Plans (4) MEC2 014 - 00577 2014 �, GAS PACK SCHEDULE ��yt ^^ , �' � �ll� C.) C FFFICIENCIES AIR FLOW ELECTRICAL o N COOLING GAS OPER SYMBOL QTY MFR MODEL AREA SERVED CONFIGURATION CAP. INPUT THERMAL SUPPLY RETURN MIN OSA WEIGHT NOTES � a_ o o N [TONS] [MBH] SEER / EER [%] [CFM] [CFM] [CFM] VOLTS / PH MCA MOCP [LBS] °'•C,�'0)r-to a c c'Zd•I o' w - ooco GP-1 1 CARRIER 48HCEA ZONE 1 VERTICAL DISCHARGE 3 115 15 / - 81% 1200 900 300 460 / 3 9.9 15 527 1, 2, 3 r--+ VC)01 LU-,t N Qi N�Ih GP-2 1 CARRIER 48HCEA ZONE 2 VERTICAL DISCHARGE 3 115 15 / - 81 / Q+ a o N- 1200 900 300 460 3 9.9 15 527 1, 2, 3 L n ..o GP-3 1 CARRIER 48HCEA ZONES 3 & 5 VERTICAL DISCHARGE 5 115 15.2 / - 81% 2000 1500 500 460 / 3 12.3 15 619 1, 2, 3 Q V)z o� o _ a in GP-4 1 CARRIER 48HCEA ZONE 4 VERTICAL DISCHARGE 4 115 15.6 / - 81% 1600 1200 400 460 / 3 10.8 15 609 1, 2, 3 �' v C oo X GP-5 1 CARRIER 48HCEA ZONES 6 & 8 VERTICAL DISCHARGE 5 115 15.2 / - 81% 2000 1500 500 460 / 3 12.3 15 619 1, 2, 3 W a E--i Q GP-6 1 CARRIER 48HCEA ZONE 7 VERTICAL DISCHARGE 3 115 15 / - 81% 1200 900 300 460 / 3 9.9 15 527 1 , 2, 3 GP-7 1 CARRIER 48HCEA ZONE 9 VERTICAL DISCHARGE 3 1 15 15 / - 81% 1200 900 300 460 / 3 9.9 15 527 1 , 2, 3 a NOTES: 1 . PROVIDE ROOF CURB AND HOLD-DOWN CLIPS = 2. DISCONNECT BY E.C. 3. PROVIDE JADE ECONOMIZER AND CO2 SENSOR GENERAL NOTES 1. NEW / REMODEL CONSTRUCTION CUTTING & PATCHING BY GENERAL CONTRACTOR. 12. SHEET METAL DUCT JOINTS SHALL BE SEALED WITH MASTIC. WHERE MASTIC IS USED TO SEAL OPENINGS GREATER THAN 1/4", A COMBINATION OF MASTIC AND MESH SHALL BE 2. INSTALLATION WILL COMPLY WITH 2010 OREGON MECHANICAL SPECIALTY CODE (GMSC), 2010 USED. OREGON STRUCTURAL SPECIALTY CODE (OSSC), 2010 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC) AND ASHRAE STANDARDS. 13. REPLACE EXISTING DUCTWORK IF THE TERMINAL CONNECTION USES MORE THAN 20' OF FLEXIBLE DUCTWORK. 3. LOAD CALCULATIONS WERE PERFORMED WITH AN APPROVED EQUIVALENT COMPUTATION PROCEDURE AND EQUIPMENT SIZING AND CAPACITY DOES NOT EXCEED THE LOADS 14. ALL MATERIALS & PRODUCTS USED WILL BE NEW UNLESS OTHERWISE DIRECTED BY THE CALCULATED AS PER SECTION 503.2 OF THE OEESC. OWNER. ALL EXISTING DUCTWORK, GRILLES & DIFFUSERS TO REMAIN, UNLESS OTHERWISE DIRECTED BY THE OWNER. 4. SUPPLY & RETURN AIR DUCTWORK TO BE LINED WITH 1" - 1-1/2# SA INSULATION FOR AT 15. COORDINATE DEMOLITION OF EXISTING HVAC SYSTEMS WITH GENERAL CONTRACTOR. LEAST 10' FROM AIR HANDLING EQUIPMENT, UNLESS NOTED OTHERWISE (INDOOR VS. DEMOLITION TO BE COMPLETED BY THE GENERAL CONTRACTOR. OUTDOOR). 5. NEW DUCTWORK TO BE INSTALLED USING SHEET METAL RUN OUTS IN ACCORDANCE WITH 16. ROOF CURBS TO BE FURNISHED AND SPOTTED BY HUNTER-DAVISSON. LEVELING AND SMACNA STANDARDS. ROOFING BY THE GENERAL CONTRACTOR. 6. INSULATE & SEAL DUCTS AND PLENUMS PER OEESC 503.2.7 & OSMC 603.9. TERMINAL 17. STRUCTURAL C;-,LCULATIONS FOR NEW ROOFTOP EQUIPMENT BY LICENSED STRUCTURAL CONNECTIONS WILL USE NOT MORE THAN 8' OF FLEXIBLE DUCTWORK. INSTALLATION OF FLEX ENGINEER. Co DUCT WILL BE HUNG PROPERLY TO PROVIDE PROPER AIRFLOW WITHOUT RESTRICTIONS. ALLC\2CURVED BLADEE COR SUPPLY AND RETURN AIR DUCTS AND PLENUMS SHALL BE INSULATED WITH A MINIMUM OF 18. NEW LAY-IN CE:UNG SUPPLY DIFFUSERS TO BE TITUS PCS (PERFORATED, ADJUSTABLE C\2R-5 INSULATION WHEN LOCATED IN UNCONDITIONED SPACES (CEILINGS AND ATTICS) ANDA E) OR EQUAL. MINIMUM OF R-8 INSULATION WHEN LOCATED OUTSIDE THE BUILDING. EXCEPTION: WHEN THE 19. PROGRAMMABLE ROOM THERMOSTATS TO BE MOUNTED 48" ABOVE FINISHED FLOOR. PER DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR SECTION 503.2.4 OF THE OEESC THERMOSTATS SHALL BE CAPABLE OF CONTROLLING THE PLENUM DOES NOT EXCEED 15 DEG. F. (RETURN DUCTS ABOVE CEILINGS). DUCT RUN OUTS TEMPERATURE BETWEEN 55'F AND 85'F WITH A DEADBAND OF 57. OFF-HOUR CONTROLS IN A CONDITIONED SPACE & EXHAUST DUCTS SHOULD BE UNINSULATED. SHALL BE ACCOMPLISHED USING A PROGRAMMABLE THERMOSTAT OR TIMECLOCK. OPTIMUM O 7. VOLUME DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN START CONTROLS SHALL BE ABLE TO VARY THE START-UP TIME OF THE SYSTEM TO JUST THE BRANCH DUCTS OR AT EACH INDIVIDUAL DUCT REGISTER, GRILLE OR DIFFUSER. IN MEET THE TEMPERATURE SET POINT AT THE TIME OF OCCUPANCY. PROVIDE A VANDAL ADDITION EACH VOLUME DAMPER OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT USED IN PROOF GUARD FOR THERMOSTATS LOCATED IN PUBLIC AREAS AS REQUIRED. Q BALANCING SHALL BE PROVIDED WITH ACCESS IN ACCORDANCE WITH SECTION 603.17 OF THE 20. PROVIDE MOTORIZED DAMPERS FOR OUTDOOR AIR SUPPLY AND EXHAUST SYSTEMS IN EXCESS OMSC. OF 300 CFM PER OEESC 503.2.4.5. EXCEPTIONS INCLUDE COMBUSTION AIR INTAKES, TYPE 1 8. SUPPLY AIR ECONOMIZERS SHALL BE PROVIDED ON EACH COOLING SYSTEM AND SHALL BE KITCHEN HOODS, COOLING EQUIPMENT RATED LESS THAN 54,000 BTU/HR AND HOOD VENTS H CAPABLE OF OPERATING AT 100 PERCENT OUTSIDE AIR, EVEN IF ADDITIONAL MECHANICAL WITH GRAVITY DAMPERS IN BUILDINGS LESS THAN 3 STORIES IN HEIGHT. COOLING IS REQUIRED TO MEET THE COOLING LOAD OF THE BUILDING. 21. OUTSIDE AIR Dl.�"PERS SHALL HAVE A MAXIMUM LEAKAGE RATE OF 20 CFM SQ.FT. @ 1.0" W EXCEPTIONS: / �i 8.1. COOLING EQUIPMENT LESS THAN 54 MBH TOTAL COOLING CAPACITY. THE TOTAL W.G. Q CAPACITY OF ALL SUCH UNITS WITH ECONOMIZERS SHALL NOT EXCEED 240 MBH PER BUILDING AREA SERVED BY ONE UTILITY METER OR SERVICE, OR 10 PERCENT OF ITS 22. DEMAND CONTROL VENTILATION (DCV) IS REQUIRED FOR SPACES LARGER THAN 500 SQ.FT. TOTAL INSTALLED COOLING CAPACITY, WHICHEVER IS GREATER. FOR SIMPLE S'i'-STEMS AND SPACES LARGER THAN 150 SQ.FT. FOR MULTIPLE ZONE SYSTEMS 8.2. SYSTEMS WHERE INTERNAL / EXTERNAL ZONE HEAT RECOVERY IS USED. WITH AN AVERAGE OCCUPANT LOAD OF 25 PEOPLE OR MORE PER 1000 SQ.FT. OF FLOOR 8.3. SYSTEMS USED TO COOL DEDICATED COMPUTER SERVER ROOMS, ELECTRONIC EQUIPMENT AREA AND SERVED BY SYSTEMS WITH ONE OR MORE OF THE FOLLOWING: ROOM OR TELECOM ROOM HAVING A WATER ECONOMIZER SYSTEM CAPABLE OF COOLING 22.1. AN AIR-SIDE ECONOMIZER; w W AUTOMATIC ..MODULATING CONTROL OF THE OUTDOOR AIR DAMPER; OR AIR BY DIRECT AND/OR INDIRECT EVAPORATION AND PROVIDING 100 PERCENT OF THE 22. EXPECTED SYSTEMS COOLING LOAD AT OUTSIDE AIR TEMPERATURES OF 45'F DRY BULB 22.3. A DESIGN OUTDOOR AIRFLOW GREATER THAN 3,000 CFM. O AND 407 WET BULB AND BELOW. 22.4. EXCEPTIONS: SYSTEMS WITH ENERGY RECOVERY COMPLYING WITH SECTION 503.2.6 OR 8.4. ECONOMIZER COOLING IS NOT REQUIRED FOR NEW COOLING SYSTEMS SERVING AN SPACES LESS THAN 750 SQ.FT. WHERE AN OCCUPANCY SENSOR TURNS THE FAN OFF, V 1 EXISTING DEDICATED COMPUTER SERVING ROOM, ELECTRONIC EQUIPMENT ROOM OR CLOSES THE VENTILATION DAMPER, OR CLOSES THE ZONE DAMPER WHEN THE SPACE IS TELECOM ROOM IN EXISTING BUILDINGS UP TO A TOTAL OF 600 MBH OF COOLING. UNOCCUPIED. 8.5. ECONOMIZER COOLING IS NOT REQUIRED FOR NEW COOLING SYSTEMS SERVING A NEW 23. COMPLEX MECHANICAL SUPPLY AIR SYSTEMS SERVING MULTIPLE ZONES SHALL BE VAV DEDICATED COMPUTER SERVING ROOM, ELECTRONIC EQUIPMENT ROOM OR TELECOM ROOM IN EXISTING BUILDINGS UP TO A TOTAL OF 240 MBH OF COOLING. SYSTEMS AND SHALL REDUCE PRIMARY AIR SUPPLY TO EACH ZONE TO ONE OF THE � 8.6. SYSTEMS USING CONDENSER HEAT RECOVERY, UP TO THE COOLING CAPACITY USED TO FOLLOWING WHEN THE ZONE TEMPERATURE IS INA 5 DEG. F. ZONE TEMPERATURE DEAD QBAND AFTER COOLING IS NO LONGER REQUIRED AND BEFORE REHEATING, RE-COOLING OR [� PROVIDE CONDENSER HEAT RECOVERY. MIXING TAKES PLACE: 9. FORCED AIR UNIT AND PACKAGED ELECTRIC EQUIPMENT WITH A TOTAL HEATING CAPACITY 23.1. TWENTY PEN.CENT OF THE MAXIMUM SUPPLY AIR TO EACH ZONE. 23.2. THREE HUNDRED CFM OR LESS WHERE THE MAXIMUM FLOW RATE IS LESS THAN 10 GREATER THAN 20 MBH SHALL HAVE A HEAT PUMP AS THE PRIMARY HEATING SOURCE. H PERCENT OF THE TOTAL FAN SYSTEM SUPPLY AIRFLOW RATE. 10. HEAT PUMPS HAVING SUPPLEMENTAL ELECTRIC RESISTANCE HEAT SHALL HAVE CONTROLS 23.3. THE MINIMUM VENTILATION REQUIREMENTS OF CHAPTER 4 OF THE OMSC UNLESS ON THAT, EXCEPT DURING DEFROST, PREVENT SUPPLEMENTARY HEAT OPERATION WHEN THE HEAT REQUIREINCREASIMEtITSNG ERE�UL SEINOACDECREAS RITICAL ZONES OVER�LLDOUTSIDETHE NAIR REQUIRIMUM EDBYTHE p PUMP CAN MEET THE HEATING LOAD. HVAC SYSTEM. AN INCREASE BEYOND MINIMUM VENTILATION RATES SHALL NOT BE v 11. SMOKE DETECTORS SHALL BE INSTALLED IN RETURN AIR SYSTEMS WITH A DESIGN CAPACITY APPLIED TO MORE THAN 20 PERCENT OF THE ZONES WITH REHEAT. GREATER THAN 2,000 CFM, IN THE RETURN DUCT OR PLENUM UPSTREAM OF ANY FILTERS, EXHAUST AIR CONNECTIONS, OUTDOOR AIR CONNECTIONS, OR DECONTAMINATION EQUIPMENT 24. OPERATION AND MAINTENANCE MANUAL(S) SHALL BE PROVIDED TO THE BUILDING -OWNER BY Ln AND APPLIANCES. SMOKE DETECTORS ARE ALSO REQUIRED AT EACH STORY OF RETURN AIR THE MECHANICAL CONTRACTOR IN ACCORDANCE WITH SECTION 503.2.9.3 OF THE OEESC. RISERS SERVING TWO OR MORE STORIES AND A DESIGN CAPACITY GREATER THAN 15,000 0 CFM. O c' EXCEPTIONS: 11.1. SMOKE DETECTORS ARE NOT REQUIRED WHERE AIR DISTRIBUTION SYSTEMS ARE OF 77GAM INCAPABLE OF SPREADING SMOKE BEYOND THE ENCLOSING WALLS, FLOORS AND CEILINGS REVIEWED FOR CODE COMP . ANC. OF THE ROOM OR SPACE IN WHICH THE SMOKE IS GENERATED. 0 11.2. SMOKE DETECTORS ARE NOT REQUIRED IN THE RETURN AIR SYSTEM WHERE ALL Approved: rn PORTIONS OF THE BUILDING SERVED BY THE AIR DISTRIBUTION SYSTEM ARE PROTECTED OTC: ro BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM. Pcrmit#• REVISIONS cn Q) Address: - C' � Byte • " Date: 2 ro L r) Q) L OFFICE COPY ru 0- 1 d J U)�� 0 o USE OF HUNTER-DAVISSON, INC. DRAWINGS, 7 L-n PECIFICATIONS AND OTHER DOCUMENTS c: DATE 10/15/2014 � These Drawings, Specifications and other documents are prepared FILE - ro by Hunter-Davis son, Inc. for this Project and unless otherwise JOB 14154 Ln provided, Hunter-Davisson, Inc. shall be deemed the author of o thesed DWN GL CHK JD2 documents and shall retain all common law, statutory and Q ri other reserved rights, including the copyright. The Owner shall be permitted to retain copies of the Hunter-Davisson, Inc. Drawings, Specifications or other documents for information and reference in Q connection with the Owner's use and occupancy of the Project. 0 The Hunter Davisson, Inc. Drawings, Specifications or other L- documents shall not be used by the Owner or others on other o L Lprojects, for addition to this Project or for completion of this M 0 0 Agreement, except by agreement in writing and with appropriate cy compensation to Hunter-Davisson, Inc. pry 1 OF 4 SHEETS V) 1 C O � U c 0 N p i O N N +%N tf') rQ� Qi C V)prj I (ND v 1 N CQRZ-f of w •�O O cD ~ �wd'N li �Wr-) c L aONn F--1 O O U p n0 tf D Uv ZO� O ry c +1 O�"X Fw �j U 00 0 Lai O ILQ c 0 A 24x8; DOWN 18x8 UF�1 D F F TYP 3 TYP ;2JJ A 24x8 UP -- 111 TYP 3 1 _ u 0 --- - -- --- H E B C 10"0.- 4-.12"0 2442202 x1`2 I I I IEJ 12x5 1 x6 j 10x6 10x6 10x6 COUBOOP°s ( --- I 10x6 44x12 UP j tL'i EE IV+� St � � 7-1 SINTIN DE OSIT - 8- ----- -- OF 1800 - ^I CUSTOMER SVC SHONEPM - --- -- - - -- --- - l.'M J 2 - - - --f - - - —{ - - - —}--24"�- - ------ C\2- 24x8 UP 1200 -- 20x10 C\2 TYP 2 � - , �,- 1 , 200 L LOBBY I I I 18x 10 I I 24x8 DOWN r'o 0 24x8 UP 0x8 _ f� ., -� SA DOWN FROM GP-7 Q 3 - - ------------ - -- - -- ---- - - - - -- - - -- -- - -- ---- - - �,O SA DOWN FROM GP-5 ° ( N SA DOWN FROM GP-6 H uF SA DOWN FROM GP-5 Lis, 24x8 DO N N W � 24x8 UP �i cv I 014 UI TYP7 5 I d, - 8 18x10 22x10 20x14 �Ox16 Q' �y 18x 10 T, L-0 28x,2 _ C w 24,x8--�P -- - -- - - - - -- - -- -- - - - 4x8 DOWN — 0 _ TYP 2 � 12x6 1;4x7 I I 24x8 UP I 10"oh�0 TYP 2 12x6 TYP 2 1400 12x6 12x6 14"0 d 20x7 I I -- 2 + L I I Q+ 10"o) I 14x10 18x8 12 6 TYP 4 2400 5 24x8 UP f� 20 -a -- - -- - - ---- - - TYP 4 2IY4P 0 DOWN 5h 1 24x101 UP I I 192318 WASHINGTON SQUARE TYP 4 92O0 SW WASHINGTON SQUARE OAD c aPHlc sca�E ►� TIGARD, OREGON 97223 ra 4,580SL TOT L GLLOOR cn� GR LLR PLAID w / AREA o o C\2 foCM0 1 BASEMENT PIAN 1ST FLOOR PLAN EXISTING rG HVAC REVISIONS e M 1 .1 1/8" = 1'-0" M 1.1 1/8" = 1'-0" / Ln 0) c ru L- r)r) Q� L (S U) Co USE OF HUNTER-DAVISSON, INC. DRAPINGS, GENERAL NOTES � DATE 10/15/2014 SPECIFICATIONS AND OTHER DOCUMENTS 1 ST FLOOR LAYOUT TO REMAIN THE SAME; SEE V) FILE - These Drawings, Specifications and other documents are prepared 1 �M 1 .2 FOR CONNECTION DETAILS FROM NEW ro b Hunter-Davisson, Inc. for this Project and unless otherwise Q JOB 14154 V) provided, Hunter-Davisson, Inc. shall be deemed the author of UNITS TO EXISTING DUCTWORK these documents and shall retain all common law, statutory and DWN GL CHK JD2 0 other reserved rights, including the copyright. The owner shall be PERMIT DRAWINGS TO SHOW CAD RENDERING OF > permitted to retain copies of the Hunter-Davisson, Inc. Drawings, Specifications or other documents for information and reference in 1 ST FLOOR DUCTWORK; SCHEMATIC SHOWN FOR Q connection with the Owner's use and occupancy of the Project. NOW 0The Hunter Davisson, Inc. Drawings, Specifications or other L documents shall not be used by the Owner or others on other o U- projects, for addition to this Project or for completion of this M 1 Agreement, except by agreement in writing and with appropriate compensation to Hunter-Davisson, Inc. 5 LL ry 2 OF 4 SHEETS rn • o c 0 1-1 U c O N _ Q o a) N +�N to I-(No o'Zdr r �W"tN Qo O NprjLo Q Z o— F -1 c OO�v X A 18x8 DOWN D E F DOWN o -o TYP 2 A B 18x8 P 2 GP-4 L a a 4 TON 26x 2 26x 1'2r- LJ a� _ _ I I 14x10 ❑ 14x10 \ _ -- S WALL REGIS ERS N Q I i FF� I I I S WALL REGIS�ERS OT N I _ L__A _ -- 1- -- -_26x110 , 18x12 r !JA ! I_ -- -- --- --r-� I -- I7-1 -- --- - ' --- - -- ------ - -- _ J 16x 12 L - -- --- --�'__� - - --- 1 UET0 ----- 26x10 - - 'L ---- r-r I --------- - r- -------------- --- ----- -- - --- 24x8 , OWN -` .}� ------- - =----- __� 4x CI 14x1 _ 1 1- � �. _______________ ________ _ �I� D FLOOR j------� I 2 8 OWN T`YP 2 I; E�- I I �1 I'T I TP 2 5SF 5, 1 5SF - N I U El �Cn I I I I GP-1 I I I l N 10 Ll LD �, L_ L . I 1 �.1 �'�_ _ 0GP-2 MT�ON 3 TON 14x14 SA DOWN FROM GP-7 I I i T � � 1 �� i �` J 3 TON 3 - -�, - - -- - co - ---- F - - -12x12 SA DOWN FROM GP-5 DN 16x8 18x 12 22x 12 28x 1 v 11 FLOOR C.NTf C - 14x20 SA DOWN FROM GP-6 FLOOR C NJ T1 I �_� I ! i �N 16x8 18x1 _ 22x12 �$Zc ( I I E STA USE[ � � I I E STA E 12 � � I I I ao T-- -- --------�ti..,}J i 18x12 I I I I ___ � 18x12 12x12 SA DOWN FROM GP-5 — J — L cD - - I I Io 26x10 01) I 16x8 op x 16 8 6' N DDI I I I L J N o +�2 LJ N X (o N °01 NX1 ( 2 10„ 3 ' � I I N Q 4 419 — — ------- — . �L�+� I I I J — - — — -- -- — 3 +� _ 16x8 248 DOWN TYP 2 24x8 DOWN - - T w E-1_ II _ TYP 2 7 � _� 1 l I I 01 0I I CD0 o � 24x8 DOWN ADDED OFFICES HOT IN SUMMER COLD ORIGINAL OFFICES 24x8 DOWN ADDED OFFICES - HOT IN SUMMER COLD ORIGINAL OFFICES TYP 4 IN WINTER r�' I I tYP 4 IN WINTER '' I s r 2ND F L R PLAN W AREA GFAPHIC SCALE .r z1 :y www rn p'�7 2ND F R PLAN W/ AREA GF APHIC SCALE o NORTHREF. [� NORTH raa� L 0 1 2ND FLOOR PLAN — DEMO /EXISTING HVAC 2 2ND FLOOR PLAN — NEW HVAC 1/8” _ 1'-0" 1'-0" 00 ro C�2 0 rn L LL REVISIONS KEYED NOTES 0 Cn 1 . RECONNECT NEW DUCTWORK TO EXISTING RISER SERVING ru 1 ST FLOOR GENERAL NOTES 2. NEW RETURN AIR GRILLE TO SERVE GP- 1 CT PERMIT DRAWINGS TO SHOW CAD RENDERING OF U) � 2ND FLOOR DUCTWORK; SCHEMATIC SHOWN FOR 3. REUSE EXISTING RETURN DUCTWORK THAT PREVIOUSLY 0 o USE OF HUNTER-DAVISSON, INC. DRAPINGS, SERVED THE MULTI—ZONE UNIT; CAP WHERE NECESSARY Cn SPECIFICATIONS AND OTHER DOCUMENTS NOW TO MATCH THE ZONE OF THE CORRESPONDING NEW GAS z DATE 10/15/2014 U) PACKThese Drawings, Specifications and other documents are prepared CONNECT NEW UNITS TO EXISTING DUCTWORK AS FILE — by Hunter-Davisson, Inc. for this Project and unless otherwise SHOWN Q JOB 14154 provided, Hunter-Davisson, Inc. shall be deemed the author of 4. EXISTING RETURN AIR RISER FROM 1ST FLOOR; CONNECT o these documents and shall retain all common law, statutory and NEW DUCTWORK TO RISER AND CAP UNUSED PORTION 0 DWN GL CHK JD2 rn Q) other reserved rights, including the copyright. The Owner shall be permitted to retain copies of the Hunter-Davisson, Inc. Drawings, Specifications or other documents for information and reference in Q connection with the Owner's use and occupancy of the Project. m The Hunter Davisson, Inc. Drawings, Specifications or other C L documents shall not be used by the Owner or others on other o Ii projects, for addition to this Project or for completion of this M 1 Agreement, except by agreement in writing and with appropriate 5 compensation to Hunter-Davisson, Inc. (L ry 3 OF 4 SHEETS . o O 1--1 U c 0 N p L O N Q) C'4 lf) O vi C V)Q7 (D OPENINGS FOR NEW ``� N o0 0l o GAS PACKS (TYP 2) NEW SHEET c L a-O N M METAL CAP E W�.-.o 0 0 (o,oLO v zov I y 0 LO X w j CO 00 LL- _5Q w L d rn �+ v a� ROOF EXISTING MULTI–ZONE UNIT CURB 2 SHEET METAL CAP - EAST SECTION E F 1 I =TON5 METER LOCATION? (VFY) 2LENGTH: (141' + 20') x 10% = 177' => 180' M1.3 OPENINGS FOR NEW E MULTIZONE UNIT BE GAS PACKS (TYP 2) REMOVED 1 GP-7 3 TON CYJ NEW SHEET ® [L-rr-. C\2 METAL CAP 20 RISER TO ROOF m o ® ®' 1 t". C\2 d) LI II I IIII IIIA � IIII IIII O ROOF IIII E SKYLIGH S I m Q I I I I IIII I IIII IIII ® � III IIII � I GP-2 IIII 3 SHEET METAL CAP - SOUTH SECTION ,III 3 TON (� �D II ► V GP-6 ! Q • ® ® 3 TON'; 3 M1.3YA N--I GP-1 3 TON O LGP-3 OPENINGS FOR NEW 5 TON GAS PACKS (TYP 2) O CD 5'-5„ 7,-6„ a co � I I I 01 2345 10 201 I 77 G APHIC SCALE O O .Cn O 4 SHEET METAL CAP - PLAN W � VIE CfEuD M1.3 ,/4" = ,'-o" ROOF PLAN - HVAC U_ 1 REVISIONS / Ln rn c ro ^^L fJ Q� L. U o KEYED NOTES 0 USE OF HUNTER-DAVISSON, INC. DRAWINGS, 0) SPECIFICATIONS AND OTHER DOCUMENTS —� DATE 10/15/2014 1 . FIELD—VERIFY EXACT ROOF OPENING DIMENSIONS BENEATH FILE - Ln These Drawings, Specifications and other documents are ru p prepared MULTI—ZONE UNI' TO BE REMOVED Q ,JOB 14154 by Hunter–Davisson, Inc. for this Project and unless otherwise Ln provided, Hunter–Davisson, Inc. shall be deemed the author of DWN GL CHK JD2 o d these documents and shall retain all common law, statutory anQ r, other reserved rights, including the copyright. The Owner shall be > permitted to retain copies of the Hunter–Davisson, Inc. Drawings, Specifications or other documents for information and reference in L Q connection with the Owner's use and occupancy of the Project. 1- 0� The Hunter Davisson, Inc. Drawings, Specifications or other L documents shall not be used by the Owner or others on other Li projects, for addition to this Project or for completion of this M 1 o 3 M Agreement, except by agreement in writing and with appropriate W compensation to Hunter–Davisson, Inc. LL ry 4OF 4 SHEETS