Plans (5)MEC2014-00494 MECHANICAL PLAN SCALE: 1/4" = 1'-O' LANDLORD NOTES I 1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND ESTABLISH A DISCREPANCY RESOLUTION PROCEDURE. 2. ALL SYSTEMS SHALL BE OPERATIONAL WHEN THE CONTRACTOR IS NOT ON THE PREMISES. 3. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD'S DESIGNATED ROOFER. 4. ALL WORK SHALL BE SCHEDULE WITH LANDLORD'S FIELD REPRESENTATIVE. DUCTWORK SYMBOLS SINGLE DOUBLE ABBR. DESCRIPTION �� (BUILDING DIVISION • RECTANGULAR DUCT t (602) 249-6311 • ROUND DUCT o� • 45 DEC. TAP: USE AT BRANCH DUCTS ONLY N • DUCT SPLIT W/DAMPER: USE AT ELBOWS AND TEES: PROPORTION DUCT AREAS BY CFM'S N • CURVED ELBOW -MIN. RADIUS R: 1.5 WIDTH o • 90 DEG. ELBOW WITH SINGLE RADIUS TURNING VANES �IIIII • FLEXIBLE DUCT CONNECTION O c- FD FIRE DAMPER r �r E_ BD BALANCING DAMPER (USE O.B.D. UNLESS NOTED OTHERWISE) L O O - - NEW TO EXISTING CONNECTION • SPIN -IN FLEX DUCT TAKE -OFF W/DAMPER • ® SA SUPPLY AIR • ® EXH EXHAUST AIR • z RA RETURN AIR • ®A OSA OUTSIDE AIR • TQ X T THERMOSTAT X: UNIT OR ZONE NUMBER S KEYED MECHANICAL NOTES I 1. 24x24, 10"0 NECK CD -1. BALANCE TO CFM NOTED. 2. 24x24, 8"0 NECK CD -1. BALANCE TO CFM NOTED. 3. 12x12, 8"0 NECK CD -2. BALANCE TO CFM NOTED. 4. 24x24, 22x22 NECK RG -1. 5. 12x12, 10x10 NECK RG -1. 6. NEW 16x6 TRANSFER AIR OPENING TO BE INSTALLED ABOVE SALES AREA CEILING. PROVIDE WITH 18x8, 16x6 NECK TG -1 ON STOCKROOM SIDE OF WALL. 7. NEW DUCT SMOKE DETECTOR TO SHUT DOWN UNIT UPON DETECTION OF SMOKE. 8. NEW 6"0 EXHAUST AIR DUCT TO CONNECT TO THE LANDLORD'S MAIN EXHAUST AIR DUCT. FIELD VERIFY EXACT POINT OF CONNECTION. 9. EXISTING TEMPERATURE SENSOR TO BE REUSED AND RELOCATED AS SHOWN. PROVIDE WITH NEW THERMOSTAT WIRE. FIELD VERIFY. 10. EXISTING LANDLORD'S MAIN SUPPLY AIR DUCT TO REMAIN AS IS. FIELD VERIFY. 11. EXISTING 14"0 SUPPLY AIR INLET DUCT TO BE REUSED. FIELD VERIFY EXACT LOCATION AND SIZE. 12. NEW VAV BOX (VAV-1) TO REPLACE REMOVED EXISTING FAN POWERED VARIABLE AIR VOLUME BOX. FIELD VERIFY. 13. EXISTING VARIABLE AIR VOLUME BOX TO BE ABANDON IN PLACE. CAP EXISTING SUPPLY AIR DUCT AIR TIGHT. FIELD VERIFY. 14. EXISTING SUPPLY AIR INLET DUCT TO REMAIN AS IS. FIELD VERIFY. 15. UNDERCUT DOOR 1". 3 16. CONNECT EXISTING 14"0 INLET DUCT TO PRIMARY INLET OPENING. FIELD VERIFY. RECEIVED rIt NAmr; SEP 10 2014 N E (~ o CITYOFTIGARD Ln 00 Z' (BUILDING DIVISION W aJ pH14-035 t (602) 249-6311 X N �a Q o� N N o Ln M mrn y N O c- to l� A E_ N (� L O O M s M 0) r4 z N r.1 N O Ln tG -_ to REVISIONS: A LANDLORD COMMENTS 7-22-14 ZL DESIGN REVISIONS 7-23-14 A CONSTRUCTION ISSUE 8-14-14 CITY OF TIGARD REVUMM FOR CO B CO SEAL APProredt � OTCs t I Peemit th GJM� �O i,_i - K. Addreem l 7%/ 4A �n 55�_ <v� 183 -p Suite r Suite iiik'. 0 -_ OREGON gy; Dam (Ok— o o" o OQ OFFICE COPY 7-17-2014 DRAWN BY: NP MECHANICAL, INC. rIt NAmr; •CONSULTING ENGINEERS PH14-035-M1 1717 W. NORTHERN AVE. - SUITE 116 PROJECT NUMBER: PHOENIX. ARIZONA 85021 pH14-035 • (602) 249-6311 PROJECT NO. ^ 14080 (� C cu C) r.1 ._ cr m r4 to � Ln m 0 Ln i dlN 2 00 Ua > 0) to F— REVISIONS: A LANDLORD COMMENTS 7-22-14 ZL DESIGN REVISIONS 7-23-14 A CONSTRUCTION ISSUE 8-14-14 CITY OF TIGARD REVUMM FOR CO B CO SEAL APProredt � OTCs t I Peemit th GJM� �O i,_i - K. Addreem l 7%/ 4A �n 55�_ <v� 183 -p Suite r Suite iiik'. 0 -_ OREGON gy; Dam (Ok— o o" o OQ OFFICE COPY 7-17-2014 DRAWN BY: NP MECHANICAL, INC. rIt NAmr; •CONSULTING ENGINEERS PH14-035-M1 1717 W. NORTHERN AVE. - SUITE 116 PROJECT NUMBER: PHOENIX. ARIZONA 85021 pH14-035 • (602) 249-6311 PROJECT NO. ^ 14080 P�� A B A 5 DEG OR LESS AIR B AIR AIR FLO 15 DEG OR LES 30 DE a FLOW TRANSFORMATION EXPANSION CONTRACTION TURNING VANE D TURNING VANES 2D D 2/3D THREE 90ELBOW TURNING VANES 2/3D I D I 45 ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS D a 2w z CL D ozz TURNING VANES N r r a z z SUPPLY OR RETURN WYE D1+D (RECTANGULAR DUCT) AIR , 3 FLOW a o D1 I' _I 1/2 0 [T D J 3/4 D 90 ELBOW TAKE -OFF RETURN AIR BRANCH USE ONLY IN AREAS FULL RADIUS ELBOW FITTING WHERE SPACE IS LMTED TAKE -OFF 1/2„ W W 45 (4" MIN.) BRANCH DUCT (RECTANGULAR DUCT) DUCTWORK DETAILS TAPE AROUND SNUGGLY Z ROUND S.A. WRAPS PRIOR TO INSTALLING 2" DUCTWORK ABOVE CEILING. LINE STRAP SEE PLAN FOR DUCT SIZE. FLEXIBLE DUCT IDESCRIPTION MAX. 4'-0" LENGTH f� MATERIAL 1" WIDE x 20 GA. STRAP W/ FRAME TIGHTENING SCREW GYP BOARD CEILING SECURE STRAP W/ SHEET CD -1 METAL SCREWS 3' O.C. MAX. TITUS TDC STEEL 24"x24" "TITUS" TRM-RAPID MOUNT FRAME FLANGE 24"x24" "TITUS" MODEL # TDC, OPPOSED BLADE ROUND NECK (SEE SHEET M1 CD -2 FOR NECK SIZE) BORDER TYPE TITUS 3 -LAY -IN DIFFUSER SQUARE SUPPLY AIR DIFFUSER DETAIL EXHAUST FAN SCHEDULE GRILLE, REGISTER, AND DIFFUSER SCHEDULE OUTSIDE AIR REQUIREMENTS PER TABLE 403.3 IMC, 2006. MARK AREA SERVED MANUFACTURER MARK IDESCRIPTION MANUFACTURER MODEL MATERIAL MODULE FRAME FRONT BLADES DAMPER FINISH CD -1 CEILING DIFFUSER TITUS TDC STEEL 24x24 FLANGE 4 -WAY OPPOSED BLADE 580.2 CD -2 CEILING DIFFUSER TITUS TDC STEEL 12x12 FLANGE 4 -WAY OPPOSED BLADE m0) RG -1 RETURN GRILLE TITUS 23RL STEEL SEE PLAN FLANGE - NONE Vf TG -1 I TRANSFER GRILLE TITUS 350RL STEEL 18x8 FLANGE LONG NONE N O * NOTE: FIELD PAINT ALL DIFFUSERS AND GRILLES. COLOR BY ARCHITECT. PROVIDE RAPID MOUNT FRAME "TITUS" MODEL TRM FOR ALL DIFFUSERS LOCATED IN GYP. BOARD CEILINGS. EXHAUST FAN SCHEDULE MARK OUTSIDE AIR REQUIREMENTS PER TABLE 403.3 IMC, 2006. MARK AREA SERVED MANUFACTURER MODEL CFM �EWC•) MOTOR BAROMETRIC B DAMPERIC DRIVE HP SQ. FT. EF -1 TOILET ROOM GREENHECK SP-8110FL 100 0.25" 80 W. 120/1 BACKDRAFT DAMPER DIRECT TOTAL REQUIRED CFM 580.2 TOTAL CFM REQUIRED = 580.2 TOTAL CFM PROVIDED = 585 BALANCE OSA AS FOLLOWS: O REQUIRED FRESH AIR SHALL BE INTRODUCED VIA EXISTING VAV BOX. Ln T NOTE: 1. VERIFY VOLTAGE/ PHASE WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. m0) � 0 OUTSIDE AIR CALCULATION MARK OUTSIDE AIR REQUIREMENTS PER TABLE 403.3 IMC, 2006. MODEL INLET SIZE AREA MULTIPLIER REQ'D. CFM SALES 1803 X 0.3 CFM/ S.F. 540.9 40MC30OL514 SQ. FT. 2500 585 1000 12 208 1 5.0 / / 208 3 / 262 X 0.15 CFM/ S.F. O �- STOCK SQ. FT. L 39.3 TOTAL REQUIRED CFM 580.2 TOTAL CFM REQUIRED = 580.2 TOTAL CFM PROVIDED = 585 BALANCE OSA AS FOLLOWS: O REQUIRED FRESH AIR SHALL BE INTRODUCED VIA EXISTING VAV BOX. Ln T M FLEXIBLE DUCT CONNECTION NTS I 2 FLEXIBLE DUCT. SEE PLAN FOR SIZE 'DUCT OR EQUIP. COLLAR II ISI_ --TAPE AROUND LINEPSTRAP R ON�INSTALLING 1" WIDEx20 GA. STRAP W/ TIGHTENING SCREW. OUTER EDGE OF COLLAR SECURE STRAP W/SHEET METAL SCREWS 3' O.C. MAX. L 1/8" MAX. GAP FAN POWERED VARIABLE VOLUME BOX MARK MANUFACTURER MODEL INLET SIZE PRIMARY CFMI FAN HEATER REMARKS MAX. MIN. CFM HP I V/0 KW V/0 VAV-1 CARRIER 40MC30OL514 14"0 2500 585 1000 12 208 1 5.0 / / 208 3 / ELECTRONIC CONTROLS. COORDINATE W/ L.L. MECHANICAL GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION, AND LANDLORD'S CRITERIA. 2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY; AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK. 4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. 5. DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS; AND MANUAL VOLUME DAMPERS IN ALL BRANCHES, SPLITTER DAMPERS, AIR EQUALIZERS, EXTRACTORS, AND SIMILAR DEVICES WHEREVER NECESSARY TO PROPERLY BALANCE THE SYSTEM AND PRODUCE A QUIET AND DRAFTLESS OPERATION. 6. DUCTWORK SHALL BE GALVANIZED SHEET METAL OF LOCK FORMING QUALITY. 24 GAUGE UP TO 30", 22 GAUGE - 30" AND OVER. ALTERNATE: STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK. 24 GAUGE UP TO 36"0, 22 GAUGE -36" TO 50". FIRST 15 FT. OF DUCT FROM EQUIPMENT SHALL BE LINED 1" HEAVY DENSITY ACOUSTICAL INSULATION. 7. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX "M -KE" WITH ONE INCH EXTERNAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L. AND 90A LISTED, SHALL BE EQUIPPED WITH DAMPER -EXTRACTOR AT THE SHEETMETAL DUCT AND CIRCULAR COLLAR AT THE DIFFUSER, MECHANICALLY SECURED. 8. FLEXIBLE DUCTWORK SHALL NOT EXCEED 6 FEET IN LENGTH; BENDS SHALL NOT RESTRICT THE INSIDE CROSS-SECTIONAL AREA OF THE DUCT; AND CONNECTION SHALL BE MADE AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY. 9. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 10. PROVIDE A READY -TO -USE SYSTEM WITH ALL WORK GUARANTEED IN WRITING AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM TURN OVER TO OWNER. 11. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 OR GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5'-0" DUCTWORK MATERIALS SHALL BE PER INTERNATIONAL MECHANICAL CODE, 2006. 12. PROVIDE AS PART OF THE MECHANICAL CONTRACT SERVICES OF AN INDEPENDENT AIR /WATER BALANCING CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL. SUBMIT 3 COPIES OF THE BALANCE REPORT TO ARCHITECT/OWNER. SUBMIT 1 COPY OF THE BALANCE REPORT TO THE LANDLORD. HVAC NOTES 1. ALL WORK TO BE AS PER THE L.L. SPECS, ALL LOCAL CODES, RULES AND REGULATIONS. ALL WORK TO BE AS PER ASHRAE AND SMACNA GUIDELINES. 2. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDELINES. 3. PROVIDE NECESSARY TURNING VANES, SPLITTER DAMPERS, VOLUME EXTRACTORS AND OTHER FEATURES NEEDED FOR A SMOOTH AND CONTROLLED FLOW OF AIR. 4. LOCATIONS SHOWN OF HVAC EQUIPMENT AND DUCTS ARE SCHEMATIC ONLY. VERIFY STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OF THESE COMPONENTS. IF MORE SUPPORTS ARE NEEDED FOR HVAC EQUIPMENT, COORDINATE WITH THE ARCHITECT. 5. PROVIDE PROPER DUCT TRANSITIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOF PENETRATIONS, IF ANY, TO BE MADE AS PER LANDLORD SPECS. VERIFY DETAILS WITH LANDLORD. 6. PROVIDE AND INSTALL THERMOSTATS AT LOCATIONS AS DIRECTED BY THE ARCHITECT. 7. COORDINATE ACTUAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES WITH CEILING DETAILS AND OTHER FEATURES SUCH AS LIGHTING FIXTURES ETC. THAT MAY AFFECT PLACEMENT OF THE HVAC SYSTEM COMPONENTS. 8. PROVIDE APPROVED FIRE DAMPERS WITH ACCESS PANELS AT ALL PENETRATIONS OF FIRE RATED PARTITIONS, WALLS AND CEILINGS AS REQUIRED BY CODE. 9. INSULATE NECK, THROATS AND COLLARS OF SUPPLY OUTLETS ABOVE CEILING. 10. ALL ROOF PENETRATIONS MADE BY THE TENANT'S GENERAL CONTRACTOR MUST CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. WEATHERPROOFING OF ANY INSTALLATION BY TENANT MUST BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR, AND TENANT'S GENERAL CONTRACTOR SHALL PAY ALL SUCH COSTS. 11. TENANT'S GENERAL CONTRACTOR WILL BE REQUIRED TO PROVIDE TEMPORARY WEATHERPROOFING FOR ALL ROOF PENETRATIONS, UNTIL LANDLORD'S ROOFING CONTRACTOR HAS MADE THE FINAL PATCH. NOTE: PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF ANY LANDLORD PROVIDED, OR EXISTING, OUTSIDE AIR INTAKES THROUGH ROOF, LANDLORD PROVIDED CHILLED/HOT WATER PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, CONDENSATE LINE MAINS, ETC. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES. NP MECHANICAL, INC. •CONSULTING ENGINEERS 1717 W. NORTHERN AVE. - SUITE 116 1 PHOENK ARIZONA 85021 • '1`17 PROJECT NO.14080 RECEIVE'P SEP I 0 X914 CITYOFTIGARD nNi E BUILDING DIVISION L vw O O1 rpk Q t X a1 lmw C O �- G. L _W O Ln T m0) � O N O to lC E0 E Vf � O +' O M � M 0) Z N C14 N O _ 0 -_ F- -�00 Ln m r C N C G V1 00 0 0 a 0 2L.L7. N F- REVISIONS: Z a N Lu J D Lu 1 1 I 1 I 1 1 0 LANDLORD COMMENTS 7-22-14 0 DESIGN REVISIONS 7-23-14 0 CONSTRUCTION ISSUE 8-14-14 SEAL, . n F � N o 18372 F� OREGON 1b 3t do �O GAF C. PPN�e�I�RI�A DATE: 7-17-2014 DRAWN BY: FILE NAME: PH14-035-M2 PROJECT NUMBER: PH14-035 Aft vw rpk -0 lmw fp o � C/1 C N N m lll� cn _ 0 -�00 Ln m r C N C G V1 00 a Ln 0) 2L.L7. N F- REVISIONS: 0 LANDLORD COMMENTS 7-22-14 0 DESIGN REVISIONS 7-23-14 0 CONSTRUCTION ISSUE 8-14-14 SEAL, . n F � N o 18372 F� OREGON 1b 3t do �O GAF C. PPN�e�I�RI�A DATE: 7-17-2014 DRAWN BY: FILE NAME: PH14-035-M2 PROJECT NUMBER: PH14-035