Loading...
Plans (3) MFC2O15 - OO1 13 ii 3 � RECEIVEDo \\-------) ( MAR 4 2015 1 CITYOFTIGARll BUILDING DIVISION 29.-6" '+ 24'-6 - p` DUCT CONSTRUCTION DETAIL V fi 1 N TRANSVERSE REINFORCING (1) l In ill 1 CI 1 C I if t r -i p s C ll'H 11''`i AT JOINTS Iiil ,--i ,--i u" 2 1CCd= P.O.C.O Ali o P.O.C, B u ' ' O DRIVE SLIP DRIVE SLIP • E -- DtO 0 to In � DIMENSION OF SHEETMETAL MINIMUM REINFORCING - C/) I' LONGEST SIDE GAUGE ALL ANGLE SIZE AND MAXIMUM ( ( ( ) p \Iti PURLIN IN INCHES FOUR SIDES LONGITUDINAL SPACING ) —�) ) pp g�.os �\-- R—U-1 I"' I I - BETWEEN TRANSVERSE :� V� �` REINFORCED JOINTS &/OR INTERMEDIATE MIN. PLAIN S SLIP HEMMED S SLIP ALT. BAR SLIP BAR SLIP �. \p 4.78..-� ,,, a > -. - -1►-, g_O REINFORCING H. ^� ) 0 v M v IN. � 57 ^ 8 tn .D �' ❑ EXISTING I) F"'—, ,_, 5.64' 2_ RECOMMENDED RECOMMENDED RECOMMENDED RECOMMENDED •� C.) ,N 8/.... GAUGE GAUGE GAUGE GAUGE 03 S .N-1 4to 11 Pr I I I�M ''� N � �1i�t� UP THRU 12 26 NONE REQUIRED 1 26 26 24 24 x� 1 1 ' U W N ,n CI H 13 - 18 24 NONE REQUIRED 1 24 24 24 24 g C O O 19 - 30 24 Mr>: 1/8' @ 60 IN 1 24 24 24 i �� V 7r 31 - 45 22 1"X1'X 1/8' @ 60 IN 1 I 22 22 FI O s: I'" 1 (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED a (11 I . [ol,l illi 3 � � l i'�I I i i - ' IIj RECOMMENDED HANGER SIZES Q II; P FOR ROUND DUCT vz pc°{; SMACNA TABLE 5-2i 1 WAREH❑I_EE III Itti! UNION o a i 110 REGULATOR I F"0aw J NEN !� TEST PORT DUCT DIA. HANGER STRAP MAX. SPACING x7 o q z — '_ �� GAS VALVE 4, a 1.� DRIP VALVE UP THRU 26' ONE 1'X22 GA. 10 FEET i�•ji -o"' to ti Na�8 27' THRU 36' ONE 1'X18 GA. 10 FEET ' z r1 R EXISTING II 50 MBTU 37' THRU 50' ONE 1'X16 GA, 10 FEET r � a Q¢ UNIT HEATER GAS PIPING DETAIL rV zz¢ig z �� 3/40 O NTS 51' THRU 60' TWO 1'X18 GA. 10 FEET i U u x' D 1 z61 THRU 84' TWO 1'X16 GA. 10 FEET Z w_-// 1-10 NOTES: 8 g c� � SEE ALLOWABLE STRAP AND ROD LOADS IN TABLE 5-1 PAGE 5-8 OF SMACNA STANDARDS EXTERNAL LOADS ARE NOT ACCOUNTED FOR. o 0 SEE TABLE 2-2 FOR DUCT GAUGE SCHEDULE PAGE e x 2-22 OF SMACNA STANDARDS ®MECHANICAL cn SEE APPENDIX FOR DUCT METAL WEIGHT. N '/e•-r-o• CITY OP TIGARD REVIEWED FOR CO3E COMPLIANCE z OTC:App.ovel [tii- - /�� 1'ONi C w o Address: 1 (D 6--.o.) r7 Suite#: Fly. 4:3Tl,... JOk-'I(. Gas Piping 2 Lb Gas Piping: Longest Length Method as per Table C402,4(3) ID Longest Length Combined CFH Max Allowed CFH 1 121 95 836 r� 2 104 71 836 r� 3 121 167 836 4 60 48 1240 5 121 214 1530 < Q O f2,....„ p Outdoor Air Schedule Zone Equipment Occupancy Population Floor Area Outside Air Exhaust a 101 RTU 1 OFFICE SPACE 9 1718.991 185.174 0 102 RTU 2 OFFICE SPACE 3_ 682.358 69.926 0 Q O Gas Powered Roofto Units 14 MARK ID MANUFACT MODEL NO, New/Existing Tons CFM C❑❑LING HEATING /EIGHT POWER UTILIZATION NET MBH SEER EER INPUT MBH OUTPUT MBH AFUE VOLT/PH MCA MOCP RTU 1 YORK D7CG036N04046A EXISTING 0 0.000 12,50 0,00 0.00 0 0 0.00/0.00 0 208-230/3/60 0.0 0 RTU 2 YORK ZFO36NO8A2AAA NEW 3 1200 37.00 11,0013.00 100 80 0.80 612 208-230/3/60 18.9 25 PROJECT NO: J4650 OFFICE COPY Ml I OF I