Plans (19)
M EC2014- 00403 M MECHANICAL SYMBOL LIST GENERAL NOTES W = MOO DUCTWORK 1. PROVIDE AND INSTALL 1y" INSULATION ON REFRIGERANT o M CD CEILING DIFFUSER PIPING. ®} 2. PROVIDE AND INSTALL R-5 MINIMUM DUCT INSULATION ON ® SUPPLY OR OUTSIDE AIR CND CONDENSATE DRAIN ALL SUPPLY DUCTS. RETURN DUCTS ARE NOT INSULATED CFM CUBIC FEET PER MINUTE UNLESS OTHERWISE NOTED. RETURN AIR COP COEFFICIENT OF PERFORMANCE 3. SEAL ALL DUCT SEAMS WITH MASTIC OR FOIL BACKED DUCT TAPE. ® ® EXHAUST AIR CONT. CONTINUATION 4. PROVIDE O&M MANUALS TO OWNER ON ALL MECHANICAL CU CONDENSING UNIT EQUIPMENT. R© 1 ROOM THERMOSTAT 5. AIR BALANCE TO+10% OR -5% OF INDICATED FLOWS TO D DROP EACH GRILLE/DIFFUSER. ova QS SENSOR DB DECIBEL 6. PROVIDE START-UP ON ALL EQUIPMENT PER DB DRY BULB MANUFACTURERS RECOMMENDATION. AC-1 EQUIPMENT IDENTIFICATION 7. THERMOSTATS TO BE 7-DAY PROGRAMMABLE WITH DIA DIAMETER 5-DEGREE DEADBAND AND NIGHT SET-BACK CAPABILITY. lift qz CD-1100 DIFFUSER OR GRILLE IDENTIFICATION DX DIRECT EXPANSION 8. PROVIDE ELECTRIC STRIP HEAT LOCKOUT ON ALL HEAT • 6"0-4 EAT ENTERING AIR TEMPERATURE PUMPS AND SET AT 32 DEGREES. DAMPERS EDH ELECTRIC DUCT HEATER VOLUME DAMPER EER ENERGY EFFICIENCY RATING EF EXHAUST FAN O FIRE DAMPER EEF EFFICIENT FD FIRE/SMOKE DAMPER EL ELEVATION FSD ELEC ELECTRICAL I SMOKE DAMPER SD EXH EXHAUST MOTORIZED DAMPER F FAHRENHEIT Jet FD FIRE DAMPER DUCTWORK FITTINGS FLA FULL LOAD AMPS Job dumber: Contact:nm FT FEET 14-0239 II MITERED ELBOW WITH Design y: Telephone: TURNING VANES HP HEAT PUMP 9MMYis (503)363-2334 THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR HP HORSEPOWER DISCLOSED TO OTHERS FOR PROCUREMENT OTHEROR PURPOSE, EXCEPT RADIUSED ELBOW OTHERWISE AUTHORIZED BY CONTRACT, HTR HEATER WITHOUT PERMISSION OF JET INDUSTRIES,INC. 1935 SILVERTON RD. SALEM,OR 97301 RECTANGULAR MAIN WITH IE INVERT ELEVATION (503)363-2334 FAX:(503)364.2488 OR CCB#' C226;CA CCI 475267 ROUND BRANCH ALL REPRODUCTIONS SHALL BEAR IN INCHES THIS NOTICE. RECTANGULAR MAIN WITH KW KILOWATT RECTANGULAR BRANCH LAT LEAVING AIR TEMPERATURE ROUND MAIN REDUCING WITH LBS. POUNDS ROUND BRANCH MA MIXED AIR CONCENTRIC SQUARE TO MAX MAXIMUM ROUND MBH THOUSAND BTU'S PER HOUR ECCENTRIC TRANSITION, RECTANGULAR OR ROUND MD MOTORIZED DAMPER MH MOUNTING HEIGHT NON-SYMMETRICAL WYE MIN MINIMUM SYMMETRICAL WYE N/A NOT APPLICABLE NTS NOT TO SCALE RECTANGULAR DUCT RISER OA OUTSIDE AIR ROUND DUCT RISER OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER ;;•;;; RECTANGULAR DUCT DROP PH PHASE _! ROUND DUCT DROP QTY QUANTITY RA RETURN AIR RECTANGULAR OFFSET LESS THAN 15° RET RETURN i RPM REVOLUTIONS PER MINUTE REVISIONS: RECTANGULAR OFFSET MORE THAN 15° SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATING ROUND WYE SF SQUARE FEET ROUND DUCT WITH ROUND SH SENSIBLE HEAT BRANCH SP STATIC PRESSURE CONCENTRIC TRANSITION, TEMP TEMPERATURE RECTANGULAR OR ROUND PROF UH UNIT HEATER c�� G'NEFss��2 ACCOUSTICALLY LINED V VOLT Qz 5 9P 9 DUCT"INSIDE DIMENSION (OUTSIDE DIMENSION)" VD VOLUME DAMPER (HAND OPERATOR) W WATT SHEET INDEX G ABBREVIATIONS W/ WITH M0.1 LEGEND/SHEETS - HVAC iyNN S-\ A/C AIR CONDITION(ED) WB WET BULB EXPIRES: 06-30-2016 PROJECT TITLE: AD ACCESS DOOR W/O WITHOUT AFF ABOVE FINISHED FLOOR BDD BACKDRAFT DAMPER O C� F-+ I CITY ON TICARD ItEV3L�tX/ED FOR COD COMPLIA,NCI U _ APProwd: j Q OTC: ] N Permit#: �,'� _ / ��. . _ + Address: Suite#: ~ Date: LA By: � � w Approved plans W shall be on job site. W Q C o Q < \ O w w a OFFICE COPY > x N W O o SHEET TITLE: LDATE: SHEET: C] w � Q PROJECT z Mo. I m . NOTES Z "Coo I 1 4"0 EXHAUST DUCTS UP AND CONTINUE ON SHEET M2.2a. O ~ O 2Y2"COMBUSTION AIR AND VENT UP IN WALL. CONTINUE ON o O o U _ — SHEET M2.2a. —I — — — — — — — _........ .:::................ � a'CONDENSATE DRAIN TO HUB DRAIN. COORDINATE � ct Q 3 ROUTE WITH PLUMBING CONTRACTOR. M a w ! 4 4"0 DRYER EXHAUST DUCT UP IN WALL. CONTINUE ON SHEET M2.2a. PROVIDE AND INSTALL DRYER BOX 425 LINT ___ --- f:--_:_.�' FILTER. ------ — _----- i I-5a 12x18 L. (14x20)OSA DUCT UP AND CONTINUE ON SHEET ;l 1 3.._1.....`x: O M2.2a. PENETRATE RATED ASSEMBLY WITH CEILING 5 I ! i' CDIa oo I I :<i1 ;__.__ -- a 1_........_! i j RADIATION FIRE DAMPER. PROVIDE AND INSTALL MANUAL ` I I VOLUME DAMPER, MOTORIZED DAMPER AND CONNECT TO • ! VA F1, RETURN DUCT. ....__....__.............-.,...., PROVIDE AND INSTALL ECONOMIZER DAMPERS AND O ©i0 ! ICONTROLS. D _ E 4 1043 ©; ■ U ` — — — — — — — — — HR HR HR H4 — 30X8 L. , IV^ 701 (32x10) _ O 0A 2JH L F t1 , 010 2 O W of I 0 L ---I 1 nb mI 1 _ CD-1 175 ® _ 12x18 L. ,._................... I 1 1 0 1 1 1 1 9X9-2 14x20 ; CD jet m1 i i FURNACE OSA DUCT , _ ■; 1i I E i, ------ _ _ 1 �, ENGINEERING 108 ;3 2 TYPICAL ENLARGED .FURNACE ROOM DETAIL I Job Number: Contact: `t 14-0239 Jeff Stauffer Design By: Tele hone: k } S . E 3 l _ �� �� .. ' __._........._.....__ i m ; i 1 - M2.1 a 1/4 = 1 - 0 (503)36 - LS 3 2334 I Im =I II i ■ i THIS INOT BETA AND DUPLICATEDUSED ORS ___._._.. DIS ENT CLOSED TO OTHERS FOR PROCUREMENT E 1—..... OR OTHER PURPOSE, EXCEPT AS WITHOUT PERMISSION OF ,•'' ---, ' � OTHERWISE AUTHORIZED BY CONTRACT, V — — — — — — — — — L� — — IALL REPRODUCTIONS SHALL BEAR 23 THIS NOTICE. I X 5 I AI K #L 1009 MATCHLINE 1/M2.1b I I 1 IJP✓`✓ / " I N I 1111111 I 1 ImFEC7- - t / - - - - - - - - - - irL LL, (; U ■ I E t \l 1-2 - ?...._I._2._...._._._I 101 1 oz y -^� 7 1 1 1 1 14 119 X. 6 1-4 / - ■ 117 \ � I ; CD-1 150 _ ■ RR-1 925 0 9X9 TYP 2 I ---._._..............__._. ._ CD-13= ' =1 r \ REVISIONS: 12x24 �-__..::..----._......._------!� ! E ! ------r . �✓1�.-'� \ CD-1 175 EF-13 —E!I ------ — I ^+ � 4 / l!! ii I -.: s RR-1 925 V`r f ■ 9X9-2 TYP 2 1-5a \ 12x24 \ \ ' ------ 115 ' _ -- RRIDOR , f _ 1040 " 0 FOR 52 _._...; , ICiL D � y♦ ' 1� 5 9P T" � T ♦ i 105 - _. ---I --_.... ♦ , 0 CORRIDOR ' � 8a A._ i I I. I W \ <k ♦ J, ♦ \� 120 1 > I W �_.____.__._.__—.......... ,.,.- r 104 i.i�i ,I 811 0 L ; ok ; E :..._.._., � 1 1 - .. 8° t ;1 I , ;t \ © ♦yam ♦♦ \ o l/' 9Fy QJ�`c I d ♦I —T , ' '`1 - \ ♦� \ \ \ SYN N S C._....._. ti� ( 2X10 1 I I © © ♦ ♦ \'"j� \ EXPIRES: 06-30-2016 ® I © I ELEV #2 Al1� 16 ° 10"0--"' ,k^y ' - �. ♦y� �♦ \ pl© 1 I --- I 4 1 �o \ ® ♦� may♦ PROJECT TITLE: � ♦ ■ O i T � i O i ®� �' O i 1 o �0 �• © \ � ♦sem ✓'� " �f g��0 14X8 L. 1.0 a iIH aH FaH1 R >.H bR RH '\ 11 ■ 8"O (16X10) 16X8 L. E"G [14X8 L. � � � � �l � `\ - �-�� 2 3 8„0 CORRIDOR 10,10 (18X10) I 16x8 L. 48 16X1L 4 �� �� ,✓ U , 1042 f „ (18X10) MEt FSD ( ) ,k^ ` �� �` l'� � HR HR HR HR w HR HR Hi l..~' Fc)— __ 30X L. I (/�) �s ■ 01© I 4 1 6X8) 18X61 2 1 I L \ ' ' ' I-4a 1 ( ) ' (20X8) I ° 2 1I i M2.1a 1161 ■ --� E 10 i`t` t I ' i— jE / i 1 \ ,J �i [ I'co 1 I M M ' 'll i AUNDRY/ i -4a1...�a1 8 W❑ 1 1 *8 l l 1; -- j" 0 _ 112 ii ; LOUNGE FEI104 1VST1 4 li3 e ■ --.; 0 I 4 046 ; 4 I D TYP. 3 I m t.__._. . I i _,_.� f ® D ® Z ■ I f K D O q ` �� CD-1 175 ---- 1 9X9-2 TYP 4 � ------------------ 0 - -- a ------ --- - i C W ! F-12 o I W - _----_ o O --_- - - W B N o ■ EF-14 I F-11 SR-1 300 18X6 I CU-13 ■ SHEET TITLE: SR-1 325 A FIRST FLOOR I 6x6 I I cu-14 HVAC PLAN BUILDING "A" ■ "All KEY PLAN CU-11 FIRST FLOOR PLAN BUILDING A - HVAC DRAWN BY. SHEET: Q ' Q CU-12 M2.1a 1/8" - 1 - 011 FROXECT#: CA M2. 1 a DATE: -� 0. ■ X NOTES r-- M � .--i -� M M O 4"0 EXHAUST DUCT IN WALL. CONTINUE ON SHEET M2.2b. v) rn FIRECAULK AT PLATE PENETRATION ANN GWB 7:11 �O 00 PENETRATION. 0 kn s~ 2 2Y"COMBUSTION AIR AND VENT UP. CONTINUE ON SHEET o M2.2b. y " O %4N O 3 "CONDENSATE DRAIN TERMINATES AT HUB DRAIN. M si a w COORDINATE WITH PLUMBING CONTRACTOR. OTERMINATE EXHAUST DUCT ON EXTERIOR WALL WITH PRIMEX WC6. J SR-1 150 O %4" CONDENSATE UP TO MECHANICAL CLOSET ABOVE. CONTINUE ON SHEET M2.2b. 12x6 DOUBLE WALL FIREPLACE FLUE UP. FIRECAULK RATED ASSEMBLY AND CONTINUE ON SHEET M2.2b.PROVI ■y i _._.._______ _ 14 15 16 18 O DAMPER.GRILLES/DIFFUSERS WITH CEILING RADIATION FIRE O _._..-_:...... a H -----— W_._.....------------- _ O 20x10 L. (22x12)SUPPLY DUCT UP AND CONTINUES ON SHEET A-1 A-1 M2.2b. 131� F9 OROUTE DUCT IN JOIST SPACE. +O ■ _ i 2HR FW 2H FW I7{L13= ="' L914RIF E]WF:+ I--,-2klR 2HR 2HR FW 10 NOT USED I E I I I I 11 MOUNT DUCTWORK TIGHT TO WALL. 1111111 I T ® 0 1 1 1 1 1 1 1 FEC 171 :11 I I i STAIR FELEV #1 1 EWH-1 1 4 I I ! t G — — — — — —P I Al 11 It _ 1 ®� STORAGE 8"0 2 027 ; 24X1 _ , _ 1 ` H . 2 MATCHLINE 1/M2.1c I I I 1 i - - r - - - - 0 0 C DAL �- 8"0 W N 14x8 L. ROM I jet 6x10 (1 1 SR-1 250 i il'.'' —. SR-1 150 A f I -1 I � 18x6 TYP. 2 , 11 = = 12x6 TYP. 10 rl CD-1 75Pill 4777A ENGINEERING 9X9/2 TYP. 2 ------ ~ x I 12x12/4 TYP.4 7 14-0239 Jeff Stauffer Job Number: Contact: _ I Design By: Telephone: 6"0 0 min 1 J I I ........__._..._..._.__..' nl 10x8 L. I EF-3 x I (12X10) 2X8 L. ® JLS (503)363-2334 $ L �� /l (2 X1 O) THIS DRAMNG DATA AND DESIGNS THEREON EF-2 I O I S 10 10) 10 Ox8 L I CRG-1 1 OO SHALL NOT BE DUPLJCATED,USED OR �� A I DISCLOSED TO OTHERS FOR PROCUREMENT - f I 12x12 TYP. 2 OR OTHER PURPOSE, EXCEPT AS /------- 2x1 ! r f J OTHERWISE AUTHORIZED BY CONTRACT, SR-1 450 i, 'I 8�� y ,F% %�/� CRG-2 1200 7 WITHOUT PERMISSION OF j; li fl 24x6 TYP. - I 18x18 TYR 2 H a.........._ 1 I b A11 3 I I CD-1 100 F-2 i I m C- 8 - _ GRED 8 _ _ _ ALL REPRODUCTIONS SHALL BEAR 0 � .` R -2CO2 J. 5 2 O 9x9/3 TYP. 2 THIS NOTICE. WL-1 '- - -- �� -i I I 80 - f 1 1, k l i 6" EWH-2 ! uI I EF-5 ;: ,. :�...._., � � f- o H� i 24x8 I I JAN 4 8x 24x8 L. 30x10 %6x10) o 2 FF=9CO2 i �FFICEg��O CC OFFICE 1023 JAN RISER RM °x° 1022 1024 CV i ; J J CORR 2 n 00 +�J r 1015 --- _- -- --- - ? o c� O K . . u-- KITCH — — i' ? I I I I I I LOBBY ? 0 KITCHEN CORR 100 I 8"0 1 - -6"0 9 1019 1020 N 11 ;I, 1 DRY I il; I Ir TO - - - - - M 1 II R I N I ®® Z..,� 1021 ` o scorn t _ 0 I I li I I I I m WATER CD PR VATE SERV - ---- DI ING t �� 24•s/8• 1025 I 1 TOx8 L. SAIILOBBY1 �a - 12x10) t 12 G-21 125 1003 !1 I I 8,. � m II 12 ---, I C D1 5 9x9/2 L=____________..____....-__.._._.._.__.-__._.___._..__..._..........__._-_._..______..__.._..__._.___...__________-_____._..___._......_; I • I 1 C D-1 125 - --------------------------= OFFICE :.:: 4. FE 1012 1 9x9/3 TYP. 2 12x8 L. _ P P (14x10) - - - - 8„0 9x9% - REVISIONS: I I CD-1 150 9x9/2 CRG-1 150 RR-1 12x12 16x24 I I PARLOR 1 - - - - - P . R-1 125 SR-1 325 1004 STOR1003A 12x6 TYP.2 18x6 TYP. 2 i � I I CRG-2 250 SR-1 100 i I l I I i ii R i RTV-1 2 12x12 12x67=-� i '. - ” 1 1 5 1 1 CRG- 11 2 650 ` - ' 18x8 L. MAIL I ��� I I 1 16x16 i..._...._t__._..�.....__._.___...._.._., - (20x10) 1006 1 1 =----.�a � I I � PRO OFFssi wL—z 130x10 �; a 8"� ;.F ,. — — Q — — —/�� — — — — — — R . 1 �� 5 9P 9 12x18 L. `, f 1 I 1 FF=1 (14x20) ° r 2 O o f G GARDEN WORKSHOP/ C=) 15,2�� RR-1 500 I I -I 1007 O 1 IL DININ NN S'(P 12x18 - Y'-i 00 ROOM .?°„r SR-1 375 1010 �f ���j EXPIRES: 06-30-20=1 I \� ^� , PROJECT TITLE: 18X6 TYP. 2 R . 8 EF-1Ill- Ri6:11i FR VtR 111R FB MIN IIIR ❑ s – – – – — — — — — — — — — — — — — — – JJ EWH-3 STAIR #2 1009 I J 1111111 IMFEC f� 'moi � } MATCHLINE 1/M2.1a - 1-2 I-2 101 102 N 7 1 _. 4 17 19 o - CRG-2 1050 18x18 TYP. 3 7 O CD-2 350 12x12/4 TYP- 6 7 Q Z CD-1 150 B O Q 9x9/2 '� as � > z o O o KEY PLAN pq K'1 'N� FIRST FLOOR PLAN BUILDING "C" - HVAC SHEET TITLE: M2.1 b 1/8" = 1' — 011 FIRST FLOOR HVAC PLAN BUILDING "B" DRAWN sr: SHEET: Q PROJECT#: �• � Q E 1 xx 1b Q+ DATE: X n a, 110 00 I:1. fn 00 o CD m aj CD-1 200 12x12-2 TYP. 3 13 21 H-2 EF-28 ova RR-1 1500 16x3O F-19 ....... r-------- A- T — - — - — - CD E ii E-11 SE ai 0 SERVING Eil 0 1086 171 71 CD-2 300 F, 0 0 ZJ� LL-4 Z-1 Z-1 z 12x12 - .... ............ .......... CD-1 100 Cf) 811 ------ -------- 7 EDH-2 �H .1 m NH w a, bH b� bH 2 2 . 9 3 5 A. 6 A. 6 ENGINEERING 7-1 G CORRIDOR CU-19 Job Number: Contact: C 239 Jeff 0 14-0 Stauffer 81-0 r'r, SR-1 Design By: Telephone: 1-2x" jLS (503)363-2334 ---------------- A. 8 7E I A. 8 THIS DRAWNG DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR 0 DISCLOSED TO OTHERS FOR PROCUREMENT .......... ._._...,_.311 OR OTHER PURPOSE, EXCEPT AS OTHERWISE WITHOUTHPERMISSIONCOONTRACT,T, -7— S4OF1 - - - CD-1 L I 9X9-2 TYP.2 100 150 C ALL REPRODUCTIONS SHALL BEAR VEST F1 084T IS NOTICE] DS-3 (1,fxlo LOBBY A-6e CD-1 L MC MEDS MC 1083] F- CD 1 75 m R 11089] C) 11 149 ............ HART I F9X9-3 F1 FSD 1.0 FSD 0 6x6-2 m SR-1 225 12X TYP. 2 11 8"0 G I-T- S 1 20010X6 L. 10 '22 I -14x8 L. 6 TYP. 3 Ln m A IN. -! I ! i RR-1 Com 8 EF-20 16x1 0) 1000 F1 0 779 K 1080 !7 24 ........... 01 --T 0 CD-1 if28x8 -� (18 10) 9x9-2 12x6 EF-25 -------- EfL IcD 1 :1 r 9X9-2 TYP. 3 F1 478 1,=_ ............ (30��io).- 70 . ......... 47= EDH-1 Cn ()0 ......... ............ LEC /No Y F-17 ............... T- au I ------------- N r-i LIVING 106� r---.1 1, i, -- I i I SR 125 6' ROOM ZA31 1 23 0 Z- 1bw -1b Z-1b CD-1 75 '0 K: 6"0 -3 r7i ........—------- 8110 9X9 F�.. .......... Cf) 16X8 L ' ..........I I I I! 51.0 18- Fa- 16x8 L wr % 8x Wo- r2 10), H E -29 A 1(18xlo) 6L SR-1 K8) EC 12x6 2 146 F 14x14 L. (14 (2q?�l 0) f Ii 24x8 L A-2E i1 � I I 31W 150 CP,F1 STAFF . ....... RR-1�' j- E=41 FSD �1 6x16) 12- .......... I U, 1070 11 D \L�Ifl ELEC D 'iR FQ 11IR �C) (1 4x1 0) 0 (28 10 1 75 ❑ LAUND At.A I 16x24 I ��DD H P 0, 11 F10976 D �=A 12x8 L. =E� WNH-16 -- - - - 14x14 L.-Al HI, 8J �JH I. 8J dHI 11"J IIHI 11-1 111-11 #7 (T6RTM- STAIR 6 - — - — - — C. 4 I FSD 6-0 FEC 10x8 L M[ RI FSD 8110 6-0 REVISIONS: 1098 1 8" 1 28x8 L. Wo 24x8 L. 8"0 (11 2x 1 Al F rWAPT(Z L CORRIDOR I /-(30x10) R (26x10) ---- I-I * Fill 6-0 ----w ---w 34x -L.- 1077 FSD IUOj 6110 8"0 U2fl (36 w IR w w w HP C. 6 w HR FSD FSD 0 0 0 0) lcnFSD 1HR 1HR 1HR F 0A �JH I, I; 9=1 �ji-u n 1 \I I� STOR. Lo 4"0 1 -N 0 41-0 :WH-7 [1-0973 y 1,--4" ............. =7,v -7 STOR RR-1 Cn Eix v 0 --L- u tT1 1 2000 1-1771 18x30 F-T- F-1 E) EN F FSDZ-A2 A-2 Ej I-r—FSD 1 F11 I I .......... i I A-3b--. 8--12 -------- \-28x12 L. SOILED 6x16 L (30xl 4) 14! 1067 14x8 L. (I 8x1 ts) 6"0 A A (11 6xl ........... FSD 4�m� Z- 1bw P 110 1 b IZ-1b Z�A4b 15 9 Oil I I A ............ -J F 77 A E Lj di] cn L] --------]z 1,71 j S1 FF ........... A 15 1061 m I 'N N SSP D D 110 v i --——--------- i, 1 125 i 6 G FEXPIRES: 06-30-201=6 -------------- —�D-1 150 oo 9x9-2 1 TYP.2 EF-2 -17 9x9-2 TYP 2 CD-11 150 F .............. r r-A-4cr-i I VICE) L-j 0- 9x9-3 01 I CD-1 I o F1 0 670 PTHP-11 DS-2b EF-26 F-18 !F=====Z��A4,cl 0 ORRIDOR F-15 A A A A 9x9-2 1 n--- I EF-19 A A D-1 100 A A L............ EF-21 1 CU-16 9x9-4 E-1 5 r 200 U 17 12XP I ) 1 16 18 ........ CU-20 ......................... ------------ CU-18 ............... �70 VK A 1 ----------A=�lt CU-21 CU-22 131 A-6e Z�IA60 ........... L153J L;U-zj 0 2HR FIN 2 :W R Fli HR V 2HR FW CU-23 EE .. ............. .. . F FIC STAIRe- ELEV #1 3G rA STORAGE �111. P , �.Ijj '0 027- - - - -------- H . 2 m m LN 0 �11 ' 0 0 ■ 0 m 0 coil AL DININq MATCHLINE 1/M2.1b ;:3 > ROOM WOME 0 m N U 1031 F1026] (E) <11 77 C ;:3 _ `---_...__._._.__I CA CAFE B SHEET TITLE: FIRST FLOOR FIRST FLOOR PLAN BUILDING "C" HVAC HVAC PLAN BUILDING 11cif ��-JIC 1/8 if 1 1 - 011 A DRAWN BY: SHEET: PROJECT 4: 13xx Jt T T 18 Iff KEY PLAN M2. 1c DATE: 0.< X M *—y M M � � O M 000 i-. M �. O M m OHO NN _ NOTES w M un Clr O4"0 EXHAUST DUCTS UP AND CONTINUE ON SHEET M2.3a. I CJ Q O MY"COMBUSTION AIR AND VENT UP IN WALL.CONTINUE ON ■ F- SHEET M2.3a. -- n ROUTE/"CONDENSATE DRAIN TO HUB DRAIN COORDINATE WITH PLUMBING CONTRACTOR. ! -- Y. F...._... I 4"0 DRYER EXHAUST DUCT UP IN WALL CONTINUE ON n f' ' i 1; , L._.__..__._..___........___._1 2.3a. PROVIDE AND INSTALL DRYER BOX 425 LINT Ntu ) I sl ! f SHEET M FILTER. H ......._..... I V, , 12x18 L.(14x20)OSA DUCT UP/DOWN AND CONTINUE ON ---- I 1-5a ! (( L ! CEILING ; o _.__ RADIATION DAMPERS AT MEMBRANE PENETRATIONS _.... ._. ,�I I �=rf � 207 ' , O PROVIDE AND INSTALL ECONOMIZER DAMPERS AND -- ©© I I CD-1 175 CONTROLS. o -- - I 0 O7 24x18 L. 26x20 OSA DUCT UP AND CONTINUE ON SHEET ■ "' ---I M2.3a. PENETRATE RATED ASSEMBLY WITH CEILING Mf? ..............._._._, - - - I t-� ® RADIATION FIRE DAMPER. 12x18 L.(14x20)OSA DUCT DOWN -- T AND CONTINUE ON SHEET M2.1a. CODSTOR __..._._...._.____._— ©I© 34x8 L. O8 4"0 EXHAUST DUCTS UP/DOWN AND CONTINUE ON SHEETS Lo (36x10) M2.3a AND M2.1 a. _-- FSD j - FSD — O IN WALL r 1 O 9 2 "COMBUSTION AIR AND VENT UP/DOWN CONTINUE ON SHEETS M2.3a AND M2.1a. 8"0 --_-__- ! fl ■ ® 10 4"0 DRYER EXHAUST DUCT UP/DOWN IN WALL. CONTINUE .E._.._._.._. U - - - - - - - - - - - ON SHEETS M2.3a AND M2.1 a. —i HR HR HR H0. i I 24x18 L. I ©I© FURNACE J w ---I 1� do =1 t - - .I- �1 jet ©I© 1ml OSA DUCT �. .:_ ENGINEERING !; _ 'o DETAIL Number:Job Numb Contact ----- —i, ! I' Jeff Stauffer __., 4-0 39 II 11 '!e 'i —i NO 1 (� I' I-3 !, I` :`: n n Design By: Telephone: -.-- -- 1/4 1 0 JLS (503)363-2334 ! THIS DRAWING DATA AND DESIGNS THEREON 208 ; a SHALL NOT BE DUPLICATED, USED OR Ll DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERIMSE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF V — — — — — — ALL REPRODUCTIONS SHALL BEAR 23 THIS NOTICE. X __6] _6 M I I ' / \ MATCHLINE 1/M2.2b ■ ■ ■ ■ ■ ■ ■l-2 ■ ■ ■ IM ■ ■ ■ ■ i ■ ■ ■ ■ ■ ■ ■ ■ ■ co I I it =1 / � ■ - - � - 1H - - - - - - - - FB FEC — - - - - - - - - \ 0 MH ■ I E !;i 'L i E IV ' _._._.....__.... 1-2 1-2 201 202 �" © T / 1 0 ... 219 --- c) \ ° 217 ! i 1 ■ CD-1 9X9-2 TYP 2 CD 1 100 9X9-3 4 � x CD-1 175 �- 9X9-2 TYP 2 —!;_fr.T RR-1 1500 _ 1-5a -' 12x36 ■ ----- 8"QJ ___-- 215 REVISIONS: CORRIDOF 2040 ---- - �p 8 FEC I JD =-- �r y / III (\b \ 1-5 � ! ! - !! 8"� 205 3 ©b !1'L ! CORRIDOR ��' ... a ;�_._. n �/ --'---'-'----_=- - -'-'---____...._. � `ham' ' � , STOR ! I 204 ! �! � � O 2050 �� J� � 320 =u. i !i I i_.... -7a! 8"� k �� ` 2041 I 213 © I l ELEV #2 10110_/ i --- I I 9 © 10,10 I d II © � ` --+� I--- I ® Q ---- y I -- i 8.. -' _ t — — 14— 14x6 L. "H F-13 >„� 8„ 21 1 : t-L CORRIDOR 8„ 10"PJ 8' /14X8 L. 6„O (16x8) 16x8 L 16X10 �o j 4X8 L ; ti / / �; " ■ -1"0 ( ) ( 8x10) FSD ( ) 4 '� 2 3 EXPIRES: 06-30-201=6 2042 a HR HR HH PROJECT TITLE: ■ O � +-+-- LAUND ( 8x10) x Q I ; 9 (24x10) 9 , I 34X8 L. ©© I 2047 I I (36X10) � � �� I-4a � 0 216 F1o � � 10 cn Lk j ! _ - I � ■ I I . II ;'—; 1-4ai j 8 I ® I I _ ~ 206?I '! � I 204 � a I _ 212 i_.._; ;� ��1 214 •t ! ! I ! I 10 11 - '' f—' h 4 I !i I { 01t a 4 _ fE 10 _-.._ 10 I.LR; I — --._--- TYP. 3 or! ■ I ! _!! m, -.-.; - - - - - - - - - ! ! �! t_ 21 — _ — _ - - - D 1 75 _ 9X9 2 TYP 4 i L-- I F 13 6 - 1� W W :.__.__i...._._._._._._....__._...._......3____, R I I I � Q Z SR-1 125 i, ,7 p Q ■ 12X6 W U I EF-16 I I A Oa a ■ KEY PLAN Z N O O SHEET TITLE: SECOND FLOOR ■ SECOND FLOOR PLAN BUILDING "A" - HVAC HVACPLAN I M2.2a 1/8 = 1' - 0" BUILDING "A" DRAWN BY: SHEET: A I PROJECT 4: 13xxM2.2 a � AT < Q X + J KVU 1 C 74 tJVIVUGIVJH I G UI[HIIN 1 V HUD UKHIIV, IiVVRU1IV/i I C WITH PLUMBING CONTRACTOR. M O TERMINATE EXHAUST DUCT ON EXTERIOR WALL WITH PRIMEX WC6. MOUNT FACE AT 32"A.F.F. �W M OTERMINATE EXHAUST DUCT ON EXTERIOR WALL WITH PRIMEX WC6. o cri O7 DOUBLE WALL FIREPLACE FLUE IN SOFFET. CONNECT TO O o APPLIANCE. FLUE CONTINUES UP ON SHEET M2.3b. FIRECAULK PENETRATIONS AT RATED ASSEMBLY. M �naw ODOUBLE WALL FIREPLACE FLUE UP/DOWN AND CONTINUE ON SHEETS M2.3b AND M2.1 b. FIRECAULK ALL RATED PENETRATIONS. OTERMINATE EXHAUST DUCT AT ROOF WITH BROAN 634 ROOF CAP. 10 ECONOMIZER RELIEF INTO ATTIC SPACE. , , A 11 2 y" COMBUSTION AIR AND VENT.TERMINATE ON ROOF WITH y -2) ! FURNACE MANUFACTURER'S CONCENTRIC ROOF VENT KIT. _�_ _ _: 1 ---- 14 15 16 18 7 1 !.._................_...._...._..1 12 ROUTE IN JOIST SPACE. A-1 7 A-1 13 2 Y2 COMBUSTION AIR AND VENT IN WALL. CONTINUE _ UP/DOWN ON SHEETS M2.3b AND M2.1 b .._........................._...; 2 31= t- - _ � .._....2.3{}.._ I I I I O - - 7 I 14 16X16 L 18X18 OSA DUCT PENETRATES RATED CEILING 1� ■� MH 1 ( ) 2. y,l -- 21 + - 2 RFW - -- - _2. I k .:_;__ :" 2F�iN 2FERIRU6W E _ - 2H�lrw H _ - WITH CEILING RADIATION FIRE DAMPER. PROVIDE AND INSTALL MOTORIZED DAMPER AND MANUAL VOLUME I 1 �= MH i I I DAMPER. -1 1400D Q 22x24 � I r O W AV/STOR 009 15 18X18 L(20X20)SUPPLY AND RETURN DUCTS UP. PENETRATE �COFEC 20pgg 1 i 2009A I RATED ASSEMBLY WITH FIRE/SMOKE DAMPERS AND Z _........ :.... I -- CONTINUE ON SHEET M2.3b. F-5 �E� #1 I STAIR 3 :.__..:._. - O MH - 16 20X10 L(22X12)SUPPLY DUCT CONTINUES DOWN ON SHEET WL-6 - - - I 1 - - - — —'1— � M2.1 b. 7�1 I - J i 17 PROVIDE FIRE DAMPER ON SUPPLY REGISTER. MATCHLINE 1/M2.2c I 6"0 12 _-F. -5 `~-- i i"- . - - I 18 PROVIDE AND INSTALL ECONOMIZER DAMPER AND � ■ � ■ ■ ■ ■ ■ �i ■ j - � ■ ■ � � E� �� ® ■ �I■ � ■ � ■ ■ ■ � CONTROLS. 12x8 L. EF-10 (14x10 01 }`' I � I 19 2�" COMBUSTION AIR AND VENT CONTINUES DOWN IN WALLt 12„0 12"O ON SHEET M2.1b. — I 2016 30x8 L. J 12"0 I ' EF-9 5 J 32x10 20x8 L. 20x8 L. \ L / 20 18X18 OSA DUCT DOWN AND CONTINUES ON ENLARGED I I ( ) ' (22x10) (22x10) '''' I I KITCHEN PLAN SHEET M3.6. _ a°0 f-r ENGINEERING f 7-t ! — �" 1 Job Number: Contact: H ..4r= k�v t� .,. �. _._._... �'�, r 14-0239 Jeff Stauffer I f f \� -CO2 1 I F-6 18 Design By: Telephone: JLS (503)363-2334 is F-8 RR-1 1300 THIS DRAWING DATA AND DESIGNS THEREON 1 SHALL NOT BE DUPLICATED, USED OR RR-1 1200 I I _ -_-- 3QX I 18x24 DISCLOSED TO OTHERS FOR PROCUREMENT 12x30 �� i ``E I OR OTHER PURPOSE, EXCEPT AS 32x10 OTHERWISE AUTHORIZED BY CONTRACT, IITHOUT PERMISSION OF SR-1 250 I t Il �� SR-1 375 1 E k I !i I 8"0 I I 110 12"0 I 18x6 TYP.4 12x6 TYP.2 I FITNESS 16"0 SR-1 350 2015 1 ::1 — - — — = I v l e 18"0 — — — 5 ALL REPRODUCTIONS SHALL BEAR R THIS NOTICE. 18x6 TYP. 3 I I 24x8 L. 16 10 16 0 �' TG-1 I l I I FS (26x10)i F-7 18 24x12 PYP. I j I M 18x16 L. I 1 I I I X 15 (20x18) - M K - - - - - - - - - - 16x16 .16�� - _ SR-1 200 I I I - - - - 14x8 L. 34x8 L. 12 (16x10) ino:=-7_1 20"QJ I I (36x10) 18x22 L. I I I HOSPITALITY ( 11 (20x24) CL _ _ _ _ — I I I 2007 20x8 L.-/ 20 J J I I (22x10) I 1 ELEC-LV I MECH DS-16 EF-8 — — — � --J I — — 1 008 8"0 I SR-1 275 1 SR-1 200 I I I I I ( I 11 12x6 TYP. 2 12x6 TYP.2 I I I I SR-1 200 RR-1 1500 I 7 1 I I 12x6 TYP. 2 CM 18x30 I - - - - - - - - - - - I - - - - - - - - - - - - - - M 30x8 L. T RR-1 1500 SR-1 250 I (32x10) I 18x30 i 12x6 TYP. 6 I I I COR ( I 32x8 L. EF-7 _ _ _ 1 2001 (34x10) I I I I I 10'0 1 I RR-1 1200 18 8L 4X12L WL-7 CNL J 16 L I (2x10) I 18X18L (26X14) I I I II CD-1 75 18X24L 6X6-2 (20X20) OR (20X26) M CO2 M _ I I 6-0 ® " I 24'0 I I I REVISIONS: 4 STOR 2003 1 9 16"0 TY .3 MEN < 8"0 20 1 6"0 , 8.0 �C./ x � j I 18"0 I I I 8 24"0 I M F-4 I _T71) F 8 :X1:8) I --r M I ���p PROFFS - —12x8 L. _ ACT/ R (14x10) I CRAFTS i _ _ _ _ _ _ I _ _ _ _ oo 2002 0 - - r E -1 R . 1 �� 5 9P 9 IF — - - - - i G 8"0 CD-1 150 20 - - - -= 1 9x9-2 P. 5 q X1'15 WL-5 I I �7 FY (P 300 tYN N S I I I F-4 ACT ACT t 18X P.6 EXPIRES: 06-30-2016 DIR KIT I I I I I SR-1 500 1 I I 20040 2004 Q PROJECT TITLE: 24x6 TYP.3 C) 4 - - - - — — —_ - - - - - - - R . 8 — — — S I 1 ' STAIR #2 I WL-4 2006 I 12"0 TYP.6 H-1 � m' I T EF-6 I I 1HR F 1HR FB FEC MH I I I 10"0 TYP.6 - - - - - - - - - - - - - - - - - - T I's———9 ;— ------- g M PH iiu ..-........... MATCHLINE 1/M2.2a I I U 201 202 N 7 (Di 1 1 1 14 17 19 _. ------------ I ►� � O WLM, � Q o � B � 0 W a as A 4- KEY KEY PLAN pa SHEET TITLE: SECOND OOR SECOND FLOOR PLAN BUILDING "B" - HVAC HVAC LAN BUILDING "B" M2.2b 1/8" = 1' - 0" DRAWN BY: SHEET: Gl w Q PROJECT#: 13 M2.2b Q DATE: __l a a x M O O C) rq r y C) ' J �4 'M 13 21 1 . 1 . 22 O O 1 , I I RV-1 1 I I I COO A - - - - - - - - - ------ - - - - - - - - - - - - - - ---1 - 10"0 - -I - - - - A I 14"0 I I O I 10"0 I 12"0 18x18 1 10"0 I I I --- I , I 16"0 I I�--: � het 2 2. 9 3 5 A. 6 - - 1-1- N _ 18x18 L.-4L-_ _ I _� - I _ _ _ A. 6 �,�.--• �I - - - - - - - - - - —�— - - - - - - - - - - - - - -(20x20) 14110 - I 10"0 - - I I ENGINEERING I 8"0 1 ,010"0 10"0 Job Number: Contact: 14-0239 Jeff Stauffer - - - - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - - - - - -I - I y Design B : Telephone: I I I I I JLS (503)363-2334 I 1 I TMIS DRAINING SHALL NOT BET DUPLICATED,A AND DESIGNS SED OR ON I I DISCLOOSED TO OTHERS R OTHER PURPOSE, EXCEPT AS TENT 7-1 �7 OTHERN95E AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF i t t I ( I I I ALL REPRODUCTIONS SHALL BEAR F-- THIS� r� NO710E. I , i I : I I I 249 1 1 , 244 -----; 5�_.- � I— (r J L i_ � �] ! i o , ............. T �, EF 30 T O EF 32 V L/ - I SR-1 225 EF-31 12x6 I ! l .................._.__.._-__f�._.__� ® r T;_._.._..+. E , i __ Elt:l`=` CD-1 175 _' _I1 .; .._.._. i Cr; ,;I , o E 's E. i € 11i I I ! iii i it i ! E i i ! .._ r ® I 9x9-2 TYP.3 __ Ii _ IIl �._! T i � I I I I ---1 -----�;�---• i_.i_._____,! ` '-�- - - - - - - - 1 - - - - � - - - - 7_1111 i I ;� i ;—•, ! �I I ii I , ! 1. I rrE EE AUN iii i t i E : _"'-'----• n i i r-- , i 2078 i 1 1 I I €E i € - - -- is � i.� i EIi E i L._.�.._._.__...__�_1' !_._.- - ti.__..._._F• „�f i 1 i .._._.._...._....._... t i t.__..0 i E.1 ' E i :: i i € I E I ,i � 1 ! i r_....._..----• i i �•.','i. ! i I" A-3cr A=��t 4 Wnf_ lil I E I — cn I _ Y _I _ I I _ 239 _____-_._ 12 � O ;--------I.---,,:;____.__;. 11 i _ - s ;, 234 i i 235 � _ � 11 1 ;, i � ACO DOR � ------- �Y i �,......_ar.. x i_...—.a._.—a_i i-— -- - ----- _`.1 s---- ( _..L_�.__ 1 ! _ i ' __..... `--" ` I----`' —---._� ._.._ I — 1 �' _ �� 0 . 1 250 N __... i I rj Ii -�1 - J I� A _...... I I 2 6 ;243 I It 1 �"9 L ; I ---_ W 37 I I I I PHONE/ I _�._..... _ ELEC STOR DATA � `� Q i' 2�-. I � 1 � PHONE/ � •..i �� + I DATA 1HR FB - 2096 94 2092 ` ' o , 2071 I 73 L x I 1 --+ e , o --- FS D --- I e +-- C a 1 2 2075 eJ �Hi GJ ?JH eH e J NHt -- -- S IR 7 :- - - - - - - 8"0- - - - - - - - - - - - - - - - - C. 4 oil I TAIR S #6 " s II II I I 8"0 8"0 8"0 8"0 _ I 6"0 I 8"0 2077 REVISIONS: 16x8 L. CORRIDOR I I 14x8 L. 16x8 L. CORRIDOR 0 _. � 8"0 FSD (26x10) (18x10) 2091 10"0 f(16x10) (18x10) 2069 ~ 6"0 ii i I ! I — I p p f'`, - HR lii 5R HR HR 28X8 L. I - € i e 1 --+ - ---- ---- ---- ---- - +-- —— — — 1 — — — — — x EC STOR O o , O °° 1 4"0 TOR 8� NHL --- ---- a I r 14x14 L. VIV '1F1 (16x16) 2095 , I I I \ry + 072 if _..._ _ ® STOR —' I I i- �_ 70 ;� EF 33 2093 I _ _-- -- I 20 I i i rr T — RR-1 900 8110 rz�::.._-__....._ i ,, 12x24 I , ,>1; I , I—T-._._r_ �_„� I - -; l ; I I A-2 I , 24x8 L. I _.......;I-___ __ , ---.._.: _____......._ �_.� � , � � � ® _ 'li - a_.i._._.__._._.AI f._.....`1 L i i , I 251 (26x10) i� �. I .... t 242 i !: V:x i I ; ! I I I_. , F-20 1 ICI! 1 i ! '� t 11 1 i ICE, i i 'i x _. �i 4T , Y, D P R AFF L131 t i i I _ __..____- ` ................... ! ...i T--'' '_._'1.. .......-'ee �` i ,.......... 1?€; — --'I ';•`i GENE �O , i —A; 1 b �. CD-1 125 9x9-2 TYP.2 _-- ! I+ i € t i i _ I t I V !Ni1 _- I X38 ,i ---- ! ' I , 1 - cr - Cr I i! I i ! —__ I cl) i G I I is i i t i E I I ,__ ii E i— l_.0 i � 1 ii -- it Ing I I ' 233 I ,I I I I 2�2 I I � I :�� I ;I i - ! i! s !' I e r E :---...._..._-��_._ --- I '�., - __...._. :::-:.::::.._.: ! 9 5 2 J�� , 1 i` 1, ES: N 06-30-2016 1 `Y }_ 1 �— _ EXPIRES: I _i.T i CD 1 50 Ei Cr ��----... , I_._____,; I I t I! r...._ ; -1 ® �_ } —;'I '__�.--�;_. OCORRIDOR _,-__J_.i.--� ,tJ I O , _ �% I CORRIDO i—ti 2060 8"O I I I G �..- _._._.._._...-. 1 150 — __ 1 r 1 i I I 9x9 2 tr; I E i ii !. I I' i r- 1 � _� 1 - --- 14 15 16 18 - rr —_J — gill r- ) A 1 iE E i I - i ` r:.� __._.1 LI� J€ 17 { �� •—� I � ,_,T �� - m_ ILEI 2531 D a r' -- - �FW - -- ! _; , I' , it it j i li E ! 2H�}Y'IFW H W I . . .:...._.. 4ki�glF 2 2HtRl 2H1RIRIAW I i ! i! _._._--,__._,... I r = MH T 1------ _. 1� I T O I AV/STOR STOR N Q °°FEC I 2009B , E 2009A I I - - - - I - - - - + I I I I i I I _ tt I I I I AIR Q ST2018#3 - M H G I I I I � — — L ILJ r-r EC --- - D MECH MECH 1 T- L J O 2017 ! I Q S >� 21 1 . 1 . 2 2 f l - _:_:i_._ l i 01 2009 , 4_4 > Z � MATCHLINE 1/M2.2b I I ! ��`� 2 2. 7 2. 9 3 5 I i t I �3 SALON z I I 2016 ,i� , � I� a ' t o B SHEET TITLE: SECOND FLOOR SECOND FLOOR PLAN BUILDING "C" - HVAC HVACPLAN BUILDING "C" M2.2c 1/8" = 11 - 011 A DRnwr113Y: SHEET: Gl w PROJECT 4:_ w KEY PLAN 13xx M2.2C DATE: H I¢a a X i ' CV NOTES � M I � kn M '-' M ■ � W w � c � I O 4"0 EXHAUST DUCTS UP AND CONTINUE ON SHEET M2.2a. M 0000 z kr) ■ U a� M 2Y2"COMBUSTION AIR AND VENT UP IN WALL. CONTINUE ON a Mo �= SHEET M2.2a. O ROUTE%"CONDENSATE DRAIN TO HUB DRAIN. COORDINATE cq � WITH PLUMBING CONTRACTOR. M con P. �Z. I 4O 4"0 DRYER EXHAUST DUCT UP IN WALL. CONTINUE ON SHEET M2.2a. PROVIDE AND INSTALL DRYER BOX 425 LINT FILTER. ----- O 12x18 L. (14x20)OSA DUCT UP/DN AND CONTINUE ON SHEET M2.2a AND M2.4a. PENETRATE RATED ASSEMBLY WITH °•° I i CEILING RADIATION FIRE DAMPER. PROVIDE AND INSTALL I I I MANUAL VOLUME DAMPER, MOTORIZED DAMPER AND ova 0 lID i I CONNECT TO RETURN DUCT. 010 CD-1 175 y QIw 9X9-2 i 4 i P _ O AND INSTALL ECONIMIZER DAMPERS AND CONTROL. O 7 24X18L 26X20 OSA DUCT UP AND CONTINUE ON SHEET M2.4a. PENETRATE RATED CEILING WITH CEILING REDIATION al© FIRE DAMPER. Q 4"0 EXHAUST DUCTS UP/DN IN WALL. CONTINUE ON SHEETS it U 4 - L M2.4a AND M2.2a. > qu I O 2Y2"COMBUSTION AIR AND VENT UP/DN IN WALL. CONTINUE 0 8" 0 ■ ON SHEETS M2.4a AND M2.2a. 4"0 DRYER EXHAUST DUCT UP/DN IN WALL/CONTINUE ON U i _ FSD SHEETS M2.4a AND M2.2a. O --+ ■ 34x8 L. 9A NH[ � 1 2 ;�---,--- _ (36x10) 11 24X18L (26X20)OSA DUCT UP/DN AND CONTINUE ON SHEETS m' 1 ©i© ® M2.4a AND M2.2a. PENETRATE RATED CEILING WITH CEILING --- rl of i © ® RADIATION FIRE DAMPER. m I ------ 24x18 L. I ml -- I I i I - (26x20) (DIE) �W =� ��--- FURNACE J ©Q 'j •-� OSA DUCT T �= Mi J t I ------ I Na m i I ENGINEERING 2 TYPICAL ENLARGED FURNACE ROOM DETAIL Job Number: Contact: 14-0239 Jeff Stauffer Design By: Telephone: L NILS (503)363-2334 'm =' ■ �3a1/4" — 1' - O" THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS V - - - - - - - - - - OTHERNASE AUTCONTRACT, ■ WITHOUT PERMISSION PERMISSIOIO N OF 1 I ALL REPRODUCTIONS SHALL BEAR ■ 23 THIS NOTICE. J i \ x X ' s 3006 1 WO I I \ MATCHLINE 1/M2.2b I I I ° I 4 M I CV ' � I I NN cli 1HR F LFB IHR FB IHR FB � _ _ _ _ _ _ _ _ _ _ � ■ I - - - - - - - - - - _ - - —8S 9 8S 9S 8S 9S I \ -i U, I ---- --- I / I U F ■ \ Q 2 I-2 I-2 \ ■ 301 302 � X. 4 7 1 I 1 1 D14 I 1 I © 0 - — CD 1369 X. 6 --- --- �\ I-4 \ � ■ \ / 317 \\ ,- � CD-1 150 ■ EF-17 O9X9-2 TYP 2 / \ ® ® CD-1 1 100 \ \ o \\ \ REVISIONS: I ------ 9X9-3 .•° \ \ - CD-1 175 O \ ■ 9X9-2 TYP 2 RR-1 1500 \ \ 10 \ I-5a \ ' ------ 8"0 ---- 12x36 315 \\ 4 \ \ 10 ■ _ _ _ CORRIDO \\\\ 4 ©\© ® 3040 ----- \ STOR \ ® 1 Y ■ 1 I 4 ,�- ♦ \ Ep PROFESS ■ 305 I-lel ©IO 8 _ \\ ♦� ��♦ � 303 °b ` W I-8a 1 W \\ COR0500R �k / ♦sem s °�♦ \\/ 320 I-6e2 15W9P G C I STOR I _ 304 I-7a 0 ♦� r, ♦ �p \ ■ .� 3041 i 313 � ,� d© ♦ ops � ♦ `�© T �'3 �� • i o� .. i - ��� I 'W i \\y ,� � © \o ♦y� � `r ♦ \\ \ °.° \ o \ 9Ey X15, - I � I I I I � ° •I �'� 01 � i i 10 \ ' � \ '\ \ ® 10110—/ .• \' ,m ♦ \ � \ N N I 1 I i I ELEV 2 ! 10"0 1 � I 4 6 0 �` 0 \\ \ `y pN ` \ EXPIRES: 06-30-2016 ©I© II --- 30 \ ® ♦ �♦ PROJECT TITLE: y E C) --+J --- I ® 0 ---- 0 I -- c ) A � - - ■ " n n I Iz 2� 1 O u 14x6 L. a aH aiH aH 8u tI \L\ \ 318 `� c) CORRIDOR 8 0 10,10 8"0 14x8 L. 6 0 (16x8) 14X8 L. 23 10 \ t� (16x10) I I FSD (16X10) o 3042 HR HR HR HR HR 16x3 L. ■ i i 0 O= 61- FSD LAUND (18x1 0) L. ©I© 4 I 1 20478 1 4 i 9 �` (36X10) W \ \ \\ I-4a I I I 22x8 L. ■ - ® i I 10 5 I© 0 ❑W ❑W 717 ©i (24x10) M2.3a 7 O I I I o ' I U offI 1 (D10 10 I I� IM M , � + ■ T— I-4a 1-8 I 1 ® 1 1-8 I I-7b 306 304 10 M I d ° _ 312 314 I I I 0 0 0 I 4 4 I 10 I C) I 10 + - - - - - - - - - - 1311 I TYP. 3 - - - - - - - - - CD-1 175 9X9-2 TYP 4 U ° -- -- C W d 8 a F-14 6 x a� W ------ ------ W B O Ll I SHEET TITLE: SR-1 6 125 EF-18 A THIRD FLOOR HVAC PLAN ('1 'N� THIRD FLOOR PLAN BUILDING "A" - H VACBUILDING "A" KEY PLAN DRAWN BY: SHEET: Q M2.3a 1/8" = 1' - 0" •■ PROJECT#: 1 . 1 M2.3 a 13xx DATE: l 0. x 1 NOTESM M 1O 4"0 EXHAUST DUCT UP IN WALL. CONTINUE ON SHEET M2.4b. O M 000 O2Y" COMBUSTION AIR AND VENT UP IN WALL. CONTINUE ON bA M, SHEET M2.4b. o O o 0 OROUTE%"CONDENSATE DRAIN TO HUB DRAIN. COORDINATE WITH PLUMBING CONTRACTOR. N o zi a w ODOUBLE WALL FIREPLACE FLUE UP/DOWN AND CONTINUE ON SHEETS M2.4b AND M2.2b. O4" DRYER EXHAUST DUCT UP IN WALL. CONTINUE ON SHEET J M2.4b. CONTINUE ON UNIT PLANS. O4"0 EXHAUST DUCTS UP/DOWN IN WALL. CONTINUE ON �w J - -- SHEETS M2.4b AND M2.2b. _ ®M O 2Y" COMBUSTION AIR AND VENT UP/DOWN IN WALL. y CONTINUE ON SHEETS M2.4b AND M2.2b. 7 1 1 2D 14 15 16 18 O16x16 L. (18x18)OSA DUCT UP AND CONTINUE ON SHEET M2.4b. PENETRATE CEILING WITH CEILING RADIATION FIRE A-1 A-1 DAMPER. 331 330 I I O16x22 L. (18x24) OSA DUCT CONTINUES UP. PENETRATE r , I I i RATED ASSEMBLY WITH FIRE/SMOKE DAMPER. 18x18 L. w �a 2HW iHMRFW 2HElifnFw 2H —+ = 2(RFW 2r> IRww 21Ruaw 211 21IRww (20x20)RETURN DUCT DOWN AND CONTINUES ON SHEET _ M2.2b. I I mIn _ ® ' Q I I 10 PROVIDE AND INSTALL ECONOMIZER DAMPERS AND _ c� l CONTROLS. Z z STAIR #3 I � 3007 I - - O I _ I 1HR F B 1HR FB 1HR FB 1HR FB 7 1 8 1 H — — — — — — — — — — — ------ — — ® El MATCHLINE 1/M2.3c I I 6 4 6 ! 1 - 1 H . 2 � ■ � ■ ■ ■ ■ mom ■ ■ ■ ■ ■ ■ 0 1miImm= ■ ■ ■ ■ ■ ■ ■ Jet D V\\ F—A -1- 00 -Fq::::� I JL M0 I I-3c2 i I I I -- _ _ _ _ _ Q ENGINEERING 5 -- I H 8 H . Job Number: Contact: 14-0239 Jeff Stauffer _ _ _ _ esign By: Telephone: (503)363-2334 6 TIHIS DRAWING SHALL NOT BEDUPLICATED, USED OR 12x 2 DATA 1—HC 8"O 1-3c1 24 DISCLOSED TO OTHERS FOR PROCUREMENT 326 °� 1 I I OR OTHER PURPOSE, EXCEPT AS ( 327 OTHERNASE AUTHORIZED BY CONTRACT, o W0 I WITHOUT PERMISSION OF F-10 10 ( i 20X8 L. 8 I© 1 (22x10) I EC ALL REPRODUCTIONS SHALL BEAR J. 5 2 O THIS NOTICE. I I I I -- 1 4 6 1L 0 9 n � ® 0 � , II 1 K — — • •o M — — --- I L — — — UK � - — I 7 STOR I I 1 1 1 2 3004 1 - - - - - - - 00 F � - - 5 J LJ i i ___ I ° I I I I ® I I I I I I I I 8"' 1-6c1 CM 324 J UM IDW + 1-6c2 CORR I - + 3001 I p p _ 1 --I-- © H _ _ I — I — — — — —I— I 1 LN __- J LJ , I I ° OMM 0 ® I ® 0 30033P 1 I Iu REVISIONS: 1 I I I $ I --- — — — — — ' I - — — — — — - P . 4 ELEJ I I© 3002 I { 1 0 Ma I � I-3c1 1 � I I I I I-8c L 4 322 I 323 , ��rp PR 0 � I NEF 5 9P 5 0 � I 20 G IV - --- I qFr y 15, LYN N S� ® --- I EXPIRES: 06-30-2016 PROJECT TITLE: R . 8 1 0 - - - - - - - - - - - t�g - � - - - I I o STAIR #2 I q s 3006 W0 t� I I I I I-4c A I I 1HR F FB 1HR FB 1HR FB -T1 ©—� T - - - 95 s 85 es �S 85 - T I I I I • MATCHLINE 1/M2.3a U 1-2 1-2 301 302 N 7 CE 1J14 1 � 19 or o ©© _ 1 I - ©� -i o ►--� CD-1 9x9/2 TYP. 5 I O B Q THIRD FLOOR PLAN BUILDING "B"- HVAC A x zo M2.3b 1/8It = 11 - 011 KEY PLAN N O o SHEET TITLE: THIRD FLOOR i HVAC PLAN BUILDING "B" DRAWN BY: SHEET: Q w > Q PROJECT#: LsXX M2.3 b Q � DATE: 1 GL X M � or�io°Oo O M J �4 •va y 13 21 1 . 1 . 22 va I I � I - - - - - - - - - - - - - - I � vii �ii jet 2 2. 9 3 5 A. 6 - - �I--I - - - - - - I - - - - - –,— - - - - - - - - - - - - I - - - - - - - - - - - A. 6 ENGINEERING i I I I I I I I I Job Number: Contact: I I 14-0239 Jeff Stauffer I I y — — — — — — — — — — — — A. V THIS G DA S THEREON esign a ep Phone: JLS (503)363 2334 I I I I I I I I -T I ' I I ' SHALL NOT BE DUPLICATED,USED OR — TH DRAWING TA AND DESIGN I I I DISCLOSED TO OTHERS FOR PROCUREMENT OTHERWISE OTHERWUTHD TRACT, WITHOUT PERMISSION OF I i I J LJ I I I I o f ( ALL REPRODUCTIONS SHALL BEAR I I THIS NOTICE. I I I I I I I i I A-6e --- --- El � A-6e 349 � I I I � I I I I I I I I 344 I I LJ - I EF-371-T I i I EF-35 I IL LI SR-1 225 0 I L: EF-36 12x6 LI 1 A-4cr CD-1 175 A-4cr ® O I 348 9x9-2 TYP. 3 i i 345 I I I I I I I – – – – – – – – – P 3 – – – – – – – – I – – – – – – C e Cn I I — — — — — CA) I rn , --- , LAUN. i I --- 1 307 I 1 1 A–lb A-3cr I ITV A-3cr 339 Cn //�� A-3a 334 ® ® 335 I �J A CO DOR ¢ A-2 ® � – i 346 A-2b I - i - I ® A-2 i 350 s i ® I , 337 i G i G 3 E6: 343 IT /PHONE i O ' ' � I i I PHONE/ ELEC STOR DATA �`� �'� ' + I DATA ELEC _ 1HR FB 3096 94 3092 +–_ o I 3071 1 3 3 2 3075 e— —0� �JHt—a� —i s� a - —� -- - o a STAIR #7 - - - 8�� - - - - 8"QJ — -I - - - - - - - 8 - - STAIR #6 I E�flAIR i 6 0 I 16x8 L. 8 0 14x8 L. 8 16x8 L. CORRIDOR 8"0 24x8 L. I 3077 I REVISIONS: y � CORRIDOR I I ._ 8"0 ._ FSD (26x10) J (18x10) 3091 10,10 0!4 1 - f(16x10) f(18x10) 3069 ~ 6' 1 Fa Ns 28x8 L. NR HR I HR NR !.R C• 6 � e I + 10"fd X - - - - - - - - - - - - - - � 1 -- - ---- ---- ---- ---- - +-- � 1 ® -I- - - - - - - - 8J 2iH l STORF0ei�D — — 9x9-2 P. 2 EC 14x14 L. q �" q u , I°' 4"O — — ki 6 f�1 , I o I 9 (16x16) 3095 I STOR. I , i i I 70 072 EF-39 0 >< 3093 i O e O i L L I i 30 RR-1 900 351 I I( ® I I iI — 11 6 BA-2b G []0) I ®1 W I I ® A t , 342 F-23 p PROF-22 012x24 248L. ® I --- t A-2 26xFss I I347 A A II I 1 I I I ' ��G'INEF 5 A-1 b I i CD-1 12 + 9x9-2 TYP.2 --- 338 co ___ A5 9P --i ---- i , ---- r A-3cr A-3cr I , 333 I 332 I a) 0 I I 0 I Y 15 20 I I 9 , J D — — — — — — — — — — — — - - - - - - - - - — — — — ' o — of — — — — — — — — — — — — — — — — — — — D FrCYNNS�P 0 EXPIRES: 06-30-2016 A-4cr CD-1 A-4cr 9X9-2 I PROJECT TITLE: CORRIDOR0 340352 EF-38� 3Q0 �70 i CD-1 150 1 IL -I --- --- 9x9-2 , --- , LI--I� , J I --- � � 7 1 l 1 14 15 16 18 I I I I I A-1 A-1 A-6e 353 __+ — 2HRFRAFW HOiRfW 2HOiRFW 2H W = 2 R FW 2FMRWW 2FORWW 2FM VW 2FERNW — U+ I I l m I LL I ` T T- m z STAIR #3 I I I 1HR F B 1HR FB 1HR FB 1HR FB I I I I I y � O D Hw II - - - - - - - - I — . 2 a Q MATCHLINE 1/M2.2b ( I Mali I-3C2 � � ® a - _ - - - - - - - - - - - H . 8 C o � I O O J – – � - - - - - - - - - - - –I SHEET TITLE: B THIRD THIRD FLOOR PLAN BUILDING "C"- HVAC HVAC PLAN FLOOR BUILDING "C" M2.3c 1/8" = 1' - 0" ADRAB sY: SHEET: Gl W PROJECT Q KEY PLAN 13� M2.3 C Q � DATE: a Q X i co ■ NOTES MM w con 0' 110 ' z 1 3"0 EXHAUST DUCT DOWN IN WALL BELOW AND CONTINUES �� o M 00 ■ = O ON UNIT PLANS. DUCTS COMBINE AND TERMINATE ON ROOF ti)M . WITH BROAN 634M. o o O2 4"0 EXHAUST DUCT DOWN IN WALL BELOW AND CONTINUES = k I I ON SHEET M2.3a. DUCTS COMBINE TO 6"0 AND TERMINATE � Q ION ROOF WITH BROAN 437 ROOF CAP. SEE DETAIL 13/M4.2. M a w L i J L — — -, ■ 0 4"0 EXHAUST DUCT DOWN IN WALL BELOW AND CONTINUES ON UNIT PLANS. DUCTS COMBINE TO 6"0 AND TERMINATE I ON ROOF WITH BROAN 437 ROOF CAP. SEE DETAIL 13/M4.2 I I ■ O4 4"0 DRYER EXHAUST DUCT DOWN IN WALL BELOW AND - CONTINUE ON SHEET M2.3a. TERMINATE ON ROOF WITH I BROAN 636 WITHOUT BIRD SCREEN. • 0 4"0 DRYER EXHAUST DUCT DOWN IN WALL BELOW AND ■y — — I CONTINUE ON UNIT PLANS. TERMINATE ON ROOF WITH BROAN 636 WITHOUT BIRD SCREEN. O ■ O 0 PROVIDE MOTORIZED DAMPER AT TOP OF ELEVATOR SHAFT. DAMPER NORMALLY CLOSED AND TO OPEN ON CALL FROM ®®® • FIRE ALARM OR POWER FAILURE. SEE DETAIL 13/M4.2. 0 O 2,Y2" COMBUSTION AIR AND VENT TERMINATES ON ROOF ovaTYP. 3 0 0 WITH FURNACE MANUFACTURERS CONCENTRIC ROOF KIT. I 3 IL�JJ ■ COMBUSTION AIR AND VENT DOWN IN WALL AND CONTINUES U . 4 - - ON SHEET M2.3a. I O I ❑ ■ --- 0 24x18 L. (26X20)OSA DUCT DOWN AND CONTINUES ON ------- ------ ---------------- - - SHEET M2.3a. I I ---------------L_ _ _ _ _ _ — g 12x18 L. (14x20)OSA DUCT DOWN AND CONTINUES ON SHEET 3 ■ M2.3a. 1 I 1p 4"0 EXHAUST DUCTS DOWN IN WALL BELOW ON SHEET O3 ■ M2.3A. TERMINATE ON ROOF WITH BROAN 634M ROOF CAP. ❑ I 11 4"0 EXHAUST DUCTS DOWN IN WALL BELOW ON SHEET M2.3A. TERMINATE ON ROOF WITH BROAN 634 ROOF CAP. — — — • 12 SPLIT PLENUM DROP THROUGH TRUSS CHORDS AND Jit I RECOMBINE. I _ I — — --- I ENGINEERING I I Job Number: Contact: ■ 14-0239 Jeff Stauffer -- -- Design By: Telephone: I AS (503)363-2334 THIS DRAWING DATA AND DESIGNS THEREON J SHALL NOT BE DUPLICATED, USED OR DISCLOSED O OR OTHER PURPOSE,EXCEPT PROCUREMENT OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF v - I �- • __ _ _-_ ____--_-_____ - - - - - 2 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE.x MATCHLINE 1/M2.4b //70'0 ;7r( CU N i ■ I I I \ / \ X. 4 I I I I I I 0 O — J RV-9 12RV-7 6 REVISIONS: ■ RV-8 I i I I , \ �/ ' TYP. 3 J I - - - - - � - - - - - / 3 I I , I � / I HR � O , \ _ _ J � PROF O O - �[ i O 0 1 I / " \ H 3 Y15 r(YNN SSP • �/ \\ i i TYP. 3 ,-� 3 ' E 30 EXPIRES: 06- -2016 / > , 1 ® 3 \/ < , I ; I I j , � < PROJECT TITLE: \/ I F163 1 � 3 � 3 I - � 23 O l i 0 \ �� " ■ 0 ' — — — — — — — — — — — — — — — — — — — ® /i 1 TYP. 3VI O O " X00 1 0 TYP. 3 N I ■ 11 � C + f ® TYP. 3 \ 0 2 I--� Z I \ / \ - - 1 - ---------� TYP. 3® L------- z I � � 10 ®❑� I � � � I I B � � W N O o kn I SHEET TITLE: A ROOF HVAC PLAN I � ROOF PLAN BUILDING "A"— HVAC BUILDING "A" KEY PLAN DRAWN BY. SHEET: 1\�!�Aa 1/8" 1 1 Oil PROJECT#: 1 . 1 . M2.4a JI H XX � � DATE: i x I i C 3 ) I CKIVIIIVH I t UKT CK r-AriHUJ I UUtt,I J 111,4 muur VVI 11-1 t5KV/11V 636 WITHOUT BIRD SCREEN. DUCTS CONTINUE DOWN ON SHEET M2.3b. c*I Cn ~ M O4 DOUBLE WALL FIREPLACE FLUE TERMINATES ON ROOF WITH W `" FIREPLACE MANUFACTURER'S APPROVED VENT CAP. FLUE 7� M 00 CONTINUES DOWN ON SHEET M2.3b. �! O00 OPROVIDE MOTORIZED DAMPER AT TOP OF ELEVATOR SHAFT. o O o DAMPER NORMALLY CLOSED AND TO OPEN ON CALL FROM ✓ j FIRE ALARM OR POWER FAILURE. SEE DETAIL 13/M4.2. to O6 3"0 EXHAUST DUCTS TERMINATE ON ROOF WITH BROAN 636 In v' a w ROOF CAP. DUCTS CONTINUE DOWN ON UNIT PLANS. 7O 4"0 EXHAUST DUCTS TERMINATE ON ROOF WITH BROAN 636 ROOF CAP. DUCTS CONTINUE DOWN ON UNIT PLANS. J O4"0 EXHAUST DUCTS COMBINE AND TERMINATE ON ROOF WITH BROAN 634M ROOF CAP. DUCTS CONTINUE DOWN ON SHEET M2.3b. ! ' I ova I I 1 �1 14 15 16 18 p I I I I IL RV-3 O-J I I O I I I I ( I ' • — 2HR 2HR FW 2HR 2HR FW 2HR FW 2 2 R FW I 2HR FW 2HR FW HR FW 2HR FW 2HR FW 2HR FW ( RV-4 E I E I v� I 2 II I I I 2 2. I I I O IL � I 8 - G fd 10 � - MATCHLINE 1/M2.4c 4 I I I i I x18 H . 2 30 I I I 3 „0 jet � I I � 7i I I ENGINEERING Number: Contact: H g Job Num I ; I 14-0239 Jeff Stauffer I Design By: Telephone: J — — — — — —t— ; I (503)363- _--_._ ___.__.. __--, AS 2334 RV-5 THIS DRAWING DATA AND DESIGNS THEREON I I I SHALL NOT BE DUPLICATED, USED OR RV-6 DISCLOSED OTHER PURPOSE,OEXCEP EXCEPT OTHERWISE AUTHORIZED BY CONTRACT, 1 I WITHOUT PERMISSION OF 8" 7 I I i O I I fI 3110 16110; I — ALL REPRODUCTIONS SHALL BEAR 20 THIS NOTICE. i 1 I I I I ' f l I 18x18 i 4 6 L -- ___ ______ ._............ ___ ___ K - - - - - - - i I n L 2Y2'0C ---- I I I I I 4 2 � I LJ I III I I SLI _ I I f 3"0 I I CM I ' - - ' ' ! ' - I - - - - �- - -I I i � � I 1 I i -- -- -- ----. -- -- ------- ------ ---- ------- - -1 I I N L J - - - - - - - - LJ I ' I I I I I I I I �7 I I I P 4 6 F- II REVISIONS: U I � I I I I I 3 I I P . 4 - - - - I I I I I I I I I L ' ' I i ' �C��p PRO,cFS,s INEF 1029 - - - - - - 4 I - - - I 5 9P I 7 20 T `y G I � ;7) 15, 2 J� I I y CYN N S(P i 3 i EXPIRES: 06-30-2016 I I I PROJECT TITLE: I I I I S I I ' I I I I f 3„O I I I I - - - - T I r I � U MATCHLINE 1/M2.4a I n i � N 7 C� I ' Li o � B W o a a A o KEY PLAN SHEET TITLE: ROOF ROOF PLAN BUILDING "B"- HVAC HVAC PLAN BUILDING "B" DRAWN BY: SHEET: Gl > PROJECT#: 2•4b Q 13xx E� LYi DATE: a X M NOTES rM 4 14x20 OSA DUCT ELBOWS DOWN AND O1 4"0 EXHAUST DUCTS COMBINE AND U TERMINATE ON ROOF WITH BROAN 634M ROOF CONTINUES ON SHEET M2.3c. 0 C)vim-,,o CAP.DUCTS CONTINUE DOWN ON SHEET M M2.3c. O 16x26 OSA DUCT DOWN AND CONTINUES ON n y C SHEET M2.3c. s Q 2 2}S'COMBUSTION AIR AND VENT TERMINATE O 18x36 OSA DUCT DOWN AND CONTINUES ON t/] ON ROOF WITH FURNACE MANUFACTURER'S SHEET M2.3c. CONCENTRIC ROOF TERMINATION KIT. COMBUSTION AIR AND VENT CONTINUE DOWNO 4"0 EXHAUST DUCTS COMBINE AND J ON SHEET M2.3c. TERMINATE ON ROOF WITH BROAN 437 ROOF OTERMINATE DRYER EXHAUST DUCTS ON ROOF CAP.DUCTS CONTINUE DOWN ON UNIT PLANS. WITH GROAN 636 WITHOUT BIRD SCREEN. O DUCTS CONTINUE DOWN ON SHEET M2.3c. 44x44 OSA PLENUM. SPLIT PLENUM AT TRUSS CHORD LOCATIONS 22 O O �M I -------------- ------------- I et I I I I I A.6 I ? T TI = I I = ENGINEERING I I I I A.8 I }-_ _� _ _ _—_ _ _ _ _ _—_ _ _—_ _—_ _ _T _ _— I _�_ I _ _ Ycr. Job u o : 14-0239 11C.N'."uffer Ueaign B Telephone: I 1 I I I _ – – – – – AS (503)363.2334 ------------ - —————————————————————————— ' MD THIS I I I ✓ I __ _ _=_ _ , r I J 'OTO 0THER5 FOR PSEOW 1I1d RECN SHALLNBEDUPUCATEDDOCR DISCLOSED OR OTHER EXCEPT PTAS OB - --_ _ O7NFRMAURRE BY CONTRACT. I taour PERIUMoR OrJ �J I I I ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. II I I I O JL s" L LJ - I I I -{I 4'0 I I I Fw I - - ---------- -------- I o —I � 1 oc -- Pi3a I® 3 — I O }•� r I L-- -- -- I I I I I O I I IILII I*�Iw I O I I I I I I I I I I I 7 ' I 410, i i , 4"0 RV-12 8 ; ( O 6"0 I° O i i 7 a 1 I ; I I RV-13 8 J I I I I I ® I ; I O I I I I � � II -- ----------------J - --I ------------------ ------- -- ------------------------------------------------------------------- ------ -- ----- ------------ - --J REVISIONS: ----------------------------------------------- - ---- ------------------ -- -- ----- ---- ------- -- ------------------ -- - -- ----- - - - - - - - -1CI -6��- -®O® -�L - FF-- O 7 Oa O F-4'0 O -— I I I I ' 4"0 4 � I I I I 6"0 1 OI I I , i i I O I I Ep PROF NGINEF S'iO2 OD 4.•0 ------ — O O i � �� 5 9P v O r- I I I ®3C i 5, lYI2��3 chi SPO LYNNS EXPIRES: 06-30-2016 6"0 ; 4� i I O I i I O PROJECT TITLE: I I I I 4"0 TIO – -- --- 7 14 15 16 18 F— — 1 I 6"0 I I I II I I I I I I I I L J I I II II I E – 2HR 2HR FW 2HR 2HR FW 2HR FW RFW 12HR FW 2HR FW HR FW 2HR FW 2HR 2HR FW I I 1 II II E F �- I - - - - - � - --- E0-- I lir - - -- - - �I /-�,I II I I -�- - + Zj II II I ' G CIO O H.2 „ 2 3 5 MATCHLINE 1/M2.4b I I 21 1 . 1 . 22 1 I I ' I B SHEET TITLE: ROOF ROOF PLAN BUILDING 'C" — HVAC HVAC PLAN M2Ac 1/8"= 1' -0" BUILDING"C" 0 A DRAWN BY: SHEET: LU PROJECT= KEY PLAN 13- M2"4C DATE: x �M M EWH-AC o cn 000�'n O ❑ ❑ ❑ EWH-A 2 p X v PTHP-A 4"0 EF-A 3 ❑ 101 11-1L—J ❑ i PTHP-A 4 J 4"0 1 i i 2 I TF-A j i TF-A 4 EWH-A M I j O 2 _J PTHP-A EWH-A I ❑❑ O EF-A 3 ❑ 5 5 �- TF-A E O TF-A 77 ❑ 0'ri, EF-A 3 � EF-A 3 O ; ° O LE ° 4.,0 I o ❑4.,g ` ❑ 1 o et 4 O ENGINEERING Job\umT,rr: C 1 T 14-0239 Hal Spence ENLARGED TEJA4 HVAQ PLAN 2 ENLARG ITEEA-Vi+MC PLAN 3 ENLARGE �J�TI�A-?�/AC PLAN 4 ENLAR 5WTE A-2I�HVAC PLAN Design By: Telephone: HMS (503)363-2334 — SCALE: 1/4" = 1'-0" — 1 SCALE: 1/4" — 1'-0" — SCALE: 1/4" 1'-0" — SCALE: 1/4" = 1'-0" TMISHALLL DRANOT DATA AND OR M3.1 1/4"- 1 M3.1 1/4' - 1 - M3.1 1/4' - 1' = M3.1 1/4' - 1 DISCLOSED TO OTHERS FOR PROCU�MENT OR OTHER PURPOSE,EXCEPT AS OTHERMSE AUTHORIZED BY CONTRACT, MTHOUT PERMISSION OF JET INDUSTRIES,INC. 1835 SILVERTON R0. SA M OR 9-1 M.(503)m3 M.(5031386fIS8mccw C=;S cCBSQ586T ALL REPRODUCTIONS$HAIL BEAR THIS NOTICE �❑ 4 PTHP-A 4"0 PTHP-A I EF-A 3 I ° I 0 O O V-IV O ❑ ❑ TF-A EWH-A OLL O EWH-A i �' ❑ O O O EF-A 3 8 EF-A 3 EWH-A ❑.,0 2 TF-A E PTHP-A 2 I EF-A 3 O TF-A 4 REVISIONS: PTHP-B i /tom//1 I Q❑ I' Q �0❑ ❑ i❑ ® O O 5-- ENLAR4R15PJTE VAC PLAN 6 ENLARGEA AC PLAN 7 ENLA � q�TFAP�- �NVAC PLAN PEDPROF�cS ;I �5��AGI N EF `S/D M3.1 1/4"= 1' SCALE: 1/4" = 1'-0" �.i1/4'I= 1' SCALE: 1/4" = 1'-0" M3.1 1/4"= 1' SCALE: 1/4" = 1'-0' e� 5 9P ¢y - G q � x)'15, YNN FyCSIP I -�I ❑ EXPIRES: 06-30-2016 EWHA 00 1 �� PROJECT TITLE: NOTES 4 � O J"CONDENSATE DRAIN DOWN IN WALL.TERMINATE AT 6-AFF PTHP-A O ON FIRST FLOOR IN LANDSCAPE AREA. O2 ROUTE DUCTWORK IN JOIST SPACE. ( 4"0 U OSEE DETAILS 2/M4.2 FOR CEILING MEMBRANE PENETRATION O 1 ❑ 2 PROTECTION. r ❑ O4 4"0 EXHAUST DUCTS UP IN WALL ABOVE. r O5 INSTALL PER LOCATIONS INDICATED ON DETAIL 12/M4.2. ❑ 'j EF-A 3 O3"0 EXHAUST DUCT UP IN WALL ABOVE.TERMINATE PER I ❑ U DETAIL 12/M4.1. O7 4"0 DRYER EXHAUST DUCT UP IN WALL. PROVIDE DRYER I ( i BOX AND LINT FILTER BOX. CONTINUE ON FLOOR PLAN TF-A I + SHEETS AND TERMINATE ON ROOF. SEE ROOF PLANS FOR v LOCATIONS. O8 TERMINATE 4"0 EXHAUST DUCT ON EXTERIOR WALL WITH PRIMEX WC4 WALL CAP. ❑ Q Li I O . r Q i; ❑ � Q Z q i �D a a ° O z "0 I W /02j: a N � 3 El�t i I PTHP-A o OILEI o ED 3 EWH-A SHEET TITLE: ENLARGED HVAC UNIT PLANS A 8 ENLA TSA-4-Q-ri-HVAC PLAN 9 ENLAftGIWITF--)�-Qe HVAC PLAN DRAWN BY SHEET: M3.1 1/4"= 1' SCALE: 1/4" = 1'-0" M31 1/4"_ SCALE: 1/4" = 1'-0" PROJECT t: F 13- M3.1 DATE. Q X 2 M Vl EF-A 3 PTHP-B 2 4"0 L PTHP-B --j T coo 0�0 GEF-A 3 1 i PTHP-B D O O PTHP-B PTH P-B 4"0 2 Jet ii ii0 EF-A 3 F- ❑ 14�.2,19 1. ENGINEERING J"b Contact: ! "": .11., I D..iS g.By: TIephone: F—LXI I 1 JL1(503)363-2334 0 THIS DRAMNG DATA AND DESIGNS THEREON SHALL NOT BE DUPUCATED,USED OR 4"0 2 DISCLOSED TO OTHERS FOR PROCUREMENT 4"0 2 0-- OR OTH PURPOSE.EXCEPT AS 4"0 OTHERWSE"AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF jALL REPRODUCTIONS SHALL BEAR THIS NOTICE. 7 "aD&ITEZJ-H&C PLAN UITE7Z--'Fa-11V;k PLAN 'TCALE: 1/4" ((7N"GaDiIJITZZJB aV�C PLAN U1TE7Z-cd PLAN \V"SCALE: 1/4" 1'-0" \:yTCXLE: 1/4" A '17`2 "ScALE: 1/4" PTHP-A F9 ❑❑ t_ EWH-A Ij IIPTHP-A 'FF'= O i--i i �Ij ❑ CE �❑ j i TF-A EF-A 3 O �% ❑ - - Zvi REVISIONS: jI El 4"0 EF-A 3 5 ( ❑ !) 40 2 ❑ � -1 EWH-A 2 4"0 TF-A 4"0 2 ❑ ❑ ❑ O Q����NGINE�csS�ov 4"0 ===,A f 2 4%=A PTHP-A ❑ G PTHP-B y 15,2: tYNN FExPFREs.- 06-30-2016 IV PROJECT TITLE: F (6�DELIITIZZ-7i2 42 PLAN 0 SCALE: 1/4" ' UITEZ--A3 PLAN \� TTCALE: 1/4" = 1'-0" 7- 00 J NOTES C, Ol J"CONDENSATE DRAIN DOWN IN WALL.TERMINATE AT 6"AFF ON FIRST FLOOR IN LANDSCAPE AREA. OROUTE DUCTWORK IN JOIST SPACE. SEE DETAILS 2/M4.2 FOR CEILING MEMBRANE PENETRATION PROTECTION. 4"0 EXHAUST DUCTS UP IN WALL ABOVE. 4"0 2 INSTALL PER LOCATIONS INDICATED ON DETAIL 12/M4.2. 0 C) 3"0 EXHAUST DUCT UP IN WALL ABOVE.TERMINATE PER o DETAIL 12/M4.1. 4.0 DRYER EXHAUST DUCT UP IN WALL. PROVIDE DRYER Q > BOX AND LINT FILTER BOX. CONTINUE ON FLOOR PLAN 0 P, SHEETS AND TERMINATE ON ROOF. SEE ROOF PLANS FOR LOCATIONS. LII�LIITL--ge-16Aa PLAN O TERMINATE 4"0 EXHAUST DUCT ON EXTERIOR WALL WITH V21TCALE: 1/4" PRIMEX WC4 WALL CAP. \�VTCALE: 1/4" 1'-0" SHEET TITLE: ENLARGED HVAC UNIT PLANS DRAWN BY: SHEET: PROTECT#: 13- M3.2 DATE: X NOTES =n;; n O1 4"CONDENSATE DRAIN DOWN IN WALL.TERMINATE AT 6"AFF24 O M ON FIRST FLOOR IN LANDSCAPE AREA. kn 0 M^ O2 ROUTE DUCTWORK IN JOIST SPACE. o O o OSEE DETAILS 2/M4.2 FOR CEILING MEMBRANE PENETRATION N p X PROTECTION. v c,3 2 M V1 CL Lr, 4O 4"0 EXHAUST DUCTS UP IN WALL ABOVE. O5 INSTALL PER LOCATIONS INDICATED ON DETAIL 121M4.2. O3"0 EXHAUST DUCT UP IN WALL ABOVE.TERMINATE PER DETAIL 12/M4.1. yew O4"0 DRYER EXHAUST DUCT UP IN WALL. PROVIDE DRYER BOX AND LINT FILTER BOX. CONTINUE ON FLOOR PLAN �y SHEETS AND TERMINATE ON ROOF. SEE ROOF PLANS FOR LOCATIONS. OTERMINATE 4"0 EXHAUST DUCT ON EXTERIOR WALL WITH PRIMER WC4 WALL CAP. ova EF-B PTHP-A EWH-A EF-A 3 O TF-A PTHP-A O O •� �� � I I C PTHP-A O L� Jet. DENGINEERING O EF-A 3 W acl Jnb ga Hly: : cn]1ph: 14-0239 Jeff Stauffer Desigo Hy: Telephone: \� O AS (503)363-2334 EF-13 EE--TT THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED,USEDliE OTHER PURPOSE.E.BY CMTR(Mt © $ I - DISCLOSED(ITHER OTHER R AUTHORIZED FOR EXCEPT AS PROCUREME.T 3"0 G� WITHOUT PERNISSSON OF 11L � (COD) 7 3'0 3'0 © © O I O Q ... © -- -- _ ALL REr4:ooucna+s sxuL BEAR Ltj-- - EF-B nns Nonc1 O EWH-A EF-A 3 i TF-A O O � 2 4"0 4 4"0 2 1 TF-A o O O ° I.I i (� �6DLSUITf=T-2 f�AC PLAN 2 ENLARGED SUITE I-2a HVAC PLA SUITE 1 - 2c 3 ENLARGED SUITE 1-3 HVAC PLAN SUITE I a �b�ILIT�3c,IHVA6CA 1J 1/4n = 1,_ \,!!.3,/1/4"=r SCALE: 1/4" = l'—O° M3.3 114•l' SCALE: 1/4" = 1' �D.3 114•=r REVISIONS: EF-A 3 EF-B I EWH-A PTHP-A PTHP-A p PROFc�s 1 TF-A TF-A O 3"0-\ b GI SIP /0�9 PTHP-A _ I G EF-A 3 q 'Y15, O O LYNN S ' O 4"0 2 TF-A EWH-A EXPIRES: 06-30.2016 © O PROJECT TITLE: ❑ � � 2 C�7 Wa Qi 40 _, �a 5 ❑ I_� 3"0 © + U EWH-A � � + ❑ 5 TF-A O� �� `�/ y EF-B f-- EWH-A PTHP-A Q EF-A 3 A NJ zm y YY 2 4"0 1 IE9, W M Ll Eli 3'0 4"0 2 O 3"g SHEET TITLE: z OENLARGED 4 HVAC UNIT PLANS 2ELNSUIT E 1 - 3c2 DRAW4 BYSHEET: " _ , -o /� C �°ETI6T� G M3 3 Lj I-3c2 HVAC PLAN UITETd MVAC PLAN �6DLSUITETaa PLANUI c PLANPRO ECT> .. 11 SCALE: 1/4" 3 T = 1,_O„ Q M3.3 114"=1' 1TCALE: 1/4" = 1'-0" SCALE: 1/4 = 1'-0 DATE: V� X Q lL' I m 2x4 FRAMED, NON-BEARING, NON-SHEAR NOTES- PIPESWALLS. COORDINATE w/MEP DUCTS AND PIPES OS INSTALL PER LOCATIONS INDICATED ON DETAIL o O t"CONDENSATE DRAIN DOWN IN WALL.TERMINATE d �m. 12/M4.2. C o m AT 6"AFF ON FIRST FLOOR IN LANDSCAPE AREA. o C)�a o 6 3"0 EXHAUST DUCT UP IN WALL ABOVE.TERMINATE � ai 2O ROUTE DUCTWORK IN JOIST SPACE. PER DETAIL 12/M4.1. O3 SEE DETAILS 2/M4.2 FOR CEILING MEMBRANE4" M 0. PENETRATION PROTECTION. O 0 DRYER EXHAUST DUCT UP IN WALL. PROVIDE DRYER BOX AND LINT FILTER BOX. CONTINUE ON O 4"0 EXHAUST DUCTS UP IN WALL ABOVE. FLOOR PLAN SHEETS AND TERMINATE ON ROOF. SEE ROOF PLANS FOR LOCATIONS. J OTERMINATE 4"0 EXHAUST DUCT ON EXTERIOR WALL WITH PRIMEX WC4 WALL CAP. ` y EWH-A PTHP-B PTHP-A PTHP-A w O 3"O O 4"0 2 2 4"0 - ° © Z a a O ! 1\A et TF-A !I EWH-A ENGINEERING Job Number: Contact: �� 14-0239 esiI Jeff Stauffer j ! Dgn By: 1'clephone: Li I PTHP-B I JLS (503)363-2334 THIS DRAYNO DATA AND DESIGNS S THEREON SHALL NOT BE HERS FOR P OCU OR ME DISCLOSED E OTHERS EIXt PROCUREMENT OR OTHER PURPOSE,EXCEPT AS o NERYAUTHORIZEDBYCONTRACT, WYADiWT PERMISSION 6 N PTHP B j i Q EF-B !i ALL REPRODUCTIONS O SHALL REAR THIS NOTICE. Qw EF-B EF-A 3 0 DtEF-A 3 © © 2 4"0 ° O © ©; PTHP-A 4110 2 0 41'0 2 3"0 O � T-0 Ol O O I CC I C (` C ��DI SUIT�T3 OAC PLAN EE�11JAb2I6 DL IJIT�T3a PLAN CacI&I4T-6c(6 MAI PLAN "" 4 1CkiLE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 'g'CALE: 1/4" = 1'-0" REVISIONS: PTHP-B PTHP-A O I j I PTHP-A u ! U �PEp PROFFS PTHP-6 b GI 9P s/o2v O I G 15, PTHP-A o ` 0 � GVNN SSP uj EXPIRES: 06-30-2016 A PROJECT TITLE: i. _ FA I 0 I� 4"0 2 ° I N rti TF-A E- EWH-A w EF-A 3 Q Q O O 1 TF-A j DW EF-A 3 PTHP-B Y Q - Z 4„� 2 EF-8 > O w D I O oO U Z EF-A 3 _' z _=� 0 w O° 3"0 _ (� 4„0 2 3„O © EF-B El ❑ ❑ U -- f-; o N MOM O OSHEET TITLE: ENLARGED HVAC UNIT PLANS C c I C C EI BY: SHEET: L ��D IJITII-6c2V� LAN NNL"L�D IJITILT-ZL\&C PLAN �_ f F��IX SUIT�T�e A�PLAN PROJECT R: Qw kt' 'TCALE: 1/4” = 1'-0” 1TCALE: 1/4" = 1'-0” 1TCALE: 1/4" = 1'-0" 13- M3.4 H F n DATE: a a. x �M N •--,M LtlnnVl r M No 00 O MOO In �M I d) it O �O o O v3 'n al ❑>< EF-A 3 c�+3 _r_ EWH-A J Om PTHP-A 4"0 2 EF-A 3 4 O � 3"0 Q 3"0 EF-B 2 4"0 �1 © 3 EWH-A EF-A c Q 0 0 z 5 i PTHP-B TF-A P4"0 2 O OO EF-A 3 1 ❑ T TF-A J ENGINEERING PTHP-B I 14 2 El Job"-"r b,,: C"„ta.t: 1 c i gn By: T eph. er Oj JLS 1(503)363-2334 THIS DRA'MNC DATA AND DESGNS THEREON PTHP-A O¢ ❑ DISCLOR E OTHERS URPO FOR EXCEPT/�l I OR OTHER PURPOSE,BY CON AS SHALL NOT BE DUPUCA ED,USED OR 4"0 2 OTHQtIMSE AUT PERMISSION IO CONTRACT, a"0 I NIhiWT PFR41590N aF O TF-A oALL REPRODUCTIONS SHALL BEAR THIS NOTICE. © O © © 3"0 O 1 PTHP-B El El , 4"0 2 EF-B PTHP-A O EWH-A O EF-A 3 EN �JDiUAT7etF PLAN �JLUITLT7a-i��PLAN 7 A ,bLFiUAT7b��PLAN M s v�CkiLE: 1/4" = 1'-0'• 1'!WLE: 1/4" = 1'-0" SCALE: 1/4" EF-A 3 TF-A 1 O REVISIONS: EWH-A I El 0 OPTHP-B �/ 4"0 2 PTHP-A O 4 4"0 2 EF-A 33 EWH-A TF-A PEO t Ho F-I0 � �O � 5 GI 9P S/o�9 �` ©i O o ; G �q �Y 15,2��JF�� Ry SYN N SqP EXPIRES: 06-30-2016 i M 3110 EF-A 3 I�� D II_ PROJECT TITLE: ❑ 4"0 2 W 0 O EF-B i � 04 M EF-A 3 � O ❑ O O ElW Ea 1 4"0 23"O EF-B O TF A © 3"0 PTHP-A O U ' PTHP-B s EF-B N Q + O y I—I � � w � 2 4"0 4"0 2 I N W u Z PTHP-A Q PTHP-B O ❑ ❑ W v Z� o a O ❑ � EWH-A �,; > 3 z c) a a lV OMM O SHEET TITLE: a ENLARGED SUIT 1-8 HVAC PLAN 5 ENLARGED SUITE I-6e HVAC PLAN s ENLARGED SUITE I-8c HVAC PLAN 3.5\"!!.4,/114"= ENLARGED 1' M 1!4'=1' M3.5 1!4"=1' HVAC UNIT PLANS SUITE 1 - 8 SUITE I — 8a SUITE - 8c DRAWNBV: SHEET: 4 p SCALE: 1/4" = 1'-0" 5 SCALE: 1/4" = 1'-0" (L)TALE. 1/4" = 1'-0" PROJECTM LID 13- M . FDATE: V2 oc a a �M NOTES W �In O M 00 N CO M O1 III GREASE DUCT UP THROUGH ROOF AND TERMINATEo I,o Mo EF-K1.PROVIDE AND INSTALL(2)LAYERS OF 3M I FIRE o O..� WRAP. OHOOD BY OTHERS. M cn a W O14x6 TRANSITION TO 10x10 AND ELBOW UP.PENETRATE ROOF AND TERMINATE AT EF-K2. O5'0 EXHAUST DUCT UP.PENETRATE ROOF AND TERMINATE WITH GLOBE VENT. OEXHAUST DUCT ROUTED IN TRUSS SPACE ABOVE RATED CEILING. O10"CLEARANCE UNDER BEAM. OPROVIDE EXHAUST FAN WITH CEILING RADIATION FIRE `O DAMPER. !T� O22x22 L.(24x24)OSA DUCT UP TO MAU-1 ON ROOF. O31 L.(32x16)SUPPLY AIR AND 31 L.(38x16)RETURN va DUCT UP TO RTU-3 ON ROOF. D10 8"0 EXHAUST DUCT IN CEILING SPACE CONTINUES ON SHEET > M2.1 b. 11 TRANSFER GRILLES LOCATED IN NON-RATED WALL ABOVE /- DDOOR. F 1 12 TYPE I HOOD ENERGY MANAGEMENT SYSTEM TO ACTIVATE O = HOOD/MAU/EF-K1 WHEN ANY APPLIANCE UNDER HOOD IS ACTIVATED.EMS TO SHUT DOWN WHEN NO APPLIANCES ARE OPERATING. PQ WATER RISER RM SERV 1024 et 1025 dl0 `� ENGINEERING X21 21'x48' Ii 21k48' ii 5"0 14-0 39 ber. Jeff SWuRer 5„� Design By: Telephone: JLS I(503)363-2334 j 2t A AND 5 THIS SHALL NOT BETDUPLICATED,,USED ORDESIGNS 1 3 LF DISCLOSED E OTHERS FOR PROCUREMENT v OR OTHER PURPOSE,EXCEPT AS T CD-1 75OTHERMSE AUTHORIZED BY CONTRACT, 9x9- INTHOUT PERMlS51CN OF 2 -- '-�- 1023 -_{ EWH-K1 11 BEAM 021 N ALL REPROT CEONS IS NOTICE ALL BEAR (x EF-K3 ExHAUST FAN I f 21'x48 -�+ 121k48' 21k4 —4 Li + +r � � i ' EF-K4 I 24'x48' 'I 24k48' BEAM CURB PER MECHANICAL 42' I COUNTERRAI MG Mw. 4'CANT STRIP ALL SmES _ 28 LF 6 Ty, II _AND-MD - _L _ i L]7 c” �o tillX 16x6 L.(18x8) ,(' I f } I LXX I xmoi:- I i i rii ----- ----- I CD-, 200 F CM ,X I a l 12x12 ———— 92 G21 200 124 (24x12) 24'x48' \ 04 04 30Vof SLCPED BEAM I ' MAINTAIN 1 HR CEILING -. (2Y2))LAYERS OF 3M 615 PWS GillH-K1 12 (2 xl0 Fp -2/A139I ASSEMBLY(RC/GIP) PROVUE ICD-1 425 16GA IlUOIAD TIGHT GREASE ' 12x12-3 T42 7MIN. pUCC EITHERUGHT TEST OR IPREMN TEST. —----- — r� CRG-12850 - --_ - - 3 24k48' 22x46 —— 14x10 L. I.1 m CD-1 425 (16x1 2) 1 - =-I I -- -- - +--- ------ �� � I N x ' I ' 14x10 L. o not N I (16x12) 16x6 L. (18x8) - _ E REVISIONS: Sm FRAI E Npl Cb18us CD2 300 0 �LIE10 I I o P o 12x12-3 MAX 1 L--d � ji TG-1 --- 2"0 Ji^ Ln 36x6 TYP.2 11 v 12 0 N I Mw. I 24x8 L. I y �MPM3 FE I II FD i - - PED PROF I I KITCH Gi f ����� vvt:F - CORR- 10"0 11 019 � 15 36x6 TYP.211 I �CYNN S�PJ I BEAM ~ BEAM EXPIRES: 06-30-2016 PROJECT TITLE: � O ------------ I ECF �p c7 H U N + 2 KITCHEN RANGE/HOOD WALL KITCHEN PLAN - HVAC w M3.7 NO SCALE M3.7 114"= 1'-0" W y q i~ Z 0 0 y 0 N �yY O SHEET TITLE: ENLARGED KITCHEN PLAN HVAC DRAWNBY: SHEET: GJM > � A PROJECT#: H F 3" M .7 ¢, DATE: J a x �M �o 00 00 N i O M 00!ac) N O O cd L Q SHEET METAL DUCT. VOLUME DAMPER PER N1 ON TR I TR�1 "'o, NO TR I T�1 SPECIFICATIONS(NOT 1 24vAC j z4vAC j 1 14vAC j 14vAC ij J Z MOT COM Z HOT COM' y FURNISHEDW/SPIN-IN). 1 2 P1 P _ � 1 2 P1 P _ �V C7150B MIXED MIN.POSITION C7150B MIXED MIN.POSITION } 3 AIR OR C704SA ADJUSTMENT + } 3 AIR OR C7046A ADJUSTMENT } DISCHARGE DISCHARGE T1 T AIR SENSOR AIR SENSOR FLEXIBLE DUCT po -MAX 5'-0". 4 1 2 4 1 2 �� FO 012-IOVDC- AQ1 5 FO 1 5 IN DOOR AIR EXHAUST } CEILING. CONNECTAIR INLET OR OUTLET TO ELBOW ACTUATOR sBNsoR+ SO+ SO 3 O ACTUATOR S0+ SO 3 O Q AIR. I PER MANUFACTURER'S INSTRUCTIONS. ^ SR+ S EF EFl1J NDSE RAIR SENSOR+ SR+ S F1 EF EF1 TO H-1 4VDC C 7212 CONTROLLER OT0W7212 O C7400 U 620 OHM OUTDOOR 620 OHM AIR. AIR. r� INTAKE INTAKE I I 3 AIR INLET R OUTLET ROUND NECK OUTDOOR WTDOOR } RESISTOR AIR OUTDOOR } RESISTOR � _J ` � BRANCH DUCT NO SCALE ENTHALPYENTHALPY SUPPLY AIR FLOW. SENSOR OS SENSOR OO 12"MIN.ABOVE FLASHING. F/1 AVERAGE SNOW SHEET METAL BRANCH ACCUMULATION. DUCT WITH 1"DUCT I I O DIMENSION AS LINER OR FIBERGLASS 0 37" I SHOWN ON PLANS. I DUCTBOARD. ______________i ______________i HP CONV C I HP CONV C II I 6"MIN. VOLUME DAMPER. I PROVIDE WHERE L O Y1 COOL 1 j L O Y1 ' COOL 1 j INDICATED ON FLOOR PLAN OR E Y2 I E Y2 — Y2 COOL 2 SHEET METAL STRAP. I SPECIFICATIONS. AUX i AUX J STRAP HANGERS SHEET METAL PLENUM WITH — I — I T CLAMP. TO STRUCTURE. 1"FIBERGLASS LINING. G G HEAT 2 i G G HEAT 2 i Jet f I SPECIFICATIONS(NOVOLUME DAMPER T O/B FANHEA1 i OCB C Ea T 1 6"MIN. NECKWIDTH c C45° PLUS 2". FURNISHED W/SPIN-IN). DELAY MAIN DUCT. FDR I FDR I Job\urnbe:: �103t)313 RELAY I I f I DUCT DIA. R R G FAN L21 R R G FAN L21 14-0239ll FLEXIBLE DUCT-MAX 5'-0". I I Design By:EXHAUST INTAKE PLUS2". FDR I FDR I ®Ce6�Ys 34 / — — —_ Rc Rc R I Rc Rc R I AIR. AIR. ——— J SUPPLY AIR — _________L1jl(HOT) _______ ___________-I(HOT) THIS DRawNc DATA AND DE9avS THEREON SPIN IN FITTING. SHALL NOT BE DUPUCATED,USED OR THERMOSTAT HVAC EQUIPMENT THERMOSTAT HVAC EQUIPMENT DISCLOSED TO OTHERS FOR PROCUREMENT RETURN/EXHAUST AIR EQUIPMENT EQUIPMENT OR OTHER PURPOSE EXCEPT AS TH6220D TERMINAL STRIP TH6220D TERMINAL STRIP CONTROL BOARD CONTROL BOARD oTrEJtrnsE AUTHORIZED BY CONTRACT, MTHWT PERIAIS90N OF CEILING--/ CONNECT AIR INLET OR OUTLET TO PLENUM JET INDUSTRIES,INC. CONCENTRIC MAIN RECTANGULAR PER MANUFACTURER'S INSTRUCTIONS. ECONOMIZER CONTROL ECONOMIZER CONTROL M,CAC��,�6t FAXShI.E X11 awaAee OR 1 ROOF TERMINATION 2 BRANCH DUCT CONNECTION 4 AIR INLET OR OUTLET SQUARE NECK 5 WIRING SCHEMATIC 6 WIRING SCHEMATIC ALL REPRODUC THIS NONOICE.ALL BEAR TCE. NO SCALE NO SCALE NO SCALE 2 HEAT/1 COOL 2 HEAT/2 COOL NOTES: NOTES: NOTES: O FIRE RATED PARTITION.COORDINATE WITH O FIRE RATED PARTITION.COORDINATE WITH 1 O FIRE RATED PARTITION.COORDINATE WITH ARCHITECTURAL FOR FRAMING AND FIRE RATED ARCHITECTURAL FOR FRAMING AND FIRE RATED ARCHITECTURAL FOR FRAMING AND FIRE RATED 7 7 LINING REQUIREMENTS. LINING REQUIREMENTS. 2 6 LINING REQUIREMENTS. 1 O COORDINATE PARTITION OPENING,1/8"LARGER 1 O COORDINATE PARTITION OPENING,1/8"LARGER O COORDINATE PARTITION OPENING,1/8"LARGER THAN FIRE DAMPER SLEEVE PER FOOT OF WIDTH THAN FIRE DAMPER SLEEVE PER FOOT OF WIDTH 2 6 OR HEIGHT. 2 6 OR HEIGHT. THAN FIRE DAMPER SLEEVE PER FOOT OF WIDTH DUCT OR HEIGHT. 3 5 O PROVIDE SLEEVE 3"BEYOND EDGE OF PARTITION, 3 5 O PROVIDE 16"SLEEVE. 5 EACH SIDE. 3 PROVIDE SLEEVE 3"BEYOND EDGE OF PARTITION, 4O FIRE DAMPER FRAME ATTACHED TO SLEEVE BY ... ........... 3 FIRE DAMPER FRAME ATTACHED TO SLEEVE BY "" """"" MANUFACTURER. EACH SIDE. MANUFACTURER. S 4O FIRE DAMPER FRAME ATTACHED TO SLEEVE BY -- — O "S"TYPE DUCT CONNECTION DO NOT SCREW OR BOLT. CAULKING CAULKING 01 MANUFACTURER. I i I O 'S"TYPE DUCT CONNECTION.DO NOT SCREW OR BOLT. I ♦ i I APPROVED SHUTTER MATERIAL(TYP.). l ♦ f I MATERIAL(TYP.). I ♦ f I O ANGLE ALL AROUND SLEEVE MINIMUM 1"OVERLAP TYPE FIRE DAMPER. O "S"TYPE DUCT CONNECTION.DO NOT SCREW OR BOLT. 7 I ♦♦ /� I O ANGLE ALL AROUND SLEEVE MINIMUM 1"OVERLAP 7 `♦ f WITH WALL FRAMING.ONE INCH FILLET WELDS 5" 7 J( I WITH WALL FRAMING.ONE INCH FILLET WELDS 5" X I MAX.ON CENTER,OR 1/4"BOLTS 5"MAX.ON O6 ANGLE ALL AROUND SLEEVE MINIMUM 1"OVERLAP j f ♦♦ j MAX.ON CENTER,OR 1/4"BOLTS 5"MAX.ON DAMPER f ♦♦ CENTER.DO NOT ATTACH ANGLES TO WALL. WITH WALL FRAMING.ONE INCH FILLET WELDS 5" DAMPER ASSEMBLY. i I i I CENTER.DO NOT ATTACH ANGLES TO WALL. I ♦ I COORDINATE WITH DAMPER MANUFACTURER FOR I f ♦♦I COORDINATE WITH DAMPER MANUFACTURER FOR I ♦♦I APPROVED ANGLE SIZE AND GAUGE. MAX.ON CENTER,OR 1/4"BOLTS 5"MAX.ON ASSEMBLY. 8 4 �I CENTER.DO NOT ATTACH ANGLES TO WALL. APPROVED ANGLE SIZE AND GAUGE. O7 PROVIDE DUCT ACCESS DOOR.COORDINATE LOCATION COORDINATE WITH DAMPER MANUFACTURER FOR WALL GRILLE O PROVIDE DUCT ACCESS DOOR.COORDINATE LOCATION AND TYPE OF ARCHITECTURAL SERVICE ACCESS WITH REVISIONS: APPROVED ANGLE SIZE AND GAUGE. I AIR FLOW SD AND TYPE OF ARCHITECTURAL SERVICE ACCESS WITH q SD ARCHITECTURAL. OPROVIDE DUCT ACCESS DOOR.COORDINATE LOCATION 401 �_ 09 ARCHITECTURAL. OO OS DAMPER ACTUATOR.MOUNT EXTERNAL OF DUCT ON AND TYPE OF ARCHITECTURAL SERVICE ACCESS WITHO8 DAMPER ACTUATOR.MOUNT EXTERNAL OF DUCT ON DAMPER SLEEVE.BY DAMPER MANUFACTURER.24 VAC. 4 4 ARCHITECTURAL. DAMPER SLEEVE.BY DAMPER MANUFACTURER.24 VAC. 7 . O PROVIDE DUCT SMOKE DETECTOR WITHIN 5'-0"OF DAMPER. DUCT GENERAL NOTES: :�7 ................. FUSIBLE LINK DUCT O PROVIDE DUCT SMOKE DETECTOR WITHIN 5'-0"OF DAMPER. FUSIBLE LINK DUCT DETAIL INDICATES REQUIREMENTS FOR STANDARD ASSEMBLY. ASSEMBLY. FRAME INSTALLATION.REFERENCE SMACNA FIRE, GENERAL NOTES: SMOKE AND RADIATION DAMPER INSTALLATION GUIDE" GENERAL NOTES: 6 DETAIL INDICATES REQUIREMENTS FOR STANDARD DRAME INSTALLATIONETAIL INDICATES . STANDAR SMACNA FRE,D FOR OTHER CONFIGURATION REQUIREMENTS.COMPLY FRAME INSTALLATION.REFERENCE SMACNA FIRE, FULLY WITH ABOVE MENTIONED AND ALSO AHJ SMOKE AND RADIATION DAMPER INSTALLATION GUIDE" REQUIREMENTS IN ALL CASES. SMOKE AND RADIATION DAMPER INSTALLATION GUIDE" FOR OTHER CONFIGURATION REQUIREMENTS.COMPLY FOR OTHER CONFIGURATION REQUIREMENTS.COMPLY PRO PED FULLY WITH ABOVE MENTIONED AND ALSO AHJ FULLY WITH ABOVE MENTIONED AND ALSO AHJ �c,<`�AGI NEF sio 7 FIRE DAMPER 8 FIRE/SMOKE DAMPER REQUIREMENTS IN ALL CASES. 9 FIRE/SMOKE DAMPER REQUIREMENTS IN ALL CASES 5 9P 29 NO SCALE NO SCALE NO SCALE G 9 �Y 15 Ry tyN N S(P DISCHARGE EXPIRES: 06-30-2016 PROJECT TITLE: EXHAUST FAN. 04 SEALANT(TYP.). NOTE: SEE ARCHITECTURAL 3"x IRON TUBE WELDED TO FRAME. DRAWINGS FOR LEVELING CURB CONSTRUCTION. EXHAUST DUCT, H TYPE 1. UPBLAST TYPE 18 GAUGE GALVANIZED EXHAUST FAN. COUNTERFLASHING TO GREASE WATER PROTECT AIRSPACE. DRAIN. 1-1/2"x1-1/2"x1/8"ANGLE IRON FRAME.ALL WELDED 40" CONSTRUCTION. VENTILATED CURB BIRDSCREEN BROAN 437 Q SEE DETAIL A ROOF CAP N a/ FOR ENLARGED VIEW. AIR INLET/OUTLET. 1/4"x1/4"MESH. + NOTE: SLOPED ROOF.COORDINATE SIZE AND LOCATION OF ROOF COUNTERFLASHING. rr LEVELING CURB, PENETRATIONS WITH GENERAL CONTRACTOR.ALL ROOFING --1 CANT STRIP AND 3 AND CURB INSTALLATION WITH GENERAL CONTRACTOR. CURB. 22 GAUGE FLASHING BY OTHERS. \ BACK PAN _ LAG BOLTS. Q ROOF VENT. 1 ON EACH SIDE. BACKDRAFT DAMPER. O ROOF.--\ 1/2"BIRDSCREEN Li BIRD SCREEN LAG BOLTS v WELDED TO FRAME. 1 ON EACH SIDE). FLASHING. i T I A I 1 ( ) DUCT SIZE AS NOTED ON AS REQU RED ONEF BIRD SCREEN °3 > 6X6MM(1/4"x1/4") \ v Z 0.l I` il.i 1i I`i ` i` i i i �i ✓ i 1 2„ MESH. ROOFING. p Ca 3" � i 14"MIN. SIZE AS REQUIRED. COUNTER FLASHING. cJ z LAG BOLT. TYPICAL f O z 2x AS REQUIRED. a ONE PER SIDE. LEVELING CURB. W x ROOF DECK. FIRE RATED ENCLOSURE BY CONSTRUCT GREASE HOOD FLASHING. FLASHING. CANT STRIP. N GENERAL CONTRACTOR. EXHAUST DUCT OF 16 CANT STRIP. y LEVELING CURB. � GAUGE GALVANIZED STEEL ROOFING. DUCT SIZE AS 4"0 EXHAUST Ei F WITH CONTINUOUS WELDED FIRE RATED ENCLOSURE. NOTED ON PLAN. NOTE: DUCTS con O o FIRE WRAP. SEAMS AND JOINTS. TRANSITION TO VENT COORDINATE SIZE AND LOCATION OF ROOF PENETRATION WITH GENERAL CONTRACTOR. vN AIR SPACE SIZE AS REQUIRED. COORDINATE ALL ROOFING AND CURB INSTALLATION WITH GENERAL CONTRACTOR. MIN. 3 INCHES. F 10 GREASE HOOD ROOF EXHAUST FAN FIRE WRAP. gfjAIL A 11 OUTSIDE AIR AND VENT 12 ROOF EXHAUST FAN 13 ROOF VENT DETAIL SHEET TITLE: NO SCALE NO SCALE NO SCALE NO SCALE DETAILS-HVAC DRAWN BY: SHEET: GJM > 7 xx M4.1 z a a o x M Vl M LLQ l V r O M Do 41 to a) en O O o O <`rn cn a w EXHAUST CEILINGFAN SURROUND RADIATION OPENING DAMPER. / WITH 5/8" SHEETROCK. �w W PVC 1 CEILING EXHAUST FAN DETAIL CONNECT TTOPVCDRAPTOR. CONNECT TO PVC DRAIN NO SCALE PIPE FROM DRAIN PAN. TRAP PIPING TO BE SHUTOFF VALVE. PRESSURE TEST WITH 1/4"BRANCH EE 1/4"PIPE PLUG(TYP.2). ova BRONZE SAME SIZE AS PIPING THREADED (TYP.). CONNECTION AT UNIT. TEE. ROOFTOP AC UNIT. UNION. EXTERIOR NOTE: (n Nt WALL THREADED 5" CENTER OUTLET OVER COORDINATE ALL ROOF SWEAT BRONZE SPLASH PLATE. PENETRATIONS AND FLASHING ADAPTOR. PLUG. WITH ROOF MANUFACTURER TO EQUIP. NOTE: AND INSTALLER.SEE ROOFING O 10" PROVIDE CONDENSATE TRAP SPECIFICATIONS AND PRESSURE REGULATOR. MIN. (2)LAYERS ARCHITECTURAL AT EACH CONDENSATE DRAIN ARCHITECTURAL DETAILS. %"LAYTYPERS S GWB GRILLE TO MATCH OUTLET ON HVAC-UNIT. SOLDER LEAD COUNTER FLASHING EXTERIOR COLOR 6"MAX SPECSEAL PROVIDE GALVANIZED TO TAPERED THREADEDCOUPLING. FIRESTOP COLLAR STEEL SPACER BAR 16"x16",SLB,SHEET HP-1 41� LEAD HOT MOPPED ONTO STOCK IF REQUIRED. ROOF IF BUILT UP ROOF MINIMUM 4"OVERLAP. LEAD FLASHING HOT MOP CONDENSATE ANCHOR TO HVAC SYSTEM. IF SINGLE PLY FLASHING TO ROOF. 26 GAGE METAL + (2)LAYERS OVER FLOW EQUIPMENT STEEL ROOF SYSTEM,PROVIDE � let TYPE'X'GWB 4"0 EXHAUST DUCT L CONDENSATE SUPPORT CHANNEL. A FELT WALK PAD. EXHAUST COORDINATE IN FIELD AS ROOF. CHANNEL TO WHICH ROOF COVERING ROOFING. FAN SEAL PENETRATION AND PIPE IS TO BE INSTALLED. WITH FIRE CAULK CLAMP. PLUG TYPICAL. TRAP SEAL SHALL BE: R PVC/ABS 4"0 PIPE FLOOR LINE s oz3s I t N�e3-20 TON AC-UNITS= 4"MIN. Joh :ROOF 2540 TON AC-UNITS= 6"MIN. nr.9c�lic 3-2334 RIS DRANVlC DATA AND DESIGNS THEREON USED OR 2 CEILING EXHAUST FAN DETAIL 3 THRU THE WALL HEAT PUMP 4 CONDENSATE TRAP 5 GAS PIPE ROOF PENETRATION SHALL NBE IXPDCAJm. WMA Disaom TD OTHERS FOR PROCUREMENT CR OTHER PURPD--EXCEPT AS OTNERMg AUIfgRIIID BY DONTItACT, NO SCALE rmOUT PERM®ON OF NO SCALE NO SCALE JET NDUSTRES,INC. NO SCALE IMSILVenoxRD. SAMOR11M TB:M31"M FAX:(513) OACCW C226; CACCBXOIEI ALL REPRODUCTIONS SMALL BEAR THIS NOME. REFRIGERANT LINES TO MATCH CONDENSING SCH.40 PVC UNIT MD FLUE AND COMBUSTION AIR INTAKE UP TO ROOF SIZE PER PLAN. I SUPPLY DUCT C OUTSIDE AIR C DUCT TO COOLING COIL EXTERIOR 3/4"CONDENSATE RETURN TO APPROVED DRAIN DUCT 3/4"GAS LINE BURNER 2 LB.GAS UNION SECTION REGULATOR 1/2" CLIPS IC ELECT.DISCONNECT GAS MAINTAIN CLEARANCES .JAS SPECIFIED BY SHUT-OFF BLOWER MANUFACTURER. VALVE SECTION TESTPORT FLOOR LINE PLAN VIEW STRUCTURAL ROOFTOP UNIT FRAMING(I-JOISTS) DRIP LEG FILTER 16 GUAGE (4)#10 TEC SCREWS SEISMIC 1 e'UNISTRUT MOISTURE DETECTION. HOLD DOWN WET SWITCH#WS-1 CLIP CONDENSING REFRIGERANT LINES FACTORY CURB UNIT TO RESPECTIVE UNISTRUT 6 UP FLOW FURNACE SECTION (EXISTING) (4)#10 TEC SCREWS FURNACES ANGLE CLIPS RIGID CURB NO SCALE 3/8"LAG EACH INSULATION REVISIONS: CORNER (4)#10 TEC SCREWS 1%"UNISTRUT FRONT CORNERS SIMPSON SSP EACH TRUSS ® 1%"UNISTRUT ONLY.BOTH DIRECTIONS. XFLASHING. ROOF DECK (4)#10x3"SCREWS PRESSURE-TREATED 6" "0 THREADED TIMBER CUT TO `Lz: / ROD SLOPE OF ROOF. ROOFING. TRUSSES TRUSSES EQUIPMENT PAD ® CANT STRIP. S ECT I O N HOOD SEISMIC CLIP HOLD ��PEDPROFFss ROOF DECK. NOTE: �5 N P ioyv WITHS STRUCTURAL SEE DRAWINGS OOFCUR g DOWN DETAIL — CURBS EXISTING 9 CONDENSING UNIT AT EXTERIOR WALL 10 HOOD HANGER DETAIL 5 SIP WITH STRUCTURAL BEFORE DRAWINGS FOR ROOF CURB AND EXACT ROOFING DETAILS. NO SCALE ROUGH-IN. NO SCALE NO SCALE �)'15,2p�J��� 7 CONDENSING UNIT CURB FYLYNNS�P EXPIRES: 06-30-2016 NO SCALE PROJECT TITLE: BLOCKING. O [5/8"]EYE BOLT ATTACHED WITH V NUT AND WASHER BOTH SIDES. TF-A MCENTER ABOVE DOOR AIRCRAFT CABLE ATTACHMENT CAPABLE OF WITHSTANDING NOTE: [80 LBS OF FORCE]. SLOPED ROOF.COORDINATE SIZE AND LOCATION OF ROOF CONDENSING UNIT. 5/B" EYE BOLT MAINTAIN CLEARANCES PENETRATIONS WITH GENERAL CONTRACTOR.ALL ROOFING REVERSOMATIC ATTACHED WITH AS SPECIFIED BY AND CURB INSTALLATION WITH GENERAL CONTRACTOR. LT-300 NUT AND WASHER MANUFACTURER. BOTH SIDES. ROOF VENT. ---�_ %"GWB WRAP, civ INSULATED REFRIGERANT 5 SIDES. + PIPES. BIRD SCREEN —— — LAG BOLTS [1/8"]AIRCRAFT �� (1 ON EACH SIDE). vi rF-L CABLE.SEISMIC GALV OR ZINC-A-LUME 6X6MM(1/4"x1/4") (u `J LIGHT SWITCH GUY WIRE TYP. COVER. MESH. OF FOUR SIDES. 14"MIN. I TF-A SECURELY COUNTER FLASHING. 4"0 DRYER THERMOSTAT FASTEN TO UNIT Q w CURB. LEVELING CURB. 2x AS REQUIRED. EXHAUST DUCT. � Q] f ALUMINUM CANT STRIP. SILICONE PIPE COVER. FLASHING. y F� O SEAL. DRYER BOX 425. Q Z m DUCT SIZE AS EWH-A ROOFING. NOTED ON PLAN. U0 ftt Oin ROOFING AND 48" FLASHING. SIE AS REQUIRED.NSITION TO NT Z u z (2)LAYERS 3M d 00 a ROOF. 615+FIRE WRAP. r _aF MOTORIZED DAMPER. 3 16" 12„ lik M y MAX. ��ROUTE REFRIGERATION PIPES o cn CURB(HEIGHT AS REQUIRED) TO FAN/COIL UNIT. FLOOR C`14o SEE STRUCTURAL FOR METAL STUDS. ELEVATOR SHAFT ATTACHMENT TO ROOF. 18 GA.SHEETMETAL CAP. FILL CAVITY WITH SPRAY FOAM INSULATION AIRTIGHT. SHEET TITLE: N° 13 ELEVATOR RELIEF VENT 14 DRYER VENT DETAIL 11 UNIT ELEVATION 12 ROOFTOP CONDENSING UNIT CURB PLATFORM ECOORDINATEDWITOH ARCHITECT. NO SCALE NO SCALE DETAILS-HVAC NO SCALE DRANK Br. SHEET: GJM O 0 PROJECT uj Lax. �. M4.2 F DATE T�iJ Z x a .a a �M M b �� O EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE = 2 00 SYMBOL DESCRIPTION ELECTRICAL SYMBOL DESCRIPTION ELECTRICAL SYMBOL DESCRIPTION ELECTRICAL v MUA-1 MODULAR MAKEUP AIR UNIT: GAS HEAT,EVAP COOLING 208 V/3 PH DS-1a DUCTLESS SPLIT SYSTEM OUTDOOR UNIT: 208 V/1 PH EF-10,EF-22 EXHAUST FAN: 115V/1 PH m 3,240 CFM AT 1.572 IN.E.S.P. 15.0 FLA;5 HP COOLING: 22.0 MBH TOTAL,14.1 MBH SENSIBLE;18 SEER MINIMUM. 12.0 FLA 300 CFM ATA IN.E.S.P. 1.1 FLA EVAPORATIVE COOLING: 9OF DB/68F WB EAT. 73F DB/68F WB LAT. 18.8 MCA HEATING:25.4 MBH AT 47 DEGREES,2.52 COP,8.5 HSPF MINIMUM. 15.5 MCA SONES: 5.1 MAXIMUM. DIRECT FIRED GAS HEATING:210.0 MBH INPUT;192.0 MBH OUTPUT;91.7%THERMAL EFFICIENCY. 30 MOCP MAXIMUM REFRIGERANT LINE LENGTH 98 FT. 20 MOCP PROVIDE CEILING RADIATION FIRE DAMPER AND ALUMINIUM GRILLE. EVAP SECTION:INTAKE HOOD,MESH FILTERS,MOTORIZED BACKDRAFT DAMPER,3-WAY APPROXIMATE OPERATING WEIGHT:125 LBS. APPROXIMATE OPERATING WEIGHT: 25 LBS. J SOLENOID VALVE,FREEZE PROTECTION FOR EVAP COOLING. BASIS OF DESIGN: DAIKIN RXN24KEVJU. BASIS OF DESIGN: REVERSOMATIC CF-425-FF. CONTROL:CONTINUOUS F APPROXIMATE OPERATING WEIGHT: 1,066 LBS. z BASIS OF DESIGN: CAPTIVE ARE UNIT A2-D.250-G15 DS-1b DUCTLESS SPLIT SYSTEM INDOOR UNIT: CONNECT TO EXTERIOR UNIT EF-14,EF-16,EF-18 EXHAUST FAN: 115 V/1 PH r ea tY COOLING: 22.0 MBH TOTAL,14.1 MBH SENSIBLE;18 SEER MINIMUM. EF-20,EF-21,EF-24 75 CFM AT.25IN.E.S.P. 0.2 FLA �w1 C RTU-1 PACKAGED ROOFTOP GASPACK AIR CONDITIONER: 208 V/3 PH HEATING:25.4 MBH AT 47 DEGREES,2.52 COP,8.5 HSPF MINIMUM. EF-29,EF-32,EF-37 SONES:0.3 MAXIMUM. CL 10 NOMINAL TONS 3,800 CFM AT.8 IN.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 56.0 FLA y PROVIDE WITH CONDENSATE PUMP. PROVIDE CEILING RADIATION FIRE DAMPER AND ALUMINIUM GRILLE. W o COOLING: 120.0 MBH TOTAL;96.0 MBH SENSIBLE;2-STAGE;11.1 EER MINIMUM. 53.1 MCA APPROXIMATE OPERATING WEIGHT: 50 LBS. APPROXIMATE OPERATING WEIGHT: 25 LBS. �y Y Q HEATING: 180.0 MBH INPUT;148.0 MBH OUTPUT; 80%THERMAL EFFICIENCY. 60 MOCP [- BASIS OF DESIGN: DAIKIN FTXN24KVJU. BASIS OF DESIGN: REVERSOMATIC QCF-80-ES-FF. CONTROL:CONTINUOUS O PROVIDE WITH ECONOMIZER;TWO SPEED INDOOR FAN MOTOR,RETURN AIR SMOKE DETECTOR d zV)Q APPROXIMATE OPERATING WEIGHT: 1,100 LBS. y DS-2a,DS-3a DUCTLESS SPLIT SYSTEM OUTDOOR UNIT: 208 V/1 PH EF-35,EF-42 EXHAUSTFAN 115 V/1 PH X W • BASIS OF DESIGN: CARRIER 48TCED12A2A5-0BOA. w COOLING: 12.0 MBH TOTAL; 18 SEER MINIMUM. 6.1 FLA 85 CFM AT.25 IN.E.S.P. 14.0 FLA Q U HEATING: 13.5 MBH AT 47 DEGREES,2.9 COP,8.5 HSPF MINIMUM. 7.0 MCA SONES:2.0 MAXIMUM. 20 MOCP U' RTU-2 PACKAGED ROOFTOP GASPACK AIR CONDITIONER: 208 V/3 PH 0 MAXIMUM REFRIGERANT LINE LENGTH 66 FT. 15 MOCP PROVIDE WITH HEATER,LIGHT AND i/62W SWITCH ACCESSORY,27 WATT CFL. CONTROL: WALL SWITCH-LIGHT. CL 0 7-1/2 NOMINAL TONS 2,850 CFM AT.8 IN.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 49 FLA APPROXIMATE OPERATING WEIGHT:100 LBS. APPROXIMATE OPERATING WEIGHT: 25 LBS. CONTROL: WALL SWITCH-FAN. O LL COOLING: 90.0 MBH TOTAL;72.0 MBH SENSIBLE;2-STAGE;11.0 EER MINIMUM. 46.0 MCA BASIS OF DESIGN: DAIKIN RXNI2KEVJU. BASIS OF DESIGN: BROAN I00HFL. CONTROL: TIMER-HEATER. O HEATING: 125.0 MBH INPUT;103.0 MBH OUTPUT; 80%THERMAL EFFICIENCY. 50 MOCP PROVIDE WITH ECONOMIZER AND CO2 SENSING; POWER EXHAUST. DS-2b,DS-3b DUCTLESS SPLIT SYSTEM INDOOR UNIT: CONNECT TO EXTERIOR UNIT EF-A EXHAUST FAN: 115 V/1 PH O W APPROXIMATE OPERATING WEIGHT:950 LBS. COOLING: 12.0 MBH TOTAL; 18 SEER MINIMUM. 85 CFM AT.25 IN.E.S.P. 14.0 FLA O BASIS OF DESIGN: CARRIER 48TCED08A2A5. HEATING: 13.5 MBH AT 47 DEGREES,2.9 COP,8.5 HSPF MINIMUM. SONES:2.0 MAXIMUM. 20 MOCP Q PROVIDE WITH CONDENSATE PUMP. PROVIDE WITH HEATER,LIGHT AND#62W SWITCH ACCESSORY,27 WATT CFL. CONTROL: WALL SWITCH-LIGHT. pq C- RTU-3 PACKAGED ROOFTOP GASPACK AIR CONDITIONER: 208 V/3 PH APPROXIMATE OPERATING WEIGHT: 25 LBS. APPROXIMATE OPERATING WEIGHT: 25 LBS. CONTROL: WALL SWITCH-FAN. 10 NOMINAL TONS 3,225 CFM AT.8 IN.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 56.0 FLA BASIS OF DESIGN: DAIKIN FTXNI2KEVJU. BASIS OF DESIGN: BROAN 100HFL. CONTROL: TIMER-HEATER. COOLING: 120.0 MBH TOTAL;96.0 MBH SENSIBLE;2-STAGE;11.1 EER MINIMUM. 53.1 MCA HEATING: 180.0 MBH INPUT;148.0 MBH OUTPUT; 80%THERMAL EFFICIENCY. 60 MOCP PTHP-A PACKAGE TERMINAL HEAT PUMP: 208 V/1 PH EF-B EXHAUST FAN: 115 V/1 PH PROVIDE WITH ECONOMIZER;TWO SPEED INDOOR FAN MOTOR,RETURN AIR SMOKE DETECTOR 370 CFM AT HIGH SPEED. 11.6 FLA 35 CFM AT.375 IN.E.S.P. .5 FLA Jet.{. APPROXIMATE OPERATING WEIGHT: 1,100 LBS. COOLING: 14.6 MBH TOTAL; 11.7 SENSIBLE; 11.2 EER MINIMUM 14.0 MCA SONES:2.5. BASIS OF DESIGN: CARRIER 48TCED12A2A5-0BOA. HEATING: 13.0 MBH AT 47 DEG; 3.3 COP MINIMUM;2.5 KW ELECTRIC HEAT. 15 MOCP PROVIDE CEILING RADIATION FIRE DAMPER. V) PROVIDE WITH POWER CORD;ARCHITECTURAL GRILLE. APPROXIMATE OPERATING WEIGHT: 25 LBS. a F-1,F-2,F4 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH SET OUTSIDE AIR DOOR TO PARTIAL OPEN=45 CFM. SHIP WITH FAN ON LOW SPEED. BASIS OF DESIGN: REVERSOMATIC EB-50FF. CONTROL: CONTINUOUS. Job\'umber: Contact: F-5,F-7, 1,500 CFM AT.71N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 9.0 FLA F APPROXIMATE OPERATING WEIGHT: 175 LBS. 14-0239I ill COOLING:48.0 MBH TOTAL;39.0 MBH SENSIBLE;13 SEER MINIMUM. 12.1 MCA Q BASIS OF DESIGN: GE ZONELINE AZ61H15DAB. TF-A TRANSFER FAN: 115 V/1 PH Design By: Telephonc: W smoualis (503)363-2334 HEATING: 80.0 MBH INPUT;75 MBH OUTPUT; 91.1%AFUE. 20 MOCP = 145 CFM MAXIMUM. .4 FLA J THIS DRAVANG DATA AND DESGNS THEREON PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC ROOF VENT. Q PTHP-B PACKAGE TERMINAL HEAT PUMP: 208 V/1 PH SONES:2.6 MAXIMUM SHALL NOT BE DIIPUCATED,USED OR DISCLOSED TO OTHERS FOR PROCUREMENT APPROXIMATE OPERATING WEIGHT: 160 LBS. 370 CFM AT HIGH SPEED. 11.6 FLA APPROXIMATE OPERATING WEIGHT: 15 LBS. OR OTHER PURPOSE.EXCEPT AS OTHERNISE AUTHOWED BY CONTRACT, BASIS OF DESIGN: CARRIER 59SC28080S21-20. a" COOLING: 7.0 MBH TOTAL; 5.6 SENSIBLE; 13.2 EER MINIMUM. 14.0 MCA BASIS OF DESIGN: REVERSOMATIC HT145. CONTROL: MTHOUT PERUISSICN OF BROAN 57W JET INDUSTRIES,INC. = HEATING: 8.2 MBH AT 47 DEG; 4.0 COP MINIMUM;2.5 KW ELECTRIC HEAT. 15 MOCP 1935SILWRT0110. SALEKOR 97191 TEL:(503)383.]31/ FAX:(SW)Y/-WOR CCB F-3,F-20,F-22 GAS FURNACE WITH DX COOLING COIL: 115 W 1 PH PROVIDE WITH POWER CORD;ARCHITECTURAL GRILLE. RVA,RV-2,RV-4 ROOF VENT: NONE 0225:CACC89475287 1,000 CFM AT.6 IN.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 52 FLA SET OUTSIDE AIR DOOR TO PARTIAL OPEN=45 CFM. SHIP WITH FAN ON LOW SPEED. RV-5,RV-6,RV-8 18"x 24"THROAT. AL REPRODUCTIONS O TI ENALL BEng THIS NORSE COOLING: 30.0 MBH TOTAL;22.4 MBH SENSIBLE;13 SEER MINIMUM. 7.5 MCA APPROXIMATE OPERATING WEIGHT: 125 LBS. RV-10,RV-11 BASIS OF DESIGN: GREENHECK WIH. HEATING:40.0 MBH INPUT;37.0 MBH OUTPUT; 92.1%AFUE. 15 MOCP BASIS OF DESIGN: GE ZONELINE AZ61HO9DAB. PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC VENT PER PLANS. RV-3,RV-7 ROOF VENT: 24 VOLT APPROXIMATE OPERATING WEIGHT: 121 LBS. EWH-1 THRU EWH-7 ELECTRIC WALL HEATER: 208 V/1 PH 18"x24"THROAT, MOTORIZED DAMPER. BASIS OF DESIGN: CARRIER 59SC26040S14-10. EWH-K1 70 CFM FAN. 2 KW BASIS OF DESIGN: GREENHECK WRH. CONTROL: FIRE ALARM HEATING: 6.8 MBH. 9.6 FLA F-6 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH SURFACE MOUNT,INTEGRAL THERMOSTAT. 20 MOCP RV-9,RV-12,RV-13 ROOF VENT: NONE 1,650 CFM AT.71N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 9.0 FLA APPROXIMATE OPERATING WEIGHT: 15 LBS. 44"x 44"THROAT. COOLING: 48.0 MBH TOTAL;39.0 MBH SENSIBLE;13 SEER MINIMUM. 12.1 MCA BASIS OF DESIGN: KING WHF2020. W BASIS OF DESIGN: GREENHECK WRH. HEATING: 80.0 MBH INPUT;75 MBH OUTPUT; 91.1%AFUE. 20 MOCP > 7 PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC ROOF VENT. EDHA,EDH-3 ELECTRIC DUCT HEATER: 208 V/1 PH 0 WL-1,WL-2,WL-3 WALL LOUVER: NONE APPROXIMATE OPERATING WEIGHT: 160 LBS. 100 CFM. .75 KW U3 36"X18",2.25 SQ FT NET FREE AREA. BASIS OF DESIGN: CARRIER 59SC2BO8OS21-20. HEATING: 2.4 MBH TOTAL. 3.6 FLA z BASIS OF DESIGN: RUSKIN ELF211D, W U) SIZE: 8"X8". 20 MOCP > UL F-8,F-9,F-19 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PHPROVIDE WITH AIR PROVING SWITCH,THERMAL OVERLOAD,MANUAL RESET. W p WL-3,WL-4 WALL LOUVER: NONE 1,900 CFM AT.61N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 9.0 FLA Q APPROXIMATE OPERATING WEIGHT: 25 LBS. 12"X12",0.5 SQ FT NET FREE AREA. COOLING: 60.0 MBH TOTAL;48.0 MBH SENSIBLE;13 SEER MINIMUM. 12.1 MCA 2 BASIS OF DESIGN:NAILOR DHRS HL2081STG1STA124. BASIS OF DESIGN: RUSKIN ELF211D. HEATING: 80.0 MBH INPUT;75.0 MBH OUTPUT; 91.1%AFUE. 20 MOCPIx U PROVIDE WITH SITE BUILT ECONOMIZER DAMPERS AND CONTROL. U EDH-2 ELECTRIC DUCT HEATER: 208 V/1 PH WL-5,WL-6 WALL LOUVER: NONE PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC ROOF VENT. Lu J 175 CFM. 1.0 KW 1 8"X12",0.7 SQ FT NET FREE AREA. APPROXIMATE OPERATING WEIGHT: 160 LBS. W HEATING:3.4 MBH. 4.8 FLA BASIS OF DESIGN: RUSKIN ELF211D. BASIS OF DESIGN: CARRIER 59SC2B080S21-20. SIZE: 8"X8". 20 MOCP W PROVIDE WITH AIR PROVING SWITCH,THERMAL OVERLOAD,MANUAL RESET. WL-7 WALL LOUVER: NONE ZF-10 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH APPROXIMATE OPERATING WEIGHT: 25 LBS. 36"X30-.2.7 SQ FT NET FREE AREA,MINIMUM. W" 750 CFM AT.61N,E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 5.2 FLA BASIS OF DESIGN:NAILOR DHRS HL2081STG1STA124. BASIS OF DESIGN: RUSKIN ELF211 D. LL COOLING:24.0 MBH TOTAL;19.2 MBH SENSIBLE;13 SEER MINIMUM. 7.5 MCA LuHEATING:40.0 MBH INPUT;37.0 MBH OUTPUT; 92.1%AFUE. 15 MOCP EWH-A ELECTRIC WALL HEATER: 208 V/1 PH H-1,H-2 HOOD FOR RESIDENTIAL EQUIPMENT: 115 W 1 PH LIGHT CIRCUIT LL PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC VENT PER PLANS. HEATING: 2.4 MBH TOTAL. .75 KW 36"W]DE X 30"DEEP X 10"TALL,DISCHARGE INTO FAN. CONNECT WITH EXHAUST FAN APPROXIMATE OPERATING WEIGHT: 121 LBS. RECESSED MOUNT,REMOTE THERMOSTAT. 3.6 FLA STAINLESS STEEL CONSTRUCTION. O BASIS OF DESIGN: CARRIER 59SC2B04OS14-10. APPROXIMATE OPERATING WEIGHT: 15 LBS. 20 MOCP BASIS OF DESIGN: CAPTIVEAIRE VHS. F-11,F-12,F-17 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH BASIS OF DESIGN: KING PZ2007. REVISIONS: 0 H-K1 TYPE I HOOD: 115 V/1 PH LIGHT CIRCUIT F-18,F-21,F-23 1,150 CFM AT.51N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 7.6 FLA EF-K1 EXHAUST FAN: 208 V/3 PH p PROVIDED BY KITCHEN SUPPLIER,INSTALED BY HVAC CONTRACTOR. 115 V/1 PH ANSUL CIRCUIT COOLING: 36.0 MBH TOTAL;33.0 MBH SENSIBLE;13 SEER MINIMUM. 10.4 MCA 3,750 CFM AT 1.5 IN.E.S.P. 9.5 FLA = BASIS OF DESIGN: CAPTIVEAIRE ND5424 ND2PSP-F. HEATING: 60.0 MBH INPUT;56.0 MBH OUTPUT; 92.1%AFUE. 15 MOCP SONES:21 MAXIMIM. 20 MOCP PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC VENT. RATED FOR GREASE; PROVIDE WITH HINGE KIT. VFD RATED MOTOR H-K2 TYPE II VAPOR HOOD: 115 V/1 PH LIGHT CIRCUIT APPROXIMATE OPERATING WEIGHT: 142 LBS. APPROXIMATE OPERATING WEIGHT: 325 LBS. PROVIDED BY KITCHEN SUPPLIER,INSTALED BY HVAC CONTRACTOR. BASIS OF DESIGN: CARRIER 59SC2606OS17-16. BASIS OF DESIGN: CAPTIVE AIR NCA2HPFA. CONTROL:AT HOOD. BASIS OF DESIGN: CAPTIVEAIRE VHS F-13,F-14 GAS FURNACE WITH DX COOLING COIL: 115V/1 PH EF-K2 EXHAUST FAN: 115V/1 PH 1,750 CFM AT.71N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 9.0 FLA 525 CFM AT.75 IN,E.S.P. 4.1 FLA, 5.2 MCA COOLING:48.0 MBH TOTAL;39.0 MBH SENSIBLE;13 SEER MINIMUM. 12.1 MCA SONES: 9.4 MAXIMUM. 15 MOCP Ep PROF HEATING: 80.0 MBH INPUT;75 MBH OUTPUT; 91.1%AFUE. 20 MOCP APPROXIMATE OPERATING WEIGHT: 100LBS. CONTROL: CURRENTSWITCH �g'���r,INEEssio PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC ROOF VENT. BASIS OF DESIGN: CAPTIVE AIR DU33HFA. ON DISHWASHER CIRCUIT. APPROXIMATE OPERATING WEIGHT: 160 LBS. Q 5 9P BASIS OF DESIGN: CARRIER 59SC213080S21-20. EF-K3,EF-K4 EXHAUST FAN: 115V/1 PH 50 CFM AT.375 IN.E.S.P. 1.0 FLA G F-15 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH SONES:2.5. (,15,5 1,600 CFM AT.71N.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 9.0 FLA APPROXIMATE OPERATING WEIGHT: 15 LBS. CONTROL: FytYN N S'(P COOLING: 48.0 MBH TOTAL;39.0 MBH SENSIBLE;13 SEER MINIMUM. 12.1 MCA BASIS OF DESIGN: REVERSOMATIC EB-00 CONTINUOUS HEATING: 80.0 MBH INPUT;75 MBH OUTPUT; 91.1%AFUE. 20 MOCP EXPIRES: 06-30-2016 PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC ROOF VENT. EF-1,EF-7,EF-8 EXHAUST FAN: 115V/1 PH PROJECT TITLE: APPROXIMATE OPERATING WEIGHT: 160 LBS. EF-11 100 CFM AT.375 IN.E.S.P. .3 FLA BASIS OF DESIGN: CARRIER 59SC2BO8OS21-20. SONES:2.0 MAXIMUM. PROVIDE CEILING RADIATION FIRE DAMPER AND ALUMINIUM GRILLE. O F-16 GAS FURNACE WITH DX COOLING COIL: 115 V/1 PH APPROXIMATE OPERATING WEIGHT:25 LBS. 1,150 CFM AT.5 IN.E.S.P.;SEE VENTILATION SCHEDULE FOR OSA REQUIREMENTS. 7.6 FLA BASIS OF DESIGN: REVERSOMATIC QCF-125ES-FF. CONTROL:CONTINUOUS COOLING: 36.0 MBH TOTAL;33.0 MBH SENSIBLE;13 SEER MINIMUM. 10.4 MCA HEATING: 60.0 MBH INPUT;56.0 MBH OUTPUT; 92.1%AFUE. 15 MOCP EF-2,EF-13,EF-15,EF-17 EXHAUST FAN: 115 V/1 PH PROVIDE WITH CONDENSATE NEUTRALIZER KIT AND CONCENTRIC VENT. EF-25,EF-26,EF-27,EF-28 50 CFM AT.375 IN.E.S.P. 1.0 FLA APPROXIMATE OPERATING WEIGHT: 142 LBS. EF-30,EF-31,EF-33,EF-34 SONES:2.5. BASIS OF DESIGN: CARRIER 59SC26060S17-16. EF-35,EF-36,EF-38,EF-39 WITH CEILING RADIATION DAMPER APPROXIMATE OPERATING WEIGHT: 15 LBS. CU-1,CU-2,CU-4 OUTDOOR CONDENSING UNIT: 208 V/1 PH BASIS OF DESIGN: REVERSOMATIC EB-60-FF. CONTROL:CONTINUOUS CU-5,CU6,CU-7 COOLING:48.0 MBH TOTAL;13.0 SEER MINIMUM. 21.1 FLA CU-13,CU-14,CU-15 APPROXIMATE OPERATING WEIGHT: 236 LBS. 26.2 MCA EF-3,EF-4,EF-12 EXHAUST FAN: 115 V/1 PH U 4 NOM TONS BASIS OF DESIGN: CARRIER 24ACB348-30. 40 MOCP EF-13 100 CFM AT.375 IN.E.S.P. .3 FLA SONES:2.0 MAXIMUM. + CU-3,CU-20,CU-22 OUTDOOR CONDENSING UNIT: 208 V/1 PH PROVIDE ALUMINIUM GRILLE. F 2.5 NOM TONS COOLING: 30.0 MBH TOTAL;13.0 SEER MINIMUM. 13.6 FLA APPROXIMATE OPERATING WEIGHT:25 LBS. Y x Z APPROXIMATE OPERATING WEIGHT: 149 LBS. 17.6 MCA BASIS OF DESIGN: REVERSOMATIC QCF-125ES. CONTROL:CONTINUOUS I--I O BASIS OF DESIGN: CARRIER 24AC833030. 25 MOCP I z EF-5 EXHAUST FAN: 115V/1 PH Q O z CU-8,CU-9,CU-19 OUTDOOR CONDENSING UNIT: 208 V/1 PH 200 CFM AT.375 IN.E.S.P. 1.26 FLA W Z 5 NOM TONS COOLING: 60.0 MBH TOTAL;13.0 SEER MINIMUM. 27.6 FLA SONES:4.0 MAXIMUM. z O APPROXIMATE OPERATING WEIGHT: 261 LBS. 34.2 MCA PROVIDE ALUMINIUM GRILLE. w F�+I II,--.--J�� Q PEIp BASIS OF DESIGN: CARRIER 24ACB36031. 50 MOCP APPROXIMATE OPERATING WEIGHT: 25 LBS. ABASIS OF DESIGN: REVERSOMATIC QCF 300ES. CONTROL:CONTINUOUS U 0 CU-10 OUTDOOR CONDENSING UNIT: 208 V/1 PH per"., 2 NOM TONS COOLING: 24.0 MBH TOTAL;13.0 SEER MINIMUM. 14.3 FLA Z EF6,EF-40 EXHAUST FAN: 115 V/1 PH Q APPROXIMATE OPERATING WEIGHT: 135 LBS. 17.6 MCA < 300 CFM ATA IN.E.S.P. 1.1 FLAILL BASIS OF DESIGN: CARRIER 24ACB324-30. 25 MOCP F SONES: 5.1 MAXIMUM. W �j CIO PROVIDE CEILING RADIATION FIRE DAMPER AND ALUMINIUM GRILLE. CU-11,CU-12,CU-17 OUTDOOR CONDENSING UNIT: 208 V/1 PH = APPROXIMATE OPERATING WEIGHT:25 LBS. CONTROL: WITH RANGE. N W O O CU-16,CU-18,CU-21 COOLING: 36.0 MBH TOTAL;13.0 SEER MINIMUM. 15.5 FLA W BASIS OF DESIGN: REVERSOMATIC CF-425 CURRENT SENSOR. CU-23 APPROXIMATE OPERATING WEIGHT: 166 LBS. 19.0 MCA 3 NOM TONS BASIS OF DESIGN: CARRIER 24ACB336.30. 30 MOCP EF-9 EXHAUST FAN: 115 V/1 PH SHEET TITLE: 50 CFM AT 0.10 IN.E.S.P. 46 WATTS SCHEDULES-HVAC SONES:3.0 MAX APPROXIMATE OPERATING WEIGHT: 5 LBS. BASIS OF DESIGN:GREENHECK:SP-050 CONTROL:SWITCH DR WN BY: SHEET: C] W H M5.1 < 7 D IE: a ,-a LL Y �M b �O 00 COM D0 CO C 2,=M 0 cl CHAPTER 4 VENTILATION SCHEDULE CHAPTER 4 VENTILATION SCHEDULE Un° E OCCUPANCY AREA LOAD OSA PER OCCUPANT MECHANICAL ROOM OSA% OSA OSA ZONE SYSTEM POPULATION OSA PER EXHAUST OCCUPANT MECHANICAL ROOM OSA% OSA OSA ZONE SYSTEM POPULATION OCCUPANCY AREA LOAD OSA PER OSA PER EXHAUST ROOM NAME CLASSIFICATION SO FT PER 1000 PERSON SO FT PER SO FT LOAD UNIT# CFM CFM PROVIDED REQUIRED EFFECT EFFICENCY EXHAUST D UNIT# CFM CFM PROVIDED REQUIRED EFFECT EFFICENCY DIVERSITY NOTES DIVERSITY NOTES ROOM NAME CLASSIFICATION SO FT PER 1000 PERSON SO FT GARDEN RM 1007 PREFUNCTION 445 30 7.5 0.06 0 13.4 F-1 750 20.0% 150 159 0.8 MAIL 1006 CORRIDOR 140 0 0 0.06 0 0.0 F-1 100 20.0% 20 11 0.8 �w PREFUNCTION 480 30 7.5 0.06 0 14.4 F-1 650 20.0% 130 171 0.8 GARDEN RM./WORKSHOP 1007 PREFUNCTION 500 30 7.5 0.06 0 15.0 EF-1 100 100.0% 100 14 PARLOR 1004 S 1065 27.8 F-1 1500 20.0% 300 268 0.95 0.75 MECH/JANITOR 1029 STORAGE 65 0 0 0.06 0 0.0 EF-2 75 100.0% 75 4 ww CAFE 1033 PREFUNCTION 1020 30 7.5 0.12 0 30.6 F-2 1500 16.7% 250 440 0.8 MEN 1030 TOILET 90 0 0 0.06 0 0.0 EF-3 100 100.0% 100 5 oM TOILET 90 0 0 0.06 0 0.0 EF-4 100 100.0% 100 5 1020 30.6 F-2 1500 16.7% 250 224 0.98 0.50 WOMEN 1031 O OFFICE 1012 OFFICE 170 5 5 0.06 0 0.9 F-3 150 20.0% 30 18 0.8 WORK 1017 OFFICE 180 5 5 0.06 0 0.9 EF-5 100 100.0% 100 15 PRIVATE DINING 1011 ACTIVITY KITCHEN 20041 H-1 PREFUNCTION 155 0 0 0 0.7 0.0 EF-6 300 100.0% 300 0 d DINING 200 70 7.5 0.18 0 14.0 F-3 250 20.0% 50 176 0.8 RECEPTION 1014 OFFICE 100 30 5 0.06 0 3.0 F-3 150 20.0% 30 26 0.8 ARTS/CRAFTS 2002 PREFUNCTION 1250 30 7.5 0.06 0 37.5 EF-7 100 100.0% 100 356 d Q OFFICE 1016 OFFICE 110 5 5 0.06 0 0.6 F-3 100 20.0% 20 12 0.8 •M OFFICE 1013 OFFICE 140 5 5 0.06 0 0.7 F-3 125 20.0% 25 15 0.8 FITNESS 1029 HEALTHANEIGHTS 767 10 20 0.06 0 7.7 EF-8 100 100.0% 100 199 WORK 1017 OFFICE 90 5 5 0.06 0 0.5 F-3 125 20.0% 25 10 0.8 SALON 440 0 0 0 0 0.0 EF-9 50 100.0% 50 50 9 �w 264 RCC 1018 OFFICE 100 5 5 0.06 0 0.5 F-3 100 20.0% 20 11 0.8 SALON 2016 �J 910 20.1 F-3 1000 20.0% 200 141 0.95 0.50 SALON 2016 SALON 440 0 0 0 0.6 0.0 EF-10 300 100.0% 300 WOMEN 2013 TOILET 110 0 0 0 0 0.0 EF-11 100 100.0% 100 0 ACTIVITY KITCHEN 2004 KITCHEN 170 0 0 0 0.7 0.0 F-4 125 20.0% 25 0 0.8 MEN 20 TOILET 110 0 0 0 0 0.0 EF-12 100 100.0% 100 0 O ACT/CRAFTS 2002 PREFUNCTION 950 30 7.5 0.06 0 28.5 F4 1375 20.0% 275 338 0.8 1120 28.5 1 F4 1500 20.0% 300 267 0.95 0.75 STORAGE STORAGE 0 0 0.06 0 0.0 1 EF-13 50 100.0% 50 0 FITNESS 2015 HEALTHMEIGHTS 760 10 20 0.06 0 1. F-5 1000 21.7% 217 241 0.8 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-14 75 100.0% 75 0 SALON 2016 BEAUTY 440 25 20 0.12 0.5 11.0 F-5 500 21.7% 108 341 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-15 50 100.0% 50 1200 18.6 F-5 1500 21.7% 325 315 0.93 0.50 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-16 75 100.0% 75 et CORR2001 CORRIDOR 1370 0 0 0.06 0 0.0 F-6 750 16.7% 125 103 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-17 50 100.0% 50 0 T 1370 0.0 F-6 750 16.7% 125 104 0.98 1.00 J��__ LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-18 75 100.0% 75 0 HOSPITALITY 2007 PREFUNCTION 1900 30 7.5 0.06 0 57.0 F-8 1750 18.4% 322 677 0.8 SHOWER 0 0 0.06 0 0.0 EF-19 85 100.0% 85 0 MEN 2012 TOLIET ROOM 120 0 0 0 50/70 0.0 F-8 75 18.4% 14 0 0.8 BATHER ENGINEERING 0 50/70 0.0 F-8 75 18.4% 14 0 0.8 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-20 75 100.0% 75 JuL\u.nber: Contasr. 14-0239 J. WOMEN 2013 TOLIET ROOM 120 0 0 ff Stauffer 57.0 F-8 1900 18.4% 350 350 0.97 0.50 CHARTS OFFICE 5 5 0.6 0 0.0 EF-21 75 100.0% 75 O JLS By: (503)3 3-2 1900 JLS (503)363-2334 SOILED LAUNDRY 20 7.5 0.06 0 0.0 EF-22 300 100.0% 300 O THIS DRA4AI-L N D DATA ANDTED,DESIGNS D THEREON THEATER 2009 PREFUNCTION 860 30 5 0.06 0 26.4 F-7 1500 13.3% 200 231 0.8 xOLL NOT BE PURPOSE. EXCEPT PT A DR SHOWER 0 0 0.06 0 0.0 EF-23 85 100.0% 85 0 DISCLOSED To OTHERS FOR PROCUREMENT SHOWER OR OTHER AUTHORIZED ExcCON RA 26.4 F-7 1500 13.3% 200 116 1.00 0.50 omERvnsE autHorazm ar coxTRacr, STAFF CONFERENCE 50 5 0.06 0 0.0 EF-24 75 100.0% 75 0 MTHOur PERMISSION OF LOBBY 1002 MAIN ENTRANCE LOBBY 1260 30 5 0.06 0 37.8 F-9 1900 10.5% 200 331 0.8 0 0.0 EF-25 50 100.0% 50 0 1.00 0.50 TOILET TOILET 0 0 0 1260 37.8 F-9 1900 10.5% ZOO 165 ALL REPRaoucna+s SHALL BEAR STORAGE STORAGE D 0 0.06 0 0.0 EF-26 75 100.0% 75 0 THIS xoncE. CORR3001 CORRIDOR 1520 0 0 0.06 0 0.0 F-10 750 16.7% 125 114 0.8 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-27 75 100.0% 75 50 0.0 F-10 750 16.7% 125 116 0.98 1.00 TOILET TOILET 0 0 0 0 0.0 EF-28 50 100.0% 50 0 CORR 1040,1042,1046 CORRIDOR 2200 0 0 0.06 0 0.0 F-11 1150 17.4% 200 165 0.8 WORK PRINTING 4 5 0.06 0 0.0 EF-29 75 100.0% 75 0 0.0 F-11 1150 17.4% 200 169 0.98 1.00 CORRIDOR 1050 CORRIDOR 1500 0 . 0.06 0 0.0 F-12 825 23.9% 1 113 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-30 50 100.0% 50 0 LAUNDRY 2047 LAUNDRY 510 20 7.5 0.06 0 10.2 F-12 325 23.9% 788 134 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-31 50 100.0% 50 0 2010 10.2 F-12 1150 23.9% 275 270 0.91 1.00 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-32 75 100.0% 75 0 CORRIDOR 2050,2040,2042 CORRIDOR 2360 0 0 0.06 0 0.0 F-13 1625 14.3% 232 177 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-33 50 100.0% 50 0 LAUNDRY 2047 LAUNDRY 200 20 7.5 0.06 0 4.0 F-13 125 14.3% 18 53 0.8 STORAGE 0 0 0.06 0 0.0 EF-34 50 100.0% 50 0 STORAGE 2560 4.0 F-13 1750 14.3% 250 230 1.00 1.000.0 EF-35 50 100.0% 50 0 STORAGE STORAGE 0 0 0.06 0 CORRIDOR 3050,3042,3040 CORRIDOR 2360 0 0 0.06 0 0.0 F-14 1625 14.3% 232 177 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-36 50 100.0% 50 0 LAUNDRY 2047 LAUNDRY 200 20 7.5 0.06 0 4.0 F-14 125 14.3% 1B 53 0.8 1.00 1.00 LAUNDRY LAUNDRY 20 7.5 0.06 0 0.0 EF-37 75 100.0% 75 50 2560 4.0 F-14 1750 14.3% 250 230 OFFICE 175 20 7.5 0.06 0 3.5 F-15 125 18.8% 23 46 0.8 STORAGE STORAGE 0 0 0.06 0 0.0 EF-38 50 100.0% 50 0 ALF CHARTS 1063 STORAGE 0 0 0.06 0 0.0 EF-39 50 100.0% 50 0 SOILDED LINEN 1067 LAUNDRY 250 20 7.5 0.06 0 5.0 F-15 200 18.8% 38 66 0.8 STORAGE CLEAN LINEN 1066 LAUNDRY 120 20 7.5 0.06 0 2.4 F-15 75 18.8% 14 32 0.8 KITCHEN 150 0 0 0-06 0 0.0 EF-40 300 100.0% 300 9 CLEAN LINEN 1062 LAUNDRY 85 5 5 0.06 0 0.4 F-15 75 18 8% 14 9 0 8 SERVING KITCHEN 1095 MED ROOM 1065 OFFICE 105 5 5 0.06 0 0.5 F-15 75 18.8% 14 11 0.8 SCHEDULE NOTES: CORRIDOR 1060,1092 CORRIDOR 1600 0 0 0.06 0 0.0 F-15 1050 18.8% 197 120 0.8 a. ROOM PROVIDED WITH DEMAND CONTROLLED VENTILATION. 2335 11.9 F-15 1600 18.8% 300 221 0.96 0.75 b. ESTIMATED OCCUPANT LOAD. 0 0.06 0 0.0 F-16 1150 20.0% 230 113 0.8 c. TYPE 1 HOOD HAS 3,750 CFM EXHAUST. CORRIDOR 1071,1091 CORRIDOR 1500 0 32 0.8 d. 50 CFM PER FIXTURE. CONTINUOUS EXHAUST. STAFF 1070 PREFUNCTION 120 30 5 0.06 0 3.6 F-16 100 20.0% 20 3.6 F-16 1250 20.0% 250 152 0.95 1.00 e. SEE EXHAUST SECTION. 1620 f.2 PERSONS AT 15 CFM FOR 1ST BEDROOM. TWO BEDROOM UNITS HAVE(2)PHTP FOR 90 CFM OSA. ACTIVITY 1079 PREFUNCTION 275 30 5 0.06 0 8.3 F-17 600 17.4% 104 72 0.8 g.MANICURE FAN AT NAIL STATION. REVISIONS: LINING ROOM 1078 PREFUNCTION 440 30 5 0.06 0 13.2 F-17 550 17.4% 96 116 0.8 715 21.5 F-17 1150 17.4% 200 144 0.98 0.75 CORRIDOR 1076 CORRIDOR 900 0 0 0.06 0 0.0 F-18 75 17.4% 87 68 0.8 DIFFUSER, REGISTER AND GRILLE SCHEDULE 0.5 F-16 7s 17.a% 13 10 0.6 FACE FRAME DAMPER FINISH BASIS OF DESIGN NOTES WKRM 1081 OFFICE 90 5 5 o.os o 17.4% 17 26 VEST 1084 PREFUNCTION 100 30 5 0.06 0 3.0 F-18 100 0.8 SYMBOL TYPE LOBBY 10PREFUNCTION 150 30 5 0.06 0 . 83 ERED LAY-IN NONE WHITE TITUS TDC 45 F-18 125 17.4% 22 39 0.8 CD-1 CEILING DIFFUSER LOUV MC MEDS 83 OFFICE 72 5 5 0.06 0 0.4 F-18 75 17.4% 13 8 0.8 CD-2 CEILING DIFFUSER LOUVERED SURFACE OBD WHITE TITUS TDC MC CHARTS 1089 OFFICE 120 5 5 0.06 0 0.6 F-18 100 17.4% 17 13 0.8 SG-1 SUPPLY GRILLE DOUBLE DEFL. 1-114"BORDER NONE WHITE TITUS 300RL;300RS 1 ADMIN 1082 OFFICE 150 5 5 0.06 0 0.8 F-18 175 17.4% 30 16 0.8 SR-1 SUPPLY REGISTER DOUBLE DEFL. 1-1/4"BORDER OBD WHITE TITUS 30ORL;30ORS 1 1582 0.0 F-18 1150 17.4% 200 138 0.98 0.75 CRG-1 CEILING RETURN GRILLE EGGCRATE LAY-IN NONE WHITE TITUS 50R Ep PROFc�s ��c� � GI N EF ip29 DINING 1094 DINING 810 70 7.5 0.18 0 56.7 F-19 1200 21.1% 253 714 0.8 CRG-2 CEILING RETURN GRILLE EGGCRATE SURFACE OBD WHITE TITUS SOR RG-1 RETURN GRILLE FIXED BAR 1-114"BORDER NONE WHITE TITUS 350RL;35OR 1 SERVING KITCHEN 1095 KITCHEN 182 0 0 0 0.7 0.0 F-19 300 21.1% 63 0 0.8 5 9P CORRIDOR 1091 CORRIDOR 320 0 0 0.06 0 0.0 F-19 400 21.1% 84 24 0.8 RR-1 RETURN REGISTER FIXED BAR 1-1/4"BORDER OBD WHITE TITUS 1312 56.7 F-19 1900 21.1% 400 393 0.94 0.50 CEG-1 CEILING EXHAUST GRILLEE EGGCRATE SURFLAY-IACE NONE WHITE TITUS 5OR G CEG-2 CEILING EXHAUST GRILLE EGGCRATE SURFACE NONE WHITE TITUS 50R CORRIDOR 2091 CORRIDOR 1080 0 0 0.06 0 0.0 F-20 775 15.0% 116 81 0.8 CER-2 CEILING EXHAUST REGISTER EGGCRATE SURFACE OBD WHITE TITUS 50R �,9 �Y 15, C Py LYN N SSP LAUNDRY 2067 LAUNDRY 250 20 7.5 0.06 0 5.0 F-20 225 15.0% 34 66 0.8 EG-1 EXHAUST GRILLE FIXED BAR 1-1/4"BORDER NONE WHITE TITUS 350RL;350 1 1330 5.0 F-20 1000 15.0% 15_0_______147 1.00 1.00 ER-1 EXHAUST REGISTER FIXED BAR 1-114"BORDER OBD WHITE TITUS 350RL;350RS EXPIRES: 06-30-2016 CTG-1 CEILING TRANSFER GRILLE EGGCRATE LAY-IN NONE WHITE TITUS 50R PROJECT TITLE: CORRIDOR 2060,2076,2069 CORRIDOR 1530 0 0 0.06 0 0.0 F-21 1150 13.0% 150 115 0.8 WHITE TITUS 50R 1.00 1.00 CTG-2 CEILING TRANSFER GRILLE EGGCRATE SURFACE OBD 1530 0.0 F-21 1150 13.0% 150 115 C' CTG-3 CEILING TRANSFER GRILLE FIXED BAR 1-114"BORDER NONE WHITE TITUS 350RL 2 LAUNDRY 3078 LAUNDRY 250 20 7.5 0.06 0 5.0 F-22 225 15.0% 34 66 0.8 DTG-1 DOOR TRANSFER GRILLE NON-VISION SURFACE NONE MATCH DOOR TITUS T700L CORRIDOR 3091 CORRIDOR 1110 0 0 0.06 0 0.0 F-22 775 15.0% 116 83 0.8 TG-1 TRANSFER GRILLE FIXED BAR 1-1/4"BORDER NONE WHITE TITUS 350RL;350RS 1 1360 5.0 F-22 1000 15.0% 150 149 1.00 1.00 NOTES: CORRIDOR 3060,3069,3076 CORRIDOR 1700 0 0 0.06 0 0.0 F-23 750 13.0% 98 128 0.8 1. FRONT BLADES TO RUN PARALLEL TO FLOOR. 1700 0.0 F-23 750 13.0% 98 128 1.00 1.00 2. INSTALL WITH INSECT SCREEN. IL DINING RM 1010 DINING ROOM 4030 70 7.5 0.18 0 282.1 RTU-1 3800 44.5% 1691 3551 0.8 282.1 RTU-1 3800 44.5% 1691 2519 0.71 0.50 AL DINING RM 1026 DINING ROOM 2580 70 7.5 0.18 0 180.6 RTU-2 2800 48.5% 1358 2274 0.8 U 180.6 RTU-2 2800 48.5% 1358 1709 0.67 0.50 + KITCHEN CORRIDOR KITCHEN 500 0 0 0.06 0 0.0 RTU-3 400 21.7% 87 38 0.8 U QI KITCHEN KITCHEN 1650 0 0 0 0.7 0.0 RTU-3 2550 21.7% 553 1155 0.8 STORAGE 280 0 0 0.06 0 0.0 RTU-3 200 21.7% 43 21 0.8 y ^ DRY STORAGE OFFICE 100 5 5 0.06 0 0.5 RTU-3 75 21.7% 16 11 0.8 OFFICE 2530 0.5 RTU-3 3225 21.7% 700 1312 0.93 1.00 Q RESIDENCE UNITS LIVING <1500 0 0 0 0 2.0 PTHP-A 375 12.0% 45 175 30 5 0.06 0 5.3 PTHP-1 375 12.0% 45 34 0.8 1.00 0.75 -N I.J� > a C/] p STAFF 1061 PREFUNCTION r Q d z DJ N z a z ''' Z UO N W 0 W � SHEET TITLE: SCHEDULES-HVAC DRAWN BY: SHEET: PROJECT k: M5.2 13- DATE. AX 7 O < rn F Z cn a .� a