Plans BUP2015 -00243 X5 PDX RECEIVEI) AUG 13 2015 EXIT 4 cITYaFTicA>�D TENANT IMPROVEMENT BUILDING DIVISION xts Architecture a Interiors FS sr206GE x1sn1 2�9� _ 1 LINCOLN Planning Engineering RECEPTION ; a 201 °4 0,-_ xjs --" 'sP- 10300 SW GREENBURG ROAD OFFICE 9'-0„ I 5 205 CO ;gp, Portland,OR OPEICE �1 TIGARD OREGON 503.224.9560 20-2 ++eo = 7 Vancouver,WA 9'— 3 5 INDEX OF DRAWINGS 36695.7879 Seattle, WA 206.749.9993 OFFICE 9 ,SP A2.1 PARTIAL SECOND FLOOR PLAN, REFLECTED CEILING PLAN, SITE PLAN, KEY PLAN AND NOTES www.mcknze.com OPEN OFFICE .eo A8.1 DETAILS AND SCHEDULES 203l MACKENZI E. VALUATION IATION D681ON DRIVEN 1 CLIENT FOCUSED TBD Client SCOPE OF WORK 1 PARTIAL SECOND FLOOR PLAN 2 REFLECTED CEILING PLAN THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS FOR AN APPROXIMATELY 889 SQUARE FOOT EXISTING TENANT ON THE SECOND OF FIVE s x o R e s t e N A21 1/8"=1'-0 A2,1 1/8"=1'-0" FLOORS. WORK TO INCLUDE NEW WALL AND GLAZED RELITE. GENERAL NOTES LEGEND TENANT APPROVAL A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. == ===== EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING CEILING GRIDDESIGN/CODE DATA Project B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. XS PDX C. WALL THICKNESSES ARE NOMINAL, UNLESS NOTED OTHERWISE. ® EXISTING 2'x4' LIGHT FIXTURE TO REMAIN GOVERNING CODE: 2014 OSSC SUITE 290 D. SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-6"t (EXISTING) AFF, UNLESS NOTED o EXISTING WALL TO REMAIN ; OTHERWISE. ; OCCUPANCY: B :: ; EXISTING 2'x4' LIGHT FIXTURE TO BE RELOCATED TENANT E. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE EXISTING 1 HOUR RATED WALL TO REMAIN --- CONSTRUCTION TYPE: TYPE I-B IMPROVEMENT DETAILS 1/A8.1. EXISTING DEMISING WALL TO REMAIN ® NEW OR RELOCATED 2'x4' LIGHT FIXTURE TENANT AREA (APPROX): APPROX. 889 S.F. F. CENTER ALL DOWN LIGHTS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS OCCUPANCY LOAD: 9 IN CENTER PORTION OF 2x2 TILE, UNLESS NOTED OTHERWISE. ® NEW WALL TO UNDERSIDE OF GRID, SEE 3/A8.1 =z— EXISTING SUPPLY/RETURN VENT TO REMAIN 1 LINCOLN G. ELECTRICAL, DATA AND SWITCHING LOCATIONS ARE SHOWN TO CONVEY GENERAL INTENT 1 REQUIRED EXIT, 1 EXIT PROVIDED 10300 SW GREENBURG ONLY, COORDINATE ELECTRICAL/DATA/SWITCHING REQUIREMENTS WITH TENANT AND , EXISTING FLOOR MONUMENT TO BE REMOVED EXISTING SUPPLY/RETURN VENT TO BE REMOVED/RELOCATED THE EXIT IS EXISTING SUBHEADING PROVIDE DRAWINGS BY DEFERRED SUBMITTAL. " BUILDING HAS NEPA SMOKE DETECTION H. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON EXISTING SOUND SYSTEM CONTROL TO BE REMOVED a EXISTING FIRE STROBE TO REMAIN COMPLETION. CONTRACTOR IS RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON. WITH ON SITE EMERGENCY GENERATOR FOR FIRE, LIFE/SAFETY BACKUP POWER ���"" C� I. ALL INTERIOR WALLS R EX TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. A10! EXISTING OUTLET AND TELEPHONE/DATA LOCATION is?- EXISTING SOUND SYSTEM SPEAKER TO BE REMOVED DEFERRED SUBMITTAL J. OUTLETS INDICATED ARE EXISTING UNLESS NOTED.OTHERWISE. SITE VERIFICATION HAS '" BEEN PERFORMED (ON 08/04/2015, WHILE OCCUPIED) AND PLAN, ELECTRICAL AND EXISTING COVERPLATE TO REMAIN SO EXISTING SMOKE DETECTOR TO REMAIN ~ AUL CEILING INFORMATION HAS BEEN UPDATED (OBSERVATION IS LIMITED TO O 2014 OSSC SECTION 107.3.4.2 (by separate permit) VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY AND CONFIRM ADDITIONAL QA NEW OUTLET AND VOICE/DATA ROUGH IN LOCATION FIRE ALARM REQUIREMENTS WITH TENANT. EXIT REQUIRED EXIT MECHANICAL • K. NO VOC PAINT SYSTEMS T0.BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH E5 EXISTING FIRE EXTINGUISHER TO REMAIN ELECTRICAL POR PRODUCTS. EXIT ILLUMINATION q O� L. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING EXISTING LIGHT SWITCH OF TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR AND IS DEPENDANT ON NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING INFRASTRUCTURE IN EXISTING THERMOSTAT OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS CEILING. M. ALL DIMENSIONS SHOWN AS PLUS/MINUARE SCHEMATIC ONLY: THEY ARE NOT INTENDED TO REPRESENT FINAL CODE COMPLIANT MACKENZIE 2015 S (f) ARE FOR GENERAL LAYOUT AND REFERENCE DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW © ALL RIGHTS RESERVED ONLY. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF 1�` KEY NOTE FOR REFERENCE WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK. PRIOR TO SUBMITTAL THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE N. REPLACE DAMAGED AND SOILED CEILING TILES WHERE AFFECTED BY CONSTRUCTION TO EXISTING DOOR TO REMAIN USED OR REPRO WRITTEN ANY MANNER,ANE " MATCH EXISTING. xis 0. ADD SOUND INSULATION IN ALL NEW WALLS. REVISIONS: Z - .._... .........._- SW LocustStreet -'•......._. __ __._. .-.....___-_- ..........:. .___._..-_.. o' REVISIONS REVISION DELTA >W THIS SHEET CLOSING DATE K 'aO �� C p oKEYNOTES r STRUCTUtREDl PARKING t 1. REMOVE EXISTING FLOOR MONUMENT. PATCH AND AND PREP FLOOR TO RECEIVE NEW FLOOR FINISH. ttl'i 1 It frill 1l 1 2. PROVIDE NEW FLOOR TO CEILING BUTT GLAZED PANELS. ASSUME 2 EQUAL PANELS T' / P4 ( I' " �` r WITH CLEAR SILICONE CAULKING AT BUTT SEAMS, WITH BUILDING STANDARD U-CHANNEL1\\ .fti�l�;I/ 'j'j( � AT TOP AND BOTTOM. PROVIDE CLEAR STRUCTURAL CAULKING AT ADJACENT GYPSUM FOR CODE COMPLtANCB BOARD SURFACE. PROVIDE POLISHED EDGE AT EXPOSED END. SEE DETAILS, 4,5/A8.1. ,h / dy� LONGEST COMMON y - CONTRACTOR TO COORDINATE INSTALLATION METHOD AND SPECIFICATIONS FOR TENANT ✓ = �C; PATH 0 EGRESS Approvcdt liJ' F E UTA SHEET TITLE: PROVIDED LOGO AT GLAZING. 3 '- ��. �,1 - : s -a- �- �;' TRAVEL = 44'-11' � _ a �° ate' PARTIAL SECOND 3. PROVIDE BLOCKING, POWER AND DATA ROUGH IN LOCATION TO ACCOMMODATE TENANT �` — ;; _-i Z '.y. PROVIDED FLAT SCREEN TELEVISION. CONFIRM FINAL LOCATION AND INSTALLATION Permit#'. U?U6ZUI�-C >Z t. `s Address: o _ FLOOR PLAN HEIGHT WITH TENANT. ` O r ' 4. REMOVE EXISTING SOUND SYSTEM CONTROL, TYPICAL THROUGHOUT. PATCH, REPAIR AND \ k r ` fi+ C .7 � :-t Suite#: �� REFLECTED PREP WALL TO RECEIVE NEW PAINT. '" t1 -' i j CEILING PLAN, SITE 5. REMOVE EXISTING SOUND SYSTEM SPEAKERS. PROVIDE NEW CEILING TILE AS REQUIRED. (/3 ( PLAN, KEY N AND NOTES FICE COPY Ir ITI ;1 I 11 t 1.1 ��� ii 11 I I ' I DRAWN BY: KJF Ii lI t t fNif�t�l111NN1111{ .1 AREA OF WORKREDPARKINI �IucruREnPA a CHECKED BY: SBH, PDK _ G TR SWOak Streel SHEET: SE SE SE SE 4•,�—�, A2.1 25'S0" 100' 200 3 SITE PLAN &� 4 KEY PLAN A21 NTSA2.1 SECOND FLOOR NTS JOB N0. 2110955.40 TRUE PLAN NORTH NORTH PERMIT SET- 08-07-15 211095540\4-DRAWMGS\ARCHITECTURAL\40_A2.1.DWG KJF 08/06/15 09:02 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO 7/8" WALL ANGLE AT 2 BERC 2 ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 8" MAX. CLIP SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT LIMITING WALL ALL HEIGHT TABLE STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER , ATTACH STUD TRACK ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS ? INTERIOR NON STRUCTURAL NON-COMPOSITE WALLS L/240 ® 5psf \ / THROUGH GRID TO WITHIN 8" OF PERIMETER BRACE ABOVE LATERAL BRACING WITH APPROVED VERTICAL ® DESIGNATION SPACING MAX.WALL HEIGHT COMPRESSION STRUT AT 12'-0" OC EA WAY 2505125-18 24" 8'-4" SUSPENDED CLG \ �%' 8 \ /// F-,,COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB ASSEMBLY \ \ Architecture Interiors 250S125-18 16" 9'-7" "ATTACHED °°� 250S125-27 24" 9'-10" \ /� 45 Planning©Engineering WALL" °°°D 250S125-18 16" ii'-3" OO ° CUT TILE FOR TIGHT METAL STUD BRACING 362S125-18 24" 13'-5" �ZCEILJNC3 EDGE AT WALL NTS FIT AT WALLS TO FLOOR STRUCTURE AT 8'-0" CA A 3625125-18 16" 14'-4" OC W/ (2) #8 SHEET METAL NOTE: FOR UNATTACHED WALLS PROVIDE A 1/2" CASING BEAD Portland,OR TO 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP 3625162-33 16" 16'-5" USG 200—A SCREWS AT EACH END. STUD SIZING 503.224.9560 -- DO NOT SCREW BERC 2 CLIP TO TRACK 362S162-43 16" 18'-0" SOUND ATTENUATION PER SPAN TABLE. BRACING TO BE Vancouver,WAPROVIDED WHERE DISTANCE BETWEEN 360.695.7879 `� TABLE MAX. LENGTH 6005162-33 16" 24'-6" AT ALL NEW WALLS, TYP. PERPENDICULAR INTERSECTING WALLS CROSS RUNNERS FIT BETWEEN MAIN RUNNERS OR HORIZONTAL BRACING BETWEEN Seattle,WA � 1/2" DIA CONDUIT (EMT) 5'-10" 206.749.9993 MAIN RUNNERS AT 4'-0" OCINTERIOR NON STRUCTURAL NON-COMPOSITE WALLS r WALLS EXCEEDS 8'-0" OC 3/4" DIA CONDUIT EMT 7'-8" WITH CERAMIC TILE FACING ® 5psf www.mcknze.com 6'-0" MAX SUPPORT WITH #12 WIRE AT 4'-0" OC OR 1" DIA CONDUIT EMT 91-91, WITH STUDS SEE WALL HEIGHT WITH #10 WIRE AT 5'-0" OC EA WAY GYP BD EA SIDE SGL 162S125-33 MTL STUD 12'—O" TABLE FOR GAUGE AND SPACING LATERALLY BRACE MAIN RUNNER TO 1-5 8"x2OGA DESIGNATION SPACING MAX WALL HEIGHT NI AC ND E ICI Z E R CONT ACOUSTIC SEALANT DESIGN DRIVEN I CLIENT FOCUSED NOTE: STRUCTURE AT 12'-0" OC EA WAY. BACK TO BACK 1625125-33 15'-0" 362S125-18 16" 12'-4" EA SIDE AGAINST TRACK ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6'-0" OF MTL STUDS 1-5 8"x2OGA 362S125-33 16" 14'-3" I) NO SEALANT AT SIM COND Client CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER SGL 2505125-33 MTL STUD 13'-6" 1/2" MAX APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF 2-1 2"x2OGA 03 CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO BLDG BACK TO BACK 250S125-33 15'—O" WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH CONCRETE SLAB BOTTOM TRACK TO FINISH STRUCTURE. TRAPEZE DUCT WORK ,/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. I— FLOOR W/ POWDER DRIVEN WIRES TO HAVE A 200# CAPACITY. MTL STUDS (2-1/2"x20GA) 2 ANCHORS AT 4'—O" OC AND OTHER LARGE OBSTRUCTIONS � � s H o R E s T E I rt f 1 SUSPENDED CEILING BRACING z 2 WALL HEIGHT TABLE 3 NON-BEARING WALL q81 NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS v A81 q81 AT FLOOR AND SUSPENDED CEILING 3"=,'-0" 3 TITAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. ATTACH 9/16" 3625125-43 STUD BRACING Project L METAL TO "CEE" TO UNDERSIDE OF EXISTING FLOOR/ ROOF AND STRIKE X5 PDX BRAKE SHAPE W/ (2) #8 SMS AT EA END SUITE 290 \ TENANT "CE:E" 45' \ \ 45 WALL BEYOND DOOR SCHEDULE IMPROVEMENT - \ 1 LINCOLN \\ \\ DOOR DOOR DOOR FRAME HDWR \ DOOR OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH DETAILS GROUP RATING COMMENTS SUBHEADING SW GREENBURG \ TEMPERED GLAZING PER SUBHEADING \ SPECIFICATION EXIST I 3'-0"x8'-4" I EXISTING DOOR -- \ \ HARDWARE GROUPS: A� *ALL DOORS ARE EXISTING TO REMAIN NOTE, ���ti�` Cy� 1/8" BLACK NYLON PROVIDE BRACING f AT EACH END OF BOX BRUSHED ALUMINUM SPACE — CONT. HEADER, AND AT MIDSPAN CHANNEL DOOR SCHEDULE NOTES: PAUL ( UN RESILIENT SPACER A. ALL DOORS/CLOSURES TO BE CHECKED, ADJUSTED, ATTACHMENT AND/OR REPLACED TO BE IN COMPLIANCE WITH ADA. B. ALL TENANT ENTRY DOORS TO RECEIVE A NEW DOOR POR D, R ON 0 — X FLOOR FINISH WITH MORTISE LOCKSET AS DETERMINED BY LANDLORD. OF BOX HEADERW/ (2) ROOM FINISH SCHEDULE SAT CEILING ® 362T200-54 & (2) 10" STUDS, MIN 20 FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING © MACKENZIE 2015 8—6 AFF ROOM CEILING ALL RIGHTS RESERVED GAUGE NO ROOM NAME MAT'L MAT'L MAT'L MAT'L MAT'L MAT'L HT FINISH THESE DRAWINGS ARE THE PROPERTY FINISH FINISH FINISH FINISH FINISH FINISH MAT'L COMMENTS OF MACKENZIE AND ARE NOT TO BE GLAZING CHANNEL USED OR REPRODUCED IN ANY MANNER, FLOOR SYSTEM 201 RECEPTION CPT-1 RB-1 P-1 P-1 -- P-1 EXIST EXIST WITHOUT PRIOR WRITTEN PERMISSION BUTT GLAZING _ 202 OPEN OFFICE CPT-1 RB-1 -- P-1 GB/P-1 P-1 EXIST EXIST QI FI 203 OPEN OFFICE CPT-1 RB-1 GB/P-1 P-1 P-1 P-1 EXIST EXIST REVISIONS: 204 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 EXIST EXIST o 4 GLAZINCa CONCEALED HEADER o 5 RECITE SILL DETAIL AT FLOOR m 205 OFFICE CPT-1 RB—, P—, P—, P—, P—, EXIST EXIST -I REVISIONS SSfONS CLOSING L SING DATER v N 206 STORAGE CPT-1 RB-1 P-1 P-1 P-1 P-1 EXIST EXIST ro SHEET I A8.1 1 1/2"=1'-0" a 0 FINISH SCHEDULE NOTES: ABBREVIATIONS: F I A. ALL INTERIOR FINISHES BUILDING STANDARD, COLORS CPT CARPET TO BE COORDINATED WITH TENANT. EXIST EXISTING B. PATCH AND REPAIR ALL EXISTING WALLS WHERE GB GYPSUM BOARD AFFECTED BY NEW WORK. PAINT NEW AND EXISTING P PAINT �- WALLS. C. PROVIDE NEW FLOOR FINISH AND RUBBER BASE RB RUBBER BASE 4 THROUGHOUT. 1 i SHEET TITLE: SCHEDULE OF INTERIOR FINISHES AD DAILs CPT-1: TBD SCHEDULES P-1: TBD (GENERAL WALL COLOR) RB-1: TBD DRAWN BY: KJF CHECKED BY: SBH, PDK SHEET: A8.1 JOB NO.2110955.40 PERMIT SET: 08-07-15 211095540\4-DRAWINGS\ARCHITECTURAL\40-A8.1.DWG KJF 08/06/15 10:37 1:96.00