Loading...
Plans BUP2014 00238 RENEWABLE Ener OCT 15 2014 gy Associates 72ND TIGARD , 72 . 6kW SOLAR ELECTRIC SYSTEM CIT`19T a UILD ,? iIsIPO Box 208 Corvallis, OR 97339 541.754.2001 office/fax 13535 SW 72ND AVE , TIGARD , OR 97223 STAMP: ABBREVIATIONS SCOPE OF WORK GENERAL NOTES TYP TYPICAL UL UNDERWRITERS LABORATORIES THE PROJECT SCOPE INCLUDES THE INSTALLATION OF 63000WAC RATED GRID-TIED ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDEP THE DIRECT SUPERVISION OF THE LICENSED CONTRACTOR. PV PHOTOVOLTAIC IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS TSRF TOTAL SOLAR RESOURCE FACTOR IBC INTERNATIONAL BUILDING CODE SOLAR PHOTOVOLTAIC SYSTEM AT THE 72ND TIGARD COMMERCIAL BUILDING IN TIGARD TOF TILT AND ORIENTATION FACTOR NEC NATIONAL ELECTRICAL CODE OR. ALL SOLAR MODULES SHALL BE UL LISTED 1703 & CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741 CERTIFIED & CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS DC DIRECT CURRENT SHALL BE LISTED FOR IT'S PURPOSE AND AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. AC ALTERNATING CURRENT THE INSTALLATION CONSISTS OF A ROOFTOP SOLAR ARRAY, THREE INVERTERS, AND A AMPS RELATED ELECTRICAL METERING AND SAFETY EQUIPMENT. ALL EQUIPMENT WILL BE ALL FABRICATION AND MANUFACTURING SHALL BE PERFORMED BY CERTIFIED INDIVIDUALS IN APPROVED ASSEMBLY AND FABRICATION SHOPS. V VOLTS INSTALLED AS REQUIRED BY APPLICABLE CODES AND THE LOCAL UTILITY COMPANY. W WATTS PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES NOTED AMONG SITE CONDITIONS, MANUFACTURER WDC WATTS OF DIRECT CURRENT DURING DAYLIGHT HOURS THIS PHOTOVOLTAIC SYSTEM (SOLAR ELECTRIC) WILL RECOMMENDATIONS, OR AUTHORITY HAVING JURISDICTION. WAC WATTS OF ALTERNATING CURRENT PROVIDE ELECTRICITY IN PARALLEL WITH THE LOCAL UTILITY SERVICE PROVIDER. CU COPPER CONDUCTOR AL ALUMINUM CONDUCTOR CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER IN THE FORM OF A "RFI", REQUEST FOR INFORMATION, PRIOR TO MAKING ANY CHANGES. APPROVED SYSTEM DESCRIPTION CHANGES SHALL REQUIRE A DRAWING REVISION TO MAINTAIN CONTROL OVER THE ENGINEER APPROVED DESIGN. SYMBOL KEY (242) RENESOLA JC300M-24Ab, 300 WSOLAR MODULES THE ELECTRICAL CONTRACTOR IS ADVISED THAT ALL DRAWINGS AND COMPONENT MANUALS ARE TO BE UNDERSTOOD PRIOR TO INSTALLATION. THE CONTRACTOR IS ADVISED TO HAVE ALL VIEW NUMBER \ (2) ADVANCED ENERGY AE 3TL-20 INVERTER(S) SWITCHES IN THE "OFF" POSITION AND FUSES REMOVED PRIOR TO INSTALLATION OF FUSE-BEARING COMPONENTS.(1)A ® y ELECTRICAL DISCONNECT SWITCH ADVANCED ENERGY AE3TL-23 INVERTER X (1)ADWATTS DC THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL 1741 AND IS INTENDED TO SECTION CALLOUT PREVENT THE OPERATION OF THE PV SYSTEM WHEN THE UTILITY GRID IS NOT OPERATIONAL. X ELECTRICAL FUSE 63,000 WATTS AC SHEET NUMBER ADVANCED ENERGY INVERTER VOLTAGE AND PHASE: 480V, 3�) PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS ARE OBTAINED FROM THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL ELECTRICAL BREAKER APPLICABLE CODES UTILITY SERVICE PROVIDER. DETAIL CALLOUT X REVISION NUMBER THE METHOD OF ATTACHMENT CREATES A UNIFIED STRUCTURE TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. SOLAR MODULES WILL BE SECURED TO THE EXISTING INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PV SYSTEM. OREGON STRUCTURAL SPECIALTY CODE (OSSC), 2010 EDITION OREGON ELECTRICAL SPECIALTY CODE (OESC), 2014 EDITION ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR SITE CONDITIONS. CONNECTORS SHALL BE TORQUED PER DEVICE LISTING OR ENGINEERING RECOMMENDATIONS. C: REVISION BUBBLE OREGON SOLAR INSTALLATION SPECIALTY CODE (OSISC), 2010 EDITION ALL ROOFING REPAIR MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURER'S INSTALLATION REQUIREMENTS. SHEET INDEX PROJECT TEAM FOR OFFICIAL USE ONLY LU T TITLE PAGE PROJECT DEVELOPER A.1 SITE PLAN U) LJJ A.2 ROOF PLAN NW PHOTON ENERGY, LLC U Q CV CV E.1 ELECTRICAL NOTES 560 FIRST ST. SUITE 104 E.2 ONE LINE DIAGRAM LAKE OSWEGO, OR 97034 V C) N (M W ( 503) 697-4482 W r__ 0:� E.3 SPEC SHEETS W � � � � E.4 ELECTRICAL SITEPLAN CONTRACTOR H W 0 J w NW PHOTON ENERGY, LLC J z Lo — C) M Q F- 560 FIRST ST. SUITE 104 0 N M W 0- LAKE OSWEGO, OR 97034 Cl) �- LU LU (503) 697-4482 SCALE SITE CONTACT AS SHOWN GUY ANDERSON � " 503.793.6620 ORIGINAL SIZE 24" X 36 0 SHEET SIZE ARCH "D" co co SYSTEM DESIGNER 0 %r. 1" VICINITY MAP PROPOSED LOCATION OF -. � SOLAR PROJECT RENEWABLE ENERGY ASSOCIATES, LLC a� PO BOX 208r •� 5i t: N0. REVISION DATE CU .: CORVALLIS OR 97339 " x CITY OF�'IGARD - �� o ,� �CE�VIEV�VED FOR CODE COMPLIANCE g � �� d. 541.754.2001 co ABLEASSOCIATES COM T *E .En O@R � INF ENEW Approved: s . , OTO z �. Pernut a STRUCTURALENGINEER #� " + ' ,- c ,.,.. • - -- --- ---� w 21! S ' Addres Suite#• a� TROY D. LYVER, PE/SE - . _ . Date. �.. . LYVER E INEERIN D D B3'� C � x � G GAN DESIGN, LLC 3 s. ... .u: - `iii x �v _ 7950 SE 106TH AVENUE © Copyright 2014 Renewable Energy Associates LLC.The drawings,specifications and other documents related to this h y ;` PORTLAND, OR 97266 project are protected under law and contract. Reproduction of 4 F e purpose constructing, these documents is authorized for a of PHONE: (503) 705-5283 OFFICE COPY O _ p maintaining and using this project. Use of these documents for s � ' •. ?, ..a..rr, .; � `' ����: ,�,r„ an other purpose is not permitted without Renewable Ener TROYL@LYVER-EAD.COM y p p Energy O ra °w' t' Associates'written authorization. START DATE: 9/26/13 a ELECTRICAL ENGINEER ar vJS w , - DRAWN BY: L y-r ENGINEER: ENGINEER 5 f,. n � .. r. x g PHIL HANNA APPROVED BY: RM HANNA ENGINEERING PROJECT NUMBER: (541) 359-7768 ILI3 P H I LHA N NA@ C0MCAST.NET 14-02 C e S c« CONTRACTOR m � IAL ti N SHEET NO.: NORTH LAKE CONTRACTORS d c � r ALLAN LAKE 71,i E LICENSE 154178013 12900 NW LOVEJOPY CT.? R . w PORTLAND 0 97229 R ip �y (503) 709-0985 L_ �€ R iL3 A RENEWABLE Energy Associates _ - NOTE: -PROPERTY LINES AND BUILDING LOCATIONS AREAPPROXIMATE AND ARE FOR REPRESENTATION ONLY. -PLEASE CHECK WITH CITY/COUNTY OR LAND SURVEYOR FOR ACCURATE LOCATE. PO Box 208 Corvallis, OR 97339 541.754.2001 office/fax E STAMP: SCOPE OF WORK: PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON ROOF OF EXISTING BUILDING INVERTERS(ROOFTOP) _7-771 _— ;s m W UJ c) > r-r-r-r—r—r —1 ® o C j W P_ ® ¢ N Z cr) ® ® w o 3: Q � z <C w cn � � H cn W UTILITY METER, MAIN PANEL PV SCALE GENERATION METER AND PV AC DISCONNECT 1/32" = V-0" (FIRST FLOOR ELECTRICAL ROOM) ORIGINAL SIZE 24"X 36" SHEET SIZE ARCH"D" r r «:. _ C%4 B NO. REVISION DATE .v 0 0 21 tU c N 0 .C] tU 0 Copyright 2014 Renewable Energy Associates L-C.The Q? drawings,specifications and other documents related to this Eproject are protected under law and contract Reproduction of 0 these documents is authorized for the purpose of constructing, 00 maintaining and using this project Use of these documents for any other purpose is not permitted without Renewable Energy tU Associates'written authorization. C DATE: 10!5114 v E SW CHERRY DR. DRAWN BY: is ENGINEER: N APPROVED BY: RM U PROJECT HUMBER: A 14-02 0- to REA cv SHEET NO.: Nr A01N Q N G A RENEWABLE TOTAL SYSTEM SPECIFICATIONS 58'-5" Energy Associates (242) RENESOLA-JC300M-24Ab, 300W SOLAR MODULES ^72.6 kW MOUNTED ON UNIRAC SOLARMOUNT RM COMMERCIAL ROOF RACKING AT A 10 DEGREE TILT UNIRAC RM ROOF MOUNT MOUNTING SYSTEM PO Box 208 Corvallis, OR 97339 541.754.2001 office/fax 3' STAMP: CTVq PRO 19'-42" 13'-74" 19'-114" E N 31-11 RENESOLA Q " SOLAR MODULE D. ROOFTOP RTU O EXPIRES: 12-31-11 VENT "'�,� B �- PV COMBINER PANEL RTU Q �� UTILITY METER, MAIN PANEL A.2 (ROOFTOP) 0 00 PV GENERATION METER AND PV AC DISCONNECT INVERTER#2 31'-94-3' F-1 ❑ 4'-8" (ROOFTOP) I ❑ INVERTER#1 INVERTER#3 I T--] 94' (ROOFTOP) ——— E (ROOFTOP) 7'-5� 1" ELECTRICAL — 6T-7 ROOM (FIRST FLOOR) 1 1 35'-8od 4" 4" — — [EETEE�� ° 16-14" E E 2.5' PARAPET 2.5' PARAPET C) W 4.5'PARAPET ct� aC-4 51`-11 16'1" 13'-9 " 19`-5" 10'-10-1" 25'-11" CN 2 2 U-11Q ti Z UJ 0 —� Cr ~ 0 CIL L0ry u- Z � z � `� 0 7' 235' 6' ��' 04 M 10 W LL W 248' SCALE s AS SHOWN ORIGINAL SIZE 24"X 36" g SHEET SIZE ARCH"D" -a A ROOF PLAN o �, �-2Scab: 3/32" = 1'-0" 2 a� .CDNO. REVISION DATE CJ 0 Q A rn iv LU N .o cc CD c 13" SOLAR MODULE BALLAST TRAYS 0 Copyright 2014 Renewable Energy Associates LLC.The N drawings,spea6cafions and other documents related to this E ?# project are protected under law and contract. Reproduction of these documents is authorized for the purpose of constructing, 0 maintaining and using this project Use of these documents for in I r j, SOLAR MODULE any other purpose is not permitted without Renewable Energy Associates'written authorization. c DATE: 1015/14 Y E FIN DRAWN BY: JS E Cn L ENGINEER: TL Cn N BALLAST TRAYS APPROVED BY: RM M Idda 18 19 PROJECT NUMBER: 14-02 Q N SHEET NO.: 0 C> ( BN), UNIRAC RM ROOF MOUNT PLAN VIEW UNIRAC RM ROOF MOUNT PROFILE A02 �.2Scale: NTS A.2 Scale: NTS 1 2 3 4 5 5 RENEWABLE ELECTRICAL NOTES FOR NEW PHOTOVOLTAIC SYSTEM: ELECTRICAL SAFETY FEATURES: Energy Associates ' CONDUCTOR SIZES&CALCULATIONS 1.THIS PROPOSED SOLAR ELECTRIC SYSTEM IS INTENDED TO 3. NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED THE UNIT HAS ONLY ONE MODE OF OPERATION, LINE LINKAGE CONDUCTOR,CONDUIT, AUTIa opo,s�zr s CON OPERATE IN PARALLEL WITH POWER RECEIVED FROM THE FOR PROPER GROUNDING; NOTING THAT TERMINAL LUGS MODE(GRID EXPORT MODE).THE OUTPUT VOLTAGES AND CONDUCTOR ID IN ONELINE: At A2 A3 BI B2 B3 CI C2 D UTILITY SERVICE PROVIDER. BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE CURRENTS ARE SINUSOIDAL WITH LOW TOTAL HARMONIC CURRENT-CARRYING CONDUCTOR: AWG #10 #10 #10 #10 #10 #10 #8 #8 #3PV WIRE[ I'V WIRL/ PO Box 208 INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT DISTORTION MEETING IEEE 519-1992 HARMONIC STANDARDS. POWER TO THIS BUILDING IS SUPPLIED FROM INSULATION TYPE: PV WIRE PV WIRE PV WIRE WN2 PV WIRE THWN2 THWN2 THWN2 Corvallis, OR 97339 ce/f 2.THE INVERTER FOR THE PROPOSED SOLAR ELECTRIC OF CONTACT SHALL BE PROPERLY REMOVED, 2" INSULATION TEMP RATING: DEG C 90 90 90 90 90 THWN2 ffice/f 541.754.2001 oax 090 90 90 SYSTEM SHALL BE IDENTIFIED AND LISTED AS A UTILITY THE ANTI-ISLANDING TRIP TIME IS LESS THAN (2) SECONDS AS MULTIPLE SOURCES: UTILITY AND A PHOTOVOLTAIC CONDUCTOR MATERIAL: Cu / AL CU CU Cu CU CU Cu CU Cu CU INTERACTIVE INVERTER FOR USE IN SOLAR PHOTOVOLTAIC 4. MODULES SHALL BE GROUNDED WITH EQUIPMENT PER UL 1741 STANDARDS.THE INVERTER UNIT WILL ARRAY. PHOTOVOLTAIC DISCONNECT LOCATED NEUTRAL, IF DOWN-SIZED: AWG N/A N/A N/A N/A N/A N/A N/A N/A N/A E STAMP: SYSTEMS. GROUNDING CONDUCTORS BONDED TO A LOCATION APPROVED AUTOMATICALLY SHUT DOWN WHEN THE LOSS OF GRID POWER ADJACENT TO THE UTILITY METER EGC, MIN: AWG #6 Cu #6 Cu #6 Cu #10 CU #10 CU #10 Cu #lo Cu #10 CU #8 Cu BY THE MANUFACTURER WITH A MEANS OF BONDING LISTED IS DETECTED. OVER-CURRENT DEVICE: AMPS 15 15 15 15 15 15 35 35 loo CURRENT SOURCE ED PRO6 3.THIS SYSTEM IS INTENDED TO CONNECT TO THE EXISTING FOR THIS PURPOSE. 4" CURRENT G F TYPE: ac�Dc DC Dc DC Dc Dc DC AC Ac Ac \� R t N FACILITY POWER SYSTEM AT ONE POINT,POINT OF COMMON SITE SPECIFIC INFORMATION: c� F COUPLING(POCC). THIS CONNECTION SHALL BE IN 5.THE CONNECTION TO THE MODULE OF THIS PROPOSED 2 CURRENT SOURCE. MODULE MODULE MODULE MODULE MODULE MODULE INVERTER r INVERTER 2 &3 COMBINER 1 PANEL 4 829PE , DARNING f COMPLIANCE WITH THE NEC ARTICLE 705.12"POINT OF SOLAR ELECTRIC SYSTEM SHALL BE SO ARRANGED THAT ASHRAE LOCATION: PORTLAND/HILLSBORO SOURCE MAXIMUM CURRENT: AMPS 10.s6 Io.a6 10.86 10.86 lo.s6 10.86 27.90 z4.1a 76.10 CONNECTION". REMOVAL OF A MODULE FROM THE PHOTOVOLTAIC SOURCE ASHRAE.4%DESIGN TEMP:37°C(98 6°F) COMBINED SOURCE PER CONDUCTOR: QNTY 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 CONDUCTOR MAXIMUM CURRENT, IMAX: AMPS 10.86 10.66 10.88 io.86 ia.fi6 10.x6 27 90 z4 r0 76.x0 '4REGON �` Q CIRCUIT DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ASHRAE MINIMUM TEMPERATURE:-8°C(17.6°F) y qy 240 4.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE ANOTHER PHOTOVOLTAIC SOURCE CIRCUIT. SETS OF AVERAGE HIGH TEMPERATURE: 27°C 80°F » CONDITIONS OF USE CALCULATION CIRCUIT PROTECTION FOR TESTING AND ISOLATION. MODULES INTERCONNECTED AS SYSTEMS RATED AT 50 VOLTS { ) CUSTOMER 2 LOCATION & DISTANCE FROM SURFACE: INCH ROOFTOP ROOFTOP ROOFTOP ROOF-6'/EXT ROOF-6°/EXT ROOF-6 /EXT ROOFTOP ROOFTOP INT/EXTERIOR A RUSH GENERATING CONDUIT OR FREE AIR: FREE AIR FREE AIR FREE AIR CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT r OR LESS WITH OR WITHOUT BLOCKING DIODES,AND HAVING A MODULE INFORMATION: I EXPIRATIONDATE: 5.ALL DISCONNECTS AND COMBINERS SHALL BE SECURED SINGLE OVER CURRENT DEVICE SHALL BE CONSIDERED AS A FACILITY TEMPERATURE ADDER: DEG C 0 0 0 17 17 17 17 17 0 FROM UNAUTHORIZED/UNQUALIFIED PERSONNEL BY LOCK OR SINGLE SOURCE CIRCUIT MODULE TYPE: RENESOLA JC300M 30OW FACILITY TEMPERATURE AMBIENT: DEG C 37 37 37 37 37 37 37 37 37 LOCATION MODULE ELECTRICAL SPECIFICATIONS: TEMPERATURE OF CONDUCTOR: DEG C 37 37 37 54 54 54 54 54 37 DERATE FOR TEMP: 0.91 10.91 0.91 0.76 0.76 0.76 0.76 0.76 0.91 6. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR POWER TOLERANCE(+/-W): +5/-0 40 3" CURRENT-CARRYING CONDUCTOR, QNTY: QNTY 10 a 8 10 a a 3 3 3 6.ALL DISCONNECTS, COMBINERS, PULUSPLICE BOXES,AND THEIR PURPOSE, INCLUDING BUT NOT LIMITED TO GROUND Voc:44.8V 49.23V AT-8°C { ) 3 DERATE FOR FILL / BUNDLED: 0.50 0.70 0.70 0.50 0.70 0.70 1.00 1.00 1.00 ENCLOSURES SHALL BE LISTED FOR IT'S PURPOSE. RODS, GROUNDING LUGS, GROUNDING CLAMPS, ECT. Vmp:36.6V(30.45V AT 37°C) WARNING CONDUCTOR AMPACITY. W/O DERATES: AMPS 55 55 55 140 40 40 55 55 115 ISG:8.69A CONDUCTOR AMPACITY, WITH DERATES: AMPS 25.03 35.04 35.04 15.20 21.28 21.28 41.80 41.80 104.65 7. EQUIPMENT SHALL BE INSTALLED IN A SECURE AREA. 7.WHERE GROUND FAULT PROTECTION IS NOT PROVIDED, Imp: 8.2A THIS EQUIPMENT FED BY MULTIPLE SOURCES. MIN AMPACITY REQUIRED >= IMAX: 10.86 10.86 10.86 10.86 10.86 10.86 27.90 24.10 76.10 INVERTER PERFORMANCE MAY BE AFFECTED IF INSTALLED IN EACH GROUNDING CONDUCTOR SHALL BE SIZED TO TWICE THE SERIES FUSE RATING: 15ATOTAL RATING OF ALL OVERCURRENT DEVICES, TERMINAL CALCULATION, DIRECT SUNLIGHT. NORMAL CALCULATED AMPACITY PER NEC 690.45(B). Vac CORRECTION(%/°C):-0.30% EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE 2" TERMINAL TEMP RATING: DEG C 75 75 75 75 75 75 75 75 75 OPERATING AMBIENT TEMP. RANGE:-130F TO+131°F Vmp CORRECTION(%/°C): -0.40°l0 ' CONDUCTOR AMPACITY, AT TERMINALS: AMPS 50 50 50 35 35 35 50 50 loo D STANDBY/STORAGE AMBIENT TEMP RANGE: -22°F TO+158°F GROUND FAULT PROTECTION: SHALL NOT EXCEED AMPACITY OF BUSBAR. MIN AMPACITY REQUIRED >= IMAX X 1.25: AMPS 13.58 13.58 13.58 13.58 13.58 13.58 34.86 30.13 95.13 TYPE OF PROTECTION: NEMA 3R INVERTER INFORMATION: OVER-CURRENT , ��.�, 777777 SEE SPEC SHEET(E.3)FOR MORE INFORMATION 1. PHOTOVOLTAIC INVERTERS SHALL BE EQUIPPED WITH DC MIN AMPACITY REQUIRED >= IMAX x 1.25: AMPS 13.58 13.58 13.58 13.58 13.58 13.58 34.88 30.13 95.13 GROUND FAULT PROTECTION TO REDUCE FIRE HAZARDS. INVERTER MODEL: ADVANCED ENERGY AE 3TL-23 48OV, 3(� OCD USED: AMPS 15 15 15 15 15 15 35 35 100 WIRING METHODS: CEC WEIGHTED EFFICIENCY: 98% 4" CONDUIT(APFEjVDi?I C) .. �. ~ °�� F , DISCONNECTING MEANS: INVERTER MAXIMUM VOLTAGE INPUT: 50OVDC TOTAL CONDUCTORS: ONTY II 9 9 11 9 9 5 5 5 ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL INVERTER DC VOLTAGE OPERATING RANGE: 125-45OVDC SIZE (& MAX CONDUCTOR QNTY): IN(QTY) BUNDLED BUNDLED BUNDLED 1' 1' I' .75' 75' 1.25• CONFORM TO THE NATIONAL ELECTRICAL CODE(NEC), LOCAL 1. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT INVERTER MAXIMUM POWER INPUT:40r60ODC 4 vOLTAGDROP STATE CODES AND OTHER APPLICABLE LOCAL CODES CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER INVERTER MAXIMUM POWER OUTPUT:23000WA C PHaEavaLTAIC DISTANCE, i DIRECTION. KFT 0.030 0.080 0.050 0.050 0.005 0.035 0.025 N 0.080 6.045 SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. INVERTER MAXIMUM CURRENT OUTPUT:27.9AAC RESISTANCE: OHMS/KFT 1.2400 1.2400 1.2400 1.2400 1.2400 1.2400 0.7780 0.7780 0.2450 1. EXPOSED PV SOLAR PANEL WIRING FOR A TRANSFORMER INVERTER AC NOMINAL VOLTAGE OUTPUT: 480VAC DC DISCONNECT SOURCE OPERATING CURRENT: AMPS 8.20 8.20 8.20 8.20 8.20 8.20 27.90 24.10 76.10 BASED INVERTER PV SYSTEM WILL BE USE-2,90 DEGREE C, 2. THE DISCONNECTING MEANS SHALL NOT BE REQUIRED TO AC OVERCURRENT PROTECTION: 35A # OF SOURCES PER CONDUCTOR: QNTY 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2" CONDUCTOR OPERATING CURRENT, IOP: AMPS 8.20 8.20 8.20 8.20 8.20 8.20 27.90 24.10 76.10 WET RATED AND UV RESISTANT. BE SUITABLE AS SERVICE EQUIPMENT AND SHALL BE RATED IN WARNING: TEMP CORRECTED(ASHRAE .2%) VMP: VOLTS 287 319 287 287 319 287 480 480 480 ACCORDANCE WITH SECTION 690.17. INVERTER MODEL: ADVANCED ENERGY AE 3TL-20 480V, 3(p ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. VOLTAGE DROP, TOTAL: VOLTS 0.611.63 1.02 1.02 0.r0 0.71 1.09 3.00 1.68 2. EXPOSED PV SOLAR PANEL WIRING FOR A CEC WEIGHTED EFFICIENCY: 97.5% TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE VOLTAGE DROP,PERCENTAGE: % 0.21 10.51 0.35 0.35 10.03 10.25 10.23 0.62 0.35 TRANSFORMER-LESS BASED INVERTER PV SYSTEM WILL BE PV 3.A SINGLE DISCONNECTING MEANS SHALL BE PERMITTED FOR INVERTER MAXIMUM VOLTAGE INPUT: 500VDC ENERGIZED IN THE OPEN POSITION. WIRE,90 DEGREE C, WET RATED AND UV RESISTANT. THE COMBINED A.C. OUTPUT OF ONE OR MORE INVERTERS IN INVERTER DC VOLTAGE OPERATING RANGE: 125-45OVDC NOTES: AN INTERACTIVE SYSTEM. INVERTER MAXIMUM POWER INPUT: 35,000DC 10 1. Isc- SHORT CIRCUIT CURRENT 3. ALL EXPOSED CABLES, SUCH AS MODULE LEADS SHALL BE INVERTER MAXIMUM POWER OUTPUT:20000WAC PHOTOVOLTAIC 2. CC = CONTINUOUS CURRENT E SECURED WITH MECHANICAL OR OTHER SUNLIGHT RESISTANT REQUIRED SAFETY SIGNS AND LABELS: INVERTER MAXIMUM CURRENT OUTPUT: 24.1AAC E N E RAT I O N METER 1" 3. NEUTRAL IS NOT CURRENT CARRYING MEANS. INVERTER AC NOMINAL VOLTAGE OUTPUT: 480VAC O 4.VOLTAGE DROP IS THE.WORST CASE SCENARIO U) 1. REQUIRED SAFETY SIGNS AND LABELS SHALL BE AC OVERCURRENT PROTECTION:35A PHOTOVOLTAIC C LU U) 4.ALL GROUNDED CONDUCTORS SHALL BE WHITE OR GRAY PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER C!) > co LLJ AND EQUIPMENT GROUNDING CONDUCTORS GREEN OR BARE. MECHANICAL MEANS. LABELS SHALL COMPLY WITH ARTICLE ARRAY ELECTRICAL SPECS: DC DISCONNECT C_) Q N (NEC 200.6). LABEL COMBINER BOX WIRING RED FOR POSITIVE, 690 Vl OF THE NEC OR OTHER APPLICABLE STATE AND LOCAL 2" 0 N WHITE FOR NEGATIVE AND GREEN FOR GROUND. CODES. SEE LABELS AND MARKING. 3TL-23 INVERTER-INVERTER#1 RATED MAX POWER POINT CURRENT: 82 AMPS 11 WARNING: P H OTOVO LTAI C a N RATED MAX POWER POINT VOLTAGE: 329 VOLTS DC » Of 5_ALL FIELD WIRING THAT IS NOT COLOR CODED SHALL BE GENERAL NOTES GRID TIE PHOTOVOLTAIC INVERTERS: MODULE QUANTITY:90 MAX SYSTEM VOLTAGE: 443 VOLTS DC POWER SOURCE 1 E < I. MARKED AT BOTH ENDS WITH PERMANENT WIRE MARKERS TO INVERTER QUANTITY: 1 MAXIMUM SHORT CIRCUIT CURRENT: 109 AMPS E C1 3: 0 IDENTIFY POLARITY AND CIRCUIT IDENTIFICATION. 1.TRANSFORMER BASED INVERTERS ARE SUPPLIED WITH AN STRING SIZE: 9 4" LABEL AND MARKINGS LEGEND: 'tom ~ INTEGRAL HIGH EFFICIENCY ISOLATION TRANSFORMER AS STRINGS PER INVERTER: 10 < in M Q C) 6. CONDUIT TYPES USED IN THE PV INSTALLATION SHALL BE PART OF THE INVERTER ASSEMBLY. TOTAL STRINGS: 106O a E Lo o J J APPROVED FOR THEIR SPECIFIC APPLICATION AND SUPPORTED STG RATING OF ARRAY: 27,000 WDC PHOTOVOLTAIC THIS PLAQUE SHALL BE APPLIED TO THE MAIN SERVICE 0 Cn w PROPERLY PER NEC. 2. TRANSFORMER-LESS(NON ISOLATED) INVERTERS ARE NOT MAXIMUM SYSTEM VOLTAGE:443.1V 12 DISCONNECTING MEANS. (1 TOTAL) UJ CC SUPPLIED WITH AN INTEGRAL HIGH EFFICIENCY ISOLATION RATED MAX POWER POINT VOLTAGE:329.4V DC DISCONNECT PHOTOVOLTAIC w w HAVE EXPA7. LONG NSION FITTINGS,GHT FRUNS, 100 FEET OR IF EXPOSED TO WEATHER. SHALL TRANSFORMER AS PART OF THE INVERTER ASSEMBLY. RATED Isc OF ARRAY:USTED Vmp gq°�)OF ARRAY:274V RATED MAX POWER POINT CURRENT: 66 AMPS 2" POWER SOU RCE WARNING LABEL FOR EXISTING UTILITY PGE METER. (1 TOTAL) SCALE AS SHOWN 1'7 3.TRANSFORMER BASED INVERTERS ARE INTENDED TO BE MAXIMUM SHORT CIRCUIT CURRENT: 108.6A RATED MAX POWER POINT VOLTAGE: 366 VOLTS DC 2" WARNING: ELECTRIC SHOCK HAZARD. 3 PROVIDES INFORMATION ON THE USE OF THE AC COMBINER 6 8.ALL DC MATERIALS SHALL BE LISTED FOR 600V DC INSTALLED AS PART OF A PERMANENTLY GROUNDED RATED MAX POWER POINT CURRENT:82A MAX SYSTEM VOLTAGE: 492 VOLTS DC THE DC CONDUCTORS OF THIS LOAD CENTER.APPLY TO NEW LOAD CENTER. 1 TOTAL ORIGINAL SIZE 24"X 36" ELECTRICAL SYSTEM PER THE NEC ANSI/NFPA 70.A GROUND MAXIMUM SHORT CIRCUIT CURRENT: 87 AMPS ( ) 9. CONDUITS AND CONDUCTORS:ALL INTERCONNECT WIRING CONNECTION FOR THE TRANSFORMER AND INVERTER MUST BE 3TL-20 INVERTER-INVERTER#2 PHOTOVOLTAIC SYSTEM ARE SHEET SIZE ARCH"D" UNGROUNDED AND MAY BE ENERGIZEDPHOTOVOLTAIC DC DISCONNECT GENERIC WARNING LABEL. AND POWER CONDUCTORS INTERFACING THE UNIT MUST BE IN INSTALLED AND CONNECTED TO THE UNIT AS DESCRIBED IN CM ACCORDANCE WITH THE NEC ANSI/NFPA 70 AND ANY THE INSTALLATION MANUAL THE AC AND DC GROUND BUS MODULE QUANTITY: 80 7 4 APPLY TO DC DISCONNECT(S). (3 TOTAL) 0 �21r APPLICABLE LOCAL CODES. LARGE GAUGE WIRE MUST BARS ARE CONNECTED TO THE MAIN INVERTER ENCLOSURE. INVERTER QUANTITY: 1 PHOTOVOLTAIC 3" B N CONFORM TO THE MINIMUM BEND RADIUS SPECIFIED IN THE THE GROUND FAULT FUSE IS MONITORED AND THE INVERTER IS STRING SIZE. 10 PHOTOVOLTAIC DC DISCONNECT OPERATING SPECIFICATIONS NEC,ARTICLE 300.34. KEEP ALL WIRE BUNDLES AWAY FROM DISCONNECTED FROM THE GRID IN THE EVENT OF A GROUND STRINGS PER INVERTER: 8 DC DISCONNECT LABEL APPLIED TO DC DISCONNECT ON INVERTER WITH 10 NO. REVISION DATE 0 ANY SHARP EDGES TO AVOID DAMAGE TO WIRE INSULATION. FAULT. GROUNDING ELECTRODE SYSTEM CONDUCTORS SHALL STC RATING OF ARRAY: 24,000 WDC 2" GENERAL NOTES FOR LABELS AND STRINGS OF 9 MODULES. (1 TOTAL) ALL CONDUCTORS SHOULD BE MADE OF COPPER AND RATED BE SIZED PER NEC 69G.47. MAXIMUM SYSTEM VOLTAGE:492.3V RATED MAX POWER POINT CURRENT: 66 AMPS FOR 90 DEGREE C MINIMUM. FOR OUTDOOR INSTALLATIONS, RATED MAX POWER POINT VOLTAGE:366V RATED MAX POWER POINT VOLTAGE: 329 VOLTS DC MARKINGS: ALL INTERCONNECT CONDUITS AND FITTINGS MUST BE NEMA-4 4.TRANSFORMER-LESS INVERTER SHALL HAVE AN EQUIPMENT ADJUSTED VmpASHRAE.4% OF ARRAY:305V PHOTOVOLTAIC DC DISCONNECT OPERATING SPECIFICATIONS { ) MAX SYSTEM VOLTAGE: 443 VOLTS DC LABEL APPLIED DC DISCONNECT ON INVERTER WITH 8 STRINGS RATED AS REQUIRED BY THE NEC. GROUNDING CONDUCTOR BONDED TO THE EXISTING RATED Isc OF ARRAY: 69.5A MAXIMUM SHORT CIRCUIT CURRENT: 87 AMPSJ 1. LABELS AND MARKINGS SHALL BE APPLIED TO GROUNDING SYSTEM.A GROUND CONNECTION FOR THE MAXIMUM SHORT CIRCUIT CURRENT:86.9A OF 10 MODULES. (1 TOTAL) THE APPROPRIATE COMPONENTS IN ACCORDANCE 10. CONNECTORS TO BE TORQUED PER DEVICE LISTING,OR INVERTER MUST BE INSTALLED AND CONNECTED TO THE UNIT RATED MAX POWER POINT CURRENT:65.6A 3" MANUFACTURERS RECOMMENDATIONS. AS DESCRIBED IN THE INSTALLATION MANUAL. THE AC AND DG WITH THE NEC. PHOTOVOLTAIC DC DISCONNECT OPERATING SPECIFICATIONS Copyright 2014 Renewable Energy Associates LLC.The w GROUND BUS BARS ARE CONNECTED TO THE MAIN INVERTER - 3TL-20 INVERTER-INVERTER#3 �8 LABEL APPLIED DC DISCONNECT ON INVERTER WITH 8 STRINGS drawings,specifications and other documents related to this E SOLAR AC project are protected under law and contract Reproduction of 11. ALL AC WIRING SHALL BE COPPER WIRE,TYPE THWN-2 ENCLOSURE.THE GROUND FAULT FUSE IS MONITORED AND 2. SOLAR MODULES ARE SUPPLIED FROM THE OF 9 MODULES.(1 TOTAL) these documents is authorized for the purpose of constructing, -a0 RATED AT 90 DEGREE C,AND RATED FOR 60OV, OR APPROVED THE INVERTER IS DISCONNECTED FROM THE GRID IN THE MODULE QUANTITY:72 MANUFACTURER WITH MARKINGS PRE-APPLIED TO maintaining and using this project Use of these documents for any other purpose is not permitted without Renewable Energy EQUAL. EVENT OF A GROUND FAULT.EQUIPMENT GROUNDING INVERTER QUANTITY: 1 DISCONNECT MEET THE REQUIREMENTS OF THE NEC. 8 AC SERVICE DISCONNECT WARNING LABELAPPLY TO MAIN PV Associates'wnttenauthodzation. . CONDUCTORS SHALL BE SIZED PER NEC 250.122. STRING SIZE: 9 2» START DATE: 10/5/14 SYSTEM AC DISCONNECT. (1 TOTAL) DRAWN BY: JS 12. PROPERLY SUPPORT ALL EXPOSED PV SOURCE CIRCUITS STRINGS PER INVERTER: 8 3. THE INVERTERS ARE SUPPLIED FROM THE 10 TO MAINTAIN THE INTEGRITY OF THE CONDUCTOR'S 5. INVERTERS ENCLOSURES ARE INDOOR/OUTDOOR RATED' IEC STC RATING OF ARRAY: 21,600 WDC OPERATING CURRENT:76.1 AMPS ENGINEER: pi{ MANUFACTURER WITH THE APPROPRIATE LABELS g LABEL FOR POCC PV BREAKER. 1 TOTAL co INSULATION. GRADE, NEMA 3R.ALUMINUM CONSTRUCTION WITH ENAMEL MAXIMUM SYSTEM VOLTAGE:443.1V OPERATING VOLTAGE:480 VOLTS AC { ) AND MARKINGS TO MEET THE REQUIREMENTS OF APPROVED BY: RM v COATED PAINT ON ALL SURFACES.ALL REMOVABLE INTERNAL RATED MAX POWER POINT VOLTAGE:329.4V THE NEC. PROJECT NUMBER: GROUNDING: PANELS ARE COVERED WITH ENAMEL COATED PAINT ON ALL ADJUSTED Vmp(ASHRAE_41°) OF ARRAY:274V 10 LABEL FOR SYSTEM OWNERS KWH GENERATION METER. SURFACES.ALL SURFACES ARE TREATED WITH A ZINC-RICH RATED Isc OF ARRAY:69.52A (1 TOTAL) SEE ELECTRICAL DIAGRAM AND ELECTRICAL DETAILS FOR PRIMER AND THEN POWDER COATED TO INHIBIT CORROSION. MAXIMUM SHORT CIRCUIT CURRENT:86.9A WARNING 4. TEXT LABELS WILL BE ETCHED WITH LETTERING A 14-02 MORE GROUNDING INFORMATION. RATED MAX POWER POINT CURRENT:65.6A INVERTER OUTPUT CONNECTION ON PLASTIC PLACARDS. THE LABEL WILL BECL PHOTOVOLTAIC POWER SOURCE LABEL. APPLY TO ALL 6. INVERTER OPERATING CONDITIONS ARE DESIGNED TO BE DO NOT RELOCATE THIS DEVICEONMENT. ATTACHED TO THE APPROPRIATE COMPONENT 11 1. ONLY ONE CONNECTION TO DC CIRCUITS AND ONE INSTALLED IN EITHER AN INDOOR OR OUTDOOR ENVIRONMENT. 1" EXPOSED RACEWAY CABLE TRAYS PULL BOXES AND 12 ENCLOSURES IN CONSPICUOUS PLACES USING JUNCTION BOXES THAT CONTAIN PV POWER SOURCE OPERATING CURRENT: 761 AMPS SHEET CONNECTION TO AC CIRCUITS WILL BE USED FOR SYSTEM THE UNIT MUST BE ANCHORED TO A LEVEL CONCRETE FLOOR . TWO PART EPDXY. N GROUNDING(REFERENCED TO THE SAME POINT).THIS WILL OR STEEL PLATFORM.ALLOWABLE OPERATING TEMPERATURE OPERATING VOLTAGE:480 VOLTS AC CONDUCTORS. NORMALLY BE LOCATED AT THE POCC. RANGE FOR THE UNITS ARE SPECIFIED BY THE MANUFACTURER. 12 LABEL FOR INVERTERS AND JUNCTION BOXES . (9 TOTAL) 2. EQUIPMENT GROUNDING CONDUCTORS AND SYSTEM E01 E GROUNDING CONDUCTORS WILL HAVE AS SHORT A DISTANCE +v a- TO GROUND AS POSSIBLE AND A MINIMUM NUMBER OF TURNS 1� + Q RENEWABLE Energy Associates ------------ ------ ------------- PO Box 208 Corvallis, OR 97339 541.754.2001 office/fax FREE AIR FREE AIR STAMP: (10)#10 PV WIRE (10)#10 PV WIRE (1)#6 GND TYP. (1)#6 GND TYP. MAX.-30'W/0.21%VD MAX.-30'W/0.21%VD PROF�Fs I N (1) 1" EMT4 829PE (10)#10 PV WIRE + (1)#10 GND -5W/0.04%VD 1r�o�Q\7�� ----------- ------ -- ------- ----- RUSH + � i (1) 1"EMT EXPIRATION DATE: 5 (10)#10 THWN-2 = _ (1)#10 GND ——————— ----- -------- ------------ — — -50'W1 0.35%VD 17 FREE AIR FREE AIR (8)#10 PV WIRE (8)#10 PV WIRE (1)#6 GND (1)#6 GND ~80'W/0.51%VD -80'W/0.51%VD (1) 1" EMT (8)#10 PV WIRE (1)#10 GND N + 16 (1) 1" EMT -5W/0.03%VD (8)#10 PV WIRE _ _ _ _ (1)#10 GND ----------- - ------ ————————————— — — — — -5W/0.03%VD (1) 1-EMT ——————— ----- --------- ----------- — — — — — — — — — - - LF (8)#10 PV WIRE. - (1}#10 GND TYP. FREE AIR FREE AIR ~5`W/..04°loVD (8)#10 PV WIRE 3 (8}#10 PV WIRE (fi) fi" EMT (1)#6 GND (1)#6 GND ($)#10 THWN-2 ~50'W/0.35%VD ~40'W/0.28%VD (1)#10 GND -35'W/0.25%VD -- UTILITY B MAIN SERVICE DISCONNECT (� 14 W �✓ U) >_ W SD W > Q U Q NO 9 C) Dc 1 2 3 4 5 6 RENEWABLE Energy Associates PO Box 208 X. r �i Corvallis, OR 97339 \ AV z SPECIFICATIONS 541.754.2001 office/fax ReneS-0-.�.\�.- ia T..:� I� E STAMP: ADVANCED M 0 U N I R M L\CENERGY ill \ .f \ :, �� o :::< �� �� � } la,,i< < � � � \�� PROTECT CHARACTERISTICS , E03 M. "3 p Allowable Roof Slope: 3 Degrees \ a Lim _ _._ Series Unevenness: +!-3.5 degrees......._.__ _ AE 3TL 600 i Max Building Height: 100 ft str t � � � Wind Speed: U to 120 mph x less �... � � . Three-Phase �rar� orn i� Y�...�., �, .___... _... ....__.. .... ...... ` Errdency Hi h Module Conversion Efficiencies _w. 8 uu _ T Wind Exposure: Categories B and C. (D Upon Request} Stringinverter ���vv , � a - - � _� _ _ '". PSF on Roof: As low as 3.5 PSF ' a . ; Surfaces: EPDM, PVC&TPO Membranes, Bitumen &Concrete The AE 3TL 600 Series adds broader functionality to a �� \�v� Min.Local Contact Area: 38 int per Module (57 in'with Roof Pad v r` �rwia Easy Installation and Handling -- p -- -- } proven robust design.With over 3 GW installed worldwide, __ Module Orientation: landscape it is a well established product with a great reliability track \ i - e - _.. \���\ � NaminalMadule7ittAngle: 10 Degrees(Nominal) THE POWER record.The AE 3TL also is lightweight and easy to install. � � ��'` r,_._ Row Spacing: 19 in Nominal f` _ .... With a peak efficiency over 98/and versatile monitoring \v�t t va gay111", OF SIMPLICITY options, this is the field-proven string inverter of choice for ' On on, Mechanical Load Capability of up to 5400 Pa ro ect developers, site designers,and installers. �� ; p ; p g � - COMPONENTS MATERIALS w... .. "4410, a� , p ROOF MOUNT introduces the Power Ballast Ba Aluminum 6063 T5 \\��� �� y The AE 3TL is designed with many different applications __ _ _. _ __ a\a ��� m � OfSim �ICit tOthe�}a�}a5tedfl.atr00f Module Clamp Aluminum 6005AT61 in mind.These high-quality inverters can be used for Conforms with IEC 61215:2005, p y - - commercial rooftop and carport installations,as welti6c a! IEC 61730:2004,UL 1703 PV Standards solar industry. The system consists Locking 3/8"Hex Bolt Stainless Steel 300 Series `- -JRoof Pad TPE 70 Shore A as solar power plants.With a power range of 12 to 23.2 Of only two major components, -Versatility minimizing kilowatts, the AE 3TL is situated to serve installations large minimizing preparation Work and • Wide range of output power allows for integration on a variety \ u and small.The AE 3TL optimizes space in the site design, installation time.SeamLes5l design of site designs,with an emphasis on design flexibility and ��\�' ? y g BALLAST BAY GEOMETRY D and allows for flexible placement within the array, saving site project yield, L ceroamuen1' ISO9001,OHSAS18001,IS014001 Certified around roof obstacles, Support "" ......... _ _ Width: 21 in owners highly valued space. __.._ • Superior efficiency,low shipping costs,and distributed design most framed modules and bond -•-------------•----•-.___- _. ..__..... _.._.._ _._ ._.._ offer solar stakeholders increased return on investment and Length: 17 In the system with just the turn of a ---- _��--- Highly precise MPP tracking combined with AE advanced Height: .13-in reduced upfront costs, wrench. Weight: 3.5 lbs monitoring solutions gives solar stakeholders the vital data . Maximizes space for energy production needed to operate and maintain a highly efficient site, • Optional AFCI Roof Pad: 3 in x 10 In providing maximum return for investors in solar energy. • Unprecedented 1.75 DC:AC ratio enables lowest inverter cost per DC Watt. MODULE COMPATIBILITY a° 100% 5� ' 1 `,off r. AE listens carefully to customer demands.The AE 3TL Reliability ° is fully compliant to NEC 2011 with standard serviceable . 3 GW installed worldwide esu �V material& Standard 60 and 72 Cell t=rained Modules touch-safe'fuses and optional AFCI.Weighing just over c1 90°� y workmanship , a Module Clamp w/Integrated Bonding to t1L2703 • Proven reliability i, 100 pounds, the easily installed inverter is very well suited • - _ • Low maintenance 85% � Cable Management Compatible w/Strut Accessories for rooftop or space-constrained installations,Additional �+ • Improved system uptime E 8Ok O\vvmvv �a° 2s savings are recognized with lowered shipping costs,.and there is no need for the heavy machinery associated with Superior instail ilit � o% 0 1� s _o is o Z5 i'newer � WARRANTY&CERTIFICATIONS installing larger, heavier inverters.Arrays designed with the • Lightweight,easy to install 'FfCAI? .``"-"""" """""""'"""""�"�"' 20 Year Manufacturing AE 3TL string inverters have best-in-class uptime,system • Less space needed on site UL 2703 Certification yields,and problem resolution, • Lowered balance of system(BoS)costs ♦ waaovEdPsdlx cT AN } • Inverters closer to array c©us SII i „ �� PV dYCLE uSfID ` d.r� Intertek ; �r I L Sod m ` a rw6U b ^. tSCs 3 s<S� r ;�'rps ,iryriaht 0 2013-2014 C Inc 0_a S i x�ep� t.j1-- 0 s,`ixpasusr„ 0-tega,Iy 8 AE Solar Energy is a US based company. luhts esr e i h.:1410425 �,.Lute W U) ) 0 Oe C w U Q co il t�� CV AE 3TL 0 oriel 3 �� ry ecifi ti � � �:��t Q p �` ���'� � ���� � ��� ����� � � 0 Options � : v � t Mechanical AE 3TL-12 AE 3TL-16 AE , O 21'(W)x 35'{M x 11'(D) {Ss'S x 895 x 280 fmrnll •5.10.and 15 year warranty Re, � ••.\v°_ cOW, , �.�. 108 Ib 09 kg) extension;Extensions are .••. o�o �°v�oa v N LU NEMA 41 connection box NFMA 3R � � � optional. .t Q O w Terminal block 8-12 AWG \ �e g Terminal block 6-10 AWG Premium monitoring solutions �� � 992mm SOmm 947mm � � ��/� LCD ___...._ �_> V J � ) AFCI I ! ( I _ „µis/ t000wm� A 1 P i at Mo •f i i "it Q L(') LL 1 a\ �\ � \ �� ' 1 r 1 I IUNCrteNeOY aiA1xIClC g `J \� � \ 21 kW 28kW 35 kW 40.6 kW ' ( I i 8-, 500UJ Ungrounded,dual array a e \\\c\ O �y F- \��" ° g 2x27.5A 2x33A 2x37.5A 2x40A €: ' 600wtm= �\ �uv � Wks v J r UJ 18 ;, .� 1� 2 x 76 A 4 The Advanced Energy 3TL horizontal mounting kit ~ W Cn _r •��W�: 125'V to 450 V e f $ s e 4o0wm,' v v v uJ x � � �� •�fMy 225V 250V 275V 300V i I provides a compact and cost-effective means to install U1 �3 ,� 200 V ° u LJJ v : _...., \�.• v SCALE o AE 3TL stringinverters in a horizontal orientation. This U' ���� •• °° n 40 AS SHOWN \� `ate ., 12 kW 16 kW 20 kW 23.2 kW € i x■sYs Voltage(Vj ���o�U�. �`�\�a`\�� °' �� _ 423 to 526 V innovative option is essential for installers and designers \ 1- ikAPipN$iplF. W \ro\ \ 1� I tE`. i iii \ C Q ` i i ��? \ 12 kVA 16 kVA 20 kVA 23.2 kVA \� l ! [ ,i °�"• � � �� that need to comply with NEC 2014 Rapid Shut Down n tl co U ��� • �Caus� �.�.' 3 AC 480 V Wye+N L 14:5 A 19.3A 24.1 A 27.9A , _ E, r., ,tr :-» ORIGINAL SIZE 24 X 36 • ,, ,, 16.5 A:duration<10 21 A;duration<10 26 A:duration<10 29 A;duration<10 ' I` ' € trraetante 2oow/m= 400w/m= 'snnw/mr snow/m= i000w/m=', al requirements by enabling a low-profile installation at the SHEET SIZE ARCH "D" �� �� Drawing Only for Reference Efficiency _. _ a `__.€ I J J rT1SfC mSCC mSCC msec � � cry 35.8% 16.2% 16.2% 16.1% .16.0% v `mg �`°"�` � 60 Hz (57 Hz to 63 Hz adjustable) CU �,,� � 01 ��� <3% o� edge of the solar array. The horizontal-mount option also ' S '� `` �'` 0 1 � � 98,2% 2 _0 1� � 8 Maximum PowertPmax) 300w 305w 310w „ k �n I facilitates more profitable system designs by eliminating 97.5% 97.5% 97.5% 98% B 11 \\\\\\ Power Tolerance 0-+5W 0-+5W 0-45W " ��\� <o.s w Module Efficiency 15.5% 15.7% 16.0% Shading setbacks for inverters. a I)I- I€x '�0 U) inverterControls•nd Monitoring \ e Maximum Power Current(imp) 8.20A 8.33A 8.33A 12< - a In accordance with IEEE 1547 and UL 1741 NO. REVISION DATE Maximum Power Voltage(VmP) 36.6 V 36.6 V 37.0 V. (� �"�"`\�`�\\ "�`�°`� ���� %� ±0.99 standard,lettable from+0.90 U \� - Short Circuit Currenttlsc) 8.69A 8.73A 8.80A The kit is designed and rated for Installation This Soiutfon also enables rapid conversion to open Circuit Voltage(voc) 44.8 v 44.9 V 45.0 v , E �� ��\ �\ Ethernet;RS-485 and apetatiU^in direct Sort.as well as rasa AC power:which cion reduce e cast and simplify \a + Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance loom/m=,Cell Temperature 25°C) ENMESEEIMERM Environmentaland snow.ft also includes a sun shade,two system design and installation. s s \ R 13 F to+1311F �. �<:�. \ a,;..,,..a .\ {cw-power cooling fans,and a base assembiy -2s°c to+ss°c) ooY� o ����� oo� \ m�s������� p t; �. that is quick and easy to install,The mounting - 2°F to+158°F Maximum Power(Pmax) 222W 225 W 230 WDURA- 2 .: flan ware cam atible with BLOK"y (-300C to+7QQQ \ Maximum Power Current(Imp) 6.67 A 6.72 A 6.80A Natural convection and UNiSTRUT4 hardware,which allow for CU ...i Maximum Power Voltage tVmp) 33.4V 33.6V 33.9V ,•, ;,$ t � �� 95 before deratm9 site-specific,customized moon>ing solutions. : \ Short Circuit Current(lsc) 7.02A 7.04A 7,10A _ 6500'before derating Open Circuit voltage(Voc) 41.9V 42.0 V 42.1 V tri MO. a�� ��� ��. 45 d6A at 16-5' , Our ,.0 o'rC, \\� �a�.�",\\�O a•, Valuesat Normal Operating Cell Temperature,Irradiance of 800Wfmt.,spectrum AM l.S,ambient temperature.20°{,wind speed i N �� a. p .g .: \ O ©Copyright 2014 Renewable Energy Associates LLC.The \° Q UL 1741,1699B,IEEE 1547,CSA 022.2,FCC Part 15(Class A and B) ; a aa000\� \�\ a \ �\ t18 'ii \ drawings,specifications and other documents related to this !_ 4 `.` � .;.. 5 years standard,extendable to 201 years Cell Type 156x156 mm Polycrystalline,72.(6x12)pcs in series Temperature Coefficient of Voc -0.30%rc project are protected under law and contract. Reproduction of • ° AE-3TL-12-6-08 AE-3TL-16-6-08 AE-3TL-20-6-08 AE_.3TL-23_6-08 Dimensions of Inverter and Horizontal Mounting Kit Assembly these documents is authorized for the purpose of constructing, U - Glass High Transmisslon,Low Iron,Tempered Glass Temperature Coefficient of Ise 0.04%/°C 0 AE-3TL-12-6 AE-3TL-16-6 AE-3TL-20-6 AE-3TL-23-6 `(.' maintaining and using this project. Use of these documents for _0 - - Frame Anodlzed Aluminum Alloy Temperature Coefficient.of Pmax. -0.40%/'C 6X0.281 any other purpose is not permitted without Renewable Energy 5. Subject to change without notice.Refer to usermanualfor detailed Specification.. Junction Box IP65/IP67 rated,with bypass diodes Nominal Operating Cell Temperature(NOCT) 45°Ci2°C Associates'written authorization. • 23,50-i 0 *vol alt performance window speclflpatiorts can be achieved simultaneously.Performance varies persite. D;mens;on "195sx99zx5omm gg,o6START DATE: 10/5/14 C ""Derating at temperatures>1227{5()*Q for the 12 kW and 16 kW3;>113°F(45°C)for 20 kW:>104°F(40°C}for 23 kW Output Cable 4 mm=(EU)j12 AWG(US),3000 mm vconsult your AE sales or service representatives for specific Pit system design questions at saies.support(aae,com, weight 29 xg C ("l ;� DRAWN BY: Jg C Installation Hole Location See Drawing Above O I O �' J ® (S 13.89 C ENGINEER: PH CD Container 2(Y GP 40'GP 40'Hq operating Temperature -40'C-+SVC APPROVED BY: RM 0 Pallets per Container 10 24 24 Maximum system Voltage 1000VDC(EU)1600VDC(US) 20.70--------- Pieces per Container 200 480 528 Maximum Series Fuse Rating. 20A(EU)/15A(US) • PROJECT NUMBER: �--a.3a Seo No:x:/10)!]611 u7 M ma:m�da for N m:°&ae"s twuox:antMeleseMaaeae-a�Jmeanaa bk�t,�Usnaewxsau4 cncr.noere. 14.00 4.00 7.12 A 14-02 Advanced Energy lgdustr es,Inc. ADVANCED fada aEn�gymaa:ries:€ee SHEET NO.: � 162 Snare Point ori •For Collins,iCO 80525 U.S.A. LIE: '"'� www.advanced-en Auroras reserved.Printed inv.S.A, l CV E 800 4469167 sates.su ort(aae,.com•invertersu ENG AE5TL c>N2 250-05.4114 PP pport(faael.com $ Advanced Energy'is a U.S.trademark of Advanced Energy Industries,Inc. r N ReneSola.com 0 -ate ^L LL 1 2 3 4 5 6 RENEWABLE Energy Associates PO Box 208 Corvallis, OR 97339 541.754.2001 office/fax E STAMP: PRO,cFF 1 N F s�0 8 9P �9 REGON 0 Q" RUSH EXPIRATION DATE: 3O JS D INV, SC-2 INV 1 SC-3 INV 1 SC-4 INV 1 SC-5 INV 1 SC-1 INV 3 [�F `W 1 7 S�1 PV GENERATION METER&AC DISCONNECT EFINV3 C W J INV2 (FIRST FLOOR ELEC ROOM) (n COMBINER PANEL (ROOFTOP) — Q W U N W r INVERTER#3 N INVERTER#2 ELECTRICAL ROOM ON FIRST FLOOR (ROOFTOP) �— ti U� SC-2 INVERTER#1 z INV 2 (ROOFTOP) (ROOFTOP) 0 UTILITY METER & MAINS (POCC) W I.-- � Q SC-3 L — —.— — J (FIRST FLOOR ELECTRICAL ROOM) NV3 W 0_ V Z Q 3 J INV - - - - ,^ SC- 1 + NQ sc-s Q L J U LU INV1 J M UJ, SC-8 SC-4 '`1/1J 1 1 1 SC-4 INV 3 U) INV 2 NV 3 N M w J S V1 CONDUIT BRIDGE LU r-1 F— W LU SC-5 � INV2 3' INV 1 LLJ SCALE J L1J + sc;-5 Sc-6 INV 3 3/32" = 1'-0" INV I LW CONDUIT BRIDGE SC INV 1 SC-7 INV 3 sc-,o ORIGINAL SIZE 24" X 36" 0 INV 1 SHEET SIZE ARCH "D" W sol 73 INV 2 c .2) D /,r 1�r Sc-6 sc INV 2 INV 3 D N D ti N NO. REVISION DATE U O U) N CU t� O C O O .Q (B O C N N © Copyright 2014 Renewable Energy Associates LLC.The N drawings,specifications and other documents related to this project are protected under law and contract. Reproduction of U these documents is authorized for the purpose of constructing, O maintaining and using this project. Use of these documents for aany other purpose is not permitted without Renewable Energy (D Associates'written authorization. C START DATE: 10/5/14 U E DRAWN BY: JS U) L ENGINEER: PH Q� U) APPROVED BY: RM U PROJECT NUMBER: A 14-02 REA N SHEET NO.: wooC 0 N I E047t O O C ^L LL