Permit (21) CITY OF TIGARD111 MECHANICAL PERMIT 1 ' COMMUNITY DEVELOPMENT Permit#: MEC2016-00190 T tGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/19/2016 Parcel: 1 S 1260000300 Jurisdiction: Tigard Site address: 9312 SW WASHINGTON SQUARE RD WO1 Project: Kay Jewelers Subdivision: None Lot: None Project Description: Mechanical for T.I. New duct work,diffusers,grilles,dampers,transfer air,and new chilled water system. Contractor: METALAIR LLC Owner: PPR WASHINGTON SQUARE LLC 7350 NEW HOPE RD PO BOX 847 GRANTS PASS, OR 97527 CARLSBAD,CA 92018 PHONE: 702-768-0209 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 07/19/2016 $881.11 Class of Work: ALT Type of Const: IIB Plan Review 07/19/2016 $220.28 Occupancy Grp: M Occupancy Load: 12%State Surcharge-Mechanical 07/19/2016 $105.73 Stories: 1 Project Valuation: $31,000.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: 1 Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: Appliances Vent Fans: 1 Vent Systems: Total $1,207.12 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 2 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or dire .uestion 0.. 1 sy calling 503.232.1987 or 1.800.332.2344. Is- ed By: , 0 , Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. .,—„-cc, ,,-,-4,'V , • ' Mechanical Permit Applica ' � FOR OFFICE USE OivLV City of Tigard Received • l 9 p }� �� gI i r `J g ) a Date/By: ) !adj /i // Permit No.: ` �a3 1 V,�pl 7 c, II 9 13125 SW Hall Blvd.,Tigard,OR 07223 (N,'\, II Plan Rem /f / C Phone: 503.7182439 Fax: 503.598.1960 y DateB : . P et Other Permit: 8� f{U (A 3 y II G A R I� Inspection Line: 503.639.4175 i I „'a2,,',) Date Ready:y: Iuris: ® See Page 2 for Internet: www.tigard-or.gov 4.t. ), Notified/Metbod /3/,/„ 4 y� Supplemental Information Pe `1,, '-,u,„,-,,,,` - - t19] d° �1 ,.@ eS .�. R ^ G.8.P FL g tT I oI L - - ' '-4.,t„ ' " Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead and profit. Value:$ s r ❑1-and 2-family dwelling ®Commercial/industrial 0 Accessory building Far special information use checklist. O Multi-family 0 Master builder 0 Other: Description I Qty. I Ea. I Total I(ni ;H€i_ ' ��1VA '€5�©ats�'BI � _-_3 ' Heating/cooling: - .- '` ' --- Air conditioning 1 46.75 Job site addres r!. Washing Square RoadL Furnace 100,000 BTU(ducts/vents) 46.75 w , City/State/ZIP:Po> a rt OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.:WO! l Project name:Kay Jewelers Duct work 2 23.32 Cross street/directions to job site:SW Washington Square Rd Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 M Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 2 Flue/vent for any of above 23.32 Lot no.: Other:chilled water 1 23.32 Subdivision: I Other fuel appliances: •meq, Tax map/parcel no.: Water heater 1 23.32 Gas fireplace/insert 3339 Flue vent for water heater or gas Remodle of existing Kay Jewelers store. Install new chilled water AHD fi'pl: - 23.32 Connecting to Landlord chilled water system and outdoor air Lo fighter(gas) 23.32 ood/pellet stove 33.39 Installing new ductwork,diffusers,grilles,dampers,transfer air Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 2 - - Other: 23.32 d . _ -_� - ----- Environmental exhaust and ventilation: Name:Signet Jewelers Range hood/other kitchen equipment 33.39 Address:375 Ghent Road Clothes dryer exhaust 33.39 City/State/ZIP:Akron,OH 44333 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 1 23.32 Phone:(330)665.6304 Fax:( ) Attic/crawlspace fans 23.32 1--..,E..I 3r:rf E 1, - i-AIH w4 < - . Other: 23.32 Fuel piping: Business name:State Permits $14.15 for first four;$4.03 for each additional Contact.name:Katie Getz Furnace,etc. Address:319 Elaine's Court Gas heat pump Wall/suspended/unit heater City/State/ZIP:Dodgeville,WI 53533 Water heater .--"-, Phone:(608)407.9078 I Fax::(608)319.2011 Fireplace Range E-mail:katie®permit.eom Barbecue rsi :u cNO), - Clothes dryer(gas) Business name: 7120 A CTA-L, 2 LI-C---- Other. Address: '7 36D Nt W I-1013er_ i2 Subtotal City/State/ZIP: -C, ts �Z4 7501-7 Minimum permit fee($90.00) �s JeA„re, Plan review(25%of permit fee) Phone:VVa) `7 tt g"b ..c:Y9 Fax:( ) State surcharge(12%of permit fee) CCB lie.: t q 4 p p 5`-) 1b2.-116, TOTAL PERMIT FEE , This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: -7--- . Fee methodology set by Tri-County Building Industry Service Board Print name:Todd Peterson Date:3/14/16 I:\Building\Permits\MEC PermitApp 040113.doc 440-46177(11/02/COM/WEB) Letter of Transmittal t S L STATE PERMITS,INC. a t9.Iva x2 saw, 319 Elaines Ct. -Dodgeville,WI 53533 608/319-2096 * fax: 608/319-2011 www.st8.com Date: 3/17/2016 To: City of Tigard Community Development/ City of Tigard 13125 S W Ha11 Blvd Tigard, OR 97223 Phone: (503) 639-4171 Attn: Dan Nelson Re: Kay Jewelers #0781 WASHINGTON SQUARE 9585 S Washington Sq Rd Tigard, OR Proj: 730588 We Transmit-VIA FED-EX -Application -Plans - Specs Check#23717 Amount$1,013.32 Payable To: City fo Tigard - Plan Review ITEMS : - 3 sets of plans - 3 sets of energy calcs - 3 sets of mech. calcs - 1 BPA - 1 Electrical App - 1 Mechanical App - 1 check for fees These Are Transmitted : - For Permit Remarks : Signed: Katie Getz x9078 Page 1 of 1 319 Elaines Ct.-Dodgeville,WI 53533 - 608/319-2096-Fax:608/319-2011 -www.st8.com Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 9312 SW WASHINGTON SQUARE RD W01, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2016-00190 Jeff Grove Violation Summary: Inspector Contractor