Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (2)
BUP2014- 00171 RECEIVED o JUL 0 2014 O CITYOFTWARD eUIIDIPdG131UISI0N CJ� CITY OF TIGARD REVMWED FOR CODE COMPLTANCB Approved: OTC-. : [ 1 Permit#-. Address CYC SGS ` O Suitt I By: Date: e r 1 DOFFICE COPY I LU 0 :D 10100 WASHINGTONSQUARE ROAD w 0 0 nI— � b WASHINGTON SQUARE � z 0 PORTLAND , OR 97223 STORE # 0770\1CID I N BT PROTOTYPE REMODEL Lir #1z § E21�LI o�Lw APPLICABLE CODES � W GENERAL NOTES FIRE DEPARTMENT NOTES Center INTERIOR SCOPE OF WORK: BUILDING: - 2010 OSSC, BASED ON THE 2009 IBC INCLUDES A DINING AREA IMPROVEMENT TO AN EXISTING RESTAURANT.THE EXISTING Q 1. DO NOT SCALE DRAWINGS-WRITTEN DIMENSIONS TAKE PRECEDENT. 1. PROVIDE NEW AND/OR RE-LOCATE EXTINGUISHERS PER LOCAL FIRE BUILDING ENVELOPE WILL REMAIN. NEW LIGHTING PACKAGE WILL BE INSTALLED. NEW W DEPARTMENT/AUTHORITY DIRECTION. SITE LOCATION MECHANICAL: - 2010 OMSC, BASED ON THE 2009 IMC FURNITURE, FLOOR FINISHES AND PAINT UPGRADES WILL BE INCLUDED. 0 I- 2. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY ARCHITECT OF RECORD AS SOON 2. ALL EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL. NO WORK WILL BE PERFORMED IN KITCHEN AND PREP AREAS. N AS POSSIBLE. ELECTRICAL: - 2011 OSSC, BASED ON THE NEC 2011 Gc Z 3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT SPECIAL EXTERIOR SCOPE OF WORK: 3. FOR BIDDING PURPOSES: WHERE CONFLICTS EXIST BETWEEN DRAWING DETAILS & KNOWLEDGE OR EFFORT (NO DEAD BOLTS, NO SLIDING BOLTS, ETC.) PLUMBING : - 2011 OSSC, BASED ON THE UPC 2009 EXISTING BUILDING FOOTPRINT TO REMAIN. EXISTING PAINT AND SIGNAGE NOT IN O SPECIFICATIONS,THE MORE STRINGENT SPECIFICATION SHALL APPLY. 04 W UI {- 4. AN OCCUPANT CONTENT SIGN SHALL BE POSTED IN EACH ASSEMBLY ROOM ACCESSIBILITY: - 2010 OSSC CHP.11 CONTRACT. 0 4. GENERAL CONTRACTOR (G.C.) IS RESPONSIBLE FOR ALL ASPECTS OF BUILDING HAVING AN OCCUPANT CONTENT OF 50 OR MORE. O •` _ 1`11 W ��/ CONSTRUCTION DELINEATED IN THESE DRAWINGS UNLESS SPECIFICALLY NOTED Z OTHERWISE. 5. MAINTAIN MIN. 44"AISLES TO EXIT OR PUBLIC WAY. N IL CODE DESCRIPTION CODE SECTION REQUIREMENTS - Q Q 0 6. IF REQUIRED, PROVIDE EXIT SIGNS ABOVE EXITS WITH MIN. 3/4"X 6" LETTERS LIGHTED ON 5. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON DRAWINGS FOR CONFLICTS : m LL CONTRASTING BACKGROUND, w PRIOR TO CONSTRUCTION.THE GENERAL CONTRACTOR WILL NOTIFY THE ARCHITECT OF USE GROUP CLASSIFICATION: A-3 0 z �/ ANY DISCREPANCIES. 7. EXIT SIGNS MUST BE INTERNALLY ILLUMINATED. BUILDING CONSTRUCTION TYPE: (EXISTING) V-N c>i) Q LU LLI CD J 6. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT AND/OR 8. IF REQUIRED, PROVIDE TWO (2) SEPARATE POWER SUPPLIES FOR EXIT SIGNS FIRE SPRINKLERS: SPRINKLERED EXISTING Q CD EXISTING LANDSCAPING OUTSIDE OF CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT CONFORMING TO CODE SECTION. r `:. Uj NO COST TO OWNER. " NUMBER OF STORIES-ALLOWED/ACTUAL: EXISTING NO CHANGE NOTE TO G.C: CD O O 9. PROVIDE EMERGENCY EXIT LIGHTING PROVIDING AN AVERAGE VALUE OF ONE " IT IS ASSUMED THAT THE G.C.SHALL PERFORM THE WORK AS ILLUSTRATED WITHIN THE IL 7. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND WORK AREAS SHALL BE LEFT IN FOOT CANDLE AT FLOOR LEVEL. BUILDING HEIGHT-ALLOWED /ACTUAL: 40'-0"/32'-0"EXIST. PERMITTED DRAWINGS.THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN THE EVENT THAT A CLEAN (BROOM) CONDITION DAILY. +' y ., „' BUILDING AREA: 7,415 S.F. EXISTING SITE CONDITIONS PREVENT THE WORK FROM BEING COMPLETED AS ILLUSTRATED HEREIN SO 10. ADDITIONAL EXIT SIGNS WILL BE PROVIDED AS/IF DIRECTED BY THE CITY "I THAT ANY MODIFICATIONS (IF NECESSARY) CAN BE MADE.ANY DEVIATIONS FROM THE 8. GENERAL CONTRACTOR SHALL PROVIDE A LIST OF SUBCONTRACTORS TO RED ROBIN INSPECTOR PERMITTED DRAWINGS WILL NOT BE ACCEPTED AND THE CONTRACTQR SHALL ° m - PATIO AREA: 308 S.F. EXISTING w. o GOURMET BURGERS. RECONFIGURE THE WORK AT HIS OWN EXPENSE AS REQUIRED TO BE IN CONFORMANCE ' o " 11. GENERAL CONTRACTOR RESPONSIBLE FOR SMOKE DENSITY RATING AND :. GROSS BUILDING AREA: 7,723 S.F. EXISTING WITH THE PERMITTED DOCUMENTS.THE ARCHITECT WILL NOT ACCEPT, CERTIFY ORSr " 9. GENERAL CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL RULES AND FLAME SPREAD RATING OF MATERIALS USED. DOCUMENT WORK DONE THAT DOES NOT CONFORM WITH THE PERMITTED DOCUMENTS FOR REGULATIONS CONCERNING LICENSING WHICH THE APPLICABLE GOVERNING "' ? V NUMBER OF EXITS- REQUIRED/ACTUAL: 2/3- EXISTING THE PURPOSES OF OBTAINING ANY TYPE OF MUNICIPAL APPROVAL DUE TO UNAUTHORIZED AUTHORITY MAY HAVE ADOPTED. 12. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT vaR,H REVISIONS. P . ;_ ,_ EXCEED AN END POINT FLAME SPREAD RATING OF 200 OR CLASS C. C -_ 13. DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. A AREA MAP 9 SCOPE O F WORK _- FIRE SPRINKLER SYSTEM: (G.C.TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT SIGNS, FIRE ALARM �} CALCULATED OCCUPANT LOAD: - - MUNICIPALITY WHEN MODIFYING EXISTING IF NECESSARY DUE TO NEW WORK) STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS SHALL NOT BE CL= CONCEALED BY DECORATIVE MATERIALS. SCALE: N.T.S. WAITING/STANDING AREA : (5 SF Per Person) 202 SF=41 PERSONS SCALE: NONE o > h 1. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR 14. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN AFLAME-RETARDANT WAITING BENCHES: (2LF Per Person) 168"= 7 PERSONS U <( n a REVIEW AND PERMIT AS NEEDED. CONDITION. CURRENT OWNER FURNISHED (B.O.) AND NOT IN DINING-TABLES &CHAIRS: (# OF SEATS) 113 PERSONS DRAWING SHEET # SHEET NAME 15. INSULATION SHALL BE INSTALLED TO MEET FLAME SPREAD AND SMOKE CONTRACT (N.LC.) ITEMS: a DINING-FIXED BOOTH: (2 LF Per Person) 136 PERSONS FIRE ALARM SYSTEM : (G.C.TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL DENSITY REQUIREMENTS PER LOCAL CODE. COVer Sheet MUNICIPALITY WHEN MODIFYING EXISTING IF NECESSARY TO TO NEW WORK) B O Items shown or noted as"B.O."or"By Owner"on the drawings and/or in the DINING-FIXED BANQUETTE: (18"Per Person) 49 PERSONS 16. G.C.TO PROVIDE AND POST OCCUPANT CONTENT SIGN NEAR FRONT DOOR. specifications shall be furnished by Owner to Contractor/subcontractor for installation by C1.0 COVER SHEET a 1. THE FIRE ALARM CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS PER LOCAL ORDINANCE REQUIREMENTS. Contractor/subcontractor as part of the construction contract. DINING-FIXED SEATS: (#OF SEATS) 6 PERSONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND PERMIT. Contractor/subcontractor shall receive, to the extent of unloading at the job site as a AS NEEDED. 17. EXIT SIGNAGE SHALL BE PROVIDED AND MAINTAINED FOR CORRIDORS AND required,store and be responsible to the extent of carrying necessary insurance to cover STORAGE/MECHANICAL: (300 SF Per Person) 1 PERSON Architecture AISLE WAYS LEADING TO EXITS IN ACCORDANCE WITH SECTION SIGNAGE SHALL STATE:"OBSTRUCTIONS, INCLUDING STORAGE,SHALL NOT BE PLACED IN THE items in case of theft, fire,loss, malicious damage and other miscellaneous damage. 2. THE FIRE ALARM SYSTEM IS REQUIRED TO BE AUDIBLE THROUGHOUT THE Refer to Section 01018 of the Building Specifications fora complete list of B.O. Items. KITCHEN+ EMPLOYEE MAX. PER SHIFT: 24 PERSONS D1.0 DEMOLITION PLAN BUILDING. ADDITIONAL ALARM DEVICES MAY BE REQUIRED UPON TESTING REQUIRED WIDTH OF AN EXIT OR EXIT PASSAGEWAY:' OF THE SYSTEM. (ONLY REQ. W HEN THERE ARE 100+ HEADS) OFFICE: (100 sf Per Person) 1 PERSON 18. FIRE DEPARTMENT FINAL INSPECTION REQUIRED.SCHEDULE INSPECTIONS Dl.l DEMOLITION CEILING PLAN Revisions 3. THE FIRE ALARM SYSTEM IS REQUIRED TO BE MONITORED BY AN TWO (2) DAYS IN ADVANCE OR PER AHJ. .I.0 Items shown or noted"(NIC)"on the drawings and/or in the specifications shall be BUILDING OCCUPANCY: 378 PERSONS ISSUE FOR SCOPE REVIEW APPROVED CENTRAL STATION. furnished and installed by Owner under separate contract, except as described A1.0 NOT USED 0 04/24/14 19. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE hereinafter. Refer to Section 01018 of the Building Specifications for a complete list of REQUIRED PLUMBING FIXTURES: LIQUIDS, FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS ISSUE FOR LANDLORD REVIEW 4. LOCATE FIRE ALARM CONTROL PANEL IN THE OFFICE ROOM THE N.I.C. Items. MATERIALS SHALL COMPLY WITH LOCAL FIRE CODE REGULATIONS. A2.0 FURNISHING PLAN 05/16/14 REQUIRED DUCT SMOKE DETECTORS SHALL BE TIED INTO THE BUILDING MEN'S LAVS- REQUIRED/PROVIDED 3 REQ'D. 3 EXISTING ISSUE F MONITORING SYSTEM. NOTE: B.O.and N.I.C. Items are noted through out the construction documents. If a A R PERMIT REVIEW 07/22/OO 20. FIRE BLOCKS SHALL OCCUR AT THE FOLLOWING LOCATIONS: discrepancy exists the specifications shall prevail. WOMEN'S LAVS-REQUIRED/PROVIDED 3 REQ'D. 3 EXISTING A2.1 REFLECTED CEILING PLAN v 5. EXISTING FIRE/ALARM SYSTEM TO BE MODIFIED BY G.C. A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURREDMEN'S TOILETS / URINALS- REQ. / PROVIDED 3 REQ'D. 2 WC/ 1 UR EXISTING 0 SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH A2.2 DECOR PLAN Q 6. IN THE EVENT THAT STROBE SIGNALING DEVICES ARE RELOCATED, G.C.TO CONFIRM VERTICAL AND HORIZONTAL. WOMEN'S TOILETS-REQUIRED/ PROVIDED 3 REQ'D. 3 WC EXISTING LOCATION IS APPROVED BY FIRE DEPARTMENT. B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL s SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. EMPLOYEE RESTROOMS 1 UNISEX REQ'D. 1 UNISEX EXISTING A2.3 FABRIC PLAN Q KEY NOTES LEGEND: 0 A3.0 NOT USED ACCESSIBILITY NOTES: 1.XX ITEMS NOTED AS"1 AX"ARE THE RESPONSIBILITY OF G.C. U.N.O.AND ARE -6 CONSIDERED PROJECT STANDARD SCOPE OF WORK. G.C.SHALL A3.1 NOT USED 1. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHER CIRCULATION SPACES SHALL HAVE 80"MINIMUM CLEAR HEADROOM. /� FIRE DEPARTMENT NOTES COORDINATE WITH RED ROBIN PM & RED ROBIN VENDERS. CODE REVIEW ( EXIST. BUILDING) 7 - Zs_ /1 2. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN L 2.XX ITEMS NOTED AS"2.XX"ARE THE RESPONSIBILITY OF G.C. U.N.O.THESE ITEMS A4.0 INTERIOR ELEVATIONS = ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS, SCALE: NONE ARE CONSIDERED DEFERRED MAINTENANCE ITEMS. ALL ITEMS NOTED SCALE: NONE a SHALL BE A SEPARATE BID FROM PROJECT STANDARD SCOPE. STAIRS,AND CURB RAMPS,SHALL BE STABLE, FIRM,AND SLIP-RESISTANT. A4.1 INTERIOR ELEVATIONS f�RC o SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION G.C.TO VERIFY WITH RED ROBIN PM IF CERTAIN ITEMS NOTED WILL HAVE 3. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN AN ALLOWANCE ALLOCATED PRIOR TO BID SUBMISSION. TENANT: ARCHITECT: A5.0 INTERIOR SECTIONS, DETAILS & DOOR/FRAME SCHEDULE hj " 27"AND 80"ABOVE THE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4' ("a JOHN A.CH1PhL Cf1_ INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES.OBJECTS SECTION TAG- INTERIOR/ 76 � j x 3.XX ITEMS NOTED AS"3.XX"ARE THE RESPONSIBILITY OF G.C.AS PART OF THE RED ROBIN GOURMET BURGERS CHIPMAN DESIGN ARCHITECTURE MOUNTED AT OR BELOW 27"ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT. SEE NOTED LINE AS O L EXTERIOR Electrical No.3653 y COLUMN XX FINISH TAG- CONSTRUCTION CONTRACT.THESE ITEMS ARE CONSIDERED ADA 6312 S. FIDDLERS GREEN CIRCLE 2700 SOUTH RIVER ROAD • DES pLA]NES,1L 0 x-x 4. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OFA SEE FINISH UPGRADES REQUIRED TO MEET LOCAL CODES.ALL ITEMS NOTED SHALL BE SUITE 200 NORTH SUITE 400 E1.1 ELECTRICAL FLOOR PLAN &NOTES WHITE FIGURE ON A BLUE BACKGROUND.THE BLUE SHALL BE EQUAL TO LEGEND A SEPARATE BID FROM PROJECT STANDARD SCOPE.G.C.TO VERIFY WITH GREENWOOD VILLAGE, CO 80111 DES PLAINES, IL 60018 COLOR NO. 15090 IN FEDERAL STANDARD 599b. RED ROBIN PM IF CERTAIN ITEMS NOTED WILL HAVE AN ALLOWANCE 847.298.6900 ALLOCATED PRIOR TO BID SUBMISSION. ATTN: ARIEL DELAO E2.1 ELECTRICAL SYMBOLS & NOTES } 5. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF CONTROLS OR DESIGN MANAGER: SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR e DETAIL TAG- MEP ENGINEER: E2.2 ELECTRICAL PANEL SCHEDULES & DETAILS x FABRIC TAG- CHRIS LASKY AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS SHALL NOT BE MORE SEE DWG.AS REVISION SEE FABRIC THAN 48"ABOVE THE FINISH FLOOR OR WORKING PLATFORM. x-x Q sas•x PHONE:303.846.5489 SCHNACKEL ENGINEERS 9 NOTED TAG LEGEND SUPPLEMENTAL DOCUMENTS: EMAIL:CLasky@redrobin.com 3035 S. 72ND STREET SUITE 101 Specifications IHEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- a Y PARED UNDER MY SUPERVISION AND THAT TO THE BEST 6. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE REFER TO SUPPLEMENTAL DOCUMENTS FOR DESIGN INTENT, INSTALLATION GUIDELINES, BEST OMAHA, NE 68124 OF MY KNOWLEDGE.THE SAME COMPLY WITH ALL RULES, LOCATED 48"A.F.F.,WORKING PLATFORM, GROUND SURFACE,OR SIDEWALK. JEFF KINDSFATER 402.391.7680 SP1.0 SPECIFICATIONS REGULATIONS AND ORDINANCES OF PORTLAND,OREGON PRACTICES,SOURCING,SHOP DRAWINGS, CUT SHEETS, &SPECIFICATIONS. RELATING TO STRUCTURES AND BUILDINGS. S PHONE:303.846.6179 7. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED,THEY SHALL ACTIVATE SUPPLEMENTAL #1 -MILLWORK EMAIL:jkindsfater@redrobin.com A MEANS OF WARNING FOR THE HEARING IMPAIRED. SUPPLEMENTAL#2-DECOR DECOR TAG- OWNER: X ELEVATION ELEVATION D•1 SEE DECOR ARCHITECT g TAG BENCHMARK O SUPPLEMENTAL #3-FURNISHINGS 8. STROBE SIGNALING DEVICES REQUIRED FOR THE HEARING IMPAIRED X LEGEND SUPPLEMENTAL#4-LIGHTING PROJECT MANAGER: RED ROBIN GOURMET BURGERS g SHALL BE STATE FIRE MARSHAL APPROVED AND LISTED. SUPPLEMENTAL#5-MATERIALS &FINISHES 6312 S. FIDDLERS GREEN CIRCLE Drawn By Checked By SUPPLEMENTAL #6-AUDIO/VISUAL QUALITY PROJECT MANAGEMENT, LLC SUITE 200 NORTH I]EPLAN KEYNOTE 1702 E.MCNAIR DRIVE GREENWOOD VILLAGE,CO 8011 1 Scale Date X TEMPE,AZ 85283 AS NOTED 05/16/14 MILLWORK MULTIPLE X t.XX (PROJECT SCOPE) TRACY FOLLMER X X ELEVATION M•3 TAG-SEE Job No. a A-1 TAG 2.XX (DEFERRED MAINT.) MILLWORK PHONE: 602.909.7544 X 3,)()( (ADA SCOPE) LEGEND EMAIL:TFOLLMER@QPMLLC.COM m p Sheet No. 9[E GENERAL NOTES3 DRAWING SYMBOL LEGEND 5 PROJECT RESPONSIBILITY MATRIX 6 REVISION LOG 8 PROJECT CONTACTS INDEX OF DRAWINGS C1 . 0 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE 1. SYMBOL DESCRIPTION • �� ,. I I ( EXISTING CONSTRUCTION TO REMAIN , 1 1 1 , 11 I ' ________ EXISTING CONSTRUCTION TO BE REMOVED II I I I . I I @ . "I .." I . PLAN NORTH : I i 1 I .:' I ! I i �\I j I I I i I I i i : ! I , , �,� .11 1 i i I I I i I i . . ____1.. --------- I--- _--_ ._ _ ._...-. _ ___ - _-.__- '- _•____.. _ 1__111...-. .. ___-__ --____. _ _.. _.._ 1111. ...... .._-" __- _- -_ _.._.._ .. .._ -- ___.- _.._. ___. �-.-._c.xs._ ...�_w_.-..._._ter- ._ _-.cam-�__,.:..u._.c _._.--_._.. ___ _ �-.�-.. _ -_c-�- .ri>-c -__ �- Y--�._. - -�-- ___ _--_ I I , _ --� - \ 2 DEMOLITION LEGEND I SCALE: NONE j j o�_�e I 4+- GENERAL DEMOLITION DEFINITIONS y-� t I - +-+- -�- +-'rye- (j -�- -1- \ ____ a i O �- 1 O I- y( I 0 i ( O !_ "L I!1 I- :`_ 1 0 a a D n-----IT! \ \.\� \ r --� -�. of-��, ,•r- or-a;, - U of-�;, \ \ DEFINITIONS: AS FOLLOWS: --1_1_11 _ --- - - - _ . ..- .. - -- - - ----- -. _ ---- ' - - -- - _ _. - -- - - _ J \ \ `. `1 -"" ` ' - - -- -- - - `. \ \ \\•. \ \ \` ` REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE INDICATED TO BE REINSTALLED, 1 I I I- E 1ji 11 i I! 11~ III !I 11 j I 1 1 i I I 1 I 1I ri i-i - 11I- 14 1 I " 1 I- \\ ..\ \ \ \ \ SALVAGED:OR TO REMAIN THE OWNER'S PROPERTY. I ;I I IIl III I II . I I!I Ill , ; I iII Iii II Iii I,i I11 III ! 11 ; III ill I \ \ rl�n IrT I ! I I 1 '' - ==I I I I �'' -'' I I n-'-n I` �,.'•..;,.I I I 11'--I'I '', REMOVE AND REINSTALL: REMOVE ITEMS INDICATED;CLEAN,SERVICE,AND OTHERWISE PREPARE THEM .4.. I ,1 .1 iI .,.I ! i . IL. II iia, Il ! I II I ::; I ! 11 I i l=11,-,11 =:I II 111 ;, ill .---.--. I I I 1.` C'11 1 1 I I 1 . 1 1 ,;Lin I /�' ". \\ \\., \ �\ FOR REUSE;STORE AND PROTECT AGAINST DAMAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. c 1 _ __ E I / , 1 k I I ......._- - _-___.:.. 111.1-...... ..- 1111.___.._ 1111 .. ....... ..... . _ _........__. _.. .__.__. . ..,. _ . ._ ___- .. ....... - _ _ - 1111 _I.._ 1111 1111. .. ...... .... +._. _.._ _. 1111.. 1 ( ._, 1 1 _- / . ---�+._. ._ _._�_ 1111 ._ _\_ � _,� ` ---....... . . ....1111._ .- ! + I l ! 1111. I I ...-. -, - 1....- I i . . _... lI l.._, _.'1, .,i- ! _ `` . j . 111 ..L...... I �I -111.1 .. 11'11_ I 1: ,1 1 ,,,�_ a .\,.�\ - \ \ \ \ C I I I 1 ..+..- � I I I �. _ t . I ' =1 :11 I L 'I i 1; (! ' Ii II ' I 11 - II I I 1 I ' I 11 1 \ \ \ \ \, N -__ 1 L ____ 111 � 111 , - __yL, . III _-. __I L_ -! _ ___ [ J 11 I Al _ _ L _ ___ L _ __ L $1 1 Il \ , \ \ \ \ \\`\ EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING _ i l \\\ \ t \ \'. DURING DEMOLITION. WHEN PERMITTED BY THE ARCHITECT,ITEMS MAY BE REMOVED TO A SUITABLE, 1 08 1.01 1.04 1.08 1.08 - %i \ \ \ \ \ \ PROTECTED STORAGE LOCATION DURING DEMOLITION AND THEN CLEANED AND REINSTALLED IN THEIR 1 04 1.01 1.04 1.01 1.04 1.01 1.04 1.01 `---' \ \ \ \ \\\ \\ \ ORIGINAL LOCATIONS. W Ll-� I 1.08 101 FAMILY DINING \ / \ \ \ \ J � I 1.01 \ 1.01 \ I _-- 1.01 105 1.05 , I 1.01 1.02 1.02 \`v�\ \ v \,,\ \ \ \ I - - 1.01 1.01 3 \ i �`/\ 7` /S meq` z` /S /S /S �y\ /}` �y\ /` \ 5 (�'y) .L _J /' /^\ ``\ \ /' '~` `\ / 1 m I � I 1 � �a� 1 v � 1 v� / / ` \ /' ♦`` / \ r \`\ / \\� 1\\ L V / ♦ / \\ -- L.- U---1 _- L- -U---1 -- L- -V--.1 // \\ /, \\ \ \ \ .. i ,i 11�J // \\ - I I I I I I I I I I I I I z J ,i \\ - ' b®-- I I 1 1 I I 1 I I I I I 1 I _ \ \\ 1 1,. \ � GENERAL DEMOLITION NOTES w � / \ , 1 I I I I I I I I I I 1 / \ / \ 7 -, - J // \\ q :I I I I I I I I I I I 1 ♦ / ♦ / \ {I,N,[\\ L __ 1.04 \\\ q \ \ �, :�', __ _ I I_.._. _ I_. _.L_... ,,,I-- - 1, ___ 1_ ..._I . ._L _,___L-- �Iry \ /( `\\� /o' \ `\`� ��' \� '\ \\ I . \ \ 1. DEMOLITION CONTRACTOR TO COORDINATE&REVIEW ALL CONSTRUCTION DOCUMENTS&DETERMINE Lu >p q �Aj >\\ q< 4bj i I L_____J L_________J L_____J L_________J L_____J L_________J i 1,\ /, ♦ /q"I � >\\\ p( Lj >\\ // 4L 1 pa r_=_== \ \ \' THE EXTENT OF DEMOLITION WORK&BECOME FAMILIAR WITH THEM THOROUGHLY BEFORE O 1 \�/ v v �/ IL I `` '�, J✓ \11J 4, I - - \ \` PERFORMING ANY DEMOLITION WORK BY THE ACT OF SUBMITTING A BID THE CONTRACTOR WILL BE -� 1.01 1'02 �� I I 1� `:_ r i \ \� �v , " 1,A \, v ,% \ DEEMED TO HAVE COMPLIED WITH THE FOREGOING.TO HAVE ACCEPTED SUCH CONDITIONS AND TO ; -- I ^ O\ / ^ \ 1.01 ---------I \ \( ` `` \\ HAVE MADE ALLOWANCES THEREFORE IN PREPARING HIS BID. ~ _ - \ '/ `` J \ ♦\ J ! ' r - \ , \\ `\ ` \ 2. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE OBSERVATION- - ----J; /��r ``\\ /�✓;/ ``\` 1.04r_i_7t 1.04 1.01 1.04 1.01 \ \ \ \ , \ \ \ f- j I r-----i r-------.,--i r-- -i _ __ ---r---------i_____r ---i r---------1 1 : -' • ` \ \ \ ` CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION&NOTIFY THIS -,.. - - , �\\ i� �_� i� I I 7"' 1 l' "" ' ' 1 I I I - `"'I _ , ._, \ \ '` `. `\ OFFICE IN CASE OF DISCREPANCIES BEFORE PROCEEDING.DEMOLITION IS TO BE EXECUTED SO AS NOT V) -. - - *___7 :: n\� �n A� ,gin I I I 1 I I I I I I I I 1 - r- 'moi, " r---r-r - r- r _ \ \\ ' •`,. \ `, TO DISTURB EXISTING STRUCTURAL&ROOFING SYSTEMS. O Q 1111.. 1111 { p , 4 ♦\ \ / \\ ,, I I I 1 I I I I I I I I I I 'lf ' I I r I: I { i t \ u �`� `\( \ / I I I 1 I I I I I I I I I I f " I I . I I g ' \ w< �i \'0 >w< 4, _...........I I I I I I I I I I I I '.. I : I I ii l € : I I I l I I { I \x• .I\.\1 �' a� �, L __ J L J L _ J L ___ __ J L __ J L __ J -1 I I: L- -1 1 I •, r '_ }h 1 1 -1c ` 1 1 3. CLEAN ALL EXCESS CONCRETE SPOTS,SOLID DEBRIS AND PAINT SPOTS FROM FLOOR.REMOVE ALL ._. r n---r r n r r n---r r I. ;h M,,L» I L_ � `Y I ,l- I 1 -•'I ;\ WAX,DIRT,GREASE,PAINTS AND ADHESIVES AS REQUIRED FOR NEW FLOOR FINISH INSTALLATION. m N I 1 t t_ �_J _J �_J J _1 J J _: .. _ - 1. I N I I 1.01 c== c cow == coo c = = c c c== .�. �.._�, 1111 ..:.- ... v _ {_ _ I /y� n /S`s♦ � \ \ r\ `I '` `'_'' 1. \ 4. SWEEP AND VACUUM THE FLOOR AFTER REMOVAL.DO NOT USE AN OIL BASED SWEEPING COMPOUND. I � I 2/,.\�� , / I I" N !'.\ \-\ -\ I '• ' " 1 ALL AREAS ARE TO BE CLEAN. � O - 1 � // `\ ). 1.01 1.01 1.05 1.01 1.01 \J , , I� - \ �/ I i l- �_/ �`,� - \ \,, , � � \ \; \ ` \ :; ::.1 \ 5: G.C.TO REMOVE ALL EXISTING WALL ARTWORK AND 3D DECOR. PATCH AND REPAIR EXISTING WALL TO w .- �^ r� 1.11 1.13 , A \ v A A V\ v, ' \. A ti \ RECEIVE NEW PAINT FINISH. '.i II, .��1.011 `vJ /r c= 1.02 ,_... 1111._._. .__-______ TYP, ::1v�vv\v,.v v v -�VI "I A vV A , vA v �O;;,i� 4 ---- ---� \ w "I L ' "' \, " A V 'y V A �VI 6. RELOCATE EXISTING SPEAKERS,FIRE STROBES,EMERGENCY LIGHTS,AND EXIT LIGHTS AS NECESSARY � �� w 102 �I 3 / J - / v �' i 1 I 1 fL� /q / ' \ �\ `------- J 1 04 ` FOR NEW WORK.REFER TO ELECTRICAL DRAWINGS. } - \ ``.\ \\\'\. \\\ \`\;\ \\ t 1 I \' ' CSO ' /. �� 1 \ \ \\ ` I \ - 7. TV'S THAT MEET CURRENT SPEC ARE TO REMAIN.COORDINATE WITH AN VENDOR&PROJECT MANAGER. no �~ w ' / 1 ; I o. r---------\ V A '/. y N V 1 V\\?; `'`,; 11 . Ii� k 1 - - �. I ! v\ `\ Vv \ 1. 1- 1.04 1, 1 - __ 1.01 I � , \ \ " _ _ _ 1.04 r--_- ---- r - ->i i ` \ \ \ \ \ , \ \ `I J 11 j I �v / , I - I `I I 1« I A ��V A` � ; A V `l, y W ?' 1111... .•' ''=°� -.. \�_- _ '�/ I I I : I 1� t \`\ .A ',\ guy: ''y ` ,� \ II \\ z \V % I I I I I I V , , ,. \, `tf. r:: If I \v. i' 1.01 I _ '.1 I 1 1.01 : I I I `vV A \, `\\\� Icy\�\ `v. , .v y v A. \ '`v v .,\V ,v \ ,� \ \`\. �,. �.. •�--"� % - I -- A " .1.1..1..1... _.-_------- _ ......._. .... .-------- - __1111..,_ _.. _ __ __.___.._ . .....____ A � � -�� ^` =5 _ _.-__U -� I 1 I AV y y \ v _ ` \. wv v v A ., 'V A v A 'i \ A �/ \w��--J \` \ \ I- A I rJ 1 `.\ \�;\ �`,- - \ '4\ i \\\\\ .\.\\�\ \\\ \ \\\ \ �IRI I,III `\\ '\ \ (`') L.L /\\ iii ,_;. ------- 1 \ , \ \\f t \ \ \ \\ \ \`\ \ I 1 \ N ' >\ ' \� `` \\ \ \ GENERAL DEMOLITION NOTES O c� N w 1 I 1.15 `\�` P-_-_ - - __-•s _-�, I `I , `._\\� 'i� _-`�_7J i . \ \ \ \\\ \ \\\\ ,.\ \\\ \ \�\, I'�' \ \\ `4 1.17 n n `\ \ \ - - -1_ n--n I 1 �\ \ ` l � \i.\\ \ \ \\ \ \ . 1. \,\ '\\ ` \ \\ 1 ' i - Oh z JI,,. I L- - \ \ \ \._ .: \ \ \` SCALE: NONE O �/ 1.08 c-€ L� \ I - 1 �� I \ \ _ \ \ \ \ \ i N LL ----------------- 1........., .. _; _. L 1111/...... .. .... :- ._\ \ \.-.-. :1111 7 �,. 'I.,,..1j.. \\`.. \ •n _- - _ C'r12, , I , '! \ ht,\ �I.__.t{I " \ -.a ..`,.`., \ ,,\, ., ,.\,\", h, �JF \\\\\` \ I 4 %..::a,. .1 L Q t , 1 I'1 -U --._..._.�. \ ':__ "- \ ,\ it = . m Ci _ V <,--� v k g 1.02 1 ;. V 1 C ° \ \ v h \ tT + ED\l 1 -- � �� I �( 1 \ \\ R, \ 1 1.XX (PROJECT SCOPE): ' { �\ r------� 1 __ 1.08 t \ 1 I \\ �\ - ' `,-� \ `\ \ \ \. _ TI\ ''\ \ \ Z 1 LL _______ ---_ ____-- - 1\ ,c . _ ___ O `. \.. ._; 3 r --7 1.06 r- - \ 1 \ I \\ ;\ '`. \ ,' \ \\, \ \ \ -_ ! \ \ ` K1 ` ,� EXISTING TABLE TOP TO BE REMOVED AND EXISTING PEDESTAL BASE TO REMAIN FOR � N Q O w VESTIBULE i r----.1 I LOBBY 1ry, �I I 1 I --- _ r \ \\\ X'�\��\` \ \ \ \ � :; 1.01 RE-USE.ALL EXISTING CHAIRS TO BE REMOVED.REFER TO FURNISHING PLAN FOR EXTENTS J._.__ ,1 .1_ - .11 _«"`':,. : ' _-_.--. }._.._.....- .____- .. 1111 . ..- _ .--. I I X I I 1I _`` --T J, 1 -, : " , 1 1 ., \ \ '',\ 1!, Ir >< \\ \ a - ''._. \. \ '1. \ � GI 101 I I r \ I 1 102 1 / 1 11:11.. , ` `.x ' :,`\ `:\`'_, \-:' I \ \.\\•.. '`:dalI 1 J \ JJ , \ ` . 4 , OF NEW TABLE TOPS AND CHAIRS. 0 O\�`,,.�- ^'' \ \ \`IP\..., \.�.-.- 1111- ''\ .: ., \ y \ - LLJ, �: I _J I ♦� 11.111 i l.ol I Ir" „`\ \ 1� « ., ',111 �'+.�.'. \ `\ \ \ 1. I~ �1 O w V J -__ C� - i 1 1 \ l \ \ \ \! l , h: _`` \ \ \' 1.02 REMOVE EXISTING BOOTH AND TABLE SET. REPAIR FLOOR FINISH IF NECESSARY. � � Q 1.10 ��,- ! I I I r I \ h,`\ �l{i}{ 1.\\ ' - , \ \\\\\ , 'h ' �, , I\ .I \\ \ '\I T ?'I,.\. \ '`..,,\\� �,`�,\ "�""" ', I' �\ + \ \\ \ '\ `\i. .n I" "' i `\\\',.I`1. l,+''l.\11 ' I --- J I \,yI '. \ \ - 1.03 EXISTING LOW WALL PARTITION TO BE REMOVED. 1.07 I � �/ 1 ._ ,- x , v \ \ \, \ t \ - -'� \ -.1111 1111 .. 1111__-_ - ___ ._. _ -1.1.1.1__._ __ -.1--1 - .1.1.1.1 - -- �'.. `, I- \ \ �'.. .... l .R _q '�=sn;, n. \\\ 9__ _1\i ----. ._ ___..... , ( ,/ - L - D AND BACKS 1111. \ i.' \ ! \ \~- \\ " -- \ R 1X - �__ `_ _.�_� , y I \.I \ i-..• \ €\1 t\} K,,. \ \ \i�M : 1 04 EXISTING BOOTH SET TO REMAIN BOOTH BACKS FABRIC IS TO BE REMOVE c 1.04 1 i \ \\ j\ \ `,I ; t ` \ ` c \! RE-UPHOLSTERED.REFER TO FURNISHING PLAN FOR NEW FABRIC SPEC. ^ o 11 1111 ':I 11 -"i\ ,U�_ �� �L---J ' / \ 1 '�-�� I -. ' \��� ` . `\ - _•\-� Y��4\�. 1 \ `'+ v I ` 1.05 EXISTING BANQUETTE BACK FABRIC TO BE REMOVED AND RE-UPHOLSTERED oU) - ~_ 'o 1 I r� nI / - 'r --- ,' I I`; NOT IN SCOPE OF WORK 4 7+ " r ' ' `r "', \ \ '' ,I tU v ^ a U 1.14 I .1.1.1.1 5 t / ------ y ✓ _----_--_-__: I 1 ,\ '1 { {` 1\ ` EXISTING BUILT-IN WAIT BENCH TO BE REMOVED.REPAIR WALL AND FLOORING AS '' v ° m -1� 1.06 I p � , 1��- - -�- I i i I 1 11. \ `r; , :, ; 1.06 NECESSARY. .� o_ -_ - L-------------A 1.01 I I ; . 1 , ` _ \ 1 - -- ---- I _. ' � % i -o I I 1.02 I I I \ I I 1 \ : . '\ ._ \ \ '' \ �,` \: \ I\ \ `I. \ ` \ \ t Iw��- - 4 ,\ T\_ Q1 Y y w \ 1 \ \; \ \ \ EXISTING IN FLOOR TV TO BE REMOVED AND ALL ASSOCIATED COMPONENTS ALL a , I ' GATHERING DINING �I I 1 �� ` r ` •, \ \ ``� "�,,' - w ` t `\\ `\ \ ' I �L \( 1.07 ELECTRICAL TO BE CAPPED OFF. REMOVE SURROUNDING TILES BACK TO GROUT JOINTS. = .`-m 11 t_____________________'I ' I I I I \` , \ \.` "\ \\ `+ ` 'n' \ EXISTING OPENING TO BE CONCRETE FILLED AND FINISHED TO MATCH EXISTING FLOORING. Q. o° 1 4 - .1 .1.1.1 \. � \ \ \ \ \ \ ' I, , - . ,.. o o -- \ \\ \ -1,1.11 P ,,;:,,.�.� - -_ - 1 \ Ii, 'E \... .:..,,ti- . ...,, '�`" .a `'.'' \ 1 \ y, ` , \ r\ \ kF .N, 0. u y n -- 1 1 I '.. �I, I __.._....... `•,. /,S n @\ /9 n , , d* h'--may 'J` 1 - -- - --- 1 ,`1,,111- \ ` '' \\ . . 7 !I -.' )/, \\( A )/r o f / ♦ \\ J 1� �1 / 1 \ k_„ ! \ \ \ \, \ \ \\ \' \ \ \ \ ,}. 1 ;v 1.08 EXISTING MILLWORK COLUMN ENCLOSURE TO BE REMOVED.REFER TO DETAIL ON A5.0. +- n y m :. 1.13 /. \ > r \ / 1 1 -- I . \, \ : / a a :I I ter/ O ,i O � ILS-T--�-T-2� 1.04 1 \ \1\ x€ •, . . . �, I` * \: T ,"#, '1. '; r \ \ .\ \ .y "\'>'q,•\ .\ \ I. 1 1 A:\I \ V Q j, o. ! ,I) - TYP. ,r \ r \\ I ` ' \ _ --- " � \'\ � \'\ , \. " \ °n J _'„ C 4;i , ' \. \ ` \ . \. I 1.09 EXISTING BAR STOOLS TO BE REMOVED. --- -'---- i \ ,I; /� .` �i ♦� �r \� I ; tr 1.1.11... ' �I. \ .A: ,._. �,\ .: {i4s. . ;i '\\ \ x.\' . `.lid., _ \ , 4 , / v vv q y r I 1 '`` - ,,.I /. A v / .1:111 #t .11� v'iv ♦ : 1 V v 0C\ v I �( I I v / ♦ / L- --- l- - r___-----�v i I I , v. v` 1 A . ? v 1 t '`• %/ y lily v'\ 'k V EXISTING LIBERTY STATUE AND MILLWORK BASE TO BE REMOVED.PATCH AND REPAIR ;,.I i'I!l `vy '' ``i It ,t` / --------- I__. --- I , 1 .Ir Ai1...1 ,,'-, ',� 1., iI. \;1,; ', v ' ,� - f y, v VA „ A: 1.10 I I �v , v , ( -- - 1 1 �t. WALLS AND FLOOR TO MATCH ADJACENT FINISHES. 1 I , v� w of v'� vv �i O� tery r I I I I + I I vy'� ,v �v « ,� IV�vv 'v - v k,'Ir 'Y 1~ I' vI _ V , 'i\ © I - 1- . � S -' '., :+ I 1.01 I ',I V \ 1 A,V - ..- .. ., II .'. A 11, 1 y \\ • .-.{ I I . .-... \ , •+,�11\11._ : \ 1.04 1.02 1.02 1.02 " �' \ :n I \', \\ \, i,,,,,' i- ,I;' ': `, \ REMOVE EXISTING CAROUSEL HORSE.PATCH AND REPAIR EXISTING TRIM CAP.FINISH TO ,;, \ r I_._. .. 1.',,.__ - I 1.01 I 1� ;, \ ``, N .......- \ „ a \ ll IT .-..\ I',dl ! \ \ ` +\ « ''1 \'" ;1J d• \ 1.11 a \ / I I I 1 \ f y \ MATCH EXISTING. i 1 4' \ ® B' \ 0 9" �t .Y L_-- _ _7Li= i 1 \ �' ,t'-'`,'_' \ \ `\ ,\ `.._1 .IN -'TA1I,I 1 �,;'` i `i \\, 1.01 >i..\\ >�. \\ � , . 1.04 _ __. I I i - ..... -.`'\ \ ` 1l*_ \�`,'`\\ \,•w .. I, \ \ ';, L .* ' .fit• ",,_. \ , C,`. // /,. \\ / \ I 1 ..,i \ , `. - - ..I;L.: 1 \ \ ' r% h Yom: l \!I�\ , ..,\ . ^ \ , r - \ r \` 7 \ ' \`� I `,.\ \ 1 . u \ \ . t " I \, \' ` \- \ \ \ ', \ v EXISTING MURAL GRAPHIC TO BE REMOVED.PATCH/REPAIR AND SKIM COAT ENTIRE SOFFIT I r L_______ \ ! : \ \ "i\ `\ TO RECEIVE NEW PAINT FINISH. � 11 `,� 4/ ♦> 1 / \� 1. I 1.01 ='� _ I ,. _ -.\ \ `\ �� , - \� - \ ` \ . \ - \ \ \ 1` 1.04 \\� ,� \\\ ,� / I \ \ \ y ( \f\, L \ \, \ \ , \ \ \\` \ I REMOVE ALL HALF WALL BRASS/GLASS DIVIDERS THROUGHOUT ENTIRE RESTAURANT. _-- _ (/ ) ' ), / \ �( ,\, , I I 5 \ \. \ \ \ „X,. { J , \ T\ \\ \ \\ \ ` \ 1.13 REPAIR EXISTING TRIM CAP.FINISH TO MATCH EXISTING. 2 C�_ / \N /A/ .�y/ C��,_ / \\�\ _�� l;®� \,C/ ,t , �j I �,, \� , � '`. \ \ , \ \ \ \ , I', _\ \`'' 4 Revisions r - '__-W-.-. a\� G \S� �i \s' � - ._. \•`. ,\„ \\\`'` I, I ..,:I '' `..\ nY`l`\ \`.. \ ,\\ '.I`I. '. \ ''\\\ `",::,\,lI`\ , \\\.. ,� 'i !: r L------------------J \ n o I r 1 1.13 \\', \\,' "''I \ u ryf , iI \ ` Py xr�YX\p k\:, r EXISTING WAINSCOTING TO BE REMOVED.PATCH REPAIR AND SKIM COAT WALL.PREP TO ISSUE FOR SCOPE REVIEW E TYP. :,..,� \ \ ". c .ti.-...! '` ` �,, �' .'�'- .i ,; \ \\ EI =:' 'r,y,''.ye I. ';` "n . f'1r + ,'L 1.14 1.01 \ v, ,`,1 I� \ ,1 xh 4 i� ,:,, `,\ \ \ \ "•. ,,.x \fv'i I 1 I , - \\ \ ° \ \ I ,� ISa 15 L. t RECEIVE NEW LOBBY WALL ART. EXISTING BASE TO REMAIN. 04/24/14 13 I I , _ 1 \.` \ \ A kt... LANDLORD REVIEW ---------1 1.02 1.18 1.08 1.02 1.02 \ k \ \ 1, Y \ :\ ' I „� \`\ \ ..1. . \ \ \ T�+ -1\1 ," -o- ta. a . �sL J \ ISSUE FOR 1 03 \ \ \ ` \ \ 1 `\ I \' \\\ \ \ 1.15 EXISTING WAITING BENCH TO REMAIN 05/16/14 PERMIT REVIEW W ISSUE FOR syr - --- -----�F.= --- - _ __= ri r j ,� \ ', \ \ \ 07/22/14 c •' a lu� I j n ,- c- �� I j �ml� -I I- �I I "._ .1111_ _. 1.1.11_ \ \ : EXISTING HANGING GLASS RACK TO BE REMOVED.PATCH AND REPAIR CEILING ABOVE AS , .. : . - n • _ .:- _ II I 1111 I t .__ I 1 I i "i. \ \ tl 1,.111 :y.. , \ i \ - ... _ 1111 ... --_ \ 1.16 _"u„___ ,.111.1 »._. _.__„__ . .1 ZL " t 1 1-I 1 I I-1 1 1 1 I-I 4 \_. _. ,s:.. x ,, 1 1.11.\,. NECESSARY TO MATCH ADJACENT. AUd „�,,. �� .> _, . u 111�1J III III UI `,_ 1 _: , III III 1111 I I I I �I II 1.13 1 . `` .` , v v ` v. v ` v v\ \ - ss p #" 4(x- II X1'-1 I I - �'1`r. I I L,I,J ,,--., :..-.11.11 : v A \V •:v •V A N \ ________ hrl ,.-_ _......_.,._._ .,.., ,v, `` \ , , \ V , A ..,1111[ ,f i. ... _ ,.., r,,,r.,•,1,--,� ut...v_. II B BI II 11 TYR , a I- a�a-- s.a==__===_.0. �a= !. A - 1.17 ALL MENU BOXES AND COASTERS TO BE REMOVED. PATCH&REPAIR DAMAGED WAINSCOT. :. y \ `:= (ltd I I �n `}-------p------- }-------�ti-••-----�}-------1}___ ----_ ---,v; ll '; ' HALL ,., A V ',..., A, A, •`. \ \ A.,\ ^ \.., A,A , ,\,v , A AVA. �.. ,._ _ 111 I I pl ___- ----- � 1 v,._,i ,! A v, ` *. A V Av A A V \ `, J �' 'I- r1 -I' ' -I' fl � 1 v v v , ` v \y U I I U m I°,� 1n m 1p u A \ yA V , , A v REMOVE RED BIRD SCULPTURE.PATCH AND REPAIR EXISTING TRIM CAP.FINISH TO MATCH ,' J. y -----J 11" I I I--II'1-1 I I III I I ��I'-1 f U M _ 106 '\ \ \, \\ ` \€ - \\ `\\\.\ \\ \\\\ \ Q r I 1.08 LIJ III III LI .II1 III I 'I III I' I IIl iI ,11 I I I I LI, 1. I 1 1.03 M ui� i I fii l i i f lI1 i 1 f iii 1 f (p ii I \ \ .1\ \� \ 1 \\\ \. J EXISTING. 1.02 ��4 J� __�L i�J,l4 J�_ __�L }1„� J�__ __�L iJyLL� J = ___ L fl�� r4 \,\ ,N \ \ \`\ \ l , I \ \\\,`\ 1.19 REMOVE FOOT RAIL AT BAR. REPAIR OR REPLACE TILE AS NECESSARY TO MATCH EXISTING. 1 1.03 1 \` VA , 'N Rl;x \ - / , 7^ Lr--rJ c-o / \ �\ (,/ 4 \ \ \ \. \ \\\ \ I\ �.\` �`l \ 1 ;".., \,, 7 _ 2`t _ / 1 1.02 1.02 1.02 1.02 '� ^\ /`o` \.1.11.1 \ \ \\ k z c_o i___i ? - \< I ii \ \\ \\ \_ \ �\� ,I I 1 , "' 2.XX (DEFERRED MAINTENANCE): IT' , 1.os BAR / LOUNGE _ I (\ \ \ \ - h\\ I \\\' ,. ` r 1 I I MEi�- t=- \ \ r i 1 I <� ,9 � 103 „� r. WOMEN _ J . Zv v vy _ A.1 J �.� 2.01 ��� 1---L 1 I vy . /� 1.19 1.191 108 \ � -V V`: A�`v \\\ �' - C7�� ,� \\ q 1__-. ! 1 __{ 1 111!.1-I---1-.1__ I !..1.111... 1. ... __-_. .. __. _ ---__. _ ., I I L ---rJ `��\'.r r, \ ------ _L_-: a- 107 a � �.,.- -- \, �`. \\'\ *� I i ! C� l N Vj =----- -- I'll-===_ -=_ -=_ =_ ===11------ ¢' <,, OHN A CHIPMA �Cfl a I ® \ ' 4 _-. __1 1_.1.1_ .,_. ___�. ._ _. \\\ \ '\\ n I -J `\� v / - -I,_ - \: , ti<:'. \\\ \ \ \ \\ 1 3 L No.3653 y t J c-o d: T- r 1.02 , ; i YY a TYr .,, h\,. ,' .._..ta: \ `"- .n I �' `�\ ,h. ` \ ._L.,; __ - __.._.,J 1.02 \ -- y :� 1 i, , il L..-.. ,. <, i l^ '`,1i CL \_. \ \;,1111 I\ \ 1 1 11 I -J ;,. .,..' "� \ \ '\ '1 :\ \\`'\ c a „. . DES PLAIIJES,IL • c.o c=� _�, ` � :aal ' 1' q - 1111.-1111 _�1 \ •-,-a ':.:r _ _ '.•\\ \\ \,� \ s\ __lam.- _ __- ____+. I a=_ �/,`vv I l{I " v _ , \ \ y A v V AVS v A' V . v A - _I `< y 1 ---L , .11.1.1 y v ` I : I q ``� ( Lill . r , \v \ \% VA \: I '\ r1---. l 1 I riri `� I' rel '.�:?,. i t I -_ A , ' \ 9 _- ------ -- -- -- - -- - _...... .. __... I-- I I 1 �_ >) J 1,16 1.16 r i'� \ I ,._ I I 1 gin♦.' /ri \....1 : '\1111_../ ._. 5..,. \ ', r r N: J.,... \� �\ \` r _. .1111. ._,K__'__ `\:-�.:_. - -y - \, • \ \ \ ._. I1[ \ \ 1 1 L'r---rJ `� \\ ', it 1 , .i. ._ i,1,_ r 1111. , ..-s :a, Y ... -.._-.111.1_-_ .. , '� m \ ��1.�1 ! vi ... .I a Iii `'^__ \, `� iJ "I' ""'_ "' 1 ""'" ` - - 1 HEREBY CERTIFY THAT THESE PLANS HAVEBEEN PRE- , Lj {� l y- ,v L. '.1.1. A 1111.. .. .. ., I o t- .----- :__ - PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, ,c __ __ _ -. 111.1 .1.1.1.1-----. . 1.__.11-1.-- __ _ _-_____. __ __ __. .__ __ _ _ _ _t-_- -1 11___ _ _-_ ._ -__.-_. _ _ _. .-_..__ _ ___.- __ __ _ .. _ _._.___._ _ ___ .. _.......__ _ -_ _ ....... ._.. __ __ ._ _�_ -.1.1.1___ _ .1.1.1.1 _ 111.1-__- _ -_ -.-1.1.1.1.._ _. _ _ - -_ .-_- _ - __. _. -___ _ _ __ - - - _ _ _ _ - __ _ _ - -7--,_ __ _1 111.. REGULATIONS AND ORDINANCES OF PORTLAND,OREGON '/% RELATING TO STRUCTURES AND BUILDINGS. 1 ' I i tt ' 1, 11 I I I ARCHITECT I I I i I ! Drawn By Checked By N Scale Date TJ 05/16/14 Job No. 11 p Sheet No. DEMOLITION PLAN 4 DEMOLITION KEY NOTES D1 . O o SCALE: 1/4"= 1'-O" SCALE: NONE III Ei I II IilI1111llll'1 II SYMBOL DESCRIPTION _. _ EXISTING CONSTRUCTION TO REMAIN ('� EXISTING CONSTRUCTION TO BE REMOVED �i`�_1 - (i Q-1) PLAN NORTH � O \\� -J -- --- ----- --- -- ..--- --- --- - --- - -- __ -- "- - _- -- ----- --- --- - --------- - ---------- .------, -._, __ .. _.____-- - -- - ---- -- -- _ - --- - ------- ----- --... -_._- ,--. _ __.. -- _-_ -._,_ __ -.__.- __.... _. __, __a-_ 1 yq. 1 yT.... .. ,7 i ♦ �__.._._._.. r'I . l_ 17 ai-_. :r '1 '' ii i� II ,�;ff.1 _,I -f'---___-___-. C 1 I , , II ' / 1 !1 n +, ♦\\ ! ! II l.Ii ! iii I' _ II - - 'll __-_ II 1111111111111111i 'r- _;+I II 11 ' .\ \ `�/ I I + ! \ \ -{.. `- ++ T }7j ".-1, J._ {'T F 1 gR' -_... +r"._ -. 'I_ .._ - 4 .- 17 '.-1.... , /,�/ \ \ 1 IT-- ,. . ,.,rr...:..#i=r,,,,..u.s.-:_::' ., �:: dl ., luk-'- .._:I;m. Imo, '..r- r,. :. ... II � .,..,...,. 1'ilr...--__-, - ,._.' k.r.:.._ ,� I I / ill \ .,-0..11 ,, u,. 9. r.u.,._ , I 2 DEMOLITION LEGEND - i v + i i I it I "Il ii - {II ;it; !III i, I / I I i 1 '``• • 1. i ! ! 01 11 �: 1 Ii .I YI, -:! ;:11 II j1, !! ; il I /// I ! i t \\\ \\ ! 1 _ i{ I! i i it :.i, ' 1 1 !� 11 II , , 1 ! . , i I +, i I .! -1 i :1 .I _, Ii n '111 II ,111 I . / I I SCALE: NONE i I ♦ \ '. I I I r-- __4I-___ _ ._-__ ._-.-- - __ .._____ ___-______._4L______ ll _.___. __ _ _ __ _ 1 -__._@{ _ J , I I ` I I ! I tl__i _I+__________ ;t 1___,____.._.-__.,'t__ .,1! - --___._ yr_________I 1 ______- r}.-.-... i i _ _ +{_____._--_ ! I _ __11___ i i -' 1 1 1 � i ----- �- - ------ W II 1 `\ \ 1 II 11 ,III 1 I;,i II ;;,I II IB 11 ;III II ii 11 I ,'I 11 1 \ . { r I 1 I!I II 'i ;;ii II 11 II Ilii 11 III it ii 11 I 1 `. `\\ 1 + , ; i` r�* r:\ r ; !i 'it Ii r'I 11 It 'I ��� ',II --. 4{-- ._.......... �{.-- ---'--._.-..._ i \ \ ,'� 11 GENERAL DEMOLITION DEFINITIONS -- --..__._ _ € I - ' r - r -- Wit . .._::._ J. . `d- a _ _ -` -__ -_•_ __--� -;, --__ -- "� =i /:; DEFINITIONS: AS FOLLOWS: l., T \ \ \ _ ,�- \ \ / - I - - _ ` '\ \\\I \\ \, \ REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE INDICATED TO BE REINSTALLED, ! I I � - 11 i \ \. \ \'`\ \\ \ ' ,}' ,a'' SALVAGED,OR TO REMAIN THE OWNER'S PROPERTY. I ! 11 I V '� i \ ! V 1� �1 TF; V (I � I ' \ I & A I i A I \ / I { a� \ 1 _ © \ \\ REMOVE AND REINSTALL: REMOVE ITEMS INDICATED;CLEAN,SERVICE,AND OTHERWISE PREPARE THEM -____. � -- I ; \C_ �!Ic_ y f C > r _y \ `\ \ \� FOR REUSE;STORE AND PROTECT AGAINST DAMAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. , ..- - I \ - - -- 1 s i , \` \ \\ EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING 1r ; � 1 � ` I I I �-1 I— "\_I � , J I \ \ DURING DEMOLITION. WHEN PERMITTED BY THE ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, I i , 1.01 I 1.01 i 1.01 I 1.01 I 1,01 ( I ( 1.01 I 1.01 I 1.01 ( \ \\ A \ y A� PROTECTED STORAGE LOCATION DURING DEMOLITION AND THEN CLEANED AND REINSTALLED IN THEIR _ - --I I -7 -- - - I - ---- _.. 1 -- - - -------- -i --- - - - (- ���- - --- - ` ORIGINAL LOCATIONS. w 02 1.01 \ \ \ - 1 I \ \ \ ! .: r 1:: FAMILY DINING I i � I - I \S\ ' 4 I \ �\ Q i I I I \ \ \ ..,, ,< �.... x ......,.,-.",-I---� . ,....... ......_.. _... 105 j-_................. . .....-,I_ _ --- _ I I � 1 I � \ \ \, O � �, C, I I ., �, ! l 1.01 .E 1 I I ! LS' I ; i 1.01 i I vA \\ '' \.. A \` V 1 \ ' ...- \ , A , _ .,...--- I / - ---... . - ' - -... 4----- __4 -- ,. --- - � / GENERAL DEMOLITION NOTES l lG I \ \\ \\ \ ,- _. .. I I I Gam ; I CW Q3,911 . FW I I CW CW i W \ \ \ \ \ \ \"I 0 r) I (� /) 1.01 \ \ `` \ \ 1. DEMOLITION CONTRACTOR TO COORDINATE&REVIEW ALL CONSTRUCTION DOCUMENTS&DETERMINE I _\_ _ t_--, _ \ \•\'," \ \ \ \'.�\ N WORK&BECOME FAMILIAR WITH THEM THOROUGHLY BEFORE THE EXTENT OF DEMOLITION Lu O _ - -�, \ 'i A j \'\\ \ \, -- \ `\ \ \\ \, PERFORMING ANY DEMOLITION WORK.BY THE ACT OF SUBMITTING A BID,THE CONTRACTOR WILL BE � i 109 / 1.01 \ / / 1 \ , \\ \ \ I 1.04 � J -L � / L \ I �fl 1.04 fl 1.01 1.01 \'r \>/ \ I \\ \ \ \ DEEMED TO HAVE COMPLIED WITH THE FOREGOING.TO HAVE ACCEPTED SUCH CONDIT ONS AND TO F,.../�_r -_ _...1.I _. ;I. 1 _.-. �.____� �-..._ �. .____ ___. _ -1 1-11 - \.� \ \- \\`,, \ - , \ \ `\' \\\ HAVE MADE ALLOWANCES THEREFORE IN PREPARING HIS BID. ~ `-' ti __ ----- i u � �_eE/ I � 11 \ \\ \ r\ r-=-Er-�°�Er--mss--.{res.�raa I{r�_m mm{�==fir---Er- 114 1.01 i ; i i 1.01 \ \\ \ \ ``, \ \ 2. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE OBSERVATION_ - Z ; 3 I 1 01 , \ \ \\ \ ` \\ i 1 \\ \ \ \ \ CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION&NOTIFY THIS t 'J I r► �\` . \,\ �'•\\\', 1' \ \\\ OFFICE IN CASE OF DISCREPANCIES BEFORE PROCEEDING.DEMOLITION IS TO BE EXECUTED SO AS NOT O J m� m T� T� T� F r1 1 \ \\ \ \ `\ ` \ TO DISTURB EXISTING STRUCTURAL&ROOFING SYSTEMS. Q / - - _ u-� u- ,yam o- u- u- , of h I + % \ = I \ \ II - •. \ i;!' -- " -- --- - - -- ---"'-- - -- - - <'iIf` '� � . y, .., ! r__yl s°- r ` . \ ` \ ` 11, \ 3. CLEAN ALL EXCESS CONCRETE SPOTS,SOLID DEBRIS AND PAINT SPOTS FROM FLOOR.REMOVE ALL 11 1i1 1,0, ! ,� .' � ! "� I WAX,DIRT,GREASE,PAINTS AND ADHESIVES AS REQUIRED FOR NEW FLOOR FINISH INSTALLATION. m � � N ,, I .' I 1. - -;. Z a Ill :.-..-... ______...__ '------ ---'- -_..__'__-__'1__..___-- _ . _ -_ _. _ :....... ------.. _ __... _.. ---_..... __..,_ ,a/' _____ � _. 1 . ., .9 I 1 _ r t T / \ ', , \ r �,f 4. SWEEP AND VACUUM THE FLOOR AFTER REMOVAL.DO NOT USE AN OIL BASED SWEEPING COMPOUND. i t l til>/ I I \. ! , ii; :`. \ L - \ ,, `.,\� {\ \ , - I 4 ALL AREAS ARE TO BE CLEAN. V� 1 I 1 ;S;o £ , ! I i I ( = i I i 1 r -1 i \rf\�\. " \\ T \ \ `\,_ \ �\ \\ \, i\ \ -- C) \ \ - *k :... ..... .... _ ...... __.,_.. .....-... ..... \ \.. - 5. G.C.TO REMOVE ALL EXISTING WALL ARTWORK AND 3D DECOR.PATCH AND REPAIR EXISTING WALL TOuj I I y fi i \ \' .I \ \\ \ \\\\\ `\ \ Y L c \ \ \ at l RECEIVE NEW PAINT FINISH. ( � I_I_I V j i I t I ( 1 + •'\ I \ �`_i�\ \ ' ,.\\�\`'\ `\� j\ , !` II : 'I \ \ ,+'t-;1 V 1 1 I �\\ /i 1 '\ \ \ ` \ ' \\ 11` \ _} , 6. RELOCATE EXISTING SPEAKER FIRE STROBES,EMERGENCY LIGHTS,AND EXIT LIGHTS AS NECESSARY �� w i 1 / { \ \ S S O S G i , T , I 1 I Ql � { Lr }_ r - I ; I ; I ( \`��i J \ \\\ FOR NEW WORK.REFER TO ELECTRICAL DRAWINGS. uj \\ __._ 6 I- -- / \ \ \\ 7. TV'S THAT MEET CURRENT SPEC ARE TO REMAIN.COORDINATE WITH AN VENDOR&PROJECT MANAGER. Hwy I I I / vv\y`^ yA v� v �� \v\ �A \A-..::.(\ },_ V \ I- Q� LL _._._. , /7 - 1.01 1.04 L J 1.01 � A \ V VA `vi \,vV v`\ - \ \� VA" 1 \ V v ,4 Lu I 11 _.. ,..� pr L \ I _ I _ ! 11 (Sv: I i'/ 1. � L. 1 I���__�-__ Ili c� -y t 1 A v�A _ �� ' � , .. V plih. ! f v v ��••v\/� LL Z \ \ 1 , 1 , i r` 1. \ y i . � I \ I of 1 x - \ \ O , cv) w / ® 1 I // ! V `. i I ( I ! b..iw� \I �\ \\' \, ', \\. \ �\ , \\ ''l. \ \I I V, :il .l\': \ ..\� ..,1 ' O yF�}-, . I ( ! �_ i3 h \,, �. ` ,\ \`.'., \ `\`\� ' , , ,` _. ' I "'\ �_ , GENERAL DEMOLITION NOTES O c� N w l " ^ \' - o. Z ; Li`fiffifiviiiiiii i15 11 11 ; - ` \ T ` \ \ '` \- \ ,\ T\. \ \ ^ -_ $ SCALE: NONE _ Of ;.- �''I i I ! --71 Q iI r---j It 3 it ..r, \ '\ \A ..,\,.\•\,\f �I,\ A, ,,\ \ L11 I 1 \\\\11, ^ :+ is N �j� O O -I . . __. ,-.._x__7A___._ -...1.-- -l- {1 _y l \ \\ a \ \ „ ,«..+ k\ m 9 ' 1 it / I / -._-- } ' - - - _. « \ ^ \ t :-. - _ _ 1.XX (PROJECT SCOPE I: 1.L j ! Q ; I 7 I i ,. `fC- y I z7 > .'";•1 I it i 'hi \ -„_:11 ` �-ii Vic.•-7 . \ \ 'x l; - .. _.. {I {x ... ! r 1 1 I �J� I . : I t.s. I . I i I G' + .J> i eL._ I j, '-=;t - 1\ \ l� II`..J +_, \\. -;\ __-`..- � -:.:-1 `\ , h _ O { ��I I I ! `J i ",L; i � \ r. 1_I -!`' =:_. \ \ - EXISTING PENDANT OR TRACK LIGHTING TO BE REMOVED.REFER TO A2.1 AND ELECTRICAL Q O w --.-_.._..._7 ..__...1'7. ... ... �.r F4s..j::. , "hi,., \ "^ ....n ac t __ = _ _ fr 4 ._ .._ \ 1.0, ` ..-..... .............._.. V 1 ,...-.__. ...,..... ,.-...-_ I I ` '{ \ 9 i \`"\\ = SHEETS FOR EXTENTS OF RE-USE OR REPLACEMENT. J VESTIBULE - \ i x Q 1 I i I I ,, E r; 1 to, t � I(Jr � �`.`\!\, � \ , I \ . { .1, ''>,.\`` : ",�!,� ., _ '�.�{,� oo � D y UJ U/�) 101 I , / , j I, I \ . \ \--� I \ 0 r W LOBBY - i. ' . `t \ ti - \ \ \ \\ \ _ 1.oz NOT USED. o O 1 r, 0 /�) I > ( \- \ ' \ 1� _ \ I \ '_ rte! 4 ,� 1 OL \ \' / / i .I 1 II i e^I i ,: ,I ` __ r \\\' 'S _ ti^"kL \ ` -k- x• ;I `._..� \ I \ .. \ r r I • { I " 1 1 I 1.01 {-_ pi!j \F .... i. .\ \ \`, \ '\ N. - . \ ,.� I `'.-\� \I \ 1.03 EXIST.TV TO REMAIN. PLAYNETWORK I OTHERS TO VERIFY. , , , .. I 1 ) r1 .I jj I r� f ```1 .... ,, Y•' ''... , ,'.\ r\\i\ �\ F - a .�,- :z',�1.. �.t\ .� `t l\•. iia. {+ t~ r, u=¢ ,. .,--_"-__.- „-.,_`_ ,ice �� a . L.______ 6 '\ -a'' ;.. \ 1 � 4. , Ii.. _: I `y � �.�..l....,1 '�.. Il] \,\\ t I .,... �to L av I I I \ ! :r \yam, \ „ 1 ' p a �_... \ \ 1.04 EXISTING CEILING FANS TO BE REMOVED. CAP ELECTRICAL. _._ __ w 7'fr , I 1 , ',., _ '\ } \ \, I k' - \q\�,J `\ \.\'�1, ., - #..^ M1 ` 't, r • O - w `i LJ 1 .\ I t _ `t r `\ \: ! 1,11 ` t (;�,,_``\ i, i ` \\ i.. s r'`,y"`�..icl\ £ - i• U p V , - I 11 E ° y ti ..� ( i! - \ \ f= 1.05 EXISTING RECESSED CAN LIGHT FIXTURES TO REMAIN UNLESS NOTED. �D�C m o 1 'll 1.04 1 `L- I(y , 'rI ! t i r .,I\y'+ ', . '` "`,.11` , X 1 r4:. \ \ - , _. a r� a 1 I ,/ 1 ,. > 1 ', \ 11- ;, 1,06 EXISTING HVAC DIFFUSERS TO REMAIN UNLESS NOTED. (U N � _ � 11k ,,,, \ 111 , ",' NOT IN SCOPE OF WORK '\ \ ':-' ® = n \ '�+•.+ i -T'f i ''. i 1.01 1 1 1j 'L1:1� I 3 a t l. : `' '- di , \ \ \, D a rte* y' s , 3 y ` _">, 1.07 EXISTING BACK BAR DOWN LIGHTS TO BE REPLACED. _ a 1 gg it _ `t `i�" :.,,,;i 1.01 I /1 - 1- - : + 4`�:..� k :: , Z: !'Ij sMJ;y:- __ l '\` - t) n - ` -- - - ' Y Y 4*, \ - \,: k _ \' = 1.08 EXISTING LIGHT FIXTURES TO REMAIN AND RE-LAMP ALL EXISTING FIXTURES. o \ 0 a `+ ; IIS I I - i, I'. ''': _\ \ \ \\ f ,\ ,F` \ ,, m °' w c ! I s , / \I \ \ \,'I ` \ I RE-LOCATE EXISTING EMERGENCY LIGHT TO AVOID VERTICAL ART GALLERY. SEE A2.1 FOR - ,. '- m l / \ I 1 T �\! `\ \ \. \ ` 1.09 i((j .1 Vi i= lli .v I i _ i., 1 , _ -} .Y_� /� v _I I '�I t. l `�\ p I, ,S f i\ ."1,-.- Y`, e _ (.I N - r, NEW LOCATION ll a ll J I t ! .. ..._.-. ............ ... ......- i ! ; T .1 N : .-,. ....- ! 7 I i : i ! e i �E(.`.J I i i :� i I Ii Slit ,\ \ 1,., , L, ! ''\ \ ` T. ,�` \ , Tri •, 1 I 1 \ _\\ I : ii. ! I I 1 i/ ' i ;, - 4 1 :t_\L m I1. 1\ \ ,II ...: p . .- \\-- y\ '. ..11= .:?, `, \.:.... .. ....... ...................I. .-....... -,,...-,...., i...-.._.._ _.'_-_____-. , . -._j.-_. ........., r _ .,.,_.. _ ___. __.,. t. _.. _._ -.._.----.._ .._....-...._..- ..- >t n . \, . 1-11 - \ ."Y. _r..{ ,__ is \ ,i� / I , ' I i ' 1 I i_ : ,,0, , 4_- I - I\ ; r.:air,_ 1 \\ . i \ 7 i I I i I i I I I I \/ 1 ( \ , ) \\ I I I ' \i+ - i \ v n �\ `.\• \ .._'\ . \\_ \_ ...-.:....__._ J I __I./_,. �' -. .,._,\.: \� \ \ ._.L.. / I _ .I.... I.........._....--. _ y '_'ray y v I GATHERING DINING - ``'r `` -- ` I ,� ! \, . \ \ .\ \, \ 4 :. ( -.. G ,-� �, / `\ �I 1.01 104 - 1.01 -_) ����1 .7, y _,.11 ,•; '\ ;\\ '", '� 1'\,,;K�y _{. I \ \ \,` , `\ _ 3 " '"ass». ` \ ,.,! h .;' ' I _ ___ _ ___ _____ Ili Rj S1 \.. ' I !-\ i II' : 1.04 J 1 r,, �` ' i '\.IFI \ '- \_\ :I . -..L:" . 1 ;\ \+' ` \\ \ `. ll -. \ r I I I I i ( I ® l I I '`{' f \ ,Y;' tv \.I \\I! I \ .\ \ \`♦.. \•\\ \` \; T.`�I C \ \ \ \ I I �. , , W i t \ \ \ I _..... 1 .........,, .......,.. ..._._ .....- ..,.... ................. ....-.... , ._. __... _...-....1 (.....-...... .-..___-.-. ! _.til . \\ , ,. ., +a:, , , .: ._ ! I I I ,f @ I 1 \ . . 1 ,, �`\\� } \\ \\ ;i:, '\ \\\ \ \\ '`4-: "\., \\.,\\ !! \ .._. _ RBVISIOn$ o \ ', 1.01 i i I . r I ' ( 1 q. I I -c\ - -- ,;:" \ `li ,. _-!i w \,{ :, , ,. �\: ``:..\ 'r_'4 "r,`: \ T I , , +: I J. S; .. .. g« K _... ISSUE FOR SCOPE REVIEW I1. - `, ' i , I n i ( 1 i I I i - , 1 ` I '.:.. \ \ i "> x[ - \i \ ` \ .1',4'7 \ ?S r. 5,,+,: 1- 4 1 � �04/24/14 , s 1 t I I I � 1 if,i� -- _ - - - K y .. ; - , : .... ---' ._ ._ ,. _� _.. .- '+pr , .. 1 \• -- �\ : _� -t• -, -- - 1. g ISSUE FOR IllIN LANDLORD REVIEW I- -__ 05/16/14 - m., 1.01 ; , s ! - N I , J i :- ` +., •,\ , !^s` . \ \ \'XT :;, I I \ \ \I h \�\ ISSUE FOR PERMIT REVIEW -`-�' ;:. __. __ ........... ..... . ........... ' ..;............. ....,...._,,. ....,. -.,... ... .. -.-.-. ., _........ .....L... ,,..,.- ,,y-_. , .., `` '' ... ., t 1.. a 1 I \ \ .1 tiC \ \ \ \ 07/22/14 'a' ,fit ! ' 101 I I 1 a q , :, I \ \ -;:Ir, v _... , \\{\'',\\ \ ♦ \ ," \� , t ///f 1l //11 11 i 1 ' is`'''� _ 1 J I I.. r r IWAI. _ i ' \ / ' - /?' 1 AI I !Tmmm \ .,\ \\ �,.^ _\ \ . \ \ \ \\ , • I \ \ \ \ \ \ \ ---___-...- ----.- --..- ---..___-_ I-__.-..__._._' ...__. - _ 'N \ 111 \ `'\ .d a O � I ! I 1 ( ' i / HALL \ \ \ \ \^\\\\ ``\\ \\ \ '' \ \\{.., \, \\\\,\.,\ ,..,,.,,\\\�� , i j \\ \ \ \ �\ \ \ \ \ \ \ 1 \ \, \ ......... i,' II IT Z A 1• I h�� IC--71 I ,, I II *' I \ \ \ ,.\ \ \ \' ,\ \ ,,\ "\,\ \� \,\\ \ `\ ,\ \ ` ..................__. r .,,..1,,. J ,.. ... e.... 3'..._I, „-,,. /._,..K _ _ ,T\ ,..,.., ;- 106 \ "\ \ \ A \ / 1 I { I \ I { / \ i \\ I \ `\\ \ i I 1.01 _> ® Y Y r _]I I (C �l i 1 t \:� \ \,, \ \ \\ , - . _:_. _........ - - i I ( i Q ® \1 \ \ \ - 10 I , \\ _ , I - --_____� I A A v __- v \� � I \ ` A ll" W , , \\)_li l.oa \ 1 !� \� 1 i MEN \A V `'v�'�,I, Av ! 1 ,Iv, ' v ' \y, - - 26- / _.. ! - � \ Y LL , \ 0 \ \ .- _ I y 1 i ! I , w.i� 1 �0, : { i I ' �I �l .1i .,. \� 11. {.1 1 , II Ta ' \ ` il \\ \\ i \\\ 108 \ I i I I I r , '.SF n - I 1 ! ,z 'r::. -K, 1 \, \ �\ , + -- \\ c. ` \ "' \ \ 1.04 L J l l Ld ! E3 U ;: , , .r _ _ __ P_\_ _ _ __, \ •-. \_ I D n 4 .........L......_._ ...... �,„..�..,..-._. ........-_. 1 i 1 ..-.,.- i BAR / LOUNGE ,. L_. y ` __ 1 _ r k - \ C�, . \, y ; �k� 'o' , I I I �`�` I i I r71-, I I 1 -^'� ' W EN \II ' . \ _ A \ � �.-, �_� .I��, `Vt` V jV �,� ; , ;/� i'' \ '\ C ,.� 1 103 I I 0 -- -_ --- -- \ \T� ?� \\ \ \ ~ _..._ - _- - - - ---- _ .' - - ! - - ` .*x \ 1 \\ \ (� OHNA.CHIPMAN �Cd -_ ,, OM I I 1 _�} 1 {_� - - r a - _ 107 \:_ `\t \ \ \.\\ ` n 3r I I i 1 L ! 1 ..m.. 1 ! j)$f� I 1 Y_/ -'�, _ , j_, V 1 \ I ` ` _ i I 1 I r. __p,. /� \ i :1 '\ \ - _ No.3653 - - -- r ! -<a. a t : :; .,, I...:.. __ -_--1_ �"z-' r n y .--F ,�.. - r . �_. , ` ,1 \ !` ._P\ \ xt !-� E i. -a , I _-„ i ,If. (,,.._^ 4, 1 ! �... _._1 •_I ,. .._._.. -1: T \,J\..-..- 'v-- \,-. y, _ \ \ -" \_ ( -•Y4=a'=X: 'F ' Q I I �,.,.. i. ( \ \ \ \ I 0 DES PLAINES IL • oo ' r,. 1-- - T 1 ..... m \ \ n.,. } - 1 - - - :n I ,, y1,., -_, Ix __ i i - -'I .,.-. \`\' '\ \\ \ ` \ r: -i, d IIOu ,^V,\, ` •` I !' I i + :, ItlmTI �, I I \I 1 � I ki i 1F -- ,07 L--- t,o7 , 07 / Ii l - - - y \� s I \ 1 I I ` s o - - _ ,- -- \ ! I ry0O I1. � \ ` , I .. .......... ..Z�. \ I I i i__� . T Y pp 1 O i i 0` �i _"_' W f �, ®" -' _ "'-_ --' , HEREBY CERTIFY THAT THESE PIANS HAVE BEEN PRE- '- I - ---- �"� I ! PARED UNDER MY SUPERVISION AND THAT TOTHE BEST m I 1 I ! OF MY KNOWLEDGE THE SAME COMPLY WITH ALL RULES, y i I RELATTIING TOSRTIONS AND UCTURESCANES D BUILDINGS.PORTLAND,OREGON 0 ...................................._..-_...,......._..,..........._. I I 11 i I ARCHITECT O i , ,, I I Drawn By Checked By ,` I a i ' m , I Scale Date AS NOTED 05/16/14 Job No. a` a E m` 5 Sheet No. C5 1DEMOLITION REFLECTED CEILING PLAN 4 DEMOLITION KEY NOTES D1 01 9SCALE: 1/4"= 1'-0" SCALE: NONE 111i I I I I i1 6N111'11!IIIII Ii lidi ,[!IJ1HIi'!I 11 II1III1ifiiJ Ili r! '! 11I Ill[ ii I I GENERAL cB Lay. bow . • THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO 1 IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY CENTERLINE uNE CEN FRLINE CENTERLINE HANDICAPPED PERSONS. FIXTURE FIXTURE FIXTURE O� FLUSH 1C-06" 1e' ,g•-fig• ACTIVATOR 12 min 12 min Is- a. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. ON WIDE THE BLUE SHALL BE EQUAL TO COLOR NO 15090 IN FEDERAL STANDARD NO. 595. MIN. sloE RAISED 915 30 r CHARACTERS b. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHERE BRAILLE SYMBOLS ARE _i o C7 ~L EQ EQ. RAILLE �4 O SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE ACTIVATOR Q PICTOGRAM ii ACTIVFLUSHATOR g Z 0.1 INCH ON CENTERS IN EACH CELL WITH 0.2 INCH BETWEEN CELLS. DOTS SHALL ONWIDE (SEC.1117B.5,7) - `�e Do BE RAISED A MINIMUM OF 0.025 INCH ABOVE THE BACKGROUND. SIDE _i : _ i w c ` ov C. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO OF d os. o �, BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND go•MIN.' 4-MAX i 36 min __- v LI \ E Lo 815 alternate 915 V_ < Z d. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER door location �� r����❑ O a r D 24 7 24 LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT 1s• MIN F11 R'MIN. ❑V L�l1Vz _BACKGROUND. 2-522(b-5). I MIN. CLEAR N. CLEAR (a ' w U < U I I n S I �214 -E sProportions Yens Restroom Signage = Q a = <ACCESSIBILITY m EI n SINGLEACCOMMOOATION ACCESSIBLE WATER CLOSET COMPARTMENT Intemational Symbol of Accessibility o °' = 60 min E. TOILET FACILITY IUD LO WITHIN A MULTIPLE-ACCOMMODAMON TOILET FACILfrf ED 2 < C) U U ' 525 2. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE ° I dearA LL L I- 0 THE LEVEL OF THE FLOOR WORKING PLATFORM GROUND SURFACE OR SIDEWALK. \1 floor p ce Q O W tD In ( ) ( ) t 0 3• THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE 60 in (1525 mm�-Dianeter Space T-Shaped Space for 160 Tums �- -k7l (11 LUX) AT THE WALKING SURFACE THAT COMPLIES WITH SECTION 1006.2 4 48 In4 O w < O 4• THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED 34min � Z 3BY THE PREMISES' ELECTRICAL SUPPLY THAT COMPLIES WITH SECTION 1006.3 12 max Display onditions O Flg. 300 5. SEATING AND TOILET FACILITIES FOR THE HANDICAPPED SHALL BE ACCESSIBLE FROM THE Intemationof Symbol of Accessbility Wheelchair Turning Space MAIN LOBBY OR PRIMARY ENTRANCE. 56min w. wall mounted w.c Signage Height MOUNTING LOCATION60 min 60 min 6. THE NUMBER OF WHEELCHAIR SPACES SHALL COMPLY WITH TABLE 116-1 2010 SECTION 56min w. wall mounted w.c. 59m1n w. fir. mounted w.c. 915 42915 1420 42 AND HEIGHT a level11048.3.4. 42 min latch 8 IT min 18 max. min 42 min 18 AS PER 11178.5.77. ACCESSIBLE SEATING AREAS SHALL BE REACHED BY MAIN AISLES LESS THAN 36 INCHES approach only, 59min w. fir. mounted w.c /0-1 455 1085 455 1085 1055 455 1 O 7 Standard Stall end of row) 7'tthn% d°el °"" WIDE. other approaches r eo1 42 46 min . ■ ■ ■ ■ Women s Restroan Signage I loss 8. PROVIDE 80" HEADROOM FROM WALKWAY, CORRIDORS, AISLES, ETC. TO ANY (al i la OVERHANGING OBSTRUCTION. Standadrd Stall �� ICY c o ■ ■ ■ ■ o Fig. A3 (a) 9. PROTRUDING OBJECTS WITH LEADING EDGES BETWEEN 27" & 80" A.F.F SHALL NOT c a E n E Y 00 DO PROTRUDE MOVE THAN 4" INTO WALKS, CORRIDORS, ETC. OBJECT W/ PROTRUDING EDGES E m ■ ■ ■ ■ ■ �' t n Li l 78 min AT OR BELOW 27" A.F.F. MAY PROTRUDE ANY AMOUNT. FREE STANDING OBJECTS � ' flow �] floor M a o "� 1 1985 LU MOUNTED ON POSTS BETWEEN 27" AND 80" A.F.F. MAY PROJECT A MAX. OF 12". flow apace r space W1 - � M N D 10. THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1 1/4" NOT MORE apace i :................................. O O accessible path of travel Q ............................ O THAN 1 1/2" ON CROSS SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN ............•"'•"•••"'•'° 4 C EQUIVALENT G SURFACE AND SHALL HAVE A SMOOTH SURFACE WITH NO SHARP 36min 6 60 mm Intemational IUD Symbol ;'' CORNERS, HANDRAILS SHALL BE 32" TO 34" ABOVE TREAD, EXTENDING A MINIMUM OF v lszs N I,,,,,,,,,,,,; 1480 12" BEYOND TOP NOSING AND 12" PLUS WIDTH OF TREAD BEYOND BOTTOM NOSING AND SHALL BE RETURNED OR TERMINATED IN SAFETY TERMINALS. HANDRAILS PROJECTING I I Fig. 28 "1^ N� 00 En FROM WALL SHALL HAVE A SPACE OF NOT LESS THAN 1 1/2" BETWEEN WALL AND Clear Floor Space at Water Closets o 0 0 0 : : O1 ......•• ........... Z .... ....... HANDRAIL. G @ ; ; p g LU ............: :............: ; I ' i 11. ONE WHEELCHAIR SEATING SPACE IS REQUIRED FOR EACH 20 SEATS, WHICH AT LEAST r7 n 36 min :....... ... .......: :....... ...........: 1- , n ONE WHEELCHAIR SEAT FOR EACH FUNCTIONAL AREA. THE RATIO IS BASED UPON THE � f7 6 •.' '• � v TOTAL NUMBER OF SEATS PROVIDED, THEREFORE IF SOME AREAS ARE NOT ACCESSIBLE, 1 v� 915 54 min oa THE ACCESSIBLE AREAS WILL HAVE TO HAVE ADDITIONAL WHEELCHAIR SEATING TO COVER 36 mi 1370 Unisex Restroom Signage NOTE: Footrest may extend further for tall people Fig. A2 O z THE INACCESSIBLE AREAS. ACCESSIBLE SEATING SHALL BE INTEGRATED WITH GENERAL 12 min 12 min 12 42 min Space Needed for Smooth U-Turn in a wheelchair SEATING TO ALLOW A REASONABLE SELECTION OF SEATING AREA AND TO AVOID HAVING C 30 305 305 " "1085 tonat Fig. 43 I O ONE AREA SPECIFICALLY HIGHLIGHTED AS THE DISABLED AREA. Rear Walla andard Stall 7 -9 paper 36 19 }1936 Fig. A3 = C o R°8tf00fn �° 780 780 915 485 485 915 Dimensions of Adult-Sized Wheelchairs � 12. KNEE CLEARANCE TO COMPLY WITH 11228.3 N _ (d) Fig. 45 Q U 12 max 42 min N7 E International Symbol of Access for Hearing Loss Minimum Clearances for Seating and Tables F SEATING FOR PERSONS IN WHEELCHAIRS IS PROVIDED AT FIXED TABLES OR COUNTERS, A rn 5 305 101 1085 I^ KNEE SPACES AT LEAST 27 INCHES (686 MM) HIGH, 30 INCHES (762 MM) WIDE AND 19 International Symbols 81 min 3�2 min m I Q N INCHES (483 MM) DEEP SHALL BE PROVIDED (SEE FIGURE 118-13). �] (a �b),. Nn a1s I tl" EXCEPTION: KNEE CLEARANCE IS NOT REQUIRED AT CHECKOUT COUNTERS OR SERVICE I "-9" I BackK Wall Sid WWall I FI_ COUNTERS. Fl A n toilet paper 29 UJ 1 _ 12.1 1011.3 TACTILE EXIT SIGNS. TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING w Q� Bora te Closets 81 min 0 $ c E� 815 LOCATIONS: m 12m x J �� ' n LU 1. EACH GRADE-LEVEL EXTERIOR EXIT DOOR THAT IS REQUIRED TO COMPLY WITH SECTION Li-i 1011.1 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD, "EXIT." 36max 17 min = 2. SIGNS AND/OR IDENTIFICATION DEVICES SHALL COMPLY WITH SECTION 11178.5 91s �) 4J0 �� - 9 / Sidel4alls - - a D��ail Hinged �O 17 1 ¢ W Fla. 43 485 DOORS ToAe� Stella """""""""' E floor •••.•..••.. o$ :............................ .... i... r^ 13. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND i space - �� LU W 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES E E v 12280 32 min 32 min : w PAST THE STRIKE EDGE FOR INTERIOR DOORS. E x a els 1s e w 14. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTER BETWEEN 30" AND 44" N N E E V �cc Clear FlbaSr Space E N Z G FINISH FLOOR. 4es N E 9 15. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH 48 48 min o " ; SlidingDoornN/ OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE �0 6 mm toe E 0 Lel_ DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING o••• FlGg 32 knee 8 min tw clearance •• 0 81 UJ 0 n HARDWARE. "Y clearance I m O V N Clear Floor ace Lavatories _ depth I 36min l 10 max 30 _ 16. THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE SERVING OTHER Fl9• 31 g1�� 8 min 6 max 2S5 eo Z MINIMUM OF 48" OF CLEAR SPACE 17 n 205 150 7 THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A Lavatory Clear Flo Parallel h FROM ANY DOOR OPENING INTO SUCH VESTIBULE WHEN THE DOOR IS POSITIONED AT AN i i equipment pe milted In shaded area (a)P (( Maximum k z Q> 0 0 ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION DOORS IN A SERIES SHALL SWING o EQa�-� - L peQQl� �� i i a) or Space el ApprOaC FOldlri )Door Orway Depth > Q d e Fig. 1 i Spout eight and 9 EITHER IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOOR. �iy In 7 4a�7eo 4aa Minimum Clear Width Knee Clearance O Fig. 24 17. THE EXIT DOOR SHALL BE 36" WIDE OPENING IN DIRECTION OF TRAVEL 70 NO LESS THAN - sz8 l for Single Wheelchair Clear Doorway Width and Depth O Z (n 32" CLEAR. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR 1 j i w EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. SUCH PULL OR PUSH EFFORT L IT 30 TI C) 0 W BEING APPLIED AT RIGHT ANGLES TO HINGED DOOR. WHEN FIRE DOORS ARE REQUIRED, 48 min CD J (� THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15 V I F-- LBS. THE FLOOR ON EACH SIDE OF DOOR SHALL BE LEVEL WITH A MAXIMUM HEIGHT ll 1220 1117-19 48min 48o in O - DIFFERENTIAL OF 1/2" AND SHALL HAVE A THRESHOLD WITH A SLOPE NO GREATER THAN rr�,,)) Forward(b/(pproach 430 10 max 1z0 1:2 High ForwaAeach Limit zu Teo O O Q LI 18. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY THE WHEEL CHAIR X c FOOT REST WITHOUT CREATING A TRIP OR HAZARDOUS CONDITION WHERE NARROW FRAME G� 1 1 2 3 4 E DOORS ARE USED A 10" SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE o n Q m DOOR WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEEL CHAIR FOOTREST Takes tranefx posttlon, swinge Ramovee armrest, tranefaro Moves wheelchair out of the Positions on toilet, releases ? ' footrest out of the way, eats way, changes position (some brake. o : _ brakes. people fold chair or Rival It 'O WITHOUT CREATING A TRIP OR HAZARDOUS CONDITION. `r yy�� tlyow Iv V! C uo 'O �� 90' to the toilet). � 9 ' *� ? i i r � 24 max of - •o, .........................: (a) i............................................ 810 PUBLIC RESTROOMS dX Diagonal Approach 48 Fig. 26 (GENERAL) } (b) 19. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIREDL 2zo Two Hinged Doors in Series - Clear Floor Space TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH 60min Parallehip u J VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NOT MORE THAN roach lszs ` " c 44" ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO 48 I I ° GREATER THAN 5 POUNDS. 12zo I 30 min High and Low (b) Side Reach Limits Full Side _ Push Side eQ= N _ n v I Fig. 2 20. WHERE URINALS ARE PROVIDED AT LEAST ONE SHALL HAVE A CLEAR SPACE, 30" WIDE X Z Minimum Clear Width c r , 48" LONG IN FRONT OF THE URINAL. 30 0 U Q r o 48 far Two Wheelchairs ; 21. A PROJECTION OF A LAVATORY BOWL INTO THE 8" CLEAR SPACE, THEREBY REDUCING THE lzzo 78o n m iy CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN 27" AT 8" BACK FROM THE 18 min, 24 referred APRON, MEETS THE REQUIREMENT FOR PROVIDING KNEE CLEARANCE. A MAXIMUM HEIGHT OTE: X,shall be Y,5 6 m ),Z all be x. en 20 in 510 m),,then y shall be 48 in (1220 mm) maximum. 1 2 3 5 N [[ 5 Q �t I c OF 34" 70 THE TOP OF THE LAVATORY IS RECOMMENDED. When x 6 20 to 25 InJ1U t0 63�mm),then y shall De 44 �I (112U mm maximum X E o Takes transfer position, removes Transfers. Positions on toilet. 24 22. TOILET ROOMS SHALL HAVE A CLEAR SPACE FROM THE FLOOR TO 27" ABOVE THE FLOOR artnreet. Beta brakes. _ 5 door has both a Maximum Forward Re�b over an Obstruction b """.."..•••••'..................••"••"••"•••'.. leo oro OF A MINIMUM 60 DIAMETER OR 60"x 59" for FLOOR-MOUNTED W.C. WHEN DOOR SWINGS Fig. 5 Side Approach _T IN. AND 56"x60" WALL-MOUNTED W.C. WHEN DOOR BHANGS IN. ........................... = dos and lafch. ) < Forward Reach / NO an12 in (30 mm if Fig. A6 's ( Front h s' - S h side d 23. MIRRORS SHALL BE MOUNTED NO HIGHER THAN 40" ABOVE FINISH FLOOR TO REFLECTIVE clear width an amount Wheelchair Transfer ,� ` ` ' i ... . ....... .. Fr a-5c) in Pull Side rOn OCC Swinging g OOrS 54 m Pus e i ... ......... ... A ro a) in in D SURFACE. N dd .......................................... 1370 E o OTEx <24 in (610 mm). Foune{ain o�nCob�er 24. ON TOILET ROOM ACCESSORIES, THE OPERATING PARTS OF DISPOSAL AND DISPENSING 4 max """""""' Lo, I SHALL BE 40" A.F.F. MAX. Lobby 10a reater than 12 >< �- _ 0 ev 25. ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL COMPLY WITH THE 11158.3.1.4: 305Frenter than 12 '• ? tzzo Dantean depth COPE REVIEW 308 i 48 3�;a min E i .'" a. THE COMPARTMENT SHALL BE A MINIMUM OF 60 INCHES (1524 MM) WIDE. not to exceed n } Revisions E E............................?..............................: r d to } 04/24/14 S b. IF THE COMPARTMENT HAS AN END-OPENING DOOR (FACING THE WATER CLOSET), m nim m if.y LANDLORD REVIEW EITHER IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES (1524 MM) WIDE AND N x NOTE: 915 mi 60 In ISSUE FOR 48 INCHES (1219 MM) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF �� >< 66 min o$ - - _ � I S/16/14 s a, ,B7s ( 1525 mm); x = 42 a1�065 mm) minimum if THE WATER CLOSET. THE DOOR SHALL BE LOCATED IN FRONT OF THE CLEAR FLOOR of o E ,a r7 n E o Maximum Side ReactlC)over ObS1NCtI0n m (1370 mm). y ISSUE FOR PERMIT REVIEW SPACE AND DIAGONAL TO THE WATER CLOSET, WITH A MAXIMUM STILE WIDTH OF 4 oro a .o N n 1 „••,,,, both a latch and Inmum if door has 07/22/14 t Fig. 6 48 in (d1 ser. mm a t o � r INCHES (102 MM). I •...•..•••.•1 .•. i ) X NOTE: m w t ; i N m Plan Elawtion / N TE:x < 15 la 3t}b mm. Side Reach fb c. THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS ' Fig. 8 (C) Free-Standing Overhanging Objects Forward or(Rear Access Hinge Ida pp aches - Swinging oors AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING I i 1 In 5 A r0D Q WIDTH OF 32 INCHES (813 MM) WHEN LOCATED AT THE END AND 34 INCHES (864 I (d) X X r MM) WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 i Clear Floor Space in Alcoves 4 min Push aide Q Y DEGREES FROM ITS CLOSED POSITION. protect shaded ((dd Pull Side 510 1 1 Bult�ln area from Fountain or Cooler ......••..••..•..... mo oiLErs1 cross-traffic 0 - 26. HANDICAPPED WATER CLOSETS L Fl 8 (a) a. HANDICAPPED WATER CLOSET SHALL BE INSTALLED MIN. 18" FROM THE Walking Parallel to Wall E _ `: r: SIDE WALL TO THE C OF THE WATER CLOSET. Fig. 27 Drinking Fountains and Water Coolers o } • } s 'o b. HANDICAPPED WATER CLOSET SEAT TOP SHALL BE 17"-19" A.F.F. a� C. PROVIDE 28" CLEAR SPACE BETWEEN W.C. & FIXTURE OR 32" CLEAR SPACE TO N m i 7 - Z S - ` WALL X E o oETE �7 NOIE y = 54 in (1370 mm minimum if doe has D Z d. W.C. COMPARTMENT DOOR TO PROVIDE 32" CLEAR WIDTH FOR END ENTRY OR 34" closer CLEAR WIDTH FOR SIDE ENTRY. DOOR TO SWING OUT & BE SELF CLOSING. cane hits poet or pytan - e. FLUSH VALVE SHALL BE LOCATED ON THE WIDE SPACE SIDE OF W.C. & THE before person hits ob)ect POUNDS. Fig. 8 c-1 Overhead Hazards Fi a1 i x 'E NOTEy = 48 in (1220 mm minimum if doe has �,�ti FORCE TO ACTIVATE SHALL NOT EXCEED 5 P ( ) d0aef g r r Minimum Passage W'9idth for One Wheelchair ......-` an w i CHIP A z7. GRAB BARS: _ and One Ambulatory Person 30 6 E 21 max. Latch Side Approanc��s - Swinging Doors t�~ JONNA M N a. ONE AT SIDE, 42" LONG EXTENDING 24" IN FRONT OF WATER CLOSET MOUNTED / a comply F' 25 � � s3s NOTE: All doors in alcoves shell can I with the clearances for front approaches. No.3653 AT 33" A.F.F. / >z x i predominant direction NOTE:x >24�n 610 m}rr�,,t g an dd-tifteal i 1s DES PLAINES,IL / E of traffic maneuvering lea once a m 0 mm� a be O / M Ig t D s b. ONE AT REAR, 38" LONG, MOUNTED AT 33" A.F.F. / E ••••••••••••••••• provided as own. helves Maneuvering Clearances a Doors fro C. BARS SHALL BE 1-1/4" TO 1-1/2" DIA. WITH 1-1/2" CLEAR TO WALL Ne '.. •• d. BAR FASTENERS AND MOUNTING SUPPORT SHALL BE ABLE TO WITHSTAND 250/ ........ POINT LOAD IN BENDING, SHEAR, AND TORSION. K� 1 2 max ° i / 13 i i a in min ;... i (URINALS) acne range Fig. 54 m 28. HANDICAPPED URINALS Laawtlon 12 max cone ange -CUP ` J 3os Fig. 8 (b) Tableware Areas d V a. HANDICAPPED URINAL SHALL PROJECT A MIN. OF 14" FROM THE WALL, Walking Perpendicular to a Wall AND THE UP SHALL BE AT A MAXIMUM OF 17" A.F.F. Fig. 8 (d) E PRE- lo. THE FORCE TO ACTIVATE FLUSH VALVE SHALL NOT EXCEED 5#. Objects Mounted on pPosts or Pylons a a X - - 'a 1 36 ` HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- Fig• 8 - ? 9 15 m d Slide 5 eJ PARED UNDER MY SUPERVISION AND THAT TO THE BEST ° LAVATORIES FI B Protruding Objects Fl 8 Front Appro Iden Doors i e cfhl - Sliding Doors OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, 1 9• Fl9. B�f 9• (9) ) e A r 11 in I} 7 E 29. LAVATORIES Protruding Objects (Continued) Carpet PIle Thickness Gratings I """"""""""" and 010 g oorJ an��old g Doors ELATING TO STRUCTURES AND BUILDINGS.( g id o a. FAUCETS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT I 4 I I t n D in D REGuunoNSANDoeDINANCFsoFP OREGON long dimension rf�(3 �J�ss { R REQUIRE GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE perpendicular t0 NO.�,. (I 8 I E I NOTE All doors bI alcoves shell comply with the clearances for front approaches. _ REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED FIVE LBS. FAUCET 12 maX rOUte of travel X15 0 m�In), tb�J an additionpl HANDLES SHALL BE A LEVER TYPE. 305 o maneuvering cieara ce of l2 n 1305 mm Shall bC b. PROVIDE CLEAR SPACE BENEATH LAV. (KNEE SPACE) 29" HIGH, 30" `° ARCHITECT �` 66 min provided as shown. r WIDE, 17" DEEP FROM FRONT OF LAVATORY. , 24 min C. LAVATORIES ADJACENT TO WALL SHALL BE CENTERED 18" MIN FROM cane range 1875 E 21 ma e10 Drawn By Checked By WALL, WITH RIM OR COUNTJ TER SURFACE 34" A.F.F. MAX. E �j r d. HOT WATER AND DRAIN PIPES UNDER LAV. SHALL BE INSULATED. (b) Additional Maneuverings earances for Alcoves M s3s E AS NOTED ' ' Side Access V Scale Date ' 1 � /, 05/16/14 y ' I N (b) Closets thio overhang can be Job NO. greater than tz (3os) 9 Fig. 46 Fig. 4 Ei9• ,53 Fig. 38 (f) o because no one can Fig. A4 ) Minimum Clear Floor Space for Wheelchairs Food Service Lines Latch Side Approach - Sliding Doors and Folding Doors °ppTOOCh �° ab)°°t Cane Technique Gratin g Orientation Space Requirements for Wheelchair p Storage Shelves and Closets pp g 9 nom tai. dVection Plan g Seating Spaces in Series a , „ Maneuvering Clearances at Doors (Continued)25 Sheet No. 9 A001 CODE DESCRIPTION M-$ ACRYLIC DIVIDER&POSTS(48") SYMBOL DESCRIPTION M-1 HOST PODIUM M-9A BACK BAR GLASS SHELVING _ ITEMS TO REMAIN M-2 HOST CABINET M 96 BACK BAR ACRYLIC PANELS NEW WORK ITEMS FULL HEIGHT LOUVERS-SEE 24"x24"CARPET TILE: PATTERN T.B.D. Nv\ M 3 DETAIL 41 A5.0. M-10 BEER I LIQUOR DISPLAY PLAN NORTH MASLANDCONTRACT:SPEC.T,B.D. �� S O WALL HEIGHT LOUVERS-SEE O CP-1 SOURCE:JOHN LONG,630-745-0468 JOHN.LONG(oMASLANDCONTRACT.COM M-4 M-11 RUBBER TRANSITION STRIP-BURKE FLOORING-MERCER#910-2112"BLACK SHEET A5.0. STAINLESS STEEL GLASS RACK 0 WOOD FRAMED ACRYLIC M-5 M-12 WAINSCOT TRIM. (ALL) 12"x12"PORCELAIN TILE(UNGLAZED):DAL-TILE DIVIDERS-SEE SHEET A5.0 ART DIVIDER-SEE DETAIL PT-1 CONTINENTAL SLATE SERIES-INDIAN RED#CS51 M-6 M-13 5l A5.0. COLUMN COVER w/MAPEI#37 TERRA COTTA GROUT, 114"JOINTS M-7 ACRYLIC DIVIDER&POSTS(24") M-14 TOP CAP&TRIM(ONLY) _> 4"x12"PORCELAIN TILE BULLNOSE TRIM#S44C9(UNGLAZED): PT-2 DAL-TILE CONTINENTAL SLATE SERIES-INDIAN RED#CS51 ED wl MAPEI#37 TERRA COTTA GROUT,114"JOINTS MILLWORK PACKAGE B.O . o T ... u . ...... e o' u�. o' 4rr•�.h . p.. •:- , .. . �_ ;.. .._. , _. .•.. . 5 ( ) \ \ \ `, \ NOTE: { \\' REFER TO SUPPLEMENTAL DOCUMENTS FOR INSTALLATION GUIDELINES AND SPECIFICATIONS. SCALE: NONE i I ,�_�, \ PLAN LEGEND ° %,-'f' \ p'�'-f= { cab-9' I .p '4-I �, \\ \ _. \ \\ \ \ SCALE: NONE A I I{II -. F �j '{° -rti ' -1 I I -. ' Ili <I i 1 I ii ! v \\v A\,.. `.VA, AV , \ I I I I i I I I 1 1 M-7 FURNISHING SCHEDULE I I� I I ,. .. \��� \� i I ( ,,,„„„„ �; 1 h-- - =1 I I I �=I I I I r I \ \\ I . ( I I I ' _ I I I I I _ i t rt, , M_7j_._.: M-7 I ! I i I I I I I I I i ! V A V Av`' ` \ CODE DESCRIPTION CODE DESCRIPTION F-4TC ; __I F-4TC L _ ..i � ( F-4T 1 I j I F-4TP (- F-4TP { f� ( PT-2 �„ ' F-4TP (- _j { F-44P L { F-aTC ` ",\\ \ V `v,v \, VA,v O 6r( P �\ \\`\\ \ `\ ENTRY FURNISHINGS 48SB 48DB 48SB 48SB 48DB 48DB 48SB `- 2.05 48SB 48DB 48DB 48SB -- \ \ \ ` -y m PT-2 PT-2 TyP PT 2 6TCD \ \`\ \ \\ F-50 EXTERIOR TRASH RECEPTACLE 1 O O \\\ \\ \ \ `\ \\ F-51 EXTERIOR ASH RECEPTACLE - \ \ J LU W 2.04 0` A - -A4.0 <0 r x ,�i 2.04 \ \ \ \ \ TYP. TYP. -� d TYP. v vvv� \y CH BARSTOOLS TAB SES �bQ�j c i A\\\ \A \ VT Q - -- -- --- -- - - -- -- -- ---- - -- --- -- - - -- - -- --- ---- -- -- ----- --- -- -- 7 \ \\ \ \ ''•\ \\`\ \ F-4B AI S H�WOOD DINING CHAIR-BAR FINISH F•2TPLE BA2TOP PEDESTAL BASEZD F-4/6TF`. F-4S F-4S F-4S F-4S F4S F-4S F-4S F-4S F-4S ACz \ \ \ \ \ I Q T T A4.0 F-4R WOOD DINING CHAIR-RED FINISH F-3SP 3 SEASON PATIO TABLE BASE \, FdS WOOD DINING CHAIR-STANDARD FINISH F-4TEL DOG BONE EXTENSION LEAF UJI V) T - F-4/6TF --- - , \ F-2/4TF f-4TPHC F-2/4TF- f-4TPHC F-2/47F- F-4TPHC " a').-:_= \ \, \ •.,' \ \ ' =: m b� v i_-__ F-4/6TF F-4/6TE `- z-t \ \ \ \ GATHERING CHAIR-FULLY ' F-5 F-4TP 4 TOP PEDESTAL BASE W UPHOLSTERED-RED 7 Z 1.05 F-4/6TF F-6 METAL BARSTOOLS F-60TP 60"TOP PEDESTAL BASE p O \T F-4TC ` v y F_7 METAL STACKABLE CHAIRS F-66TP 66"TOP PEDESTAL BASE L - -- -- / - R -- - --- ' ----- ------ - _ .-_- ..-._-. -.- .-- -- _ ._.. ----- -- PT-2 --- - $ -- --- -- --- - -- F=8 RESERVED FOR FUTURE F-72TP 72"TOP PEDESTAL BASE / - _ 2.04 . .. �. ` A4.0 h, \ \ \\ \ FF9 RESERVED URFOR E FPTUFETOOL 22 F-82TP 82"TOP PEDESTAL BASE F-4/bTF ? TYP. m - - - \ \ 30SB 2TC 30D _,... _. 2TC 30DB 2TC 3058 , J F-CB CES GR 0 S - - -20 PS PATIO CHAIR-3 SEASON O m f-2/4TF- F-4TPHC F-2/4TF F-4TPHC F-2/4TF F-4TPHC ,;M�""""`- `" � b� v � •,j F-21 PATIO BAR STOOL-3 SEASON r _ PT-2 N _-•. _ , \ ` W \� s i r•,, _. _ exumvwxnna .; ( F-22 PATIO BANQUETTE 3SEASON _ F-4/6TF F-4S F-4S F-45 F-4S F-4S F-45 F-4S F-4S F-4S - 2.040 - k - d \ F-23 RESERVED FOR FUTURE I N -- F^4TP b b� TYP. FAMILY DINING \ F-24 RESERVED FOR FUTURE - - - -. Ent F-25 PATIO UMBRELLA 3 SEASON W/ -.{.� a0 F-4/6TF. OJr \\ \\ .,\ .\\ +, w \ . \\ ` \\.� ` \\ ` ` \ \ ` \ . -'; ' y.,or,: „' c) AR yR PT 2 1 1 \\ '`,., \ \\ \ \ \ \ `. ` ' \\\\ \ \I \, \\ F-26 RESERVED FOR FUTURE W O \ \ • \�: \ \ \ \ \ \ \ \� , W - - A4.0 - M-7 M-7 \\\ ```\\\ ,` \\\\ \ \•\ \ .,\ \ ` \ -\.\`, \ ! r._ } \ \ w F-4/6TF TYP. \, F-30 PATIO CHAIR 4 SEASON � \\' C \ \ \ F-31 RESERVED FOR FUTURE W F-6TC m M-7 of \\, \ \ > ('\\ \\\ \ ,, \\ RESERVED FOR FUTURE Q� 00 \ ` \\ I - - - �.v \ TABLES BOOTHS U J -- . F-4TC. - M-6 I\ A ` \ \ A �Av `v A ` \ \\ v ` F-2PAB 2 TOP PATIO TABLE-BAR HEIGHT F-CB CURVED BANQUETTE Z � ) - PT 2 Z O - A \ �\` \ V A• V v \v• v ,� V ' ! .' F-2PAD 2 TOP PATIO TABLE-DINING HEIGHT F-STB STRAIGHT BANQUETTE Q V - 2.04 F GBPS M 3 2.04 5 03 -� o" \. \ . \ `\. . I \ \, N Cr J \�\ \ \ • \ \ \ i , \ n F-2TBT 2 TOP BAR TABLE W/PURSE HOOK F-24TBR BAR BANQUETTE WI RISER TYP. Iw -f-,-_> • 'c-�I \i ,_\. \ \ >a \A\\ (D` \ \ '\ \ \ \ \ I i \ , 1 ' TMP' A4.0 _- \ \\ \I \* \ \ , \ ' `.\ \ \ ;r \ \ M Y_ ,': F-2TC 2 TOP CANTILEVER TABLE F-SWB 20"DEEP SETTEE WAIT BENCH N \, \ \ r \ \ \` i �) \ \\ \ \\ \\ \ \ \ \ \ T\ F-2TCD 2 TOP CORE DRILLED TABLE F 6TCB 6 TOP CORNER BOOTH = M3 Iw L-- -J M-7 Jam) \ I ... ..,T \ ,\ �.I \, \ `, , \\•\ �k\ ' \ 1 _ F.� \ \ \ ° y. �L ` 6 TOP CORNER BOOTH WI N Z L L -- - i I I i ��' \ � � \ .,\ �\ �" ,\ \ \ \ ` \ \ G w`- F-2TPB 2 TOP BANQUETTE TABLE F-6TCB1 Z - --- F-2TC f r \\ ` ` \ \ \ Al ACHED48"SINGLE - Q O O 1.02 F-4TC _\ \\ - a \ `. \\ \ ` \ m > Z i M-6 \ \ ;' `> \ \ \ \ `' \\, \ \`'- U 6 TOP CORNER BOOTH W/2 > \ ! F-2TPG 2 TOP GATHERING TABLE F-6TCB2 LL \ ` r• \\ T i , ' ATTACHED 48"SINGLE UJ i \ \ \ \ `} V \\ \ ., i F•214TF 2/4 FLIP TOP TABLE F-6TU8 6 TOFU'BOOTH �/ W VESTIBULE LOBBY / = m i 7L' ,. \ .: \ \ \ .., \ cn Q Z z.a1 1 3 \ \\`', \ \ yl Iw: \` \\ \�4\\ \� \ \\ VM \� \\ \ RESERVED FOR FUTURE USE F-30SB 30"SINGLE BOOTH Q Q - ` 1 1 A4.0 A4.0 102 M-2 \ \ `, \- \ `,i \�\ \ ti+ 3 SEASON PATIO TABLEW � 12 02 M 1 ,i \ k ` \ \ \ \ \ \ t , F-3SPTH 3 SEASON PATIO TABLE-ADA F-60SB 60"SINGLE BOOTH W LL �_/� ( % F-4PAD 4 TOP PATIO TABLE-BAR HEIGHT F-66SB 66"SINGLE BOOTH -. - PT-2 \ ,\�• \ \ \ \ \ \ `` \ ` 4 4 TOP PATIO TABLE-ADA F-72SB 72"SINGLE BOOTH =M6 \ a HC _ 1.03 2.04 \ , \\ \ \\ `1, } \, \ \\ t \ 1 \ ` ` 4 TOP CANTILEVER TABLE F-82SB 82"SINGLE BOOTH 1.04 _ \ \ t ., { \ v TYP. TYP. \ \. \ •`. \ # \\, ,, \ I F-GBPS __ _-_.-_._ 4 \ \�" `� '-�` '` �. �'a' ' F 4TCD 4 TOP CORE DRILLED TABLE F-30DB 30"DOUBLE BOOTH _.__... .. \9 4 _ C , �� 1 I 1.03 A4.0 \ \ \\ ` F-4THCW 4 TOP TABLE-ADA(BUTCHER BLOCK) F-48DB 48"DOUBLE BOOTH TYP. CI" .� • NOT IN SCOPE OF WORK \ zn a F-4TPF 4 TOP FLIP TOP TABLE F-60DB 60"DOUBLE BOOTH (D"''; , x* _ _, F GBPS 2 PT-2 M-3 M 3 o '"' �l ` 4 4 \ \ t to A4 0 I / I I k '. F-0TPH 4 TOP TABLE-ADA(OA F-66DB 66"DOUBLE BOOTH o C K VENEER INLAY) CP 1 / / L -- -J J m �\ d 2.04 n ti o G F-4TSQ 4 TOP SQUARE TABLE F-72DB 72"DOUBLE BOOTH U ° o ��... v TYP. F-4/6TF 4/6 FLIP TOP TABLE F-82DB 82"DOUBLE BOOTH v m F GBPS A A A of 1.09 F-aTC - ti ` , \ T w :I RESERVED FOR FUTURE USE F-48/30DB 48130 DOUBLE BOOTH , \\ ` . "� �, `�. ;AAV vv A F-6TCD 6 TOP CORE DRILLED TABLE F-48I30DBR 48130 DOUBLE BOOTH U c a \ \ a -- - M-7 m ,;� v A ...,i ":\• '�� A` REVERSE o »a •.'1 V ,,. f ,.4 ,(•..�,1 I ���\� `. AV V -\ASI \V '..,A,\ " ,. N ao o �; - a � a F 6TUT 6 TOFU'TABLE F-82SDB 82"SPECIAL DOUBLE BOOTH .. . '•V � I,• :__ . :.--C_A ., ,I ,. , .. t1.� r�e+x�.t.� V \, y :V '., i\ } `5.�\ti V .. ,` �\1"�h.. 1 � � � � � � � � � ,. � �- ''m , k y�= ?- ,;v �`V •n A�, i-, : , '\ I ' 'v ' V � , ,v : k :� �. A`,�V�`� � �v,,.!v_, _,A �"c F-PUM 3 SEASON PATIO UMBRELLA F-5 _ f f M-7 A i, ��\\��.`I i� ;. .., v� �-. .,, �� �, , A� �i V s y ,v v , AI, ,�• I r r r r r r r y v FaTC � .� FURNISHING SCHEDULE B.O . F 6TCD F 2TPG F 2TPG F 2TPG F 2TPG F 2TPG'- F-2TC ` _ �., -,_ \` �` ) v v ` v a I � r \ \ r r rrr rr� �`� 1 � �I \ 3 _ ', „ I 'A Y, it ' '. A .. I ( '� \ 5 \ � h i i � \. ` ��•, �/ f \ ! \ t v y A A '. V,A I V V; \ 1. ) v SCALE: NONE 4EF-5 /� - - F- IAF5 F5 F5 5 t d \ 12 \ ", 1.XX (PROJECT SCOPE): r r A4.0 r -. , 1 vv y`,v vy !I ..y v {` v v } y ` , v ;; ,,� f \ M-7 M-7 VA V`• V rlk V 'r C V I },. \y A v , Revisions 4 B� 0� 51G 3 S 48 4 � °� 0 A v V I T, F 4 xA V AV , `, r\ 1.01 NOT USED. ISSUE FOR SCOPE REVIEW "l F-4TC PT-2 \ \ \ \ T - __'\ ` . .' ` \, , '} \ . 'F ,1. i,`, ,�, I'41{'� , r3,r 1 ,' !'x4rtl I, A"}J4.•\ J 'I \ r r f O \ T T}a \I pp 04/24/14 � Jy ...Sa ,. ; �. ! L a; y, `1 HOST COUNTER(B.O.) EXISTING HELIUM NOZZLE,ELEC.,PHONE&DATA TO BE RELOCATED i \ \ \.....,t / > \ " .,` : " L,.' ' ; , . ..:,.:` , s 1.02 ISSUE FOR LANDLORD REVIEW 2.05 \ \ \ \ .. \ \ z.;. . ,1{ \ TO WITHIN VERTICAL LOUVER POST. HELIUM LINE TO BE RE-USED FOR COMPRESSED AIR. r� \ T I I I I J L I I I I -1 f \w> I ` < u os/tb/1a TYP. + ° ISSUE FOR PERMIT REVIEW f f I I I I I I 11 I I I 1 1 1.06 „ ' \ \ \ LOUVER DIVIDER PANELS TO BE INSTALLED TIGHT TO EXISTING WALL. J L REFER TO INTERIOR ELEVATIONS SHEET A4.0 AND DETAIL 4/A5,0. 07/22/14 EXISTING BENCH TO BE MOVED IN FRONT OF LOUVERS, x \ 0 7 M-5 M5 M5 M5 M5 3-8 �; I, A , • 1 . � VA \ \\\ \ v VA VA 31 F-XB HALL VERTICAL GALLERY DROP.REFER TO INTERIOR ELEVATIONS A4.0 AND DETAIL 61 A5.0. a lti-ai la' 1.06 _\\. \ \ `., ,\ \\ \ \ \ , . \.•\\ z - __` 1.13 _ \ \ \ - \ \ \ ` \ \ F_6 1 13 I ti 8 A4 1 1 1 O6 \ y A� A y, v� V v\'y' ,. V v\ \�, `\ `•, `\ \. 1 O6 NEW LOCATION OF EXISTING HALF-HEIGHT WALL. PATCH&REFINISH ALL DAMAGED F-2TBT F 2TBT F-2TBT F-2TBT F-2TBT F 2TBT F-2TBT \, \ 1 SURFACES. � .. O \ NEW TILE TO FILL SPACE WHERE HALF-HEIGHT WALL WAS SHIFTED. TILE TO MATCH PT-1 I ' F 2TBT i I =i; F6 Fb ' F6 F-6 F6 F6 F6 € \ in, EXISTING. SEE TILE SPEC.ON PLAN LEGEND. EXTENTS OF NEW CARPET. SEE PLAN LEGEND FOR CARPET&TRANSITION SPECIFICATION. {!I F-6 \ \• ` \ \`\` ' \ \ 0 7 Y ' F 6 F-4B F-4B 22 13 { i \ ` `� t` L - \\\` \ EXISTING TILE TO REMAIN.APPLY FLOOR LEVELING COMPOUND OVER TILE FOR A4.0 - ., , �` ,AA� `'�.\. AAv .v v ,.. ., \a, A � f i A, A l = .'! 1.09 BAR LOUNGE PT-2 \ \ Vy-' � '_ PREPARATION OF CARPET INSTALLATION. Q�� !IjII A4.1 t MEN ...,i"',":'., `.-•. ',I '` _v..\V ,,..\•.\'\` Vv I\,A..v` \ A� '(._•y l'` A, I . 'AI 1 D� r v F 6 F-2TBT- 4THC W 1 O3 2.04 �, WOMEN "� - '' v. `, A 'A v`• "' "- ""' �v A ` -. 2.07 1.10 REPLACE WOOD BASEBOARDS THROUGHOUT FRONT OF HOUSE WITH NEW TILE BASE SPEC. r i -- F-6 F 6 F-66 F-6 F_6 _ F 6 __- TYP. 1 U8V\ ti�j� II� INSTALL NEW GLASS RACKS IN SAME POSITION AS EXISTING INVERTED MOUNTING) C7 JOHNA.CHIPMAN Tf} F-2TBT._ I vv\ ( F 6 F-aB F-aB - s O _..: s 171 No.3653 zr €s r 2, a--:: :r; `\ \\ , INSTALL NEW FLOOR TILE AND BASE AT LOCATION OF PARTIAL DEMO'D HALF HEIGHT WALL. W :u.. ::.I -___- `I I ..... .-, ,�,.,.-,...�: ,, ... '-.. \�:,. \(, +z. .. \\ ....�._ \ i I .. \ ',. . \ , \ ,, \ . ':r 1.12 F-b 2.04 I :.' _. ,,. LJL, .,, e::,:. { ,, ',. ,,. � i .ti �\ r-: u, TILE TO MATCH EXISTING. 0 DES PLAINES,IL • F " F - \ \ \ _ }. . .a<� i '... 't-'..I. \ '• \ mow..: ;:x l w :.: TYP. ! INSTALL NEW FLOOR TILE AND BASE AT PREVIOUS LOCATION OF HALF-HEIGHT WALL. =• ,(�� j ,._t-_.ice I --� _ 7 - n I. -61 ` ,--. _ , � r \ r -6 F-4B F-4B 1' ; \ '\ \ \ _, \ \ \ \w a y EXTEND TILE UNDER NEW BANQUETTE. TILE TO MATCH EXISTING. \ \\ \� \ � f-21A1✓ 4THCW t---- .... 1: J F-2iBT _ \\ (DEFERRED MAINTENANCE): F-4B F-4B_ --- :I __ \ 9 \ : :I I- 2.XX M-11 � M-11 � r ��--•'�I I � � � \ 4 - - ' ;,-x.,-, •' \ 2.01 PRESSURE WASH CONCRETE IN FRONT OFENTRY DOOR. ti/a � ,, I HEREBY CERTIFY THAT THESE PIANS HAVE BEEN PRE- I - / _ _ _ 1 NEW 18"(CENTER TO CENTER)STAINLESS STEEL DOOR PULLS WI BACK PLATE TO REPLACE n - IN N, 4 "' ' PARED UNDER MY SUPERVISION AND THAT TO THE BEST ` 2.02 EXISTING RR DOOR PULLS. RREGULATIONS ANO OBmNANCES OPORTLLAND,OREGON (PART NO.BF159x630-70G MFG.BY ROCKWOOD) PROVIDED&INSTALLED BY G.C. RELATING TO STRUCTURES AND BUILDINGS. Ci 2.03 NOT USED 2.04 REPLACE ALL WOOD BASEBOARDS WITH TILE BASE. SEE MATERIAL LEGEND FOR SPEC. ARCHITECT 2.05 REPLACE WAINSCOT WHERE NOTED. COORDINATE LOCATIONS WITH FACILITIES MANAGER. Drawn By Checked By a 2.06 REPLACE TOP 50% OF WOOD CAPS. COORDINATE LOCATIONS WITH FACILITIES MANAGER. Scale Date AS NOTED 05/16/14 2.07 INSTALL NEW MMA FLOORING IN RECEIVING DOCK. Job No. a m` Sheet No. FURNISHING PLAN 4 FURNISHING KEY NOTES A2 . 0 9 SCALE: 1/4"= 1'-0" SCALE: NONE I SYMBOL DESCRIPTION SYMBOL DESCRIPTION 4 TRACK HEAD-DOWN (CENTERED ON TABLES) ITEMS TO REMAIN ■ Ili TRACK HEAD-UP 45° (UNDERSIDE OF GALLERY @ 24"o.c.STAGGERED) NEW WORK ITEMS �� Q TRACK HEAD-LOBBY ART WALL, LOUVERS,ART DIVIDERS 8,WALL ARTWORK PLAN NORTH M Q TRACK HEAD-BAR COUNTER TRACK O Q LIGHT PENDANT-GATHERING AREA (qk/ Q LIGHT PENDANT-FAMILY DINING NOTE: ...__._ __..,...,.'- ------.... ._-...----` `_„ ---- ---...-'__' -- ........._.__._..___._ ..._-_._-.._ .._...-- -_.._..-------..._--`----... _._-------- ._ _-..._..__.----.__.. ._ --- _._ -_. --. ..... ---- .__..__ ._. . r _. ___.__._...._ _ __- - - -- -- -- ___ -_'-'---- ---._-__ . _ ------------"--- . _ "- REFER TO SUPPLEMENTAL DOCUMENTS FOR INSTALLATION GUIDELINES AND SPECIFICATIONS. ..... . ............ ..--- -._...,, .. - ._-.. ,.... - _.._.,, .- . _.__. _._...... ...._.._.._...., _._-.-.._.. _..... _,_-_-_,'r._..._.._.-_-__1_.__.1_.. . ;a. ---- _..;i _ _. _...., ,, .. a .-. ......... _ - ,.... ,., . ._-..,,,, ,, .. -- -, -.-. _- , ,_- ,...._ .. ......- , _. -_ ---- -, .. , ._.,_. _. _. , - ....- .. . .....-... _... . O i I ' I -_I ,4 11111111111111111111 I - ^ ii I'... ;,i :ii ! ,Iii.._ „ �'., I,' 1.1 i it, '_.. I, . ...I ;- -- -�) it VARALUZ'NEST PENDANT -_ -- y _- __-_ .KI ._.. _ _-. - =_ T_ . A \� ' ` if , II it 1 t- i I _ --t _ - % I 1 \ ; I I I "- •,.-.... -H_ i__a�,....��� .,- - -"-'J_. '� a:.'....;m -irl;il-;n.n,:® �..--r. ..,-�r_a. -. - ,ate-a®a. �. z�, .,..,Ili - � Y.�.;v - "sem>.�� .:yam..,...._. �...d..l�.�. - -...:el I \\\ /,' 1 �� 2 PLAN LEGEND jI REFER TO ELECTRICAL SHEETS FOR LIGHTING SPECS.AND CIRCUITING. \. ' i I !II I t m :i y illi i j \\ ' i `` \` I I , �..._.,-I I _I II ...,.I -- ,,..,_----ill 11 III :I 'I;; II �I11 I I " / I I n I n _._ _ i ! __� L . II \ � /,' ' SCALE: NONE __;.1_, _._... '.L-_ --'-__. II� ; 1 'a';_. ''ll ---'__..-Ii . ..._. Ini l - p ,-- - I'L- '11' ! I ,� I I \ ♦ i I �....- L_________µ._- _._- . __ _ }{__.__ JII _-.--___--.-..yt_____.-____ 1____.___-_.--I}_ _._._.__ _._ .. _� ___ �H _ I� _-_l i + i, I I LIGHT FIXTURE LEGEND -_! .:__._ . - rx= _ I I 1 \`\ i I 1 :1 1 r- --'1 : 711 " 1 2.01 11 it I - !I 11 i I .' ' I 1 6 \ , `, o ,0 1 - - , .L-- o \ 1:11 I I 1 1 i `, I I I nn a -(-{ i ( ,:i '', i1n ,.i..._,.,� .. TYCt. :I7 , + I :ill a �: .y_(..I P4 \ ,' ' I ,- E! r1 ; -e -- -i., I4 _ '`- r r ' \ 1. ALL DIMENSIONS ON THIS SHEET ARE FROM FACE OF FINISH LINE. SCALE: NONE \ i I`�� �� ; ,, h1 1i I:11 II ( f �1 ifl I (: I '._. .. ii :� _.._I IP_y_ 4 _>"7 . '; i \\, \ � \, ;' .-...........- ......, t _ ..µl . *FJ ....._... ....... .......... _ -. ...___... ............ /�,� I \ ..I... J ..I............ ._........ . , h , --Y�-- 4 Vit. ....I..r 7 r.q-.. {n.... Y .y - r -+Y� t"w � I''I- - I / ' �I -'-1T ..... - "-'� -x - >--I-- - •}�. IL. a +.. r ,.,._. " -1 _I1 o .. o _..,:7. _- I.. - -__.- ____'_' ' \ \ \ , \ ' , ' _ ..,_� -Lc�� ----------I __ -" - \\\ A\\v, v�V`. DIMENSIONS TO TRACK LIGHTING,FANS,AND RECESSED FIXTURES ARE TO CENTER LINE OF ,. __ , I I—. - - r -- -- - 2. �ivTI. I i i' I • ,'.,....I ! •...,; . .,; •) I i I 'III J i ,%'- ��A , A \v ,�', `,, ` I ., >-,.'. --,m II , ''`,. . Illi I II II : I ill ,iil i� , I: �� i!I `..11 �' ( ' i ? i .. I '' Iii �� v v v v if _ \, \ \ \` FIXTURE 1 ' I I t I . I I I , I I ;III � l �I _..- .. ..._.-- .. _.... . _ - .....,.. _ _ ._ .._.. ._ , .. ..._ ...: _ \.. \ ALL EXPOSED DUCTS IN DINING TO BE PAINTED. P 20 jp r E r( I { {; { { j�i jIIIIIIIIIIIIIIIIIIIII jl l I`t{Iil I 1 1 }iI I,+ I I }� I } I;...,_�t l I.,} .,.. .. }? _. ,�.,-., _ t_ ..4.._ , `\ �\ \ �\ \. O I F ---_, .__.....-_...__ �.._ II ili� ! Ii I III! ( � ''Iil ll i� i"I ' II; 4i i� ' Ii , I�i �;i ; \1 \ \\ \ ,\ 1.J .._ L.L i . 11 _ } ,I I \ 1 I i iII I i1 I! ' III il! i:; I . \ t' i - ,. \ I, ( k- I ( i :I I \ L _ _ 1 - _- I LJ . _ 11 L. - _ _ - - IL _I i \ \ I I __.. ._.__ ..m.,. ..-.:a:: '..�,w,..� -- ,,,.,•.� _..__�__ -_ . . __ _._ --.-- _ - _. _ _ -- - "' - = - ' " •' '' 4. ALL ROUND DIFFUSERS IN OPEN DINING CEILING TO BE PAINTED. P-20 I>j . _.. _ ..e,. ,!a --_. .. .::,,:.:.-,. -. ....---- ., ,...' ----- -- 1.......... _ -m.,, .,� "-- - ..�Iz;;_K- _-. ...----- �_- - 1 \\ \\_ �\\\ ` a �.. .. I 1.05 TY I 1.05 j �,\ \ v \ \ 1.os 1.05 1.05 1.J5 \ W 1.05 v I \ { I 1. I � \ I i I I 02 r rl SOFFIT H IGHT I A� P. I TY 1 TYP. A v \ I A � l ,v 10 0' .F.F. TYP i A i I v 2.02 2 1 ----- ` -- 1 �2 11 ..-- .....,...... -I I- -- - 3.0 _ 31,0......-_...-. -0�...... :..3;,�......- 3 3-0. 2 8 6 4z 6 12 t.1 ..____i;---1 7^7 , :. ,-.e- {- 1�� A A •v� v 5 ALL TRUSS BOTTOM SIDE OF DE EXPOSED PIP CONDUITS TO BE PAINTED W I / I : I V.LF. I ` I p I \. \ P-20 \ \ \ \ B K \\ I I , I A , ,-':- \ ! i � Ii " - �\` \ \ \ \\ 6. REFER TO ELECTRICAL SHEETS FOR LIGHTING SPECS AND CIRCUITING. r _ I , II , I ail \\ 3I � , `, C U' � � i I I \ W cn .-_.. ._._. __ - _I / 111iii - - > } /!-- j, -M;. i \ [' _..... .t.-,_:,--• : I i i \ \ ':1 I ` It� i i \`I. I Z _� _.__ 1 - _ ,, 11 . , 'y - _ " \ _.._ GALLERY LENGTH ,, ,1 . /, R :" \ \\ t _ _ { - 2.02 .._ _ - _ .._._ - lr^ ' y \ d ; , ---- t 7f-. �" - - ` ,31: 61,, . �,r -� ,5�= I 1 1 , GENERAL NOTES _ - y 3 z d �' 3:0:: 3,0'-. 31.5^.- _3:-0. TI.3'-0" 3'.0_ T 3'-0" 3'•0' - - ----- .._.._ . 1.05 __.-..._ 1.05 ` : �_-.;.., - , I. % I-— - _1- I ��41_� i ! �► SCALE: NONE s115� 1.18 _._-. t, A , It ,. 5 I - ,I y` r ;, "Heron Plume"-RESTROOM WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC W ' - _ I--, .*, ___ P-13 PAINT #SW 6070 Heron Plume SEMI-GLOSS FINISH � Q ( - I . _ __- . . I .. , . y �[! 1.05 P-20 I ., . Jjt ;' _. _ sr xrx` CONTACT:303-902-7239 'I TYP t; _, ; __ \ '\ \ < ' \ "Lucent YellovJ'- PATIO WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC N iI i' i. r' ? I`, ': FAMILY ININ \ •a ,, r '. ,. i .;I,�_• _ w P-14 PAINT #SW 6400 LUCENT YELLOW SEMI-GLOSS FINISH I� : D G ' \ \ ''I..-, .i __.. ,... - I.: ,.`, r%^� �: I , ,: r \., ` "i1> r r s ,I ,. j ^. T ' `\ \ < \ , \ \ ♦. +r'S�`. \ 1\ \ ',J �� `4, I' i; ^c,_ : .5; *. N:! I \ : N .1 I I -.;' I I t .''y, j `.,,I ^,' \ \ \ ` ',.'\ ,.,\ h\..... ` \ \ \` ;� T,\ tet.{meq C� -+____ , -q .e I I \ \ \ `, \ \ CONTACT: 303-902-7239 t\ , \ _.__ i1. \..... 14 \ \ \ "--,-----' \' \1 \ \ \,\ \ ` y , Tricorn Black"-DINING ROOM CEILING SHERWIN-WILLIAMS LOW VOC WATERBORNE W .:- .. ..:.z.- !....., i \ ( '- "---, ! ' 1.08 .\ \\. . \ \i•: `\, \ 1. 3 �I { -' \ \\ - . .'�. I ,/ I \\ \ \ \i \ \ I` \ \ ;r,_ P-20 DRYFALL PAINT#SW 6258 TRICORN BLACK FLAT FINISH I� W r'�;^ i \ i. \ \\ CONTACT:303-902-7239 /'�� W > .-. ,\ I, + n- t •,- �if ' ' : , r . .,, _- .,,. ...{. x_._____'-.., . ..__.-- -. \ \ 1 .. \ \ (} T ! ` 'lam\4r ♦\ 1-.L. :....; I C l I \ / ;'\: I i' ,�, I f \�\ ...� \1 \\'\ \ `\ 'h.\ V `I� 1+ \\ "w --1\L, 1.05 �- ,,.,_. ( _.,, \\^ ; \ 1'`\{ \\ " t !Y '' \ LAMS LOW VOC WATERBORNE DRYFALL u l,k I \ T\\ \ \, \, \ \ I \ I : , „ ; "Grizzle Gray:,-PATIO CEILING SHERWIN-WILLIAMS � wO W \ \,i L _... .--{ . r I TYP. I I a _ I :: Y, , , I \` \ l \ , �( - I I 1 Z.__ I , I ; \ \ ''K \ \\`\,\,,` \ :.-- `\� \ x P-21 PAINT#SW 7068 GRIZZLE GRAY FLAT FINISH m !yam _- s _ _... - _- \ \ �. O W \„ -t-- �#' \ �( ` - \ CONTACT:303-902-7239 - : , L....- 1.05 I \\ \ \� \\ \\ \' \ \ \� \\- L.L fy- \ \ \ \ \ \ Q� - - -. \ \ t \ \, \ I! wi �� I '>t�,,..fir/ _ ` .../d i_. .,.. ._-..;R I 1, `\ \ \ �\ \\� ,. . \ \, \\ `� \. I' ! ' , -:, ... . _.... ---_ _ - V V \ \ �, , "Chelsea Gray' LOBBY SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO OC � '■ �■j --I-- li : . \ \ ti \ \ ;`1 \\ '- y "s P-30 PAINT CUSTOM MATCH BM # HC-168 CHELSEA (USE FORMULA IN SW SOURCE)GRAY cn Z I- \, I / l I i \ X \ \ \: \\ i \ \ \ \: t I (- ,S. I - , i t `-- F- - �-j j-^-_. `. `t. , ` I. ` \: , \ _.� \.�` { ,. ''*�' - ' ;. tom . Q 0` \ I I '" EGGSHELL FINISH CONTACT: 303 902-7239 Z \ i / \ _-. .._."--_.-- .. _-.-._--_ : / ..-'- \\'� `, -___.--- -.._ . . --..-- ': ---.--. .-- _-... _._ ..-.- -'_-- . - -- - \:� i\ \\ I ! "Extra White"-ART WALL SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC � LL ', Tom., .="; ,` l '---- �'^:•: \I s .._: ...... ........._. .r.j-- \ .\ \ y;., - \ .. "- ..., \ ' \ \ \ \ I: "! ` 'a K ~ N ♦\i„ . � i O °;�? ( 1.05 .T....T T„ f -r..... ;p 7i, \ ..,- \\ \\ \ ,, L. \ P-31 PAINT #SW 7006 EXTRA WHITE SEMI-GLOSS FINISH O O W B� / I r,, ' P-30 TTP E:::' ., _,--.- 1.05 % \ \,....- \"I\, I\ '\ \ \ \\` \ ` , '\. \ !',i11 ':' . j \ ' CONTACT:303-902 7239 , If. 11 O , \411111" ♦ `'✓ ^, \ , V I --' IIP. I. \ - \ 'T \" 1 \ \ \ \. 11 \\ ] t,is V� }� i h'. -'-'! i I: \. ___._ \ , "Approaching Storm" BAR/LOUNGE SOFFITS, MURAL SOFFIT SHERWIN-WILLIAMS = 1.14 1 -... .. __ J 13 L ;:; , I\ _ \,''\ - : \, \,� \ `'. \ = I P-32 PROMAR 200 ZERO VOC PAINT CUSTOM MATCH ICI # 1379 APPROACHING STORM Z a \ .t !, ♦ \!. QCT'\ -9 \ \-. �; TYP. ` i I I 1 `• - 'i ! \ *\ \, ' "GLI ', :1 O (USE FORMULA IN SW SOURCE) EGGSHELL FINISH. CONTACT:303 902-7239 - - 0 I v...� I........ . ............. . -... ......-. _...... ...-::.. \ _,..-'I -t'K- it v -\` \ '\ 1 ,'... .,, \`\ \,I' ' yL,i1•a CO O I I yG \ \ C ULL I .... __ \ \\\ \: \ \ \ \. -\ - \ , ` \" Heron Plume"-RESTROOM SOFFITS, CEILING \ __Y > Z I VESTIBUL I ;_-.. -__{ , ___ _.,.. ._. ._ y_, --- i ` - \ - ?' , _ _. \ " .., s \ P-33 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC PAINT#SW 6070 HERON PLUME > W I i 1.08 : EXIST.SOFFIT ,: __ I_. (__! + - -- ._. \'\u \ O � N Q W - '•- \ •_T ; i SEMI-GLOSS FINISH. CONTACT:303-902-7239 J l O l TYP ,I X'-X"A.F.F. I t 3 I \ 1 \ \ \- \ \ \ \ , -� r._, 1. Y '\is O ^ LOBBY j I I }\ \ \ \ \r OB/EXIST.CLG % - i i I I ( I I i ; ,I. \ `, \; '-\'- I ; ` ! \; '} {_ ,..,.'�__' 1 `� , .' I: �a `. - � ` ,t ``, ?.i "Worldly Gray"- EXPO DINING SOFFIT, RESTROOM HALLWAY CEILING �I \ \ T\ \ \10-2 A.F.F, OZ - �' .,r T \ \ \ `,i ♦ '; \ P-35 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC PAINT#SW 7043 WORLDLY GRAY //'���� O O (nI ! ! i _. :I I , 3 -1. I I I , 4II r ,\, •\\\\ -,, f; \ v!, y\ \ ` _ , I `\ \C \'\I\ \ - - F ..' - LL ,- !2_ I I : I 1.05 \ ,,., \\ S \ - • :I I r �\ CONTACT:303-902-7239 't IE, \ `� '� O SEMI GLOSS FINISH C I B/EXIST. CLG i \ \ \ \\ 1 , \ . { i P-30 ! ! I P 35 _ \J \\ z _ \{\ -� \ �}\, +. K� C ,'� \w� 10'-5 1/2"A.F.F. I - .._ .-._. ...L .. i JS. ,\ \ , ' \ \ C•K i ml.,., \ \ u 4 --' \v - .\i t a 1 a `% ;� x aa _. `. I 1, 1 1 ,�,�\ ptl \. \ Q \ \ f k fi x \ i!. l \ !, /1� O aC w ;P I ,;.. , 5 ... ..-. Il \. ,;\, -k^:. ., . '`, "`\\ "' \ y\\ \. '`' i`�. - -\ Y \ ^,�\ \ t s,,t +$1 �4:. iSV\y- \ i� o_- n{ , ,,,1 i.%,d:fy �, � - i- t \\ '. .I '1 CfSa `I, 1 j� \.:.Y,` I'\u " it,1\;� ', __\ i 1 u v O w ❑ .. ` a: , - i, Q - - ;.-- 1 , ]IN_ I : - \ FINISH SCHEDULE ._ i \ 1. TYP. �.,�- ---i �`%. I ,! \ \ 1 4 _ w m }} : -' : -, i 'I-%'+ i . 1^t ? , 4 `II` '\ h'`�:, \ {� `. `.i\ i \. •'c'ty� -s ,Irh r\ ..\i \ ` '� _ -. -. _ (� '� N a' 411' ..., � ....... .'...~ ........ 1 , . . 'III, , 7 `\ \ ;:: >~ \ '.; \` .,'_�\ ", \\ \• \ . ' > ib 'a � \ 4, ,. t , ,I ` � SCALE: NONE �"or.: ( i I ',^ Y 71 e :III,� '. .. .. I _ yIF' ` <J ' ! 1.05 :. I,' a �',,, 3 \ "'� ', i'' ,\ \.\ �\ \ - \ t�'{ ` -�r\Iii �' ,� \-'-h ;44 a ` 9 c m diw� 1.14 l ,�. z a. X. \ J, \ ) ,�I \ \ . , 1 ._. , TYP. B , z4`1111", 1 � -I.f- g `I w ::.:'I,, \ ' , \ (\. , \ja`l, * ., ,\, y. sk -_'4-'l. - ]..I m _ ,, �..� ;, . \ �, ; \ _ (PROJECT SCOPE): U ,o < - _.:.. �----::. ," 1 Itet.-Til-s_a ; .. 1. _--_-...., � \ ,I . , :\, i 1 ,\ ,\: `\ x,'=• \ _� 1.XX �o Q I i , v i : K. : �, 0 ' jIt �� �� ,..-.,._. ., (� It A _i ,v[ •.V 11` ` } \\ 1V IV , v \ \ 2 � yam ? C � . v v 4 c... SF �,: 1__. v y r :_ NOT IN SCOPE OF WORK C � _ D a "• Fi 5 Bd 03 I (i; v yA\ � A =--t. A� " ,{V v A \ k 1.01 NEW RECOMMENDED TV LOCATION. PLAYNETWORK I OTHERS TO VERIFY. �Q rJ a �ql1. { / , I \ � 1.10 I . . � '� `r. r 65 it' -.._ _ I 1.02 NEW ART GALLERY TRACK LIGHTING. REFER TO ELECTRICAL SHEETS FOR SPECS. T7/7 t, I1 : / ., \, _ 1.os I j fi\\ \ I . ... xI� A, \' ` Y 1 '1 \ \ , , I TYP. \, I \ \ t " •-- \I \ ,_: . : \1. \1I \'y 1.03 NEW GATHERING AREA LIGHTING.REFER TO ELECTRICAL SHEETS FOR SPECS. It _ i 'I ;i _ I , ...u.,,. I I J ,.,i s`y. -1"-'- , .\ \ \ \ \ \' ♦J \ / 1.03 _... _ }, ! 1 v \ \\' \ 1 $. \\\ O - ___ .....-- '----... \ T \ \ it - -_„-1 .-: I--.. :�-.r -4. �. ..... I `>. \ \ "., i ._ ,\I L \\� ki I L. .\'\ \;. TYP. _ I ---- -- 1.03 1.05 ii is \ \ 1.04 NEW BAR AREA LIGHTING.REFER TO ELECTRICAL SHEETS FOR SPECS. ` I i \f r'- __. 1__..,____._ _ _.___� .; \,, ,,....} \ \ \, \ - 1.05 NEW FAMILY DINING LIGHTING.REFER TO ELECTRICAL SHEETS FOR SPECS. 1.03 ' \ \\ \ T11 �\ \ ` s :• , .I: ,:;;ll� \ \i_'_' \ \ "�:y' \; I t ` " 1.06 NEW ART GALLERY SOFFIT.REFER TO DETAIL ON SHEET A5.0 I 11--- -. _ .-._.,_ , __ ., i:' t2 � i . .: \ \ - ` \ \ '\. EXISTING TRACK TO REMAIN. EXISTING LIGHT FIXTURE TO REMAIN AND RE•LAMPED. REFER _..,1 A I _j � --- - -� _ - 1 I - . v ,..: 4a y tiv A y 1,I A ,z 1 ?::r ` :'.. .. A A 1 l v `C ,� .' '/ ' \ i j'. ! AI '... A� ., c(. A. A .. A `V i 1.07 , 1 1� i I1 I 4 I I \ I` V A `, V�' TO ELECTRICAL SHEETS FOR NEW LAMP SPEC. GATHERINGDINING v �'', \ v v :-_�a , y+ •_„ A , ;, iA, t \.� A EXISTING CEILING LIGHTS TO REMAIN&RE-CAMPED.REFER TO ELECTRICAL SHEETS FOR ti A ...- _ .-_ - J......_---- - ._ -�..__.. _. ...._ y A y ' { \ V T 1 �. �: I ^,A,V ; \ .. v \ 1.06 v $ -� + 1. y GATHERING 1 .FAMILY v �. A. .i �� v v NEW LAMP SPEC. Revisions B 03 1.03 i 1 O4 P 20 .v . "�, y ,, vA v 1 Iv \ \ v , v AI a 1.03 - °{.� :< i.. i ! v v .,: .1 ' -^ .v ` _ , ; `. A l , '-.-„ I ' .r _ _ y, v � a S : ;-Ty`.: ' ISSUE FOR SCOPE REVIEW T . .�:� _ - II}�. d ,., ,, _ > - - y v v , , . ::,r. . , y 14tA s y 1.09 NEW BEER BOTTLE CHANDELIER. m I `' ` 'J i1 I , ' '„i r � • i j `.',I \.,'` 'V ,• _._.`;;._ n ' ` '3'4a.,'s.P::'Y.l''t \ ,.1 V .,:i' 't, vl{ ,LAI 1 :I .:y ,, i ; �04/24/14 r'.. - )7 'i..... . ., > ^.,,��7� ..,.,a,. ....... { .-.... \.......; y.......:,� �. \ , \\"4k I ,,Y\,.-.. , 1„: \ . 'WM ,.n.:i j:'Y , .:a, 1.�..... .:h).,':.. ., TI, Ia'\ ',�'i' Jr n a --: -(� Y I, 'I (9 'tT.. , ! : I �,, Iv, vv .., {,, ,.;., ''I. y :, ,., ,,-'.'s.7\ ,:{.;...: A ;! y 1 I y TvSI I ,u, s.' �+. ` C, ISSUE FOR LANDLORD REVIEW < I : _ A , v v v r i; it, 1 _ _ 1,10 NEW GATHERING AREA NEST FIXTURE PENDANT. t1tCY �. Li ,.< 'v 05/16/14 0 i t 202 \ w 1 I ._..; i'I ,: .. -,I• I w '""i,,. i i .I .,.�� A i; ' ,, 2i �., - , ' a'`, .. A ISSUE FOR PERMIT REVIEW y ""' v \ ! :, ` 1.11 NEW BACK BAR LIGHTING.REFER TO ELECTRICAL SHEETS FOR SPECS. _ ._.. ... I 'f i.�.w 1 :: - V v } \a- h\11 ,L..A i 07/22/14 . . T11 I '■r I ,'/ '� �, ''t.��,:.:. . t �`� \ I� V''^i � \' _V � � ov 1.12 NOTUSED, U ...... 11..._. .......... . ........ ,� ".. - i` - w I HALL ,. , . . ` ', A�. v v, I,, III I I .,r i m 312".._____-t._. 3 2;. ._-3 2 �_... 3 2T 3 " _ ____ 3 24 m i ( - l O6 `�, A A A v A 1.13 RELOCATED N BY AV VENDOR. G.C.TO COORDINATE WITH AV VENDOR INSTALL DATES. K :. __ , : - .t , , r� vV�\. , -_)_ .I,_,,.,.__. i f- i I. ................ (� _.. it vt'V� V '\ \� \v v v V\ v .--..- ...... ....._.... .�,.. ......- ' _....._.__--.h"� .. ...._.... P-35 V ` , A ^ ry A� � 1.14 NEW LOBBY TRACK LIGHTING. REFER TO ELECTRICAL SHEETS FOR SPECS. �' ";,..: - -:..: ' ..� I ( : 43 � : 'S6' 1 1.08 s .,,\ \ v .I`, .v '.` , I _ _ _. 14 I , ' _ I i I �� _,. � TYP \�. v' ,`iv`y AA v v\ J, A "v"�, z i 1.15 NEW LOBBY AREA NEST FIXTURE PENDANT. '. _- - ns < _s ,o o O ®. P-33 u v y,v '. v v ' 1,16 RE-LOCATED EMERGENCY LIGHT. _ �� a I ,�: : 1.04 \. A,`\tv V` ( I - �� p k _ ;i h�^[4ya1 " `� ...............1.._ -....,.. ..., ..... w 1. : I BA'R / LOUNGEI ` I 1.0s 151- 5 \\ \`\ '`,I\ \ \ \\` \ �\,\ ,t, It" ) .II II I ,! : .w_ 4.._,_i. ._..r __ai - ,, - : V.i F>, `. A v v A t _``v � VJ 'T . >< Av i [ .::- i t l :. 2.52 103 MEN ': _ - - --- _ -_ J .--- --- - _, v" ` DEFERRED MAINTENANCE): D A I r ; I 3'- : 3 i0 r 3 0..... __ 3,0-..... .. ._ ... . 1 ._.......3. 3-0 P-20 � ._.. I. ���. i\� �` � 2.XX ( 1 O R� '� { ' I •-, I ` __ -_,+'-.I .. _ ........., _- c sr -1... - I ,'1` ''V 1 \ Iy. I!' i I:I �.� '�' T S SL_.;1 {08 -- ..- 1.08 \ \ ` y ^� � Tr:i 2.01 UPDATE EXISTING PATIO LIGHTING. �Jf 1 } v \' \ I� v III `� F- 11 - -- _ - -- -� -.. N A.CHIPMAN .. '`' a:. `ci"'j„i< ,,.:nr r,ar-_ _ .. ... : ,.':r.:: k:,--;�... -- .... TYP v � - V i \.�A yv \' :..�i:, i j v,/ JOHN C� ._..., __ _ . .... 1. 4 1 " rcl( _ V ;' •: ,..,,-.< '�?",.:.�`l., '•., .. _ _ _ __;,.-._ t a.X.. A '...� x:-„ y ' 1.04 :4 0 �' - A�\ --- --- - _--_- .. _-_- -_ - .. 2.02 ADD EXTERIOR FACADE LIGHTING z I I =' , t' x:' ND.3653 W i mm ; 1 a;,. { :I ci! Ii •. i : �. . . .:. - . . . A_. v - j ---'---- --..___ - _ _. .. I , - " ,,. -n v. Vii. 1.08 y- V'\ '_ _ I TYP. �x 1 WOMEN H { �, k,,, T_ A ; , TYP :- _. ...' v \ L ... .._ __, ... 107 _/ ,, v Es,1L .� ;:; _ ,' � ,_ ,. UES PLAiN: ar `n.--.,•.'I I;i? i �w LL - 1.11 "S� { . v ':v \ h \ ...\ V A ,�.,. l\... .,. '\ vv g I i._t .--..-.. �.il v r I ! --I 1,11 I I . TYP E ✓IIII / � t I - - A A 3.XX (ADA SCOPE): ._ J --- ----- '� I i 1 �\ \ -.. T s ,. i i 1 �S� 's I % a I' - I .. h __ A 3.51 .,ur7; .._.. _ __- ...- P 33- .. ,-- v \,- _ S ..._ _ ._. .. 11 11 tic 11 d �_� _ . _ _. . . ii p` i ... ..... {+ / Ili i ®t \ ,,,y - ...._..-... t I I __.,-- L� �' ""- , - t -'-'' --" '- -' i , HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- .._ ____.._-...__� - - - ._ I __ _ __-_� w I PARED UNDER MY SUPERVISION AND THAT TO THE BEST I 1 I r OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES. . ; i REGULATIONS AND ORDINANCES OF PORTLAND,OREGON __._ . _____ ___ ._ I RELATING TO STRUCTURES AND BUILDINGS. .. ,..--...._. ...-_..... ..._...... .-....- I I S I 1 I I 1 0 i ARCHITECT ! gDrawn By Checked By m I , a Scale Date h AS NOTED 05/16/14 sJob No. ' is Sheet No. REFLECTED CEILING PLAN 5 KEYED NOTES 9 SCALE: 1/4"= 1'-0" SCALE: NONE A2 , 1 I , EXISTING --------� 6'-0" 6'•0" 8'-3" DATUM TRIM 6'-6,12" LOW-VOLTAGE WIRING& V.I.F. 8 3 314"CONDUIT&4X4 ______ , __ V.I.F. (V.I.F.) EO. EO. J-BOX BY GC i I TRANSFORMER BY VENDOR 1v� 48th PARALLEL I I I CHALKBOARD FULL HEIGHT �� DATUM TRIM I I I LOW-VOLTAGE WIRING w DECOR PAINT WALL ART ( � ------------� MUST BE -------� I THRU-WALL BY VENDOR ( ) \�U HORIZONTAL 120VAC/20 AMP j I I I MURAL CIRCUIT BY GC L ¢ 0 ❑❑�❑ - - 0 o WIRING&POWER b > > 0 EXISTING ' I I j j SUPPLY BY VENDOR N W L-_--__------J 8'-4112" " o is d io Li o LL CHAIR RAIL `------------ ---J N LL N LL ] _ d TYPICAL WALL ART BEER MAP TIN TACKER CHAIRRAIL (V.I.F.) � YUMMM SIGN m ILL: D-300's D-303 D-304 TILE BASE D-200'S uww TILE BASE SEE SCHEDULE A - B - _ A - B - 2 DECOR ELEVATION HEIGHTS NOTE: REFER TO SUPPLEMENTAL DOCUMENTS FOR INSTALLATION GUIDELINES AND SPECIFICATIONS. 3 VERTICAL ART WALL ELEVATION 4 LOBBY WALL DECOR ELEVATIONS 5 NOT USED SCALE: 1/4"= V-0" SCALE: 114'= 1'-0" SCALE: 1/4"= V-0" SCALE: 1/4"= 1'-0" FT 77 1 (PROJECT SCOPE): . .. - _., - m ... �._ _ i......... C l ' - - © , ❑ ❑ b" ❑ \\\\\ \'\ SEE VENDOR ART LAYOUT FOR ART PLACEMENT ON ART DIVIDERS. 1.02 SEE VENDOR ART LAYOUT FOR ART PLACEMENT ON SOFFIT. SEE VENDOR ART LAYOUT FOR ART PLACEMENT ON VERTICAL ART WALLS V AV ' vv �`v Avv air i � a o o AD \\\ 1A4 NEW RECOMMENDED TV LOCATION. PLAYNETWORK I OTHERS TO VERIFY. LJJ{1!U \�\' \ Q\ EXISTING TV LOCATION TO REMAIN. PLAYNETWORK I OTHERS TO VERIFY. -- SEE SCHEDULE FOR BEER TOWER SHROUD DIMENSIONS. - l I I \� \ O I; 30 q;200 1 D-30 I I I I I I I +d (1 I ( !I I I I I I, ( I I I III I ( ' I 0 \ \ \ \\ \\ \ \ \ SHEFFIELD BRONZE CHALKBOARD PAINT MODIFIED ALKYD RESIN#986 BLACK CHALKBOARD PAINT LL.I Cn l l a i I I , I! ii \ SHEFFIELD BRONZE PAINT CORPORATION i I I( 1 I if I i � ! 1 4-i 11 III I I i f of \_' \\'\ \\\, \� \\ Z + t I l N i I i i .I'! , :! : I t! I v A v A A 1.08 RE-LOCATED EMERGENCY LIGHT TO AVOID VERTICAL ART GALLERY. 4. L �! L a i t. L J L II _ � h L 'L1SII �� j ; g ; V\ v , v^ v y D w j _ ? �! V `` `x v v 1.05 -1.09 \�\\ \ \\\ \�\\ 1.09 INSTALL DECOR TO AVOID CONFLICT WITH EMERGENCY STROBE LIGHT. (fin _ V L -- - - 76'-2" \ I ------ -- - ---- ----_ - ------- - - V.I.F. - - - -------- ------- Ln j - \�\ \ \ \ \ \\\ j NOT 3; 3B -� ❑ G.C.EO INSTALL ALL SIGNAGE. REFER TO SUPPLEMENTAL DOCUMENTS FOR INSTALLATION „ \ \ J 71 is -_ __ -_. �.-.___ _. - - ___.. - A2.2 GUIDELINES AND SPECIFICATIONS. (V ---=- --- '-- 1� ---- ----------------------------- ----------------------------- - __ \ 6 ----- \ DECOR KEY NOTES uj � 1.02 , 1.04 ` v \ \v A\ v \\ \ v \ \ ��A SCALE: NONELu 1.04 j 1.05 1.05 y'v vv W \ \ \ vA � ,� wv" v \vV CODE DESCRIPTION u W�/ , 1.08 /\V I I I I I I I I I I I I I I I I A A A m \� - - -' TZ;F 'As � `m \ \ W \ \ :., \ \ D 201 RESERVED FOR FUTURE USE LJ. \ FAMILY DINING ` ` . A V v V .v � ,� ,� \\ �vv,.; I � �h , � yv v,v RESERVED FOR FUTURE USE � \ \ \ \ \ \, RESERVED FOR FUTURE USE 0 ( 105 v v v x M -204 RESERVED FOR FUTURE USE W r,,.✓" ..i ,�' .v. C" I r-..-.__-.-_------`"3,v' ^ \., v V v � '.V I ` v ' ,, ' \ \ v ` V v vv i :J x!�\! I . 'v�v v� A i RESERVED FOR FUTURE USE cc = \ \ \ A,, `v \\ \ I \\ D-206 RESERVED FOR FUTURE USE Z Q � J v V v y A ❑I � y n, .L v , u I \V RESERVED FOR FUTURE USE >. Q I.1- 1.05 1 3 Vv vA \ V , A�,. .�'. \ \.Vy\vV A\A v A y.\ A v I �.1 1 IIT A � ' I I 1.01 \A, `�` v \ y, A v ` ui V vVA k D-208 RESERVED FOR FUTURE USE cn \ V �/� \ VJ A \ v VA \ \ D-209 RESERVED FOR FUTURE USE \ RESERVED FOR FUTURE USE - 7� S. D 201 a , \ \, IF - \ \� x�� � n ` \ \ \ '\\ \k \ 2D DECOR SCHEDULE , : \ ` 4 SCALE: NONE VESTIBULE LOBBY ...._ ` a...• -:v st-� .i� - _'_ \ 4L . - �__ '` � � i._..yam '; z r'�? ` �.i 'a c m , , l o CODE DESCRIPTION ® 7 a= ART WALL IN LOBBY: SEE PLAN&ELEVATIONS FOR DIMENSIONS „ r ,` \\\ { -\ \ ( v l \ , \ T - _•, \ ' X ' I \ \ i BASEBALL FLAG: 60"W x 40"H /� _ o ._ H BEER MAP TIN TACKER: 78.5"W x 42"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) � Q °- !I1; CHALK °-`, t \i\,, i,, { .'N. \ \ { ? \ '•n, &-' .� t.+ D �. ,\-T �� \ �\ � \. .- ' �� `\ ";\ = ,,\ \ \.. \ I 1 1 • `\ I" ` '\\\\�\ r Y I� ,� \''_ �\, '`I - YUMMM SIGN: 100.5"W x 24"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) N v v D 304 - '�II �.....�_. -'-•`t � .r'r j I f \ { a'. \\\ �x�\'',`'\ ` .`` i ill .,\ \, I",, \'. ''-!" \•s� ;: I ^k.....'.:...... , , \. \ ,\ } '�,'I � v � �'---- i\._ ,I D-305 PAC-MAN CUBES: 13Wx11"H EACH �. a - __ \ $ \ m j A2.2 A2.2 1 ` \ NOT IN SCOPE OF WORK \ D-306 WOOD BURGER SIGN-WHISKEY RIVER: 48"Wx40"H . . f j' ..J_._'—'.._, — — I \, ' \•``, > ` ,,\\ � � WOOD BURGER SIGN-BANZAI: 34"W 46"H ry a !, r .•1 I 1.U1 I I \\�, \ rly^ w \ \ , 1''� } \ \ \ \ \ \\, \`,. 1. 4, .o \ D-301 i , 1 > _. ''.:S,I `i .\.\. '. . \\\\\\�'• !-_.. \.,\\ \ `� -:_' =,_,..tli \` �, `' '\ \ \ \ `\ ,i WOOD BURGER SIGN-ROYAL: 37"W x 46"H s ti GATHERING DINING _ _ .. \ \ \ „ # \ \\\\ \ \ ,\! Ii \ .\ i4 \ \. \. WOOD BURGER SIGN-CHOPHOUSE _ \ a { r 104 WOOD BURGER SIGN-BURNIN'LOVE Revisions ISSUE FOR SCOPE REVIEW l ^J..! \i \ `\ '\ ^ t. ,� \ y\ t I!, ! \ .. `l ` !J7 { \ \ ,`.\ \ \ z , \ „ \ L�04/24/14 , ''. , : \ , ' I "��'_ \ � \ . ' \h t.� \. \\ ',+ \,1 t. \�`� ISSUE FOR LANDLORD REVIEW .\ \ .,,;t .. E 8 TRACK WALL ART SIGN FOR THE PEOPLE: 55"W x 45"H 005/16/14 -\,i l \\ n\ - #; : \ ✓\ ._,1, 4 t PERMIT REVIEW ISSUE FOR 8 TRACK WALL ART-MARILYN: 55"W x 45"H 07/22/14 8 TRACK WALL ART-UNCLE SAM: 55"W x 45"H �.➢` LICENSE PLATE GUITARS: 15"W 48"H(AVERAGE SIZE) L� 5 ^w, t ti v -�A A V \ ,v\,tv , ?•f. v `� y\ \� \ QV v A.. vI\ V \ V `v \ \ % L� o --- - 1.05 \ A_ A, _ v V\ V v�� V A, A � ,I VHS WALL ART: 48"W x 48"H r VHS WALL ART' 56'W x 44"H : I 3098 ` "POP ART"CRAYON ART: 24"W x 24"H EACH m ! 1 11 1 1 1 1 I I I 11 y iv v vv v 1 �� \ �, - \ t _ \ \\ . J D-311 FLYING R's a � ---. D-312 LEGO SCULPTURE-ROYAL BURGER: 24"DIA.x 22"H \ 71 �\ e HALL \ \ \ \� \\ \ �\ \ \ 'S 3 3os- I \ \ \ \ \ \^\ \\\ , LEGO SCULPTURE-BURNIN'LOVE BURGER: 24"DIA.x 18"H JOHN A.CHIPMAN C[1 I i ' 1 ( \ \ \ V v` A�'v A �`•,A v �- .;A y A<A. �v \ -3120 LEGO SCULPTURE-FRIES: 13"DIA.x 18"H � No.3653 `r \ \ \ \ \\ \ \\ \\�\ • DES PLAINES,IL • - � L�; ,11 LEGO SCULPTURE-SHAKE: 15"DIA.x 30"H+5"STRAW DIMENSIONS STATUE OF LIBERTY STENCIL: SEE PLAN&ELEVATIONS FOR _ / 1.09 ! i \ \ \ \, '• \ \ BAR LOUNGE ? 1 MEN �\\\ \ \ \ \\ r D 314 BEER SHROUD:NOT USED I 103 \ \ \\ I Ei 0-81y, WOMEN �" v _ y, A ( D-315 CASSETTE TAPE WALL ART: 56"W x 57"H O 07 - \ - ' ! Ip HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- ' ----------------------------------------------------- -- rT _, _._..,.....L _. D 3158 CASSETTE TAPE WALL ART: 43"W x 45"H I- ,— , 1 jl .,i --y \ V - PARED UNDER MY SUPERVISION AND THAT TO THE BEST �..._.- .:.n_. _.---- _ -" :... „ -a - .:.- ---T-.c-'-q� .. ....._...._. Y---= .-_.__ `�,V; �' \ - ,- OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, ',I `� , -`�. '' .!.. A. -._ , ��-�"V^i�. � � �, ,...'V -.: •. Ir.:'- : _ _ _ ._._..1 _ REGULATIONS AND ORDINANCES OF PORTLAND.OREGON 1 v 3150 CASSETTE TAPE WALL ART: 35"W x 36"H ' ELATING TO STRUCTURES AND BUILDINGS "- � NOT USED a � ♦ J ARCHITECT JIMI HENDRIX RECORD PORTRAIT: 48"W x 48"H s ♦ III - I'01 / Drawn By Checked By RED ROBIN BLOCK LETTERING m Scale Date O 303 3066 8 \ AS NOTED CSC.) 11 _ A\ 05/16/14 771 71 X� � . _ .. 1' ---- " "r REFER TO SUPPLEMENTAL DOCUMENTS FOR DESIGN INTENT, Job No. a .: .. -r ,N N INSTALLATION GUIDELINES, BEST PRACTICES, SOURCING, SHOP m p Sheet No. DECOR PLAN9 3D DECOR SCHEDULE A2 . 2 9 SCALE: 1/4"= 1'-0" SCALE: NONE SYMBOL DESCRIPTION . _ ITEMS TO REMAIN NEW WORK ITEMS PLAN NORTH '`�--`S Q) 11 I 11 11 _-_._ _._._.__ .__.,_ ..... . ___.__..,___ __ __ _., ``, E r.: a `1 iD ' ' IQ I� I. D' v �,.. _._.____ ...___ ...__...._,_ .. .__.._..._..... _... __..__. i _ i -'-------.... :v..._...........__..._,_un_......_...__s_.u........____:_---.._,_s._.._.....___._ E .x11 ._v..._::.::r_za__x:._... --.u�,... .._,-...... �.- ,... .. ., ..... i ... ........ - ... -- .. ..... ...._._.... b.=.a.._ ..- -..:.J_._> ..,___..---.>A.,t.r...._ _...._v_.._._.._+-u.__,_s_........_._...._s � A �� � PLAN LEGEND �' \ �\ \ ` \ SCALE: NONE `,\ `I-, i o%_�� � �'�_moo ``\ VENDOR: ARCHITEX �11 ! � I a <► r a � n �F�2*_ o—,:D �� I1 3 EI ,, ��� CI I .fir `�\ \ \ FABRIC: CARREL-GLACIER ,......_....�. _::� __: tf -�- - ,4:- i f .�g_,�a oy5"' , _ 1-- �' i _ - ` \ \ \ FAB-1 LOCATION: BOOTH BACKS IN BAR/LOUNGE r------ i a \L u t \' \ ', u, ... -?� <,- . I I•--ter-: ! 1 ;:,� w \,\\, \`\.\`\ 4``, \ \ \ \, \ (INSTALL PATTERN OFFSET VERTICALLY) (p ' € a , •/' =l 1. \. \ \ \ \\-` I f _ - I— I f� I f� �1 I� �l _r _, R ta, \\ \ti\ \\\ I 11 _ \ \`\ \ ' e`' VENDOR: ARCHITEX I I I I I I I I III 1 1 I I I I 111 I I 1 1 I I I I I I I I I I 1 1 .3.; '. 1 '\\\ `\ \ \ \ \ I H • a \ FABRIC: MAINSTREAM-TURQUOISE I: I I I I I I III I� I I I I I I I I I I I I I I I ` I I I I I`I I I ;'<. ::v: \\\ `\ \ '\ \ FAB-2 € I :-I \\ � t \ �\ \., \� \, \ \, LOCATION: BOOTH BACKS FOR FAMILY DINING I I I €I I I I I I I I I I I I I E I I I I I I I I I I I I10 \ \ ,\ `\ INSTALL STRIPE PATTERN VERTICALLY 1 J L J L �I ,I_ L J€ l J ._._,�. I I L J, J L J L J L B y\\Av v `y \ ._ „ , i� i FAB-2 .` \ ``\\\ \ �`'\` \\. \ \ \` `` ` �` FABRIC: RED ROBIN RUST - - ' \ \\' �\ \ \,, \ , VENDOR: NASSIMI SYMPHONY COLLECTION ' FAB-2 FAB-2 FAB-2 FAB-2 FAB-2 FAB-2 FAB-2 FAMILY DINING FAB-2 FAB-2 FAB-2 FAB-2 \ \` \' `\\ \' \\' \\\ FAB-3 --� LJJ L———,J 105 \\ ,�' r \ \ \ `\\ \`\\ � \``\ (EXCLUDING GATHOERING AREAS AND BOOTH SEATS W amu. 0 \\\ \ \\`\ Q < ', v vv Q v :: �?.; �. '\ v", vv --- v v v O r y\ vV �y �v vv\\v VENDOR: NASSIMI SYMPHONY COLLECTION - —__�--- "� 07r=�, r2�1r2� r,2�r7r�� \` \ ` FAB-4 FABRIC: VINTAGE-OLD BRONZE ____-I —— \ ` , � ! ` `` \\ \\ `\. ``` \ LOCATION: ALL BANQUETTE SEATS &SEATBACKS. BOOTH BACK AND SEATS -I vv 1-------I I I f I I \ r->^\ v v v v v v v W C� v/ v v v v v y v € y v\', � IN GATHERING AREA v *y \} \ v c \v v v I� \ v v v FAB-2 v v ` v v ` Z FAB-2 \ v y V `vv v, v € v \ V A \ �s \ ,......"+—.,"C \ W t• 4 9 FAB 4 y y�-- v 1 tr \17� --- '� / s�"":i7":'t'' ,g. ':`v'p�" r^•x',4,r•t• t r'r'�,"i�.'!^"• tti' % \, +` ",,.\ f .L r t '••H.:i;• ::ri T•S': •,;.. .�`�i t „�:.•�:5a.` �:i w ;ti t t� •� •a V 0 A A >}:.i<•> 'lr Me-`•. •t• 'M.w•'1: •.: •!i: '• %f .:y'x•r•' 'J'w� a, \ `'a \ /// �✓ �"'M. \ \ \ \ \'n., 11 j ?y •.l..• }� .y., B"f•":t �a.•.. 1rs- a> i'-:4- w A. / v \ v Y' ,::>a '. 'ti.. •w ,t.; 1 �A..t,r: r .. ,'.r ice'' •t`:..1.;w � '.,i' w 11. •>. -. >:. I > • I I \ `\ \\,\ � \ `\,\ `\ NOTE: f— Ji..r .c. y, .td+• yt wrr•! •? yt; y. :N.a. ,•:.:'i..4� :.i i,•,, •,Y ry :.I -- 1 \' \\ \\ \ \ \ \\\ \ \ 7 \ sr• •\ a` Vis` , \ L7 !'r :t r Y' \ \* _ \ O 7' ,'C `'� :•�:�:� a', �: FAB 2 FAB 2 FAB 2 FAB 2 _ wt I ——— REFER TO SUPPLEMENTAL DOCUMENTS FOR INSTALLATION GUIDEL NES AND SPE IFI ATI N ,r� \ \ \\ _____1 —— :'i': .�... ..."I .. .'t a :r:. t i`' w'w,• \ 1 ! ua..,.. ,'s',:,.,, .d:r >.r..`:_v.+:..1r s+-.- .a:� ,:..•a•_ .•`: \ _:{ �, FAB-4> ,.' .4 \\ \ \\\\ `\ \ O I \ I , , i .,; FAB-2 �_ \ I \ FABRI PECIFICATI NS , 11 , " I I: I I I i 1 3 SCALE: NONE a } PY £.j x \ �j L L J L N --- J L _. , a r M , -, ,t , ;i , ,� .k \ \ 11 ,.s1 \ .,rte ,q., _ ap \ \ \ k` \ \ _ (PROJECT SCOPE) —— \ .\ \ \ ` \ \ �\ - �\ \ i 1.XX --- \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ y t 1 (� O \, \ ^ —7 I' \ \ \ \ FAB 2..... -,- \ \\ \ \ \\\ \ \., \ ,\ \\ , , E `\ \ I ,€ I Y\ \ \\\ \\ II . .. \ \ \ \ 1 , j `\ x, .V, .,,,_.,.,.. \ \\ \ I \ \ \ \ \\ \ \ \ \ "", ,1 E' L.ff,._ \ e.., }. W 1 1 1 S 4i> ••[. I.L. \ m___,_-_,-0---.___.0 � \\\ " \\ \ ..\\ \ \. ,\\� `•\ ,",,\ `\ '\ ,\ _ \ \ \\ `\\. \ ' '9t € \\, W\:.._� { �,""7. 00::f I \ I 121:� I �_ I \. \ \ \ . I � -.• .. , ( ._ W \ . 1 . t •• . .1. „\ \ \ \ \1.\�� \\ \\ \ \., \ \\ \ IlY r :. i � .1: ..- . ,. L.L -.t .. I - ; 1 I :.. .� \ 'r, \\ \ \ \ \ 1 1 l �.....,\ w D .. t . . .:. E : \ \ \ \ - m .i 11 \\ `\ zs ! .� ...a - .L I s, t:ti• >:,f.a �..:• ja a`,{•r; [., \ . ' '\ ''\\\\\\ \ '\, \\\\\ ,-\'\ \ \\\ '\, `'\ \ \.\ \. \, \, ' ,,,ill I€k E, t FAB-2 \..., ,. . w a \ \ \ , \ \ \\ \\\ \ \\ \” ,, W , , v \ \ \ \ � \ \ \ \ \11u. 1 ` ......_._ _.v ,\ v V \ 1. lJ n,. _: �_ : ' I FAB-2 F A v v I AB-2 FAB-3 FAB-2 FAB- `� ` — t - ~�- ~,-« 3 "' v ��:'��y-�- j v y �, -;. .::. , Ayv ., . �� ,,-,w v \ v v ', , , .._ vyvv m v y vy ^+., _....-••- �'---«..^^"^a--„ ,.y x � \ A v,.\ \\,,,'• �,.,p:,.w vy�. €1 I ' j Ati `' �z, i 3 <�g � � _ . _ ar , V \ v \\\ `\ r :Y \ \ is •.. ! . . i -.wl ..L. «.`o .< :•:<-•••C '� .n. f?. .. :\ \, "Iv.. ::.x};__.."'_::i.�_':...,. \ `,\ '\,. '"\ , t, !� \ r .�..M •.. ,. 1.t. .. . `^\ ',.'.. f .... ,t :,^ : ♦ \� \. `\'A\ Y^ \ - .\^... Imo._`•.` 1 , ..1 •1}• •• ...• r.......... a.<•:'.:.. 'w , . 1 L• .: \ `''\" \ `\ '\\ \ i,\ _ ....d.... >�::::'.. \y N FAB 3 I E \ \ E', ... .. ''ce. \r t•" .....:1,,.,:..e.,. xa•. .\ , \, ''.,. ....: _.......... , : is \ t'\ , €'i`' (� \, \ \ \ \ \ \ \ i t.J _y-- ' " ,, \ g 1 ,t : CCl' `,\ .. \\.. \\. \ "j� !f \�\ ,,\\ \\..\\ \ ,...\\ \ \,.\ \\ \, \ \`\ \', \ '% 'a•' - !=::t',L":rz\�` ,^ �a,rte ,,.''mw:. rrnxax,aroma�a�:..,roarrri..vaiewauxmrrs \ ..,....,.�, .,�,.. £-"`""; € , IN^. ! \ .\ '\. \. `? :,\ 't \ \ s, \1. \ 11 is ..�,\ '. \:r.� .......:•\\,. >.,. v/ A, ✓ "o v"rm'" u"c�xrursr.ur"<",.w l \ V ., I € I :A A. € , 'v \, b\� "�`,j -"-'^ `, ---'° ( , ,� ...E ,.,,,. v \ .. `! ``v ,\ vV. '^\ 'v Tib -`- 1 \�."� r _._ _. ; , `f 1 \,.. 1 \ \. FAB-2 FAB-2 _ ,. .w.:. :\ \ = \.\\ \ \ \ - \ m ,•.. \ �� < \ \ \ „ , x `, iamr-mg€ 'a r ......... \. \ "',, \•,I. "' I it „,! \,\ \\ .,� \ _..\_t_..'. \ _ &+.ft,.:_ 'l" .. \ `\ `'»,.� :),. C 1LL/ L ,. ,i •, f .,,,..,- -..., •.• :? .' '', \ \\..`}.'.t...::.'::''.- 11:\.:-`., ..:YFr, \\ - \� "C„'Y't/Y'l, \"\ YJ„-„_ €\e t \I I ... 1 i €::.. r ... .. a µ�',• 1 } p,«... ...,.... -..... .,....,yy' �. ""'4 I.._.,....,„,,,,,,,,,,,,.,..,,,o.,,,.»m.„ .^ ^, \ { \ ...; J t \*� "i...._t. _ _ \\\., €S 'L.:''"\`V,:..:''....:,\`',.\. „ ' ' I 3 W r �. € , € ........ .a \ \ ,,, % ” �_ m_Ni;ii�ilkl VESTIBULE O i j \ \. . \ \ ; .... '*, .._ \ S ULE , , . .. .. . .. . .. .,. :.. \ , � ,. \ : \ � `, . :\ i � - '`\ _ �'-\. , ` , Q 0 LU w 101 102 € \\ , - \ \ 1 ~ ; \ \ ', , 1'\ \ �<1� '— I I _ > , FAB 2 -. . ._. ...., \ \ \ \ € , \ ` ``\' : �: �:_.:. \ €/ I.-J, _..: \ a 1kN j� , , \ \ I..[� LL / \ _ \ .'eat' .- f ' I , : i' ;\\t`,,€ \\,\ \ ,,., t `! \ \`\` ";\ \ I( i}. \� 3h ♦ •,\\\\\r,°",< .'�€ '+;:'"<' \`\` \• i \ _ _ _ \ \ � �N r r,•.- \\" � \(�\',\\ .. \ f \"\ \Y!-4s, \T, \'` \ 1 \ � \ \ \ F ,s"' { ^,.,, S, ,, tt tt " . CHAL \�\ \ \ : :I\ \ `\\\ \ I 0 + \ i P \\ Y 'i i r. `, FAB-3 ;.:.:: --'--" -----€ \ \ \ \ . I -_ a. \, y 1 I :'t. a \ N :;� I I .._..__ a' I � a . ..::. . " ;, I �.__,_..._ --,. �: ,, `. : '' �`': '\ I I,\ ,�, \ NOT,IN SCOPE OF WORK \ � H.- ': "``•,-'�`"^ "y ''1•:.f' .'a• .t // s�\` \ `...,\ , S i \ \ \\` ,r \ O h , �... .lv� I '7. • .♦ / / ; , ; Yt,. rY \\ 'S C. C r, < r A ': € � • I 1A \ h �, OR! \ .I t \ \_. �\ I f€ :::,,,,,µ^'"""".,....ms'" '< k.`''•. "......f':: . •- e : ...- _ ._,..\.k.,t, \ , \,:.'....` ,,.. ; L.., C._+.-_..`\., ,\ j _ p ...,\r \ ._ a ..,\, \ ,:.\.r O 1 . .t. r• r q _ € ..= q3 FAB 21.% :: .f ,:,:::� \ 1\1 \ \ \. -= I €,. '"`-w„",rr,+,. >i''. .�.'..7:x""7 s. \ \ \ , \I € .tl : \i,i `\ }, «..}\ N `\ .11 I" I 11 i Ill {_ :x \ .1(i ,.,. -,✓ t f FAB 4 - \ „ , v _ v " \ a o a D 301 , x ; FAB 2 / ;. \ `\ I , ,. \ \' �• 11 \ , c. q Y r. .> ..:..-:. ! GATHERING DINING p I!..*- ( \ \ r a 1 ...•, ,: . , Ir ... ,a. S, ., ••r a 104 11 I Y""""„' r \ % , },`{. ,. \ \ ='\ .1w {si ``'\ _ '\ \:x......` r `L N li , �jj \, • i , i g .'""'--,... w-..,,,,,,,,,,,,,,,,,,,,,z ,----,.-,,.,. :i .. ......t •r I - CS \ t ,.,, \ \ \ r 1,.. \ .:t.\ •t' :.1:'v d. \ y ' \ .I€ f I !. .r. rs .....,...,.._.„. E ~` E ,..I 's \ is �>\,\. ;`.;' i \ • \ , r I f r \ , s , f 1 \., Ix•' S € 4 4 , , rww� \ \ I FAB-4 -. \ \ \ \ i .: `>✓ # Lam \ , \' \ \ \ \ i \ \ (' ,_. 't_.._.. ,!, - \\ - _ ^ - .,, "C, �": y FAB-4 $ FAB-2 FAB-3 , v \ 7 I ? FAB-2 \ \. \ .._ __. \ \,\ „ \ 3' .. ' `\ `\\\` _ I \ '\ T,r u \ \ \ \.. ` s ,. \ \ i % t \ \ �\" t .:.. _ w. .:, t € _ ' I € s ..`f,.,z"-'�'•t ..` I '\ '\ \ \ `... '+ {... \I ,p. �, Y \, \, \ , ,�: € ,\ \\ ', i \,< a E. 4 qq 4 1 ( 1\l. 1€ Y, , `"Y°°"°."-'.,®" ,[.�{i..�! ♦1. ;:•;r:� }t..�:-....i �:• I 't \\ € `\ `..f,. :1 \ \\\ :...c:......... ,; \ - c StE :'2 Y ! : tl': --v ..r..;..1 [:•;<r a,••} ''.i•::. •.:> 1 i ` \' ., :' , r. _ _ \ '* t, "\ :4'„ 1 \\ 'i . ..a € € :i \ \ \, ._:�,,... .ls, ., \ \...� µk\.1 , \\. \ ''i i \'. II _ l €, . a } I , .. ...,_.—,_„_._m._..-._._.._,. "t „t l:.__.. _a \ ;\...._�, :' I ' s'`, ,a.:1 \, ..`....\.: \\ ,`\r a t { �• \ \ \ \ \ \\ 4 I \ \ I x \ \\ \' 7 \\ \. i `\ \ \' } :::' I i i \ v \ \\ \ .. - ^y ., \ < : W.•�•:•v� ...'r-ir f �y \ \ , \ '\\ 5 4.....i ! `\\^\- \\ \, j,r \ '' � �:'"w,. \\ \ \ \ \ • 11, Revisions \ \ \ \ ....... ,...: \ \ I \ 1 ,: \ \ \ \ \l FAB-4 FAB-4 FAB-4 \ ``, '\ \ i'_ T I ISSUE FOR SCOPE REVIEW \ 1 \'.I , 4 „ \ \ \ f , y _ FAB 4 ,,... • ,.. �.t ..,>; \ __.....' `\ . \; \.\. \ i� , f;� ' .•.» ;.. L:: al' ..• '. ....sem a• > .".. ,' r, .> , '....., ,.... `\ \., , .. 5.�.;.., 1 it , I. I 1. t ,. ., _ .€ t< _ \ t.. \ I ISSUE FOR LANDLORD REVIEW . j� § 1: f T. i -rt• 305/16/14 \ \ ,. .; r. , ,•.l. a - \ \, \ .... \ \ a t -�'.. ,_, X12 ,. , `\ '`' \ ' 1. \, -" ISSUE FOR PERMIT REVIEW .. Y•Y a .... w • ,1 y , / . ' 4 N )° f . ...... .}, ,. , ♦ \ € ! \ \\ "k ' % -. /22/14 , .. :�,t� _ \ - _,,.,..._-,-._,.,.,_,.„.__ .._._.-_.,.,,,_,,,_,_1I F,z •.`«r,•.`� ,..,�., r3, 1u.a. \.. ®,:�rm„rir..�...,"F.,.:xn�...,.•: .� xi, ', ''•� ,..,,,. -. .',n,. <.«:V,,."„�, rra.,,r�r..,,, ,.a.•\ \ \\ -:.�...._.. U.. \\ I 4 1. , I \ \ ^•^^^s 11 11 . +.. •..r .A' •.r.. •. w «....r n. ,. .•.r .♦.. . .M •..F t `• . .r. .••..r _p \ \ \, N € f^......., t l Za.• [ 1 S. nf... . '..'t ••.aV ! 1 . •. ..... .M .q. •\:,♦t `y~M4� j... �'\ V\ `\ ``\ \ `'`,\ \ \ \,. .• 1. €. , € ,.•.: ..,r•,. ..•... •...,. € 11 C .. ,,. \ f �.! .. '> %. [' :.:-z. .1.-,"- :.�.: , • •; �, _:. �[ �,.> . k :, _.. HALL \ \ \ \\ �' \ \`\ \ \ . .r .. Y I . r r.€ . 4,.. ti •1':•A'µ• 2'i. `\ \ \, :v .•L I. I� .•r•'. ;. .. ....;,« •••I.3..•.1•'t:. 4w: .',t3'zm. :ri :.a.:r�i ty•. t'r \ \\, \,.\ \ I , J \ ..... \\\ \`,., �I I I v v�� 106 v\ ' \ ,\ \ `� Avv v\ v ```v �4v\\\`vy�y v v vv 0 (in L 1 FAB-4 0 \ \ \ \ \ \\ \ \ \\ \\\ \\\\ M ! j k.,.,-\ s € € - - 11 1 v\\ \y�\ \ \ v' \ v\v\�'`\\\�`'`v t \;^ f ,i' - �\^v \y \v \ \ I 1 z , t �,� t L- ” 1 ". v.,\. v.. y € I v, i .�t V `v •,`V A `• t \\ ,..�. d Y I _�j ,i�iq ;, w : € \- -\\ .\\ \\ -\ 's\ € i \ \ \\\ d , ;fit'/: •� t „ a \ C \.. MEN L—"-- ,,,,. ,� 'k I\\\ \\ \ \\j \ `\ \\\ , \\\\ \ ,.' _...._......... __..._......._...._..__ __........_..._ _ BAR LOUNGE _...- ... 1 _ � 11 \ �\, \ \€ ...«.... L� \: D E \ w & JI } I € € ,",..-. ,,,,,,,..�,.._.,.� ,...»`-^"w^ "..----.' -c -'I�.".,..,,,, i I r. °.t.\`\\\` \ `.,,,\\\, \\''"+, .,� \ \a. x\ ~, \ ."S,\\ 1 ","k zJ,' a I E I � T' 'V'- l E ' \` `\ \\\ \ '.' \ � q 103 ,_,,.� :: _ _.....__.... ; \\ \ 1 x ( I I i D �•._,._,� WOMEN \� \;\.\�� ... .. \\\\' y \�\`, Gj�' �,' \ \ \ \ ,i...... � f IAm , a \ �\ "\ \ \ 1 -1-- - �\ \ \\ ___ \\\` I� �@IV .... f ____ 107 \' -• IRNA I�H1Q __ 1 _ -`-- „<...•^^f .......„,.,. ..:;_.. z.. , y:. I: .....'".`"'""� ._.. .:C`:C.:� ..... I1. \ \ a w.i 31 Na.3'653 e: a 1` a t _..-, x _. ...._.-_.:. t\ IN , L \\\ IL ....i; 7 11L,......I \, -._....1 _... - r... .. .. 10 IIZ. Mil C € lr:z-'/', ,p� \\ -- \ \ N \ . :' \\ v y \, = '” ,'` - s I I 1 ` :t I .. - _ \ Is r \ �0 p \ \ o e 4' -s ...._...._..... ......_.... ..._:.._... __. ..... .................................. ..._..-._..._........"_... .._......._..........::._._....._......_....,.....N.._........_.. __..,.......... .._.__._._....._.-_. :! 'l:-� \ , c 1 _ ,;E moi. :.: 11 ".. (;,' x , - \ _.. - _ Lr\/: i I I - \ i E _____ =--— \ I ; -^ Gt� € 3 _\;„ _ '' '' \ r� '�' ` \ ` PARED UNDER MY SUPERVISION AND THAT TO THE BEST t I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- a „� L." � \ \ \ \ \ \ \ \ '\ \ OF MY KNOWLEDGE, m �"-, -� ,"w <.:.,�,., " . ,�:,........�.,.�...,�,..� «� .,,""","..w ",.W" "" m, « ..:�.- »� m �z , " o - \ \ `'\ \ \, \ REGULATIONS AND ORDINANCES OF PORTLAND,OREGON THE SAME COMPLY WITH ALL RULES, v) "' '�, "�,""�M '� "" """ u "" " �" " «.,r •r� RELATING TO STRUCTURES AND BUILDINGS. s k s R 0 CL ARCHITECT ? y Drawn By Checked By x m Scale Date AS NOTED 05/16/14 s Job No. a C C v C 2 C9 a Sheet No. 0 FURNISHING KEY NOTES FABRIC PLAN1 4 9 SCALE: 1/4"= 1'-0" SCALE: NONE CODE DESCRIPTION P-11 P-20 P 11 P 10 P-12 P 30 P-20 P-20 P-10 P-20 P-30 "Chelsea Gray"- FAMILY DINING WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC • P-10 PAINT CUSTOM MATCH BM #HC-168 CHELSEA GRAY (USE FORMULA IN SW SOURCE) EGGSHELL FINISH. CONTACT: 303-902-7239 s , I . I : . - P 31 "Tanager Red"- BAR / LOUNGE/ACCENT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC ; 4 IfI a \ a . P-1 1 PAINT #SW 6601 TANAGER EGGSHELL FINISH CONTACT: 303-902-7239 1 i : I , I I ; I E ; } I ` I "Chelsea Gray"- LOBBY WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC , _.... : - \ \ F I I I " I 1Ill _ _._..._......_......__................._.._.. .-__._........_._.._..._........_....................._._,.............. 1111.... I .. ........_... ............ 1111................_...... ....__._.__.... .....:__..._.._....._..-..........-_...............1111... 1 - . - .. ............_............_....._._.........._............. .........._....._........ 1 1111._.. t , 1111... __.. ._ _.._ .. .. 1111 ... .. ..................._ .. :......_.._...--__.___..._...._. 1111__._......_......_.._..___....._....._...__..........W_.__.-11_1.1..1111, i ____.. __.. _.____._.........................._.._._...... ......_....._1_111__......._.._......_.._._. _ 111-11-11 _ 1.111.. .._..__1111 _..._....___..._.._.__...1111.-........__._.___....__...____..-..._..... ._....._..___..._.._..._....._..__._..__...__.__..._..._......_.....___. .._.._....... ._. 11_____11_. ! .._...... ._ :.•? �. a'^ 'r.•'v^c'•.y :,,;�-,.' . I ...__.-..__11__11_ ._ _"-' ___.__..._..._...___.._._; 1111_.rn�""u�t;��. KIa.�.L''•JC;t'+ �`�rs ED - W--- 1--'--- - - - -"---- -- ---- ----,- ---- I ! I I - 1 I I ----_I - ,,�. �.�, N• II PAINT CUSTOM MATCH BM #HC 168 CHELSEA GRAY (USE FORMULA INS SOURCE) `"1 , I 11 ;. ; E i ,<. I { ; 1 i 1 4 g' •s:+av�'�5;�y.".{T R'' k�. ,. I 1 ;r...,- i , i 1 ........ '! ,". .ti, .U,sa3 4`Lk N"",. ...K.. :: %n ,iii '5 :: f , ,"/ ., ,: ,,'ii { , , , ,. : ,/ 1 `::i:". `Z�Y.. ..,i 'y�4��' - I „!, ,%:j as M , , EGGSHELL FINISH. CONTACT: 303 902-7239 ,. ,,l ", " i. r ss X... w ;,,. „ .f ; :',J. ;; ........ ; ;,,." ;; ," 1 '','. ,JIl 'SY7 .^z.„ ...G':a,.- .x, +•.rrw G. 1 „J J I, ;,; ( v.�, H>r.,.. ,c�."Isy,.f', :,_; ,.4•^.. as '2. � . !, ( fr vF � C I Ir ..� i ;,,, ...� ,. 7 L.._.....__..._..._..._.._..._......_......,,..--_.._.'-----_....._.-. .__..........__._.................. -E Ii . •_ r s ,, - -W PROMAR 2 ZERO VOC I ----- ----- - -- --- i f __.__-._._.._______:L._......_ :- fi . _ .�. h.>:, r� ,z "Heron Plume" RESTROOM WALLS SHERWIN-WILLIAMS O 00 -, i_.__.._._____....._....._..._._.... ...._.........._.._..__..-_........_......._.._1. __...__.___..._.._._.� __..__-__-_._...I _._-- _ __.___. i , , r 1 �,,. ' -�p7_ .r;.; PCB , ..-.-.�._.,_._�..�.._.�_ ..� _- ___.._.._- __ 1111.._, �. s Y. .d'°??[� 7:. x., ... I {: 11" ? !; � �r ",.X, .-.`�,�� P-13 PAINT #SW 6070 Heron Plume SEMI-GLOSS FINISH I %% `I k,:� :,':. '{ €i '} E \�, \ 1 f'Jl ' ,.:+ L ,b: ,�t ^.kC7 .,z v'f ,._ k,,.i. .cW ,. 11 ',,,'• 1€ ,,, t ,tel i - r.K ,x -a.t3:. w t;^'v YY.�^.,.• .e O 1.1, , r'/r ;i '`:\ \ ,, �/� s a< x K -..J'., e?:.::-�" r w.-s...• 303-902-7239 I "?% .y ,:" CONTACT: ' i '.i ✓r'i'J r' { rl, i \,.`, \ J �/f !} i' ,!r"`°.+r:n },"C:"' .x ,.^.. ..,n yXw:S.:P' +;:'rXz^i ' :. ) ,; i y''' l i ;y I , ' l' € %� ;1 ;,/ ,; t. � ..,:; "'S �'.x;I. `•sa ?'.;q;,'b�'S� ,s",�,'r :............... ... 111.1_.__._...... I I .:,.............-_._......1.1_...._1....._._1_!i. ..__.............."'_...._ _..,: ;: {: i .NI , �,v ,.,i'', N Y "i x 11. GL .�[ 's ! i- 1 JS ,. +�r y;,.1,!•1:,.. 't.yxl "h k'..p 'dY�'i... gym. .............__._....__.___._...__'•--._..__._._._..____.....__7._..1_111.-_-....___..._....._.__s; 's '. i i -t ,1!1,,1:1,, .v",'h:. 'Y` k ::r<'�. 'a ,.r. ' ii . I ._.. ............ I............ .. .M... ;.:: ..� CHALKBOARD _................1..__-.._.___1111..,. ___1111_...-_-_-___...-_1111..,t_ ____... _11_1_1..__-_. -.____.__.__...-.....1 _ . __1111.._ L. SHERWIN-WILLIAMS_....__._____._.._._._ r -' a,u� k : t a:>"' 1t�-:''.y±. -:fes^ a`.;�`x .x.,..,,x;"� ,r',i�.c�r"°r"`� '=' i,'ri. ;i :jf I .�. :I , ! I 1 3 ...._.............._.____ y..f x'`x '.yrR4`< - 'Sy;'xr ..7++t S 't�,k'.c'4 'f - - ,fif, /� ;;;,, ; ' >�€ > Mu x 1, trx�: PAINT P 14 PAINT #SW 6400 LUCENT YELLOW SEMI GLOSS FINISH E .;I I l I I( E ,:,f E I :;:J j i a +4'�az w. .✓; ^i.'.,y rt'h )_ ."+...5t,< .y�.�; if rJ ;S O 1 1 , f "" ;%%'l 1 n XY'"' , 1 s x,:.' - I i; Jl ., i /, J! :k x: rn '; a:: c �,S'� 1x : - __..__1.111__._.. - .._._.__._.....'---._.. .. _........_._..__._..__...---- _--1111... { �._.._._......_.__'._._.------�..._.._--_... __.....__J , .! I df ; i :i ''.,;' z:...:..,`.. .F1..F...:c.S:,A.' .s,�.....'+i2.,.r _ •4+!rd... CONTACT• 303 902 7239 _, , ,/ I , r 1__1_11____..__._....._..._ __........._...._._._..._ .__......_=_.___:_ :1 € ; \ \ _ ____.___ f I 1111,_ _ _ _... ............_1_111.__._._ .._ .-. _ _ ............_ _1111.................... ___.._.____...__._.._._._.._...-____.___.__._.______..__.__............._._._._-._111_1______1111..._.._..-_ _._ ., , ,,. ._ _ 11__'11..-_._._.-._._ ........_11__11..__1111 1._......._._____._...1,1_1_1.. .___. _-_1111____ 1__11__1.._'__ .i .i i I I ' _--.-"'-.-"-.-'---.--.-.----.....__....._ ------ ____._._.__ - :'s*x%� 3,,,.,,^. �: �y ix�.M __..�. .. a :- _ _ 1 � � sE .,.,1. d ., ... ... ... ... _........_ ........._...._..._ ....___.1_1___1_1"__..___.._.....__._.� ._.._.............................._... ...L. ...._......_..........._........__......_-111, 1._....._.._..____--___..........€ ........_._....__-..._ ,..____ _.--_--............----..--- _.......__.___"'�._.__._....._ _...............___....._....._.._.__...._........_....._......._..._.._.....----......._._.._.........................._..._...___._..__..._..__-11.11_1_11_1...__ ..._. _ { ; _ ._........_..._____-_1 .,_i q.. �...,,. t 1111 ;� __..1__111_...-.._._.....___;�.___. __.__..._.._...... _..._._..__..._...__..__.� _�__ ___.__ _._ - _ _......._.._...__. __ ____--._._ _. �� ,.F x "Tncorn Black"- DINING ROOM CEILING SHERWIN-WILLIAMS LOW VOC WATERBORNE iI I I �.__. I - _ 5a - ,r�� - \ ,j I fir; ;' s„ M. n� EXISTING CHAIR RAIL, P-20 DRYFALL PAINT #SW 6258 TRICORN BLACK FLAT FINISH E! %�� ; yl, I f� � ���• �"I 10 f� 1 � 'f i ,� � r�� � h �y WAINSCOT,TO BE CONTACT: 303-902-7239 I / IN OT r I. 1 REMOVED. ma L I 4� L 1. ; ,.._._...__._....................._...._....._._..._..:..._............_.._........__....__..........................:,.. .......___1_111---1111-.._......._.._.... ...._..__....__..._.__. ... �.� *.K'~:.fie'•x..; rrvy""t�x.UK .. ::`ti ✓ I , t __1111. 1_111.._-_.__-:........_11.11.-1__111..I I._..__._._..._..__.....______......_...1__........_......._..__.____._........._....., '�'' � .. .;, .. }"'� t5'T ": . -' -. '- _ _ -__----___... �s e w, BASE TO REMAIN _______�...._.___.�_-____.____.._.....---1___1.1_1 ,_1_________1__1_1_._____-_ _ _ __...._._. _ ._...__._.. _._._.__.....----.- ._. t - - -�x •. Grizzle Gray"- PATIO CEILING SHERWIN-WILLIAMS LOW VOC WATERBORNE DRYFALL P-21 PAINT #SW 7068 GRIZZLE GRAY FLAT FINISH D-301 CONTACT: 303-902-7239 - "Chelsea Gray"- LOBBY SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC CHALK WALL P-30 PAINT CUSTOM MATCH BM # HC-168 CHELSEA (USE FORMULA IN SW SOURCE)GRAY 1 LOBBY / WAITING AREA 2 EGGSHELL FINISH. CONTACT: 303-902-7239 SCALE: 1/4"= V-0" SCALE: 1/4"= 1'-0" "Extra White"-ART WALL/SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC . P-31 PAINT #SW 7006 EXTRA WHITE SEMI-GLOSS FINISH 1-1 CONTACT: 303-902-7239 P-12 P 30 ��. (D--- P-35 "Approaching Storm"- BAR / LOUNGE SOFFITS, MURAL SOFFIT SHERWIN-WILLIAMS P-32 PROMAR 200 ZERO VOC PAINT CUSTOM MATCH ICI # 1379 APPROACHING STORM _1 W I I : (USE FORMULA IN SW SOURCE) EGGSHELL FINISH. CONTACT:303-902-7239 w ry Ii . I , I I ; i ; ; c "Heron Plume"- RESTROOM SOFFITS, CEILING Q ' I ` i I I i P-33 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC PAINT #SW 6070 HERON PLUME 0 I ' I ' I SEMI-GLOSS FINISH. CONTACT: 303-902-7239 < r'�( . { I L lJ I '^ : i I "Worldly Gray"- EXPO DINING SOFFIT, RESTROOM HALLWAY CEILING W v J E P-35 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC PAINT #SW 7043 WORLDLY GRAY � 7 I ' SEMI-GLOSS FINISH. CONTACT: 303-902-7239 L E EI i �....__, b j 1111_... ............ E . i i' EI E I W 0 1 MATERIAL LEGEND �_ s,_._�_ : a 1 q. �__ SCALE: NONE Z O/ >_ ; \\\\\\ S(48' }111". 1-1 � _ i CODE DESCRIPTION M 8 ACRYLIC DIVIDER&POST � M-1 HOST PODIUM M-9A BACK BAR MILLWORK 0- �: r I- > \ M-2 HOST CABINET M-9B BACK BAR ACRYLIC PANELS m I N N ) / El I - -- - FULL HEIGHT LOUVERS M-3 SEE DETAIL 4/A5.0. M-10 BEER/LIQUOR DISPLAY V) � � M 4 M-1 2-2 M-4 M-7 M 5 M-5 M-7 M-7 M-7 WALL HEIGHT LOUVERS C) M-4 SEE SHEET A5.0. M-1 1 STAINLESS STEEL GLASS RACK W � . M-5 SLIDING ACRYLIC DIVIDERS M-12 WAINSCOT V Uj LOBBY / WAITING AREA FAMILY DINING FAMILY DINING FAMILY DINING SEE SHEET A5.0 - 3 4 5 6 �0 w M-6 ART DIVIDER M-13 WOOD COLUMN COVER � �O SEE DETAIL 5/A5.0. L1J SCALE: 1/4"= V-0" SCALE: 1/4"= 1'-0" SCALE: 1/4"= V-0" SCALE: 1/4"= 1'-0" CO �~ U) W M_7 ACRYLIC DIVIDER&POSTS(24") M_14 TOP CAP&TRIM(ONLY) � Q(/) 7 fy LU =) 0 P-10 P-20 P-10 P-20 P 11 P 20 P 10 P-1 1 C () _ MILLWORK PACKAGE ( B .O .) � z < 7 15 Coco > ry P 31 SCALE: NONE 0 N w w z I� J 0- \ . - ON, CODE DESCRIPTION = W N Z � � L.L - D 301 ART WALL IN LOBBY SEE PLAN&ELEVATIONS FOR DIMENSIONS Q O � 1111._.___. __1111.._. _ ._......_.... .__._-_111,1.1111... _-____ _._......__....... ._ __._ ,..___._....._........._. .__._...__ 1111_ _.._----..___ O _...... ......... ............................ ., ,� _.. ......_.................................._ ....._................._........__................................_._._1111..._ _ -......._......._ _...___.....................__.........._.... _ 0 ..,_.......__.. _....._........_...__._,. 1111... °° O LL \\ \ \\ D-302 BASEBALL FLAG: 60"W x 40"H 0 j I E I g�� a 4,✓, Q w r.g i 11,zd� _..X��-�-,.: '` z,t''G't�: ``'r x x I D-303 BEER MAP TIN TACKER: 78.5"W x 42"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) J W D "btd 'moi Y ( 3vi�' fl SJ ;x X,x K S x 11.Play'y X:: a,.. CD O ^' Eu; � r 'r � D-304 YUMMM SIGN: 100.5"W x 24"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) w O v J £2 u44,° ` 1 r n > a �f" s- ✓� c k M«,}i ,�a. &s"i�'�'' .3"" { r1/ O V k IL a _ Y,,^. aY",.x J w71� t �'x.:p `s�Y .�.? E \ \ \ \ \ O LL o ; rr �� m tea' :€ �� �� �� �� �� D-305 PAC-MAN CUBES: 13"W x I VH EACH a , x - F.• w., Via, 5 *gam..:. 1111. ....rmm.._ r::-::::::::a:: :::::::::::::::::::::::::::::::::::::r::::.. : :-":_,::..._:::': ;:..:: :1::111..:::. r:a::,-::.,::::::::::: ::::;:::,..;__ :_;'. ,... - ...1111. .... ... _ _ x -'' -:,::. - - WOOD BURGER SIGN-WHISKEY RIVER: 48"W 40"H D 306A - 0 00.0 ..... D-3068 WOOD BURGER SIGN-BANZAI: 34"W x 46"H U Q- _ _ _ -� .. - x .. .....I.- _.... .... . .1.... 11 1 ...._.... .__ .11.11dd. .. 1.11 d. .... .....-_-..,11_11 _........... .... _.. 11_11...__ 11.11.. _ _ 111.1..__ 1111._.. _1.111 _ -�____ 306C WOOD BURGER SIGN ROYAL' 37"W 46'H " "" �'�' __.-__ _.."..___._ _ � _ _ _____.-,___._ _,,__,,._._ __.,_ ..__._ __._ ..._-._._,.._.._ ..-._, _ _ _ _ _ _ � __. __11.11.._._ _ __. . D-306E D-306D WOOD BURGER SIGN-CHOPHOUSE �- -a r n D-202 -309 307 0 o as r. - D-306E WOOD BURGER SIGN-BURNIN'LOVE 0, -' a FAMILY DINING FAMILY DINING BAR DINING D-306F WOOD BURGER SIGN BLEU RIBBON " 7 8 9 SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" D-307A 8 TRACK WALL ART-BURGER FOR THE PEOPLE: 55"W x 45"H •� = ti- � M D-3076 8 TRACK WALL ART-MARILYN: 55"W x 45"H o N a P 10 P 10 P 20 P-10 P-10 P-20 P 10 P-10 � N a:- D-307C 8 TRACK WALL ART-UNCLE SAM: 55"W x 45"H I a D-308 LICENSE PLATE GUITARS: 15"W x 48"H(AVERAGE SIZE) 11 J'" -1 ry P 31 P 31 D-309A VHS WALL ART: 48"W x 48"H z D-3096 VHS WALL ART: 56"W x 44"H __1_1____11_ ._ __. __ . ._..__._.._...__ _1111..._ __.,_._.._._....._.___ 1__1__1.1... _ _ _ .1111_ __.._._".-....._1.111__._.____. _....__,__.__.._._._.._-____..._. __.__,__.___._,__.___..___. ___ 1111 _ . .__._,___.___.._-___.._.....,______..........___.___._.__,__.______._.1___-_.-_ _ _111 1.._..... .1111----... ............... .. .. - x :::::::. . .. ........................................................._. __ 1-1 ...._....................__................................._....................................._ .._....__..................... _ _1111__ 1111.. ___111.1.. 1111.. .. :1111 _.�....____. __ __ __.____... _ _ __._....._._. ... "POP ART"CRAYON ART: 24"W 24"H EACH „, w .S w " r _ .. .. .. -... .. 1111 .. '... ,a... :�. r , ,., ,�l-• -,d' i, . .. f. 7: ,: .. ., .. ...t d;t a 11 .1 :....ve.. .. i ,.. 1111.. ..,a_;.. -.�. -.w _.. - .. �.. 111_1 ::. , .,.,. .. ., ..t -, ...,w...:.�.... .r ':v,...<.vr '3 j ,. r {E ":is _ i :!1 : I li = i•%r IE J .% ILI i� 11 t :: i,j' f i%i' FLYING R's is D 11 1 i 3 I I I I-T0 „ I ...._._ i Revisions -J' ,. i h77 ':1111 .. ,.. ... .. 1111....._.........1111... .._......._ _. 1111-I:11__11... ..._�... 1111 .,:, , . - ... ..1111 1__111 1111.-_...................................__...__1111., 1 ,���.._...._._..._.._............_..... .. ...__...___._....._...--_.... •-___ - ,. , - .. _............ ._ _1111. _._.................._._._......._..._.........................._ ................... _............................ . ;: E: .....__..:.........................._....._.........�l_... ..............._..... _.................._......................_..... . ........_...__...._..................._... :. _....._........._....__._....... _._............................ . .... ............. -- ......_._.._..._............_.... ..__......._._..............._...._..__.. I 1; t: - 1111.._tt .._._..._..........__......_1111.._1111_ _.......................__..............._...._. ........................_......... \ { - LEGO SCULPTURE ROYAL BURGER: 24"DIA.x 22"H O SCOPE REVIEW >, : 1111 i 1 ' 'I ,J .. £ ii i €i , / 1111 ,,,i .,". ,: ,r,,, : L [ D 312A Q ISSUE FOR �11111 "i 11 04/24/14 ❑ ❑ :: Til ❑ a ,J I II' I L E 'I > r , \ 1 - Ill R: 4" IA.x 18"H 11 LE GO SCULPTURE BURNIN LOVE SURGE 2 D D 126 LANDLORD REVIEW I f iI 3 ISSUE FOR L O { i �' O ......... ___1.111____............_. , r _ ..., 1111.. _1111.._ . _...._1111._. .._. I , f; I _...._................. ,:._............ _ .. ......,E__........_..___._.._........._...�_. ?' `,,.� __.f�_........_..�.._....... _.._._......._._.........._....._..I, _1_1.11.... ; i 1 1 1# (' t I 1 ,y% i'.f i - 05/16/14 J'f I i i ; D 312C LEGO SCULPTURE-FRIES: 13"DIA.x 18"H ISSUE FOR PERMIT REVIEW I t O „,, i i S% r1! :r1f ;, ,'% I i s 11 0 4 ,,, .: , ;, „' 7 22 1 1111.1111... .,'ll :. % / / I , .... .1111 ...111..1.... ....... ..... ............ ... ... _ 111.1. ...... .. __- ..._.._............_.,._._ _......_......... _....__,.._...._........._....__.. ..._......... _,..-... , .....f .. 1111... t .. .. _ -. .. 1111. , , ......... 1111. ,: , "...(v' ,:. � , 1111.1111. ... .. ....:..........'. .. ._11::::::::::::::::::::::11. :. ... .,.. :1:11_1. ........._1111..._._.._ ................._ W .. r e; '::::. :: 1111 .. 1111. .......... 1111.. .................. ..........1111. 1111 ... ................ .......... .. 1111.. .................... ...,.............1111.1111.. ..._._. 1111 .....................:f ... . g 1111 .................:.. .................................................. ..............:::.::"::"::::::::.::..:...:..:::.::::. z'."..:.".x..:::::.:':::::.:":'::.".: I :: 1111 ,:: . ................ ,.,, '. 1111.. i i :: 1111. .............. .. _.....................__.................................. ........................._._._.._....... ".......... ........... ......... 1111 ._ .......... ......._........ .__................_......._.__.._............._.._.._._..._....................._... .............._._................._......_._._._......................_.........._...._.._ _ _1111.....-...1111 1111. 1111..1111.. 11 + 1E \�, { ....._ _11.11 -_.. . 1111. ................1111.. ;, \\ --1111._. 111.1 .. _ 1111.. I i # I, _ i ,' ' D 313 STATUE OF LIBERTY STENCIL SEE PLAN&ELEVATIONS FOR DIMENSIONS i i "„ ;," I 1 ;, , } f ,' __11__11 / ;} .....11 ................_............. ... _ __ _1111 ..-_. _ .L.�.._.._- __ _ _ _.__._I . i ; E -............ .... .. .. _....__.._.......__............__............................._.......... _....................................._..._.__......._..._._ . ..................._ . .................._...........- '- - ........_..............................._......_................._.::::...:.::::::::::::::::::::::.::.:.:....::.....:...:::.::.:.-::::.:::::.::::::.::.:.:,.-_:..-:.::.-:.-:::: ::: :::._...::--.:....,._. 7 _...._.._.._.__..........................................._...._..................................._.......................... ...._......, _ .. _:. _ D. xx W.xx H,xx D.(8 TAP)COUNTER MOUNTED _ _ .. .. ............ ......1.111 .... .. ....... . .... _...-. _...._..-1-1.•.._ -.._..__..__...-...........__..._...____............ 1111._.-_. ...1..1.....1.1.. ................................... C. I D 314 BEER SHROUD: _. ,1111 1 i r D-315A CASSETTE TAPE WALL ART: 56"W x 57"H „ D-304 D 200 M 7 M-7 D-302 D 305 Q r' D-315B CASSETTE TAPE WALL ART: 43"W x 45"H }_ W FAMILY DINING FAMILY DINING / GALLERY D-315C CASSETTE TAPE WALL ART: 35"W x 36"H ?' ZJ f 10 11 cr D-316 NOT USED , �OD�e SCALE: 114"= 1'-0" SCALE: 1/4"= 1'-0" W D-317 JIMI HENDRIX RECORD PORTRAIT: 48"W x 48"H , 17 P-10 P-20 C7~'JOHN A.CHIPMAN ' T s D-318 RED ROBIN BLOCK LETTERING No.3653 G.C. TO INSTALL ALL SIGNAGE. a s DES PLAINES,IL 5 REFER TO SUPPLEMENTAL DOCUMENTS FOR DESIGN INTENT, j INSTALLATION GUIDELINES, BEST PRACTICES, SOURCING, SHOP 11 I DRAWINGS, CUT SHEETS, & SPECIFICATIONS. Ir, _._,..._______-- ____--____1111_ __.__-______ 1_-_11.1.._ _____--_-__....�._.� __.______..._._.... _._.._...._-.-._..-...-_-___-_ I ____......__......._.._....._.__....._....._....._......_ ........_.....---._._..........- ._._....................._..----....................... 1111......._.................. 11._..__..1......__1 _. .._....._._.__.-......_...__.._----...._........._._.__..._._._......_..___.._._,-.:::.......--_._1..11.1_.__._ T__.._. ... .. ._ 1111 ........ .-:: ............._-_..._...............__...--'--. _1.1.11__... 1__111 ................_............_..............._....__..____ _...__ 11 11........................ .. ....... ; a c r ix i x .; \\ \\ \ I \\ \\ '.',�':,��r`I z9%ISx"X- _ 1111. ; �t � tr "� " Y HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- 1 "y � ° �a PARED UNDER MY SUPERVISION AND THAT TO THE BEST -Ilk,� �' mow` OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, _ 11 - __ 11 __ .. - I" ; � s,, �� a�a� T REGULATIONS AND ORDINANCES OF PORTLAND,OREGON u I I s s Mti« u Y RELATING TO STRUCTURES AND BUILDINGS. 11 R-1 z i � � 1 6 I �, J _ p i i _t i; "�1N..3''W�1f(, -4 ruf, [r.'n4 . ] i : I I I I \\\\\\ / ) i I ARCHITECT 4 ' `vi i 1111... ... 1 .11..1..........:.. .. _..... .. ......... _ ........ ......... - ... ......._-....._._... ..... ...... ... 2 .__ .. . ._ "_... .............._......... 1.111_...... .. __ 111.__11-1-1.1__._.....1.111... .. . _...... 1111............_..... 1111_.-......_..._-____. 1-1-1.111111.................. .... iDrawn By Checked By I i a I I M i `" . Scale Date N i ...._.._..__....__._....._..---'--'__1111_...-_11_11.-..................._..__......................................_..........._..._...._..._..._.�.._ .__._._............................ :___._......_...._......--1,111- _.1111_-...._......_._-_..__.._.. _..._._.......__•____.._....._....__.....-..._...... ...__._ ._..._.-.....___..-. ............._._....... .-.,__._._....._..._..._..._._._...__...._.__...._._._.......... 2 I --- ------ .....__ -- - AS NOTED 05/16/14 u Job No. a M-5 M-5 -306A -306C m C? Sheet No. E. GATHERING DINING GATHERING DINING DECOR LEGEND 0 12 13 16 9 SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" SCALE: NONE A4n0 CODE DESCRIPTION "Chelsea Gray"- FAMILY DINING WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC • P-10 PAINT CUSTOM MATCH BM #HC-168 CHELSEA GRAY (USE FORMULA IN SW SOURCE) EGGSHELL FINISH. CONTACT: 303-902-7239 "Tanager Red"- BAR / LOUNGE/ACCENT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC r" P-11 PAINT #SW 6601 TANAGER EGGSHELL FINISH CONTACT:303-902-7239 P 35 P 35 ---- -.;---- -- _____ _ - P 35 P 35 "Chelsea Gray"- LOBBY WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC _ _ - ----..........._... —.... _.._.....- .-......_.. 11 I (- _.._ ! 1 J P-12 PAINT CUSTOM MATCH BM #HC-168 CHELSEA GRAY USE FORMULA IN SW SOURCE y `- - EGGSHELL FINISH. CONTACT: 303-902-7239 ILI "Heron Plume"- RESTROOM WALLS SHERWIN-WILLIAMS PROMAR 200 ZERO VOC A' _.._...........-.... . I PAINT #SW 6070 Heron Plume SEMI-GLOSS FINISH s N ................................. .... _...._._....._.._...._......_ _... .----._._._...._........_.._._...-......................................._: ;..............__....__._....---._-_-__---.._._......... __-. ........................ .......... .. ...... ......._..-____...._..__....._.._..._........._._...� (ED .............................. CONTACT: 303-902-7239 ELLOW SEMI MAR 00 ZERO V i LucentYellow" ATI A SHERWIN-WILLIAMS PAINT #SW 6400 LUCENT Y GLOSS FINISH- i f CONTACT: 303-902-7239 Tricorn Black"- DINING ROOM CEILING SHERWIN-WILLIAMS LOW VOC WATERBORNE ED DRYFALL PAINT#SW 6258 TRICORN BLACK FLAT FINISH CONTACT: 303-902-7239 "Grizzle Gray"- PATIO CEILING SHERWIN-WILLIAMS LOW VOC WATERBORNE DRYFALL P-21 PAINT #SW 7068 GRIZZLE GRAY FLAT FINISH CONTACT: 303-902-7239 "Chelsea Gray"- LOBBY SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC HALLHALL HALL HALL NOT USED P-30 PAINT CUSTOM MATCH BM # HC-168 CHELSEA (USE FORMULA IN SW SOURCE)GRAY 1 / 18 I / 20 21 EGGSHELL FINISH. CONTACT: 303-902-7239 SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" SCALE: 1/4"= V-0" SCALE: 1/4"= V-0" "Extra White"-ART WALL/SOFFIT SHERWIN-WILLIAMS PROMAR 200 ZERO VOC P-31 PAINT #SW 7006 EXTRA WHITE SEMI-GLOSS FINISH CONTACT: 303-902-7239 P-20 P-11 P-11 P 20 "Approaching Storm"- BAR / LOUNGE SOFFITS, MURAL SOFFIT SHERWIN-WILLIAMS P-32 PROMAR 200 ZERO VOC PAINT CUSTOM MATCH ICI # 1379 APPROACHING STORM J W (USE FORMULA IN SW SOURCE) EGGSHELL FINISH. CONTACT: 303-902-7239 W 6:� "Heron Plume"- RESTROOM SOFFITS, CEILING 0 Q P-33 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC PAINT #SW 6070 HERON PLUME O SEMI-GLOSS FINISH. CONTACT: 303-902-7239 "Worldly Gray"- EXPO DINING SOFFIT, RESTROOM HALLWAY CEILING W V) - - PAINT #SW 7043 WORLDLY GRAY _._........__..... _.._.._ ....._...._..._..-_.................. O P 35 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC P ry Z ............ ................................................................. ........_ ; SEMI-GLOSS FINISH. CONTACT: 303-902-7239 w O U) ---- MATERIAL LEGEND 7 � � SCALE: NONE O z Q ALL 26ILLLLL XX ZZLIZZz i Q i = Z L------------ ---J CODE DESCRIPTION M-8 ACRYLIC DIVIDER&POSTS(48") O Cn .... .._ - - ...................... 71 ................ .. .... ..... ..... ................................*.. D 314 M-1 HOST PODIUM M-9A BACK BAR MILLWORK ) r' M-2 HOST CABINET (M-9B BACK BAR ACRYLIC PANELS N N FULL HEIGHT LOUVERS r __ M-3 M-10 BEER/LIQUOR DISPLAY SEE DETAIL 4/A5.0. V o M-11 D-303 3068M_4 WALL HEIGHT LOUVERS M-11 STAINLESS STEEL GLASS RACK � — SEE SHEET A5.0. Uj W M-5 SLIDING ACRYLIC DIVIDERS M-12 WAINSCOT V W 2 BAR / LOUNGE NOT USED SEESIVIDER .0 22 23 °� W M-6 ART DIVIDER M-13 WOOD COLUMN COVER �O W SEE DETAIL 5/A5.0. L1J SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" m ri.,~ M_7 ACRYLIC DIVIDER&POSTS(24") M-14 TOP CAP&TRIM(ONLY) < ) Z W w � p ry Q 28 MILLWORK PACKAGE ( B .O . ) z < \ SCALE: NONE � O N / OCDN W W Z r-, J n — o� CODE DESCRIPTION == �Wn/ D-301 ART WALL IN LOBBY: SEE PLAN&ELEVATIONS FOR DIMENSIONS — j O ry O 0 LL D-302 BASEBALL FLAG: 60"W x 40"H O > z — � � Q 0111-0 W D-303 BEER MAP TIN TACKER: 78.5"W x 42"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) J W 0U (D f- D-304 YUMMM SIGN: 100.5"W x 24"H (SEE ELEC.FOR LIGHTING REQUIREMENTS) � f U)O O Z C/!IL ^ D-305 PAC-MAN CUBES: 13"W x l l"H EACH D-306A WOOD BURGER SIGN-WHISKEY RIVER: 48"W x 40"H • anaw D-3068 WOOD BURGER SIGN BANZAI: 34"W x 46"H D-306C WOOD BURGER SIGN-ROYAL: 37W x 46"H - 10 D-306D WOOD BURGER SIGN-CHOPHOUSE - D-306E WOOD BURGER SIGN-BURNIN'LOVE U - 24 NOT USED D-306F WOOD BURGER SIGN-BLEU RIBBON CL SCALE: D-307A 8 TRACK WALL ART-BURGER FOR THE PEOPLE: 55"W x 45"H = D-3078 8 TRACK WALL ART MARILYN: 55"W x 45"H V L Gl -307C 8 TRACK WALL ART-UNCLE SAM: 55"W x 45"H " D-308 LICENSE PLATE GUITARS: 15"W x 48"H(AVERAGE SIZE) rs D-309A VHS WALL ART: 48"W x 48"H r, D-3096 VHS WALL ART: 56"W x 44"H D-310 "POP ART"CRAYON ART: 24"W x 24"H EACH D-311 FLYING R's Revisions T D-312A LEGO SCULPTURE-ROYAL BURGER: 24"DIA.x 22"H ISSUE FOR SCOPE REVIEW A04/24/14 D-3128 LEGO SCULPTURE-BURNIN'LOVE BURGER: 24"DIA.x 18"H ISSUE FOR LANDLORD REVIEW 05/16/14 zAD-312C LEGO SCULPTURE-FRIES: 13"DIA.x 18"H ISSUE FOR PERMIT REVIEW 07/22/14 LU D-312D LEGO SCULPTURE-SHAKE: 15"DIA.x 30"H+5"STRAW A D-313 STATUE OF LIBERTY STENCIL: SEE PLAN&ELEVATIONS FOR DIMENSIONS 0 D-314 BEER SHROUD: xx"W.xx"H.xx"D.(8-TAP)COUNTER MOUNTED Q D-315A CASSETTE TAPE WALL ART: 56"W x 57"H Q >" D-3158 CASSETTE TAPE WALL ART: 43"W x 45"H NOT USED D-315C CASSETTE TAPE WALL ART: 35"W x 36"H W 25 SCALE: D-316 NOT USED oj�D Ake D-317 JIMI HENDRIX RECORD PORTRAIT: 48"W x 48"H N D-318 RED ROBIN BLOCK LETTERING �~JOHN A.CHIPMAN XO No.3653 G.C. TO INSTALL ALL SIGNAGE. ® DES PLAINES,IL ' s REFER TO SUPPLEMENTAL DOCUMENTS FOR DESIGN INTENT, INSTALLATION GUIDELINES, BEST PRACTICES, SOURCING, SHOP DRAWINGS, CUT SHEETS, & SPECIFICATIONS. I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- PARED UNDER MY SUPERVISION AND THAT TO THE BEST a OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, REGULATIONS AND ORDINANCES OF PORTLAND,OREGON c RELATING TO STRUCTURES AND BUILDINGS. c: ARCHITECT O N Drawn By Checked By a 5 Scale Date V AS NOTED 05/16/14 Job No. a` c z Sheet No. NOT USED DECOR LEGEND 26 29A401 SCALE: 1/4"= 1'-0" SCALE: NONE s PENETRATE THREADED ROD AT EVERY O UNISTRUT SECURE 112"ALL-THREAD W/NUT&LOCK WASHER - — —— ——— —— ——— ———— ——— — — — — — — — - EXISTING ROOF DECK C D PENETRATE THREADED ROD AT EVERY UNISTRUT P1001 @ 48"O.C. UNISTRUT SECURE 1/2"ALL-THREAD UNISTRUT P1326 ANGLE CONNECTOR ,£ A EX.ROOF DECK WI 112"0 BOLTS W/PLATE WASHER INTO P1001 &(2) 112"0 THRU-BOLTS INTO 2X EX.ROOF DECK UNISTRUT P1843 PENETRATE THREADED ROD AT EVERY EXISTING ROOF TRUSS SIMPSON(2)A33 OPP.SIDE UNISTRUT SECURE 1/2"ALL-THREAD I UNISTRUT P1326 ANGLE CONNECTOR W/NUT&LOCK WASHER (2)2x4 SLEEPERS BETWEEN 6 W/1/2"0 BOLTS W/PLATE WASHER INTO UNISTRUT P1001 @48"O.C. 6 TRUSS PANEL POINTS(TYP.) A5.0 P1001 &(2) 112"0 THRU-BOLTS INTO 2X A5.0 IV' � Ll SIMPSON(2)A33 OPP.SIDE a UNISTRUT P1001 @ 48"O.C. UNISTRUT P1326 ANGLE CONNECTOR 112"DIA.THREADED RODS @ 48"o.c. WI 1/2"0 BOLTS INTO P1001 &(2) 1/2" �/ s EX.ROOF TRUSS 0 THRU-BOLTS INTO 2X "---EX.ROOF TRUSS 2X LOAD TRANSFER BLOCK BETWEEN UNISTRUT P1000 @ 48"OIC — CHORDS 2X LOAD TRANSFER BLOCK BETWEEN CHORDS 1/2"0 THREADED RODS @ 48"O.C. ( / I J W WOOD TRIM NAILED TO HEADER& 112"DIA.THREADED RODS @ 48"O.C. W UNISTRUT P1000 DIAG.BRACE @ 48"O.C.- BLOCKING. FINISH TO MATCH DOOR ALTERNATE. TACK WELD TO HANGER RODS CONT.UNISTRUT P1000 AT TOP 60OS162 O FRAME - (3)2x10 HEADER 6"METAL FRAMING 600S162-33 @ 16"O.0 W/ 0 BI HEADER ATOTOIP NUOOF 600SUS N62TMTL.RUT FRAMING 1000 SOUND BATT INSULATION. FASTEN WITH(2)#12 uj (n RE:INTERIOR SELF DRILLING SCREWS TO CONT.P-1000 7 ELEVATIONS 1/2" GYPSUM.BD.OVER 1/4"PLYWOOD LL SHEATHING (TYP.) TP. I z BIGALLERY SOFFIT B/GALLERY SOF r O 3 PER REFLECTED PER REFLECTED , CEILING PLAN CEILING PLAN 60OS162-33 @ 16"O.C.W/2412 — LU aCONT.60OT125-33 TRACK SELF-DRILLING SCREWS TO CONT.P1000Lu A 0 oCONTINUOUS 60OT125-33 LEDGER { W/2410 EACH STUD ry Q d- FIXED WOOD DIVIDERS W/ � J r TINTED ACRYLIC-B.O. w 6" REFER TO CEILING PLAN 6" SUSPENDED TRACK LIGHT HEADS TO LIGHT 6" REFER TO CEILING PLAN -SEE INTERIOR W MAX. 6'-� MAX. 6'-� pp UNDERSIDE OF SOFFIT I ARTWORK& (V ELEVATIONS FOR SIZES Cf) TABLES BELOW N I vJ^ WOOD TRIM WHEN VERTICAL ART WALL IS USED: J \ SHEATHIING�(TYP.) PROVIDE OVER 114"PLYWOOD T/WALL EXISTING.(1F NIISH EDGES OF DRYWALL W/ // / O RE:INTERIOR J-MOLD,TAPE,AND SANDING.APPLY NEW f- ,`j /(wI�� W ELEVATIONS 6"METAL FRAMING 60OS162-33 PAINT FINISH PER INTERIOR ELEVATIONS. { \.J W EXISTING LOW WALL TO REMAIN ': I Qu/ 0 W @ 16"O.0 W/SOUND BATT INSULATION :;; �/ FASTEN WITH(2)#12 SELF-DRILLING T/EXIST.CHAIR RAIL 0!�O \ FIXED ACRYLIC DIVIDER / _ 3/4" / SCREWS TO CONT.P-1000 " �~ W 1 QV W CO W =)C�� Z f_ EXISTING TOP CAP / V) Z 2 RED OAK BOTTOM RAIL I // 0 N L.L (D C14 Lij LLJ = O, a' zQ0 � m3 , 0 O DINING AREA SLIDING ACRYLIC DIVIDER DETAIL - SEISMIC M-5 FAMILY DINING GALLERY SOFFIT DETAIL - SEISMIC BAR GALLERY SOFFIT & TYP. VERTICAL ART WALL DETAIL - SEISMIC � z � W 1 2 3 � V) Q J SCALE: 1"=1'-0" SCALE: 1"=1'-0" SCALE: 1"=1'-0" Q W CD W 00 Z () NOTE: UNISTRUT P1000 cy_ [L -'— G.C.TO CONFIRM THAT REFER TO SUPPLEMENTAL EXIST.SOFFIT IS BRACED #10 SELF-DRILLING SCREW,TYP. DOCUMENTS FOR INSTALLATION TO EXISTING DECK(V.I.F.) GUIDELINES AND SPECIFICATIONS. EXISTING ROOF TRUSS ' EXISTING SOFFIT FRAMING FIN.CLG. SIMPSON(2)A33 +9'-6"A.F,F EXISTING SOFFIT UNISTRUT P1326, EACH SIDE UNITSTRUT P1000 VER TRUSS BOTT. (ONE AT EACH TOP CHORD MEMBER) BRACING(V.I.F.) I WI 112"0 THRU BOLTS CHORD SPAN BETW N 2 MIN. �� EXISTING COL.TO ( ) EACH SIDE ANGLE CONN. REMAIN. PROTECT I I - UNISTRUT ANGLE CON . ACH S E HSS 2x2xl/8"STEEL POST DURING DEMO I I UNISTRUT P1000 OVER B 1 EXIST.SOFFIT/TRUSS SOFFIT FRAMING 01 VARIES VARIES(V.I.F.) ^a REFER TO FLOOR PLAN& EXIST.TRUSS BOTT. i •� y �` SPAN BETWEEN 2 MIN. U) UNI RUT P1001 MILLWORK DWGS w CHORD WITHIN EXPO Of VARIES I I Q I I SOFFIT(V.I.F.) REFER TO FLOOR PLAN& DECORATIVE COLUMN i it , . F] F1MILLWORK DWGS PLATE WASHER I I (ll ENCLOSURE TO BE V y BOTTOM OF SOFFIT TOP OF MILLWORK � REMOVED i i Y , C/) ( I VARIES(V.I.F.) VARIES-SEE INTERIOR ELEVATIONS AND MILLWORK UNISTRUT P1326 ANGLE CO ECTOR s > EXIST.SOFFIT OR W/1/2"0 BOLTS INTO P1001 & ) 1/2"0 I I; 2:1DRAWINGS 4 T/ENOL. TOP OF MILLWORK SHIMS AT ALL SIDES THRU-BOLTS INTO 2X I I' ROOF FRAMING(V.I.F.) VARIES-SEE INTERIOR ot I, ELEVATIONS AND I I 4'-0"A.F.F. MILLWORK DRAWINGS I 2X LOAD TRANSFER BLOCK ' E I ( I I TOE NAIL TO TOP&BOTT.CHORDSEXISTING TO SHIMS AT ' ALL SIDES I I I I CD REMAIN.PROTECT DURING DEMO WOOD TRIM AT ALL SIDES E I I I I L I I I I TO MATCH LOUVER FINISH o I Revisions I Y I I F.F.E. o I I HSS 2x2x1/8"STEEL POST 0'-0" ISSUE FOR SCOPE REVIEW AT EACH END OF EXPO 04/24/14 1 ( I DIVIDER PANEL.SPACING ISSUE FOR LANDLORD REVIEW 06 VARIES.COORDINATE WITH 05/16/14 U) 07/22/ EXPO DIVIDER PANEL I I I I MILLWORK DRAWINGS OR PERMIT REVIEW ~ I 14 ui w ` HSS 2x2x1/8"STEEL POST 6 SEISMIC DETAIL 7 FLAIRED COLUMN DETAIL K o Lu I AT EACH END OF EXPO - - DIVIDER PANEL.SPACING SCALE: 1"-1 0 SCALE: 1/2" 11_011- Q 2x2x1/8"STEEL POST O VARIES.COORDINATE WITH IN MILLWORK POST { MILLWORK DRAWINGS Lu Q z E I I I I 5x5x3/8"STL.PLATE BOLTED I I I I I 0WI 318"0 x4WALL FRAME LAG 7 - 1S- ry � SHIMS AT ALL SIDES SCREWS(4 TOTAL) u o0 J 5x5x3/8"STL.PLATE o BOLTED TO WALL FRAME TOP OF EXISTING WALL OL x w 2x2xl/8"STEEL POST I I I I WI 318"0 x 4"LAG VARIES-REFER TO I 1X TREATED WOOD C,7 30HN.A.CHIPMAN ILLSCREWS(4 TOTAL) BLOCKING No.3653 AT EACH END INTERIOR ELEVATIONS I y EXIST.CONTINUOUS ' • DES PLAINES,IL (2)2X TOP PLATE(V.I.F.) } I I I I L EXISTING 6"MTL. LINE OF BASE EXISTING BELOW zo STUD WALL(V.I.F.) STRUCT COL. G LW I a I I I ( I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- - O Of 5/8"GYP.BD.TAPED, PARED UNDER MY SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, Z SANDED AND PAINTED REGULATIONS AND ORDINANCES OF PORTLAND,OREGON n I I I IRELATING TO STRUCTURES AND BUILDINGS. U O PER INTERIOR F- ELEVATIONS 6x6x1/2"STL.PLATE 6x6xl/2"STL.PLATE LL 7 FASTENED TO EXIST. I I I I FASTENED TO EXIST. W f I ARCHITECT CONC.SLAB W/ CONC.SLAB W/ (4)112"0 HILTI ANCHORS I I I ( III o (4)112"0 HILTI ANCHORS Drawn By Checked By SHIMS AT ALL SIDES I I I ( I T.CONC.SLABEXIST.CONC.SLAB EXIS Ie Scale Date AS NOTED 05/16/14 EXISTING FINISH FLOOR FINISH FLOOR Job No. U 0'-0" 0. 0., I ki w Sheet No. FULL HEIGHT LOUVER DETAIL - SEISMIC M-3 ART DIVIDER ON LOW WALL DETAIL - SEISMIC M-s NOT USED COLUMN ENCLOSURE DETAIL } 8 9A500 SCALE: 1"=1'0" SCALE: 1"=1'-0" SCALE: 1/2"=1'0" SCALE: 1 112"=1'-0" _. ............._______ _._...._.. __ -_. - _-._. ___ II. _ _:IL _1_1—; llL:I.:L—_1'11..LLlllil.._ .1'..._....".1 LIW.LL—lLIILL-L.L.LL llW.. — 1...laILI41L... '..1... :lll ...;1 ____ ______ I___ . L_.1W1!1-1...-. ! ;Ipll�:-WL:9.l{l _1.L ___.._.. . _ I:1 �l WIIIH:IIWI :WL.IW.l.W.WllIL4L1119__..II111LWlill- _.�1.- I: !� _ _ _ _ ` —_all-LL... '1-_I.__._._._ _. 4..ilILW1:_W_ _.. .. -. _ _... _._. ____.._-_-_ —__ _-_ _ -__ __ _ _ _ IL 11 9. 11. _.. lYlluWl.1LLIII.I .llllWllllYllIIIII�l911LL1NNllllllllL! 11�..L_ _Lll .111..L.Jil GENERAL ELECTRICAL NOTES EXISTING CONDITIONS & DEMOLITION GENERAL NOTES - A. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS CEILING DESIGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND it ,_ LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL ADJUST FO SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE PLENUM RETURN CEILINGS. COORDINATE PLENUM CEILING LOCATIONS OWNER. 1 WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE B. THE CONTRACTOR SHALL VISIT THE PROJECT SITE REVIEW EXISTIN --. - --_---,------------- --- --.------._.__.._ -_____-_ __---_---- --_._-.- --_ - ._. ___ -_--__- _____ __-___- -_ __.-----.__._-. --- -..___--__ __ ---_ _ - _- _-.-.__ _ _._.___ _ _----_- __.-__-._____ _--------- - --..._...._ __ -.._ _ ---__. ____-_ ___-__ .____.-___----.- CONDITIONS AGAINST THE CONTRACT DOCUMENTS, AND FAMILIARIZE1 ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED O HIMSELF WITH E 0 0 ` ....,.,,......I.........I....._,.,,,..,.,.,.,.,.,.,.,.,,.,,.,,,�,.,,,..,.__,. _,.,.,...,........,,_..........._...,.,.,................................ - -- -- _. •'• - _ "'•• "• _ - B. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN WORK. BY SIGNING THE CONTRACT, THE CONTRACTOR ACKNOWLEDGES i - -- - - ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH-IN. THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING I�, I, _ _ _________ ___ _ CONDITIONS ARE ACCEPTED. C. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY C. IT IS NOTED THAT NOT ALL ITEMS REQUIRED TO BE DEMOLISHED AR // \\\\ ;' OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO \ �r ROUGH-IN. THIS INCLUDES, BUT IS NOT LIMITED T0, MECHANICAL FIELD VERIFY AND FIELD DETERMINE THE SCOPE OF THE DEMOLITIOIll � I I I E� I 11111 EQUIPMENT, KITCHEN EQUIPMENT, AUDIO/VISUAL EQUIPMENT, FIRE WORK PRIOR TO BID. REFER ALL QUESTIONS TO THE A/E PRIOR TO \ \ �, --- SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM EQUIPMENT, ETC. BID FOR CLARIFICATION. ` `` _ - THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE THE - -- - i4�:� -- -I f U� 1' ` ,�� - CONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE \ � 5 1 LA-1 �' __ I 0 r it L �' CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, _ _.,...._»» _,. --__ __.__._.__-_ - 'ii _, CORD AND PLUG FOR ANY CORD-AND-PLUG CONNECTED EQUIPMENT THAT ____ _ - - - - - -- 1. ALL WORK SHALL CONFORM WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES AND ORDINANCES. WHERE MINIMUM CODE REQUIREMENTS ARE EXCEEDED BY THE REQUIREMENTS INDICATED IN THE SPECIFICATIONS AND ON THESE DRAWINGS, THE DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE. (IN THE CASE OF CODE CONFLICT DIRECTION SHALL BE TAKEN FROM THE MORE STRICT OF THE CONFLICTING CODES). 2. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND ALL OTHER FACTORS WHICH MAY O AFFECT THE EXECUTION OF THE WORK. INCLUDE ALL RELATED COSTS IN THE INITIAL BID PROPOSAL. LIGHT FIXTURE SCHEDULE �® 3. CONCEAL ALL ELECTRICAL WIRING AND RACEWAYS WHERE CONSTRUCTION PERMITS. EXPOSED HORIZONTAL RACEWAY RUNS ON ROOF IN EXCESS OF 5 FEET ARE NOT WAY IS PERMITTED WHERE STRUCTURE IS EXPOSED PERMITTED. EW AND INXPOSED ETHESE LOCATIONS CAREFULLY ELECTRICAL SYMBOL LEGEND TYPE MANUFACTURER CATALOG DESCRIPTION LAMPS MOUNTING VOLTS WATTS INSTALL RACEWAYS PARALLEL TO WALLS, BEAMS, AND COLUMNS. (1) SORAA 4. ALL ELECTRICAL EQUIPMENT, CONDUIT, AND LIGHTING FIXTURES SHALL BE SYMBOL DESCRIPTION SYMBOL DESCRIPTION LT-526-B LFOA LITON (1) SOR0-603-120-927-2 TRACK 120 10 ANCHORED OR SUPPORTED IN ACCORDANCE WITH THE LOCAL SEISMIC WALL MOUNTED SINGLE RECEPTACLE ELECTRIC METER REQUIREMENTS. g LFOB LITON LT-526-8 Fl-0-1 (1) SORAA TRACK 120 10 5. VERIFY THE LOCATIONS OF ALL RECEPTACLES, LUMINAIRES, EQUIPMENT MR16-50-BO3-120-927-2 CONNECTIONS, CONDUIT STUB-UPS, SIGNS, ETC. PRIOR TO ROUGH-IN. SEE WALL MOUNTED DUPLEX RECEPTACLE ® SWITCHBOARD OR DISTRIBUTION PANELBOARD LT-526-B LONG CORD 1) SORAA THE ARCHITECTURAL AND KITCHEN DRAWINGS FOR ADDITIONAL INFORMATION. LFOC LITON MR1 6-50-803-120-927-60 TRACK 120 10 6. INSTALL GREEN EQUIPMENT GROUND WIRE IN ALL POWER AND BRANCH ZQ WALL MOUNTED QUADRUPLEX RECEPTACLE Q LIGHTING AND APPLIANCE PANELBOARD LF6 ELITE BHVR6INC-12/ 6101-CL-WH (1) 70PARHIR+3KF25P1 RECESSED 120 90 CIRCUIT RACEWAYS (SEE SPECIFICATIONS). 7. ALL CONDUIT & OTHER ELECTRICAL EQUIPMENT MUST BE SUPPORTED FROM WALL MOUNTED DEDICATED DUPLEX RECEPTACLE MOTOR THE STRUCTURE ABOVE. ABSOLUTELY NO EQUIPMENT MAY BE SUPPORTED FROM THE CEILING. ANY OPENINGS CUT INTO THE ACOUSTICAL CEILING TILES SWITCHED NTED DUPLEX RECEPTACLE, ONE RECEPTACLE L.� DISCONNECT (SAFETY) SWITCH. SEE PLAN FOR RATING. LF7 HALO H99TAT/945 (1) ACCULAMP ALEBR40 RECESSED 120 50 SHALL BE CUT TO THE EXACT SIZE REQUIRED IN ORDER TO MAINTAIN ANY MATERIAL RATINGS. 8. ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75 DEGREES �J WALL MOUNTED JUNCTION/OUTLET BOX - C CEILING MOUNTED PHOTOCELL LF11 PROGRESS P5741-31BL (1) LED14E26BR4027K SURFACE 120 23 C CONDUCTORS CONNECTED TO TERMINAL LUGS & EQUIPMENT, U.L. LISTED ''��`` FOR A MINIMUM OF 75 DEGREES C. CONDUCTORS TERMINATED ON OJ F FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX - WALL MOUNTED TELEPHONE OUTLET LF19 LITON LH991CA-LLF-GU24 (1) LRELD402SN RECESSED 120 18 EQUIPMENT WITH A LOWER RATING (60 DEGREES C) OR NO RATING SHOWN, SHALL HAVE CONDUCTOR SIZE INCREASED TO CONFORM TO N.E.C. TABLE QC CEILING MOUNTED JUNCTION/OUTLET BOX OF FLUSH FLOOR MOUNTED TELEPHONE OUTLET 310.16 & U.L. NO. 489 REQUIREMENTS. LF20 THE PERIOD ARTS CEILING FAN #FLT-DB-52-BK-NL-NC N/A SUSPENDED 120 63 9. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE OR STRING. BRANCH CIRCUITING CONCEALED IN WALLS OR CEILING ® CEILING MOUNTED TELEPHONE OUTLET FAN COMPANY CONTROLS GLYDER MODEL DRD-DB-60 I =1 10. AT THE CONCLUSION OF THIS PROJECT, THE ELECTRICAL CONTRACTOR SHALL LF22 ECOSENSE WSH-40-120-IC-BK-11 WSH-M-LSD-10X60 WALL MOUNT 120 50 PROVIDE AN UPDATED TYPEWRITTEN DIRECTORY INSIDE EACH PANEL BOARD, , BRANCH CIRCUITING CONCEALED IN FLOOR WALL MOUNTED COMBINATION TELEPHONE/DATA OUTLET AND PANEL LABEL, PROPERLY IDENTIFYING EACH CIRCUIT USED & THE LF36 ACCULITE S413M-BZP MAX 75W, MR16 WALL 12 75 SPECIFIC LOAD SERVED. EXPOSED BRANCH CIRCUITING -© WALL MOUNTED COMPUTER OUTLET LF42 VARALUZ 9121730-20 (1) GE LED9DA19/827 TRACK 120 11. WHENEVER POSSIBLE, RACEWAYS AND CONDUITS SHALL BE INSTALLED 9 CONCEALED. HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES © FLUSH FLOOR MOUNTED COMPUTER OUTLET w LF50 TECH LIGHTING 700FJFIRFRC 12. CONTRACTOR SHALL COORDINATE INSTALLATION OF UTILITIES ABOVE THE THE NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED F J m 1) 35W XENON (INCLUDED) TRACK 12 35 CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OTHERWISE. GROUND WIRE IS REQUIRED BUT NOT COUNTED IN UJ 700FJHASPB OF HASH MARKS. © CEILING MOUNTED COMPUTER OUTLET Q 700FJHASPB OF & FUTURE CHANGES TO THE MECHANICAL, PLUMBING, & FIRE SPRINKLER O LF51 TECH LIGHTING 700FJFIRFKS m1 35W XENON INCLUDED TRACK 12 35 SYSTEMS, ETC. CONDUIT & PIPE TO BE RUN TO MAXIMIZE USE OF CEILING CONDUIT UP WALL MOUNTED TELEVISION OUTLET CK0011-FJ-SC ) ( ) SPACE FOR USE BY OTHER TRADES. ��r 0 700FJHASPB 13. PROVIDE A BLACK RECEPTACLE WITH A BLACK COVER PLATE. IN THE BAR, EXPO, (1) RRA DINING AREA, AND RESTROOMS. PROVIDE A GRAY OR WHITE RECEPTACLE WITH A �-�� CONDUIT DOWN ® CEILING MOUNTED TELEVISION OUTLET SO LF52 TECH LIGHTING 700MOSS604C TRACK 12 10 STAINLESS STEEL COVER PLATE IN KITCHEN AREAS. W C) MR16-50-601-12-927-2 m TELECOMMUNICATIONS SYSTEM BACKBOARD Q/ 7 LF60 SAPPHIRE CUSTOM BOTTLE PENDANT MR16 LAMPS CEILING 120 10 LL 0 EMERGENCY CIRCUIT �S� SOUND SYSTEM RACEWAY. ONE 3/4", UNO. 1) 1 1 W SELF-BALLASTED 0- �-- LF65 TWICEBRIGHT SL12011-WH BS FL (INCLUDED) CEILING 120 11 /--T-� TELEPHONE RACEWAY. ONE 3/4", UNO. �C� CLOCK SYSTEM CIRCUIT v LF68 LITON LIGHTING LRCLD802WWF-100-R12-DIN; 1400L 30K LED INCLUDED CEILING 120 12 TELEVISION RACEWAY. ONE 3/4", LINO. INTERCOM SYSTEM RACEWAY. ONE 3/4", UNO. 0 z m INSTALLATION OF ALL LUMINAIRES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO NEC AND LOCAL CODE �F� FIRE ALARM SYSTEM CIRCUIT NURSE CALL SYSTEM RACEWAY. ONE 3/4", UNO. O REQUIREMENTS. © VERIFY EXACT MOUNTING HEIGHT, LOCATION, FINISH, AND COLOR WITH ARCHITECT PRIOR TO ROUGH-IN. ALL LUMINAIRES SHALL BE AIMED PER THE ELECTRICAL ABBREVIATIONS 0:� Q d- ARCHITECT'S REQUIREMENTS. COORDINATE A TIME TO MEET WITH THE OWNER & ARCHITECT TO AIM/ ADJUST LUMINAIRES, ALL LUMINAIRES USED FOR DECOR ARE TO BE MOUNTED AS CLOSE TO TRACK AS POSSIBLE-NO EXTENSIONS, UNLESS NOTED OTHERWISE. ® PADDLE FAN SHALL BE SUPPORTED FROM STRUCTURE ABOVE AS RECOMMENDED BY MANUFACTURER. SYMBOL DESCRIPTION SYMBOL DESCRIPTION \ ® LUMINAIRE SHALL HAVE A SELF-CONTAINED BATTERY BACK-UP RATED FOR A MINIMUM OF 90 MINUTES OF OPERATION. Wp WEATHERPROOF NF NON-FUSED m I N ® EXIT LIGHT WITH APPROPRIATE MOUNTING, NUMBER OF FACES, PANEL COLOR AND ARROW DIRECTION BASED ON EACH FIXTURES LOCATION, APPLICATION I N AND THE REQUIREMENTS OF ALL LOCAL CODES AND ORDINANCES. ® NOT USED. GFI GROUND-FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR w m PROVIDE JUNO DUAL CIRCUIT TRACK IN LENGTHS AS REQUIRED PER PLAN. TRACK IS TO BE MOUNTED LEVEL, TIGHT TO DECK. PROVIDE ALL uj Q NECESSARY LIVE END CONNECTORS, STRAIGHT CONNECTORS, FLEXIBLE CONNECTORS, JOINERS, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL GFCI GROUND-FAULT CIRCUIT INTERRUPTER UNO UNLESS NOTED OTHERWISE 0 SYSTEM. REFER TO DETAIL 5/E2.2 FOR ADDITIONAL INFORMATION. TRACK IS TO BE POWERED THROUGH CURRENT LIMITING END-FEEDS AND CIRCUIT W BREAKERS. IG ISOLATED GROUND ST SHUNT-TRIP W Z ® ALL LUMIAIRES SHALL BE FURNISHED BY VILLA LIGHTING AND INSTALLED BY ELECTRICAL CONTRACTOR. HACR (HEATING AIR CONDITIONING AND REFRIGERATION) � _x W \ ® LIGHT STRIPS IN 2', 4', 6', & 8' LENGTHS, 2.43 WATTS PER FOOT AT INPUT OF TRANSFORMER. 50' MAX. LENGTH PER TRANSFORMER. LISTED AS TR TAMPER-RESISTANT HACR RATED � W COMPLYING WITH UL 1598 & CSA C22.2 NO. 250, LUMINAIRES CATEGORY LISTING NO. E212177, SUITABLE FOR WET (OUTDOOR) LOCATIONS. REFERw~ TO MANUFACTURER'S INSTRUCTIONS FOR EXACT METHODS OF INSTALLING TRANSFORMERS AND LED STRIP LIGHTS. SEE POWER PLAN (E1.2) FOR HG HOSPITAL GRADE NL NIGHTLIGHT m �V J W TRANSFORMER RECEPTACLES. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. GFPE GROUND-FAULT PROTECTION OF EQUIPMENT EM EMERGENCY ~ ® FIXTURES SHALL INCLUDE HEX LOUVER ACCESSORY UJ ZD 0 © PROVIDE TRACK MOUNTING UNLESS NOTED OTHERWISE ON FLOOR PLAN. VERIFY LENGTH OF TRACK WITH LIGHTING LAYOUT. a CO® MONOPOINT MOUNTED PENDANTS SHALL BE MOUNTED WITH FUSION JACK CANOPY WITH 4 ROUND FLUSH' MODEL # CK0011-FJ-S, TRACK MOUNTED OCCUPANCY SENSOR SCHEDULE -5 PENDANTS SHALL BE MOUNTED WITH "FREEJACK TRACK ADAPTER" MODEL # 700FJHASPB SYMBOL OCCUPANCY SENSOR MFR./MODEL NUMBER DESCRIPTION/FUNCTION W Z © PROVIDE WITH LOW-VOLTAGE FILIX DRIVER #OT96W/24V/UNV/JBX DIGITAL DUAL TECHNOLOGY (PASSIVE INFRARED AND ULTRASONIC) � O � LIGHTING PACKAGE IS BY OTHERS. (THROUGH RED ROBIN NATIONAL ACCOUNT LIGHTING VENDOR). � CEILING-MOUNTED OCCUPANCY LEVITON #OSC-10MOW WITH #OSP20 O C- N C� W NOTE: VILLA LIGHTING IS THE NATIONAL ACCOUNT LIGHTING VENDOR FOR RED ROBIN. CONTACT IS 0 SENSOR, DUAL TECHNOLOGY POWER PACK, OR EQUAL OCCUPANCYCEILING UPANCY SENSOR TURNS LIGHTS ON AND OFF BASED ON 0z DANIEL LUDWIG PH: (800)-325-0963 EXT. 133 120V OR 277V SINGLE RELAY WALL SWITCH SENSOR = Q EMAIL ADDRESS: DLUDWIG@VILLALIGHTING.COM. S1 SENSOR - ON/OFF OCCUPANCY, MANUAL SWITCH OVERRIDES AUTOMATIC L WALL SWITCH OCCUPANCY LEVITON #ODS15-ID OR EQUAL AUTOMATICALLY TURNS ALL LIGHTS ON AND OFF BASED ON 7 Q v Q FUNCTION UNTIL NEXT AUTOMATIC EVENT 0 TRANSFORMER SCHEDULE AUTOMATICALLY TURNS PARTIAL LIGHTING ON BASED ON O D LL WALL SWITCH OCCUPANCY LEVITON #ODSOD-TD OR EQUAL OCCUPANCY AS INDICATED ON THE PLANS, MANUAL SWITCH Z / � W S2 SENSOR, DUAL RELAY TURNS REMAINING LIGHTING ON AS INDICATED ON THE PLANS, �/ Q lJ TYPE MANUFACTURER MODEL # WALL WITCH SENSOR TURNS ALL LIGHTING OFF AFTER O W DR PLEXINEON ADV10OW24V 0 CD ry W U^ RM300 TECH LIGHTING 700AT300 co W '- 3 LIGHT FIXTURE SCHEDULE AND NOTES SCALE: NONE U- o y - + 0. w w C� y Ot Z CJ AA,, O w N 0(�v~.N W ^ �Q Z , W Q � _ O �O - UJ= ♦ =4/C -#20AWG SHIELDED CABLE BELDEN #9402 UU m „MO o OS SYMBOLS LEGEND V E _ x . SCALE: NONE FiLEIIAME SCALE: NONE FILENAME Qs o a Q ® Vy - rlN br3 ' V a CURRENT LIMITING CIRCUIT AMPERAGE NUMBER n ■ Vv 4A D1-1 ELECTRICAL SYSTEM SECTION 16000 ELECTRICAL SYSTEM CONTINUED ■ 10A D1-2 THE WORK INCLUDES PROVIDING NEW MATERIALS, FIXTURES, DEVICES AND ACCESSORIES NECESSARY ALL CONDUIT AND RACEWAY SYSTEMS SHALL BE INSTALLED WITH SEPARATE GREEN EQUIPMENT 4A D1-3 FOR A COMPLETE FUNCTIONING ELECTRICAL SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH GROUND CONDUCTOR. CONDUIT SYSTEM IS NOT TO BE USED AS THE SOLE GROUNDING MEANS. 10A D1-4 LOCAL CODES OR ORDINANCES AND SUBJECT TOINSPECTION. CONDUCTORS: INSULATED SOFT ANNEALLED 98% PURE COPPER WITH COLOR CODING, BANDS Revisions 7A D1-5 COMPLY WITH ALL LAWS APPLYING TO ELECTRICAL INSTALLATIONS AND WITH THE MOST RECENT GAGE, #10 AND SMALLER TO BE SOLID, 8 AND LARGER TO BE STRANDED, MINIMUM 12 UNLESS t1 nn 4A D1-6 EDITION OF THE NATIONAL ELECTRICAL CODE, ADA, APPLICABLE SECTIONS OF OTHER NFPA, OSHA, OTHERWISE INDICATED. ALUMINUM CONDUCTOR SHALL NOT BE ALLOWED. THHN SHALL NOT BE USED ISSUE FOR SCOPE REVIEW U U 8 2A D1-7LIFE SAFETY CODES AND RECOMMENDATIONS, AND THE INTERIM AMENDMENTS IN EFFECT AT THE UNDERGROUND, AT SERVICE ENTRANCE, OUTSIDE, OR IN WET LOCATIONS. ALL INSULATION SHALL BE 04/24/14 0 TIME OF THE PROPOSAL. ALL MATERIALS USED SHALL BE NEW AND SHALL CONFORM TO THE RATED FOR 600 V AND TYPES AS FOLLOWS: ISSUE FOR LANDLORD REVIEW 1A D1-8 STANDARDS ESTABLISHED BY THE UNDERWRITERS LABORATORIES INCORPORATED. A05/16/14 DA SMP 8 (120V) DB - SMP 8 (120V) D1-9 THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE #80TON#4/oALLER: TH NTHWN OR THHOR N ISSUE FOR PERMIT REVIEW 1A D1-10 PROJECT. THE DRAWINGS FOR ELECTRICAL WORK ARE DIAGRAMMATIC, SHOWING THE LOCATION, TYPE, SERVICE ENTRANCE: USE-RHW 07/22/14 2A D1-11 DEVICES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT OVER 14/0 ORDINARY SERVICE: THHN OR XHHN Q 4A D1-12 MEASUREMENTS. PROVIDE ALL FIXTURES, DEVICES, ACCESSORIES, OFFSETS, AND MATERIALS OVER 4/0 WET OR HOT SERVICE: XHHW NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE WIRE THRU FLUORESCENT FIXTURES OR WITHIN 3' OF HEATING EQUIPMENT: THHN Q 1A D1-13 EQUIPMENT FURNISHED BY OTHERS. 2A D1-14 ELECTRICAL CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. ALLOWANCES DEVICES SHALL BE MANUFACTURED BY LEVITON "INDUSTRIAL GRADE" OR EQUAL. STANDARD DUPLEX 0 7A D11-15 - ARE TO BE INCLUDED FOR UNFORESEEN EXISTING CONDITIONS THAT MAY EFFECT THE RECEPTACLES SHALL BE GROUNDING TYPE, 20A, NEMA WD-2 STANDARD 5-20R, SIDE WIRED, 3A D1-16 CONTRACTOR'S SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE INTENT OF LEVITON #5342. LIGHT SWITCHES SHALL BE 20 AMP, 120 VOLT, LEVITON #1221-2. WHERE Q THIS DESIGN IS TO BE INCLUDED IN THIS ALLOWANCE. SWITCHES ARE GROUPED, PROVIDE SINGLE MULTI-GANG PLATES. ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING UNDERGROUND UTILITIES. ANY ITEM SPECIAL PLATES: PROVIDE STAINLESS STEEL PLATES AT ALL RECEPTACLES AND LIGHT SWITCHES MOUNT RMS8 CONTROLLER IN EXPO AREA CURRENT LIMITING PANEL DAMAGED BY THIS CONTRACTOR SHALL BE REPAIRED IMMEDIATELY AND AT NO COST TO THE INSTALLED IN THE KITCHEN, WORK AREA, STORAGE ROOMS, AND CHECK IN-OUT AREA. PANEL MODEL CLS16 OWNER. THE ELECTRICAL CONTRACTOR SHALL REVIEW MATERIALS IMMEDIATELY UPON TIME OF DELIVERY AND ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75'C CONDUCTORS CONNECTED TO IMMEDIATELY REPORT ANY DAMAGED OR MISSING PIECES. TERMINAL LUGS AND EQUIPMENT, U.L. LISTED FOR A MINIMUM 75'C. CONDUCTORS TERMINATED ON LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOME RUNS FOR MAXIMUM ECONOMY AND Stellar -mme EQUIPMENT OR DEVICES WITH A LOWER RATING (60'C) OR NO RATING SHOWN, SHALL HAVE EFFICIENCY. INCREASE WIRE SIZE IF VOLTAGE DROP EXCEEDS 3% OR 100 FEET OF LENGTH. a4014na■ CONDUCTOR SIZE INCREASED TO CONFORM TO NEC TABLE 310.16 AND U.L. NO. 489 CONCEAL WIRING SYSTEM ABOVE SUSPENDED CEILINGS OR IN WALL OR FLOOR CONSTRUCTION 0.E.B PROFF t ■ • 4 e ■ 7 ■ 1 ■ REQUIREMENTS. WHERE POSSIBLE. INSTALL CONDUITS PARALLEL TO BUILDING LINES, AND TO CLEAR ALL OPENING, .S�4' `r'pzp 0 0 0 o Gqq� CABINETS SHALL BE ONE PIECE CODE GAGE GALVANIZED STEEL WITH MOUNTING STUDS, WIRING DEPRESSIONS, PIPES, DUCTS, STRUCTURE, ETC. ti 4. 6I�E� mm GUTTERS OF AMPLE SIZE AND KNOCKOUTS FOR CONDUIT CONNECTIONS AS REQUIRED. BUS BARS r LA SHALL BE 98% CONDUCTIVE COPPER, ALUMINUM, OR COPPER-CLAD ALUMINUM. FRONTS SHALL BE INSTALL CONDUIT CONTINUOUS BETWEEN BOXES AND CABINETS WITH NO MORE THAN FOUR 90 DEGREE BENDS. SECURELY FASTEN IN PLACE WITH STRAPS, HANGERS AND STEEL SUPPORTS AS A 7 ■ ONE PIECE CODE GAGE STEEL WITH ADJUSTABLE FASTENERS. PROVIDE A PLASTIC COVERED REQUIRED. DO NOT SUPPORT CONDUIT FROM SUSPENDED CEILING GRID OR SUSPENSION WIRES.D 0 0 0 0 0. mm TYPEWRITTEN SCHEDULE IDENTIFYING ALL BRANCH CIRCUITS INSIDE EACH CABINET. RECESSED 13 . • �� CABINETS SHALL BE INSTALLED WITH A MINIMUM OF TWO 3/4" SPARE CONDUITS STUBBED UP TO REAM CONDUIT ENDS BEFORE INSTALLATION AND THOROUGHLY CLEAN BEFORE INSTALLATION. . • ACCESSIBLE CEILING SPACE. OPENINGS SHALL BE PLUGGED OR COVERED TO KEEP CONDUIT CLEAN. TERMINALS ON SWITCHES � ;, �I: lii,1 ��'rtw�v AND OUTLET SHALL NOT BE USED TO "FEED THRU" TO THE NEXT SWITCH OR OUTLET. GROUNDING SYSTEM: PERMANENTLY AND EFFECTIVELY GROUND ALL METALLIC CONDUIT, SUPPORTS, ADJUSTING AND TESTING: ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR TECHNICAL DIMMING SYSTEM CONTROL DETAIL GENERAL NOTES: CABINETS, PANELBOARDS AND SYSTEM NEUTRAL CONDUCTORS. MAINTAIN CONTINUITY OF EQUIPMENT PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE FROM SHORT CIRCUITS. GROUND THROUGHOUT THE SYSTEM. GROUND CLAMPS SHALL BE APPROVED TYPE, SPECIFICALLY TT�����7 �T RMS 8 CONTROLLER DESIGNED FOR GROUNDING. WHERE GROUNDING CONDUCTOR IS ENCLOSED IN CONDUIT, GROUND TOUCH-UP OR REFINISH DAMAGED SURFACES OF FIXTURES AND EQUIPMENT EXPOSED TO VIEW. MFERENCE ONLY 1 . INFORMATION SHOWN ON THIS DETAIL IS DIAGRAMMATIC ONLY. VERIFY EXACT PART/MODEL CLAMP SHALL BE OF A TYPE WHICH GROUNDS BOTH CONDUCTOR AND CONDUIT. ALL CIRCUITS IN REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LUMINAIRES AND DATE:07/22/14 PROVIDED WITH HINGED LOCK BOX FLEXIBLE METAL OR PLASTIC CONDUIT SHALL INCLUDE A GROUND WIRE SIZED IN ACCORDANCE WITH OTHER CEILING MOUNTED EQUIPMENT. NOT APPROVED WITH THIS PERMIT IHEREBYCERTIFYTHATTHESEPLANSHAVEBEENPRE- NUMBER OF EACH COMPONENT AND ALL NECESSARY MATERIALS, AS REQUIRED FOR AN NATIONAL ELECTRICAL CODE. PARED UNDER MY SUPERVISION AND THAT TO THE BEST FOR EQUIPMENT FURNISHED BY OWNER OR OTHER CONTRACTORS; ELECTRICAL CONTRACTOR SHALL OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, OPERABLE MARLIN CONTROLS DIMMING SYSTEM, WITH MARLIN CONTROLS PRIOR TO BID, CONDUIT SHALL BE SIZED TO COMPLY WITH NEC FOR NUMBER AND SIZE OF CONDUCTORS VERIFY EXACT LOAD, TYPE OF CONNECTION AND MOUNTING HEIGHT FOR EACH BOX OR EQUIPMENT REGULATIONS AND ORDINANCES OF PORTLAND,OREGON CONTACT tech@marlincontrols.com OR 1 (800) 788-5750 FOR TECHNICAL SUPPORT. VOLUNTARY INSTALLED. PROVIDE ELECTRICAL METAL TUBING (EMT) MEETING FS W-0563, OR FLEXIBLE METAL ITEM TO BE INSTALLED. ALL HARD-WIRED CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH RELATING TO STRUCTURES AND BUILDINGS. CONDUIT (IN LENGTHS 6' OR LESS) FOR INTERIOR LOCATIONS. EMT CONNECTORS AND COUPLING FLEXIBLE LIQUID TIGHT METAL CONDUIT WITH GREEN EQUIPMENT GROUNDING CONDUCTOR INSTALLED PRODUCT SUBSTITUTIONS CANNOT BE MADE WITHOUT PRIOR APPROVAL BY THE LIGHTING AND SHALL BE SET-SCREW TYPE. CLAMP CONDUIT TO BOXES WITH BUSHING INSIDE AND LOCKNUT INSIDE RACEWAY. EQUIPMENT GROUNDING CONDUCTOR SHALL BE BONDED AT BOTH ENDS. CONTROL EQUIPMENT SPECIFIER. OUTSIDE. ("MC" & "AC" TYPE CABLES MAY BE USED IN NON- EXPOSED AREAS, EXCEPT IN THE ARCHITECT BAR, EXPO, AND COOKLINE AREAS. "MC" & "AC" CABLE MAY ONLY BE USED WHERE ALLOWED BY 2. OPERATING VOLTAGE: 120 VAC, FEED-THROUGH ONLY STATE AND LOCAL CODES). Drawn By Checked By 3. RUN A SEPARATE NEUTRAL PER CIRCUIT INTO THE DIMMER CABINET. TLH GRS 4. LOW-VOLTAGE WIRING: REQUIRES 4-CONDUCTORS, 20 AWG, BELDEN #9402 SHIELDED CABLE. Scale Date 5. FLUORESCENT BALLASTS: COMPATIBLE WITH ADVANCED MARK X DIMMABLE BALLAST. NONE 05/16/14 Job No. Sheet No. DIMMING AND CURRENT LIMITING DETAIL ELECTRICAL SPECIFICATIONS E2 . 1 4 5 SCALE: NONE I SCALE: NONE • NEW DIMMING PANEL ' D 1 ) EXISTING PANEL "LA" SCHEDULE N.E.C. LOAD ANALYSIS FOR EXISTING PANEL "LA" (INCLUDING SUBFEEDS) FED FROM: CIRCUIT BREAKER MOUNTING: FLUSH MOUNTED DEMAND PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) MAIN LUGS ONLY VOLTAGE: 120/208V, 3 PHASE, 4 WIRE ENCLOSURE: NEMA 1 LOAD DESCRIPTION FACTOR CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND 10,000 AIC BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING LIGHTING: 125% 2622 3278 3570 4463 3827 4784 10019 12524 # DESCRIPTION TYPE ZONE CIRCUIT BUS LOAD: 145 AMPS AIC RATING: MATCH EXISTING RECEPTACLE: 100% 720 720 3180 3180 180 180 4080 4080 BUS RATING: 225 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR O 1 FAMILY DINING LTG (DAYLIGHT) ELV 1 LA-21 MAIN: MAIN LUG ONLY OTHER CONTINUOUS: 125% 4050 5063 0 0 1200 1500 5250 6563 2 FAMILY DINING TRACK LTG ELV 2 LA-21 LOAD (VA) LOAD (VA) KITCHEN: 100% 0 0 2400 2400 2400 2400 4800 4800 3 FAMILY DINING TRACK ART LTG ELV 3 LA-23 NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES EXISTING LOAD: 125% 2900 3625 5800 7250 5800 7250 14500 18125 12685 7 1 TIN TACKER SIGN 1200 20/1 20/1 540 TRELLIS PLUGS 2 TOTAL: 10292 14950 17293 1340 16114 38649 46092 4 FAMILY DINING LTG ELV 4 LA-23 3 DISH ROOM 1200 20/1 20/2 1200MICROWAVE 4 EQUIVALENT AMPS: 86 106 125 145 112 135 108 128 5 FAMILY ART LTG ELV 5 LA-25 5 KITCHEN LIGHTS 1083 20/1 --- 1200 ------ 6 1 PHASE BALANCE: —21% —18% 17% 137 5% 5% 6 GATHERING DINING LTG ELV 6 LA-25 7 KITCHEN LIGHTS 897 20/1 20/1 450 FRONT SOFFIT, TC 8 9 MICROWAVE 1200 20/2 20/1 1800 TV 10 7 GATHERING ART LTG ELV 7 LA-27 11 ------ 1200 --- 20/1 1200 EXTERIOR SIGNS 12 8 GATHERING DINING LTG (DAYLIGHT) ELV 8 LA-27 13 ARCADE PLUGS 180 20/1 20/1 1200 EXTERIOR SIGNS 14 9 ENTRY LOUVERS ELV 9 LA-29 15 ARCADE PLUGS 180 20/1 20/1 120 BACK BAR LIGHTS 16 17 ARCADE PLUGS 180 20/1 20/1 210 EXPO MURAL TRACK LTS 18 10 ENTRY LOUVERS (DAYLIGHT) ELV 10 LA-29 19 YUMMM SIGN 1200 20/1 20/1 240 PATIO LIGHTS 20 11 LOUNGE DINING LTG ELV 11 LA-38 21 FAMILY DINING LTG 1151 20/1 20/1 1866 RR/ EXPO LTS & EF-5 22 12 LOUNGE ART LTG ELV 12 LA-38 23 FAMILY DINING LTG 1119 20/1 20/1 285 EXIT/EMERGENCY LTS 24 25 FAMILY/GATHERING LTG 1020 20/1 SPACE ONLY 26 13 LOUNGE ART LTG (DAYLIGHT) ELV 13 LA-40 27 GATHERING DINING LTG 205 20/1 SPACE ONLY 28 14 LOUNGE DINING LTG (DAYLIGHT) ELV 14 LA-40 29 ENTRY LOUVER LTG 348 20/1V11111 SPACE ONLY 30 15 GENERAL DOWNLIGHTS ELV 15 LA-42 31 EXISTING LOAD 1200 20/1 20/1 1200 EXISTING LOAD 32 33 EXISTING LOAD 3000 40/2 30/2 2300 EXISTING LOAD 34 16 GENERAL DOWNLIGHTS (DAYLIGHT) ELV 16 LA-42 35 ------ 3000 --- --- 2300 ------ 36 37 EXISTING LOAD 500 15/3 20/1 465 LOUNGE AREA LTG 38 ELV. =ELECTRONIC DIMMING MODULE 39 ------ 500 --- 20/1 228 BAR/LOUNGE AREA LTG 40 ELV. = ELECTRONIC LOW VOLTAGE MLV = MAGNETIC LOW VOLTAGE 41 ------ 500 --- 20/1 782 GENERAL DOWNLIGHTING 42 TOTALS: 6197 7436 7430 4095 7514 5977 REFER TO 4/E2.1 FOR DIMMING PANEL DETAIL. DIMMING PANEL IS A FEED NOTES: J W THROUGH PANEL, POWER EACH CIRCUIT FROM CIRUITS SHOWN IN PANEL D1 * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE 0 ROUTE ALL CIRCUITS THROUGH CURRENT LIMITING PANEL. REFER TO 4/E2.1 O FOR MORE INFORMATION. RELOCATE EXISTING CIRCUIT D1-6 TO CIRCUIT LA-18. PROVIDE NEW CONTROLS. W 0 RELOCATE EXISTING CIRCUIT D1-10 TO CIRCUIT LA-22. PROVIDE NEW CONTROLS. Luz z RELOCATE EXISTING CIRCUIT D1-12 TO CIRCUIT LA-24. PROVIDE NEW CONTROLS. Lu 0 n rrF-n FF_ V 0 z F- V) 0 Q Q d. w m C N 0 ti V) W V W � ry oO p W � w w > m �; = W F— Q U LU ::D � � � J ~ 10:� z w SON Z OzI W zQr1o" Q C) U O 00 3Z W U � n0 oO J U) 2 LOAD SUMMARY W o o- w SCALE: NONE • o 0o •o o 0 V O P LEGEND �- •O a W W 8, 0WNERR/UTIL I TY PROVIDED N Q o w w 0 C O w w NEW WORK = o = LL CLC) ® NEW TO EXISTING CONNECT/ON o"- - 0 Z V Ovo� o U,„8O E 41 w •� N �. /I O Q N D — O ■ ■ M EXISTING MAIN DISTRIBUTION PANELBOARD "MDP", Limm, 120/208 VOLT, 3 PHASE, 4 WIRE, 800AMP BUSC) 14J GENERAL ONE LINE DIAGRAM NOTES A. ALL EXISTING FEEDER SIZES, OVERCURRENT PROTECTION DEVICES, ETC. NOTED ON THE ONE LINE DIAGRAM AND ALL EXISTING PANEL RA TINGS INDICATED ON THE PANEL SCHEDULES ARE THE MINIMUM SIZES REQUIRED. THE ELECTRICAL Revisions 200/3 CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. IF THE ISSUE FOR SCOPE REVIEW 200A EXISTING INSTALLATION DOES NOT MEET THE MINIMUM CRITERIA NOTED ON THE A04/24/14 FUSES ONE LINE DIAGRAM AND WITHIN THE PANEL SCHEDULES, THE ELECTRICAL ISSUE FOR LANDLORD REVIEW — — — CONTRACTOR SHALL MAKE ALL NECESSARY MODIFICATIONS TO BRING THE EXISTING A05/16/14 INSTALLATION INTO COMPLIANCE WITH THE MINIMUM SIZES AND/OR RATINGS ISSUE FOR PERMIT REVIEW INDICA TED THEREIN AND INCLUDE THE COST OF ANY REQUIRED MODIFICA TIONS IN 0 07/22/14 THE INITIAL BID. POST-BID ADDITIONAL COSTS RESULTING FROM AN EXISTING Q 4 - #3/O• INSTALLATION THAT DOES NOT MEET THE MINIMUM CRI TERIA INDICATED WILL NOT #6 GROUND BE PERMITTED. IF THE EXISTING INSTALLATION MEETS OR EXCEEDS THE IN 1 1/2" MINIMUM CRI TERIA INDICA TED, MODIFICA TIONS OF THE EXISTING INS TALLA TION Q CONDUIT ARE NOT REQUIRED. 0 0 EXISTING PANEL 'LA' 10""re7 E 2 r NEW PANEL 'D1� DATE:07/22/14 'HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- REFERENCE ONLY PARED UNDER SUPERVISION AND THAT TO THE BEST OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, REGULATIONS AND ORDINANCES CF PORTLAND,OREGON NEW NOT APPROVED WITH THIS PERMIT RELATING TO STRUCTURES AND BUILDINGS. CURRENT LIMITING PANEL ARCHITECT Drawn By Checked By TLH GRS Scale Date NONE 05/16/14 Job No. Sheet No. ELECTRICAL RISER DIAGRAM E2 .2 SCALE: NONE SECTION 01010 SECTION 01520 SECTION 09250 SECTION 09900 WORK COVERED BY CONTRACT DOCUMENTS SECURITY GYPSUM BOARD PAINTING G. Wood Doors (painted): ,',"',,"''yt y`" Surface Prep: Wood - Interior Sherwin Williams S-W 24 ' "eta PART I GENERAL PART I - GENERAL PART 1 - GENERAL PART I - GENERAL Prime Coat: Multi-Purpose Oil Primer x 1.1 SUMMARY Intermediate: Pro Industrial Pre-Catalyzed Water-Based Epoxy Semi-Gloss ,1, I 1.01 INTENT OF DRAWINGS AND SPECIFICATIONS 1.01 WATCHMAN SERVICE A. This Section includes the following: 1.01 SECTION INCLUDES Finish Coat: Pro Industrial Pre-Catalyzed Water-Based Epoxy Semi-Gloss 1. Interior gypsum board. A. The Contractor shall complete all Work as provided for in Contract Documents including Drawings and A. Contractor may employ and pay for watchmen, or a watchmen's service, as he deems 2. Tile backing panels. Painting all exposed exterior and interior surfaces not specifically excluded herein. H. Wood Doors (Stained Trim - Int. & Ext. Openings) s' g p Anything g p g necessary p p pay Surface Prep: Wood -Sherwin Williams Interior S-W 24 Buildin Specifications. An thin mentioned in the Building Specification and not shown on the Drawings, or necessa to protect his own interests, and he shall be responsible for and a for losses or � �y 1.2 SUBMITTALS 1, 11 shown on the Drawings and not mentioned in the Building Specifications, shall be furnished and installed as if damages to the Owners materials or other property as a result of theft, mysterious 1.02 RELATED SECTIONS Prime Coat: Multi-Purpose Oil Primer m` shown and mentioned in both. The Contractor shall furnish all materials or labor required to complete Work disappearances or intrusions b strangers. A. Product Data: For each type of product indicated. y g Intermediate: Pro Industrial Pre-Catalyzed Water-Based Epoxy Semi-Gloss ' t , shown on the Drawingsn II t i the it and called out n e Bu ding Specifications, to include labor and material 1.3 QUALITY ASSURANCE 1. Factory applied prime coats. Finish Coat: Pro Industrial Pre-Catalyzed Water-Based Epoxy Semi-Gloss p _, requirements reasonably inferable therefrom as being necessary to complete the work, whether each and 1.02 TEMPORARY CONTROLS A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and 2. Joint treatment, taping, bedding and texturing of p g, g g gypsum drywall: SECTION 09260 every single item necessary to completion is specified or detailed or not. construction identical to those tested in assembly indicated according to ASTM E t 19 by an 3. Sealants and Caulking: SECTION 07920 B. Coverage: Coverage coats noted above are minimum requirements. Contractor shall provide A. Provide barriers to prevent unauthorized entry to construction areas and to protect existing `' independent testing agency. 4. Special coatings and finishes not specified herein. additional coats as needed for complete coverage. s''"�� '� 1.02 CONTRACTOR RESPONSIBILITY FOR WORK REQUIRED facilities and adjacent properties from damage from construction operations and demolition. 5. Factory finished mechanical and electrical equipment, panel boards, piping, devices, etc., located in PART 2- PRODUCTS special purpose enclosures, rooms or spaces, such as screens, mechanical rooms, equipment rooms, C. Colors: Colors (shown on the drawings) have been selected by the Owner, who reserves the right A. The organization of the Building Specifications into Divisions, Sections and Paragraphs and the END OF SECTION 2.1 INTERIOR GYPSUM BOARD electrical rooms, telephone rooms and janitor rooms. to select colors formulated by manufacturers other than those listed hereinbefore. Paint manufacturer arrangement of the Drawings are not intended to control the Contractor in dividing the Work among A. General: Complying with ASTM C 36/C 36M or ASTM C 1396/C 1396M, as applicable to type of gypsum shall match color(s) selected and provide color match sample(s) to Owner for acceptance. Subcontractors or to establish the limits and extent of work to be performed by a particular trade. The SECTION 01700 board indicated and whichever is more stringent. Exceptions: Items listed above specifically noted "Paint" on the drawings or in other sections of these Contractor alone is responsible for the completion of the entire work as drawn and specified, complete in CONTRACT CLOSEOUT 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering p p p p specifications. D. G.C. to provide (1) one extra gallon of paint for each color. place and in functional or operating conditions. The division of the Building Specifications into sections and products that may be incorporated into the Work include, but are not limited to, the following: General: Painting-, 2.04 SCAFFOLDING, DROP CLOTHS, ETC. paragraphs is for convenience only and not for the purpose of limiting or restricting the performance of any PART I - GENERAL 1. Sitework paving and surfacing. portion of the Work to an articular trade. a. National Gypsum Company. p y p 1.01 REQUIREMENTS b. USG Corporation. 2. Concrete foundations, walls, panels, slabs, etc. A. Provide in place, move as necessary during the course of the work, and finally remove from the END OF SECTION A. All the completed operations and/or documents described in this section shall be and/or B. Type X: 3. Factory finished materials specified in the following Divisions of these specifications: premises when work is completed, or when directed, scaffolding, staging, ladders, plastic sheeting or p 1. Thickness: 5/8 inch (15.9 mm). a. WOOD AND PLASTIC other form of drop cloths, masking tapes, storage lockers for paint materials and mixing equipment as delivered to the RRGB project manager prior to acceptance of the work and final payment. 2• Long Edges: Tapered. b. MASONRY needed for proper and efficient performance of the work. SECTION 01015 C. Flexible Type: Manufactured to bend to fit radii and to be more flexible than standard regular-type c. FINISHES CONTRACTOR USE OF PREMISES 1.02 CLEANING gypsum board of same thickness. d.SPECIALTIES 4. Factory finished: 2.05 MIXES A. General: Each Contractor or subcontractor shall remove and dispose of all tools, equipment, 1. Thickness: 1/2 inch (12 mm). a. Roofing PART I - GENERAL surplus material and rubbish pertaining to his work, and cooperate in final cleaning by general 2. Long Edges: Tapered. b. Hardware A. Paint shall be ready-mixed unless otherwise accepted by the Owner, and shall be thinned or contractor. D. Ceiling Type: Manufactured to have more sag resistance than regular-type gypsum board. c. Electrical devises and cover plates reduced only in accord with manufacturer's instruction. 1.01 REQUIREMENT B. Final Cleaning: Thoroughly clean the entire project upon completion of the work, including but 1. Thickness: 5/8 inch (15.9 mm). not necessarily limited to: Power sweeping the parking lot, cleaning construction debris from 2. Long Edges: Tapered. 1.04 INTENT PART III - EXECUTION A. Contractor coordinate use of premises for construction purposes with Owner. Because of the nature adjacent exterior areas, polishing all metals, cleaning all plumbing fixtures and accessories, cleaning 2.2 TILE BACKING PANELS J W of project premises, Contractor provide Owner with complete minimum surface area requirements for his all stainless steel fixtures and equipment, removing all labels and layout marks, cleaning all windows A. Water-Resistant Gypsum Backing Board: ASTM C 630/C 630M or ASTM C 1396/C 1396M. A. Providing Owner selected finishes and colors for exposed surfaces of the work of the construction 3.01 DELIVERY W ry and his subcontractors use, including area requirements for: and mirrors, cleaning all floors, and in general, removing all evidence of the construction process, to 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering contract. Contractor shall be responsible for field painting surfaces (not excluded above) including Q leave the entire premises in clean, new operating condition. products that may be incorporated into the Work include, but are not limited to, the following: exposed factory finished mechanical and electrical equipment, piping, etc. "Exposed"shall mean visible A. Deliver materials in unopened containers bearing manufacturers' brand name or catalog number, Q 1. Storage of materials and equipment from: ground level; floors and levels of construction of this contract; and floors and levels of buildings on and name or description of material. Carefully check delivered materials against the approved PAINT O =) 2. Staging C. Equipment and Systems: The attention of the Contractor is directed to the fact that scale, metal a. National Gypsum Company. adjacent properties. SCHEDULE. 3. Employee parking shaving, oil, pipe dope and every impurity will tend to accumulate at restricted points and impede b. USG Corporation. W Cn 4. Refuse containers flow. Every precaution shall therefore be observed in the assembly of the systems to remove and 2. Core: 5/8 inch (15.9 mm), Type X. 1.05 QUALITY ASSURANCE 3.02 STORAGE 0!:� Z 5. Other required uses exclude foreign matter and upon completion of erection, a thorough cleaning program shall be B. Cementitious Backer Units: ANSI Al 18.9. observed. The cleaning operation shall be accomplished after all parts of the systems are in place 1. Available Products: Subject to compliance with requirements, products that may be incorporated A. Qualifications of Workmen: Employ skilled workmen, experienced in the use of the specific product A. Store materials in a single place designated by the Architect. Keep storage place neat and clean. W O END OF SECTION but before any are insulated or furred in. Remove all labels, dirt, paint, grease and stains from all into the Work include, but are not limited to, the following: involved. Quality workmanship is required. Damaged areas shall be corrected by cleaning, repairing or replacing. Soiled or used rags, waste and a- � exposed devises, equipment and fixtures installed under this contract. Clean and polish all a. Custom Building Products, Wonderboard. trash must be removed from building every night. Take every precaution to avoid the danger of fire. � rn pp B. Approval of Manufacturer: Materials used shall be exactly as specified in quality. No claim F- V equipment upon completion of the work to present a first class job suitable for occupancy. b. USG Corporation-, DUROCK Cement Board. by painting subcontractor to unsuitability or unavailability of any material specified, or his Temperature of storage are should be maintained between 50 F and 45 F. SECTION 01 01 8 2. Thickness: 5/8 inch (15.9 mm). unwillingness to use same, or his inability to produce quality work with same, will be entertained. O Z OWNER FURNISHED ITEMS 1.03 PROJECT DOCUMENTS 3.03 CONDITIONS ~ = A. Affidavits: Completed AIA Document G706, CONTRACTOR'S AFFIDAVIT OF PAYMENT OF DEBTS 2.3 TRIM ACCESSORIES PART I - GENERAL p C. Regulatory Agency Requirement: Conform to applicable codes for flame/fuel/smoke C� A. Interior Trim: ASTM C 1047. 9 rY g Y q pp code(s) AND CLAIMS, with all executed supporting documents listed thereon to include "Full Waiver Final Lien 1. Material: Galvanized. rating requirements for finishes. A.Apply water-base paints only when temperature of surfaces to be coated and surrounding ry Q 1.01 OWNER'S RIGHT TO INSTALL ITEMS AND/OR EQUIPMENT PURCHASED UNDER SEPARATE CONTRACTS Release" form, "Affidavit of Completion and Warranty", and AIA Document G707, CONSENT OF 2. Shapes: air temperatures are between 50 F (10 C), unless otherwise permitted by manufacturer's 0- �: T_ SURETY COMPANY TO FINAL PAYMENT. a. Cornerbead. 1.06 SUBMITTALS instructions. � N A. Owner retains the right to place and install, in coordination with Contractor's construction schedule, as b. LC-Bead: J-shaped; exposed long flange receives joint compound. Im r N END OF SECTION c. Curved-Edge Cornerbead: With notched or flexible flanges. A. Paint Schedule: As soon as possible after Contract is signed, prepare and submit to Owner B.Apply solvent-thinned paints only when temperature of surfaces to be painted and many items and/or as much equipment as he may require during the progress of the Work, before I r�_, for acceptance an itemized PAINT SCHEDULE, listing the kinds and types of paints proposed for surrounding air temperatures are between 45 F (7 C) and 95 F (35 C), unless otherwise permitted [**-- completion of the various parts of the Work. This shall not in any way evidence completion of the Work or SECTION 09111 2.4 JOINT TREATMENT MATERIALS each and every application by name of manufacturer and brand name and color number of by paint manufacturer's printed instructions. � O any portion thereof, nor shall it signify Owner's acceptance of the Work or any portion thereof. NON-LOAD-BEARING STEEL FRAMING A. General: Comply with ASTM C 475/C 475M. the paint for each application. This PAINT SCHEDULE submitted shall be similar in tentative paint W B. Joint Tape: listed contained hereinafter with no exceptions. C.Do not apply paint in snow, rain, fog or mist; or when relative humidity exceeds 85%or to r ^ w PART II - PRODUCTS PART 1 - GENERAL 1. Interior Gypsum Wallboard: Paper. V damp or wet surfaces; unless otherwise permitted by paint manufacturer's printed instructions. 3: 1.1 SUMMARY 2. Tile Backing Panels: As recommended by panel manufacturer. „ . 0IY W g g g Gypsum Wallboard: For each coat use formulation that is compatible B. Samples: Prepare and furnish in duplicate, on chips approximately 8 x 10 in size, dry i� 2.01 CATEGORIES OF ITEMS A. This Section includes non-load-bearing steel framing members for the following applications: C. Joint Compound for Interior G patible with ry 1. Interior framing systems (e.g.,supports for partition walls, framed soffits, furring, etc.). other compounds applied on previous or for successive coats. specimens of each type finish for Owner review, Whenever possible, specimens shall be on the D. Painting may be continued during inclement weather if areas and surfaces to be painted =) LL A. By Owner: Items shown or noted as"B.O." or"By Owner" on the drawings and/or in the specifications 2. Interior suspension systems e. supports for ceilings, suspended soffits, etc. . 1. Prefillin At open joints, rounded or beveled panel edges, and damaged surface areas, use same type material as that on which it is to be used. are enclosed and heated within temperature limits specified by material manufacturer during m �~ ( g•- 9 p ) g� p g g � �..�..� shall be furnished by Owner to Contractor/subcontractor for installation by Contractor/subcontractor as setting-type taping compound. application and drying periods. � Q part of the construction contract. Contractor/subcontractor shall receive, to the extent of unloading at the 1.2 SUBMITTALS 2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, PART II - PRODUCTS LU ::D A. Product Data: For each type of product indicated. use setting-type t E.Provide adequate ventilation of spaces while applying rimer and finish coats. job site as required, store and be responsible to the extent of carrying necessary insurance to cover items in g- ype taping compound. q p p � � case of theft, fire, loss, malicious damage and other miscellaneous damage. Included, but not inclusive, in 3. Fill Coat: For second coat, use drying-type, all-purpose compound. 2.01 MANUFACTURER 1.3 QUALITY ASSURANCE 4. Finish Coat: For third coat, use drying-type, all-purpose compound. F. All application of coatings shall be done under adequate illumination. � Z U) 2 this category are: A. Fire-Test-Response Characteristics: Provide materials and construction identical to those tested in assembly z �/ p Y D. Joint Compound for Tile Backing Panels: A. The drawings were prepared and this specification written on the basis of using the products � � c� 1. All loose furnishings such as booths, table tops, chairs, stools, etc. indicated according to ASTM E 1 19 by a testing and inspection agency. 1. Water-Resistant Gypsum Backing Board: Use setting-type tapin compound and setting-type, of The Sherwin Williams Company. No substitutions will be allowed. Refer to Paragraph 3.09 of 3.04 PREPARATION O � N Z W g p Yp g9p Y• Lighting Dimmer Panel. sandable topping compound. this section for ordering information. PART 2- PRODUCTS 2. Cementitious Backer Units: As recommended b backer unit manufacturer. A. Remove dirt, rust, scale, splinters, grease and oil from surfaces to be painted. Prepare Z O� Interior Decor Items. Y p• 9 p p 2.1 NON-LOAD-BEARING STEEL FRAMING, GENERAL 7 = � A. Not In Contract (NIC): Items shown or noted "(NIC)" on the drawings and/or in the specifications shall A. Framing Members, General: Comply with ASTM C 754 for conditions indicated. 2.5 AUXILIARY MATERIALS �y 2.02 KINDS OF MATERIALS surfaces prior to painting as specified by paint material manufacturer. Remove prefinished L LL hardware, electrical devices, etc. before painting. Replace such items after finishes are Q 1. Steel Sheet Components: Comply with ASTM C 645 requirements for metal, unless otherwise indicated. A. General: Provide auxiliary _materials that comply with referenced installation standards and 0 be furnished and installed by Owner under separate contract, except as described hereinafter. Included, 2. Protective Coating: ASTM A 653/A 653M, G90 (Z275). manufacturer's written recommendations. A. Do not use paint products containing lead. completely dry. No exterior or interior painting shall be done until surfaces are thoroughly dry. CO > U but not inclusive, in this category are: B. Steel Drill Screws: ASTM C 1002, unless otherwise indicated. Painting contractor is responsible for defective work from any cause, including unsuitable and O 0 � � Z03 MATERIALS improperly prepared surfaces. Lii 2.2 SUSPENSION SYSTEM COMPONENTS 1. Use screws complying with ASTM C 954 for fastening panels to steel members from 0.033 to 0.1 12 2. 0!� V) 1. All kitchen and bar equipment. This equipment shall be furnished, assembled and set in place under A. Tie Wire: ASTM A 641/A 641 M, Class 1 zinc coating, soft temper, 0.0625-inch- (1.59-mm-) diameter wire, or inch (0.84 to 2.84 mm) thick. I O separate contract, with final connection of gas, water, electricity and exhaust devices as shown on the double strand of 0.0475-inch- (1.21-mm-) diameter wire. 2. For fastening Cementitious backer units, use screws of type and size recommended by panel A. Paint List: Where any particular application is not mentioned in this list, Contractor shall figure 3.05 PAINTING Q O � � J Mechanical and Electrical drawings to be accomplished under the General Contract for Construction. B. Wire Hangers: ASTM A 641/A 641 M, Class 1 zinc coating, soft temper, 0.162-inch (4.12-mm) diameter. manufacturer. on application of manufacturer's specification for application which is consistent with types and 0 � U) W 2. Sound system (to include speaker attachment, cable & pulling cable) C. Grid Suspension System for Ceilings: ASTM C 645, direct-hung system composed of main beams and C. Thermal Insulation: As specified in Division 7 Section"Building Insulation." qualities listed herein. A. General: Apply paint in accord with manufacturer's instructions. Use techniques and LU O O IL 0- U) 3. Signs and Signage, including Painted Exterior and Interior Signs where and if shown on drawings. cross-furring members that interlock. applications best suited for type of material being applied. Spread or flow materials on 4. Televisions. 1. Available Products: Subject to compliance with requirements, products that may be incorporated into PART 3- EXECUTION Exterior Surfaces smoothly, with proper film thickness and without runs, sags, skips or other defects. Cut paint in 5. Safe in Office. the Work include, but are not limited to, the following: 3.1 APPLYING AND FINISHING PANELS, GENERAL neatly around glass and other edges. Mix, stir, blend, etc. in strict accord with manufacturer's a. Armstrong World Industries, Inc.; Drywall Grid Systems. A. Comply with ASTM C 840. A. Wood Trim instructions Specific attention is called to stirring time intervals for stains. 6. Security/Fire Alarm System, including Duct Detectors. p Y p g 7. Television Mounting Bracket. b. Chicago Metallic Corporation; Drywall Furring System. B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold Surface Prep: Wood -Sherwin Williams Exterior S-W 23 `7 C) 41, c. USG Corporation; Drywall Suspension System. damaged. ,V , 'a 8. A.D.A. Interior Door Signs. g Prime Coat: Exterior Latex Wood Primer B. Wash metal surfaces with mineral spirits to remove dirt, oil or grease before applying primer. C. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments, Intermediate: Sherwin Williams A-100 Exterior Satin Latex Remove rust or scale b wire brushing or sanding cleaning before painting. Marred shop coats t �' 9. Window Blinds. Y g g g p 9• p = ' 2.3 STEEL FRAMING FOR FRAMED ASSEMBLIES except floors. Provide 1/4-to 1/2-inch- (6.4-to 12.7-mm-) wide spaces at these locations, and trim Finish Coat: Sherwin Williams A-100 Exterior Satin Latex of paint shall be cleaned and touched u with rimer, riot to finish coats. `".. 10. Toilet compartments. A. Steel Studs and Runners: ASTM C 645. edges with edge trim where edges of panels are exposed. Seal joints between edges and abutting p p p p a) 11. Toilet accessories. _ 1. Minimum Base-Metal Thickness: 0.0312 inch (0.79 mm) As well as, as indicated on drawings. structural surfaces with acoustical sealant. 0 -- 2. - 2. Depth: As indicated on Drawings. D. Wood Framing: Install B. Ferrous & Non-Ferrous Metals C. Galvanized metal surfaces shall be given a crystalline zinc phosphate pre-treatment. Two C �., a -- PART III - EXECUTION gypsum panels over wood framing, with floating internal corner construction. Do B. Slip-Type Head Joints: Where indicated, provide the following: not attach Surface Prep: Hand Tool Cleaning Sherwin Williams S-W 14 products for this purpose are Lithoform made by American Chemical Paint Co., Ambler, Pa., a gypsum panels across the flat grain of wide-dimension lumber, including floor joists and � W headers. Float gypsum panels over these members, or provide control joints to counteract wood Prime Coat: Prolndustrial ProCryl Universal Metal Primer and Galvaprep #5, made by Neilson Chemical Co., Detroit, Michigan. W ._ •- 3.01 RECEIPT OF ITEMS 1. Deflection Track: Steel sheet top runner manufactured to prevent cracking of finishes applied to shrinkage. Intermediate: Prolndustrial Acrylic Semi-Gloss = :4 interior partition framing resulting from deflection of structure above-, in thickness not less than Finish Coat: Prolndustrial Acrylic Semi-Gloss D. Masonry surfaces shall be cleaned of any soil, efflorescence, excess mortar, etc. If wet CLI � = ,- a. A. During the course of construction, some deliveries of equipment and miscellaneous items will be made indicated for studs and in width to accommodate depth of studs. 3.2 APPLYING INTERIOR GYPSUM BOARD cleaning is used, allow adequate time for drying to allow for uniform penetration. All cracks .a , � to the job site by common carrier. Contractor shall receive and inspect items for conformance to delivery a. Available Products: Subject to compliance with requirements, products that may be incorporated A. Install interior gypsum board in the following locations: C. Glavanized shall be pointed or caulked. All voids in masonry joints shall be filled. Neutralize acid washed - into the Work include, but are not limited to, the following: "' " ticket(s) and for damage. If during receipt any missing or damaged items are observed, Contractor shall: g: Surface Prep: Galvanized Metal Sherwin Williams S-W 10 surfaces. Moisture content of surface shall not exceed 15% in order to apply sealer. Allow new 1) Dietrich Metal Framing. 1. Type X: As indicated on Drawings. Prime Coat: Prolndustrial ProCryl Universal Metal Primer surfaces to age four weeks prior to application of sealer. 1 11 1. Make notation of any and all discrepancies on the delivery ticket(s). 2) USG Corporation. 2. Flexible Type: Apply at curved assemblies. Intermediate: Prolndustrial Acrylic Semi-Gloss 2. Call delivery carrier and advise him of the problem. 3. Ceiling Type: Ceiling surfaces. Finish Coat: Prolndustrial Acrylic Semi-Gloss E. Interior trim and cabinetry shall be back-primed with wood primer. 11 3. Call the Owner's Purchasing Contact and advise of any problems. PART 3- EXECUTION 4. Moisture-and Mold-Resistant Type: As indicated on Drawings. 3.1 INSTALLATION, GENERAL D. Concrete F. Remove hardware, hardware accessories, machined surfaces, plates, lighting fixtures, and IIIIIIIIIIIIIIII A. Installation Standard: ASTM C 754, except comply with framing sizes and spacing indicated. 3.3 APPLYING TILE BACKING PANELS IIIIIIIIIIIIIIII END OF SECTION Surface Prep: Sherwin Williams Concrete S-W 5 similar items in place and not to be finish-painted, or provide surface applied protection prior to IIIIIIIIIIIIII A. Water-Resistant Gypsum Backing Board: Install at showers, tubs, and where indicated. Install with Prime Coat: Sherwin Williams Loxon Exterior Acrylic Mason Primer surface preparation and painting operations. Remove, if necessary, for completing paintingof .� 1. Gypsum Board Assemblies: Also comply with requirements in ASTM C 840 that apply to framing 1/4-inch (6.4-mm) gap where panels abut other construction or penetrations. ry Masonry p p p g p ry" p g y installation. Intermediate: Sherwin Williams A-100 Exterior Satin Latex items and adjacent surfaces. Following completion of painting of each space or area, reinstall SECTION 01029 B. Cementitious Backer Units: As indicated on drawings. Finish Coat: Sherwin Williams A-100 Exterior Satin Latex removed items. VCHANGE ORDER PROCEDURES C. Where tile backing panels abut other types of panels in same plane, shim surfaces to produce a 3.2 INSTALLING SUSPENSION SYSTEMS uniform plane across panel surfaces. r A. Isolate suspension systems from building structure where they abut or are penetrated by building structure E. Stucco G. Scratches, cracks and abrasions on surfaces to be painted shall be filled with a spackling Revisions PART I - GENERAL to prevent transfer of loading imposed by structural movement. 3.4 INSTALLING TRIM ACCESSORIES Surface Prep: Stucco Sherwin Williams S-W 22 compound flush with adjoining surface. When dry, sand smooth and seal before application of ISSUE FOR SCOPE REVIEW B. Suspend hangers from building structure as follows: A. General: For trim with back flanges intended for fasteners, attach to framing with same fasteners used Prime Coat: Sherwin Williams Loxon Exterior Acrylic Masonry Primer priming coat. 1.01 GENERAL 1. Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that for panels. Otherwise, attach trim according to manufacturer's written instructions. Intermediate: Sherwin Williams A-100 Exterior Satin Latex 0 04/24/14 ISSUE FOR LANDLORD REVIEW are not part of supporting structural or suspension system. B. Interior Trim: Install in the following locations: Finish Coat: Sherwin Williams A-100 Exterior Satin Latex H. Enamel applied to wood or metal shall be sanded with fine sandpaper and then cleaned 0 05/16/14 1. A. "General Conditions of the Contract for Construction, Article 7, all paragraphs inclusive, shall govern the a. Splay hangers only where required to miss obstructions and offset resulting horizontal forces by 1. Cornerbead: Use at outside corners, unless otherwise indicated. between coats to produce an even, smooth finish. ISSUE FOR PERMIT REVIEW work of this section. bracing, countersplaying, or other equally effective means. 2. LC-Bead: Use at exposed panel edges. F. Unit Masonry 0 07/22/14 2. where width of ducts and other construction within ceiling plenum produces hanger spacings that 3. Curved-Edge Cornerbead: Use at curved openings. Surface Prep: Block (Cinder and Concrete) Sherwin Williams S-W 3 1. Metal door frames shall be made smooth by filling and sanding before finishing. Touch-up 1.02 WORK AUTHORIZATION interfere with locations of hangers required to support standard suspension system members, install Prime Coat: Sherwin Williams PM BILK FLR factory prime coat before applying first coat. supplemental suspension members and hangers in the form of trapezes or equivalent devices. 3.5 FINISHING GYPSUM BOARD Intermediate: Sherwin Williams A-100 Exterior Satin Latex �` A. In the event a change to the work is required by the Owner, a written "Work Authorization"for changes 3. Do not attach hangers to steel roof deck. A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener 0 to the contract will be issued by the Owner. The authorization will include actual or estimated costs for the 4. Do not attach hangers to permanent metal forms. Furnish cast-in-place hanger inserts that extend heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Finish Coat: Sherwin Williams A-100 Exterior Satin Latex J. Prepare and stain interior wood siding as scheduled prior to installation. fl change and a statement of responsibility for actual cost if estimated costs are used. through forms. Promptly remove residual joint compound from adjacent surfaces. 0 5. Do not attach hangers to rolled-in hanger tabs of composite steel floor deck. B. Prefill open joints, rounded or beveled edges, and damaged surface areas. Interior Surfaces: K. Drying Time: Unless, otherwise specified, exterior paints shall dry for 48 hours and interior r 1.03 CONTRACTOR RESPONSE 6. Do not connect or suspend steel framing from ducts, pipes, or conduit. C. Apply joint tape over sum board joints, except those with trim having flanges not intended for tape. paints for 24 hours between coats. 0 pp Y J p gypsum 1 p 9 g p 7. Do not attach hangers to exhaust hoods. D. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C 840: A. Wood (painted): s, C. Seismic Bracing: Sway-brace suspension systems with hangers used for support. 1. Level 1: Ceiling plenum areas, concealed areas, and where indicated. Surface Prep: Wood - Interior Sherwin Williams S-W 24 L. Sanding: Sand enamels and varnish lightly and dust between coats. A. Contractor shall respond with a formal typewritten Contract Change Order", m triplicate, referencing D. Grid Suspension Systems: Attach perimeter wall track or angle where grid suspension systems meet vertical 2. Level 2: Panels that are substrate for tile. Prime Coat: Multi-Purpose Latex Primer -7- ZS -1 authorization number,job name, date, specific items changed and shall indicate total amount of surfaces. Mechanically join main beam and cross-furring members to each other and butt-cut to fit into 3. Level 3: At panel surfaces that will be exposed to view. Intermediate: ProMar° 200 Interior Zero VOC Latex Eg Shel M. Acceptance: If, authorization imposed costs. Contractor will only be allowed an (8%) eight percent overhead and profit wall track. E. Cementitious Backer Units: Finish according to manufacturer's written instructions. Finish Coat: ProMar® 200 Interior Zero VOC Latex Eg Shel 1. Work is subject to acceptance by the Owner and any work not complying with these markup. Backup documentation is to be submitted with all extra costs. Two or more authorizations may be E. Installation Tolerances: Install suspension systems that are level to within 1/8 inch in 12 feet (3 mm in 3.6 m) specifications shall be corrected to the satisfaction of the Owner. E3 included on one change order. measured lengthwise on each member that will receive finishes and transversely between parallel 3.6 PROTECTION B. Drywall: 2. Final coat of paint shall have visual evidence of hiding and uniform appearance. e�� �' :L members that will receive finishes. A. Protect installed products from damage from weather, condensation, direct sunlight, construction, and ,�� +41A J; p g g Surface Prep: Drywall-Sherwin Williams Interior & Exterior S-W 8 3. Paint shall be evenly spread and smoothly flowed on without runs, sags, curtains or other , END OF SECTION other causes during remainder of the construction period. Prime Coat: PrepRite° 200 Interior Zero VOC Latex Wall Primer evidence of poor application. 0 JOHN-A. 3.3 INSTALLING FRAMED ASSEMBLIES B. Remove and replace panels that are wet, moisture damaged, and mold damaged. w n A. Where studs are installed direct) against exterior mason walls or dissimilar metals at exterior walls, install Intermediate: ProMaro 200 Interior Zero VOC Latex Eg Shel 4. Spot painting will be allowed to correct soiled or damaged paint surfaces only when No.3653 ,,q y SECTION 01040 Y g masonry 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, Finish Coat: ProMar° 200 Interior Zero VOC Latex Eg Shel touch-up spot will blend into surrounding finish and is invisible to normal viewing. Otherwise, f COORDINATION isolation strip between studs and exterior wall. sagging, or irregular shape. • DES PLAINES,IL B. Install studs so flanges within framing system point in same direction. re-coat entire section to Corners or visible stopping point. 9 9 Y p 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface C. Ferrous Metals (exposed) also include ceilingdiffuser grilles): J PART I - GENERAL 1. Space studs as follows: contamination and discoloration. ( p ) ( g )' T a. As indicated on drawings. Surface Prep: Hand Tool Cleaning Sherwin Williams S-W 14 3.06 PROTECTION AND CLEANING 1.01 PROJECT COORDINATION C. Install tracks (runners) at floors and overhead supports. Extend framing full height to structural supports or END OF SECTION 09250 Prime Coat: Prolndustrial ProCryl Universal Metal Primer substrates above suspended ceilings, except where partitions are indicated to terminate at suspended Intermediate: Prolndustrial Acrylic Semi-Gloss A. Protect work, adjacent work, and materials, by suitable covering. Upon completion of work, 16; A. Contractor shall be responsible for the general overall coordination of the work required. It is the ceilings. Continue framing around ducts penetrating partitions above ceiling. Finish Coat: Prolndustrial Acrylic Semi-Gloss remove paint and varnish spots from floors, glass and other surfaces. - Contractor's responsibility to see that all of his subcontractors coordinate their work as it relates to the work of l. Slip-Type Head Joints: Where framing extends to overhead structural supports, install to produce joints other trades. at tops of framing systems that prevent axial loading of finished assemblies. D. Open Ceilings (Gypsum Board) 3.07 CLEAN-UP A. Upon completion of work of this section, remove related debris from the IHEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- 2. Door Openings: Screw vertical studs at jambs to jamb anchor clips on door frames-,install runner track Surface Pre Drywall-Interior & Exterior Sherwin Williams S-W 8 premises. PARED UNDER MY SUPERVISION AND THAT TO THE BEST Z 1.02 MECHANICAL AND ELECTRICAL COORDINATION p' ry OF MY KNOWLEDGE,THE SAME COMPLY WITH ALL RULES, M section (for cripple studs) at head and secure to jamb studs. Prime Coat: PrepRite° 200 Interior Zero VOC Latex Wall Primer REGULATIONS AND ORDINANCES OF PORTLAND,OREGON A. Contractor shall coordinate the leaving of openings in the building floors, roofs and walls for supply, return a. Install two studs at each jamb, unless otherwise indicated. 3.08 ORDERING INFORMATION RELATING TO STRUCTURES AND BUILDINGS. Intermediate: ProMar° 200 Interior Zero VOC Latex Eg Shel and exhaust ducts, piping and wiring unless otherwise noted or specified herein. It is the Contractor's b. Install cripple studs at head adjacent to each jamb stud, with a minimum 1/2-inch (12.7-mm) Finish Coat: ProMar� 200 Interior Zero VOC Latex Eg Shel .,= responsibility to see that all of his subcontractors coordinate their work with regard to openings which are to clearance from jamb stud to allow for installation of control joint in finished assembly. A. All finish coat paints can be obtained from THE SHERWIN-WILLIAMS COMPANY. be left in floors, roof and partitions for the proper operation of all systems and that all openings are in correct c. Extend jamb studs through suspended ceilings and attach to underside of overhead structure. ARCHITECT 9 E. Open Ceilings (Wood Trusses) y locations. 3. Other Framed Openings: Frame openings other than door openings the same as required for door Surface Pre Drywall-Interior Sherwin Williams S-W 24 THE SHERWIN WILLIAMS COMPANY openings, unless otherwise indicated. Install framing below sills of openings to match framing required p ry Drawn By Checked By above door heads. Prime Coat: PrepRite@ 200 Interior Zero VOC Latex Wall Primer 101 Prospect Avenue N.W. 1.03 CUTTING AND PATCHING Intermediate: ProMar° 200 Interior Zero VOC Latex E Shel Cleveland, OH 44115 4. Fire-Resistance-Rated Partitions: Install framing to comply with fire-resistance-rated assembly indicated g 216/556-2902 Scale Date 0 and support closures and to make partitions continuous from floor to underside of solid structure. Finish Coat: ProMaO 200 Interior Zero VOC Latex Eg Shel A. Except as otherwise specified, each subcontractor shall execute all cutting and patching in his work that 05/16/14 0 may be re uired b others so that the en a ements between the various material will be neat and ro er. a. Firestop Track: Where indicated, install to maintain continuity of fire-resistance-rated assembly ,G y q Y engagements proper. indicated. F. Open Ceilings / Galvanized Metal -Steel B. All orders must be placed through THE SHERWIN-WILLIAMS COMPANY either by telephone or Job No. Cutting of any structural portions of the building shall not be permitted except as approved by the Owner. 5. Curved Partitions: Surface Prep: Hand Tool Cleaning Sherwin Williams S-W 14 FAX. No pickups or deliveries will be made without THE SHERWIN-WILLIAMS COMPANY purchase Each subcontractor shall locate and provide sleeves, suitable to the general contractor, for all holes, chases, a. Bend track to uniform curve and locate straight lengths so they are tangent to arcs. Prime Coat: Sherwin Williams Pro-Cry) Universal Acrylic Primer orders or verbal authorization. Please allow 3-5 working days to process order. openings, or block-outs required for the installation of their work. All such openings shall be straight, true, and b. Begin and end each arc with a stud, and space intermediate studs equally along arcs. On straight Intermediate: Low VOC Waterborne Acrylic Dryfall, Flat B42W81 Sheet No. of proper size. No excessive cutting will be permitted, nor shall openings be located to alter the installation of lengths of not less than 2 studs at ends of arcs, place studs 6 inches (1 50 mm) o.c. Finish Coat: Low VOC Waterborne Acrylic Dryfall, Flat B42W81 END OF SECTION a any structural member from that indicated on drawings. After the work has been installed, all openings shall D. Direct Furring: be carefully patched and fitted around as directed and to the satisfaction of the Owner. 1. Screw to wood framing. if END OF SECTION END OF SECTION 09111 spi 00 G A