Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (5)
FIRE ALARM LEGEND FIRE ALARM INDICATING APPLIANCE, AUDIBLE/VISUAL (HORN/STROBE), Ic�N 82db CODE 3 HORN @ 24VDC, WALL MOUNTED 80" AFF. FIRE ALARM INDICATING APPLIANCE, VISUAL (STROBE), cd RATING ON PLAN, WALL MOUNTED 80" AFF. dZK FIRE ALARM INDICATING APPLIANCE, VISUAL (EXP STROBE), EXP EXP=EXPLOSION PROOF, 150cd @ 24VDC, WALL MOUNTED 80" AFF. FIRE ALARM INDICATING APPLIANCE, AUDIBLE (HORN), EXP EXP=EXPLOSION PROOF, 100db CONTINOUS HORN @ 24VDC, WALL MOUNT. [FAC—PI FIRE ALARM PANEL FACP; FIRE ALARM CONTROL PANEL, FAAP; FIRE ALARM REMOTE ANNUNCIATOR PANEL, FAPS; FIRE ALARM BOOSTER POWER SUPPLY, FATC; FIRE ALARM TERMINAL CABINET. FADP; FIRE ALARM DIALER PANEL. ANALOG ADDRESSABLE SMOKE DETECTOR OP 'F" PHOTOELECTRIC, "I"=ION, "3D"=PHOTO, HEAT, "4D"=PHOTO, HEAT, ION O ANALOG ADDRESSABLE HEAT DETECTOR, R "R" RATE -OF -RISE, "F" 135 DEGREE FIXED. ANALOG ADDRESSABLE DUCT DETECTOR. "P" PHOTOELECTRIC. P SAMPLE PIPE MODELIWIDTH; ST -10/6"-1', ST -25/1'-3', ST -100/5-10' 't r l FIRE ALARM MANUAL PULL STATION, WALL MOUNTED 42" AFF, LION. FCRI CONTROL RELAY MODULE W/MONITOR POINT. FS SINGLE INPUT SIGNAL MODULE. © SINGLE INPUT MONITOR MODULE. DM DUAL INPUT MONITOR MODULE. ® RELAY MODULE, NON -ADDRESSABLE DS DUAL SYNC. MODULE 2„24K END OF LINE RESISTOR, 24K Ohm SHOWN. Sheet Size: 24"x36" = 1:1 Scale Zumiez reM VjWASHINGTON SQUARE WASHINGTON SQ. MALL -SUITE A04 9491 SW WASHINGTON SQ. ROAD TIGARD, OREGON GENERAL NOTES: THIS FIRE PROTECTION DESIGN IS BASED ON BUILDING CONFIGURATIONS AS OF THE DATE OF THE LATEST REVISION TO THIS DRAWING. 1. DETECTION DEVICES ADDRESSES ARE INDICATED WITH (6) DIGIT NUMBERS. 2. MINIMUM WIRE SIZE SHALL BE 16 AWG UNLESS OTHERWISE NOTED. 3. ALL WIRE TO INDICATING DEVICES IS ELECTRICALLY SUPERVISED. PARALLEL BRANCHING OF WIRE IS NOT PERMISSIBLE. 4. ALL WIRE SHALL CONFORM TO NEC LATEST EDITION. 5. SMOKE DETECTORS SHALL NOT BE MOUNTED INDIRECT AIRSTREAM OF SUPPLY AIR DUCTS. 6. WIRE DESIGNATIONS: TSP = TWISTED SHIELDED PAIR; TP = TWISTED PAIR (NON - SHIELDED); TYPE FPL, FPLP, OR FPLR AS REQUIRED. TNT1-5 001-022\0 STROBE CIRCUIT J J DEVICE NUMBER ANALOG LOOP NUMBER7— ` DEVICE NUMBER POWER SUPPLY NUMBER OUTPUT NUMBER /TSP -5 SPEAKER CIRCUIT7 CIRCUIT NUMBER DRAWING INDEX FA -0.00 COVERSHEET/INDEX FA -2.01 FIRST FLOOR FIRE ALARM PLAN RECEIVED DEC 5 2013 CITY OF TIGARD BUILDING DIVISION SEQUENCE OF OPERATIONS A. ANY SMOKE DETECTOR CAUSES GENERAL ALARM. B. ANY HEAT DETECTOR CAUSES GENERAL ALARM. C. ANY PULL STATION CAUSES GENERAL ALARM. D. ANY DUCT DETECTOR CAUSES SUPERVISORY ONLY. FIRE ALARM WIRE LEGEND A. 16AWG/2, TWISTED SHIELDED PAIR. B. 14AWG/2, TWISTED PAIR, NO SHIELD. CITY OF TIGAP.2 Approved . `. ..(da).[ [ ] Conditionally Approved .............. [ ] See Letter to: Fo I low .................. [ ] Att c ed ................ ] PermitNylnber. (3—val i Add Y By: Approved pians shalybe on job site.. OFFICE COPY THIS DRAWING AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, R11"HOUT EXPRESS WRITTEN CONSENT OF SIEMENS BUILDING TECHNOLOGIES, A DIVISION OF SIEMENS INIDUSTR'r INC. ALL REPRODUCTIONS SHALL BARE THIS NOTICE. } m HUI O_o (f� a \ U U) W W w 0 0 0 ZD N N M W Q o � N O Z p " =;0�<pERTIFIC�TiOh �� w HARIE OOHES.OET NICET NO. 0931562 "e FIREAARM SYSTEMS �' NkfT LEM E,� s- Vf T V � LU "= U T � LUN� UI J �o n L E O E :0-- 0 =` N w Q J 0 J � Q LU �Q z LlJ = Q Q Q 00 U) ( z Zz0 O Q QW 0 U) W F- or -DIY 0 z 2c� w0 < C Cn ENGINEER: James Calhoun SCALE: NOTED DATE: 12/05/2013 JOB NO: 440P-141608 CHECKED BY: CJH COVER SHEET GENERAL NOTES DRAWING INDEX LEGENDS FA4,00 ZUMIEZ FA2.01 SCALE: 1/8"=1'-0" Sheet Size: 24"06" = 1:1 Scale NORTH NOTE: PARALLEL BRANCHING OF ANALOG LOOP IS NOT PERMITTED FOR CLASS—.A CIRCUITS. ANALOG (DATA) LOOP 5 1 a FROM FACP OR PREVIOUS _ ( ) DEVICE 6 1bI T131O ANALOG (DATA) LOOP TO � O NEXT DEVICE a (—) TT1322 TB3 (OPTIONAL) REMOTE ALARM INDICATOR RL—HW OR RL—HC 1 DB -11 SMOKE/HEAT DETECTOR BASE Y�LI��►[i in SHEET NOTES 1. INSTALL (2) NEW SPEAKER/STROBES IN SUITE A04 AS SHOWN. CIRCUIT TO FAPS LOCATED IN ELECTRICAL ROOM (FOR LOCATION FIELD VERIFY) - CONNECTION TO BE COORDINATED WITH SIEMENS FIELD PERSONNEL. 2. INSTALL (1) NEW SMOKE DETECTOR IN ELECTRICAL ROOM. (SEE DETAIL 1 ON THIS SHEET) 3. INSTALL TRI -R RELAY TO TRIGGER AND MONITOR NEW POWER SUPPLY. 4. INSTALL WHEELOCK PS -8 IN ELECTRICAL ROOM. (SEE DETAIL 1 ON THIS SHEET) or U m POWER SUPPLY (FAPS) PS -8 DETAIL FA2.01 SCALE: NONE m THIS DRAWING AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, 'MTHOUT EXPRESS WRITTEN CONSENT OF SIEMENS BUILDING TECHNOLOGIES, A DIVISION OF SIEMENS INDUSTRY IWC. ALL REPRODUCTIONS SHALL BARE THIS NOTICE. } 03 U Q_ 0 (n a \ 0 U) W Q NLNLJ N. 0 0 w M W �— o 0 N C51 Z 1 1 I I o GERTIF/a,r o GEZ J a2 HAR ES HES, CET NICET NO. W2662 FIREAIARM SYSTEMS o' 49L LEVE�N °J Z V N Lu N_= U o�xp C+ do 0 W N L �o Ni7 _ ro C O �w u .. in 0 Q J O Q W LLJ J 13f c3f Q U O Q Qw R=0 Lu of Q w -- Z�0 c=)(r C0 =cn� w0 U) LL o)F- ENGINEER: ENGINEER: JAMES CALHOUN SCALE: NOTED DATE: 1210512013 JOB NO: 440P-141608 CHECKED BY: CJH Zumiez SUITE A04 FIRST FLOOR FIRE ALARM PLAN FA -2.01