Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
BUP2015 00067 01 00 00 GENERAL DATA 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 23 00 00 HVAC : DESIGN/BUILD OFFICE LIGHTING GENERAL REQUIREMENTS PSI)G60. HVAC-BID PROCEDURE 1. OFFICE LIGHT FIXTURES- LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN BALLASTS) 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON AN APPROVED EQUAL.C-36. 1. y� STRUCTURAL SPECIALTY CODE, AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. 5PROPER WORKING ORDER. 28 30 00 ELECTRONIC DETECTION AND ALARM TENANT IMPROVEMENT �Ol #3082 . STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH GENERAL MARTIN W. HANSON � NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. UNIT FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR"SPECTRALERT ADVANCE DEVISES,OR APPROVED EQUAL. 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 3. LIST TONNAGE OF EACH UNIT. CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED C-630. `f 1 HVAC-DESIGN PROCEDURE INSU-zUNCjffuL1 � CLA KAM S, OREGONCONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. CNA �THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDSf 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) LISTED BELOW. V� & EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD Y:"THICK WITH SQUARE,REINFORCED, PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FORCOMPANY' MAR 1 9 2015 e ful,W 010DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 9, AT FRP,PLASTIC LAMINATE,ETC.,WAINSCOT PANELING INSTALL WATER-RESISTANT GYPSUM BOARD. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE INCLUDE THE FOLLOWING: CffY OH1GAi(l) : PROJECT #15180 SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. a. DUCTING AND SIZES BUILDING DIVISION`�ISIOI'. 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH B p, STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS SYSTEM. b. SUPPLY AND RETURN LOCATIONS AND CFM PROJECT NARRATIVE INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. WALL CONSTRUCTION EXECUTION c. ROOF EQUIPMENT,SIZES AND LOCATIONS �( 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. d. UNITS REQUIRING DUCTED SMOKE DETECTION PROJECT CONSISTS OF TENANT IMPROVEMENT WORK WITHIN 14,896 RENTABLE SF OF C.)1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING EXISTING OFFICE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO SELECTIVE v 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH DEMOLITION, DRYWALL/METAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES, FINISH W CARPETS. CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF MATERIALS LIGHTER THAN 18 GA. WORK AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. E* MEMBRANE AS NEEDED. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 9• ZONE DIAGRAM ISI 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. HVAC DESIGN STANDARDS I= COMPANIES INCLUDE: FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT �) 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION a. ARROW ROOFING, ALFONSO PEREZ 503 1. 350 SQUARE FOOT PER TON. PLUMBING WORK 9( )460-2767 STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT b. PACIFIC ROOFING, GUY BELT (503)640-3163 LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY FIRE PROTECTION SPRINKLERING c. GRIFFITH ROOFING, GREG STONE (503)643-1596 JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE TENANT PRIOR TO CONSTRUCTION: HEATING, VENTILATION &AIR CONDITIONING WORK STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP a. EXTERIOR EXPOSURE AREAS ELECTRICAL WORK-LINE VOLTAGE n 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS, b. INTERIOR AREAS,SIZE AND USE ELECTRICAL WORK- LOW VOLTAGE(BY TENANT) Z AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO THE PROJECT. c. CONFERENCE/TRAINING ROOMS O O COMMON CORRIDORS AND STAIRS, BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION lt BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION AND 24-HOUR USE. BUILDING INFORMATION TENANT INFORMATION Z ACTIVITIES. 6. FINISH QUALITY: 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING AREA PROCESS TRADE NOMENCLATURE 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: �I PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. ��44 RESTROOM FACILITIES. 15350 SW SEQUOIA PKWY#300 CNA INSURANCE COMPANY OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE = a N 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT ZONES. PORTLAND, ORE 97224 USG"FIRST COAT" SAND AFTER TAPE/FINISH COAT(S) N OCCUPANCY AREAS& LOADS: � PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. r-i r-- COMMON BUILDING AREA BE USED FOR STORAGE. 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS O" (503)624-6300 (PHONE) USABLE 13,482 SF 135 OCC p O vn 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. SHOWN ON PLANS. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. P4 O u7 (503)624-7755(FAX) RENTABLE 14,896 SF m r 09 53 00 SUSPENDED ACOUSTICAL CEILING 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 a �p r 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. Zj TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. W 44 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE BLDG. #: BLDG. B (ppC082) NUMBER OF EXITS REQUIRED I * C/1 Q N N ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. � �111 CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. B 2 EXITS ��/ 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 3. BENT OR DAMAGED T-BARS TO BE REPLACED. 8. ECONOMIZER TO MEET CODE AND AS FOLLOWS: CONST. TYPE.: II-B 3 PROVIDED Fil �� O o 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE �I O E-i kV ACCEPTABLE. a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. -!VV 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. THIS BUILDING HOUSES MULTIPLE TENANTS INCLUDING THIS TENANT. THE EXISTING cn 09 65 19 RESILIENT FLOORING -VINYL COMPOSITION TILE b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. w') O x 20.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. BUILDING IS A FOUR STORY BUILDING OF 87,890 SF AND IS FULLY SPRINKLERED. EACH .-� f1, a w DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 1. EXTEND FINISH FLOORING UNDER CASEWORK. FLOOR IS LESS THAN 23,000 SF ALLOWING FOR NON SEPERATED USE. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 2. INSTALL TILES IN QUARTER TURN PATTERN. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. , SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 9. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED 09 91 23 PAINTING AND APPROVED. INTERIOR: 10.DISTRIBUTION DUCTWORK: 21.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, a. SPIRAL ONLY IF EXPOSED. ■ FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 1• WALLS: r TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. WHETHER OR NOT SHOWN ON THE DRAWINGS. 11 b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH MINIMUM R 22.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. INSULATION WITH FSK BARRIER. W 23."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 2. DOORS AND FRAMES: d. HANGERS 122 GAUGE WIRE TE 1 S GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. HANGERS AND FULL DIAMETER STRAP UP TO 18"H. LARGER THAN 18"MUST HAVE SADDLE TYPE11 a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. CLAMP. O 24.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. b. EXISTING HOLLOW METAL-SAND, FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 25.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. DEGREES. It TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TOn1 c. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND, FILL ALL FASTENING HOLES WITH f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. 00 REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL r REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX g, ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS CAULK,AND FINISH WITH SATIN OIL ENAMEL. $m� DIRECTED AT CONTRACTOR'S COST. d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SATIN OIL 11.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. P (- ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,AND RE-VARNISH WITH SATIN 12.DIFFUSERS: 26.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND PROJECT LOCATION PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL VARNISH. a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN ` __j (� SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 3. CEILINGS: TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. � \ 5•I�. HAh'IFTON 5TREE T COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN C -- 27.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. Q EE CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE � I I I I 1 �a-. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE WITH MILLER'S 6200 OR 4480. WYE BRANCH. Q CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE 4. GENERAL NOTES: d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT 1 � (� APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY COMPLETION. T 0� W � \ 4 9P �0 9 I a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER zr THE ARCHITECT PRIOR TO INSTALLATION. SPRAY. 13.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE y�a i, � 28.000RDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB822OU1003 WHERE POSSIBLE. INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. r q I y APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY ro � c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY I � GENERAL RAGS AT THE END OF EACH DAY. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM P11 I-cj 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING THERMOSTATS AND BALANCE SYSTEM. D TO INSTALLATION OF NEW FLOORING. AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. 14.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. `n s 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH I s A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 e. PROTECT WORK OF OTHER TRADES. 15.EXHAUST FANS: 1 ,ii S POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT / 08 10 00 DOORS AND WINDOWS 10 00 00 SPECIALTIES CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. L _ COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A I I I m 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 10 28 13 BREAK COUNTER SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. � I I I 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. a. BAXTER AND FLAMING. (503)225-0486 2. CUP DISPENSER-BOBRICK B-235 c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE \JT77TFFUTFFF7 b. D&D DOOR (503)205-5533 10 44 16 FIRE EXTINGUISHERS ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, r Tc. BENSON INDUSTRIES (503)907-2200 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED ORIN SEMI RECESSED CABINET AS INDICATED ON PLAN) CONTROLS AS REQUIRED BY DESIGN.COOK ACE-D SERIES OR EQUAL. ttf I 4 d. GRANT SUPPLY (360)887-0647 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- I I > INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE v 3. DOOR AND RELITE FRAMES SHALL BE TIMELY II,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING 11 00 00 EQUIPMENT OF A ROOFTOP MOUNTED FAN. I I MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 1. DISHWASHER: GE GLDA690FWW WHITE,OR EQUAL APPROVED BY PACTRUST. 16.HVAC TESTING. F------�F-----�F-------� 4. EXTERIOR DOORS AND FRAMES TO BE HOLLOW METAL. FRAMES OF ONE-PIECE WELDED CONSTRUCTION, 14-GA.GALV.SHEET STEEL. DOORS,SDI-100,GRADE II,SEAMLESS EDGES, 16 GA.GALV.SHEET STEEL. 12 00 00 FURNISHINGS a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,FABRICATE DOORS AND FRAMES WITH HARDWARE REINFORCING WELDED IN PLACE. 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. N 5. FIELD VERIFY EXISTING DOOR, FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 12 23 16 CABINET SPECIFICATIONS b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN 1 LOCATION MAP FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. A-1 NOT TO SCALE 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND W O 7 .DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. FILED WITH PACTRUST. 3. .HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES,INCLUDING 4"TOE KICK. EDGE BANDING E'-'' ON 8. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. (MATCHING PVC ACCEPTABLE),FIN ENDS, DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS 17.PROJECT CLOSE OUT DOCUMENTS REQUIRED: 9. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. W . HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH MELAMINE FINISH. U >-+ m APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. AREA OF WORK c11 SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER ,7' N c. HARD COPY OF AutoCAD FILE ABOVE. � � 1 PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR a SAMPLE. PVC EDGES. d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. �, " I'll . i-, 4 x 10.ALL INTERIOR GLAZING SHALL BE TEMPERED. 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. 0 In,11.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. 26 00 00 ELECTRICAL : DESIGN/BUILD Q CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH 8. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CLIP ON(OR EQUAL). GENERAL O � a Z WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. w 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. � _ _ ,` U � 12.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. -- �I W �w 0 FINISH FOR AS NEW LOOK. 11 10.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING ," U O p,/ 13.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. p, UQ�' N 09 00 00 FINISHES 11.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. a a SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. F GENERAL CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. ACCOMMODATE PTO BE SEALED. INUMIBERSZE O INK CLAMPS CLUNTERTOP DEARANCEUPS AT FRONTRND BACK OF SINK CUT OUT TO 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER REVISION V iS1OlV 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 12.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO a. FLOOR COVERINGS AND BASE SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12"D X 36"H-ATTACH TO WALL TENANT'S MOVE-IN. b. PLASTIC LAMINATES WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 26"D. MICROWAVE SHELF 18"D WITH 3"RADIUS OUTSIDE 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO 1-FOOT 1• CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJ.HOLES AND POSTS(1 AT BASE,2 AT UPPERS). CANDLE. c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 21 00 00 FIRE SUPPRESSION : DESIGN / BUILD 6. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, 2 BUILDING PLAN - SECOND FLOOR Z 2. d. PAINT WITH BATTERY BACKUP. A-1 1. ADJUST SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2 X SCALE V =50' 3 e. TILE,MARBLE,GRANITE,STONE,AND GROUT 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD CEILING AREAS 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE f. TOILET PARTITIONS (GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. g. HARDWARE 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. a. TRANSFORMERS TO BE ENERGY STAR LABELED. 4' NO"OOPS RINGS ALLOWED". b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. _ Cr"Qr TIGA" 5, 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK. 3. PROVIDE AUTOMATIC FIRE SPRINKLER FLOW INDICATOR SIEMENS CU-MHU-MCS-W OR EQUAL.SEE PLAN FOR c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C REVIEWED FOR CODE CU112PI,YANG"$ 09 21 00 GYPSUM BOARD LOCATIONS. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS 6. GENERAL 22 00 00 PLUMBING OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM Appmvc4 I 1 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24" SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL OTC: 7 O.C.WITH GENERAL REQUIREMENTS ASSEMBLY AND CASE. �� /� 1"TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN 9. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCE:3S BELOW FLOOR,USE WIREMOLD RC7 Permit#S .,► ,�()I +"� 8. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. FLUSH POKE-THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO 45511,2 AT EACH r . ,�„ ' FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF LOCATION TO SEPARATE POWER AND DATA WITH 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. Adilre$Ss ��' 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH RESTROOMS. LOCATE VALVE BEHIND HANDICAP TOILET IN MEN'S RESTROOM. 10.TELECOMMUNICATION SYSTEM BY FUTURE TENANT. COAT. PAINT AS INDICATED. SU* DRAWN BY: 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE 11.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. \ ■*�.r Ft�5- 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER INSULATED. S Dater R.M.T. AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN 12.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. y` L WITH 1"TYPE S DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT CITY OF TIGAkD AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD LOCATION. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND 4 , DATE: 2/27/15 SPACING),EACH SIDE AND OPPOSITE SIDES. 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THAY OPERATE Approved by Planning PERMIT SET 5. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. f� �+ OFFICE COPY METAL STUDS. AVAILABILITY,(503)236-4148. 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. Date: _ �" J ,� 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 �� 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. 15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA OR MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR Initials: . 7. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND DRAIN. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. PATCH HOLES READY FOR PAINT. .16REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS APPROVED BY OWNER. PROVIDE A MIN.OF 12" OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING WALL CONSTRUCTION MATERIALS ACCESS DOOR. 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE PLUMBING-BREAK ROOM FIXTURES IIIIIIIIIIIIIIIIIIIII INSTALLATION. 1. BREAK ROOM SINK ELKAY GECR2521 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 2. KITCHEN FAUCET DELTA 100-DST PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 3. 1/4"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REF.,SEPARATE LINES IF REQUIRED. BUILDING DEPARTMENT USE -� �4 . (2) 3 3.7) ".? _ 10) 11 (12) #3082 5 6 � 7 � 8 , � 9 ) �,9.3� l MARTIN W. HANSON 1� �CLA KAM S, OREGON --__ _- - - _ _ N OF i j PROJECT #15180 ft 11 1 L___; VENDING Ix lo- CONFERENCEI BREAK h•+� 217 I I 216 i ® c=_ITER IN R00 -�1V�REF, g O O "i��� A G o 2i x28- 45'MICRO. 45• 45' x FILES �� o15tiwASUER d O N-LP N-V -1 213 v -j_ �t N - - � 4 -- � 1 = I 215 CIRC. � 0 Q �� 214 F * OE 00 kn N Ix kn TRAINING M FR RELOCATEGARD 6 0 i READERS 213E ✓GT-i O J O ! O O O _ A �L IL f Z MM N AT N CO U IC 10 S _ q W i 209 � �i III qp �I CARD I'I u READER FER ! O I ! i LE , lull CARD &q Qp CONF -� 00 N I MAIL I 0 G 771 O O � , I �, M C o i HP STIOR I ;X : CARD 208 �i CARD R ADER � ���—-� �- d I w,j uii EADER CARD Rry ER CARD w w; READER \ ~ = C C=o-o. READER = C STOP. UTILITY RECEPTION CLOS. 203 i ® ® ® 202 201 205® ® ® OPEN OFFICE ® 206 Q � I CARD READER -- _v h _ / D CARD FER READER T OPEN OFFICE I 204 I i CONF. AV MGR. ® V 210 _ _ -� C� - _ o ��) O a `° z AREA OF WORK w 3 U UC\ w' 1 PARTITION AND POWER PLAN A-2 SCALE 1/8"= 1'-0" z REVISION 1. 2. ------- - FINISH MATERIALS ABBREVIATIONS 3• DOOR SCHEDULE ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. CR CHAIR RAIL 4. - CARPET LOOP PILE: E EXISTING j DOOR DATA FRAME DATA__ TA HARDWARE LP PATCRAFT.DESIGNWEAVE,26470-LUXURIOUS EBL!00589-MAJESTIC. ETR EXTEND TO ROOF 5 Fire Rating Remarks 34 OZ.TUFTED YARN WEIGHT(CNA Corporate Account Rep is Megan Williams. GWB GYPSUM WALL BAORD -- - Type p Hardware Manufacturer ,Finish Function 312-805-5512) HM HOLLOW METAL 6, Mark I Door Size Thk Core Veneer Finish .Hand T e !Frame Depth � vINYLcoMPos171oNTILE N NEW CONSTRUCTION LEGEND 213 3 0 x 9 0 1 3/4 SC SAPELE CHERRY Left • TIMELY 4 7/8 LEVER/LOCK/CLOSER (D SERIES) SCHALGE 905 POLISHED BRASS D80PDEU RELOCATED DOOR AND FRAME VCT-1 ARMSTRONG EXCELON,STONETEX,#52143 SANDSTONE TAN,12"x 12"x 1/8" PGWB PAINTED GYPSUM WALL BOARD 7. - ( ) AL1 OS '2 X 9 SIDELITE VCT-2 ARMSTRONG STATIC DISSIPATIVE,#51950 MARBLE BEIGE,12"x 12"x i/&' PL-# PLASTIC LAMINATE 1215 3'-0"x 9'-0" 1 3/4" SC SAPELE CHERRY Left • TIMELY 4 7/8" LEVER LATCH AL SERIES SCHALGE 905 POLISHED BRASS 216 3'-0"x 9'-0" 1 3/4" SC SAPELE CHERRY Right • TIMELY l 4 7/8" LEVER/CLOSER (D SERIES) !SCHALGE 905 POLISHED BRASS !ND10S 1 X 9 SIDELITE BASE PT-# PAINT 0 EXISTING TO REMAIN g RF R PP d"FLATRUBBERBA P1 BURNT UMBER, P T R 217 3-0'x 9-0 1 3/4 SC SAPELE CHERRY Right • TIMELY 4 7/8 LEVER LATCH (AL SERIES) I SCHALGE 905 POLISHED BRASS !AL1 OS !2 X 9 SIDELITE _g._ E RUB SE, 94 8U N U BE ALL CARE A EAs. RC RUBBER BASE COVED o EXISTING TO BE REMOVED -- - - RC ROPPE 4"COVE RUBBER BASE,P194 BURNT UMBER AT ALL HARD SURFACES. RF RUBBER BASE FLAT I - _ .. ....... . _.... .... PAINT: SAT SUSPENDED ACOUSTICAL TILE ® n�a NEW STANDARD WALL DRAWN BY: FINISH c V C H E D U L E PT-1 MILLER 4480 PREMIUM SATIN-COLOR MATCH BENJAMIN MOORE,#1059-113 MOCCASIN,SATIN SC SEALED CONCRETE R.M.T. �— LATEX. SV SHEET VINYL NEW STANDARD WALL WITH INS. — - .. ....... CLG. WALL COVER TCP TEXTURED CUT PILE (LANDLORD) --- NEW STANDARD WALL TO STRUCTURE ABOVE WITH INS. DATE. 2/27/15 RM#!NAME FLOOR BASE I J CEILING REMARKS WC-1 D.L._C000H,MAROUES5'A,L2-MG-OS BEACHSAND(CNA Corporate Account Rep IS Celine Ehlers. VCT VINYL COMPOSITION TILE WALLS NORTH EAST SOUTH WEST HT. 312 467-0780 or 312-420-1242 WBC WALL BOARD CEILING PERMIT SET 214 CIRC. LP 4" RF PGWB PGWB PGWB PGWB E-SAT 8'-6" -- LAMINATE: WC WALL COVER DUPLEX RECEPTACLE ELECTRICAL PANEL - - - PL-1 WILSONART,#D50.60 KHAKI BROWN,AT ALL FACES 215 TRAINING LP 4" RF WC-1 /E- GWB/WW WC-1 /E-GWB WC-1 /GWB WC-1 /GWB E-SAT 8'-6" -- PL-2 WILSONART,44550-01 GRANITE,B.S.AND SELF-EDGE. WD WOOD FOURPLEX RECEPTACLE OJ POWER J-BOX - - -- CAB PULLS 605 POLISHED BRASS WOC WALK OFF CARPET 216 BREAK VCT-1 4" RC WC-1 /E- GWB/WW WC-1 /GWB WC-1 /GWB WC-1 /E- GWB/WW E-SAT 8'-6" D� 217 1CONFERENCE LP 4" RF WC-1 /GWB WC-1 /GWB WW WINDOW WALL WC-1 /GWB WC-1 /E- GWB/WW E-SAT 8'-6" -- CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 6v EXISTING ELECTRICAL TO REMAIN FER FIRE EXTINGUISHER IN RECESSED CAB. FLOOR MONUMENT W/SERVICES SHOWN FEs FIRE EXTINGUISHER-SURFACE MOUNTED — SPECIAL OUTLET THERMOSTAT TEL/DATA MUD RING WITH PULL STRING Oi3o8z r # - j 1 MARTIN W. HANSON � CLA K S, OREGON,y OF O=II o• I \ I I�II I iI!II�i! o=IIiiII.Ii OO ICE - _ —II!!IIIII!II � iIIiIIIIIII'IIIII FILI -� ����`II FUI es�-��1I1i��®0m'�J�..1II •O2 zISI —_--- )\J i ' P1'R �l��TFZH�wv owSj/O�I JE WCooMOd��M��T �z 1 5azw 1�O (Qll) O� O O O O �N�MOOM� rT OZ OZ ZO ji � —�8NxoI oaE - EL M E00Q' 44— r I rE imi z AREA OF WORK U V o 04 b� " un REFLECTED CEILING PLAN REVISION SCALE 1/8"= F-0" INDICATES COMMON PATH OF TRAVEL REQUIRING EMERGENCY LIGHTING EQUAL TO 1-FOOT CANDLE. 2. 3. 4. 5. 6. 7. 8. DRAWN BY: CEILING LEGEND R.M.T. 2 X 4 FLUOR.T-8 3 TUBE FIXTURE SUPPLY DIFFUSER DATE: 2/27/15 PARABOLICLENS RR RETURN DUCT PERMIT SET 2 X 4 FLUOR.FIXTURE 4L 4 4E io PARABOLIC LENS/STEADY BURN BALLIST EXHAUSTFAN LRECESSED LED DOWN LIGHT(TYP.) TIE SPRINKLER HEAD >< $ STANDARD SWITCH e EXIT SIGN(LED RED) ® OCCUPANCY SWITCH llI s HORN/STROBE FIRE ALARM(WALL MOUNT) CEILING OCCUPANCY SENSOR (U Ns 1)) HORN/STROBE FIRE ALARM(CEILING MOUNT) 0 SMOKE DETECTOR 1' 32' 32' 32' 32' 32' #3082 10 GA 3 5/8'METAL STUD BRACING MARTIN W. HANSON TO ROOF STRUCTURE AT 10'-0' OC WHERE REQUIRED ADJ.S ELF ` �_ _ — _` ADJ.S ELF ` ' _ — ` ADJ.S ELF aCLA KAM S, OREGON ROOF DECK - '--EXISTING SUSPENDED CEILING OR BEAM ADJ.EWELF ADJ.EWELF OF RACO STYLE RECESSED RACO STYLE REVEAL HEADER ` RECESSED REVEAL CONCEPT WALLS M-481RDT � HEADER CONCEPTSUSPENDED GLG ASSEMBLY PROJECT #151$0 WALLS �1-481RDT PROVIDE PADISPENSER PL-1 _ 1 F 3.5/8'MTL.STUDS 9 14' O.C. H I 45?. Q © o 0 0 5/8'GYP.BRD.BOTH 51DE5 a W 9 CENTER LINE OF STUD 11/2' [moi 20 GA 3 5/8" METAL STUD BRACING BACK 5PLASH 'v hal TO ROOF STRUCTURE AT 10'-0' OC Wl (2) *8 SHEET METAL SCREWS AT EACH END. BRACING ' ( ' ADA SINK ` I I I TO� BE PROVIDED WHERE DISTANCE r ADJ.IWELF ADJ. NELF ADJ.SHELF 'v .� BETWEEN PERPENDICULAR INTERSECTING = _ — — = DW '^ 4' RUBBER BASE-TYP. WALLS OR HORIZONTAL BRACING _ _ _ _ _ _ _ _ _ _ _ _ _ i ATTACH BOTTOM TRACK TO FLOOR WITH BETWEEN WALLS EXCEEDS 12'-0" OC POWDER DRIVEN ANCHORS AT 12'0r-, .` / p FINISH FLOOR P-LAM BASE OPEN BASE P-LAM BASE 8 I di- 34' I 34' I 14' 34' 34' I y' 4 l/ 1 TYPICAL WALL SECTION r5 WALL BRACING DETAIL 9 CABINET ELEVATION 216 BREAK A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = i'-0" A-4 SCALE 1/2"= P-0" N . Q� 0� Z cy m c� �Z wa 20 GA 3 5/8'METAL STUD BRACING O H o O TO ROOF STRUCTURE AT 10'-O'OC WHERE REQUIRED O R-11 BATT INSULATION 4'CENTERED OVER WALL N x TYPICAL STUD EXISTING SUSPENDED CEILING RACO STYLE RECESSED REVEAL HEADER CONCEPT WALLS *1-481RDT �.. P' ANGIOR5 TRACK 3-1/2' BATT INSUL. W INSTALL STUDS WITH SAME 3-5/8'MTL.STUDS 9 24'O.C. DIMENSION (10' MIN.)FOR 5/8'GYP.BIRD.BOTH SIDES BRIDGING ALIGNMENT CENTER UNE OF STUD Q aP N 00 Q O U IVEN 3-1/2' BATT INSUL. IN SOUND ATTENUATION WALLS T 12' O.G. G� YJ 4'RUBBER BASE-TYP. - EW ATTACH BOTTOM TRACK TOFLOOR WITH PER STUD FLANGE POWDER DRIVEN ANCHORS AT 12'O.C. A FINISH FLOOR 141/81 2 WALL SECTION W/ SOUND INSUL WALL BASE DETAIL Q A-4 SCALE 1"= 1f-0„ A-4 SCALE 3" = 1'-0" Q BLDG S-R;;CTURE ABOVE Ld CAU K:\r !N ':t2' SaATE 3-1/2' BATT !\SUL. — EXISTING WINDOW WALL MULLION I SUSFEN-_ED CEILING ACTUAL SHAPE AND SIZE MAY VARY CENTER L v=_ OF STUD FROM EXTRUSION SHOWN I 3 5t8' MTL.STUDS Io' C.G. EXISTING GLAZING O\= LAYER 5,'8' TYPE X GYPSUM WALLBO-:zD AT R'S-WT ANGLES OR - I PARALLEL TO EACW!S`DE OF METAL -- STUDSOSU;7141 TYRE S DRYWALL I SCF W5, E$ CL. TO VERTICAL EDGES AD i2' OC. TOP D BOTTOM 3!'6" x i' BLACK FOAM INSULATION TAPE s, NO AN R,'N\ERS AtiD NTER"!EDIATE STUDS, STAGER ALL VERTiCAL AND AOS OFFEJOINTS- 2A' G.C.EACH SIDE RACO STYLE RECESSED REVEAL E-, o AND GP=OS = S-DES. -• I TRACK,CONCEPT WALLS '1-451RDT W C _ I CENTER ON WINDOW MULLION AND E SECURED BY GYP BOARD.NO 5CREW5 IN N WINDOW WALL SYSTEM ALLOWED - A-, 4 RiBEER BASE TYR. I EXISTING WINDOW SILL x C) ATTACa B^:TOM TRACK TO FLOOR WITHH POW^ER Dom',✓EN ANCHORS AT 12' O.C. i WALL STUD FLUSH WITH WINDOW SILL O ��1 I, a \ �y CARPET AND PAD SMOOTH FIN.GYP BD. OVER METAL STUDS "1 FiN!S I FLOG: TCR OF SLAB W' U0-4 - 4 3 ONE HOUR WALL SECTION W/ INS. 7 WINDOW CLOSURE AT MULLION A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = 1'-0" V1 p., --" P-4 REVISION 1_ 1. 2. 3. 4. LITE KIT U)"ERE SPECIFIED d La i 5. 7. 0 8 - p—_ u � O ADD.T ONAL SWITCH w w ` U �GG\! LCCATICN ff r( !LTJI DRAWN BY: z - - R.M.T. - DATE: 2/27/15 PERMIT SET ELECTRIGAL _ Q wCUTL=r w ' \ OR BOX LLIp O z OLL_ Ok UNDERCUT DOOR A5 REQUIRED TO GLEAR co v o FLOOR FINISH 4 MOUNTING HEIGHTS -4 SCALE 1/2" = 1'-011