Loading...
Plans (40) ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND LICENSE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET A AMPERE MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN 0 (E) UTILITY METER & WARNING LABEL (6)* OR # 180498 ACALTERNATING CURRENT POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS - MP1 BLDG COOF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS ® INVERTER W/ INTEGRATED DC DISCO CONC CONCRETEDING 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 THREE LINE DIAGRAM & WARNING LABELS (3),(4),(5),(6) C COMBINER BOX MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS oc DDC DISTRIBUTIONPANEL BY PHASE AND SYSTEM PER ART. 210.5. F..,..1 DC DISCONNECT & WARNING LABELS (4),(5) RECEIVED EG DIRECT3. A NATIONALLY-RECOGNIZED TESTING C CURRENT EQUIPMENT GROUNDING CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT IN Ac AC DISCONNECT & WARNING LABELS OCT 1 7 2012 EMT(E) EXISTING COMPLIANCE WITH ART. 110.3. 1-"-1 (3),(4),(5),(6) ELECTRICAL METALLIC TUBING 4. CIRCUITS OVER 25OV TO GROUND SHALL YY h . . . G SOLAR GUARD METER COMPLY WITH ART. 250.97, 250.92 B0 BUILDINGDIVISION GALV GALVANIZED ( ) JUNCTION BOX � � °� GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER DC COMBINER BOX & WARNING GNHDD HOTO GROUNDBUILDING GALVANIZED RILDING OR ARE RUNIN METALLIC RACEWAYS GENERAL NOTES O LABELS (7),(9) OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). DISTRIBUTION PANEL & WARNING Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A 0 LABELS (1),(2) INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. LC LOAD CENTER & WARNING LABELS kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND Lc (3),(4),(5),(6) CITYARD UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. O DEDICATED PV SYSTEM METER """"""' kW KILOWATT Approved LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED Conditionally Approved..,„,,....„,[ j MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO THE 2010 OBC CONDUIT RUN ON EXTERIOR MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BASED ON THE 2009 IBC. -'-- CONDUIT RUN ON INTERIOR See Letter to:Follow [ ] 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE — GATE Attached E (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED --- INTERIOR EQUIPMENT Permit Number: `'(Z *0 a BY THE OREGON ELECTRICAL SPECIALTY CODE. 5 ' NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE Addy NIC *( B . . �� _Dar:• ' '''.l•-- NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED ) NUMBERS REFER TO LABELS Y'--- OC ON CENTER RAIL. ON CUTSHEET PAGE IPen p PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE Approved plans PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. Shall be on job Site. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. r r � SS STAINLESS STEEL IC, 1 COP SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS '3�-�, .I r.� Li +�'�r?,i SWH SOLAR WATER HEATER ,r ( ,' � ' 1 / L !L. TYP TYPICAL 4.—y. _ '4 IA UON UNLESS OTHERWISE NOTED = - - UPS UNINTERRUPTIBLE POWER SUPPLY - ” `` s i V VOLT Vmp VOLTAGE AT MAX POWER1,,,„,' -, Voc VOLTAGE AT OPEN CIRCUIT t - W WATT ,, ._ ;. - 3R NEMA 3R, RAINTIGHT �`, _ y ' fiREV BY DATE COMMENTS ,.I4 1 _I ! I- ,./1":' � I�= R/i/! t { _ lig t i , r1 i -c-- i':,. ..511'4• k �.'”- a . m J B-9721136 0 0 PREMISE OWNER AH,F. Tigard DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBERMBART �`"o!, CONTAINEDEFIT SHALL NOT BE USEDO FOR THE PHUA, CHENG PHUA RESIDENCE -���SO�at'��t o BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI 22 YINGLI ; YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array ' PART TOIZ OTHERSON, ODEIN THE RECIPIENTS ROJECT MANAGER: MOUNTING SYSTEM: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH � 3055 Oearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Las - Upslope INV94402 MENTS —SOLARCITY ,.OF SOLARCITY INC. PAYMENT TYPE: MUTER: T.(650)638-1028 F:(650)638-1029 PPA (1) POWER-ONE # AURORA PVI-5000-OUTP-US 5036640668 COVER SHEET PV 1 10/2/2012 (888)-SOL-CITY(765-2489)www.solaraty.com — Roof Mounted SEE 1 DETAILS MP1 PITCH: 24 ARRAY PITCH:24 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle Roof STORY: 2 T 20'to PL ATTACHM.a4IS S;•IAL1. BE SPACED NO GREATER THAN 24. F-iCHES ON CENTER IN ANY DIRECT:OSI WHERE ARRAY 13 V LOCATED WITHIN 3 FEET OF A ROOF EDGE.HIP EA`iE OR RIDGE. OSISC 305..1.3,D) LEGEND +T"•At..tiv : a4 SPACED NO GREATER -- GREATEFI "r' «< „-:!HES ON CENTER O (E) UTILITY METER & WARNING LABEL (6)* IN ANY DIF;EC- 3i1 WHERE ARRAY le LOCATED WITHIN 3 FEET OF A ROOFINVERTER W/ INTEGRATED DC DISCO EDGE HIP,EVE OR RIDGE. ® & WARNING LABELS (3),(4),(5),(6) MSC 305.4.3(B) DC DC DISCONNECT & WARNING LABELS (4),(5) 5'to PL AC AC DISCONNECT & WARNING LABELS FSR (3),(4),(5),(6) L — — — ;Fre seed JUNCTION BOX OC DC COMBINER BOX & WARNING LABELS (7),(9) D DISTRIBUTION PANEL & WARNING LABELS (1),(2) 0,—__7j Inv; LC LOAD CENTER & WARNING LABELS OL. �—�� 491/ (3),(4),(5),(6) M ) O DEDICATED PV SYSTEM METER J 1,-Locked Gated Fence Ll s'to PL 1—,—_, -- CONDUIT RUN ON EXTERIOR `d - CONDUIT RUN ON INTERIOR `� MF1 1c D / O GATE LI-L. ——— INTERIOR EQUIPMENT *( ) NUMBERS REFER TO LABELS �� ; ON CUTSHEET PAGE ` 112305 SW Aspen Ridge Dr I 1 Front Of House 25'to PL I I I I I, SITE PLAN N Scale: 3/32" = 1' W + E 01' 10' 21' I - S I — CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-9721136 00 PREMISE OWNER AH.1 Tigard DESCRIPTION: DESIGN: 0/4,- CONTAINED SHALL NOT BE USED FOR THE PHUA, CHENG PHUA RESIDENCE MBART �; ,, BENEFIT L ITANYONE EXCEPT SOLARCITY INC., MARKET: MULES: ,,' SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (22) YINGLI # YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Lag - Upslope 3055 aearvew9440y25an Mateo,CA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 F:(650)638-1029 PPA (1) POWER—ONE # AURORA PVI-5000—OUT)—US 5036640668 SITE PLAN PV 2 10/2/2012 (888)-SOL-CITY(765-2489)www.solarcity.com (E) 2x4 TOP CHORD ® @ 24" O.C. 4' BETWEEN / FOOTINGS / (STAGGERED) 2x4 _, f i . i I i -_ _ z i i i 2' TYP WHEN MODULES ARE WITHIN 36" OF A ROOF EDGE, (E) 2x4 RAFTERS STANDOFFS WILL BE PLACED NO MORE THAN 24" O.0 24" SPACING B FRONT VIEW OF MOUNTING PLANE 7' E' (E) 2x4 BOTTOM Scale: 1/2" = 1'-0" 1 (E) LBW CHORD ® 24" O.C. TOP CHORD: 2x4 PRE-MANUFACTURED TRUSS SUPPORT: 2x4 WEB STRUCTURE MEETS THE MAX SPAN: 8'-9" PRESCRIPTIVE REQUIREMENTS TC GRADE: 1 & btr OF THE OSISC SECTION 305.4 A SIDE VIEW OF MP1 . 4. STANDOFF Scale: 1 1/2" = 1' SOLAR PANEL INSTALLATION ORDER ATTACHED WITH MODULE NOTE: RAIL TO BE PLACED IN THE UPHILL DIRECTION , LOCATE RAFTER, MARK HOLE CLAMPS, i"-16 BOLTS, (1) LOCATION, AND DRILL PILOT AND 4" NUT --,._ HOLE. SOLARCITY SOLAR RAIL — (4)( (2) SEAL POLYURETHANE HOLE LEAWITH Sc BOLT � _ _ 3) ANT. YETI (E) COMP. SHINGLE (1) (3) INSERT ECOFASTEN FLASHING. !� (4) PLACE THE LEVELING FOOT. ..-fral --____ ECOFASTEN FLASHING (5) INSTALL LAG WITH SEALING (E) ROOF DECKING WASHER. a" DIA LAG BOLT (5) (2-i" EMBED, MIN) (E) RAFTER CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9721136 00 PREMISE OWNER: AHd Tigard DESCRIPTION: DESIGN: ib`/4, CONTAINED SHALL NOT BE USED FOR THE PHUA, CHENG PHUA RESIDENCE MBART �; ,, NORBENEFITSH OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: 'I/ SolarCity NOR SHALL IT BE DISCLOSED IN wI+oLE OR IN REST (22) YINGLI YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Lag — Upslope 3055 Clearview91402 a02San Mateo,CA _ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV. DATE PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INSERTER: T:(650)638-1028 F:(650)638-1029 PPA (1) POWER-ONE # AURORA PVI-5000-OUT)-US 5036640668 STRUCTURAL VIEWS - MP1 PV 3 10/2/2012 (888)-SOL-CITY(765-2489)www.solaraty.com UPLIFT CALCULATIONS INPUT VARIABLES CALCULATIONS AND VALUES Required Variables Design wind pressures based upon: Mean Roof Height: 26 ASCE 7-05 Chapter 6 Wind Loading Exposure Category: B Equation 6.5.13.3: Component and Cladding Elements Basic wind speed(or city in the future): 95 Wind pressure P=qh*Cn*G Importance factor(1 for residential): 1 6.5.10: Velocity pressure qh=0.00256*Kz*Kzt*Kd*VA2*I Roof shape: Pitched From Table 6-3: Roof Angle(degrees): 24 Kz=0.76 Roof zone: 3 From Figure 6-4: Contiguous sq.feet of array: 215.6 Kzt=1.5 Least width of the building: 41.99 Obstructed wind flow? False From Table 6-4: Kd=0.85 Local Topographical Features (choose "standard"or refer to pictures right, and below) From figure 6-1: V=95 Type of hill: Standard Hill height(h)(ft): From table 6-1: Slope of hill(degrees): I-1 Horizontal distance from hilltop to house(x): From Velocity Pressure Equation Height from bottom of hill to mean roof height(z): qh=22.39 Design Wind Pressure From Figure 6-19B P(lbs. per sq.ft.)=qh*Cn*G Cn(uplift)=-0.98 Pd(downforce pressure)= 23.22 Cn(down)= 1.22 Pu(uplift pressure)= 18.65 From 6.5.8.1 G=0.85 Max Tributary Area Feet Inches Arrays consist of modules in portrait and landscape X(E-W distance between standoffs)= 0 48 Yingli YL240P-29b Black Y(N-S distance between standoffs)= 0 30 Amax(sq.ft.)=0.5*L*X Staggered Penetrations= No L(length of panel in ft. perpendicular to rail) 5.42 Module Rail Max. Span/Cantilever(in)= 64 23 X= 4 Y= 2.5 Max Uplift Force on a Single Standoff L= N/A Pmax(lbs.)=Amax*Pu Amax= 10.83 202.03 Dead Load Calculations Factor of safety=FI*D*NI/Pmax DL(lbs/sq.ft.)=(Mm+Mh)/(L*W) 5/16 x 4 in. =Lag size and length 984.16 =Capacity(lbs)of 1 lag(NDS) L(length of modules) 5.42 1 =NI(number of lags per standoff) W(width of modules)3.25 4.87 =Factor of safety Mm (weight of modules)43.6 Point Load Calculations Mh(weight of hardware per module)= 6 PL(lbs)=Amax*DL DL= 2.82 30.52 J B-9 7 2113 6 0 0 PREMISE OWNER: AHJt Tigard DESCRIPTION: DESIGN: -1,64 CONFIDENTIAL— THE INFBEORMATION HEREIN JOB NUMBER: PHUA, CHENG PHUA RESIDENCE CONTAINED OF SHALL NOT USED FOR THE MBART ',/,�o'� '� U BENEFIT ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (22) YINGLI # YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array PART TOIZ OTI N, EXCEPTS OUTSIDE THEORECIPIENTS WITH PROJECT MANAGER MOUNTING SYSTEM: TIGARD, OR 97224 ORGANIZATION, IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Lag — Upslope 3055 Oearview Way San Mateo,CAX402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INIERTER: T:(650)638-1028 F:(650)638-1029 PPA (1) POWER—ONE # AURORA PVI-5000—OUTD—US 5036640668 UPLIFT CALCULATIONS PV 4 10/2/2012 (888)-SOL-CITY(765-2489)wwwsolarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE 30ND (N) #6 GEC TO (E) UFER AT PANEL (E) 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 —(1)POWER-ONE#AURORAPV1-5000-OUTD-US LABEL; A —(22)S1NGU/YL240P-29b OR # 180498 WITH IRREVERSIBLE CRIMP (E)) 200/2P MAIN CIRCUIT BREAKER Inverter, 5000W,240V,96.5% Voc: 37PV5adue(-2011); 240W,215.9W PTC,H4,501,114,Black Frame Panel Number:BXH34/K INV 2 Vpmax:29.5 Meter Number:23126239 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Underground Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL (E) WRING Inverter 1 IND COOPER W 200A/2P Meter Socket n POWER—ONE Dc.,DO NOT ADJUST MIN.ACTIVATION V TAGE 0 (E) LOADS A AURORA PVI-5000—OUTD—US DCC 1 String(s)Of 11 On MP 1 240V / • � I4—ii Li •� GFP/GFCI DC+ • • • 1 r ill N -�� DC- I 2 DO NOT ADJUST MIN.ACTIVATION V TAGE I' 30A/2P -- EGC/ DC+ DC+ I4 I4 �� A I - GND -— GEC O DC_ - DC- 1 String(s)Of 11 On MP 1 B V • • I I GND I____EGC — EGC 1- V U N J0 EGC/GEC j z-6 — T GEC 1 TO 120/240V SINGLE PHASE I UTILITY SERVICE II I POI-(1)SQUARE D#1101,4230 2 PV BACKFEED BREAKER A -(1)COOPER I B Line Meter Socket 011 ^ D� Breaker; 30A/2P,2 Spoors Meter Socket 125A,4-14AWG,Ring Type -(1)AW CAP; B-Lkie Meter Socket Accessory —(1)MILBAII</CL200 Meter, FORM 2S (1)AWG#10,THWN-2,Black (2)ARC if10,PV WIRE,Block Voc =412.5 VDC Inc =8.65 ADC O I �(1)AWG�D,7HWN-2,Red O 5'—(1)AWG#10,Solid Bare Copper EGC Vmp =324.5 VDC Imp=8.14 ADC (1)AWG/ID,THWN-2,White NEUTRAL Vmp =240 VAC Imp=20.83AAC (1)Conduit Kit; 3./4'EMT —(1)AWG#6,T1.01WI-2,Green EGC/GEC —(1)Conduit Kit; 3/4'EMT (2)AWG/l0,PV WIRE,Black VOC =412.5 VDC Isc =8.65 ADC O w-(1)AWG p0.Saw Bare Copper EGC Vmp =324.5 VDC Imp=8.14 ADC (1)Conduit Kit; 3y4'DAT CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: MU Tigard DESCRIPTION: DESIGN: `Ibk/4' JB-9721136 00 MBART ■ CONTAINED SHALL NOT E USED FOR THE PHUA, CHENG PHUA RESIDENCE .r/, S��a��t o BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (22) YINGLI # YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 1 THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Lag — Upslope 3055 OearvewWa0y25an Mateo,CA 9 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF SOLARCITY INC. PAYMENT PPA YPE: !WRIER: N(1)POWER—ONE # AURORA PVI-5000—OUT)—US THREE LINE DIAGRAM PV 5 10/2/2012T:O50)C Y(76 -2 89)www.8-1029 5036640668 (BBs)-SOL-cm(-1028 F:( 50)638l1029.com 1. Conductor Sizing per Art ELECTRICAL CALCULATIONS - a. Conductor must have 30o deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). Module: 22 Yingli YL240P-29b Black 215.9 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 Power-One PVI-5000-S 0.965 5000 4583.56 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) b. Conductor must have (after corrections for conditions of use) >= Module: S Imp(A) Max.Length(ft) Wire continuous current per Table 310.15(B)(16). Inverter 2: String: 18.14 65 AWG_10 at Max Ave 1-1i:89 deg F Module: Vdrop= (8.14 * 130 *0.001240hms) / 255.86825 0.51 Inverter 3: Branch: 8.14 I 0 I AWG_10 at Max Ave Hi:89 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Module: Vdrop= (8.14 *0 *0.001240hms) / 255.86825 0 Ampocity of wire derated for conditions of termination must be >= Inverter 4: Total voltage drop in DC conductors= 0.51 continuous current*1.25. All string terminations are rated at 90' C. Inverter: 8.14 I 15 AWG_10 at24OV Vdrop= (8.14 *30 *0.0012 Ohms) / 240 V 0.1221 Total: 22 Modules Total Inv Pwr: 5000 4583.56 PTC Combined:I 0 I 0 I I at 240V 2. OCP Sizing per Art 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC: 5280 Vdrop= (0 *0 Ohms) / 240 V 0 a. Round up to next size per Art 240.4(B) Voc: 37.5 V deg F deg C Vmp: 29.5 V Record Low Temp: 23 -5 Total voltage drop in AC conductors= 0.12 3. Conductor Sizing per Art 690.8(B)(1) !so: 8.65 A Max Average Hi Temp: 89 i 32 Total voltage drop in AC and DC conductors= 0.63 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp: 8.14 A Record Hi Temp: 98 37 current per Art 215.2(A)(1). Tvoc: -0.13875 V/degC Tisc: 5.19 mA/deg C b. Conductor must have (after corrections for conditions of use) >= String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 0 Voc Correction Factor: continuous current per Table 310.15(6)(16). TYPE_A_INV 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 90 11 Yingli YL240P-29b Black 11 modules per series string 11 modules per series string Voc= 412.5 Min Vmp at Max Temp: 255.87 Voc= 412.5 V Voc= 412.5 V c. Evaluate conductor temperature at terminations per Art 110.14(C). Max Voc at Min Temp: 458.29 Ampacity of wire derated for conditions of termination must be >= Vmp= 324.5 Inverter Max Vdc Input: 600 Vmp= 324.5 V Vmp= 324.5 V continuous current*1.25. All branch terminations are rated at 75' C Isc= 8.65 Max String Size: 14 Isc= 8.65 A Isc= 8.65 A min. Imp= 8.14 1-way wire length: 65 Imp= 8.14 A Imp= 8.14 A lcont= 10.81 Art 690.8(A)(1) lcont= 10.81 A lcont= 10.81 A Art 690.8(A)(1) 4. OCP Sizing 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 2: AWG_10 PV Wire Icont*1.25=(Amps) 13.52 Conductor 1 Conductor 2 30 deg C ampacity= 40 (cont*1.25=(Amps) 13.52 13.52 5. Conductor Sizing per Art 690.8(B)(1) 1.b Icont=(Amps) 10.81 30 deg C ampacity= 40 40 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Start ampacity 40 2.b lcont=(Amps) 10.81 10.81 current per Art 215.2(A)(1). Temperature derate(%=F) - 0.71 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.76 0.76 b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 28.4 Conduit fill derate(%=#) 1 1 continuous current per Table 310.15(8)(16). 1.c Derated ampacity 30.4 30.4 Icont*1.25=(Amps) 13.52 2.c Term 1 Term 2 Ampacity 40 Temp table 75degC 75degC c. Evaluate conductor temperature at terminations per Art 110.14(C). (cont*1.26-(Amps) 13,52, 13.52 Ampacity of wire derated for conditions of termination must be >= 1.d Icont*1.25=(Amps) 13.52 Ampacity 35 35 continuous current*1.25. All inverter output terminations are rated at OCP Size= 15 1 75' C. Inverter Type A Output 2.d OCP Size= 15 15 Power-One PVI-5000-S 1 way wire length: 10 ft Combined Inverter Output 6. OCP Sizing (cont= 20.83 A Art690.8(A)(1) Service Voltage= a. Round up to next size per Art 240.4(B) 3.a Icont*1.25=(Amps) 26.04 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 30 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) 7. Conductor Sizing per Art 690.8(B)(1) 4.a Icont*1.25=(Amps) Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous (cont*1.25=(Amps) 26.04 -- OCP size= Art 240.6(A) 3currentper Art 215.2(A)(1). Ic deg( ampacity= 40 4.b Conductor: THWN-2 at 90 degC:Table 310.16 3.c Icont=(Amps) 20.83 Icont*1.25=(Amps) Start ampacity 40 b. Conductor must have (after corrections for conditions of use) >= Temperature derate(%=F) 0.91 30 deg C ampacity= continuous current per Table 310.15(B)(16). Conduit fill derate(c%o=#) 1 4.c Icont=(Amps) Derated ampacity 36.4 Start ampacity 3.d Icont*1.25=(Amps) 26.04 Temperature derate(%=F) c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacit 35 Conduit fill derate(%=#) Ampacity of wire derated for conditions of termination must be >= y Derated ampacity continuous current*1.25. All inverter output terminations are rated at 4.d Icont*1.25=(Amps) 75' C min. Ampacity CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9721136 00 PREMISE OWNER AHL Tigard DESCRIPTION: DESIGN: %kid CONTAINED SHALL NOT BE USED FOR THE PHUA, CHENG PHUA RESIDENCE MBART - - NENEST OF ITANYONEDI EXCEPT SOLARCITY INC., MARKET: MODULES: /',,,,Solas( qty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (22) YINGLI # YL240P-29b 12305 SW ASPEN RIDGE DR 4.32 KW PV Array 'i� PART TO OTHERS OUTSIDE THE RECIPIENTS TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE SC Yeti: 1 Lag - Upslope 3055 aearview Way San Mateo,CA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE PAYMENT TYPE: INVERTER: T:(650)638-1002(650)638-1029 PERMISSION OF SOLARCITY INC. PPA (1) POWER-ONE # AURORA PVI-5000-OUT)-US 5036640668 ELECTRICAL CALCULATIONS PV 6 10/2/2012 (888)-SOL-CITY(765-2489)www.solarcity.com YL240P-29b CEB . YG E 240 YL:: : - YINGU SOLAR SERIES YL225P-29b Y� OFFICIAL SPONSOR FIFA WORLD CUP .. boost( COMPANY Yingli Green Energy(NYSE:YGE) is one of the world's largest fully vertically integrated PV manufacturers.With over 2 GW of modules installed globally,we are a leading solar energy company built upon proven product reliability and sustainable performance. Founded in 1998,Yingli Green Energy serves customers through our U.S. subsidiary,Yingli Americas, co-headquartered in New York and San Francisco.We are the first renewable energy company and the ` — first Chinese company to sponsor the FIFA World CupT'. PERFORMANCE -Industry leading in-house manufacturing of polysilicon, ingots, wafers, cells and modules ensures tight control of our material i and production quality. -High performance, multicrystalline solar cells deliver a module series efficiency of up to 14.7%, reducing installation costs and maximizing the kWh output per unit area. Ii -Power tolerance of+/-3%minimizes PV system mismatch losses. QUALITY & RELIABILITY I �.. Robust, corrosion resistant aluminum frame independently tested to withstand wind and snow loads of up to 50 psf and 113 psf, I respectively, ensuring a stable mechanical life. i Manufacturing facility certified to IS09001 Quality Management System standards. I -Module packaging optimized to protect product during transportation and minimize on-site waste. WARRANTIES -Extensive 5-year limited product warranty and a 25-year limited power SILVER FRAME BLACK FRAME warranty. Limited power warranty*= 90%of the minimum rated power output .„÷,„t,..,. for 10 years, 80%of the minimum rated power output for 25 years. *In compliance with our warranty terms and conditions. QUALIFICATIONS & CERTIFICATES UL 1703 and ULC 1703,UL Fire Safety Class C,CEC,FSEC,ISO 9001:2008, ISO 14001:2004,BS OSHAS 18001:2007,SA8000 C UL US (C,"''' Cfi J� :�• LISTED ' C r— oHc,eve�la40Dc rnece❑ ��"WM' DNV MI D ___..-... YINGLISOLAR.COM Yingli Americas YGE24O SERIES ELECTRICAL PERFORMANCE GENERAL CHARACTERISTICS Module name YGE 240 YGE 235 YGE 230 YGE 225 Dimensions(L/W/H) 64.96 in(1650 mm)/38.98 in(990 mm)/ Module type YL240P-29b YL235P-29b YL230P-29b YL225P-23b 1'97 in(50 mm) - Power output Pm.. W 240 235 230 225 Weight 43.0 lbs(19.5 kg) Power output tolerances° APm.. % +/-3 Module efficiency r1m % 14.7 14.4 14.1 13.8 Voltage at Pmax Vamp V 29.5 29.5 29.5 29.5 PACKAGING SPECIFICATIONS Current at Pmax Imp° A 8.14 7.97 7.80 7.63 Number of modules per pallet 20 Open-circuit voltage V,. V 37.5 37.0 37.0 36.5 Number of pallets per 53'container 36 Short-circuit current I.. A 8.65 8.54 8.40 8.28 - a "--"- Packaging box dimensions(L/W/H) 67 in(1700 mm)/45 in(1150 mm)/ 'STC:1000W/i&irradiance,25°C module temperature,AM 1.5g spectrum according to EN 60904-3 'Premium power output tolerance options are available upon request 47 in(1190 mm) Box weight 941 lbs(427 kg) Electrical parameters at Nominal Operating Cell Temperature(NOCT) Power output Pm.. W ' 174.3 170.7 167.0 163.4 _ Units:inch(mm) Voltage at Pna. Vmpp V 26.6 26.6 26.6 26.6 Current at Pm.. leap A 6.56 6.42 6.29 6.15 �_.. -._ 38.98(990) Open-circuit voltage V« V 34.2 33.8 33.8 33.3 37.24(946) 1.97(50) Short-circuit current Lu :: A 7.01 6.92 6.81 6.71 -4 I NOCT:open-circuit operating cell temperature at 800W/m'irradiance,20°C ambient temperature,1 m/s wind speed :1-1 THERMAL CHARACTERISTICS m ..--- 8 --- _ Nominal operating cell temperature NOC7 °C 46+/-2 N w Temperature coefficient of Pm.. y %/°C -0.45 Grounng holes ® diN n Temperature coefficient of V« By_ %/°C -0.37 2-00.236(6) o '2 p v _ s. Temperature coefficient of 1.. as, %/°C 0.06 a OPERATING CONDITIONS Mounting xo Max.system voltage 600V0c0.-- 0- Max.series fuse rating 15A Drainage holes i +I Operating temperature range -40 to 194°F(-40 to 90°C) $ 8-00.157(4) Q A A n Y ` . ' .R l l Max.static load,front(e.g.,snow and wind) 113 psf(5400 Pa) , -t-Q Max.static load,back(e.g.,wind) 50 psf(2400 Pa) ...,...----- -......._-__. �'�0.47(12) \MI �� Hailstone impact 1 in(25 mm)at 51 mph(23 m/s) i' ', / CONSTRUCTION MATERIALS ; N 1' Inc SECTION A-A I Front cover(material/type/thickness) Low-iron glass/tempered/3.2 mm 1 1 Cell(quantity/material/type/dimensions/area) 60/polysilicon/multicrystalline/ tt / 156 mm x 156 mm/243.3 cm' ` /-- / Encapsulant(material) Ethylene vinyl acetate(EVA) i/ 1.26(32) - Frame(material/color) Aluminum alloy/anodized silver or black - Junction box(protection degree) IP65 © Warning:Read the Installation and User Manual in its entirety Cable(type/length/gauge/outside diameter) PV Wire/47.24 in(1200 mm)/12 AWG/0.244 in(6.2 mm) before handling,installing,and operating Yingli modules. Plug connector Amphenol/H4/IP68 (manufacturer/type/protection degree) Our Partners •The specifications in this datasheet are not guaranteed and are subject to change without prior notice. Yingli Green Energy Americas, Inc. info@yingliamericas.com x` Tel: +1 (888)686-8820 YINCi!lLAR - YINGLISOLAR.COM NYSE:YGE L. OFFICIAL SPONSOp ieaMa... 6r Sit Yingli Green Energy Holding Co.Ltd. I YGE240Series_EN_201107_v01 Powe-DIW® A R RA G `JRenewable Energy Solutions PVI-5000-OUTD PVI-6000-OUTD 0 GENERAL SPECIFICATIONS OUTDOOR MODELS oC CeC Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW. ' This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power - F tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1%. The wide input voltage range makes the inverter suitable to low _ .1110111 power installations with reduced string size.This outdoor inver • `- ter has been designed as a completely sealed unit to withstand the harshest environmental conditions. 000 eaturesI I- • Each inverter is set on specific grid codes which can be selected in the field • Single phase output • Dual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in different directions • Wide input range • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range • Outdoor enclosure for unrestricted use under any environmental conditions • RS-485 communication interface(for connection to laptop or datalogger) • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP AURORA UNO 1 TECHNICAL DATA Values PVI-5000-OUTD-US PVI-6000-OUTD-US Rated Grid AC Voltage I V 208 240 277 208 240 277 Input Side(DC) 4,'.' r 7 ` Maximum Usable Power for Each Channel W 4000 4000 MPPT Voltage Range V 200-530 200-530 Start-Up Voltage V 200(adj.120-350) 200 (adj.120-350) Absolute Maximum Voltage(Vmax) V 600 600 Maximum Current(Idcmax)for both MPPT in Parallel A 36 36 Maximum Usable Current per Channel A 18 18 Number of Wire Landing Terminals per Channel 1 1 Number of Independent MPPT Channels 2 2 Array Wiring Termination Screw terminal block Screw terminal block 3 Knock-Outs:1h or 1"(w/Ring Reducer.) 3 Knock-Outs:1/z or 1"(w/Ring Reducer.) Output Side(AC) Grid Standard 10/2W or Split-0/3W 10/2W or Split-0/3W Nominal Power W 5000 6000 Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency;Range** Hz 60;(59.3-60.5) 60;(59.3-60.5) Maximum Current(lac,max) A 27 23 20 30 28 24 Power Factor >0.995 >0.995 Total Harmonic Distortion At Rated Power % <2 <2 Efficiency Maximum Efficiency % 97.1 97.1 CEC Efficiency % 96 96.5 96.5 96 96.5 96.5 Operating Parameters Consumption in Stand By(Night) WRMS <8.0 <8.0 Consumption During Operation WRMS 20 20 Topology Transformerless Transformerless Mechanical Specifications Enclosure rating NEMA 4 NEMA 4 Cooling Natural Convection Natural Convection Conduit Connections Trade size KOs:(2eax1/2")and Trade size KOs:(2eax1/2")and (2ea x 1-1/4',3 places side,front,rear) (tea x 1-1/4,3 places side,front,rear) Grid Wiring Termination Type Screw Terminal Block Screw Terminal Block Single wire,90°C terminal wiring Single wire,90°C terminal wiring Dimensions(W/H/D) in(mm) 12.8 x41.4x 8.7(325 x1052 x 222) 12.8 x41.4x 8.7(325 x1052 x 222) Unit Weight lb(kg) <59.5(27.0) <59.5(27.0) Shipping Weight lbs(kg) 78(35.4) 78(35.4) Mounting System Wall bracket Wall bracket Environmental Ambient Air Temperature Range F1°C) -13...+140(-25...+60)with derating above 122(50) -13...+140(-25...+60)with derating above 122(50) Accoustic Noise Emission Level db A@ 1 m <50 <50 Relative Humidity %RH 0-100 condensing 0-100 condensing Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) Protection Devices Output Anti-lslanding Protection According to UL 1741/IEEE 1547 According to UL 1741/IEEE 1547 External AC OCPD Rating ARMS 35 30 25 40 35 30 Over-Voltage Protection Type Varistor,2(L-N/L-PE) Varistor,2(L-N/L-PE) Input Reverse Polarity Protection Yes Yes Maximum Short Circuit Current Limit per Channel A 22 22 Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI Pre start-up Riso and dynamic GFDI (Requires Floating Arrays) (Requires Floating Arrays) DC Switch Current Rating(Per Contact) A/V 25/600 25/600 Isolation Level Transformerless(Floating Array) Transformerless (Floating Array) Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 Safety Approval cCSAus cCSAus Features-Communication User-Interface(Display) 16 characters x 2 lines LCD display 16 characters x 2 lines LCD display Remote Monitoring(1xRS485 incl.) AURORA-UNIVERSAL(opt.) AURORA-UNIVERSAL(opt.) Wired Local Monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.),PVI-DESKTOP(opt.) PVI-USB-R5485_232(opt.),PVI-DESKTOP(opt.) Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) Standard Warranty Years 5 5 Available Models Standard-With DC Switch-Floating Array PVI-5000-OUTD-US PVI-6000-OUTD-US .All data is subject to change without notice "Adjustable low trip point to 511-1z.Contact manufacturer for details AURORA UNO 3 • PHOTOVOLTAIC DC DISCONNECT Label Location: PHOTOVOLTAIC POINT OF INTERCONNECTION Label Location: WARNING! ELECTRIC SHOCK HAZARD! Per Code:(DC), ) WARNING! ELECTRIC SHOCK HAZARD! (P01) DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE Voc V CEC 690.53 LINE AND LOAD SIDE MAY BE ENERGIZED Vmp V PV POWER SOURCE Isc A 'MAXIMUM AC CIRCUIT OUTPUT A OPERATING CURRENT ett- Imp A OPERATING AC VOLTAGE v SolarCity (888)SOL-CITY SOLARCITY.COM 14SolarCity (888)SOL-CITY SOLARCITY.COM Label Location: (DC), (INV), (AC), (LC) Label Location: Solar Disconnect Per Code: PV COMBINER BOX (CB) CEC 690.17 WARNING: WARNING- Electric Shock Hazard ELECTRIC SHOCK HAZARD DO NOT TOIIJCH TERMINALS Terminals onboth line and Load sides may be energized in the Open Position Label Location: WARNING! (P01) INVERTER OUTPUT CONNECTION.DO NOT RELOCATE THIS OVERCURRENT DEVICE. Label Location: WARNING - Dual Power Sources (INV), (AC), (LC), (M) Label Location: Second source is photovoltaic system PHOTOVOLTAIC AC DISCONNECT (AC), (D), (LC) WARNING! ELECTRIC SHOCK HAZARD! Per Code: CEC 690.8.A.3 & CEC 690.54 Label Location: OPERATING AC VOLTAGE V WARNING - Electric Shock Hazard (CB) MAXIMUM OPERATING CURRENT A No user serviceable parts inside /✓ Contact authorized servicer for assistance - (8'C '�� SolarCity S08LARCI8) OTY.COM Label Location: DC DISCONNECT (DC), (INV), (AC), (LC) Label Location: CAUTION: SOLAR CIRCUIT (C) WARNING -Electric Shock Hazard DO NOT TO CH TERMINALS Terminals on bot Zine and Load sides may be energized in the Open Position (AC): AC Disconnect DC VOLTAGE IS ALWAYS PRESENT WHEN (C): Conduit SOLARMODULES ARE EXPOSED TO SUNLIGHTC (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR %kid, 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �� San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Labels T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVESolarCity (888)-SOL-CIfY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Page-file=-- \,,o 'Renewable Energy Solutions f J RO R A PARAMETER PVI-5000-OUTD-US PVI-6000-OUTD-US ) PVI-5000-OUTD-U5 Input Side Absolute Maximum DC Input Vohage(V„,„,,,) 600 V /�i/y!,{/�■[}�, (^■f T Start-up DC Input Voltage(V,,,„) 200 V(adj.120...350V) PVI-O V M V-V U [ -■ ■'e Operating DC Input Voltage Range(Va�,n...Vm„) 0.7 xV a ..580V 1R U r�wa�, Rated DC Input Power(Pao) 51 SO W 6180 W Q Number of Independent MPPT 40 2 W O Maximum DC Input Power for each MPPT(Pa .,.) DC Input Voltage Range with Parallel Configuration of MPPT at P.,, 200...530 V £ :` "v'aw . D DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null[530VsVupp,s580V) Q4000W[225VsVM„rs530V] 4000W[230VsVm,,,5530V] DC Power Limitation for each MPPT with Independent the other channel:P -4000W the other channel:Pe,-4000W GENERAL Configuration of MPPT at P„„max unbalance example [90V5VM„�530V] [720V5VM„rs53V] (''�� ' ('�("�SPECIFICATIONS(I'� Maximum DC Input Current(h.m,J/for each MPPT(IM,,.m„) 36.0 A/18.0 A OUTDOOR I n 0 D E L.S '� Maximum Input Short Circuit Current for each MPPT 22.0 A I V I lJ Number of DC Inputs Pairs for each MPPT 1 < DC Connection Type Screw Terminal Block,3 Knock-Outs:11/2"or 1"(w/Ring Reducer) Input Protection Reverse Polarity protection Yes,from limited current source 0 Input Over Vohage Protection for each MPPT-Varistor 2 kai� Photovoltaic Array Isolation Control GFDI(for use with either Positive or Negative Grounded Arrays) DC Switch Rating for each MPPT(-S Version) 25 A/600V mcv Output side 208V 240V 277V 208V 240V 277V AC Grid Connection Type Single phase/Split phase Rated AC Power(P,,,) 5000 W 6000 W Designed for residential and small commercial PV Maximum AC Output Power(P„,,,„) 5000W 6000W g Rated AC Grid Voltage(V,,,,l 208V 240V 277V 208V 240V 277V installations, this inverter fills a specific niche in the • AC Voltage Range 183...228V 211...264V 244...304V 183...228V 211...264V 244...304V Aurora product line to cater for those installations producing Maximum AC Output Current(I,,,,,.) 27.0 A 23.0 A 20.0A 30.0 A 28.0 A 24.0 A Rated Output Frequency(f,) 60 Hz between 5kW and 20kW. ,;; � s Output Frequency Range(fm....f,,.,) 59.3...60.5 Hz Nominal Power Factor(Cosphi,,,,) >0.995 This inverter has all the usual Aurora benefits,includingdual Total Current Harmonic Distortion 2% AC Connection Type Screw terminal block input section to process two strings with independent MPPT, a;." Output Protection x. 1.; 208V 240V 277V 208V 240V 277V " ` Anti-Islanding Protection According to UL 1741/IEE1547 high speed and precise MPPT algorithm for real-time power ` Maximum AC overcurrent Protection 35.0A 30.0A 25.0A 40.0A 35.OA 30.OA tracking and energy harvesting,as well as transformerless Outputovervohage Protection-Vanstor 2(LI-L2/L1-PE) operation for high performance efficiencies of up to 97.1%. ' Operating Performance „, sx:.,, 208V 240V 277V 208V 240V 277V Maximum Efficiency(nm,.) 97.19,0 97.1 0/0 l Weighted wee Th Threshold 96.0% 96.5% 96.5% 960% 96.5% 96,5% The wide input voltage range makes the inverter suitable to J Feed In Powerrhre:hold 20.0 W Stand-by Consumption <8.0 W low power installations with reduced string size.This outdo- - communication , ,,. it ; ,;k„ :,i, or inverter has been designed as a completely sealed unit to Wired Local Monitoring PVI-USB-RS485_232(opt)PVI-DESKTOP(opt.) withstand the harshest environmental conditions. Remote Monitoring PVI-AEC-LVO(opt.),AURORA-UNIVERSAL(opt) Wireless Local Monitoring _ PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) s.. User Interface 16 characters x 2 lines LCD display Environmentals 4 :Z tea` ., Ambient Temperature Range 25...+60°C(-13.-+140°F)with derating above 50°C(122°F) Relative Humidity 0...100%condensing - - '--' Noise Emission <SOdb(A)@im .,,-.- .,,,, .,., ...... ,_ ,,,., - ._ ,x .,.., .M ., . ' Maximum Operating Altitude without Derating 2000 m/6560 ft - Physical Environmental Protection Rating IP 65 * idoollow Cooling Natural tears Dimension(H x x DI 1052mm x 325mm x222mmm/41.4"x12.8"08.7" Weight <27.0 kg/59.5 lb Mounting System Wall bracket Safety t Each inverter is set on specific grid codes which can be selected in the field Isolation Level Transformerless t Single phase output Marking cCSAus Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 t Dual input sections with independent MPP tracking, allows optimal energy harvesting from two Grid Standard IEEE 1547 sub-arrays oriented in different directions Available Products Variants t Wide input range With DC Switch PVI-5000-OUTD-US PVI-6000-OUTD-US 4 High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable 41i performance across the entire input voltage and output power range • Outdoor enclosure for unrestricted use under any environmental conditions ,;, RS-485 communication interface(for connection to laptop or datalogger) • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP A1IRQRA.VNQ ,ro.1 CSA INTERNATIONAL Certificate of Compliance Certificate: 1841082 Master Contract: 173688 Project: 2439384 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rob-Hempstadc, Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-6000-OUTD-US,PVI-6000-OUTD-US-W and PVI-5000-OUTD-US, permanently connected. For details related to rating,size,configuration,etc.reference should be made to the CSA Certification Record, Annex A of the Certificate of Compliance,or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment For Use With Distributed Energy Sources(January 28,2010) DQD 507 Re,2009-09-01 Page:I YGE24O YL240P--296296 CEO YL235P � YGE 240 SERIES YL230P-29b YIN c-11-1.■LAR2°" SERIESYL225P-296 :L ELECTRICAL PERFORMANCE OFFIcw-"°N$OR nrAwORLO CUP Brasil 131=1222322=222=.111=1111111.1.11 GENERAL CHARACTERISTICS Module name YGE 240 YGE 235 YGE 230 YGE 225 Dimensions(IJW/H) 64.96 in(1650 mm)/38.98 in(990 mm)/ Module type Y1240P-29b YL235P-29b YL230P-29b li YL225P.23b 1.97 in(50 mm) _. - ° -240 '.. 1,, 225 Weight 's 43.0 lbs(19.5 kg) Power output Pm.. W 235 230 ' COMPANY Power output tolerances' LPma, / +/-3 Yingli Green Energy(NYSE:YGE)is one of the world's largest fully Medaaettl<ien y nm r 14.7 14.4 14.1 13.8 vertically integrated PV manufacturers.With over GW of modules warp atPmax we, V 29.5 29.5 29.5 I 29.5 PACKAGING SPECIFICATIONS """• `' '" '?• Current at Pmax I.PP A 8.14 7.97 7.80 7.63 Number of modules per pallet 20 installed globally,we are a leading solar energy company built upon Open-circuit voltage V. V 37.5 37.0 37.0 36.5 Number of proven product reliability and sustainable performance.Foundedpallets per 53'container 36 Short-circuit current Ie A 8.65 8.54 8.40 8.28 in 1998,Yingli Green Energy serves customers through our U.S. Packaging box dimensions(L/W/H) 67 in(1700mm)/45in(1150mm)/ 'STC:1000WMV irradiance,25'C module temperature,AM 1 S spectrum according to EN 60904-3 47 in(1190 mm) subsidiary,Yingli Americas,co-headquartered in New York and 'Premium pourer output tolerance options are available upon request San Francisco.We are the first renewable energy company and the Box weight 941 lbs(427 kg) Electrical -meters at Nominal Operating Cell Temperature(NOCT)first Chinese company to sponsor the FIFA World Cup-. Power output Pemo W ; 174.3 170.7 167.0 163.4 Units:inch(mm) PERFORMANCE Voltage at Pm.. Vmw V 26.6 26.6 26.6 26.6 __. .-... ._ __---___ 38.98(990) Current at Pm.. kw A 6.56 6.42 629 6.15 e 0 -Industry leading in-house manufacturing of polysilicon,ingots, open-circuit voltage V. V 342 33.8 33s 33.3 37.24(946) .-- 1.97(50) wafers,cells and modules ensures tight control of our material Short-circuit current I. A 7.01 6.92 6.81 6.71 g 4 and production quality. NOCE open.nirwit operating cell temperature at 808W/m'irradiance,20`C ambient temperature,1 m/s vend speed ri - High performance,multicrystalline solar cells deliver a module series efficiency of up to 14.7%,reducing installation costs and maximizing THERMAL CHARACTERISTICS L 5 the kWh output per unit area. Nominal operating cell temperature NOCT 'C 46+/-2 H gt -Power tolerance of+/-3%minimizes PV system mismatch losses. T.mp.retur.coefficient of Pm. Y 9,`C -0.45 Grounding holes a a Temperature coefficient of Voc Be., %/'C -0.37 2-e0 236(6) • . o d a QUALITY & RELIABILITY T mp.rab..coefficient of 1. aw %PC 0.06 g1 -Robust,corrosion resistant aluminum frame independently tested -- I j to withstand wind and snow loads of up to 50 psf and 113 psf, OPERATING CONDITIONS Mounting holes respectively,ensuring a stable mechanical life. __ 4-0.256x0 315 Max.system ''voltage 600Voc (6.68) -Manufacturing facility certified to IS09001 Quality Management Max.series fuse rating 15A -. System standards. Drainageholes r;,fi Operating temperature range -40 to 194°F(-40 to 90°C) „g_ 8-00.157(4) .;a A A Module packaging optimized toprotectproduct during s ' rs { P 9 9 P g Max.static load,from(e.g.,snow and wind) �' 113 psf(5400 Pa) ,eta a 1 transportation and minimize on-site waste. Max.static load,back(e.g.,wind) 50 psf(2400 Pa) 0.47(12) -,'`. .n' WARRANTIES Hailstone impact f 111(25 mm)at 51 mph(23 m/s) -Extensive 5-year limited product warranty and a 25-year limited power /'' \ SILVER FRAME BLACK FRAME warranty. CONSTRUCTION MATERIALS ( g 1l * Front cover(material/typehhickness) Low-iron glass/tempered/3.2 mm I SECTION A-A r -Limited power warranty =90%of the minimum rated power output / for 10 years,80%of the minimum rated power output for 25 years. cell(quantity/material/type/dimensions/area)sees) 60/polysilicon/multic multicrystalline \ 156 mm x 156 mm/243.3 cm' *In compliance with our warranty terms and conditions. Encapsulant(material) Ethylene vinyl acetate(EVA) �P�„ Frame(material/color) Aluminum alloy/anodized silver or black ',„. QUALIFICATIONS & CERTIFICATES Junction box(protection degree) IP65 // \\ Wanting:Read the Installation and Use Manual in its entirety * UL 1703 and ULC 1703,UL Fire Safety Class C,CEC,FSEC,ISO 9001:2008, Cable(type/length/gauge/outside diameter) PV Wire/47.24 in(1200 mm)/12 AWG/0.244 in(6.2 mm) / 1 before handling,installing,and operating Yingli modules. ISO 14001:2004,BS OSHAS 18001:2007,SA8000 Plug connector Amphenol/H4/IP68 (manufacturer/type/protection degree) I IIL DS Q Our Partners LILTED ar m •The spedfications in this datesheet are not guaranteed and are subject to change without prior notice. 1P1,0".01-1 7.MOD,'.0 unD Yingli Green Energy Americas,Inc. info@yingliamericas.com Tel:+1 (888)686-8820s 4,YINGLI SOLAR YINGLISOLAR.COM I NYSE:YGE ,,L. YINGLISOLAR.COM Yingli Americas "` °-- *Yingli Green Energy Holding Co.Ltd. I YGE2405edes_EN_201107_v01 Yeti with Eco-Fasten GreenFasten Flashing Yeti with Eco-Fasten GreenFasten Flashing , . The SolarCity Yeti with Eco-Fasten GreenFasten flashing optimizes strength,performance and aesthetics while structurally attaching solar panels to composition shingle roofs. This engineered connection uses 0.378T1IRUALL Eco-Fasten's patented, IAPMO-certified"green fasten"technology to achieve a watertight seal. 6000 cou°.RR°NK series aluminum offers superb structural and fatigue strength,which in conjunction with anodization offers excellent corrosion resistance even in coastal environments. 1410. 1.92 ■ • IAPMO-ES-certified for waterproofing–Tested to ICC ac286 — I' • Tested in accordance with UL 441–Waterproofing for rooftop penetrationsiiiL '411111 • Anodized for long term corrosion resistance and best aesthetics 2.53 • No shingle cutting required • Fast and error-proof installation reduces overall impact on roof 3.75 • Compatible with SolarCity Canopy Rail • Rail is attached using Stainless Steel Fasteners .380:.010 Components Installation Instructions L .,i A. 5/16"Lag Screw 1. Drill pilot hole in rafter B. Stainless Steel+EPDM Sealing Washer 2. Seal pilot hole with roofing sealant 1.94 C. Yeti(L-foot) 3. Insert Eco-Fasten flashing under upper layer of D. Eco-Fasten GreenFasten Flashing shingle 3.00 4. Place SolarCity Yeti 5. Install lag with sealing washer I( I A lr J . op B C t:''''''.-----'''' 111111111111111111%11111"11111% - -7 '' ' 1 11 i 8q w 440.. -',. SolarCity --. SolarCity