Loading...
Plans (2) BUP2015 - 00256 RECEIVED CITY OF TIGARD AUG ing 5 2015 Plan Approved by r Q Date: F z Initials: �' _ _ � Z o J Lu r If LU Lu P �W o o I o� 1 o I o WASTE MANAGEMENT AREA U � I ILJ � I Q CITY o TIGARD 'REVMWED FOR CODS COM LUNC$ ' + ! p� oTE Permits F, w ----- --- ----------- 14 0 ---------- J r.... � N --------- ---- ---- -------------------- - uite#: Br. Daus SW FREWI NG STREET WORKING AREA(2ND STORY) �S�l z SITE PLAN o Scale:N.T.5 OFFICE COPY iu Qz Q—/ � Q CODE SUMMARY PROJECT INFORMATION PROJECT DIRECTORY VICINITY MAP L ~ CONSTRUCTION CODE:2014 055C: ADDRESS:9975 5W FREWING 5T A 01 :51TE PLAN k INFORMATION _ TYPE OF OCCUPANCY: 'B" TIGARD OR,97223 ( „ STATE ID:25102CB03200 A 02:A5-BUILT FLOOR PLAN R BUILDING CONSTRUCTION TYPE:V-B - t j ALT ACCOUNT#P400043 A 03 :PROPOSED FLOOR PLAN — '- PERMIT SET: j SPRINKLERS:NO PROPERTY ID:W257495 �\ 1 �� 1 OCCUPANT LOAD FOR TYPE OF U5E COUNTY:WASHINGTON A 04:REFLECTED CEILING PLAN OUTPATIENT ROOM - 100 GP055:7G9 5Q./100=8 PEOPLE ZONING:CG 5 1 :BUILDING SECTION AND DETAILS REVISIONS: STORAGE-300 GP055:G8 5Q./300= I PEOPLE ODOT DISTRICT:215 E I :ELECTRICAL PLAN EXERCISE ROOM-50 GROSS:2G7 5Q./50= 5.3=5 PEOPLE CHECK SHEET: WAITING ROOM- 15 GR055:2G7 5Q./15 = 18 PEOPLE _ OFFICE- 100: 12 5 5Q./100= 1 PERSON SCOPE OF WORK: .� J DATE: 8/22/2015 TOTAL=33 PEOPLE TENANT IMPROVEMENTS TO EXISTING"B"OCCUPANCY"THERAPY CLINIC' a NUMBER OF REQUIRED EXITS: I -HAVE 3 ADDING PARTITION WALL5,HAND SINK5,INTERIOR DOOR5,WINDOWS r �� A O LONGEST TRAVEL DISTANCE:75 FEET-HAVE 45 FEET ' � I RELATED ELECTRICAL,PLUMBING AND MECHANICAL WORK 5CALE: N.T.5 i F o LU �a ® C �IDm �i w z o Z0 , 20' 48'-3" 3'-2" Q w 3' 7' 6' 8' G. T 1 1'-3" W SFO LLJu I _ N EXIST.BALCONY EXIST.BALCONY Zv c DN. 36"x96" 36"x96" WALL NEED TO REMOVE Z g o ----- J LL O � EXIST.ELEVATOR N J CD i 20'_9" 20'_2" ———__ m m EXISTING STORAGE O ----- N N LLJ N N N N z O LLJ C, — 36"x96" Q i LL- Ln 1po I PERMIT 5ET: 5-6" 7' 5'-6" 11'_7" 8'-8" 3'-10" 8'-4" 4 I-5" 20'-10" 62'-3" REVISI ON5: I CHECK SHEET: j AS - BUILT FLOOR PLAN 7 Scale: I/4"= 1'-0" DATE: 5/22/2015 I A 02 i I 5CALE: 114'= P-0" i z � F Q ° pw Z 02 z�� c� , 20' 4&_3� 3 2 0 O w 19'-6.. 8'-8" 20'_1 _ }U p� 3' T 2'-6" 3'-6" 3'-6" 4-6" 4-2" I'-10" 7' I I'-3" W =O w TI-115 DOOR TO REMAIN UNLOCKED s O WHEN BUILDING OCCUPIED" N EXI5T.BALCONY EXIST.BALCONY N fn N 36"x96" 5'-7" \ 46"ACCE55115LE COUNTER \ 5OFFI LINE ABOVE N \\ Z -- \ DOCTOR OFFICE u EXERCISE RM. O j. 31 \ 14'x 20' n- \ \�5" 8'x 4' N \ \ WAITING AREA n O \ Q J \ 36"x96" LL- EXI5T.ELEVATOR j GLA55 DOOR? GLA55 DOOR Q COMPANY LOGO 51GN N O !L 3'G' Pocket Door`') 36"x96" 3050 PIC 30x%" O v 13' 5' 6"x%" V ------- Ln _____ `r Ln STORAGE 36"x96" N iu m _ m 6'x 10' ------- FL -----FL EXAM PM.#5 n 10,x I I' ----- X-RAY RM. EXI5TING5TORAGE 9'-7" 8'x 12' —____ 0 B h N N � m 36"x96" 36"x96" 36"x96" 7 N N CL 28"x80" m 36"x96" Z O 36"x96" EXAM RM.#4 Qz � I P x 12' _ LL- Q EXAM R.M.#I EXAM RM.#2 EXAM RM.#3 6� 9'x 14' 1 O'x 13' 1 O'x 13' Ln O � 2'-8" 2'-10" 7' 3'-2" 2'-4" 1 P-7" 3'-10" 8'-4" PERMIT SET: 22'4" 13' 13'-1 1" 8'-8" 12'-2" 6'-6" 70'_1" REVISIONS: CHECK SPIFFY• NOTE: 1.Use Lever Handles at all door hardware. 2.Com with applicable re ulations for Barrier-Free facilities includm DATE: 8/22/2015 Ma th g g� PROPOSED FLOOR PLAN NEW WALLS .Maximum threshold height to beYz"along accessible route of travel J 3.Fire Exbngwshers shall be provided per Oregon Fire Code Section 906 1 Scale: 1/4"= 1'-O" EXISTING WALLS0 A 03 I L 1/1"= 0" � F � z ® CD o n z� Q LU 1,DID� Z�� Lu 20' 46-3° 3'_2" of w N 3' 7' 6' 8' 6' 7' W 300 oLUL o - o � = d w NE 48"x 24"x 5/a' NEW 48"x 2 "x 5/a' N AM5TPO G CEILING TILES AMSTRONG CEILING TILES L (+I O'From Fmi5h Floor) (+10'From Fi 15h Floor) T 4 9 4' 5/8"GYP.BOARD-SOFFIT T9\ \ I� z _ (+9'From Fmi5h Floor) \ \ 5/a'GYP.BOARD \\ ----- ON Q (+10'From Fin15h Floor) hrO -j W A L w 1T — 4 ------ MT ----- in N NEW 48"x 24"x 5/a' , ———— AMSTRONG CEILING TILES (+I O'From Finish Floor) ----- ------- CV CV ----- 1 H N \� Ir- CO z O I W o II LL- QDF- a —61 177 ' I I'-I0" 5'-G" T 5'-G" I I'-7" " 3 " 8 8'-8 '-10 '-4" PERMIT SET: / 41'-5" /20'-10" I G-G` G2'-3" / REVISIONS: NEW 48"x 24"x 5/e" J NEW 48"x 24"x 5/a' AMSTRONG CEILING TILES AMSTRONG CEILING TILES CHECK SHEET: (+I O'From Fm15h Floor) REFLECTED CEI LING PLAN (+Io'From Fmi5h Floor) f Scale: 1/4"= 1'-0" { DATE: 8/22/2015 A 04 SCALE: 114"= P-O" EX15TING ROOF SYSTEM Z 0 O DIAGONAL BRACE Z� TWELVE GAGE HANGER TWELVE GAGE HANGER MEMM WIRE5 @ 4'O.C. W Z):�j EXISTING ROOF SYSTEM WIRES @ 4'O.C. EXISTING WALL � c� r 3s/8'25 GA.METAL STUD BRACE @ 6' N p N N O.C.-FASTEN TO TOP OF STUD WALLU Q w AND BOTTOM OF ROOF STRUCTURE EXISTING WALL = v W/METAL CLIP A5 SHOWN = f 1 f 1 m iv0 0 TWELVE GAGE HANGER WIRE5 @ 4'O.C. NEW 48"x 24"x s/g W z G"Recessed light AM5TRONG CEILING TILE5 LUw EXISTING WINDOW 9 48"x 24"x 5/8'AM5TRONG5offt ceiling () CEILING TILE5 N w Xp Countertop selected Exist.Col. — EXISTING WINDOW o w EXI5T.BALCONY by owner kLJ o o� i; N NEW PARTITION WALL TO I I' o — ST GE EXAM RM.#2 W/2"x4"STUDS @ I G"O.C. W/s/8'GYP.BD.EACH SIDE. q Cn O N EXISTING FLOORJ015T5 2' RUBBER BASE MOLDING TYP. EXISTING 15T FLOOR - NOT WORKING AREA Q EXISTING FLOOR SYSTEM W �5CALE: ITIONWALL DETAIL —id, \ma \. ,. T \y_ o112"= O" \. \ \tip . �ti� a . � . . � . a �� a\\ a\a\."\.'\n v'\. \,n\.\ .a a a SECTIOIN DETAIL 1 SCALE: 114"= 1'-O" DRYWALL GENERAL NOTES FOR X - RAY ROOM LEAD THICKNESS PER OWNER SPECIFICATIONS X-RAY room structural need to comply with requirements of the National Council on Radiation Protection and Measurement(NCRP) Installation shall be by the contractor specifically,and in strict compliance with NCRP,the radiation physicist shielding report,safety 2x WALL STUDS AT I G"O.C. codes,05HA,building code. Lead backed drywall must be installed vertically with long edges parallel to support. �'DRYWALL W/LEAD LINING Secure gypsum board to supports with fasteners spaced as recommended by board manufacturer. All penetrations in headlined wall must be properly backed with sheet lead of same thickness as on surrounding wall with proper overlaps as required. Where outlet boxes,,function boxes,ducts,conduit and similar items prevent the use of shields,provide lead sleeves or lead lining or backing as required with proper overlaps.Provide lead lining,sleeves,shields and other protections of equivalent thickness of lead Z15 used in the wall partition shielding system that each penetration occurs in. N R TYPICAL X—RAY WALL SECTION -All lead trimming must be recycled or disposed of in compliance with applicable health,safety and environmental codes and (V LJ regulations.Properly clean up and disposal or recycle all sheet lead trimming and debris.Never dispose of lead materials in general W SCALE: I /2"= I'-O" trash or refuse. H m (V N U7 p�j Ir— OTHER FIXTURES NOT ALLOWED 0 WITHIN THI5 AREA z O LU LL Q 39"-41" �: _U' (J7 Ir- 12"max 42"min �0 67 24"min 12"mm l9 E C) � x E PERMIT SET: E O l9 7 L9 E C\1 N m m E m m m REVISIONS: — m m I � CHECK SHEET: re G"max s DATE: 8/22/2015 G-2" 59"min. 17"min S TOILET CLEARANCES LAVATORY CLEARANCES GRAB BARS AT WATER CLOSETS SCALE: 1/2"= P-O" SCALE: VARIES z 0 CD o (n z w �a W c�zt� z c9 o O w = vow E FIT IT E TV W w TTcn / E tr IT LB - ----- I ----- W J / lLJ I� ----- Lty --,C o / N \ / C\jW z 0 a/- LL- ELECTRICAL .ELECTRICAL PLAN Scale:3/6'= 1'-0" Ln ELECT. AND MECH. SYMBOL LEGEND GENERAL MECH. AND ELECT. NOTES 120V DUPLEX OUTLET LOCATIONS OF DEVICES AND FIXTURES SHOWN ON THE DRAWINGS ARE APPROXIMATE.THE CONTRACTOR 15 TO SWITCHES 48"ABOVE FINISH FLOOR TELZ E EPHONE OUTLET PERMIT SET: NSTALL ALL DEVICES AND FIXTURES IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATION5.THE ELECTRICAL OUTLETS 18"ABOVE FINISH FLOOR CONTRACTOR 15 TO PROVIDE THE OWNER AND ARCHITECT A DIAGRAM SHOWING THE REVISED LOCATIONS OF ALL 48"ABOVE FINISH FLOOR(COUNTER) �} ETHERNET FIXTURES AND DEVICES PRIOR TO COMMENCEMENT OF INSTALLATION FOR REVIEW. ry TIVI OUTLET REV15ION5: TELEPHONE JACK 18"ABOVE FINISH FLOOR O 2.ALL EXTERIOR OUTLETS AND OUTLETS IN BATHROOMS AND KITCHENS AREA TO BE GFI PROTECTED. CABLE TV JACKS 18"ABOVE FINISH FLOOR � SINGLE POLE SWITCH CHECK SHEET: 3.ALL EXTERIOR OUTLETS TO BE IN WEATHERPROOF BOXES. CIRCUIT BREAKER PANEL TOP OF PANEL @ 72"ABOVE FINISH FLOOR $3 THREE WAY SWITCH 4.ALL D15HWA5HEK,REFRIGERATOR,HOT WATER HEATER AND HEATER CIRCUITS TO BE DEDICATED. ELECTRICAL METER PER UTILITY REGULATIONS FAN UNIT DATE: 8/22/2015 5.ALL DETECTORS TO BE HARD WIRED AND TO HAVE AN AUDIBLE SIGNAL