Report /4SP.2-0 - Ck.
CSI)? 5w � •
Page 1 C:\Userb\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1467\1467-279-BEAMS\1467-279-BEAM J.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 02/23/13 09:51:51
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1467-279-BEAM J
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 0.000' 10.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 4042 4557 4035 0.054 0.077
ALLOWABLE 9188 18187 7897 0.307 0.460
STRESS INDICES 0.440 0.251 0.511 L/2029 L/1436
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** CONTACT HANGER MANUFACTURER TO VERIFY ABILITY OF HANGER TO DISTRIBUTE LOAD
*** CONCENTRATED SIDE LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
THIS CONNECTION AND RESTRAINT OF THE TORSION INDUCED BY THE SIDE
LOAD ON THE MEMBER ARE THE RESPONSIBILITY OF THE PROJECT DESIGNER.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
9.500'
TOTAL SPAN: 9.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 Xl (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 78.8 PLF 0.000 9.500
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 9.500
ALL 1 *CONC DEAD FLOOR SIDE 796.9 LBS 1.000
+1 1 *UNIF LIVE FLOOR SIDE 210.0 PLF 0.000 9.500
1 1 *CONC LIVE FLOOR SIDE 2125.1 LBS 1.000
Page 2 1467-279-BEAM J.dsn
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 9.500
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 1.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 4557 4035 1.00
2 1331 1140 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 4042 1736
2 1144 514
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1144 514
2 1144 514
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2899 1221
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 796.9 1.000 3.500
1 LIVE 2125.1 1.000 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.054 0.307 L/2029 0.077 0.460 L/1436
2 1 0.000 0.307 0.022 0.460 L/4912 0.022 0.034
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.251 0.511
2 0.081 0.160
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1467\1467-279-BEAMS\1467-279-BEAM K.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 02/23/13 10:01:35
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1467-279-BEAM K
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2650Fb-1.9E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 9.000' 16.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 2623 4543 2521 0.033 0.046
ALLOWABLE 9187 18187 7897 0.240 0.360
STRESS INDICES 0.285 0.250 0.319 L/2641 L/1888
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
6" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
7.500'
TOTAL SPAN: 7.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 Xl (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 187.5 PLF 0.000 7.500
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 7.500
+1 1 *UNIF LIVE FLOOR SIDE 500.0 PLF 0.000 7.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 7.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 4543 2521 1.00
Page 2 1467-279-BEAM R.dsn
2 1295 719 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 2623 2623
2 748 748
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 748 748
2 748 748
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1875 1875
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.033 0.240 L/2641 0.046 0.360 L/1888
2 1 0.000 0.240 0.013 0.360 L/6624 0.013 0.020
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.250 0.319
2 0.079 0.101
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\User's\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\JOB 1467\1467-279-BEAMS\1467-279-BEAM L.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.1 02/23/13 10:08:16
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.1 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 1467-279-BEAM L
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 1.000' 1.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 5128 20298 5088 0.316 0.447
ALLOWABLE 13781 30368 12053 0.482 0.723
STRESS INDICES 0.372 0.668 0.422 L/548 L/388
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONTACT HANGER MANUFACTURER TO VERIFY ABILITY OF HANGER TO DISTRIBUTE LOAD
*** CONCENTRATED SIDE LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
THIS CONNECTION AND RESTRAINT OF THE TORSION INDUCED BY THE SIDE
LOAD ON THE MEMBER ARE THE RESPONSIBILITY OF THE PROJECT DESIGNER.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
14.750'
TOTAL SPAN: 14.75 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING WI W2 Xl (FT) X2 (FT)
+ALL 1 UNIF WEIGHT BEAM 17.8 PLF 0.000 14.750
+ALL 1 UNIF DEAD FLOOR TOP 15.0 PLF 0.000 14.750
ALL 1 *CONC DEAD FLOOR SIDE 1102.4 LBS 4.000
ALL 1 *CONC DEAD FLOOR SIDE 715.4 LBS 5.500
Page 2 5.467-279-BEAM L.dsn
+1 1 UNIF LIVE FLOOR TOP 40.0 PLF 0.000 14.750
1 1 *CONC LIVE FLOOR SIDE 2939.6 LBS 4.000
1 1 *CONC LIVE FLOOR SIDE 1907.6 LBS 5.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 14.750
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 4.000
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 5.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 20298 5088 1.00
2 5854 1482 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 5128 2611
2 1494 808
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1494 808
2 1494 808
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 3634 1804
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
CONCENTRATED LOADS
SPAN TYPE W1 (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 1102.4 4.000 3.500
1 DEAD 715.4 5.500 3.500
1 LIVE 2939.6 4.000 3.500
1 LIVE 1907.6 5.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.316 0.482 L/548 0.447 0.723 L/388
2 1 0.000 0.482 0.130 0.723 L/1330 0.130 0.196
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.668 0.422
2 0.214 0.137
SLENDERNESS RATIO = 2.26 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
Page 3 1467-279-BEAM L.dsn
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS