Loading...
Report (32) 2013.4 Allowable Stress Design , MSI: A.79 NOTE: LOAD TABLE 1 LPI 20PIus DEPTH 11.875" I DESIGN CRITERIA VSI: 0.70 1.THIS COMPONENT IS DESIGNED TO SUPPORT ONLY r WEB: 0.375" J RSI: 0.85 THE VERTICALLOADS SHOWN VERIFICATION OF NOTE: LOADS SHOWN ARE FOR INPUT LOAD CASE(1). OTHER LOAC)CASE FLANGE 1.50 X 2.50 LOADING,DEFLECTION LIMITATIONS,FRAMING FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIREI - LIVE LOAD = 40 PSF METHODS,WIND AND SEISMIC BRACING,AND OTHER (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER DEAD LOAD = 12 PSF LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION SOURCE TYPE TOP/SIDE LOAD FROM TO LOAD LDF TOTAL LOAD = 52 PSF THE RESPONSIBILITY OF THE PROJECT ENGINEER FT-IN-SX FT-IN-SX OR ARCHITECT. UNIFORM FLOOR LIVE TOP 80 PLF 00-00-00 30-00-00 1.00 I SPACING = 24.00 IN. C/C 2.PROVIDE RESTRAINT AT SUPPORTSTO ENSURE UNIFORM FLOOR DEAD TOP 24 PLF 00-00-00 30-00-00 0.90 LATERAL STABIUTY DEFLECTION CRITERIA : 3.DO NOT CUT,NOTCH OR DRILL LPI FLANGES. WARNING NOTES: LIVE LOAD DEFL: L / 480 4.SHIM ALL BEARINGS FOR FULL CONTACT. TOTAL LOAD DEFL: L / 360 5.VERIFY DIMENSIONS BEFORE CUTTING LPI TO SIZE. THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. 6.THIS LPI IS TO BE USED AS AFLOOR JOIST ONLY USE OF THIS DESIGN FOR ANYTHING OTHER THAN LP LVL OR LP LSL OR LP I-JOISTS IS CODE COMPLIANCES : 7.COMPRESSION EDGE BRACING REQUIRED AT STRICTLY PROHIBITED.ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW REPORT # 59'O.C.OR LESS. BY A DESIGN PROFESSIONAL. - APA PR-L238 ICC-ES ESR-1305 . MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LPI LADBS RR-25099 JOIST AS DESIGNED.IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, CCMC 12412-R ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS Florida FL15401 JOIST IS CAPABLE OF SUPPORTING THE REACTIONS. PROVIDE ANCHORAGE FOR UPLIFT AT SUPPORTS.ANCHORAGE DETAIL TO BE PROVIDED BY PROJECT DESIGNER. ANCHOR LPI JOIST SECURELY TO BEARINGS OR HANGERS. DEFLECTION ASSUMES COMPOSITE ACTION WITH GLUED AND APPLIED LOADS OVER END BEARINGS AND LOADS EXCEEDING 250 LBS OVER NAILED 23/32" APA RATED INTERMEDIATE BEARINGS MUST BE TRANSFERED DIRECTLY TO SUPPORT BY SHEATHING (48/24 SPAN RATING) RIM BOARD,BLOCKINGS,SQUASH BLOCKS OR OTHER DEVICE. IVibration ControlledSpansAssume: I Concrete strength: None Concrete thickness: 0 Sheathing Material: 23/32" Ceiling Material: None Ceiling Straps 24"o.c. None None Bridging Material: None Number of Rows: 11.875I. J SUPPORT REACTIONS (LBS): MAXIMUM BEARING NUMBER 1 2 3 2.500 csi DOWN 565 1978 746 UPLIFT 24 --- --- CROSS SECTION MIN BEARING SIZES (IN-SX) 4- 8 3- 8 4- 8 MAXIMUM DEFLECTIONS CALCULATED ALLOFIP.BLE LIVE LOAD 0.27"(L/730) 0.42" \ 13- 0- 0 \ 17- 0- 0 \ *DEAD LOAD 0.11" \ - - - 30- 0- 0 \ TOTAL LOAD 0.34"(L/586) 0.56" ***THIS DRAWING IS NOT TO SCALE*** Handling&Erection Miscellaneous Information LP LVL,LP LSL and CTR,LP I-Joist Specifications Software Provided By: 04/04/14 IBC 2009 Temporary and permanent bracing for holding component The use of this component shall be specified by the designer of the *Supports and connections for LP LVL,LP LSL,CTR and LPI to be specific applicatio LP Engineered Wood Products plumb and for resisting lateral forces shall be designed and complete structure.Obtain all the necessary code compliance *Common nails driven parallel to glue lines shall be spaced a minimum of 4"for 10d 414 Union Street,Suite 2000 installed by others. No loads are to be applied to the approval and instructions from the designers of the complete structure and 3"for 8d. Nashville,TN 37219 component until after all the framing and fastening are before using this component. If the design criteria listed above does •Do not cut,notch,drill or alter LP LVL,LP LSL and CTR,LP I-Joists except as shown completed.At no time shall loads greater than design not meet local building code requirements,do not use this design. in published material from LP any use of LP LVL,LSL and CTR,LP I-Joists contrary Phone 800.515.7570 loads be applied to the component. When this drawing is signed and sealed,the structural design is to the limits set forth hereon,negates any express warranty of the product and LP Fax 866.753.4369 approved as shown in this drawing based on data provided by the disclaims all implied warranties including the implied warranties of merchantability Design Criteria customer. LP LVL,LP LSL and CTR,LP I-joists are made without and fitness for a particular use. The design and material specified are in substantial camber and will deflect under load.Wood in direct contact with DWG # conformity with the latest revisions of NDS.•Dead load concrete must be protected as required by code.Continuous lateral deflection includes adjustment factor for creep.Total load support is assumed(wall,floor beam,etc.).LP does not provide •A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR SHEET # deflection is instantaneous. on-site inspection.This drawing must have an Architect's or Engineer's seal aaixed to be considered an Engineering document. LP is a registered trademark of Louisiana-Pacific Corporation. File:J:\IWP14268\WOODE.SPX 2013.4 Allowable Stress Design MSI:.0.14 NOTE: LOAD TABLE I 1 PLY 3.500 X 11.875 LP LSL 1.55E I DESIGN CRITERIA : ' vsI: 0.10 1.THIS COMPONENT IS DESIGNED TO SUPPORT"ONLY NOTE: LOADS SHOWN ARE FOR INPUT LOAD CASE(1). OTHER LOAD CASE r RSI: 0.19 - THEVERTICALLOADSSHOWNVERIFICATIONOF LOADING,DEFLECTION UMITATIONS,FRAMING FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRE' _ METHODS,WIND AND SEISMIC BRACING,AND OTHER (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER LIVE LOAD 40 PSF DEAD LOAD = 12 PSF LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION SOURCE TYPE TOP/SIDE LOAD FROM TO LOAD LDF TOTAL LOAD = 52 PSF THE RESPONSIBILITY OF THE PROJECT ENGINEER FT-IN-SX FT-IN-SX OR ARCHITECT. UNIFORM FLOOR LIVE TOP 600 PLF 00-00-00 05-00-00 1.00 2 PROVIDE RESTRAINT AT SUPPORTSTO ENSURE UNIFORM FLOOR DEAD TOP 180 PLF 00-00-00 05-00-00 0.90 FLR LEFT SPAN CARR. : 17.00 FT LATERAL STABILITY. UNIFORM BEAM WEIGHT 13 PLF 00-00-00 05-00-00 0.90 FLR RIGHT SPAN CARR. : 13.00 Fr 3.DO NOT CUT,NOTCH OR DRILL LP LSL. 4 SHIM ALLBEARINGS FOR FULL CONTACT. WARNING NOTES: DEFLECTION CRITERIA : 5.VERIFY DIMENSIONS BEFORE CUTTING LP LSL LIVE LOAD DEFL: L / 480 TO SIZE. THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. TOTAL LOAD DEFL: L / 360 6.THIS LP LSLIS TO BE USED ASA FLOOR BEAM ONLY. USE OF THIS DESIGN FOR ANYTHING OTHER THAN LP LVL OR LP LSL OR LP I-JOISTS IS 7.COMPRESSION EDGE BRACING REQUIRED AT STRICTLY PROHIBITED.ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW CODE COMPLIANCES : EACH END OF COMPONENT. BY A DESIGN PROFESSIONAL. REPORT # APA PR-L280 MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LP LSL ICC-ES ESR-2403 BEAM AS DESIGNED.IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, LADBS RR-25783 ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS CCM 13319-R BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. Florida FL15228 ANCHOR LP LSL FLOOR BEAM SECURELY TO BEARINGS OR HANGERS. 1 • 11.8751.,. J SUPPORT REACTIONS (LBS): MAXIMUM BEARING NUMBER �c 1 2 I — 3.500 DOWN 1983 1983 UPLIFT --- --- CROSS SECTION MIN BEARING SIZES (IN—SX) 3— 8 3— 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0.01"(L/3840) 0.12" *DEAD LOAD 0.01" \ 5— 0— 0 \ TOTAL LOAD 0.02"(L/2904) 0.16" •••THIS DRAWING IS NOT TO SCALE••* Harxling&Erection Miscellaneous Information LP LVL,LP LSL and CTR,LP I-Joist Specifications Software Provided By: 04/04/14 IBC 2009 Temporary and permanent bracing for holding component The use of this component shall be specified by the designer of the •Supports and connections for LP LVL,LP LSL,CTR and LPI to be specific applicatio LP Engineered Wood Products plumb and for resisting lateral forces shall be designed and complete structure.Obtain all the necessary code compliance •Common nails driven parallel to glue lines shall be spaced a minimum of 4"for 10d 414 Union Street,Suite 2000 installed by others.No loads are to be applied to the approval and instructions from the designers of the complete structure and 3•for8d. Nashville,TN 37219 component until after all the framing and fastening are before using this component. If the design criteria listed above does •Do not cut,notch,drill or alter LP LVL,LP LSL and CTR,LP I-Joists except as shown completed.At no time shall loads greater than design not meet local building code requirements,do not use this design. in published material from LP any use of LP LVL,LSL and CTR,LP IJoists contrary Phone 800.515.7570 loads be applied to the component. When this drawing is signed and sealed,the structural design is to the limits set forth hereon,negates any express warranty of the product and LP Fax 866.753.4369 Design Criteria approved as shown in this drawing based on data provided by the disclaims all implied warranties including the implied warranties of merchantability customer. LP LVL,LP LSL and CTR,LP I-joists are made without and fitness for a particular use. The design and material specified am in substantial camber and will deflect under load.Wood in direct contact with DWG # conformity with the latest revisions of NDS.•Dead load concrete must be protected as required by code.Continuous lateral deflection includes adjustment factor for creep.Total load support is assumed(salt,floor beam,etc.).LP does not provide •ACOPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR SHEET # deflection is instantaneous. on-site inspection.This drawing must have an Architect's or Engineer's seal afixed to be considered an Engineering document. LP is a registered trademark of Louisiana-Pacific Corporation. File:J:\IWP14266\WOODE.SPX 2013.4 Allowable Stress Design . MSI: P.07 NOTE: LOAD TABLE I 1 PLY 1.750 X 11.875 LP LSL 1.55E I DESIGN CRITERIA VSI: 0.06 1.THIS COMPONENT IS DESIGNED TO SUPPORT'ONLY NOTE: LOADS SHOWN ARE FOR INPUT LOAD CASE(1). OTHER LOAD CASE RSI: 0.21 - LELOADING,VERTICAL DEFLECTIONOADS SHOWN IOVENS,FRAMINGAN OF FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRE( LIMITATIONS, (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER LIVE LOAD = 40 PSF METHODS,WIND AND SEISMIC BRACING,AND OTHER DEAD LOAD = 12 PSF LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION SOURCE TYPE TOP/SIDE LOAD FROM TO LOAD LDF TOTAL LOAD = 52 PSF THE RESPONSIBILITY OF THE PROJECT ENGINEER FT-IN-SX FT-IN-SX OR ARCHITECT. UNIFORM FLOOR LIVE TOP 112 PLF 00-00-00 03-11-08 1.00 2.PROVIDE RESTRAINTAT SUPPORTSTO ENSURE UNIFORM FLOOR DEAD TOP 34 PLF 00-00-00 03-11-08 0.90 FLR LEFT SPAN CARR. : 1.58 FT LATERAL STABILITY. UNIFORM BEAM WEIGHT 7 PLF 00-00-00 03-11-08 0.90 FLR RIGHT SPAN CARR. : 4.00 FT 3.DO NOT CUT,NOTCH OR DRILL LP LSL. CONCENTRATED FLOOR LIVE TOP 262 LBS 00-00-05MINBRG=3.00" 1.00 4.SHIM ALLBEARINGS FOR FULL CONTACT. CONCENTRATED FLOOR DEAD TOP 78 LBS 00—00-05MINBRG=3.00" 0.90 DEFLECTION CRITERIA : 5.VERIFY DIMENSIONS BEFORE CUTTING LP LSL CONCENTRATED FLOOR LIVE TOP 262 LBS 01-10-12MINBRG=3.00" 1.00 LIVE LOAD DEFL: L / 480 TO SIZE. CONCENTRATED FLOOR DEAD TOP 78 LBS 01-10-12MINBRG=3.00" 0.90 TOTAL LOAD DEFL: L / 360 6.THIS LP LSLIS TO BE USED ASA FLOOR BEAM ONLY CONCENTRATED FLOOR LIVE TOP 262 LBS 03-11-04MINBRG=3.00" 1.00 7.COMPRESSION EDGE BRACING REQUIRED AT CONCENTRATED FLOOR DEAD TOP 78 LBS 03-11—04MINBRG=3.00" 0.90 CODE COMPLIANCES : EACH END OF COMPONENT. REPORT # WARNING NOTES: APA PR-L280 ICC-ES ESR-2403 THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. LADBS RR-25783 USE OF THIS DESIGN FOR ANYTHING OTHER THAN LP LVL OR LP LSL OR LP IJOISTS IS CCMC 13319-R STRICTLY PROHIBITED.ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW Florida FL15228 BY A DESIGN PROFESSIONAL. PROVIDE RESTRAINT AT CONCENTRATED LOAD TO ENSURE LATERAL STABILITY. MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LP LSL BEAM AS DESIGNED.IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. ANCHOR LP LSL FLOOR BEAM SECURELY TO BEARINGS OR HANGERS. lc- 11.875L J SUPPORT REACTIONS (LBS): MAXIMUM BEARING NUMBER 1 2 ir 50 DOWN 817 804 UPLIFT --- --- CROSS SECTION MIN BEARING SIZES (IN—SX) 2— 8 2— 8 MAXIMUM DEFLECTIONS CALCULATED ALLOVABLE LIVE LOAD 0.01"(L/7817) 0.09" *DEAD LOAD 0.00" \- 3-11— 8 ‘ TOTAL LOAD 0.01"(L/5886) 0.13" *••THIS DRAWING IS NOT TO SCALE*** Handing 8 Erection Miscellaneous Information LP LVL,LP LSL and CTR,LP I-Joist Specifications Software Provided By: 04/07/14 IBC 2009 Temporary and permanent bracing for holding component The use of this component shall be specified by the designer of the •Supports and connections for LP LVL,LP LSL,CTR and LPI to be specific applicatio LP Engineered Wood Products plumb and for resisting lateral forces shall be designed and complete structure.Obtain all the necessary code compliance •Common nails driven parallel to glue lines shall be spaced a minimum of 4"for 10d 414 Union Street,Suite2000 installed by others.No loads are to be applied to the approval and instructions from the designers of the complete structure and 3"for 8d. Nashville,TN 37219 component until after all the framing and fastening are before using this component. If the design criteria listed above does 'Do not cut,notch,drill or alter LP LVL,LP LSL and CTR,LP(Joists except as shown completed.At no time shall loads greater than design not meet local building code requirements,do not use this design. in published material from LP any use of LP LVL,LSL and CTR,LP I-Joists contrary Phone 800.515.7570 loads be applied to the component. When this drawing is signed and sealed,the structural design is to the limits set forth hereon,negates any express warranty of the product and LP Fax 866.753.4369 approved as shown in this drawing based on data provided by the disclaims all implied warranties including the implied warranties of merchantability Design Criteria customer. LP LVL,LP LSL and CTR,LP 1-joists are made without and fitness for a particular use. The design and material specified are in substantial camber and will deflect under load.Wood in direct contact with DWG # conformity with the latest revisions of NDS.•Dead load concrete must be protected as required by code.Continuous lateral deflection includes adjustment factor for creep.Total load support is assumed(wall,floor beam,etc.).LP does not provide "ACOPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR SHEET # deflection is instantaneous. on-site inspection.This drawing must have an Architect's or Engineers seal afixed to be considered an Engineering document. LP is a registered trademark of Louisiana-Pacific Corporation. File:J:\I WP14268\WOODE.SPX 2013.4 Allowable Stress Design kISI: .11 NOTE LOAD TABLE 1 PLY 1.750 X 11.875 LP LSL 1.55E � DESIGN CRITERIA : VSI:0.13 1.THIS COMPONENT IS DESIGNED TO SUPPORT'ONLY • NOTE: LOADS SHOWN ARE FOR INPUT LOAD CASE(1). OTHER LOAM CASE ' RSI: 0.13 THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING,DEFLECTION LIMITATIONS,FRAMING FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRE! LIVE LOAD = 40 PSF METHODS,WIND AND SEISMIC BRACING,AND OTHER (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER = DEAD LOAD12 PSF LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION SOURCE TYPE TOP/SIDE LOAD FROM TO LOAD LDF TOTAL LOAD = 52 PSF THE RESPONSIBILITY OF THE PROJECT ENGINEER FT-IN-SX FT-IN-SX _ OR ARCHITECT. UNIFORM FLOOR LIVE TOP 80 PLF 00-00-00 06-01-00 1.00 2.PROVIDE RESTRAINT AT SUPPORTSTO ENSURE UNIFORM FLOOR DEAD TOP 24 PLF 00-00-00 06-01-00 0.90 FIR LEFT SPAN CARR. : 2.00 FT LATERAL STABILITY. UNIFORM BEAM WEIGHT 7 PLF 00-00-00 06-01-00 0.90 FIR RIGHT SPAN CARR. : 2.00 FT a DO NOT CUT,NOTCH OR DRILL LPLSL. CONCENTRATED FLOOR LIVE TOP 566 LBS 01-03—OOMINBRG=3.00" 1.00 4.SHIM ALLBEARINGS FOR FULL CONTACT. CONCENTRATED FLOOR DEAD TOP 170 LBS 01-03—OOMINBRG=3.00" 0.90 DEFLECTION CRITERIA : '.. 5.VERIFY DIMENSIONS BEFORE CUTTING LP LSL LIVE LOAD DEFL: L / 480 TO SIZE. WARNING NOTES: TOTAL LOAD DEFL: L / 360 6.THIS LP LSLIS TO BE USED ASA FLOOR BEAM ONLY. 7.COMPRESSION EDGE BRACING REQUIRED AT THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. CODE COMPLIANCES : EACH END OF COMPONENT. USE OF THIS DESIGN FOR ANYTHING OTHER THAN LP LVL OR LP LSL OR LP I-JOISTS IS REPORT # STRICTLY PROHIBITED.ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW APA PR-L280 BY A DESIGN PROFESSIONAL. ICC-ES ESR-2403 1 LADBS RR-25783 PROVIDE RESTRAINT AT CONCENTRATED LOAD TO ENSURE LATERAL STABILITY. CCMC 13319—R Florida FL15228 MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LP LSL BEAM AS DESIGNED.IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. I ANCHOR LP LSL FLOOR BEAM SECURELY TO BEARINGS OR HANGERS. 11.875L J SUPPORT REACTIONS (LBS): } ,XIMUM BEARING NUMBER 1 2 ir 1.750 DOWN 921 488 UPLIFT --- --- CROSS SECTION MIN REARING SIZES (IN—SX) 4— 8 4— 8 MAXIMUM DEFLECTIONS CALCULATED ALLOMBLE LIVE LOAD 0.02"(L/4533) 0.14" *DEAD LOAD 0.01" N. 6— 1— 0 N. TOTAL LOAD 0.02"(L/3384) 0.19" •••THIS DRAWING IS NOT TO SCALE*** Handling&Erection Miscellaneous Information LPLVL,LPLSL and CTR,LPI-Joist Specifications Software Provided By: 04f07/14 IBC 2009 Temporary and permanent bracing for holding component The use of this component shall be specified by the designer of the •Supports and connections for LP LVL,LP LSL,CTR and LPI to be specific applicatio LP Engineered Wood Products plumb and for resisting lateral forces shall be designed and complete structure.Obtain all the necessary code compliance •Common nails driven parallel to glue lines shall be spaced a minimum of 4"for 104 414 Union Street,Suite 2000 installed by others. No loads am to be applied to the approval and instructions from the designers of the complete structure and 3"for 8d. Nashville,TN 37219 component until after all the framing and fastening are before using this component. If the design criteria listed above does •Do not cut,notch,drill or alter LP LVL,LP LSL and CTR,LP I-Joists except as shown completed.At no time shall loads greater than design not meet local building code requirements,do not use this design. in published material from LP any use of LP LVL,LSL and CTR,LP I-Joists contrary Phare 800.515.7570 loads be applied to the component. When this drawing is signed and sealed,the structural design is to the limits set forth hereon,negates any express warranty of the product and LP Fax 866.753.4369 approved as shown in this drawing based on data provided by the disclaims all implied warranties including the implied warranties of merchantability Design Criteria customer. LP LVL,LP LSL and CTR,LP Hoists are made without and fitness for a particular use. The design and material specified are in substantial camber and will deflect under load.Wood in direct contact with DWG # confornity with the latest revisions of NDS."Dead load concrete must be protected as required by code.Continuous lateral deflection includes adjustment factor forcreep.Total load support is assumed(wall,floor beam,etc.).LP does not provide *A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR SHEET # deflection is instantaneous. on-site inspection.This drawing must have an Architect's or Engineer's seal affixed to be considered an Engineering document. LP is a registered trademark of Louisiana-Pacific Corporation. File:J:\IWP14268\WOODE.SPX . Rosboro Client PARR LUMBER Shipping ROCKWOOD Project Name: CROSS PAR11BETTERTIOHONM2ES Job#: IWP14268 Quantity 1 Description: EVEN B4 Rosboro Big Beam 7.000" X 14.000" - PASSED 4/8/2014 47 PM Page 1 of; Designer:Sean McCartney itilili iiiijttiMjijillittiniliiiii11,11111n11111tifiliti .lijilr 1,1, Jji t ll,l,li1Jriflc; ltiijjIiJ11Ij( Iftl,' ( ... } lI�ILLI�� �.t11, 1 1 111 i � 11' '1 1- , i ( 1 - ( Alli 1 { 1 ° . _, 1190bi ro Rf.boro / 1 SPF 2 SPF 8'8" r7" $,$„ Type: Girder Application: Floor Reactions Moisture Condition:Dry Design Method: ASD Brg Live Dead Snow Wind Const Deflection LL: 480 Building Code: IBC 2012/IRC 1 6382 3539 0 0 0 Deflection TL: 360 Load Sharing: No Importance: Normal Wet Use: No 2 4747 3556 0 0 0 Temperature: Temp<=100°F Deck: 3/4"SPF Plywood Nailed Vibration: Not Checked Bearings Bearing Input In Cap. React D/L lb Total Ld.Case Ld.Comb. Analysis Actual Location Allowed Capacity Load Comb.Ld.Case Length Analysis Moment 15764 ft-lb 47 13/16" 56751 ft-lb 0.278(28%) D+L L 1-SPF 5.500" 3.500" 95% 3539/6382 9921 L D+L Shear 6336 lb 1'5 3/4" 19600 lb 0.323(32%) D+L L 2-SPF 5.500" 3.000" 93% 3556/4747 8303 L D+L LL Defl inch 0.032(L/3028) 4'3 5/16" 0.201(U480) 0.160(16%) L L TL Defl inch 0.054(U1771) 4'3 9/16" 0.267(U360) 0.200(20%) D+L L Design OK. Design Notes 1 Girders are designed to be supported on the bottom edge only. 2 Bottom unbraced. ID Load Type Location Trib Width Side Dead Live Snow Wind Const. Comments 1 Tie-In 0-0-0 to 8-8-0 (Span)30-0-0 Top 25 PSF 40 PSF 0 PSF 0 PSF 0 PSF TOP FLR SC 2 Tie-In 0-0-0 to 8-8-0 (Span)10-2-0 Top 12 PSF 40 PSF 0 PSF 0 PSF 0 PSF LSC 3 Tie-In 0-0-0 to 8-8-0 (Span)10-0-0 Top 54 PSF 50 PSF 0 PSF 0 PSF 0 PSF RSC-GARAGE 4 Uniform Top 90 PLF 0 PLF 0 PLF 0 PLF 0 PLF WALL 5 Point 1-0-0 Top 0 lb 2000 lb 0 lb 0 lb 0 lb CAR Self Weight 25 PLF International Wood Products 14421 SE 98th Ct.,OR 97015 IIvjI. intern:= iW odrmduas,we Powered by c3 iStruct 13.6.096 f(ALtIA/1TED ST0.lKTU 31 DESIGNS