Permit (45) CITY OF TIGARD MECHANICAL PERMIT 1,1 COMMUNITY DEVELOPMENT Permit#: MEC2016-00068 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/28/2016 , Parcel: 2S102AD03000 Jurisdiction: Tigard Site address: 12850 SW ASH AVE Project: Burnham&Ash Apartments Subdivision: BURNHAM TRACT Lot: 5 Project Description: Building 1 -Complete HVAC for 4-story apartment building Contractor: AMERICAN HEATING INC Owner: PREMIUM PROPERTY-TIGARD LLC 5035 SE 24TH AVE 1015 NW 11TH AVE., STE 243 PORTLAND, OR 97202-4765 PORTLAND, OR 97209 PHONE: 503-239-4600 PHONE: 503-226-1972 FAX: 503-239-7038 FEES Specifics: Description Date Amount Type of Use: MF Permit Fee 07/28/2016 $12,536.71 Class of Work: ALT Type of Const: VA Plan Review 07/28/2016 $3,134.18 Occupancy Grp: R-2 Occupancy Load: 12%State Surcharge-Mechanical 07/28/2016 $1,504.41 Stories: 4 Info Process/Archiving-Lg$2.00(over 07/28/2016 $10.00 11x17) Project Valuation: $440,000.00 Fuel Air Handlers Fuel Types: Natural Gas Units< 10000 cfm: 7 Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 5 50 or Greater HP: Air Conditioning: 7 Heat Pump: 24 Appliances Vent Fans: 184 Vent Systems: Total $17,185.30 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: 20 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of rules adopted bythe Oregon issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the u p 9 Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987. :.N. '- 344. --- Issued By: '-rmittee Signator • G � � Call 503.639.4175 by 7:00 a.m.for the next available inspection date This permit card shall be kept in a conspicuous place on the job site until completion of a otect_" Approved plans are required on the job site at the time of each inspection. t Mechanical Permit Applilati, ,n .�f FOR OFFICE USE ONLY City of Tigard Received I - q Date/By: ..27 / j PermitNo.: tst L.'n 7�/� � �� 13125 SW Hall Blvd.,Tigard,OR 97223 Plan RevieC �`"4 Phone: 503.718.2439 Fax: 503 5981400 ;;�', Date/By ---;.'11".4/1114.2 Other Permit ��� ��3 TIGARD Inspection Line: 503.639.4175 Date Re runs: Internet: www.tigard-or.gov Y- See Page 2 for e „ : ,. Notified Method Supplemental Information fi 1-: 1r :. T : 6 3 :CO1M TRC AI-FE* S�D LE IISEc>i CKLt§T Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$$440,000.00 i �tATEC ORY 7F QNSTRU€^ITLTN , : , ,,,: .., .:_ RESIDElYTIA ❑ 1-and 2-familydwelling �� - I7IPl4T1YT��Ti`;TEMSFEE�* ®Commercial/industrial '❑Accessory building For special information use checklist. 0 Multi-family 0 Master builder 0 Other: Description Ea. 1 Total t JQBSITEII�FORS ) TUCATION Heating/cooling: Air conditioning 46.75 Job site address:12850 SW ASH Furnace 100,000 BTU(ducts/vents) 46.75 h City/State/ZIP:Tigard OR 97234 Furnace 100,000+BTU(ducts/vents) 54.91 1 Heat pump 61.06 (9 Suite/bldg./apt.no.:bldgl 1 Project name:Burnham and Ash Apartment Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydropic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: I Other: 23.32 Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 P IPTI£IN QF' Womc r -4 fireplac 33.39 Gas lace/insert Flue vent for water heater or gas Complete Hvac System for aApts Bldg 1 fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 PIit31'IRTi OWNEIT Other: 23.32 ❑ TENANT -"�_ . . . a," sem. Environmental exhaust and ventilation: Name: Range hood/other kitchen Address: equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 _. ,�. _„ , APPLT ' T �" '7r Gp A ". -.., 1ST ti Other: 23.32 Business name:American Heating Inc. Fuel piping: �����E '' 0 $14.15 for first four;$4.03 for each additional Contact name:Brandon Hutchinson /14 7-67"_ <50 3,-e o- .5-w Furnace,etc. Address:5035 SE 24th Ave Ce—G-1- 1t' Gas heat pump Wall/suspended/unit heater City/State/ZIP:Portland,OR.,97202 Water heater Phone:(503)239-4600 Fax::(503)239-7038 Fireplace — Range E-mail:b.hutchinson@americanheating.net Barbecue l`" $4 , V4 C O j c " ,-. , .., 40 . T, �, a Clothes dryer(gas) Business name:American Heating Inc. Other Address:5035 SE 24th Ave Subtotal City/State/ZIP:Portland,OR,97202 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)239-4600 Fax:(503)239-7038 State surcharge(12%of permit fee) CCB lie.:33135 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: • • Fee methodology set by Tri-County Building Industry Service Board Print name:Brandon Hutchinson Date:/. 2) •/( I:\BuildingWermits\4EC_PermitApp_040113.doc 440-4617T(11/02/COM/SEB) 4 ' June 14, 2016 RE: Mechanical Alternate Design and Construction Methods Project Information Building Permit: MEC2016-00068 Construction Type: 5A Tenant Name: Burnham and Ash Apartments Occupancy Type: M Address: 12850 SW Ash Occupant Load: NA Area: NA Stories: 4 Oregon Structural Specialty Code(OSSC) 2014 Section 104.11 States: "The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved.An alternative material,design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code,and that the material, method or work offered is,for the purpose intended,at least the equivalent of that prescribed in this code in quality,strength,effectiveness,fire resistance, durability and safety." The Exception to Oregon Structural Specialty Code(OSSC) 2014 Section 717.6.1 States: "A duct is permitted to penetrate three floors or less without a fire damper at each floor, provided such duct meets all of the following requirements: 1. The duct shall be contained and located within the cavity of a wall and shall be constructed of steel having a minimum wall thickness of 0.0187 inches(0.4712 mm)(No. 26 gage). • The provided exhaust ductwork meets all of these duct construction requirements. 2. The duct shall open into only one dwelling or sleeping unit and the duct system shall be continuous from the unit to the exterior of the building. • Each exhaust duct opens into only 1 dwelling unit and meets all of these requirements. 3. The duct shall not exceed 4-inch (102 mm) nominal diameter and the total area of such ducts shall not exceed 100 square inches in any 100 square feet(9.3m2)of floor area. • These requirements include a concentration requirement(100 square inches in any 100 square feet)and a size requirement(4-inch nominal diameter).All of the installed exhaust ducts meet the concentration requirement.The dryer exhaust ducts are 4" round ducts and meet the size requirement.The kitchen and restroom exhaust ducts are 31/4x10" rectangular during their vertical runs.They are discussed below. 4. The annular space around the duct is protected with materials that prevent the passage of flame and hot gasses sufficient to ignite cotton waste where subjected to ASTM E 119 or UL 263 time- temperature conditions under a minimum positive pressure differential of 0.01 inch (2.49 Pa)of water at the location of the penetration for the time period equivalent to the fire-resistance rating of the construction penetrated. • The annular space is sufficiently protected by the specified materials and meets all of these requirements. 5. Grille openings in a ceiling of a fire-resistance-rated floor/ceiling or roof/ceiling assembly shall be protected with a listed ceiling radiation damper installed in accordance with Section 717.6.2.1" • The design of the applicable exhaust duct does not contain grille openings in fire- resistance-rated floor ceiling assemblies. 0 The vertical exhaust ducts used on this project meet the base requirements of this exception because they do not penetrate more than three floors.They also meet all of the requirements for provisions 1,2, 4,and 5 as listed previously. Each floor/ceiling and roof/ceiling penetration is protected with a through penetration detail (HILT!System F-C-7043)tested per UL 1479 to provide equivalent protection to a fire damper with a 1 hour F rating equivalent to the fire-resistance-rating of the construction penetrated. Provision 3 specifies a 4" nominal diameter maximum duct size.Two types of vertical ducts penetrating floor/ceiling and roof/ceiling assemblies are used on this project.4" round dryer ducts which meet both the size and concentration requirements listed in provision 3 and 3'/4x10"rectangular ducts for exhaust from restrooms and kitchens that meet the concentration requirement of provision 3 but do not meet the size requirement. This exception is written for ducts provided without fire dampers.The through penetration detail used is tested in accordance with UL 1479 to provide sufficient heat and smoke protection equivalent to that of a fire damper(per OSSC 2014 Section 714.4.1.1.2). It is our engineering judgement that providing protection of penetrations that exceeds what is specified in the exception and is permissible and an alternate to a non-required fire damper provides fire resistance sufficient to outweigh any fire resistance lost due to the increased individual duct size of the penetration and results in a system that exceeds the fire resistance required and thereby complies with the intent of the provisions of this code. Respectfully, Brian Shea, Nate Seymour,and Mac Nelson American Heating, Inc. (503) 239-4600 brian@americanheating.net N.Seymour@americanheating.net mac@americanheating.net June 14, 2016 RE: MECHANICAL—BUILDING 1 Project Information Building Permit: MEC2016-00068 Construction Type: 5A Tenant Name: Burnham and Ash Apartments Occupancy Type: M Address: 12850 SW Ash Occupant Load: NA Area: NA Stories: 4 This letter has been written to provide an itemized response stating how each numbered issue from the initial plan review has been addressed.The plan review and corresponding responses were performed under the State of Oregon Mechanical Specialty code (OSMC) 2014 edition,the State of Oregon Fire Code (OFC) 2014 edition, and the State of Oregon Structural Specialty Code (OSSC) 2014 edition. 1) The mechanical plans have been stamped and signed by the architect of record (Josh Cabot, SERA Architects). 2) In reference to through penetrations of horizontal assemblies, OSSC 2014 Section 717.6.1 states "a duct constructed of approved materials in accordance with the Mechanical Code that penetrates a fire-resistance-rated floor/ceiling assembly that connects not more than two stories is permitted without shaft enclosure protection, provided a listed fire damper is installed at the floor line or the duct is protected in accordance with Section 714.4". Each exhaust duct is individually routed out of the building without opening into any spaces other than the space it is exhausting. Stories are not connected by these ducts.They are protected according to section 714.4.OSSC 2014 Section 714.4 refers to horizontal assembly penetrations of floors, floor/ceiling assemblies,and the ceiling membrane of a roof ceiling assembly.Section 714.4.1.1.2 states"Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479,with a minimum positive pressure differential of 0.01 inch of water(2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. 3) In reference to through penetrations of horizontal assemblies, OSSC 2014 Section 717.6.2 requires ceiling radiation dampers or a shaft enclosure to be provided to protect membrane penetrations.The following section OSSC 2014 717.6.2.1 States"Ceiling radiation dampers are not required where either of the following applies: 1. Tests in accordance with ASTM E 119 or UL 263 have shown that ceiling radiation dampers are not necessary in order to maintain the fire-resistance rating of the assembly. 2. Where exhaust duct penetrations are protected in accordance with Section 714.4.1.2, are located within the cavity of a wall and do not pass through another dwelling unit or tenant space. The exhaust ducts meet the requirements of option 2 listed above,they are located within the cavity of a wall and do not pass through another dwelling unit or tenant space. OSSC 2014 Section 714.4.1.2 states"Penetrations of membranes that are part of a horizontal assembly shall comply with Section 714.4.1.1.1 or 714.4.1.1.2. Where floor/ceiling assemblies are required to have a fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced.Section 714.4.1.1.2 states"Through penetrations shall be protected by an approved through penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479, with a minimum positive pressure differential of 0.01 inch of water(2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. 4) The dryer submittal and verification from the general contractor have been provided to demonstrate that the vent routing shown complies with the dryers that will be provided. 5) Water Heater exhaust vents and air inlets have been added to the plans including vent type (PVC),size (3"), quantity(5 of each for 5 water heaters), and spacing requirements(6"from each other). 6) Key Notes 11 and 12 have been added to clarify that the fan coils will be hung from the building structure and state how and if they will be concealed. 7) Unprotected ducts, transfer grilles,and sidewall supplies in corridors have been removed along with corresponding exhaust airflow reductions(Bike Parking 106,Storage 114), moved to fire protected outdoor air intakes(Bike Parking 113, Electrical110), or been re-designed to use FSD protected supply air as ventilation instead of exhaust air(Storage X44 stack). 8) References to OSSC 712.1.2 have been removed and replaced with references to chapter 717 and 714 as detailed in the responses to issue 2 and 3. As requested, this letter has been itemized stating how each numbered issue has been resolved, has been issued with a City of Tigard letter of transmittal,and has been delivered along with 2 copies of the revised plan. Respectfully, Nate Seymour and Mac Nelson, American Heating, Inc. (503) 239-4600 N.Seymour@americanheating.net mac@americanheating.net June 1, 2016 RE: MECHANICAL Project Information Building Permit: MEC2016-00068 5A Tenant Name: Burnham and Ash Apartments Occupancy Occupant Type:n M Address: 12850 SW Ash p M ccupant Load: Area: NA NA Stories: 4 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2014 edition; and the State of Oregon Fire Code (OFC) 2014 edition, ASCE7 and 2014 OSSC. The following corrections need to be submitted for review prior to issuing of the permit 1) Plans shall be stamped and signed by architect of record. 2) Ducts penetrating rated floor/ceiling or roof/ceiling assemblies shall comply with OSSC 717.6.1 and exception. 3) Ducts penetrating rated floor/ceiling membranes shall comply with OSSC 717.6.2. 4) Provide listing for multi-floor dryer duct. 5)-Pro.vid 6) E. . '• - - = - - - 7) All ducts, transfer grills and side wall supplies in corridors shall have smoke dampers. 8) OSSC 712.1.2 in key notes# 3 and 4 are not applicable for this building When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please h a copy of the enclosed City of Tigard, Letter of Transmittal. The letter oftransmittalc assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503) 718-2436 dann@tigard-or.gov FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT P~ . �: �� Transmittal Letter 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: upIJ t-50 ^-) DATE RECEIVED: DEPT: BUILDING DIVISION 4 FROM: KI -iY �j(= UCL_ COMPANY: A✓ .--✓z\c Ai-3 VIE NC-7 PHONE: 5O3 23°‘ -1-tGo0 ,,, . k -, - �r RE: /ac80 .,: co 6u0 vc1k4“__ i\A -C_�(D\L,- 000(92 (Site Address) (Permit Number) jU czN t W\ 'c- Pcs�} (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s)of plans. -2___ Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: I W b CoP Fsi PL5 ,(D 5c`✓zl Phi d C HJA-Nle Routed to Permit Technici. M `B Fees Due: • Yes W.- o Fee Descri i tion: Amount D ue: $ $ $ $ Special Instructions: Re•rint Permit •er PE : ❑ Yes ❑No ❑Done A• •licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT liki Transmittal Letter TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Dan Nelson DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JUN 14 2016 FROM: Nate Seymour and Mac Nelson CITY OF TIGARD BUILDING DIVISION COMPANY: American Heating, Inc. PHONE: (503) 239-4600 By. RE: 12850 SW Ash MEC2016-00068 (Site Address) (Permit Number) Burnham and Ash Apartments (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description:; 2 Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. 1 Other(explain): Itemized letter stating in what way each numbered issue has been addressed REMARKS: " FOR FIUSE ONLY Routed to Permit Techmci�ann: . Date: —7 27 1,(, Initials: 110'1.' Fees Due: ❑ Yes If.I-filo Fee Description: Amoun )ue: $ $ $ $ Special Instructions: Reprint Permit(per PE): ❑ Yes ❑No ❑ Done Applicant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form,and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT ' `+ Transmittal Letter .,.� a 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: r c - DAT DEPT: BUILDING DIVISION ��� � MAY 232016 �,c}- ���z CITY OF TIGARD FROM: nn BUILDING DIVISION COMPANY: t-1J —A -kcA- 1i ---i PHONE: 503 - 23`-‘ By:0"./ RE: ielF rte ddress ermut Num er (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s)of plans. 2_ Revisions: \, Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: CNC.Lv01_S 'rn`P?`t- —z Routed to Permit Technician: Date: 7 m ! Fees Due: ■ Yes Pro Fee Descri.tion: Amount lue: Special Instructions: Re•rint Permit .er PE : ❑ Yes ❑No ❑ Done A.•licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT il � .�, Transmittal Letter 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: TA/0 p=LSG.J DATE RECEIVED: DEPT: BUILDING DIVISION FROM: NATE. 5 p'`iM 0,42........ COMPANY: PHONE: By: /11W-2.016 RE: (Site Address) /1t)4-c-?. odt7 'Y Permit Number) (ProJctname or subdivisions nam' a and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s)of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Routed to Permit Technician:.B. '1IME Fees Due: • Yes II?r-o Fee Descri•tion: Amount sue: $ $$ $ Special Instructions: Re•tint Permit •er PE : ❑ Yes ■ No ❑Done A• •licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter Il 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: `\ N�LSo t� DATE R> CEIVED: i/ "LA ; DEPT: BUILDING DIVISION JUL 2 7 2016 ..`� x) FROM: IVAI - __O0 V--- COMPANY: 1WS -t CM i F,i c1,71ATr.—, PHONE: 5D3- 2..-75=1 `-ya do By: 1 ' RE: t640t-F,p-dk,1/4___ - A5ik over 11-14N 1caL� ms-c. 20�to- oo©co g (Site Address) (PermNum itbgr) ` 0`d C9�'l Jx t�P (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: 9__- Additional set(s)of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: C._, �e.— , ----=--1 Att v\_k-m.c,cs 5-c Routed to Permit Technician: Date: REIMIIIIIIIMIIIIIIMIEVAIII Fees Due: • Yes Leo Fee Descri'tion: Amount 0 ue: $ $ $ $ Special Instructions: Re.rint Permit I er PE : ❑ Yes ❑No ❑ Done A•e licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 - AMERICAN'r .01 HEATING,1 ING INC. 5035 SE 24`h Avenue, Portland,Oregon 97202-4765 1 J`1 V P 1503.239.4600 F 503.239.7038 • BUILT ON TRUST OREGON CCB33135: WASHINGTON AMERII*212JC/AMERIH1123R0 Letter of Transmittal TO: City of Tigard —Community Development DATE: 5.23.2016 13125 SW Hall Boulevard JOB: Burnham &Ash Tigard, OR 97223 ATTN: Dan Nelson VIA: Drop Off We are sending the following items: Date Copies Description 5.23.2016 2 Updated Burnham &Ash Mechanical Plans These are transmitted: _FOR YOUR INFORMATION _FOR ACTION SPECIFIED BELOW _AS REQUESTED _FOR YOUR USE _FOR REVIEW&COMMENT X FOR APPROVAL Remarks: These plans include the firestopping references and specific locations. Received Sent by: by: Nate Seymour Copies to: File Title: Project Manager Page 1 of 1 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 12850 SW ASH AVE, TIGARD, OR, 97223 Record Type: Record ID: Commercial - Mechanical MEC2016-00068 Inspection Type: Inspector: 699 Mechanical final Chip Barnett Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor