Plans (3) BUP2015 - 00138
9
„ "pw
w
�....
WIN o. .,:
RECEIVED
/ '
F MAY 1 1 2015 ,
CITY OF TIGARD
`l BUILUINC DIVISION
'
i
1,
VAA .ry i 'dux
s 'M CITY OF TIGARD
\ y, ��
Date:Approved by Plannin
g
` \
IS `
,.. �
r
Initials: m(3
77
CITY OF TIGARD
REVIEWED FOR CODE COMPLIANCE I' i R TLA N II
OTQ t l _
Permit A R C H ITE C T
MINOR REMODEL BySuite w � 711N. FIELDER
601
Date. �L �:�
fARLINGTON, TX 76012
��(/ (�' 1�, PH: (817) 635-5696
WASHINGTONSQUARE MALL OFFICE COPY j/�J` FAX: (817) 635-5699
SPACE #C06, 9681 S.W. WASHINGTON SQUARE DR. PORTLAND , OR 97223
H
SITE INFORMATION CONTRACTOR NOTE APPLICABLE CODES CODE INFORMATION DRAWING INDEX
LANDLORD: CONTRACTOR SHALL COMPLETE INSTALL PER THE SIGNED AND THE T-1 COVER afgTLANDhtGfi ;
THE MACERICH COMPANY SEALED SET OF DRAWINGS. ANY NECESSARY DEVIATIONS FROM THE BUILDING DEPARTMENT: A-1 OFFICE DEMO, FLOOR, RCP, ELEVATION& DETAIL PLAN
AARON PRATT DRAWINGS MUST BE SUBMITTED THROUGH AN RFI REQUEST PROCESS 2012 OREGON BUILDING CODE CITY OF TIGARD, OR R` RLIN�TOM,TEXAS
2012 OREGON ELECTRICAL CODE
11411 N. TATUM BLVD. WITH ENGINEERING FOR AN APPROVAL PRIOR TO CONTRACTOR 2012 OREGON PLUMBING CODE FIRE SPRINKLERED: YES
PHOENIX, AZ 85028 PROCEEDING WITH A DEVIATION OF THE SIGNED AND SEALED SET OF 2012 OREGON MECHANICAL CODE `' Q4 .
PH: 303.953.6750 DRAWINGS. 2012 OREGON FIRE CODE
CONSTRUCTION TYPE: II-B
ARCHITECT OF RECORD ALL WORK TO BE PERFORMED AT NIGHT AFTER STORE HOURS LOCAL ADOPTED AMENDMENTS OCCUPANCY CLASS: M
CORTLAND MORGAN, ARCHITECT TESLA - PORTLAND
711 NORTH FIELDER ROAD
ARLINGTON, TX 76012 TOTAL AFFECTED AREA: 170 SQFT
CONTACT: CORTLAND MORGAN DO NOT SCALE DRAWINGS PROJECT DESCRIPTION GROSS SQFT: 2,992 (NO CHANGE)
T: 817.635.5696 SPACE # C06
F:817.635.5699 CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONVERT EXISTING OWNERS LOUNGE INTO EMPLOYEE OFFICE OCCUPANT LOAD: 76 (NO CHANGE) WASHINGTON SQUARE
E: cortland c(DDcmaia.net CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ADD POWER AND DATA OUTLETS
ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING PORTLAND, OR 97223
PROJECT COORDINATOR WITH THE WORK. EXISTING SPACE IS FULLY ACCESSIBLY COMPLAINT
MSA
642 HARRISON ST . 3RD FLOOR NO STRUCTURAL, MECHANICAL, EXTERIOR WORK OR ADDITION
SAN FRANCISCO, CA 94107
T: 415.541 .0977 1 1 ISSUE / REVISION
F: 415.541 .0979VICINITY MAP SCOPE OF WORK 05/06/2015 PERMIT ISSUE
CONTACT: SHAWN ANDERSON
T: 415.852.4915
E: shawna c(Dmsasf.com
OWNER:
TESLA MOTORS, INC. " " r"" A •,;i
3500 DEER CREEK RD
PALO ALTO, CA 94304
'. 1 IW.,v jva e•c,
PHONE: 650.681.5000 20'-0•` l 20'-0° 20'-0° 20'-011
JIMMY CHAPA (E)SERVICE CORRIDOR
DESIGN MANAGER _.............-...-...._.....____ .-_.. ...._.............................
� � 23
T: 650.681.6519 I IO_ ( _
F: 650.681.5200 „P, a i„ I _. ....
E: ichapa(cMeslamotors.rom K3.. :' " u I i O SHOWROC1.1
n
DRAWING TITLE
DAVID MCVEY
gs
PROJECT MANAGER o (E)LOUNGE ......... �+ 1�>; f ;
I I I
_ .......
ix. ..
T: 650.681 5191 r \ � ..._....__........ I � , �...._....->< .._.-,
E: dmcvey(cDteslamotors.com O, (E) UNISEX s)I' jq�r : ( � '" I \� coN MALL
* O\ a TO]LET ROOM. ��.a., I IIII !i I' :I \\ \ o
rya
N",
'... j
COVER
. 3�. r � . '`::. .. •: .:' •. � • � I �N.it Jf� .� ✓,�l/`"--.......
J
' o
gg�
..>�: «,,. �:_��, ,..1_ ,( ,.i..�•-ro � I Al
TESLA MOTORS
SHOWROOM#C06 0��
(E)OFFICE I I I I I I 1
N I I. .. ......... . .................. ._.......-............ .... ......
I - - - - - -
���` I I SCALE: AS NOTED
�o ..._._.............. __......
� ,.
�� ��� �� 24 PROJECT NUMBER: 15059
AREA OF WORK BOUNDARY (E)ADJACENT TENANT
SCALE 1 = 500' SHEET NUMBER
T
N T- 1
3-5/8"METAL STUD WALL
WITH 5/8" GYPSUM ONE REUSE (E) BLIND DOOR& FRAME
S SIDE U.O.N.
BISCUIT JOINT 12"O.C.TO ATTACH DOOR
— FEATURE CEILING FRAME&MDF(TYP)
2X2 MODUCELL-COPPER 69 WATT LAY-IN (E)GYPSUM FEATURE ;
FIXTURE SAME WATTAGE AS FIXTURE CEILING & RECESSED 12'-6" 2X4 FIRE TREATED BLOCKING
REMOVED,WIRE TO SAME CIRCUIT
LIGHTING T REMAIN T O ACT
LG G O
(E) HVAC TO REMAIN (2)20g. METAL STUDS � a
lt
(E)ACOUSTICAL CEILING TO REMAIN `
REUSED BLIND DOOR&
vo
J. FRAME SEE 1,4/A -
(E)LA-142X4 MODUCELL-
12'- 10" t '• (E)C RCUIT LAE28 IRE TO O NDu
COPPER
f Ilk
26 J .f�� T.O. DOOR O &/TAPDE AT GYPSUM JOINT.
II 7, o,
w:J PROVIDE SMOOTH FINISH
A-1 OFFICE SHOWROOM m READY FOR PAINT(TYP) \
(E)ACOUSTICAL CEILING&
"` ^d LIGHTING TO REMAIN
101-91, `
Ah (E)LA-28 CEILING TILE&GRID TO 5/8"TYPE"X"GYPSUM BOARD
(TYP)
BE REPAIRED BACK TO
E FEATURE CEILING& FULL TILE AT DEMOLISHED
(E) WALL LOCATION
LIGHT FIXTURE TO REMAIN -- 0'-0"
T.O. FINISH FLOOR
(E)EM LIGHT
TO REMAIN
PT-2 4 1/4" V-1)" 3"@ DOOR 3 3°= 1'-0° BLIND DOOR HEAD/JAMB DETAI
REUSED BLIND
DOORJAMB& 1' I I R T L A N [I
HARDWARE PAINT M I] (j A N
DOOR PT-1 — — __� — _.. _ _........ 24 20g DIAGONAL METAL BRACING @ 20g DIAGONAL METAL BRACING @
ADJUSTIBLE
/ 45° BACK TO STRUCTURE, //// 45° BACK TO STRUCTURE, A I, H I T 1; T
/ ALTERNATE @ 24"O.C. ALTERNATE @ 24"O.C.
SHELFS/ STANDARDS �� W/(4)#10 EA. SIDE W/(4)#10 EA. SIDE
/ TYP. BOTH SIDES —— — —
`4 / �(E)ACOUSTICALCEILINGGRID �(E)ACOUSTICAL CEILING GRID 711 N. FIELDER RD.
/ 7 SCALE: REFLECTED CEILNG PLAN CONTINUOUS METAL TRACK CONTINUOUS METAL TRACK ARLINGTON, TX 76012
1/4"= V-0" 817
/ 20 GA METAL STUDS AT 16"O.C. 20 GA METAL STUDS AT 16"O.C. PH: ( ) 635-5696
WORK COUNTER
5/8"GYPSUM AS NOTED ON 5/A-1 5/8"GYPSUtui FAX: (817) 635-5699
&SUPORT LEGS
TYP. BOTH SIDES
\ S' CONTINUOUS METAL TRACK
ioATTACH W/#10 SMS
WALL BASE TOcn
\ MATCH EXISTING WALL BASE TO MATCH EXISTING w
o \ o (E)WALL � +
CONTINUOUS METAL TRACK W/
N \ WORK COUNTER&SUPPORT LEGS 1"SHOT PIN @ 12'O.C. Q
y WITH ADJUSTIBLE SHELF& 0'-o" O FZ CORTLAND MORGA
\ I STANDARDS ABOVE TYP (2)
T.O. FINISH FLOOR'III
FINISH FLOOR
o'-o° ICA ARLINGTON,TEXAS
OF ORS
9 SCALE: OFFICE ELEVATION OFFICE I 2 SCALE: PARTITION TYPES
TESLA - PORTLAND
i '
I
FINISH SCHEDULE I I S SPACE # C06
2^ PT-1 PAINT BM-2087-10"NEON RED" SATIN FINISH —� OFFICE CHAIR TYP OF (6) WASHINGTON SQUARE
'F OFFICE GO" MESH BLACK PORTLAND, OR 97223
OTG11657B
7B
PT-2 PAINT BM-OC-65"CHANTILLY LACE" SATIN FINISH (
23
E (E)ACOUSTICAL CEILING TO
REMAIN 2 A
t............ ISSUE / REVISION
05/06/2015 PERMIT ISSUE
(E) FEATURE CEILING TO
REMAIN p -----
LIM
SCALE:
FIXTURE PLAN -�
"" TESLA FLAG TO BE REMOVED PATCH, REPAIR& REPAINT
{ � QUAD POWER OUTLETS TO MATCH EXISTING. PROVIDE � I
CONDUIT&WIRE TO (E)225A ELECTRICAL PANEL"LA",
I UTILIZE (E)20/1 SPARE C/B 9&11 TYPICAL AS INDICATED (E) LOUNGE 1
E
S
PT-2 LOUNGE COUNTER TO BE
i ..... DEMOLISHED
(! PATCH, REPAIR& `: 3-5/8" METAL STUD WALL \' .
REPAINT TESLA FLAG (E)LA 12 11'-7" WITH 5/8"GYPSUM ONE
LOCATION BOTH SIDES I "' SIDE U.O.N. (E)CARPET TO REMAIN
I ..._....._.................
I
-"' r, REUSED BLIND DOOR,
FRAME &HARDWARE SEE ° I
I 7 0 REUSED BLIND DOOR, 0 U ® A A 1,4/A-1 (E) UNISEX 0 (E) DOOR& FRAMED TO BE
FRAME& HARDWARE SEE 1, LA-9 (N) (— (N)4 (E) —(— —(— — REMOVED AND SAVED FOR
\ 4/A-1, PAINT DOOR PT-1 REUSE. PATCH REPAIR&
DRAWING TITLE
\ a I REPAINT AT WALL&JAMB
\ I GYPSUM BOTH SIDES THIS (E)WALL TO BE DEMOLISHED
\ OFFICE LOCATION — I SEE 3/A-1
3 \
OFFICE
OFFICE DEMO
A-1 9
FLOOR RCP
O ..;...... (E)TILE TO REMAIN
, s
ELEVATION &
/• � I 2A ' (E)COUNTER&CASEWORK
I / WALL BASE TO A 1 I N Z \ ( r TO BE DEMOLISHED
�" ""' DETAIL PLAN
/ MATCH EXISTING
I (E)WALL GRAPHIC TO BE
/ DATA OUTLET TO MATCH DEMOLISHED
I (E)W/2 OR 4 CAT6 WIRES
/ TO(E)RACK IN IT CLOSET
TYPICAL AS INDICATED — — — — — — — — — — — — — — -=---- ----- PATCHTESLA, REPAIR& REPAILAG TO BE NT 4- - - - - - -
E (N) (N)2 (N)4 (E) (E)2 (E) IN SCALE: AS NOTED
/ 1 qp v v PROJECT NUMBER: 15059
I FINISH FLOOR
zA SHEET NUMBER
A-1
PATCH & REPAIR ALL WALL
SURFACES&PAINT PT-2 U.O.N.
SCALE: SCALE: SCALE: A 1
S 1/2" SHOWROOM ELEVATION cJ 1/4" FLOOR / ELECTRICAL PLAN 1/4" = 1' (E) CONDITIONS & DEMOLITICN PLAN