTIL a. QICKCLAMP TOOLS SHALL BE SUPPLIED BY THE PEX TUBING NAIL. CL READY FOR INSTALLATION MANUFACTURER,IDENTIFIED BY THE NAME'ZURN"ON THE TOOL J. ALLOW SLACK OF APPROXIMATELY 1/8"PER FOOT OF TUBE LENGTH TO V B. STORE MATERIALS PROTECTED FROM EXPOSURE TO HARMFUL b. COPPER CRIMP RING TOOLS SHALL BE SUPPLIED BY THE PDC TUBING COMPENSATE FOR EXPANSION AND CONTRACTION. Z I ENVIRONMENTAL CONDITIONS AND AT TEMPERATURE AND HUMIDITY MANUFACTURER OR APPROVED BY THE PEX TUBING K MINIMUM HORIZONTAL SUPPORTS ARE TO BE INSTALLED NOT LESS ca CONDITIONS RECOMMENDED BY THE MANUFACTURER MANUFACTURER FOR USE. THAN 32 INCHES BETWEEN HANGERS IN ACCORDANCE WITH MODEL Signabire E. MANIFOLD PLUMBING CODES AND THE ZURN PEX PLUMBING INSTALLATION GUIDE 02/042015 a3• WARRANTY a. QICKPORT PREASSEMBLED MANIFOLD L. PRESSURIZE ZURN PEX TUBING IN ACCORDANCE WITH APPLICABLE Date 06 A WARRANTY SHALL COVER THE REPAIR OR REPLACEMENT OF PROPERLY b. COPPER MANIFOLD SYSTEM CODES OR IN THE ABSENCE OF APPLICABLE CODES,TEST PRESSURE 06/302016 - J INSTALLED TUBING AND FITTINGS PROVEN DEFECTIVE AS WELL AS c. CR MANIFOLD SHALL BE AT LEAST EQUAL TO NORMAL SYSTEM WORKING PRESSURE, Expiration Date U BUT NOT LESS THAN 40 PSI WATER OR AIR AND NOT GREATER THAN 225 - INCIDENTAL DAMAGES. d. MULTI PORT FITTINGS 1 PSI WATER,125 PSI AIR. EWWM Z B. WARRANTY PERIOD FOR PEX TUBING AND SUBSEQUENT SYSTEM SHALL e. COPPER MANIFOLD HEADER M, REFER TO OTHER SECTIONS LISTED IN RELATED SECTIONS PARAGRAPH - BE 25 YEAR NON-PRORATED WARRANTY AGAINST FAILURE DUE TO F. VALVES SHALL,BE OF THE PLASTIC OR METAL TYPE,MEETING THE HEREIN FOR RELATED PRODUCTS INSTALLATION. I AEREBY G7t MY SU A M10 PUWS AT BEEt1 PRE- IU DEFECT IN MATERIAL OR WORKMANSHIP,BEGINNING WITH THE DATE OF REQUIREMENTS OF ASTM F877,IDENTIFIED AS SUCH WITH THE FARED UN M MY SUPERV� COWP TiWnAl RAM OF MY IQ�IOMYI,EDGE,7}IE SAME COALY(MRH ALL RULES, W INSTALLATION. APPROPRIATE MARK ON THE PRODUCT. 7. FIELD QUALITY CONTROL REGULAnaNsAND OF01"�s of PORTUM,ORECaao I C. IT IS THE INSTALLERS RESPONSIBILITY TO AVOID MIXING FITTINGS RELATING TO STRUCTURES AND BUILDINGS. CL MANUFACTURED BY OTHERS AS IT WILL REDUCE THE OWNER'S 5. MANUFACTURER'S INSTRUCTIONS A SITE TESTS 21 WARRANTY. a. TO ENSURE SYSTEM INTEGRITY,PRESSURE TEST THE SYSTEM A. COMPLY WITH MANUFACTURERS PRODUCT DATA,INCLUDING PRODUCT ENGMIEER co TECHNICAL BULLETINS,TECHNICAL MEMO'S,INSTALLATION BEFORE COVERING TUBING IN CONCRETE AND AFTER OTHER 6 D. MATERIALS INSTRUCTIONS AND DESIGN DRAWINGS,INCLUDING;ZURN PEC TRADES HAVE WORKED IN THE VICINITY OF THE TUBING_ Drawn By Checked By 3 b. REPAIR AND REPLACE ANY PRODUCT THAT HAS BEEN DAMAGED -a A TUBING PLUMBING INSTALLATION GUIDE. ACCORDING TO MANUFACTURERS RECOMMENDATION CW SK a. a. CROSS-LINKED POLYETHYLENE(PFJ)MANUFACTURED BY THE PROTECTION - SILANE METHOD. 6. INSTALLATION B. Scale Date M a. PROTECT INSTALLED WORK FROM DAMAGE DUE TO SUBSEQUENT o) b. NON-BARRIER TYPE NONE 01-06-2015 . i14* . SHALL.HAVE A PRESSURE AND TEMPERATURE RATING OF 160 PSI AT A INSTALL ZURN PEC TUBING IN ACCORDANCE WITH TUBING CONSTRUCTION ACTIVITY ON THE SITE. _ 73°F,100PSI AT 180°F AND 80 AT 200°. MANUFACTURER'S RECOMMENDATIONS AND AS INDICATED IN THE ZURN Job NO. . rn PEX PLUMBING INSTALLATION GUIDE. 3 H. TUBING SHALL HAVE A MINIMUM OF 6 MONTHS W PROTECTION B. DO NOT INSTALL PEX TUBING WITHIN 6 INCHES OF GAS APPLIANCE .. 6 c. MANUFACTURED IN ACCORDANCE WITH ASTM F876 AND ASTM F877 OR WITHIN 12 INCHES OF ANY RECESSED LIGHT - 2115 - -0) _ AND TESTED FOR COMPLIANCE BY AN INDEPENDENT THIRD-PARTY C. DO NOT SOLDER WITHIN INCHES OF PEX TUBING IN THE SAME AGENCY. WATERLINE.MAKE SWEAT CONNECTIONS PRIOR TO MAKING PE)( Sheet No. - m P 5 6 7 8 RECEIVED _-- - --- ---- MAY 4 2015 A SEE 04/S401 I I I CITY OF TIGARD EX GL 8%4x30 EX GL 8%4x30 EX GL 3)x18 BUILDING DIVISiO RTU i 1,500 LBS ] ' I REVIKON SEE 03/S401 EX GL 3)6x18 00 �.; I F CONDENSING UNIT FOR ICE I ? I I MACHINE 200 LEISSEE 03/84)1 ! j 0 i ( F- Q l i 3 3 tn0 10L W I XX X CON ENSING X X X I M UNIT FOR I M EX GL 3)6x18 I z Q e J J WALK-IN J J J J COOLER I w w 250 LBS w w w w W U) f I I 0 SEE 04/S401 ! U zPJL M °� = N ; ; I , ;j I U) <> 0) 3 I I 3 0 C EX GL 8/x30 I EX GL 8/x30 EX GL 3Ysx18 J > O RTU 0 00 If Q 1,500 LBS 't I Fj; EF I :� I O O (D 04/8401 3 EF \ Z � F-- 325 LBS I i t •0co•o --; EX GL 3)6x18 F I t I _--__-__-_____-- _---. _-. __ �-�__--_________�!2 ____-____—.__—__-_-_---_--_-_ —--_ _ _-_.-- _ ___-__ __ ___________ -_______-__—_________- -_ _- _—.__—__--____—__.____-__ �_ j 32 LBS I--- I oco e. j I SEE 01/S401 3 1 ,$ C / "- Vol w,.,.. u Q I N '� N N I 1 d- 1 ' i i � I • 3 C X x x I X N I 06D X I X € E _ I ;Ilj � , _ L—A I M M 1 I M G_� / ( M VITT = 188 x ' i C J J I J i J I \ J I ! x I • t� t C� C' C' t CJ C� ----- .................aiKKC" x x MUA x I I I ; x - ---- X ±------ —*—I x - --------- a. o 040 W W W t I W e -- ------ -------- EX GL & 8 [ - - - -- - 3 1 I I � 1,000 LBS I'LSE 05 S401 r/ ' S 1 HOOD `�� j _;�� HOOD o �� i I I WT = 758# \� ' _ r WT = 758# -- — I I I + l I t SEE 01/S401 I EX GL 8%x30 I EX GL 8%x30 i I EX GL 3 x18 B 4 4 , ; I I ; Revisions ISSUED FOR LANDLORD REVIEW I 1 E !I - - ---------------; ! ( 101-21-2015 ISSUED FOR PERMIT .__ -- -------------------------- I 02-04-2015 LLJ I E fh I i t r I I I i I EX I GL 3)x18 I I � C [��;s _ •i •Kr Ll � 7M 11 e i —_— --- !' t I " Ff 3 a I+ I EX GL 3}jx18 j 4 00 I I I Is i I + 3 I I C 9 CD C—D CD C.9 E C9 J J J J E( CD 1 CD CD CD (( X X X X X X I X j X X X W W W W W I W j W 1 W W WE i( i 1 02-04-2015 I 1 DATE 12-31-2016 I i EXPIRATION DATE I 1 4 1 t ARCHITECT A EX 18x35 j I EX 18x35 EX 18x40 EX 18x35 IHEREBY CERTIFY THAT THESE PLANS HAVE BEENPRE- 6. I PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, REGULATIONS AND ORDINANCES OF PORTLAND,OREGON I RELATING TO STRUCTURES AND BUILDINGS. i — I ARCHITECT t. ---_•------------ — — — ——— — -----+ ---------- — --— Drawn By Checked By LS Date CRM I Scale 01-06-2015 ROOF FRAMING PLAN PLAN NOTES Job No. 1. ELEVATIONS f, ARE FROM NOMINAL RRST FLOOR ELEV +(0'-0"), SEE 14-2115 SCALE W = 1'-0" CIVIL DRAWINGS. 0"6"1' 2' 4' 8' Z SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCH DWGS FOR DIMENSIONS NOT SHOWN. Sheet No. PLAN NORTH 4. COORDINATE DECK OPENINGS — EXACT SIZE AND LOCATION, WITH MECH CONTRACTOR DWGS AND EQUIPMENT SUPPLIER. 8001 MEI 14314 t f ^ ^YR 3'b^1 NEW OPENING EXIST SHEATHING w4 DIAGONAL BRACE 6 °� N (TYP) 1 0 I 1 HOOD NEW (2) 2x6 w/SIMPSON LUS26-2 HANGER, TYP ---- 00 EXIST EXIST BEAM JOIST STEEL ROD HANGER ui - COORD w/ HOOD MFR O � F— Q TYPICAL ROOF OPENING FRAMING o5 HOOD BRACING PLANo1 W SCALE: Y4" = 1'-0" NOODLES-DET#034 S 4 SCALE: NOT TO SCALE NOODLES—DET003 S401 z Q L5x3x9(6 (LLV) w/ (2) )f Ox3" Q < SHEATHING LAG SCREWS (2) 2x8 BLOCKING < c (n G 0 U � BEAM (TYP) zi,06 = N U) Qrn WSW 2 >iRu BOLTs 0 � 0 � Y2"0 THREADED d ROD HANGER 000 af 0 VO� UNISTRUT P1000 z UNISTRUT ADJUSTABLE � a HINGE CONNECTION --- -- , u ATTACHMENT BY THE HOOD SUPPLIER I HOOD ea -------------I HOOD ATTACHMENT AT ROOF o2 E SCALE: Y4" = 1'-0" NOODLES_DET001 E S401 •�—�' NEW SHEATHING TO MATCH EXISTING w/8d NAIL 0 6" OC - PLYWOOD EDGE & 12" OC FIELD (AS REQUIRED FOR EXISTING OPENINGS) EXIST SHEATHING EXIST SHEATHING Revisions ISSUED FOR LANDLORD REVIEW 01-21-2015 ISSUED FOR PERMIT 02-04-2015 A NEW 2x6 w/SIMPSON W26 A HANGER, EACH END ® 2'-0" OC Q EXIST BEAMS 0 SECTION o3 SCALE: Y4" = 1'-0" NOODLES—DET008 S401 RTU OR MUA 400 BLOCKING 11fx16 GA STRAP w/ #10 DATE 02-04-2015 SCREWS ® 2'-0" OC (TYP) 12-31-2016 EXPIRATION DATE SIMPSON A35 ARCHITECT ® 2'-0" OC ROOF SHEATHING I HEREBY CERTIFY THATTHESE PLANS HAVE BEEN PRE- PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, REGULATIONS AND ORDINANCES OF PORTLAND,OREGON y RELATING TO STRUCTURES AND BUILDINGS. ARCHITECT NEW 2 2x8 UNDER THE RTU SIMPSON CS20 ( ) " Drawn By Checked By CURB w/ SIMPSON LUS26 ® 2-0 OC LS CRM EACH END (TYP) Scale Date 01-06-2015 EXIST BEAM Job No. SECTION04 14-2115 " " SCALE: �a = 1 —0 NOODLES_DET013 S401 Sheet No.S401 MEI14L s