Plans B -UP2016 - 00024 RECEIVED #3082 Z `� CODE SUMMARY TENANT IMPROVEMENT JAN 2Z016 MARTIN W. HANSON 0 ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND CITYOTGAi"itD tJ� LOCAL CODE REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: for BUILDING DIVISION CLA KAM S, OREGON,�O • 2014 OREGON STRUCTURAL SPECIALTY CODE sw 72ND AVENUE J-/rrm rT1TI I u 111111 UTrTMM 1 • 2014 OREGON MECHANICAL SPECIALTY CODE (OMSC) F cmn ' � 1""1 • 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) TAPPLASTICES PROJECT #15910 E Y w A F • 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) • 2014 OREGON FIRE CODE (OFC) PROJECT NARRATIVE F-4• ASCE-7-10 - W V�NER� PA GUlu CONSOLIDATEDBUILDING • ICC/ANSI A117.1 -2000 PROJECT CONSISTS OF REMODEL WORK TO 3,782 SF OF EXISTING SPACE. CONVERTING A mw S° BLOCATION • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE HOT YOGA SPACE TO A RETAIL SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO H C DRYWALUMETAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL U � o WORK TO MEET ADA REQUIREMENTS. BURLIN 74TH AVENUE WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT z SW 0 0 0 M 1 SITE MAP PLUMBING WORK FIRE PROTECTION SPRINKLERING A-1 1°=300' HEATING, VENTILATION & AIR CONDITIONING WORK eq ELECTRICAL WORK, BOTH LIME VOLTAGE AND LOW VOLTAGE p°` o TENANT FIXTURES/FURNISHINGS Z ceo 0 BUILDING INFORMATION 3 OWNER: PACIFIC REALTY ASSOCIATES, L.P. 15350 SW SEQUOIA PKWY#300 �A4 a w PORTLAND, ORE 97224 \ (503) 624-6300 (PHONE) (503) 624-7755 (FAX) \X, /, BLDG. #-. OBP III BLDG. A (3obp214) N Q /" \ /" AREA OF WORK .n A `� CONST. TYPE.. III-B M EL 3 THIS BUILDING HOUSES SEVERAL SEPARATE TENANTS INCLUDING THIS TENANT. THET T F- "/` / - EXISTING BUILDING IS A SINGLE STORY BUILDING OF 26,500 SF AND IS FULLY ¢ M SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 65 FEET. 03 7:L C I I I I I I I I ------------------------ / ACTUAL BUILDING AREA TOTALS (� I I 1 I I I 1 I Pq A2 OCCUPANCY = 81560 SF a. - t B OCCUPANCY = 61310 SF M OCCUPANCY = 61531-6FFXI Q I I -. 'a S1 OCCUPANCY = 4,423 SF TOTAL 25,824 SF F b T M 4s4A 19761 SF E1 MIXED OCCUPANCY - NON-SEPARATED USES. (IBC 508.3.2) f SALES 2 OVERALL BUILDING PLAN � 500ALLOWABLE AREA (A2/A3 MOST RESTRICTIVE) NF A-1 1/3211= 1'-O" A2 9,500 + 28,500 (300% SPRINKLER INCREASE) + 7,125 (75% INCREASE FOR FRONTAGE) = 45,125 SF. V 1k_ �--� Hslr 251824 SF < 45,125 SF - NON-SEPARATED OCCUPANCY ALLOWED 4a OFFICE TENANT INFORMATION '°' -- ------------------- -- TENANT: TAP PLASTICS w C-1- "CONTROL „CONTROL AREA V - OCCUPANCY AREAS, LOADS AND EXITS: p••� ��.. q�A o M 1,761 SF 59 OCC 2 EXIT � N .. EXISTING 1-HR SEPARATION WALL s-1 2,021 SF 5 occ 1 EXIT o a z � 2 w o » a En o � ° "CONTROL AREA 2" S1 REVISION 2,021 SF 1. n 9 SHOP 2. y o2 3. 3 / CITY OF TIGARD 4. 7 REVIEWED FOR CODE COMPLIANCE 5. F Approvedt {Vj� 6. z OTC: [ 7. I i I I L9 Address: .. .. .Suite ' 0 M ; 11 �— �� DRAWN BY: BREAK I HC RR Date:I PY� R. M. T. yo] rl`i DATE: 12/22/15 o/ OFFICE COPY BID/PERMIT SET F T INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY CITY OF TIGARD A( r' .,j LIGHTING EQUAL TO'I-FOOTCANDLE. �l�1 Approved by Planning Date: 026-1 ials: �S 3 BUILDING OCCUPANCY PLAN s EXIT PLAN Initial—,-n iti � z�A-1 1/32"= 1'-0" A-1 SCALE 1/8"= 1'-0" BUILDING DEPARTMENT USE 01 00 00 GENERAL DATA IAND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24'O.C.(OR ONE STUD PLUMBING-BREAK ROOM FIXTURES a. TRANSFORMERS TO BE ENERGY STAR LABELED. _ SPACING),EACH SIDE AND OPPOSITE SIDES. jS �''i, GENERAL REQUIREMENTS 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. 5. IN FINISHED SPACES FURR-0UT BUILDING COLUMNS AND EXTERIOR WALLS WITH 518'GYPSUM BOARD OVER - 1. ALL CONSTRUCTION WORK SHA LL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OFTHE OREGON METAL STUDS. 2. BREAK ROOM SINK ELKAY GECR2521 c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C STRUCTURAL SPECIALTY CODE,A ND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS #3082 _ 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. 3. KITCHEN FAUCET DELTA 100 QST OPERATION. EQUiP WITH 2-112 PERCENT ANFC TAPS AND FOUR 2-1C2 PERCENT BNFC TAPS. MAXIMUM - 2. VER{F1(ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 7, AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 4. 1/4"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL MARTIN W. HANSON NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK PATCH READY FOR PAINT. REQUIRED. . ASSEMBLY AND CASE_ 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING g. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO FAINT READY CONDITION. 23 00 00 HVAC :DESIGN/BUILD 9. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE VWtiREMOLD RC7 ` CONDITIONS PRIOR 70 SUBMITTAL OF A PROPOSAL SUBMITTAL OFA PROPOSAL SHALL BE CONSIDERED FLUSH POKE THRU SERIES OR EQUAL FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH �YC�A KAM S, {OREGON CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE WALL.CONSTRUCTION MATERIALS GAS METER LOCATION TO SEPARATE POWER AND DATA WITH 1"CONDUIT FOR POWER AND 2'CONDUIT FOR DATA t� - THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE INSTALLATION_ METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR 10.TELECOMMUNICATTON SYSTEM BY FUTURE TENANT. EXAMINED THE SITE AND INCLUDED N THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK TO TENANT'S MOVE4N. 11.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. V (� �� DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 2• FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. HVAC-BID PROCEDURE 12.OCCUPANCY CONTROL DEVICES SHALL BE LEViTON OR WATT STOP. LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE DESIGN FRAMING iN ACCORDANCE WITH AISI SG-673. 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT iS N 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEANUP. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TOASTM A446%446 M GRADE A(33000 PROPER WORKING ORDER. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND PROJECT #15910 PSI)G60. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE TRAY OPERATE 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 2. INVENTORY EXISTING H.VA.C.ROOFTOP UNITS AND SUBMITTO ARCHITECT CONDITIONS REPORT OF EACH IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR UNIT INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. AN APPROVED EQUAL 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. _ 3. LIST TONNAGE OF EACH UNIT. T � 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5tr THICK WITH TAPERED EDGES CONFORMING TO ASTM 15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA V 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-0FF MATS`TO PROTECT EXISTING G36' HVAC-DESIGN PROCEDURE BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. �] CARPETS. 6. WATER RESISTANT GYPSUM BOARD SHALL BE Wir THICKWITH TAPERED EDGES. CONFORMING TO ASTM USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL HVAC.SYSTEM PER DESIGN STANDARDS 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE LISTED BELOW. � - 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENTTO BE REMOVED. PATCH AND REPAIR ROOF C-630. DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOXTOI'HE SPACE ABOVETHE CEILING. A SECTION = MEMBRANE AS NEEDED, 7. AT TOILET ROOMS USE 51W USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO48'A.F.F. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,HVAC.CONTRACTOR SHALL SUBMITTOARCHITECT FOR OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OFA PULL STRING . REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED LO WALLS BEHIND OR ADJACENT LA PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. SALES LIGHTING �01 COMPANIES INCLUDE: LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) INCLUDE THE FOLLOWING: L PEERLESS BRUNO SOFTSHINE BRM9 2 54T5HO SPR 20180 SSH R4 GEB10 SCT LP835P F3/18 C210 BLKSCEP 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD WTHICK WITH SQUARE,REINFORCED, OII�V LT ADVANCE OR EQUAL(NO SYLVANIA BALLASTS) a. ARROW ROOFING, ALFONSO PEREZ (503)460-2767 a. DUCTING AND SIZES SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL 2. RECESSED LED DOWN LIGHT. LITHONIA LDN6 35/10 L06 AR LD 277TRW b. PACIFIC ROOFING, GUY BELT (503)6403163 b. SUPPLYAND RETURN LOCATIONS AND CFM 9. AT FRP,PLASTIC LAMINATE,ETC.,WAINSCOT PANELING INSTALL WATER-RESISTANT GYPSUM BOARD. SHOP LIGHTING c. GRIFFITH ROOFING, GREG STONE (503)643-1596 c. ROOF EQUIPMENT,SIZES AND LOCATIONS 1. RUUD LIGHTING TWO LAMP,H1-2 X 54-U-K-4,54W,T5HO FLUORESCENT27'/V. (EMERGENCY BATTERY PACK h 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM G1047. 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS d. UNITS REQUIRING DUCTED SMOKE DETECTION AREAS AND COMMON AREA FLOORS TO BE SWEPT OR VACUUMED DAILY. 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WiTH STO FINISH OPTION EB) SYSTEM. e. THERMOSTAT LOCATIONS AND ZONE/UNITASSOCIATED THEREWITH 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO O COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WiLL WALT-CONSTRUCTION EXECUTION f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS cn � - BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 1.`FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-0RILUNG OR SELF-TAPPING g. ZONE DIAGRAM ACTIVITIES. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW HVAC DESIGN STANDARDS - 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD ►�' RESTROOM FACILITIES. MATERIALS LIGHTER THAN 18 GA THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE UMiTED TO AREAS AS DESIGNATED AT 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS L 350 SQUARE FOOT PER TON. . I4 N INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. .e+CN' PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY - * a FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. COMMON BUILDING AREA BE USED FOR STORAGE. TENANT PRIOR TO CONSTRUCTION: Q CR 3. CUT STUDS SQUARE AND SET WiTH FIRM BEARING AGAINST WEBS OFTOP AND BOTTOM TRACKS. POSITION CD VZ 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)ATALLTIMES. a. EXTERIOR EXPOSURE AREAS '�' - STUDSVERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT ,,,�[� 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. - LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE b. INTERIOR AREAS,SiZE AND USE z JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 4pq 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, c_ CONFERENCE/TRAINING ROOMS cn N N ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP �{ �iO SD AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS_ d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. AND 24HOUR USE. t : C 11 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. THE PROJECT_ 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. C 0 V'l to 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. M�i �"'� WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE N Q x`X 20.PROVIDE"AS-BUILT DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" ZONES. .-�a 04 W - DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 6. COMPLY WiTH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 4_ ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 7. FINISH QUALITY: SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICALAND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. CONTRACTOR'S FINAL PAYMENT UNTIL'AS-BUILT'DRAWINGS AND O&M MANUALS HAVE BEEN RECEIVED AREA PROCESS TRADE NOMENCLATURE 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7112-TON MAXIMUM UNIT SIZE_ANY UNir IN EXCESS OF 7112 AND APPROVED. OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. 21.iT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, , FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED USG"FIRST COAT SAND AFTER TAPE/FINISH COAT(S) T HVAC UMTS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE H TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. . WHETHER OR NOT SHOWN ON THE DRAWINGS. SHOWN ON PLANS. 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS 11 _ 22.iTEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.LC.". 09 6519 RESILIENT FLOORING-VINYL COMPOSITION TILE SHALL BE PLACED SYMMETRICALLY INA LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. , _ 23."ALIGN'AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 1. EXTEND FINISH FLOORING UNDER CASEWORK. 9. CURBS: 14'CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW ROOFING. ..+ a PLANE,EITHER IMMEDIATELY ADJACENTTO ONE ANOTHER OR ACROSS AN OPENING. 2. INSTALL TILES IN QUARTER TURN PATTERN. 24.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. a PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF 04 0 O9 91 23 PAINTING CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. O 25.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN INTERIOR: I en 11 b_ UNIT MUST BE LEVEL SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. -00 TWD WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECTTO REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL 1. WALLS: c. CONDENSATE MUST BE TRAPPED AT UNIT. . REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. 7. SEISMICALLY ATTACH UNIT TO CURB IN CODE APPROVED METHOD. CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS DIRECTED AT CONTRACTOR'S COST_ b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WiTH MILLER'S 62M OR 8. ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN F 26.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S SiG LATEX ENAMEL INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND [� PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMITA MINIMUM OFTWOCOPIES OFALL 2. DOORS AND FRAMES: CLAMPED(S.S.WORM GEAR). .< Yl SHOP DRAWINGS FOR REVIEW AND APROVALTOTHE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 9_ ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUSTAND a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OFSEMt-GLOSS OIL V COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. CORROSION WITH OIL BASED PAINT(COLOR GREY). R7 b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WITH 27.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OFTHE FIRE PROTECTION SYSTEMS ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL 10.LOW VOLTAGE iN SEALTITE CONDUIT FROM BELOW ROOF LINE QIRECTTO UNif. DO NOT EXCEED BEND CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY PROFESSIONAL.ENGINEER RADIUS MANUFACTURER'S GUIDELINE. Q LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE c. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH 11.ECONOMIZER TO MEET CODE AND AS FOLLOWS: c (� INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX r 5 Y - CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK Ii TYPE OF CEILING TILE WHERE CAULK,AND FINISH WITH SATiN OIL ENAMEL a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. m APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WiTH SATIN toll b. BAROMETRIC RELIEF ON 5-71270N UNITS_ THE ARCHITECT PRIOR TO INSTALLATION. . ENAMEL IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,AND RE VARNISH WITH SATIN 28.COORDINATE ALL CONSTRUCTION SEQUENCING WiTH PACTRUST AND SCHEDULE ALL SERVICE VARNISH. C. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 3. CEILINGS: - d. 1 12 THRU 4-TON OSA INTAKE WiTH DAMPER. GENERAL 12.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. 14 a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRiOR ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. - 13.DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WiTH SUPPLY AIR. EDGES OF SUPPLY TO INSTALLATION OF NEW FLOORING. AIR SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING.b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH WITH MILLER'S 6200 OR 4480. 14.DISTRIBUTION DUCTWORK: A LEAD ROOF JACK,CLAMPED WiTH A STAINLESS STEEL CLAMP AND SEALED WITH VUL KEM 921 4. GENERAL NOTES: a. SPIRAL ONLY IF EXPOSED. POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. 01 73 29 CUTTING AND PATCHING a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OFALL PAINTSPLATTERS,DRIPS,OR ROLLER b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. SPRAY. C. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH L PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXTCOAT. MINIMUM R4.2 INSULATION NTH FSK BARRIER. BEING UNDERTAKEN. . 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1'WIDE STRAP. EXPOSED DUCT MUST HAVE ALLTHREAD RAGS AT THE END OF EACH DAY. HANGERS AND FULL DIAMETER STRAP UP TO 18"O. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. 3. PERFORM CUTTING USING METHODS LEAST LIKELYTO DAMAGE ELEMENTS TO BE RETAINED. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 . 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THATVISUALLY MATCH EXISTING ADJACENT AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. DEGREES. SURFACES TO THE FULLEST EXTENT POSSIBLE e. PROTECT WORK OF OTHER TRADES. f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. 5. PATCH WiTH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. f. PROVIDE'WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. g. ALL DISTRIBUTION DUCT WORK BE INSTALLED MIN.2r FINISH CEILING. I cn 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3 x 12'LONG REBAR DOWELS AT 24'O.C. MIN.WITH 10 00 00 SPECIALTIES 15.FLEX DUCT WILL BE NO LONGER THAN 6 FROM RIGID DUCT DOWN TO DIFFUSER. MIN.6'PENETRATION INTO EXISTING CONCRETE AND MIN.OF 6 EXPOSURE INTO POUR BACK CENTER 16.DIFFUSERS. I 1, - DOWEL IN SLAB. 10 2813 BREAK COUNTER 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN r� ADDITIONAL COST. 10 4416 FIRE EXTINGUISHERS TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL 08 10 00 DOORS AND WINDOWS 1. FIRE EXTINGUISHER 2Ai0 BC (WALL MOUNTED OR LN SEMI RECESSED CABINET AS INDICATED ON PLAN) b- GYP.BD.CEILING;SUPPLY-CURVED BLADE W1 OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN - ) TITUS 350;EXHAUST-METAL OR ALUMINUM-12"x 112'EGG CRATE DESIGN TITUS 50F. 1. REUSE EXISTING DOORS AND FRAMES WHERE POSSIBLE 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. c. All SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUGTAT/OR NEAR CLOSEST �,rl j 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 1200 00 FURNISHINGS WYE BRANCH. El a. . BAXTER AND FLAMING. (503)225-0486 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT .b. D&D DOOR (503)205-5533 COMPLETION. 12 23 16 CABINET SPECIFICATIONS 17.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE c. BENSON INDUSTRIES ( ) 7 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. HONEYWELL COMMERCIAL GRADE WSIONPRO 8000 TOUCH SCREEN MODEL YB822IXHU0.3 WIEREPOSS/BLE a N d. GRANT SUPPLY (360)887 0647 APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL N .P374=2800 -7 DAY N 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O cn t- 3. DOOR AND REUTE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY_ MOUNT ATADA HEIGHT(MAY O% MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR_ _ 3. HiGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES,INCLUDING 4"TOE TICK EDGE BANDING REQUIRE CHANGING HEIGHT AT REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM . p", (MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS THERMOSTATS AND BALANCE SYSTEM. - 4 a 4. EXTERIOR DOORS AND FRAMES TO BE HOLLOW METAL FRAMES OF ONE-PIECE WELDED CONSTRUCTION, OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD En Q 14 GA.GALV.SHEET STEEL DOORS,SDI-100,GRADE 11,SEAMLESS EDGES,16 GA.GALV.SHEET STEEL MELAMINE FINISH. 18.THERMOSTAT LOCATIONS TO BE REVIEWED BYARCHiTECT PRIOR TO INSTALLATION.. ,, FABRICATE DOORS AND FRAMES WITH HARDWARE REINFORCING WELDED IN PLACE. 19.EXHAUST FANS: p t- 4. TOE KICK PLYWOOD 4"H WITH P LAM COVER Q 5. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT ;� ►3 FRAMES AND HARDWARE TO MATCH EXISTING BUILDING5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16'PARTICLE BOARD WITH MATCHING P4 AM OR STANDARDS. PVC EDGES. CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TOTHE EXTERIOR.. W Q fJ] 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, CFM WITH A u I t- 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. SONE RATING OF,9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. in aI - 7. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. - Q CTS 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING tI'>t Q 8. ALL DOOR HARDWARE SHALL BE INSTALLED NTH A 5'BACKSET. MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. TJ3 Q "4 a 8. HINGES-BLUM#75M3580,110 DEG.SELF CLOSING CUP ON(OR EQUAL). - . 9. DOOR FINISH SUBMITTAL'CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE - HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, . APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. CONTROLS AS REQUIRED BY DESIGN.COOKACE-0 SERIES OR EQUAL REVISION SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 10.PULLS-96 MM GTO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEETTHE ABOVE MINIMUM REQUIREMENTS - SAMPLE. 1 LGENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINKTEMPLATE(SPEC SHEETS)FOR EACH SINK INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL OF A ROOFTOP MOUNTED FAN. 1. . 10.ALL INTERIOR GLAZING SHALL BE TEMPERED. CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH TO BE SEALED. MINIMIZE COUNTERTOP BUILDUPS AT FRONT AND BACK OF SINK CUTOUT TO 21.HVAC TESTING. 11.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WiTH A SCHLAGE MORTISE DOUBLE 2• CYLINDER 20-013C 'C KEYWAY;SOLID BRASS;WiTH ADAMS-RITE CAM AND COMPRESSION RING 1 118"LENGTH ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. 12.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P4AM TOP ON PLYWOOD DECKING AND 4"BACK EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WiTH - 3. 12.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOOR H UP SPLASH ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12'D X 36"H-ATTACH TO WALL APPROVED PLANS AND SPECIFICATIONS. - S.TOUCH WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 26'D. MICROWAVE SHELF 18'D WITH 3'RADIUS OUTSIDE b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN FINISH FOR AS NEW LOOK 4, CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJ.HOLES AND POSTS(1 AT BASE,2 AT UPPERS). ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 13.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK 09 00 00 FINISHES 13.WORKICOPYISTORAGE CABINETS-BASE CABINETS WiTH P4AM TOP ON PARTICLE BOARD DECKING. SCRIBE c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND 5. COUNTERTOPS TO WALLS. ALL CABINETS OPEN MELAMINE STANDARD INTERIORS NTH DRAWERS,U.N.O. FILED WITH PACTRUST. GENERAL UPPERS AT 15'D X 30"H -ATTACH TO WALL WITH FRENCH CLEAT. BASES AT 24"D X36'HAT COUNTER AND 22.PROJECT CLOSE OUT DOCUMENTS REQUIRED: • COUNTERTOP_ P-LAM AT TOEIBASE. ALL SHELVES ADJ.HOLES AND POST(1 AT BASE,1 AT UPPERS)_ - 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 14.WORKCOUNTERTOPS-COUNTER TOPS WITH P-LAM ON PARTICLE BOARD DECKING_ SCRIBE COUNTERTOPS ?„ 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING- TO WALLS. PROVIDE GROMMET HOLES ABOVE ALL POWER AND DATA LOCATIONS. PROVIDE STEEL MID SPAN b. ELECTRONIC PDF FILE OF THE AudoCAD FILE ABOVE_ SUPPORTS AS NEEDED EQUAL TO WORK STATION BRACKETS AS MFG.BY &M HARDWARE,INC a. FT.iUUOR COVERINGS,BASE AND TRANSITION STRIPS c. HARD COPY OF AutoCAD FILE ABOVE. . S. b. PLASTIC LAMINATES (888 47-WM. - 21 00 00 FIRE SUPPRESSION :DESIGN I BUILD d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDINGTSTATS. c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) e. COLORED ZONE MAP WiTH THERMOSTAT LOCATIONS INDICATED. . 1. ADJUST EXISTING SPRINKLERS PER CODE.SPRINKLER LAYOUT N ALL HARD CEILING AREAS(GYPSUM d. PAINT BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 26 00 00 ELECTRICAL :DESIGN i BUILD DRAWN BY: - e. TiLE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS 22 00 00 PLUMBING GENERAL RM.T. f. TOILET PARTITIONS GENERAL REQUIREMENTS : 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. ►�+� g. HARDWARE EXCEPT FOR DED FOR ALL SHUT OFFVALVES,CLEAN IHORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD.1 I DATE: 12/22/15 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK OUTRACC SS DOORS,AND FLOOR DRAINS NSACTOR TO SUBMIT LAYOUT ON ATIONS AND TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING $ID/.CE+RlWT ,,TET 09 21 00 GYPSUM BOARD I 112. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. GENERAL INSULATED. 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER." 3. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. - 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8'THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH LOCATION. 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER 1"TYPE 5-12 SCREWS 12'O.C.UNLESS OTHERWISE NOTED. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 4 FLOW SETTING TO PROVIDE HPOINT OF DEMAND WATER TEATING RANGCH POWER 105 TO 120 DEGREE . CONTACT DEL RP2P SHER�SUPPLYWFOR R TENANT'S MOVE-1N. FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. AVAILABILITY,(503)236148. 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUALTO 1-FOOT 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH CANDLE. COAT. PAINT AS INDICATED. IIIIIIIIIIIIIIII - 6. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN'MODEL EXPBURWH RED LETTERS,WHiTE HOUSING, 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5 i TYPE X GYPSUM WALLBOARD,EITHER - WITH BATTERY BACKUP. AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT24"O.C. FASTEN 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDEI I A 2 WITH 1"TYPE S DRYWALL SCREWS 8"O_C.TO VERTICAL EDGES AND 12'0.C.TOTOP AND BOTTOM RUNNERS. WHERE N POWER FROM THE R TO FUR SYSTEM_ SIZE TO BE BIDDER DESIGN. Ali t i �1 �� } #3082 } - MARM W. HANSON � �CLA KAM , OREGON, „ ---------------------- �` ---------------------- \ � PROJECT#15914 / J - } �-'_ f L -411 �-i F✓ M = rr- ZZ �.-L-J- I--L-J--1__L-J-J F-zi- I I I t I t t' 1 111 I IZ:t- I I ! I I I I N --I---I---t -I--+--h--I- i • �ZZtz I N `It _ I \ I--t--I---I--t--1----11-�-`�.-L-J- 1--L-J--1__L_J_J 1nQ/j �„o"✓ I I I^� �1�111,,� --T--r-'t--+--t---I I---I--+--1---t--I —404 04 44 - 11 - 1 t fill - -(- 1 F- 5 -r, L L L J J y1 I k - I /- 1 :�� t 1 1 I 1 t 1 1 1 1 I 1 I I I 1 T--r-,---1---1---I--1 { 11 , I---t--L-�--t--L- t---i---r--�--T--r--l-'-+--f---�1=���\�-�--+--1---1-� - Ztz- I t I I I N C-----j � 0 ------------- ------ - -------- r� =-_ L_�--L_J__�--L_J__1__L;J_ 1__�_J__1�_L_J_J 1 f1 11 (� If 11 �./ ���/ % \ it fill �y 1 ,i l I I 1111 l -- it 40" LLQ ! \ / \ /} � It-it, \\ y \// // --�> - 1 F F ------------ 1 DEMO PLAN 2 REFLECTED CEILING DEMO PLAN Z z _ A 3 SCALE 1/8"=1'-0" A-3 SCALE 1/8"=1'-0" a ,� � N p _ Q z W O rn a � � a or-404 REVISION 2. 3, 4. 5. 6. DRAWN BF: _ R,M.T. DATE: 12/22/15 BID/PERMIT SET. �.` #3082 FINISH MATERIALSMARTIN W. HANSON ' ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. STAINED CONCRETE STC DYE-SEAL GRAY BASE CARAMEL �CLA KA M S, OREGON,�„ SHEETVINYL Ntt ARMSTRONG MEDENTONE H8310 ROCK BROWN (WELDED SEAMS) � �� ` .� 4� ,. VINYL COMPOSITION TILE OF VCT TO BE DETERMINED - ° r BASE PROTECT#15910 - RF BURKE 4-FLAT RUBBER BASE,(COLOR T.B.D.)AT ALL CARPET AREAS. _ RC BURKE 4-COVE RUBBER BASE,(COLOR T.B.D)AT ALL HARD SURFACES. _ RELOCATE 14C r , PARKMG STALL PAINT: �I �� , i •�� P117-1 MILLER 4480 PREMIUM SATIN(COLOR T.B.D.).SATIN LATEX. PT-2 MILLER 4480 PREMIUM SATIN(COLOR T.B.D),SATIN LATEX (ACCENT COLOR) LAMINATE: H O `� i ` PL-1 WILSONART (COLOR T.B.D-).AT ALL FACES PL-2 WILSONART (COLOR T.B_D.),COUNTER,B.S.AND SELF-EDGE. PL-3 WILSONART . (COLOR T.B.D.),RETAIL CABINET TOP AND SELF EDGE. w CAB PULLS 626 SATIN CHROME I ` DOORS.HARDWARE AND FRAMES HARDWARE 626 SATIN CHROME FRAMES BROWN TONE ��` CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS_ ADJUST WALK AND CURB ` Q FOR RILL CART ACCESS RELOCATE FIG � z � FROM ASPHALT TO ENTRY. PARKING SIGN `— -------- --------- ------ ` ----_----------------- 0 o �o ABBREVIATIONS BRK BRICK PAVERS a N Q CP-# CUT PILE CARPET • ' CR CHAIR RAIL j�Li► O� p 4 NEW PAIR s X �� E EXISTING ✓✓' ;z P" 40i n GLASS DOORS ETR EXTEND TO ROOF �yo t` FWC FABRIC WALL COVERING TW N N GT GROUT CC C ® mnxamq PGWB PAINTED GYPSUM WALL BOARD Cell en .-..-. PL-# PLASTIC LAMINATE PLW PLASTIC LAMINATE WAINSCOT �O +�+ fi POT PORCELAIN TILE .-rt a a W SANS POTW PORCELAIN TILE WAINSCOT _ / 100 1 RE CEIL NG r-" I RE-U5E CEILMG FANS PTS# PAINT RC RUBBER BASE COVED \ \ i RF RUBBER BASE FLAT E-STC STC i Ext�osED To SAT SUSPENDED ACOUSTICAL TILE SC SEALED CONCRETE �SSTC STAINED CONCRETE IR HVAC,PIPES, / SHEET VINYL C NEW TMY FRAM I ETC,BLACK V / I VCT VINYL COMPOSITION TILE WITH SGSI q I ® 131 WBC WALL BOARD CEILINGSAID HEAD CA-456 BY TENANT WCG WACORNER GUARD IL 0, O MOUNT POWER Arlo I WOC WALK OFF CARPET in t DATA INTO CABINET } M � -- -- I WW WINDOW WALL I / ® OFF] RE 115E CEILMG FANS -4 EL 101 10 ■` 4,- ' — — - — — .� �. ... .. — — — ''"' fi SHOP ELECRICAL REQUIREMENTS d I o 8.�. E 8._m. 2'0' 5-TI. / 2 TUBE EthT-5 O L. ° Q (2)NEW 8 X 4 TIMELY FRAME / {� , WITH STOPS.48'SILL I� IRSTRUCTURE Table Saw X 230 13 1 GLASS BY TENANT PAINT CEILING, Belt Sander X 230 8 1 I HVAC,PIPES, Band Saw X 115 15 1 ETC,BLACK E :LooRPOWER aui fi fi E i ( Dust Collector X 115 11 1 BAND saw I Air Cleaner X 115 4.5 1 Q E-STC E-SC • DUST COLLECTOR (VERIFY LOCATION fi Air Compressor X 115 15 1 TENANT) RE-USE CEILMG FANS Drill Press X 115 15 1 � I - 21 I Edge Router X 115 15 1 - L------- ---- --- ---- ---- -- u� \ ."------ ---- Scroll Saw X 115 2 1 _ .� Spindle Sander X 115 3.5 1 LU SHOP i Standing Buffer X 115 2.8 1 - 102 i Strip Heater X 115 15 1 FLOOR POWER FOR fi \ fi Table Router - X 115 15 3 a TABLE ROUTER \ RE-USE CEILMG FANS Wet/Dry Vac X 115 5.8 1 (vERFY LOCATION WITH W-USE CEILING FANS T) PROVIDE POWER FOR ABOVE EQUIPMENT.LOCATIONS BYTENANT EVIOSED TO ) — — — 55 ROOF STRUCTURE i PAINT CEILNG � HVAC.PIPES, m .n w ue� ETC,BLACK f i BREAK HC RR ' r4 - 103 45' 104 ' Z 2 0' 0 v 66'MICRO_ : .- 1 N NEWW� N CABINET 1� AND SINK d � � 9 0 C�.� H J G H o REVISION - CONSTRUCTION LEGES 1. 1 PARTITION AND POWER PLAN 2 REFLECTED CEILING PLAN A-4 SCALE 1/8"_ 1'-0" Z� A-4 SCALE 1/8"=1'-0" Z Q EXISTING TO REMAIN 2. EXISTING TO BE REMOVED 3. ® ns NEW STANDARD WALLT08'U.N.O. 4. o _ ® As NEW WALL TO ROOF STRUCTURE 5. DOOR SCHEDULE DOOR DATA FRAME DATA HARDWARE 6 DUPLEX RECEPTACLE B ELECTRICAL PANEL Fire RatingRemarks Mark = FOURPLEX RECEPTACLE Q POWER J-BOX 7• Mark Door Size Thk Cors veneer Finish !-iarTd Type Frame Depth Hardware Manufacturer Finish Function g. 100 PR 3'-0' x 10'-0. 11/2* -- ALUM/GLA55 - NA -- • -- 5' PUSH/PULL/GLOSER/DEADBOLT ADAMS RITE BLDG..STD. PANIC HARDWARE RH ACTIVE }00 D� DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA - 101 3'-0' x 8'-0' 13/4' SC OAK WATCO Left • TIMELY 11 4 1V8' LEVER/LOCK/CLOSER(D SERIES) SCHLAGE 626 SATIN CHROME AL53F'D -- 101 102A 3'-0' x 8'-0' 1 3/4' FOAM HIGH-IMPACT TEXTURED THERMOPLASTIC R1 ht • -- 4 -1/8' PUSH /PUSH SCHLAGE 626 SATIN CHROME,— VISION WINDOW 102A �� EXISTING ELECTRICALTO REMAIN FeR FIRE EXTINGUISHER IN RECESSED CAB. DRAWN BY: 1028 PR 3'-0' x 8'-0" 1 3/4' FOAM HICsH-IMPACT TEXTURED THER'TOPLA5TIG NA • -- 4 ?/S' PUSH /PUSH SGHLAGsE 626 SATIN CHROME -- VI510N WINDOW EACH LEAF 1028 �t FLOOR MONUMENT W/SERVICES SHOWN FEs FIRE EXTINGUISHER SURFACE MOUNTED R.M. T. SPECIAL OUTLET THERMOSTAT FINISH SCHEDULE DATE: 1p2�/,222/15 � WALLS TEL/DATA MUD RING Wrr}i PULL BID/PERNUT SET RM" NAME FLOOR BASE CEILING CLG. REMARKS RM* NORTH EAST SOUTH WEST HT. ® PEERLESS 2-TUBE T-5 FLUORESCENT LIGHTING ® SUPPLY DIFFUSER _ 100 SALES STC 4' RC E-PGWB WW F'GWE3 FGue ETR 14'-0' -- IPSO 20180 LIGHT DISTRIBUTION ® RETURN DUCT 101 OFFICE 5v 4' RG PGWB PLW-E-PGWB PCsWB E9-FCsW8 WBG 9'-0' -- 101 _ - ® RUUD LIGHTING 2-TUBE 7-6 FLUORESCENT - 102 SHOP 5TG 4• RG FGIUB PGWB FGWB PGSUJB ETR 14'-0' -- 102 FUCTTURE WITH MOTION SENSOR AT EA LIGHT. EXHAUST FAN 103 BREAK JE-VCT E-4'RG E-F'3� E-F'GWB E-FGLU5 E-PCA05 JE-SAT 5'-0' -- 103 104 HC RR 5V 4• RC FPC-U1B PLW-E-FGLLe PLW-FGaWB FGU)B WBG 9'-0' INSTALL BASE OVER f LW 104 RECESSED LED FIXTURE nie SPRINKLER HEAD : e EXIT SIGN(LED RED) Cf CEILING FAN s A-� #3082 MAUN W. HANSON -240' BLDG.STRUCTURE ABOVE —Q— —� a o — 3@' —DEFLECTION CHANNEL tJ ,CLA KAM S, OREGON, 2' RADIUS 24' 132' 24' 2' RADIUS CAULKIts IN 1/2'SPACE p CORNER CORNER 'dlfOF S? R-11 BATT INSULATION a � Ilu _ cq a a 13 `4 PL-3 _ PL-3 11 PROJECT#15914 6'MTL.STUDS 16' O.G. SOAP PAPER TOWEL SAN.NAP. PAPER TOWEL/ RECESSED A-4 @ PL-3 A-4 w DISPENSER . DISPENSER DISPENSER DISPENSER/ TOWEL 5/8' TYPE X GYP.BRD. DISPENSER PL-3 H > BOT14 SIDES SCREW ATTACHED r _ CENTER LINE OF STUD V E 2'RADIUS 2'RADIUS CORNER tO CORNER �..� R-11 BATT INSULATION v a 9 WABINET PLtilr 4' RUBBER BASE TYP. p M A-s SCALE ln"=1'-0" RETAIL DESK ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN ANCHORS AT 12'O.C. SEAT COVER TOIL.PAPER/ GRAB BAR MIRROR A-5 A-5 DISPENSER SEAT COV.D15PI Q O SAN.NAP. 30' 24` EQ EG2 EQ EQ EQ. 24' 3@' 30' �_ M DISPOSAL 11. 12' _._.18• 41. ` 1 2 RILL HEIGHT WALL s ACC. - MOUNTING HEIGHTS PL-3 ►2 PL-3 PL-3 A-s SCALE V = 1'-0" A-5 NOT TO SCALE - 1 3 FIXED SHE v FIXED SHELF FIXED SHELF FIXED SHELF FIXED SHELF PL-3 i� Mtn —BLDG.STRUCTURE ABOVE _ _...—CAULKING IN 1r1'SPACE v ADJ_SHELF Nt ADJ.SI-IEEE ADJ_SHELF ADJ.SHELF ADJ-SHELF ADJ.SHELF ADJ.SHELF y' PL-1 r' b H cl,C14 PLYWOOD DECK WITH SHEET —DEFLECTION CHANNEL M _ DE METAL SCREWSOVER AREA L INDICATED ON PL-I BASE PL-I BASE M 0 PLAN 36' 36' 36' 36' 36' 3�� I3� 3' .-i a PLO cwtt N x rti 1@� MAX SPAN 8@0525@-54 METAL STUDS AT 16'METAL ALIGN WITH WALL STUDS to CABINET ELEVATION 11 CABINET ELEVATION F.G.INSULATION METAL CEILING STUD LOAD CHART MAX.SPAN 10' - A-s SCALE in"=1'-0" RETAIL.DESK A-s SCALE ln"=1'-0" RETAIL DESK F MAX SPACING 16` MAX.PONT LOAD 315 LB/STUD 30' 24' 132' 24' 30' 30' 5/8'GYP_BDA SUSPENDED CEILING ^ W 0 d 11' 42 18' i2` _ 6' 3625131-33 METAL STUDS AT I6'O.C. 1 ' N O' - 3— . PL-3 PL-3 —� _E - M 5/8'GYP.BD. EL 5/8'TYP WR CENTER LINE OF STUD GYP.P BD. .3 2'Fls_INSULATION! m PL-1 PL-1 PL-I v m PL-I 2` ttoA 4'RUBBER BASE-M'. m d M 6'MAL BASE ATTACH BOTTOM TRACK TO SEE FINISH SCHEDULE FLOOR WITH POWDER DRIVEN FOR MATERIAL FINISH FLOOR ANCHORS AT 12'O.C. v� PL-I BASE PL-I BASE PL-i BASE -v� PL-1 BASE A FINISH FLOOR-TOP OF SLAB } _j3. 2 REST ROOM WALL SECTION Q A-s " = f_ " 12 CABINET ELEVATION �3 CABINET ELEVATION ALE 1 A-s "- " A-5 "- " SC � � SCALE In 1-0 RETAIL DESK SCALE In -i-0 RETAIL DESK Q 1' 163' 332 331, I' _ - AD_"SHELF C to TYPICAL STUD `r' PL-1 ADJ.SHELF MICRO SHELF AT 18. DEEP WITH 2' n RADIUS CORNERS I2' F INSTALL STUDS WITH SAME TYPICAL TRACK OPEN BACK —E E--� DIMENSION(10MIK)FOR PROVIDE PAPER BRIDGING ALIGNMENT : f TOWEL DISPENSER PL-2 I' 36 25 24 12 BACK SPLASH POWDER DRIVEN a N ANCHORS AT 24' O.G. 1 aria SINK i� 41- (1)*10-16 SCREW "' n PL-1 –' Phi PER STUD FLANGE n — PL-i O 'v OPEN BASE P-LAM BASE W z '3 V 0 3 WALL BASE DETAIL �4 CABINET ELEVATION a � o = A-s SCALE 3" = 1'-0" A-s SCALE in"=1'-0"BREAK courrTER cn O a, REVISION 30' 30' L 1S, 18. 12,— -- 2. 3. - LITE KIT WHERE SPECIFIED - - FRAME TO MATCH DOOR 4. PROVIDE WC SIGNAGE 6' 6. FOR ALL NEW AND -- EXISTING HC RR'S FIXED SHELF 5 2'-0• 2' KROY '1835201 BLACK(MEN) _ 6. KROY "2835209 BLACK tWOMENI 2' 7. _ — g. w m ADDITIONAL SWITCH , Au GANG LOCATI - �. R M sY. •UA DATE: 12122115 BID/PERMIT SET W v ELECTRICAL °� a OUTLET OR J-BOX WDERCU ooc as cA co e v AREA e REWRE,Ta CLEAR i4 �, v .fl EE FLOOR FINISN 1. 3. 4 MOUNTING IHEIGMS 1s CABINET SECTION 16 CABINET SECTION A-S SCALE 1/2"= 1'-0" A-s SCALE I"=1'-.0" A-s SCALE 1"=Y-0"