Loading...
Report (10) 10 BUP2005-00289 10775 SW CANTERBURY LN 11 BUP2005-00291 10769 SW CANTERBURY LN 12 BUP2005-00292 10765 SW CANTERBURY LN 7 ----- 16 BUP2005-00293 10739 SW CANTERBURY LN 17 BUP2005-00295 10731 SW CANTERBURY LN //i�m��Ai 18 BUP2005-00301 10783 SW CANTERBURY LN ��'9V�_ Janu 20, 2006 '.. °,„,..- January BUP2005-00299 10715 SW CANTERBURY LN 26 BUP2005-00284 10797 SW CANTERBURY LN CITY OF TIGARD JND Fire Sprinkler INC 27 BUP2005-00286 10793 SW CANTERBURY LN OREGON Jeff Dutton 28 BUP2005-00287 10789 SW CANTERBURY LN 12155 SW Grant Ave. Suite D Tigard, OR 97223 RE: FIRE SPRINKLER SYSTEM-NFPA 13R SYSTEM REVIEW Project Information Building Permit: Varies Buildings: 10-12,16-19,26-28 Occupancy Type: R1 Area: 2 Story 7,748 Sq Ft Address: Varies Construction Type: VN- Sprinklered Tenant Name: Canterbury Crest Hazard: Ordinary Group I The plan review was performed under the State of Oregon Structural Specialty Code(OSSC) 2004 edition,Oregon Fire Code 2004 edition; and NFPA 13. The following information is required in order to complete the review. 1. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. OSSC 106.3.4.2 2. The submitted plans are incomplete,the following list indicates what is required on plans, the ** indicates what is not shown on the plans: NFPA 13 R 6.1 6.1.7 Sprinkler plans shall indicate the following: (1)The name of owner and occupant (2)The location, including street address (3)The point of compass (4)The ceiling construction** (5)The full height cross section (6)The location of fire walls** (7)The location of partitions (8)The occupancy of each area or room (9)The location and size of concealed spaces, attics, closets, and bathrooms (10)Any small enclosures in which no sprinklers are to be installed (11)The size of the city main in the street,pressure, whether dead-end or circulating and, if dead-end,the direction and distance to the nearest circulating main, and the city 13125 SW Hall Blvd., Tigard, OR 97223 (503)639-4171 TDD(503)684-2772 • ' , t main test results including elevation of the test hydrant** (12)The make, manufacturer,type, heat-response element,temperature rating, and nominal orifice 'size of the sprinkler (13)The temperature rating and location of high-temperature sprinklers (14)The number of sprinklers on each riser, per floor** (15)The kind and location of alarm bells (16)The type of pipe and fittings (17)The type of protection for nonmetallic pipe** (18)*The nominal pipe size with lengths shown to scale (19)The location and size of riser nipples (20)The types of fittings and joints and the locations of all welds and bends (21)The types and locations of hangers, sleeves, and braces, and methods of securing sprinklers,where applicable** (22)All control valves, check valves, drain pipes, and test connections (23)The underground pipe size, length,location,weight,material, and point of connection to the city main; type of valves,meters, and valve pits; and depth at which the top of the pipe is laid below grade** (24)In the case of hydraulically designed systems,the material to be included on the hydraulic data nameplate (25)The name and address of the contractor Please provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard,Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectful) / . ...-/if' '' .c ,e_e/?" Val Henze), Senior Plans Examiner 10 BUP2005-00289 10775 SW CANTERBURY LN 11 BUP2005-00291 10769 SW CANTERBURY LN Fire Marshal's 12 BUP2005-00292 10765 SW CANTERBURY LN CLI \1 LI %� North Division-14480 SW Jenkins Rd.,Beaverton,OR 97016 BUP2005-00293 10739 SW CANTERBURY LN Tualatin Valley South Division-7401 SW Washo Ct.,Ste. 101,Tualatin,Of 17 BUP2005-00295 10731 SW CANTERBURY LN Fire & Rescue 18 BUP2005-00301 10783 SW CANTERBURY LN 19 BUP2005-00299 10715 SW CANTERBURY LN 26 BUP2005-00284 10797 SW CANTERBURY LN Building Survey Repoi27 BUP2005-00286 10793 SW CANTERBURY LN 28 BUP2005-00287 10789 SW CANTERBURY LN FMZ : (to be filled out by TVF&R) Code Edition: 98OSSC Name of Facility: Canterbury Woods Name of Building: 2 story Townhome Buildings 10-12, 16-19, 26-28 Address: SA Owner: Polygon Northwest Telephone No. (360) 695-7700 Architect: Leonard J. Milbrandt Telephone No. (425) 454-7130 Architect Address: .,E .3.;x ITEM . COMM AESCRIPTION Type R1 Use 4 unit condo Occupancyyp Capacity None 2. Construction Type V—N Year Built 3. Area(Sq.Ft.) Total 6878 Largest Floor 2 Basement None 4. Stories No 2 Height 26'-10" High Rise ❑Y ®N 5 a. Exterior Wall Construction WF-Non-rated b. Opening Protection None 6. Interior Wall Construction GB on WF/GB on WT 7. Floor Construction Carpet-Ply-WGL-GB 8. Roof Construction Class "C" RS-Roof Felt-Ply-WT @ 24" o.c. 9. Attic Draft Stops No. Yes-3 10a. Occ.Sep.Wall Construction No. Yes-3 GB-WF-Insulation-Airspace-WF-GB b. Opening Protection None t la. Fire Wall Construction No. None b. Opening Protection None 12a. Smoke Barrier Wall Construction No. None b. Opening Protection None 13a. Corridor Wall Construction None b. Opening Protection None 14a. Corridor Ceiling Construction None • b. Opening Protection None 15a. Shafts No. None Type b. Opening Protection None Building Survey Report FMZ : (to be filled out by TVF&R) Name of Facility: Canterbury Woods -HEM COMM DES( l'TION 16a. Stair Enclosure No. None Open stairway/None b. Opening Protection None 17. Stairs No. 4 18. Ramps No. None 19. Interior Finish Class Room None Exit Enclosure Corridor 20. Exits No. 4 Total WidthNone per 98OSSC 21. Exit Hardware Type Knob 22a. Exit Signs/Illumination None b. Emergency Lighting None 23. Auto Sprinkler Coverage Yes-P 24. Standpipe Class/Locations None 25. Fire Alarm Type/Coverage Yes- 26. Heating,Ventilation&Air Conditioning Type Unit Heat Fuel Electric 27. Electrical Installation Romex-Circuit breaker 28. Stage/Platform None 29. Hazardous Area None 30. Other Comments: Alternate Materials&Methods TVF&R Use Only Inspected By: Date No.Attachments Reviewed By: Date Updated JI