Permit t CITY OF TIGARD MECHANICAL PERMIT Il COMMUNITY DEVELOPMENT Permit#: MEC2016-00069 T[GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/28/2016 Parcel: 2S 102AD02900 Jurisdiction: Tigard Site address: 12790 SW ASH AVE Project: Burnham&Ash Apartments Subdivision: BURNHAM TRACT Lot: 5 Project Description: Building 2-Complete HVAC for 3-story apartment building,includes 2 retail spaces. Contractor: AMERICAN HEATING INC Owner: PREMIUM PROPERTY-TIGARD LLC 5035 SE 24TH AVE 1015 NW 11TH AVE, STE 243 PORTLAND,OR 97202-4765 PORTLAND, OR 97209 PHONE: 503-239-4600 PHONE: 503-226-1972 FAX: 503-239-7038 FEES Specifics: Description Date Amount Type of Use: MF Permit Fee 07/28/2016 $2,725.51 Class of Work: ALT Type of Const: VA Plan Review 07/28/2016 $681.38 Occupancy Grp: R-2 Occupancy Load: 12%State Surcharge-Mechanical 07/28/2016 $327.06 Stories: 3 Info Process/Archiving-Lg$2.00(over 07/28/2016 $8.00 11x17) Project Valuation: $104,000.00 Info Process/Archiving-Sm$0.50(up to 07/28/2016 $50.00 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units<10000 cfm: 3 Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 3 Heat Pump: 14 Appliances Vent Fans: 44 Vent Systems: Total $3,791.95 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: 2 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling • - . • • 1.;.:.' 344. Issued By: % -- Signature Call .-moi•-175 by 7:00 a.m.for the next available inspection date< This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application t '` FOR OFFICE USE ONLY Received City of Tigard ` 9 Permit No. g 97�2L. "a , Date/By: x7/l t 1 Ec lot 62-06(D e q 13125 SW Hall Blvd.,Tigard,OR 7z �1, NS Plan 1 e /}, ' Phone: 503.718.2439 Fax: 503 59 1960 Date/By: �' ' -7 z ( - Other Permit: It)'kW/5—DO I g s� T I GARD Inspection Line: 503.639 4175 , 5 t Date Rea.y:y: Juris: 0 See Page 2 for Internet: www.tigard-or.gova ti a T,- Notified/Method: Supplemental Information _--- _...._. CO MER L Bb h. - - EyalF WORK I�LIEE- I7SECHl� I iS1 ,. Mechanical permit fees*are based on the value of the work ❑New construction I Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all N. ❑Demolition ❑Other: mechanical materials,equipment, eq QpUme MEi�'Por,overhead,rhead,and profit. Value: t`aloe $$104,000.00 v CATEGORY OF O SFR(t- #UNEBALEPPlYSlIyISFEES ,P :: ❑ 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total ? Heating/cooling: ',.:5.:-,,, -. JOB;SI I,I� I ` ,fi IQI T A. '1I.ocATIQN. Air conditioning 46.75 Job site address:12790 SW ASH Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard OR 97234 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 'ID Suite/bldg./apt.no.:bldg2 Project name:Burnham and Ash Apartment Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 — Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 Gas fireplace/insert 33.39 -4.,,,.....,...,..,-,...9,„ bE CRII' .Lf�+ WORI ,: .- p Flue vent for water heater or gas Complete Ilvac System for aApts Bldg 2 and shell work on retail spaces fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 D`I'IIOPERTY'-OWNER, ,,, 0 , Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 1 PP IcA I' �+`CONTA PEiI S01 z ,i L Other: 23.32 Business name:American Heating Inc. Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Brandon Hutchinson Furnace,etc. Address:5035 SE 24th Ave Gas heat pump Wall/suspended/unit heater City/State/ZIP:Portland,OR.,97202 Water heater Phone:(503)239-4600 Fax::(503)239-7038 Fireplace Range E-mail:b.hutchinson@americanheating.net Barbecue � CONTRACTOR �~ . Clothes dryer(gas), - fl Business name:American Heating Inc. Other: IPIfALPERITFES9, .... Address:5035 SE 24th Ave Subtotal City/State/ZIP:Portland,OR.,97202 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)239-4600 Fax:(503)239-7038 State surcharge(12%of permit fee) CCB lie.:33135 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized Signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:Brandon Hutchinson Date: /�7/6 I:\Building\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) June 14, 2016 RE: MECHANICAL—BUILDING 2 Project Information Building Permit: MEC2016-00069 Construction Type: SA Tenant Name: Burnham and Ash Apartments Occupancy Type: M Address: 12790 SW Ash Occupant Load: NA Area: NA Stories: 3 This letter has been written to provide an itemized response stating how each numbered issue from the initial plan review has been addressed.The plan review and corresponding responses were performed under the State of Oregon Mechanical Specialty code (OSMC) 2014 edition,the State of Oregon Fire Code (OFC) 2014 edition, and the State of Oregon Structural Specialty Code (OSSC) 2014 edition. 1) The mechanical plans have been stamped and signed by the architect of record (Josh Cabot, SERA Architects). 2) In reference to through penetrations of horizontal assemblies,OSSC 2014 Section 717.6.1 states "a duct constructed of approved materials in accordance with the Mechanical Code that penetrates a fire-resistance-rated floor/ceiling assembly that connects not more than two stories is permitted without shaft enclosure protection, provided a listed fire damper is installed at the floor line or the duct is protected in accordance with Section 714.4". Each exhaust duct is individually routed out of the building without opening into any spaces other than the space it is exhausting.Stories are not connected by these ducts.They are protected according to section 714.4. OSSC 2014 Section 714.4 refers to horizontal assembly penetrations of floors, floor/ceiling assemblies,and the ceiling membrane of a roof ceiling assembly. Section 714.4.1.1.2 states"Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479,with a minimum positive pressure differential of 0.01 inch of water(2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. 3) In reference to through penetrations of horizontal assemblies, OSSC 2014 Section 717.6.2 requires ceiling radiation dampers or a shaft enclosure to be provided to protect membrane penetrations.The following section OSSC 2014 717.6.2.1 States"Ceiling radiation dampers are not required where either of the following applies: 1. Tests in accordance with ASTM E 119 or UL 263 have shown that ceiling radiation dampers are not necessary in order to maintain the fire-resistance rating of the assembly. 2. Where exhaust duct penetrations are protected in accordance with Section 714.4.1.2, are located within the cavity of a wall and do not pass through another dwelling unit or tenant space. The exhaust ducts meet the requirements of option 2 listed above,they are located within the cavity of a wall and do not pass through another dwelling unit or tenant space. OSSC 2014 Section 714.4.1.2 states"Penetrations of membranes that are part of a horizontal assembly shall comply with Section 714.4.1.1.1 or 714.4.1.1.2.Where floor/ceiling assemblies are required to have a fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced.Section 714.4.1.1.2 states"Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479,with a minimum positive pressure differential of 0.01 inch of water(2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. 4) The dryer submittal and verification from the general contractor have been provided to demonstrate that the vent routing shown complies with the dryers that will be provided. 5) Water Heater exhaust vents and air inlets have been added to the plans including vent type (PVC),size (3"), quantity(2 of each for 2 water heaters), and spacing requirements(6" from each other). 6) Unprotected corridor wall penetrations were not part of the Building 2 design. Fire Smoke Dampers have been added to the Trash (268 &368)exhaust shafts that were previously not shown. 7) References to OSSC 712.1.2 have been removed and replaced with references to chapter 717 and 714 as detailed in the responses to issue 2 and 3. 8) Exhaust and future intake louvers have been relocated to maintain 10'clearance between each other and between exhaust louvers and retail entries. 9) A note has been added to M206 to clarify the presence of Fire Smoke Dampers. As requested,this letter has been itemized stating how each numbered issue has been resolved, has been issued with a City of Tigard letter of transmittal, and has been delivered along with 2 copies of the revised plan. Respectfully, Nate Seymour and Mac Nelson, American Heating, Inc. (503) 239-4600 N.SeymourPamericanheating.net mac@americanheating.net June 1, 2016 RE: MECHANICAL Project Information Building Permit: MEC2016-00069 Construction Type: 5A Tenant Name: Burnham and Ash Apartments Occupancy Type: M Address: 12790 SW Ash Occupant Load: NA Area: NA Stories: 3 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2014 edition; and the State of Oregon Fire Code (OFC) 2014 edition, ASCE7 and 2014 OSSC. The following corrections need to be submitted for review prior to issuing of the permit 1) Plans shall be stamped and signed by architect of record. 2) Ducts penetrating rated floor/ceiling or roof/ceiling assemblies shall comply with OSSC 717.6.1 and exception. 3) Ducts penetrating rated floor/ceiling membranes shall comply with OSSC 717.6.2. 4) Provide listing for multi-floor dryer duct. 5) Provide detail of water heater exhaust. 6) All ducts, transfer grills and side wall supplies in corridors shall have smoke dampers. 7) OSSC 712.1.2 in key notes # 3 and 4 are not applicable for this building. 8) Exhaust openings to be min. 10ft. horizontally away from retail entries. 9) Provide smoke dampers at duct penetrations to lobby on first floor. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503) 718-2436 dann@tigard-or.gov Dan Nelson From: Mac Nelson <mac@americanheating.net> Sent: Wednesday,June 08, 2016 12:54 PM To: Dan Nelson Cc: Nate Seymour Subject: Burnham &Ash Apartments Permit Review Response Dan, Here is what I've put together for our response to issues 2 and 3 of your letters for Burnham &Ash (Building 1 and 2 are identical for these two issues).This is the code path we've used for the City of Portland projects (most recently Kenton Apartments) in the past to use this exhaust design. Please let me know if you have any questions about it and confirm that you are comfortable with the way it's written. 2) In reference to through penetrations of horizontal assemblies, OSSC 2014 Section 717.6.1 states"a duct constructed of approved materials in accordance with the Mechanical Code that penetrates a fire-resistance- rated floor/ceiling assembly that connects not more than two stories is permitted without shaft enclosure protection, provided a listed fire damper is installed at the floor line or the duct is protected in accordance with Section 714.4". Each exhaust duct is individually routed out of the building without opening into any spaces other than the space it is exhausting.Stories are not connected by these ducts.They are protected according to section 714.4.OSSC 2014 Section 714.4 refers to horizontal assembly penetrations of floors,floor/ceiling assemblies, and the ceiling membrane of a roof ceiling assembly.Section 714.4.1.1.2 states "Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479, with a minimum positive pressure differential of 0.01 inch of water (2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. 3) In reference to through penetrations of horizontal assemblies,OSSC 2014 Section 717.6.2 requires ceiling radiation dampers or a shaft enclosure to be provided to protect membrane penetrations.The following section OSSC 2014 717.6.2.1 States"Ceiling radiation dampers are not required where either of the following applies: 1. Tests in accordance with ASTM E 119 or UL 263 have shown that ceiling radiation dampers are not necessary in order to maintain the fire-resistance rating of the assembly. 2. Where exhaust duct penetrations are protected in accordance with Section 714.4.1.2, are located within the cavity of a wall and do not pass through another dwelling unit or tenant space. The exhaust ducts meet the requirements of option 2 listed above,they are located within the cavity of a wall and do not pass through another dwelling unit or tenant space.OSSC 2014 Section 714.4.1.2 states "Penetrations of membranes that are part of a horizontal assembly shall comply with Section 714.4.1.1.1 or 714.4.1.1.2.Where floor/ceiling assemblies are required to have a fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced.Section 714.4.1.1.2 states"Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814 or UL 1479,with a minimum positive pressure differential of 0.01 inch of water (2.49 Pa).The system shall have an F rating/T rating of not less than 1 hour but not less than the required rating of the floor penetrated".The through penetration details provided are tested in accordance with UL1479. Assuming you are comfortable with it as written,you'll receive the review letters,transmittal letters, and updated plans later this week. 1 Thanks, Mac Nelson, EIT American Heating, Inc (503)239-4600 AMERICAN HEATING OPERATES GREEN. Please consider the environment before printing this e-mail 2 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Ili . Transmittal Letter TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Dan Nelson DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JUN 14 2016 FROM: Nate Seymour and Mac Nelson CITY OF TIGARD BUILDING DIVISION COMPANY: American Heating, Inc. PHONE: (503) 239-4600 By. RE: 12790 SW Ash MEC2016-00069 (Site Address) (Permit Number) Burnham and Ash Apartments (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: 2 Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. 1 Other(explain): Itemized letter stating in what way each numbered issue has been addressed REMARKS: FORFFICUSE ONLY Routed to Permit Technicians Date: `I 'a7 Initial • iliv, t Fees Due: ❑ Yes [LhNo Fee Description: Amount D ue: $ $ $ $ Special Instructions: Reprint Permit(per PE): I I Yes ❑No n Done Applicant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT 111 ;1 Transmittal Letter 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: TA/0 )JhLSO4 DATE RECEIVED: DEPT: BUILDING DIVISION FROM: N A-I-E S f-s,1M out(� COMPANY: PHONE: By: NiSe,X016 -- 0000 RE: MtiL Number) , -00(76 y 1 (Site Address) (Permit (Pro cfnnme orsu ivision nam' a anlot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s) of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Routed to Permit Technician:, �r Y iGi,.7� Fees Due: • Yes Limo Fee Descri s tion: Amount hue: $ Special Instructions: Re stint Permit •er PE : ❑ Yes ❑No ❑ Done A• •licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY-SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. NI City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: � t3 N -LS0tJ DATE RLCEI ED:. DEPT: BUILDING DIVISION .J U L 2 7 2016 FROM: �U✓-ATF S U�&— • .;II,: iNG DIVISION COMPANY: cm-) PHONE: -'-l(0c3O By:47--71 RE: -S-12-10140c-A-1,- A.5* C14,AN ICA-C11.) rMs_C - 000Ca`a (Site Address) (Permit Number) 0 Co (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Additional set(s)of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: t Lr 1 kez_ _W v Routed to Permit Technician: Date: M Ffiii Fees Due: ■ Yes EFT() Fee Descri.tion: Amount 0 ue: Special Instructions: Re.rint Permit •er PE : ❑ Yes ❑No ❑ Done A. •licant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 _.. AMERICAN �� 5035 SE 24th Avenue, Portland,Oregon 97202-4765 HEATING, INC. P i 503.239.4600 F i 503.239.7038 / •+ OREGON CCB33135: WASHINGTON AMERII*212JC/AMERIHI123RO _► 8 U 1 L T ON TRUST Letter of Transmittal TO: City of Tigard —Community Development DATE: 5.23.2016 13125 SW Hall Boulevard JOB: Burnham &Ash Tigard, OR 97223 ATTN: Dan Nelson VIA: Drop Off We are sending the following items: Date Copies Description 5.23.2016 2 Updated Burnham &Ash Mechanical Plans These are transmitted: _FOR YOUR INFORMATION FOR ACTION SPECIFIED BELOW _AS REQUESTED FOR YOUR USE _FOR REVIEW&COMMENT X FOR APPROVAL Remarks: These plans include the firestopping references and specific locations. Received Sent by: by: Nate Seymour Copies to: File Title: Project Manager Page 1of1 13125 SW Hall Blvd. Tigard, OR 97223 City of Tigard Location: 12790 SW ASH AVE, TIGARD, OR, 97223 Record Type: Commercial - Mechanical Inspection Type: 699 Mechanical final Result: PASS- NoCofO Comments: Violation Summary: Inspector Tel: 503.718.2439 Inspection Date: Record ID: MEC2016-00069 Inspector: Chip Barnett Contractor