Plans (4) BUP2014- 00165
RECEIVEDSQUARE TOO
JUL 2 2 2014
C4TYOFTGW AT WASHINGTON SQUARE
BUICDIPI(;DI7lISit�V
Mall Address:
AT
BUILDING A BUILDING B WASQUARE TOO
„��„„ SHtNGTON SQUARE
9585 S.W. Washington Square
Portland, OR 97223
Phone: (503) 639-8865
__ _.......... .�..._......
Fax: (503) 620-5612
I � For Leasing
IA01 Information Contact:
RED ROBIN Q A05 A07 W W ' ' Alesha Shemwell
I cn COST PLUS -j u-
0-0i W AVAILABLE m CO �, m � - Christoper Looney
71460 SF ¢ Q 1'7,097 SF ,_
d 5,620 SF 1 m M m g _ BP3 — Macerich
"-- U N I j j N AVAILABLE ' 7525 166th Ave. NE, Ste. D210
24,217 SF Redmond, WA 98052
_ f Phone: (425) 869-2640
-.-.. Fax: (425) 867-1577
. . �f Peripheral Leasing Group
.. .........�.. __..._m_ _.µ .._...... ..,,_ ............ _.. L _ Big Box, Pad &
Restaurant Leasing
Brian Christifulli
M N Phone: (602) 953-6480
so
AV CO,
I LASL O
3,6s0 SF 4r
2 wOVV T�QVEo
C0 'QW
� 690
SF 2
s BARN CO3
/ BCO�S & NOBLE " M
76, 161 S FRS
F
Note:
This is a schematic plan only
1 n/ intended to show the general layout
of the shopping center or part
f ( I1 thereof. This plan is not to be scaled.
STC04
.. ARBUC1( Q ..
�.,. 2-314 ,3p S P Last Updated:
0
.,....... " V � CITY OP TIGARD
. �
REVIEWED FOR CODS COMI'LUNC>�
JAN 11 , 2013
Approve* I
co I OTCs I )I
j ..,,._ Address 02
Suite#s
Bys Dates
. BUILDING
- OFFICE COPY
SITE PLAN
NORTH
Demo the entire interior of the C04
Provide live, fully functional,
usable and separately metered space shown, including flooring down
electrical service including, but to exposed slab (including any
not limited to, adequately sized 6 , adhesive products or grout, mortar,
conduit and feeder wires from
the point of service to a location _ 3's �7 etc), all interior walls, ceiling, Wall
'~ finishes and gyp board back to
��
(TBD) within the Premises / h, exposed studs/CMU wall, all utility M AC E R I C H
which will be located on a w;, 241 lines back to the source, all plumbing
/ f "� ����. �~�-~ to under slab and patched, all roof
demising wall, not an interior k to RTUs and curbs Include roof
Wall within the Premises. �� � `° �--_
p (
Service to be 400-amp patches)
208/120V/three phase, 4-wire ............--........._................._.............................................._........._...__.____........................................._.___..__........
% 4_ WASHINGTONelectrical power to the
Premises delivered as two
% _
200A 120/208V services to one ���° SQUARE TOO
400A main circuit breaker '
panel, 42 circuit panel-board if V
(with breakers) per Tenant's ]
specifications, containing / Noodles & Company
2-15OA-3 Pole sub-feed ! SPACE : C04
breakers feeding two 225A /
� 2291.
F . �
main lug only 42 circuit S
panel-boards (With breakers) i / ' , i
DATE : 03 . 07 . 14
per Tenants specifications. All C,
' � SCAL - V= 10'
panels shall be adequately N
sized for the incoming available / Stub into Premises one 1 .5" domestic cold water
fault current. All panel-boards i line terminating in a shut-off valve in the plenum.
shall be bolt-on circuit breaker �� �' Test pressure inside Premises and provide
type and of the same j % results showing line has a minimum guaranteed
manufacturer. / C04 consistent residual pressure of 60 PSI and a
y
2291 S . F .
guaranteed consistent residual flow of 35 GPM
KEY PLAN
NORTH
If Construct new metal stud demising
LEASE / '
walls (shown in red lines)(6 20 GA,
LINE � 16"" OC from slab to deck above. ASE OUTLINE
i } DRAWING
Perform demo as needed to install
if the new wall. Patch back of finishes
or ceiling is not required.
Required doors and frames shall
/ I and installed by each tenant (any
/ doors shown in plans are suggested only;
/ final determination is by tenant). It is required
VERIFY �' Install 5/8" gyp board finished to that the tenant, contractor, architect or
COLUMNS representative must visit the site and
/ F, paint ready condition on opposite
° - side from C04 of new demising/ verify all familiarize and v dimensions and
sizes of major itemsy such as structural
walls from slab to deck and fire elements, electrical runs, plumbing locations
and items not covered by this drawing. This
Caulk leaving exposed Studs on
shall be done at Tenant's expense. When
ll
id
C04
the se of the new was.
exit passageways are present to provide a
secondary exit from a Tenant's space, doors
shall be one-hour fire doors. Such doors
42;�poc2a 6 . shall be self-closing and be so maintained or
r /
shall be automatic closing by smoke detector
' actuation. Prior to finalizing terms and
o
c+3 conditions, Leasing and Center Management
must resolve exiting per applicable codes.
The telephone conduit running from Jet clean sanitary sewer line serving i' Include in your bid any Service area, empty electrical conduit,
the demark to the Premises must _ required drawings and Cit
the Premises. Trace the line and `~
submittals to obtain the Prepared by located within the lease line. Tenant must y sewer, water, and empty telephone conduit
remain remove the were and Install mark on the slab the location that the Aaron Pratt field verify all dimensions and conditions.
a pull string. sanitary line enters the Premises. required permits. Permit fee
---- --- does not need to be Macerich Drawn by: G2 T.C.: AP
included. 3-17-14